key: cord-0882917-5scnsgpi authors: Paton, Susan; Clark, Simon; Spencer, Antony; Garratt, Isobel; Dinesh, Ikshitaa; Thompson, Katy-Anne; Bennett, Allan; Pottage, Thomas title: Characterisation of Particle Size and Viability of SARS-CoV-2 Aerosols from a Range of Nebuliser Types Using a Novel Sampling Technique date: 2022-03-19 journal: Viruses DOI: 10.3390/v14030639 sha: ba3749ca2e9d2120721827a155bc4cd1f28a407f doc_id: 882917 cord_uid: 5scnsgpi Little is understood about the impact of nebulisation on the viability of SARS-CoV-2. In this study, a range of nebulisers with differing methods of aerosol generation were evaluated to determine SARS-CoV-2 viability following aerosolization. The aerosol particle size distribution was assessed using an aerosol particle sizer (APS) and SARS-CoV-2 viability was determined after collection into liquid media using All-Glass Impingers (AGI). Viable particles of SARS-CoV-2 were further characterised using the Collison 6-jet nebuliser in conjunction with novel sample techniques in an Andersen size-fractioning sampler to predict lung deposition profiles. Results demonstrate that all the tested nebulisers can generate stable, polydisperse aerosols (Geometric standard deviation (GSD) circa 1.8) in the respirable range (1.2 to 2.2 µm). Viable fractions (VF, units PFU/particle, the virus viability as a function of total particles produced) were circa 5 × 10(−3). VF and spray factors were not significantly affected by relative humidity, within this system where aerosols were in the spray tube an extremely short time. The novel Andersen sample collection methods successfully captured viable virus particles across all sizes; with most particle sizes below 3.3 µm. Particle sizes, in MMAD (Mass Median Aerodynamic Diameters), were calculated from linear regression of log(10)-log(10) transformed cumulative PFU data, and calculated MMADs accorded well with APS measurements and did not differ across collection method types. These data will be vital in informing animal aerosol challenge models, and infection prevention and control policies. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease of 2019 (COVID-19) has been a causative factor in the deaths of more than of 5.6 million people worldwide [1] . There is currently no firm consensus on its routes of transmission, as evidence exists that pathogenic SARS-CoV-2 aerosol particles across a distribution of sizes, play a major role, and that both droplets and aerosols are implicated [2] [3] [4] [5] [6] [7] [8] . "True" aerosol transmission is considered to occur from droplet nuclei, particles < 5 µm, which can remain suspended in the air indefinitely and can penetrate the lower lung [9] . Particles between 5 and 10 µm can travel over shorter distances (metres, depending on surrounding air currents), and be inhaled into the upper respiratory tract; whilst even larger particles from 10 to 100 µm, most likely play a role in either direct transmission [10] , where droplets land directly onto mucosal membranes from the respiratory secretions of another person; or in indirect (fomite) transmission, where they settle onto surfaces subsequently touched, and contamination is transmitted to the mucosal membranes of the face, causing infection [11] . Previous work investigated the survival of The SARS-CoV-2 isolate, England 02/2020 (EPI_ISL_407073) passage 3 (P3) used in this study was propagated by the High Containment Microbiology Department at UKHSA (formerly PHE), Porton Down, Salisbury, UK. The virus was isolated from a clinical sample taken during acute phase illness, using Vero E6 cells (ECACC, 85020206) . A P2 master bank was produced using Vero E6 cells (BEI Resources, NR-596) and a P3 working bank produced in Vero/hSLAM cells (ECACC 04091501). Cell lines were infected at 95% confluence with an of MOI 0.0005-0.01 and maintained in 1× Minimal Essential Medium GlutaMax (Gibco, Grand Island, New York, USA), 4% heat-treated foetal bovine serum(Sigma, St Louis, MO, USA), 1× non-essential amino acids (Gibco, Paisley, Scotland, UK), 25 mM HEPES buffer (Gibco, Paisley, Scotland, UK); additionally, Vero/hSLAM cells were also maintained in the presence of 0.4 mg/mL geneticin (Gibco, Grand Island, New York, USA ). Virus was harvested 3 to 6 days post-infection and supernatant clarified by centrifugation (3000 rpm, 10 min). Virus was aliquoted and stored at −80 • C. The titre of the P3 virus stock was determined to be 2.0 × 10 7 PFU (plaque forming units)/mL by plaque assay. All work handling SARS-CoV-2 was performed within a containment level 3 laboratory. Six different nebulisers, with four types of nebulising action, were selected to aerosolise SARS-CoV-2 under different relative humidities (RH). The nebulisers are listed in Table 1 . in an order relevant to the degree of physical impact of the aerosolization process on the pathogen (shear forces generated from pressure, from highest to lowest): SLAG operation: To avoid damaging the perforated disc elements, the pressure was gradually increased by increasing the air flow applied in increments for each run. Similarly, the volume of virus inoculum applied during operation was altered to produce visible, vigorous bursting bubbles without excessive foaming, by increasing and decreasing the speed of the peristaltic pump used to aliquot the liquid. It was found, especially for the 90 mm SLAG, that pre-wetting the perforated 90 mm disc moments before applying compressed air to the system, achieved maximal levels of bubble bursting (sparging). Due to limitations on time, the air pressure and inoculum volume were not fully optimised for the 1 inch SLAG, however the ranges applied to both disc sizes appear in Table 1 . All other nebulisers were used according to the manufacturer's instructions. A Henderson apparatus allows closed-circuit containment and direction of microbial aerosols generated from a nebuliser at a controlled relative humidity ( Figure 1 ). The Henderson apparatus was used to deliver aerosols of SARS-CoV-2 at 40 L/min (balancing the total flow between the nebuliser and the Biaera unit) and the aerosols were collected at the end of the apparatus spray tube using biological samplers. The apparatus was contained within a flexible film isolator (FFI) within Containment Level 3 facilities. The challenge system is controlled by an AeroMP control unit (Biaera, Hagerstown, MD, USA). The AeroMP is a platform system designed to manage the aerosol generation, characterisation and sampling processes via a dashboard software laptop system. The aerosol management platform controls, monitors, and records all relevant parameters during an aerosol procedure including air flow rates, generated pressures, temperature and relative humidity. The software automatically monitors the conditions in the apparatus and balances the system airflows. The mean temperature during all experiments was 23.4 • C, range 21 • C to 25 • C. Viruses 2022, 14, x FOR PEER REVIEW 4 of 13 total flow between the nebuliser and the Biaera unit) and the aerosols were collected at the end of the apparatus spray tube using biological samplers. The apparatus was contained within a flexible film isolator (FFI) within Containment Level 3 facilities. The challenge system is controlled by an AeroMP control unit (Biaera, Hagerstown, MD, USA). The AeroMP is a platform system designed to manage the aerosol generation, characterisation and sampling processes via a dashboard software laptop system. The aerosol management platform controls, monitors, and records all relevant parameters during an aerosol procedure including air flow rates, generated pressures, temperature and relative humidity. The software automatically monitors the conditions in the apparatus and balances the system airflows. The mean temperature during all experiments was 23.4 °C, range 21 °C to 25 °C. An APS device (model 3321, TSI Inc., Shoreview, MN, USA) was used to determine the size distributions of particles in aerosolised viruses, nebulised, and routed through the Henderson Apparatus. The APS device was set to sample 1:100 dilution, for two 30 s periods at 30 s and 4 min post-initiation of nebulisation. The sample was taken at the end of the spray tube and in an equivalent location to where animals would theoretically be exposed to the aerosol. See Figure 1 . To assess viability of nebulised viruses, all-glass impingers (AGI-30) containing 10 mls of cMEM (complete Minimal Essential Medium [12] ) and operating at 12 L/min were connected to the Henderson apparatus down-stream of the spray tube (see Figure 1 ) for the duration of 5-min sprays [34] . A 6-stage Andersen sampler was used to fractionate the aerosols generated by the 6jet Collison nebuliser into different sizes during sampling [35] . Relative humidity was maintained within a range of 45 to 60%. The Andersen was operated for 5 min at 28.3 L/min and was placed at the same point as the AGI-30 in the previous experiments, see Figure 1 . Three different collection methods were employed in the Andersen's stages (differing from the normal solid agar media used) to ensure the viral particles could be captured and enumerated, using glass petri dishes to reduce the effects of static charge: (a) 27 mL of cMEM (stages 1-5 only); (b) 20 mL 2% agarose plus 7 mL cMEM (6 stages); or (c) An APS device (model 3321, TSI Inc., Shoreview, MN, USA) was used to determine the size distributions of particles in aerosolised viruses, nebulised, and routed through the Henderson Apparatus. The APS device was set to sample 1:100 dilution, for two 30 s periods at 30 s and 4 min post-initiation of nebulisation. The sample was taken at the end of the spray tube and in an equivalent location to where animals would theoretically be exposed to the aerosol. See Figure 1 . To assess viability of nebulised viruses, all-glass impingers (AGI-30) containing 10 mls of cMEM (complete Minimal Essential Medium [12] ) and operating at 12 L/min were connected to the Henderson apparatus down-stream of the spray tube (see Figure 1 ) for the duration of 5-min sprays [34] . A 6-stage Andersen sampler was used to fractionate the aerosols generated by the 6-jet Collison nebuliser into different sizes during sampling [35] . Relative humidity was maintained within a range of 45 to 60%. The Andersen was operated for 5 min at 28.3 L/min and was placed at the same point as the AGI-30 in the previous experiments, see Figure 1 . Three different collection methods were employed in the Andersen's stages (differing from the normal solid agar media used) to ensure the viral particles could be captured and enumerated, using glass petri dishes to reduce the effects of static charge: (a) 27 mL of cMEM (stages 1-5 only); (b) 20 mL 2% agarose plus 7 mL cMEM (6 stages); or (c) Gelatine Membranes (6 stages), 0.2 µm pore size (Sartorius, Goettingen, Germany). Four sterilised glass microscope slides were stacked under each gelatine membrane, to raise them to the correct height for size-based impaction to occur. Post-exposure, gelatine membranes were dissolved in 10 mL warmed cMEM for 1 min with agitation, before collecting for assay. All biological sampling liquids described above were transferred to a cryotube for storage at −80 • C before analysis. The process of storing samples at −80 • C then thawing before processing was not found to significantly affect viability of the virus [12] . Plaque assays were completed according to protocols described previously [12] . Briefly, the thawed collection fluid was serially diluted 1 in 10 to an appropriate dilution, then plaque assayed on Vero-E6 cells, before staining and enumeration of plaques. The number of plaques in each well was determined and expressed as PFU. Virus titre in samples collected from nebulisers, AGI and Andersen samplers was calculated by taking averages of technical replicates (plaque assay performed in duplicate), to give PFU/mL; this was then multiplied by the total liquid volume of the sample to give total PFU. Viable fraction (VF) values were calculated for each nebuliser assessed. The VF is the relationship of viable virus particles arising from the total number of particles nebulised. It is found from the total PFU collected in the AGI, divided by the total number of particles counted by the APS during the 5-min spray. The units are PFU/particle. Spray Factors (SF) were calculated for each nebuliser assessed. The SF is a unitless ratio that defines a relationship between the viability of a challenge suspension in the nebulizer (C neb , PFU/L) and the concentration of viable virus in the circulating aerosol (C aero , PFU/L) and is commonly used in animal aerosol challenge models [23, 29, 36] . The value obtained is system dependent, but it allows comparisons of stability between different agents used: The concentration of virus in the circulating aerosol (C aero ) is calculated by the formula: where C imp is the concentration of virus (PFU/L), V imp is the volume of collection fluid in the AGI (mL), Q imp is the sample flow rate of the AGI (L/min), and t exp is the exposure time (min). Virus concentrations in C aero are converted to PFU/L to allow calculation against C neb in PFU per litre of air sampled. Calculation of Mass Median Aerodynamic Diameter (MMAD) size from Andersen data: Total PFU was used to calculate (in Microsoft Excel) cumulative percentage collected at each stage 1 to 6 as: These percentages were plotted against the size cut-off for each stage, here the cut-offs for stages 1 to 6 are 7 µm, 4.7 µm, 3.3 µm, 2.1 µm, 1.1 µm, and 0.65 µm, respectively; and log 10 transformed on both axes. A linear regression line was added and the particle size at 50% is then taken as the MMAD for that run. This took place in GraphPad Prism v9. All nebulisers produced particles in the respirable size range, as measured by the APS, Table 2 . MMAD values tended to be smaller for each nebuliser at the lower RH range, but this was not statistically significant (p > 0.05). Across all RH values, aerosol particles with the lowest MMAD were produced from the PARI Sprint Star, compared to the Omron (p = 0.0012) and the 1 inch SLAG (p = 0.0132); no other MMAD results were significant. The PARI SprintStar also had the lowest level of variance in the size distribution, calculated by geometric standard deviations (GSD) (ca. 1.6); indicating production of mono-disperse aerosols of ca. 1.2 µm diameter from this nebuliser. The nebuliser which produced the widest distribution of particle sizes was the 1 inch SLAG (GSD of ca. 2); indicating high polydispersity. This was only significant compared to the GSDs of the Omron (p = 0.0018) and Sprint Star (p = 0.0134). Table 2 . APS data for nebulised SARS-CoV-2 at varying relative humidities. MMAD, mass median aerodynamic diameter; GSD, geometric standard deviation, is a unitless number that denotes size distribution of the aerosols produced. GSD figures are presented as the range of values calculated by the APS for repeat runs. Runs were performed three times unless stated; * denotes n = 1,ˆdenotes n = 2, $ denotes n = 5. ND = not done. Viable virus was consistently recoverable from the AGI and from all six nebuliser reservoirs following aerosolization for 5 min, across three different relative humidity ranges. Figure 2 shows that median VF values across all RH values were between 6.7 × 10 −6 (Collison 6 jet) to 2.6 × 10 −2 (90 mm SLAG). Overall, the SLAG nebulisers resulted in higher VF values (suggestive of their gentler mode of action on aerosol generation), compared to the four other nebuliser types, though only the 90 mm SLAG results were significantly higher than the 3-jet and 6-jet Collisons (p = 0.010). Humidity did not significantly impact VF values (p = 0.177), but values were slightly less variable at lower RH, with coefficients of variation for high, intermediate, and low RH of 206.3%, 235.2%, and 125.5%, respectively. Spray factor values were also calculated across all RH values; the PARI Sprint Star produced the highest SF, with the 3-and 6-jet Collisons and the Omron within 1 log 10 of this; SF for the SLAGs were the lowest of all. For each nebuliser the median and standard error are given below (in descending order): PARI SprintStar 2.77 × 10 −6 (1.83 × 10 −5 ); Collison 6-jet 2.23 × 10 −6 (1.97 × 10 −6 ); Collison 3-jet 1.85 × 10 −6 (8.70 × 10 −7 ); Omron MicroAIR U22 1.66 × 10 −6 (1.20 × 10 −6 ); 90 mm SLAG 6.45 × 10 −7 (4.31 × 10 −7 ); 1 inch SLAG 3.19 × 10 −8 (7.5 × 10 −8 ). The SF generated from the PARI SprintStar was significantly higher than that from the 1 inch SLAG, (p = 0.012); but no other SF's differed between nebulisers. Humidity did not significantly impact SF values (p = 0.609). Spray factor values were also calculated across all RH values; the PARI Sprint Star produced the highest SF, with the 3-and 6-jet Collisons and the Omron within 1 log10 of this; SF for the SLAGs were the lowest of all. For each nebuliser the median and standard error are given below (in descending order): PARI SprintStar 2.77 × 10 −6 (1.83 × 10 −5 ); Collison 6-jet 2.23 × 10 −6 (1.97 × 10 −6 ); Collison 3-jet 1.85 × 10 −6 (8.70 × 10 −7 ); Omron MicroAIR U22 1.66 × 10 −6 (1.20 × 10 −6 ); 90 mm SLAG 6.45 × 10 −7 (4.31 × 10 −7 ); 1inch SLAG 3.19 × 10 −8 (7.5 × 10 −8 ). The SF generated from the PARI SprintStar was significantly higher than that from the 1inch SLAG, (p = 0.012); but no other SF's differed between nebulisers. Humidity did not significantly impact SF values (p = 0.609). The novel virus collection methods employed on the Andersen sampler were comparable to each other in overall efficiency, and particle size fractionation capability, when SARS-CoV-2 was aerosolised from a Collison 6-jet nebuliser. Figure 3 shows the comparison in biological sampling efficiency for the three sampling methods employed. For all three, the majority of SARS-CoV-2 particles were collected on the lower stages of the sampler, <3.3 µm. The liquids in the AGI samplers, collected from the Collison 6-jet (first study), contained 4.48 × 10 3 pfu/L, (standard deviation 2.39 × 10 3 ), which is comparable to the PFU/L collected by the Andersen methods: total PFU recovered across all stages, per litre of air sampled (with standard deviations) were: 27mL cMEM, 3.8 × 10 3 pfu/L (sd 2.7 × 10 3 ); 7 mL cMEM, 7.1 × 10 2 pfu/L (sd 6.9 × 10 2 ); and Gelatine, 2.0 × 10 2 pfu/L (sd 1.4 × 10 2 ). The total PFU/L across the three Andersen methods and AGI sampler were not significantly different (p = 0.241). Viable fraction (VF) values for nebulisers at different relative humidity ranges. Each data point represents one biological repeat: magenta circles > 60% RH; teal triangles 45 to 60% RH; purple squares < 45% RH; black line is the median value across all RH's for that nebuliser. The novel virus collection methods employed on the Andersen sampler were comparable to each other in overall efficiency, and particle size fractionation capability, when SARS-CoV-2 was aerosolised from a Collison 6-jet nebuliser. Figure 3 shows the comparison in biological sampling efficiency for the three sampling methods employed. For all three, the majority of SARS-CoV-2 particles were collected on the lower stages of the sampler, <3.3 µm. The liquids in the AGI samplers, collected from the Collison 6-jet (first study), contained 4.48 × 10 3 pfu/L, (standard deviation 2.39 × 10 3 ), which is comparable to the PFU/L collected by the Andersen methods: total PFU recovered across all stages, per litre of air sampled (with standard deviations) were: 27mL cMEM, 3.8 × 10 3 pfu/L (s.d. 2.7 × 10 3 ); 7 mL cMEM, 7.1 × 10 2 pfu/L (s.d. 6.9 × 10 2 ); and Gelatine, 2.0 × 10 2 pfu/L (s.d. 1.4 × 10 2 ). The total PFU/L across the three Andersen methods and AGI sampler were not significantly different (p = 0.241). The PFU collected across each stage allowed the calculation of MMAD for each media type. These numbers correspond well to the MMADs as measured by the APS ( Table 3 ). The GSD, as measured by the APS, denotes polydispersity of particles around 1.7 µm, from the 6-jet Collison, which corresponds to the earlier measurements at different RH ranges ( Table 3 ). The collection methods are not statistically different from each other, in terms of MMAD. The PFU collected across each stage allowed the calculation of MMAD for each media type. These numbers correspond well to the MMADs as measured by the APS (Table 3 ). The GSD, as measured by the APS, denotes polydispersity of particles around 1.7 µm, from the 6-jet Collison, which corresponds to the earlier measurements at different RH ranges ( Table 3 ). The collection methods are not statistically different from each other, in terms of MMAD. Table 3 . Particle sizes and size distributions of particles collected via three sampling methods in the Andersen, using both calculated and APS-measured values. Two values for MMADs (mass median aerodynamic diameters) were found by: (Left-hand side, MMAD (calc)); calculation from the cumulative percentage deposition of viable viral particles across the stages, and (Right-hand side), as measured by the APS. GSD average is found from the median values, as measured from the APS, and is a unitless number. Table 3 . Particle sizes and size distributions of particles collected via three sampling methods in the Andersen, using both calculated and APS-measured values. Two values for MMADs (mass median aerodynamic diameters) were found by: (Left-hand side, MMAD (calc)); calculation from the cumulative percentage deposition of viable viral particles across the stages, and (Right-hand side), as measured by the APS. GSD average is found from the median values, as measured from the APS, and is a unitless number. This study demonstrates that both established and novel nebulisers can be used to generate stable and viable SARS-CoV-2 aerosols. The 90 mm SLAG generated aerosols with the highest viability fraction; demonstrating a gentle nebulisation action. Aerosols generated at lower RH produced fewer variable data, but overall RH did not significantly influence the viability, size or numbers of viable particles produced. The Hendersen apparatus, where generated aerosols pass from the nebuliser to the point of delivery (AGI or animal challenge equipment) within 40 microseconds, is designed to ensure even mixing of the aerosol, rather than its conditioning. In order to observe any effects of humidity on Viruses 2022, 14, 639 9 of 12 aerosols, a system such as the Goldberg drum should be employed. In terms of particle sizing and size distributions, the PARI Sprint Star produced the particles of smallest MMAD and GSD, and was the producer of the highest number of viable particles overall. To this author's knowledge, no work characterising microbial aerosols from the PARI Sprint Star has been produced, thus representing an exciting avenue for future research in experimental microbial aerosol generation. In others' work characterising nebulisers (including a Collison nebuliser and the Omron MicroAir U22), in creation of airborne virus aerosols, Niazi et al. [37] found that the Collison reduced viability of generated influenza aerosols more than the other nebulisers studied. However, the nebulisation time was six times longer than this study, and the recirculating nature of the Collison means it is less suited to such long spray times. However, the GSDs measured from the Collison and Omron nebulisers in that work accord well with ours, suggesting a similar particle size distribution, even between different virus types. Others, working with the SLAG to generate viral aerosols have had less success; Fennelly et al. failed to detect either viral RNA nor viable flu particles from SLAG nebulisation [38] . The SLAG systems, in this author's opinion, represent an interesting avenue for further research for fragile microbial aerosols, especially as this study demonstrated the potential in further optimisation of the SLAG 1 inch. Further APS data produced during this study included the CMAD value (count median aerodynamic diameter), a size calculation based on the number distribution of an aerosol. Due to the large numbers of very small particles (less than 1 µm in diameter) produced by nebulisers, CMAD will give smaller size calculations compared to MMAD. However, CMAD is less used in the study of microbial aerosols, as, the smaller a particle is, the less likely it is to contain a virion/bacterium. Traditionally, cascade samplers are employed to measure the size distribution of the viable particles in microbial aerosols, through calculation of MMAD as described. Thus, our Andersen data and APS MMAD data are the most relevant in describing particle size distributions in this study. This study was designed to determine the effectiveness of the nebulisers' interactions with SARS-CoV-2, to understand and inform the design of effective animal models utilising an aerosol infection route. Determination of spray factor allows one to calculate the presented dose to an animal, based on any given concentration of a pathogen in a nebuliser and is specific both to the aerosol challenge system (apparatus, mode of aerosolization, etc.) and the individual organism. For example, another respiratory pathogen, Influenza H1N1, delivered via a 6-jet Collison in the same Biaera/Hendersen system as used here has a SF of 1.32 × 10 −6 [39, 40] which is comparable to our derived value for SARS-CoV-2 of 2.23 × 10 −6 in the same system. Our study also showed that the SLAG, mesh and jet nebulisers were no more likely to inactivate SARS-CoV-2 than either of the more standard Collison nebulisers, within our system. The lack of significant influence of RH, or even nebuliser type (excluding the 1-inch SLAG) on spray factors, demonstrates that the practice of using Collison nebulisers is predicted to not have a negative impact on the viability of particles generated in a SARS-CoV-2 infection model. Specific spray factor values calculated in this study will be used to determine the starting inoculum in an aerosol challenge system, required to give a specific presented dose (or range of doses) to animals. These data will allow improved and reproducible infection and interpretation of disease development and assessment of interventions in this model. This study also demonstrated three novel aerosol collection methods for use within an Andersen sampler, which, overall, had comparable collection efficiencies compared to the AGI sampler for SARS-CoV-2. This corroborates the work of others such as Kutter et al. [41] , Fennelly et al. [42] and Kulkarni et al. [43] who also successfully collected respiratory viruses within an Andersen sampler used with viral collection methods such as agar, semisolid gelatine, or liquid media. Our collection rates (in terms of PFU collected per litre of air sampled) were higher than those aforementioned studies, but small differences such as our use of glass petri dishes over plastic ones (known to influence efficiency due to static forces generated by air flows [35] ), may have contributed to this difference. This study was not designed to provide an in-depth functional analysis of different nebuliser types. Many others, employing tracers to characterise the physical efficiencies of nebulisers, have performed this thoroughly [24] [25] [26] [27] [28] 44, 45] . However, to this author's knowledge, the efficacy of different nebuliser types has yet to be explored for SARS-CoV-2 [46] . Similarly, most animal studies exploring SARS-CoV-2 have challenged animals intra-nasally, intra-ocularly, or intra-orally, with few delivered by the aerosol route [14] [15] [16] [17] [18] . Only one recent study examined natural transmission between intra-nasally infected hamsters to naïve animals [47] . Our study sought to characterise the MMAD and viability of SARS-CoV-2 aerosols generated with different relative humidities from six nebulisers. To date, no other work has compared nebulisation effects on SARS-CoV-2 across such devices; nor attempted to characterise by size-fractionation, viable SARS-CoV-2 virus particles, using these methods. The authors acknowledge the limitations of this study, which were largely influenced by access to key containment facilities during the COVID-19 pandemic. This resulted in a lack of time to optimise the parameters for the relatively novel SLAG nebulisers. These have not been often used in virus aerosolization studies, by this group or others, and reflects the investment needed to establish the most effective parameters. Facility access also limited the numbers of runs that could be completed across the ranges of RH explored. We acknowledge that the use of the large fill volume within the Andersen, and the need to exclude the lowest Anderson stage to prevent media overspill, makes it unwieldy and impractical for field studies. As recovery of viable virus from the 7 mL fill volume of the Andersen sampler compared to the AGI was only 0.81 log 10 less, and particle size characterisation was accurate compared to the APS, we would recommend the 7 mL + agarose base collection method for use either in in vitro lab studies, or in the indoor built environment. Future studies replicating this work will determine if any differences in viability or particle sizes arise between variant strains; which may help inform policy and provide important information for future aerosol studies in animals. Future work employing different aerosol capture methods, such as the Goldberg drum or spider microthreads, could explore decay rates over longer time periods, of virus in different temperature and relative humidities, and also incorporate electron microscopy images of the virus to determine physical effects of nebulisation compared to those observed in sputum. Future work may also involve comparison of natural transmission in animal models [47] to those animals infected via nebuliser-generated aerosols; such work may aid elucidation of the particle sizes and concentrations generated by intra-nasally infected animals, in aerosol infection models. Detection of viable viruses such as SARS-CoV-2 in air remains difficult, due to their usually low concentration and the negative impacts on viability that air sampling forces have on fragile enveloped viruses. This work establishes a new method of detecting and fractionating such particles; and demonstrates that SARS-CoV-2 generated by nebulisers have the potential to transmit to the deep lung; highly relevant to in vivo models. These data will also inform further in vitro aerosol studies and set the foundation for in vivo studies designed to understand transmission and disease caused by the aerosol route of infection with SARS-CoV-2, and may aid in informing infection prevention and control policies for indoor air. Aerosol Transmission of SARS-CoV-2? Evidence, Prevention and Control Transmission of COVID-19 Virus by Droplets and Aerosols: A Critical Review on the Unresolved Dichotomy Airborne Transmission of SARS-CoV-2: Theoretical Considerations and Available Evidence It Is Time to Address Airborne Transmission of Coronavirus Disease 2019 (COVID-19) Airborne Spread of SARS-CoV-2 and a Potential Role for Air Disinfection A Mathematical Framework for Estimating Risk of Airborne Transmission of COVID-19 with Application to Face Mask Use and Social Distancing Droplets and Aerosols: An Artificial Dichotomy in Respiratory Virus Transmission Impact of Inhalation Exposure Modality and Particle Size on the Respiratory Deposition of Ricin in BALB/c Mice Airborne Transmission of SARS-CoV-2 Recognition of Aerosol Transmission of Infectious Agents: A Commentary Persistence of SARS-CoV-2 Virus and Viral RNA in Relation to Surface Type and Contamination Concentration A Comparison of Persistence of SARS-CoV-2 Variants on Stainless Steel Simulation of the Clinical and Pathological Manifestations of Coronavirus Disease SARS-CoV-2 Infection Protects against Rechallenge in Rhesus Macaques Primary Exposure to SARS-CoV-2 Protects against Reinfection in Rhesus Macaques Respiratory Disease in Rhesus Macaques Inoculated with SARS-CoV-2 DNA Vaccine Protection against SARS-CoV-2 in Rhesus Macaques SARS-CoV-2 Disease Severity and Transmission Efficiency Is Increased for Airborne Compared to Fomite Exposure in Syrian Hamsters Defining the Syrian Hamster as a Highly Susceptible Preclinical Model for SARS-CoV-2 Infection Particle Size and Pathogenicity in the Respiratory Tract Ferrets Develop Fatal Influenza after Inhaling Small Particle Aerosols of Highly Pathogenic Avian Influenza Virus A/Vietnam/1203/2004 (H5N1) The Automated Bioaerosol Exposure System: Preclinical Platform Development and a Respiratory Dosimetry Application with Nonhuman Primates Design and Performance of a Single-Pass Bubbling Bioaerosol Generator In Vitro Aerodynamic Characterization of the Dose Emitted during Nebulization of Tobramycin High Strength Solution by Novel and Jet Nebulizer Delivery Systems Omron NE U22: Comparison Between Vibrating Mesh and Jet Nebulizer Comparison of the Performance of Inhalation Nebulizer Solution and Suspension Delivered with Active and Passive Vibrating-Mesh Device The Collison Nebulizer Description, Performance and Application The Omron MicroAir Vibrating Mesh Technology Nebuliser, a 21st Century Approach to Inhalation Therapy Aerosols and Aerosol Drug Delivery Systems A Systematic Comparison of Four Bioaerosol Generators: Affect on Culturability and Cell Membrane Integrity When Aerosolizing Escherichia coli Bacteria A Mobile Form of the Henderson Apparatus New Sampler for the Collection, Sizing and Enumeration of Viable Airborne Particles Survival of Mycobacterium Tuberculosis during Experimental Aerosolization and Implications for Aerosol Challenge Models Characterization of the Utility of Three Nebulizers in Investigating Infectivity of Airborne Viruses Collection and Measurement of Aerosols of Viable Influenza Virus in Liquid Media in an Andersen Cascade Impactor Influenza A Virus Challenge Models in Cynomolgus Macaques Using the Authentic Inhaled Aerosol and Intra-Nasal Routes of Infection PHE Efficacy of Medi-Immune Inhaled Air Sterilisation Device in the Influenza Challenge Model Comparison of Three Air Samplers for the Collection of Four Nebulized Respiratory Viruses-Collection of Respiratory Viruses from Air Particle Sizes of Infectious Aerosols: Implications for Infection Control Evidence of Respiratory Syncytial Virus Spread by Aerosol. Time to Revisit Infection Control Strategies? Comparison of Plasma and Pulmonary Availability of Chlorogenic Acid, Forsythiaside A and Baicalin after Intratracheal and Intravenous Administration of Shuang-Huang-Lian Injection Working Mechanism and Behavior of Collison Nebulizer Effects of Humidity and Other Factors on the Generation and Sampling of a Coronavirus Aerosol Development of a Hamster Natural Transmission Model of Sars-Cov-2 Infection The authors would like to express sincere thanks to the staff of the Biological Services and the TB Research group, who provided access to and assistance in, the CL3 facilities used. The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.