key: cord-0892935-no4bjpdr authors: Zhang, Nuo; Feng, Jinhui; Zhao, Guanhui; Duan, Xiaoyi; Wang, Yaoguang; Zhang, Daopeng; Wei, Qin title: Ultrasensitive Photochemical Immunosensor Based on Flowerlike SnO(2)/BiOI/Ag(2)S Composites for Detection of Procalcitonin date: 2021-10-28 journal: Biosensors (Basel) DOI: 10.3390/bios11110421 sha: f838560fa489adffe2a91e469e5c8b950e266f37 doc_id: 892935 cord_uid: no4bjpdr Based on the necessity and urgency of detecting infectious disease marker procalcitonin (PCT), a novel unlabeled photoelectrochemical (PEC) immunosensor was prepared for the rapid and sensitive detection of PCT. Firstly, SnO(2) porous nanoflowers with good photocatalytic performance were prepared by combining hydrothermal synthesis and calcining. BiOI nanoflowers were synthesized by facile ultrasonic mixed reaction. Ag(2)S quantum dots were deposited on SnO(2)/BiOI composites by in situ growth method. The SnO(2)/BiOI/Ag(2)S composites with excellent photoelectric properties were employed as substrate material, which could provide significantly enhanced and stable signal because of the energy level matching of SnO(2), BiOI and Ag(2)S and the good light absorption performance. Accordingly, a PEC immunosensor based on SnO(2)/BiOI/Ag(2)S was constructed by using the layered modification method to achieve high sensitivity analysis of PCT. The linear dynamic range of the detection method was 0.50 pg·mL(−1)~100 ng·mL(−1), and the detection limit was 0.14 pg·mL(−1). In addition, the designed PEC immunosensor exhibited satisfactory sensitivity, selectivity, stability and repeatability, which opened up a new avenue for the analyzation of PCT and further provided guidance for antibiotic therapy. Due to its high accuracy for the diagnosis of bacterial infections, procalcitonin (PCT) is an FDA-approved blood infection marker for guiding antibiotic therapy [1, 2] . In normal human serum, the level of PCT is less than 0.1 ng·mL −1 [3] . When the human body suffers from bacteria, fungi, or parasites and more severe sepsis or multiple organ failure, the level of PCT increases sharply. When PCT concentration in serum exceeds 0.5 ng·mL −1 , the antibiotic therapy will be strongly recommended [4] . Research shows that elevated serum PCT is frequently seen in sepsis, severe trauma, heatstroke, necrotizing fasciitis, urinary tract infection, lower respiratory tract infections, neoplastic diseases and so on [5] . Some evidence also supports that PCT is also a new biomarker for the cardiologist [6] . In addition, PCT may be an indicator of disease severity in COVID-19 and may contribute to determine the severity of patients infected with SARS-CoV-2, thus playing an important role in COVID-19 antimicrobial stewardship [7, 8] . Therefore, exploring an accurate, sensitive, simple and rapid determination method of PCT level in human blood serum is quite important for the early diagnosis of inflammation and other diseases, further guiding the antibiotic therapy. Up to now, many detection methods based on immunoassay have been developed for PCT determination; for instance, enzyme-linked immunosorbent assay [9] , chemiluminescence immunoassay [10, 11] , electrochemical immunoassay [12] [13] [14] , microfluidics immunoassays [15] , fluorescence immunoassay [16] , lateral flow immunoassays [17] , surface plasma resonance immunoassay [18] , photoelectrochemical (PEC) immunosensor [19, 20] and so on. Compared with other methods, PEC immunosensors have excellent features of high signal-to-noise ratio, simple operation, needlessness of expensive maintenance and easy miniaturization because of the dual advantages of optical and electrochemical methods. It is worth mentioning that label-free PEC immunosensors do not need complex labeling steps for the detected objects, which can save time, improve reproducibility and maintain the intrinsic characteristics of the objects. As is known to all, the new photoelectrical sensing material plays an important role in the construction of the sensor [21, 22] . Especially, metal oxide nanomaterials have good photoelectric and photocatalytic properties, which have been widely used in the field of PEC immunosensors. Among many oxide semiconductors, stannic oxide (SnO 2 ) is one of the most representative semiconductor materials because of its unique catalytic and electrochemical properties, which has been widely applied in various domains including lithium-ion battery, solar cells, photocatalyst, photodetection and gas sensors [23] [24] [25] [26] [27] . A different morphology of SnO 2 can be obtained by different synthesis methods and reaction conditions, such as nanoparticles, nanorods, nano-microspheres, nanoflowers and other microstructures. Flowerlike SnO 2 is in favor of surface reaction and can enhance the sensing performances due to its structure configuration. Nonetheless, the wide band gap of SnO 2 (Eg = 3.6 eV) leads to the poor light absorption properties and high electron-hole recombination. In order to improve the photocurrent conversion efficiency of SnO 2 , two basic approaches should be considered: one is to add the active sites of SnO 2 by designing reasonable structure, and another is to build the heterostructure of SnO 2 nanocomposites to promote charge separation effectively. Environmentally friendly bismuth-based materials have attracted people's great attention because of their special layered structure and excellent photocatalytic performance [28] . Among these materials, bismuth oxyiodide (BiOI) is a well-known layered p-type semiconductor (Eg = 1.7~1.9 eV), which has been widely used in the field of photocatalysis and pharmaceutical materials recently [29] [30] [31] . BiOI has strong absorption in the visible region and the alternates [Bi 2 O 2 ] 2+ layer and double I-layer can promote separation efficiency of photo-induced electrons and holes [32, 33] . Through construction SnO 2 /BiOI heterojunction, excellent photocatalytic activity and efficient sunlight-harvesting nature can be realized. In addition, Ag 2 S nanoparticles with a narrower band gap (~1.0 eV) have also attracted great interests in the field of photocatalysis because of their excellent properties such as excellent stability, good electron transfer efficiency and prominent absorption coefficient, which are commonly employed in PEC fields [34] . With its good sensitization, Ag 2 S can be modified on the SnO 2 /BiOI electrode to further improve the photoelectric properties of the substrate material. Herein, based on SnO 2 /BiOI/Ag 2 S nanocomposites, an ultrasensitive PEC immunosensor was developed for detection of PCT. Firstly, SnO 2 /BiOI/Ag 2 S composites were modified onto the ITO electrode, which can improve the sensitivity because of the high initial signal. SnO 2 and BiOI can form N-P heterojunction with good photoactivity, and with the sensitization of Ag 2 S nanoparticles, the photocurrent response enhanced significantly. Secondly, anti-PCT and PCT were immobilized on the modified electrode by the reaction between carbonyl and amino groups and antibody-antigen specific recognition, respectively. Anti-PCT and PCT can generate a hydrophobic and insulating layer on the electrode surface, resulting in decrease of electron transfer and photocurrent intensity. According to the relationship between PCT concentration and photoelectric signal, the content of PCT in the unknown sample can be calculated. PCT and anti-PCT were purchased from Linc-Bio Science Co., Ltd. (Shanghai, China). Indium tin oxide (ITO) glasses were obtained from Zhuhai Kaivo Electronic Components Co., Ltd. (Zhuhai, China) and cut into small pieces with a size of 2.5 × 1.0 cm 2 . ITO glasses were successively washed in acetone, ultrapure water, ethanol and ultrapure water under ultrasound before being used as working electrode. Other materials and instruments used are described in detail in the support materials. Flowerlike SnO 2 was prepared by the reported method [35] . Briefly, 0.016 g of thioacetamide and 7 µL of anhydrous SnCl 4 were added into a stainless-steel high-pressure reactor containing 10 mL of isopropanol. The mixture was ultrasonicated until completely dissolved. Then, the mixture was heated at 180 • C for 24 h and cooled naturally. Then, the products SnS 2 were rinsed and dried and then calcined at 500 • C for 2 h in a muffle to obtain mesoporous SnO 2 . According to the literature [33] , 1.0 mmol of KI was dissolved in 60 mL ultrapure water under stirring for 40 min. Then, 1.0 mmol of Bi(NO 3 ) 3 ·5H 2 O were added slowly drop by drop and treated with ultrasonic for at least 15 min. Subsequently, the mixtures were continuously stirred for about 3 h to obtain orange yellow powder. Finally, after washing and purification, the product BiOI was dried at 60 • C. Typically, 6 µL of SnO 2 was dropped onto a piece of clean ITO and dried at room temperature. Then, 6 µL of BiOI aqueous solution with the concentration of 5 mg·mL −1 was coated on the surface of the ITO/SnO 2 . After being dried, the as-prepared ITO/SnO 2 /BiOI electrode was successively soaked 3 min for each step in 0.1 mol·L −1 AgNO 3 solution in alcohol and 0.1 mol·L −1 Na 2 S in methanol aqueous solution (V/V = 1:1). Through this process, Ag 2 S was deposited on SnO 2 /BiOI composites by in situ growth method. Thereafter, 4 µL of thioglycolic acid (TGA) (3 mmol·L −1 ) was added on its surface, and then 6 µL of anti-PCT solution (1 µg·mL −1 ) was attached to the modified electrode. Subsequently, 4 µL of 0.1% BSA was used to block the unbound sites. At last, 6 µL of PCT solution with different concentrations was dropped onto the electrode and incubated with anti-PCT. The fabrication process of the immunosensor is shown in Figure 1 . In this experiment, PEC detection was performed in PBS solution containing ascorbic acid (AA) and the light source used was LED lamp (working voltage was 36 V and oper- In this experiment, PEC detection was performed in PBS solution containing ascorbic acid (AA) and the light source used was LED lamp (working voltage was 36 V and operating current was 0~3.5 A). According to the relationship between the photocurrent intensity and the concentration of PCT, the quantitative PCT detection can be realized. The morphology of SnO 2 , BiOI, SnO 2 /BiOI and SnO 2 /BiOI/Ag 2 S was characterized by scanning electron microscopy (SEM). According to Figure 2A ,B, it can be seen that both SnO 2 and BiOI showed a flower structure composed of thin nanosheets with a size of about 2~3 µm, which could provide a large surface area for loading of more excellent performance of nanoparticles. Although both were flower-like structures, the pieces that make up the flower were not the same. In addition, in the atomic number contrast image, regions with large average atomic numbers were brighter than regions with small atomic numbers. According to the contrast of the sample with different atomic number, the morphology of the two samples can be clearly distinguished ( Figure 2C ). After SnO 2 /BiOI composites were successfully coated on the ITO electrode, Ag 2 S nanoparticles were uniformly deposited on its surface as sensitizer, which is shown in Figure 2D . We can see that the lamellar structure that made up the flower became thick due to the deposition of Ag 2 S. The element composition of the composites was measured with EDS spectrum, as shown in Figure S1 . It can be seen that Sn, O, Bi, I, S and Ag elements were clearly observed, which further proved Ag 2 S was successfully fixed on the surface of SnO 2 /BiOI to obtain SnO 2 /BiOI/Ag 2 S composites. Furthermore, the EDS mapping images further confirmed the homogenous distribution. Figure S2 shows the absorption of ultraviolet and visible light by the as-prepared SnO2, SnO2/BiOI and SnO2/BiOI/Ag2S composites. The absorption wavelength of SnO2 was less in the visible region, which was ascribed to its wide band gap. However, SnO2 could be coupled with BiOI, which resulted in the absorption peak shifting red, and the absorption peak became wider with strong absorption at 400~600 nm. Then, modification of Ag2S on the above electrode could improve the broad absorption in visible light obviously, further noticeably enhancing the photocurrent effect as expected. Observed from Figure S3 the photocurrent of SnO2/BiOI/Ag2S can be up to 93 μA, while SnO2, BiOI, SnO2/BiOI Figure S2 shows the absorption of ultraviolet and visible light by the as-prepared SnO 2 , SnO 2 /BiOI and SnO 2 /BiOI/Ag 2 S composites. The absorption wavelength of SnO 2 was less in the visible region, which was ascribed to its wide band gap. However, SnO 2 could be coupled with BiOI, which resulted in the absorption peak shifting red, and the absorption peak became wider with strong absorption at 400~600 nm. Then, modification of Ag 2 S on the above electrode could improve the broad absorption in visible light obviously, further noticeably enhancing the photocurrent effect as expected. Observed from Figure S3 , the photocurrent of SnO 2 /BiOI/Ag 2 S can be up to 93 µA, while SnO 2 , BiOI, SnO 2 /BiOI, SnO 2 /Ag 2 S, BiOI/Ag 2 S was 0.6 µA, 4 µA, 60 µA, 50 µA and 5 µA, respectively. Therefore, we selected SnO 2 /BiOI/Ag 2 S composites as the substrate material because of its excellent photoelectric property in this study. About the electron transfer mechanism, we suspected that SnO 2 , BiOI and Ag 2 S could form cascade band-edge levels because their energy bands were well matched (Figure 3) , which promoted the separation of photogenic electrons and photogenic holes, resulting in ultrafast transfer of charge. In addition, the composite material has better light absorption in the visible region, resulting in a favorable utilization rate of solar energy. SnO2, SnO2/BiOI and SnO2/BiOI/Ag2S composites. The absorption wavelength of SnO less in the visible region, which was ascribed to its wide band gap. However, SnO2 be coupled with BiOI, which resulted in the absorption peak shifting red, and the ab tion peak became wider with strong absorption at 400~600 nm. Then, modification of on the above electrode could improve the broad absorption in visible light obviously ther noticeably enhancing the photocurrent effect as expected. Observed from Figu the photocurrent of SnO2/BiOI/Ag2S can be up to 93 μA, while SnO2, BiOI, SnO2 SnO2/Ag2S, BiOI/Ag2S was 0.6 μA, 4 μA, 60 μA, 50 μA and 5 μA, respectively. Ther we selected SnO2/BiOI/Ag2S composites as the substrate material because of its exc photoelectric property in this study. About the electron transfer mechanism, we susp that SnO2, BiOI and Ag2S could form cascade band-edge levels because their energy b were well matched (Figure 3) , which promoted the separation of photogenic electron photogenic holes, resulting in ultrafast transfer of charge. In addition, the composit terial has better light absorption in the visible region, resulting in a favorable utiliz rate of solar energy. The photocurrent variation trends of the modified electrodes are shown in Figure 4A , and the enlarged view of curve a and b is shown in Figure S4 . After layer-by-layer modification, the photocurrent signal generated by the SnO 2 /BiOI/Ag 2 S modified electrode was significantly increased up to 104 µA (curve d), which was much higher than that of SnO 2 and SnO 2 /BiOI (0.6 µA of SnO 2 and 60 µA of SnO 2 /BiOI, curve b and c). This further confirmed the successful modification of Ag 2 S nanocomposites on the electrode surface. After the incubation of anti-PCT (curve g) and PCT (curve i) were modified onto the electrode in sequence, the photocurrents reduced from 45 µA to 20 µA. Part of the reason is that bioactive substances such as PCT, BSA and anti-PCT were insulating. Besides this, the increase in steric hindrance would block part of electron transfer to the photoactive substrate, leading to a gradual decline of photocurrent. Electrochemical impedance spectroscopy (EIS) was applied to further analyze the interfacial properties of the proposed immunosensor, as shown in Figure 4B . The electrontransfer resistance (R et ) value of ITO was small on account of the low electron transfer resistance (curve a). After the stepwise modification with SnO 2 (curve b), BiOI (curve c), Ag 2 S (curve d), anti-PTC (curve g), BSA (curve h) and PCT (curve i), the R et value changed significantly, which clearly verified the successful assembly process of the PEC immunosensor for PCT determination. transfer resistance (Ret) value of ITO was small on account of the low elec resistance (curve a). After the stepwise modification with SnO2 (curve b), B Ag2S (curve d), anti-PTC (curve g), BSA (curve h) and PCT (curve i), the Ret v significantly, which clearly verified the successful assembly process of munosensor for PCT determination. The concentration of substrate material (SnO2, BiOI and AgNO3), the p concentration of AA and the light intensity are some essential experimental tors. From Figure 5A , we can see that when the concentration of SnO2 wa probably blocked some of the electron transport. Hence, the SnO2 concen mg·mL −1 was used in this study. Similarly, the optimal concentration of BiO was 5.0 mg·mL −1 and 0.10 mol·L −1 (Figure 5B,C) . As shown in Figure 5D , pH lected as the best concentration. At this condition, the immobilized protein h est activity. According to Figure 5E , when the concentration of AA was to holes will be captured and there will be more electron-hole complexes in th the photocurrent signal was small. However, when the concentration of AA tion was too high, the light intensity reaching the electrode surface decreas absorption of the light intensity itself, making the excitation efficiency of A thus reducing the photocurrent signal of the whole system [36] . Therefore, 0 AA was chosen as the appropriate concentration in this system. Last but not photocurrent intensity increased with the increasing of the light intensity a The concentration of substrate material (SnO 2 , BiOI and AgNO 3 ), the pH value, the concentration of AA and the light intensity are some essential experimental influence factors. From Figure 5A , we can see that when the concentration of SnO 2 was too high, it probably blocked some of the electron transport. Hence, the SnO 2 concentration of 3.0 mg·mL −1 was used in this study. Similarly, the optimal concentration of BiOI and AgNO 3 was 5.0 mg·mL −1 and 0.10 mol·L −1 (Figure 5B,C) . As shown in Figure 5D , pH 7.4 was selected as the best concentration. At this condition, the immobilized protein had the greatest activity. According to Figure 5E , when the concentration of AA was too low, fewer holes will be captured and there will be more electron-hole complexes in the system, so the photocurrent signal was small. However, when the concentration of AA in the solution was too high, the light intensity reaching the electrode surface decreased due to the absorption of the light intensity itself, making the excitation efficiency of Ag 2 S decrease, thus reducing the photocurrent signal of the whole system [36] . Therefore, 0.12 mol·L −1 of AA was chosen as the appropriate concentration in this system. Last but not the least, the photocurrent intensity increased with the increasing of the light intensity and reached a platform when the working current of LED lights was 3.0 A, which was selected as the optimal light intensity current in this experiment, as shown in Figure 5F . platform when the working current of LED lights was 3.0 A, which was selected as the optimal light intensity current in this experiment, as shown in Figure 5F . Under the above optimal experimental conditions, the detection of PCT was realized on the change of photocurrent intensity of the substrate materials, which attributed to the immunoreactions between PCT and anti-PCT and the changes of PCT concentration. According to Figure 6A , the photocurrent density and the logarithmic values of concentration of PCT had a good linear relationship with the range from 0.50 pg·mL −1 to 100 ng·mL −1 . The linear equation was I = 17.65-6.02 lg cPCT with a correlation coefficient of 0.9921 ( Figure 6B ). The limit of detection for PCT concentration was calculated to be 0.14 pg·mL −1 (S/N = 3). As shown in Table S1 , the PEC immunosensor we constructed had a lower detection limit and a wider linear range than some other reported methods for the detection of PCT, for example, chemiluminescence immunoassay, electrochemical immunosensor, immunochromatographic assay, immunosorbent assay, time-resolved digital immunoassay and electrochemical paper-based analysis, but it was slightly inferior to electrochemiluminescence immunosensor. Compared with other existing PEC immunosensors, the as-prepared immunosensor still showed a satisfying performance in sensitivity and linear range. Under the above optimal experimental conditions, the detection of PCT was realized on the change of photocurrent intensity of the substrate materials, which attributed to the immunoreactions between PCT and anti-PCT and the changes of PCT concentration. According to Figure 6A , the photocurrent density and the logarithmic values of concentration of PCT had a good linear relationship with the range from 0.50 pg·mL −1 to 100 ng·mL −1 . The linear equation was I = 17.65-6.02 lg c PCT with a correlation coefficient of 0.9921 ( Figure 6B ). The limit of detection for PCT concentration was calculated to be 0.14 pg·mL −1 (S/N = 3). As shown in Table S1 , the PEC immunosensor we constructed had a lower detection limit and a wider linear range than some other reported methods for the detection of PCT, for example, chemiluminescence immunoassay, electrochemical immunosensor, immunochromatographic assay, immunosorbent assay, time-resolved digital immunoassay and electrochemical paper-based analysis, but it was slightly inferior to electrochemiluminescence immunosensor. Compared with other existing PEC immunosensors, the as-prepared immunosensor still showed a satisfying performance in sensitivity and linear range. Biosensors 2021, 11, x FOR PEER REVIEW 8 of 10 The repeatability, stability and specificity of biosensors are important indexes to measure the actual performance of biosensors. The excellent repeatability is a prerequisite for accuracy. From Table S2 , we can see that the relative standard deviation (RSD) of eleven parallel measurements was in the range of 2.2~8.4%, which demonstrated good repeatability. The stability is critical to sensors. From Figure S5A , the photocurrent intensity was recorded with 16 light on/off cycles of incubation with 0.1 ng·mL −1 of PCT. There was no distinct change of photocurrent intensity value, indicating the prepared PEC immunosensor possessed the satisfactory stability for PCT detection. To evaluate the specificity of the immunosensor for PCT, 100 ng·mL −1 of two typical interfering antigens, carcinoembryonic antigen (CEA) and prostatic specific antigen (PSA), were selected for interference test by mixing with 1.0 ng·mL −1 of PCT. According to Figure S5B , there was no obvious change of the photocurrent response in the case of the addition of CEA and PSA, which indicated that the satisfactory specificity. To verify the viability of the PEC immunosensor for PCT detection in practical blood samples, the recovery experiments were carried out through adding different PCT standard solution to human serum samples. According to Table S2 , we can see that the recoveries of the samples were in the range of 98.8~103%, and the RSD was in the range of 2.2~8.4%, which indicated the promising potential for the analyzation of PCT in the human blood serum samples. In this study, based on the good photoelectric performance of SnO2/BiOI/Ag2S composites, a novel unlabeled PEC immunosensor was successfully constructed for PCT detection. The application of SnO2 in immunosensing analysis is still less, and SnO2 was a perfect substrate for PEC immunosensors due to its good stability on ITO electrode. Through construction SnO2/BiOI heterojunction, excellent photocatalytic activity and efficient sunlight-harvesting nature can be realized, and flower-like SnO2 and BiOI can provide large surface area for the loading of Ag2S and further sensitize to the photocurrent response. Under the optimal experimental detection conditions, the proposed immunosensor had a detection limit of 0.14 pg·mL −1 for PCT detection, and the linear range was 0.50 pg·mL −1~1 00 ng·mL −1 , which showed a satisfying performance compared with some other reported methods. It is worth mentioning that SnO2/BiOI/Ag2S composites had some advantages such as convenient synthesis, low cost, excellent photoelectric performance and environmental friendliness, which have potential applications in the field of photoelectrocatalysis, photoelectric device research and so on. The repeatability, stability and specificity of biosensors are important indexes to measure the actual performance of biosensors. The excellent repeatability is a prerequisite for accuracy. From Table S2 , we can see that the relative standard deviation (RSD) of eleven parallel measurements was in the range of 2.2~8.4%, which demonstrated good repeatability. The stability is critical to sensors. From Figure S5A , the photocurrent intensity was recorded with 16 light on/off cycles of incubation with 0.1 ng·mL −1 of PCT. There was no distinct change of photocurrent intensity value, indicating the prepared PEC immunosensor possessed the satisfactory stability for PCT detection. To evaluate the specificity of the immunosensor for PCT, 100 ng·mL −1 of two typical interfering antigens, carcinoembryonic antigen (CEA) and prostatic specific antigen (PSA), were selected for interference test by mixing with 1.0 ng·mL −1 of PCT. According to Figure S5B , there was no obvious change of the photocurrent response in the case of the addition of CEA and PSA, which indicated that the satisfactory specificity. To verify the viability of the PEC immunosensor for PCT detection in practical blood samples, the recovery experiments were carried out through adding different PCT standard solution to human serum samples. According to Table S2 , we can see that the recoveries of the samples were in the range of 98.8~103%, and the RSD was in the range of 2.2~8.4%, which indicated the promising potential for the analyzation of PCT in the human blood serum samples. In this study, based on the good photoelectric performance of SnO 2 /BiOI/Ag 2 S composites, a novel unlabeled PEC immunosensor was successfully constructed for PCT detection. The application of SnO 2 in immunosensing analysis is still less, and SnO 2 was a perfect substrate for PEC immunosensors due to its good stability on ITO electrode. Through construction SnO 2 /BiOI heterojunction, excellent photocatalytic activity and efficient sunlight-harvesting nature can be realized, and flower-like SnO 2 and BiOI can provide large surface area for the loading of Ag 2 S and further sensitize to the photocurrent response. Under the optimal experimental detection conditions, the proposed immunosensor had a detection limit of 0.14 pg·mL −1 for PCT detection, and the linear range was 0.50 pg·mL −1~1 00 ng·mL −1 , which showed a satisfying performance compared with some other reported methods. It is worth mentioning that SnO 2 /BiOI/Ag 2 S composites had some advantages such as convenient synthesis, low cost, excellent photoelectric performance and environmental friendliness, which have potential applications in the field of photoelectrocatalysis, photoelectric device research and so on. The following are available online at https://www.mdpi.com/article/ 10.3390/bios11110421/s1. Figure S1 : The EDS mapping images of SnO 2 /BiOI/Ag 2 S composites; Figure S2 : UV-Vis diffuse reflectance spectra of SnO 2 (a), SnO 2 /BiOI (b) and SnO 2 /BiOI/Ag 2 S (c); Figure S3 : Time-based photocurrent response curves of SnO 2 (a), BiOI(b), SnO 2 /BiOI(c), SnO 2 /Ag 2 S(d), BiOI/Ag 2 S(e) and SnO 2 /BiOI/Ag 2 S(f); Figure S4 : Time-based photocurrent response curves of ITO electrode (a) and ITO/SnO 2 (b); Figure S5 : Stability curve of chronocurrent (A); Selectivity of the PEC immunosensor for detecting PCT (B): (a) Blank, (b) Blank + 100 ng·mL −1 CEA, (c) Blank + 100 ng·mL −1 PSA, (d) 1.0 ng·mL −1 PCT, (f) 1.0 ng·mL −1 PCT + 100 ng·mL −1 CEA, (g) 1.0 ng·mL −1 PCT + 100 ng·mL −1 PSA. The applied potential was 0 V. Error bars = SD (n = 5); Table S1 : Comparison of the performance of the proposed PEC immunosensor for PCT detection and those of other reports; Table S2 : The results of the PCT determination in human serum samples. The data presented in this study are available on request from the corresponding author. The authors declare no conflict of interest. An ultrasensitive electrochemical immunosensor for procalcitonin detection based on the gold nanoparticles-enhanced tyramide signal amplification strategy Procalcitonin testing to guide antibiotic therapy in acute upper and lower respiratory tract infections Ratiometric electrochemical immunosensor for the detection of procalcitonin based on the ratios of SiO 2 -Fc-COOH-Au and UiO-66-TB complexes Accuracy of procalcitonin for sepsis diagnosis in critically ill patients: Systematic review and meta-analysis Procalcitonin levels in patients with positive blood culture, positive body fluid culture, sepsis, and severe sepsis: A cross-sectional study Procalcitonin: A new biomarker for the cardiologist Procalcitonin levels in COVID-19 patients The use of procalcitonin as an antimicrobial stewardship tool and a predictor of disease severity in coronavirus disease 2019 (COVID-19) A new ELISA for the quantification of equine procalcitonin in plasma as potential inflammation biomarker in horses Development of a novel chemiluminescence immunoassay for the detection of procalcitonin A dual-signals response electrochemiluminescence immunosensor based on PTC-DEPA/KCC-1 NCs for detection of procalcitonin Label-free electrochemical immunosensor with palladium nanoparticles functionalized MoS 2 /NiCo heterostructures for sensitive procalcitonin detection A label-free electrochemical immunosensor based on encapsulated signal molecules in mesoporous silica-coated gold nanorods for ultrasensitive assay of procalcitonin Quantitative detection of procalcitonin using an electrochemical immunosensor based on MoO 3 /Au@rGO nanocomposites Advances of microfluidic technologies applied in diagnosis and treatment of sepsis Simultaneous detection of fungal (1,3)-β-d-glucan and procalcitonin using a dual-label time-resolved fluorescence immunoassay Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay Surface plasmon resonance-based immunoassay for procalcitonin Ultrasensitive photoelectrochemical immunosensor for procalcitonin detection with porous nanoarray BiVO 4 /CuxS platform as advanced signal amplification under anodic bias A signal-off type photoelectrochemical immunosensor for the ultrasensitive detection of procalcitonin: Ru(bpy) 3 2+ and Bi 2 S 3 co-sensitized ZnTiO 3 /TiO 2 polyhedra as matrix and dual inhibition by SiO 2 /PDA-Au A novel self-enhanced carbon nitride platform coupled with highly effective dual-recycle strand displacement amplifying strategy for sensitive photoelectrochemical assay Modulating the 0D/2D Interface of Hybrid Semiconductors for Enhanced Photoelectrochemical Performances Sb-Doped SnO 2 nanorods underlayer effect to the α-Fe 2 O 3 nanorods sheathed with TiO 2 for Enhanced Self-Assembled Few-Layered MoS 2 on SnO 2 Anode for Enhancing Lithium-Ion Storage Synthesis of porous CeO 2 -SnO 2 nanosheets gas sensors with enhanced sensitivity Nanocomposites of SnO 2 and g-C 3 N 4 : Preparation, characterization and photocatalysis under visible LED irradiation Construction of complex WO 3 -SnO 2 hollow nanospheres as a highperformance anode for lithium-ion batteries Light-facilitated structure reconstruction on self-optimized photocatalyst TiO 2 @BiOCl for selectively efficient conversion of CO 2 to CH 4 Step-scheme NiO/BiOI heterojunction photocatalyst for rhodamine pho-todegradation Fabrication and characterization of Ag/BiOI/GO composites with enhanced photocatalytic activity Recent progress on bismuth oxyiodide (BiOI) photocatalyst for environmental remediation Visible-light-driven photoelectrochemical sensing platform based on BiOI nanoflowers/TiO 2 nanotubes for detection of atrazine in environmental samples Label-free photoelectrochemical immunoassay for CEA detection based on CdS sensitized WO 3 @BiOI heterostructure nanocomposite A novel sandwich-type photoelectrochemical sensor for SCCA detection based on Ag 2 S-sensitized BiOI matrix and Au core Pd shell nanoflower label for signal amplification Hierarchical mesoporous SnO 2 Nanosheets on carbon cloth: A robust and flexible electrocatalyst for CO 2 reduction with high efficiency and selectivity Ultrasensitive photoelectrochemical immunosensor for the detection of amyloid β-protein based on SnO 2 /SnS 2 /Ag 2 S nanocomposites