key: cord-0896316-wtjhyppp authors: Neary-Zajiczek, Lydia; Essmann, Clara; Rau, Anita; Bano, Sophia; Clancy, Neil; Jansen, Marnix; Heptinstall, Lauren; Miranda, Elena; Gander, Amir; Pawar, Vijay; Fernandez-Reyes, Delmiro; Shaw, Michael; Davidson, Brian; Stoyanov, Danail title: Stain-free identification of tissue pathology using a generative adversarial network to infer nanomechanical signatures date: 2021-09-02 journal: Nanoscale advances DOI: 10.1039/d1na00527h sha: 61fa3a7dc1dc7cff0674534d6483f14161dfc704 doc_id: 896316 cord_uid: wtjhyppp Intraoperative frozen section analysis can be used to improve the accuracy of tumour margin estimation during cancer resection surgery through rapid processing and pathological assessment of excised tissue. Its applicability is limited in some cases due to the additional risks associated with prolonged surgery, largely from the time-consuming staining procedure. Our work uses a measurable property of bulk tissue to bypass the staining process: as tumour cells proliferate, they influence the surrounding extra-cellular matrix, and the resulting change in elastic modulus provides a signature of the underlying pathology. In this work we accurately localise atomic force microscopy measurements of human liver tissue samples and train a generative adversarial network to infer elastic modulus from low-resolution images of unstained tissue sections. Pathology is predicted through unsupervised clustering of parameters characterizing the distributions of inferred values, achieving 89% accuracy for all samples based on the nominal assessment (n = 28), and 95% for samples that have been validated by two independent pathologists through post hoc staining (n = 20). Our results demonstrate that this technique could increase the feasibility of intraoperative frozen section analysis for use during resection surgery and improve patient outcomes. Repeat following code for p of R measured samples: • Wp, 1 ≤ p ≤ R: Whole-sample grayscale microscopy image of pth liver tissue sample • p W T (x, y) refers to the joint probability mass function (PMF) of W and T and is equivalent to computing the joint histogram of image intensity W and tissue topology T , or more generally, the co-occurrence matrix • p W (x, y) and p T (x, y) are the marginal PMFs of W and T , respectively, and are equivalent to computing the normalized histograms of image intensity W and tissue topology T set of N training pairs of microscopy images Z ′′ and elastic modulus maps EM ′ extracted from pth tissue sample Tissue Contact Area of 10 µm Diameter Bead Fig. S2a shows the calculation of the tissue contact area A of the 10 µm diameter bead at an indentation depth z. Figs. S2b and c compare the contact area to the size of the measurement grid for (b) an average indentation depth of 2 µm, which is 50 µm 2 , and (c) at the maximum indentation depth of 3 µm (63 µm 2 ). While some measurement locations overlap, we found that using a fine (oversampled) measurement spacing allowed us to record a large number of force-indentation curves to better characterize each measurement area. It was not always possible to record a measurement at each point in the sampling grid due to a number of factors, including structural degradation or detached tissue, air bubbles or height differences beyond the retraction range of the cantilever. The large contact area and oversampled measurement spacing influenced the design of the prediction architecture, which used input image patches that were double the size of the output EM maps (64 × 64 pixels 20 µm × 20 µm in size vs. 32 × 32 pixels 10 µm × 10 µm in size). Fig. S3 shows an illustration of the EM prediction process using the trained GAN described in the main text. The mismatch in size of the training patches and in the structure of the generator U-Net required overlapping input patches to be extracted from the input image (using the extract_image_patches function in the Tensorflow library) to generate a contiguous EM prediction for the entire sample on a pixelwise basis. The input image is zero-padded at the edges to account for the mismatch in size. The output of the extract_image_patches function (stacks of overlapping patches) could not be passed directly to the existing Keras prediction model and thus was not parallelized, meaning the individual patches were predicted on sequentially, contributing to the significant processing time required to predict on a single input image (approximately 15 minutes on a NVIDIA Tesla V100 with 32 GB of onboard memory for a typical image 11.4 MB and 3744 x 3216 pixels in size). Future work would involve fully parallelizing and optimizing the algorithm. Fig. S4a shows the prediction mask area for sample G245-17-01 which ignores out-of-focus material such as that on the right-hand side of the sample as such material caused the network to output spurious EM values. The post hoc stained sample shown in Fig. S4b was classified by one pathologist as fibrotic with likely adenocarcinoma on the right-hand side, where the stained tissue appears to have come away from the slide. The sample was classified as "No Tumour" as the prediction area only contains fibrotic tissue. Fig. S5 shows two samples of nominally different tissue types. Sample G209-05-02 was nominally classified as "Tumour", however histopathological assessment (Figs. S5c and f) confirmed that no cancerous tissue was present in either of the sections. Sample G209-06-02 was nominally and histopathologically classified as "No tumour". The predicted distributions of elastic modulus values are almost identical for the two samples; both were correctly classified by the algorithm as "No tumour". Summary of all measured samples: nominal tissue type, pathologist assessment, assigned label, predicted cluster, posterior probability of sample belonging to predicted cluster, and classification score. Computer Vision, Graphics, and Image Processing