key: cord-0892206-t1g4ah3c authors: George, Leah R.; George, Smitha E.; Dhawan, Ira; Babu, Malavika; Sahajanandan, Raj; Joselyn, Anita S. title: Simulation with a colour indicator to help reduce contamination during airway management in COVID-19 times: An experience from a tertiary centre in India date: 2021-11-23 journal: Indian J Anaesth DOI: 10.4103/ija.ija_768_21 sha: 742825794f348307b3173e543b9f40698195fe31 doc_id: 892206 cord_uid: t1g4ah3c BACKGROUND AND AIMS: The coronavirus disease 2019 (COVID-19) pandemic has initiated modified protocols for aerosol-generating procedures. A simulation study using dye was conducted to highlight contamination at intubation and extubation and to encourage adherence to the new COVID-19 protocol among anaesthesia personnel in our institution. METHODS: A video demonstrating the new COVID-19 protocols was circulated in the Department of Anaesthesiology a week prior to the study. Thirty teams, each comprising an anaesthesia resident and a staff technician, were enroled. Each team was asked to demonstrate the steps of preparation, intubation and extubation on a mannequin in a COVID-19 scenario. Checklists were used to assess points of contamination and adherence to the protocols. Following debriefing, a repeat simulation was conducted. The use of a dye highlighted the points of contamination. The study subjects provided feedback on the usefulness of the session and practical difficulties encountered in adapting to the new protocols. RESULTS: The average contamination scores decreased by 3.4 (95% confidence interval (CI): 2.4–4.4, P < 0.001) in the post-debrief session. Adherence to the steps of the modified protocol improved by a score of 2.7 (CI: 3.6–1.83) among anaesthesiologists and by 4.3 (CI: 5.3–3.3) among technicians. Further, 93% felt that the use of the colour indicator reinforced awareness of the possible points of contamination. CONCLUSION: Simulation with a low-fidelity mannequin by using colour indicator for secretions is an effective teaching tool to reduce health hazards during airway management in COVID-19 times. simulation techniques can facilitate familiarity and identify practical problems of implementation. [6] This study devised for anaesthesia personnel used a dye to highlight secretions. As airway secretions and aerosols are colourless, anaesthesia personnel can easily be caught off guard during airway management. The aim of the study was to impress upon the study participants the potential points of contamination and the need to follow the new protocols that focus on decreasing contamination and aerosolisation to create a safer work environment. The primary objective was to assess the points of contamination and adherence rate among study participants to the newly formulated department protocol in the baseline (pre debrief) and post debrief session by using a colour indicator as a teaching tool. A secondary objective was to assess the practical difficulties faced by the anaesthesia residents and staff anaesthesia technicians in following these revised protocols. A quasi-experimental study was conducted in the Department of Anaesthesiology in a tertiary care, teaching hospital in India. Approval was obtained from the institute's review board and ethics committee. Written consent was obtained from all the participants to publish the data obtained. This manuscript follows STROBE guidelines. Our department conducts approximately 48,000 anaesthetics annually, and we have a workforce of more than 160 anaesthesia personnel. This simulation study was conducted over 4 days in the operation theatre. The inclusion criteria were current second and third-year anaesthesia residents and staff anaesthesia technicians with at least 1 year of work experience. At the outset of the COVID-19 pandemic, a department protocol was developed for airway management according to the available evidence. [3, 7, 8] The staff and students were familiarised with these new concepts through group discussions on Microsoft teams. Based on this protocol, a video was made demonstrating the correct sequences and steps at intubation and extubation. This video was circulated to all members of the anaesthesia department a week prior to the study and was part of routine dissemination of COVID-19 information. The participants were unaware that a study would be conducted. On the day of the simulation, all anaesthetic drugs and equipment, including the newer equipment designed specifically for use in the COVID-19 scenario, were kept available in the OR. A low-fidelity mannequin (Laerdal airway management trainer) was used. To simulate secretions, a mannequin compatible dye (Laerdal polyethylene glycol) [ Figure 1a ] was used to stain the oral cavity and was sprayed to simulate coughing during extubation. An ampoule with the dye was placed in the oral cavity of the mannequin to simulate secretions for suctioning. Personal protective equipment (PPE), specifically N95 masks, gloves, gowns, head hoods, visors and goggles, were placed at the site of simulation. All equipment and reusable PPE were thoroughly cleaned between each simulation run. Strict COVID-19 protocols such as physical distancing, mandatory use of N 95 masks and use of hand hygiene by both participants and assessors were followed. [9] Each team comprised an anaesthesia resident and a staff anaesthesia technician. The team was given a scenario of an elective surgery where the patient had to be given general anaesthesia. They were asked to demonstrate preparation for the case, steps of intubation and extubation in the context of the current COVID-19 scenario. One of the investigators played the role of a first-year resident who would do as instructed by the team (example: drug administration). The domains assessed were points of contamination (POCs) and steps of protocol (SOPs) for the anaesthesiologists and for technicians, respectively. Assessment was done by three independent observers by using checklists. The participants were unaware of what was being observed and assessed. Once the baseline simulation run was over, the subjects were shown the areas of staining by the dye [ Figure 1b ], which reflected the points of contamination. A verbal debrief on their performance was done and they were asked to review the department protocol video on their mobile phones. Following this, a post-debrief simulation and assessment were repeated. Participants were asked to maintain the confidentiality of the study. There were 20 potential POCs, each given a score of 1. There were 20 SOPs for the residents and the technicians, respectively, with a maximum score of 20 each. For residents, this score comprised 2 points for preparation, 10 points for intubation and 8 points for extubation [Annexure 1]. For technicians, it was 4 points for preparation, 10 for intubation and 6 for extubation [Annexure 2]. Data were noted in the data collection forms and collated in Microsoft Excel. The primary outcomes assessed were the average contamination rate of the anaesthesia working space in the operating room (OR) and adherence rate to SOP during intubation and extubation of the mannequin at the baseline simulation and at the post-debrief simulation. At the end of the latter, feedback regarding the session and practical difficulties encountered in the OR was obtained from the participants. This feedback, in the form of 11 questions, was answered in the Likert scale format. The two domains that were statistically analysed were the POCs and SOPs, with scores ranging from 0 to 20 each. Descriptive measures such as mean with standard deviation and/or median with interquartile range were measured for all continuous baseline variables, whereas frequencies and percentages were presented for all baseline categorical variables. Summative score for each domain was calculated. Paired t test was used to find the changes in scores of both domains before and after the intervention if data followed normal distribution. If data were not normally distributed, the corresponding non-parametric method, that is, Wilcoxon signed-rank test was used. The mean change, with bootstrapped 95% confidence interval (CI) was presented, if normal. Correlation analysis was also done to find the relationship between SOP and POC scores before and after intervention. Stratum-specific analysis was also presented. Unadjusted and adjusted analyses were carried out. Data were analysed using Statistical Package for Social Sciences for Windows (SPSS Inc. Released 2007, version 23.0. Armonk, New York, USA). The average contamination rate of the anaesthesia workspace in a simulation study by Birnbach et al. [10] was reported as 20.3 (SD ± 9) out of the 40 possible contamination sites. To aim for a 50% reduction with alpha error at 1% and beta error at 10%, we needed to study 25 subjects. Considering a potential dropout rate of 10%, we studied 30 teams. The total number of teams were 30, with a resident and a technician in each team [ Figure 2 ]. We found an average contamination rate of 7.03 out of 20 in the baseline simulation that decreased to 3.6 in the post-debrief simulation. The scores for steps of protocol improved from the baseline by 2.7 in anaesthesia residents and by 4.3 in technicians [ Table 1 ]. The most common SOP not adhered to among anaesthesiologists was switching off the oxygen flows during airway management [ Figure 3 ]. During intubation and extubation, 63.3% of residents (19 out of 30) failed to switch off oxygen, which decreased to 23.3% (7 out of 30) during the post-debrief session. The most common SOP not adhered to by anaesthesia technicians was connecting the suction catheter. We found that only 40% of technicians connected suction catheter pre-debrief which improved significantly to 73.3% in the post-debrief session. The points with the highest contamination rates were the laryngoscope handle, facemask, bed linen, heat and moisture exchanger (HME) filter and endotracheal tube [ Figure 4 ]. We analysed the correlation between adherence to SOP and reduction in POC score. Significant correlation was present in the baseline scores but not in the post-debrief scores. We analysed the baseline scores further and found that in the unadjusted analysis, for a unit increase in the SOP scores for the anaesthesiologists, there was a corresponding reduction of 0.583 (CI: −0.926 to −0.240) (P = 0.002) units in the POC score, which was statistically significant. Similarly, for the technician's score, the reduction was 0.313 (CI: −0.575 to −0.050) (P = 0.021). On adjusting for the performance of the technicians, we noted that a unit increase in the SOP score for the anaesthesiologists was associated with a reduction of 0.539 (CI: −1.034 to −0.044) (P = 0.034) units of POC, which was statistically significant [ Table 2 ]. There was no correlation between the number of times the protocol video was watched and the baseline POC scores. The mean baseline POC score was 6.4 ± 1.6 in those who had viewed it more than once compared to 7.4 ± 2.9 in those who had seen it once or never. The COVID-19 pandemic has prompted the revision of airway management protocols to minimise occupational risks. [11] [12] [13] [14] Our study, which used a dye to simulate contamination during airway management, was devised in light of this new healthcare scenario. We found a significant decrease in the points of contamination and an increased adherence to protocols in the post-debrief session. The findings of our study agree with the current literature that simulation is an excellent practice-based learning tool for acquiring familiarity in high stake situations such as COVID-19. [5, [15] [16] [17] [18] It has been invaluable in teaching ventilatory management, [6] introducing new protocols [5, 15] and assessing OR preparedness for the COVID-19 patient. [16] Prior to the pandemic too, there have been simulation studies that focused on the reduction of contamination in the OR. [10, 19] For specialities dealing with aerosol-generating procedures, these studies have taken on an urgent application. Visualisation of contamination has been shown to be a powerful learning aid for infection control. [20] In our study, the colour indicator highlighted points of contamination and the average contamination rate reduced after the subjects visualised it for themselves, emphasising that 'seeing is believing'. The residents had better baseline scores compared to the technicians. Familiarity with simulation training and access to accurate information on precautions to be taken in the COVID-19 scenario would have favoured the residents. The technicians being simulation naïve had lower baseline scores but had better improvement in mean scores at the post-debrief session. The laryngoscope handle and the face mask were universally contaminated as found in the study by Porteous et al.; [19] thus, there was no difference in baseline and post-debrief. The bed linen and head pillow had high contamination rates because the contaminated face mask was placed on the linen instead of in a disposable bag. The endotracheal tube and HME filter were the next most common sites of contamination. This highlights the need to double glove and remove the outer pair of gloves soon after intubation as suggested by Birnbach et al. [10] The non-invasive blood pressure cuff and electrocardiograph electrodes were contaminated more at extubation, emphasising the need to remove the outer pair of contaminated gloves at extubation prior to shifting the patient. We found a significant correlation between POCs and adherence to steps of protocol during the baseline simulation. In the post-debrief session, as POCs were low and the protocol was well adhered to, the correlation was not found to be significant. Further analysis of the baseline results after adjusting for the performance of technicians showed a significant correlation (P = 0.034) only for the performance of the residents. This points out that the anaesthesiologist, being the team leader, plays a major role in the extent of contamination caused. The COVID-19 crisis has provoked an 'infodemic'-a situation of an overwhelming flood of information through health organisations and governments. [21] Thus, the department protocol video may have been viewed as one among the many protocol videos in circulation. We did not find a significant correlation between the number of times the video was viewed and the baseline simulation scores. The simulation helped our participants to consciously take note of each of the steps of protocol and each potential point of contamination. We infer that the video as a sole method of teaching new practices in the COVID scenario is not as effective as when combined with simulation. The majority (93.3%) of the study participants felt that the use of a colour indicator during the simulation helped them realise the extent of contamination that happens and convinced them of the need to adhere to the protocol. A limitation of the study is that immediate recall could be one of the reasons for the good post-debrief scores. Ideally, a post-debrief session should be conducted a few weeks later. However, as this study was conducted when our country was seeing an uptick in the number of cases, we were unsure if we would get the same teams later. Another limitation is that we did not include a crisis scenario, which possibly explains the low baseline contamination. The aerosol box was used as part of the SOP as at the time of conducting this study, it was advocated as an adjunct to PPE. [22] [23] [24] Current emerging evidence on its use is conflicting. [25, 26] Provide face mask to the anaesthetist. Remove aerosol box when asked for and cleans the inside. BASELINE SCORE-POST-DEBRIEF SCORE-HME-heat and moisture exchanger, ET-endotracheal, LMA-laryngeal mask airway, PPE-personnel protective equipment, EtCO 2 -end-tidal carbon dioxide, VL-video laryngoscope director-general/speeches/detail/director-general-s-openingremarks-at-the-world-health-assembly COVID-19 and Risks Posed to Personnel During Endotracheal Intubation Difficult airway management in COVID times Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the difficult airway society, the association of anaesthetists the intensive care society, the faculty of intensive care medicine and the Royal college of anaesthetists Indian society of anaesthesiologists (ISA national) advisory and position statement regarding COVID-19 Effectiveness of simulation based teaching of ventilatory management among non-anaesthesiology residents to manage COVID 19 pandemic -A Quasi experimental cross sectional pilot study New COVID-19 clinical guidance website launched for anaesthetists and intensivists. The Royal College of Anaesthetists SASA Covid19 -Covid-19 Updates Physical health risks during simulation-based COVID-19 pandemic readiness training Double gloves: A randomized trial to evaluate a simple strategy to reduce contamination in the operating room Lung function testing in the COVID-19 endemic Airway management for COVID-19: A move towards universal videolaryngoscope? A simple suggestion for safer patient transfer during COVID pandemic A do-it-yourself video laryngoscope for endotracheal intubation of COVID-19 positive patient Protecting healthcare providers from COVID-19 through a large simulation training programme Assessing operating room preparedness for COVID-19 patients through in situ simulations Efficacy of high-fidelity simulation debriefing on the performance of practicing anaesthetists in simulated scenarios Anaesthesia simulation training during coronavirus pandemic: An experience to share A simulation study to evaluate improvements in anesthesia work environment contamination after implementation of an infection prevention bundle Using visualization in simulation for infection control This is a time for facts, not fear,' says WHO chief as COVID-19 virus spreads Maximising application of the aerosol box in protecting healthcare workers during the COVID-19 pandemic Comparison of aerosol box intubation with C-MAC video laryngoscope and direct laryngoscopy-A randomised controlled trial Intubation outcomes using the aerosol box during the COVID-19 pandemic: A prospective, observational study Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic Impact of aerosol box on anxiety of the anaesthesiologist for intubation during COVID-19 pandemic: A single-blinded observational study We would like to acknowledge the help of Mr K. Alben and Mr Edward Jonathan, staff technicians from the Department of Anaesthesia, for the conduct of this study.We would also like to acknowledge Dr Pippa Deodhar for her help in the editing of the manuscript. The study concludes that with the use of a dye to simulate secretions in a low-fidelity mannequin, simulation training can be effectively done with locally available material, to create a safer working environment and improve confidence during the pandemic. How many times did you view the video prior to the baseline simulation?Any other comments: