key: cord-0879075-ufd7llza authors: Scheier, Thomas; Shah, Cyril; Huber, Michael; Sax, Hugo; Hasse, Barbara; Günthard, Huldrych F.; Trkola, Alexandra; Schreiber, Peter W. title: Do we cause false positives? An experimental series on droplet or airborne SARS-CoV-2 contamination of sampling tubes during swab collection in a test center date: 2021-03-09 journal: Antimicrob Resist Infect Control DOI: 10.1186/s13756-021-00920-z sha: 2d6e7dc5b9dac8a8d8c791e5e146bc98ec43d400 doc_id: 879075 cord_uid: ufd7llza The rapid spread of the coronavirus disease 2019 pandemic urged immense testing capacities as one cornerstone of infection control. Many institutions opened outpatient SARS-CoV-2 test centers to allow large number of tests in comparatively short time frames. With increasing positive test rates, concerns for a possible airborne or droplet contamination of specimens leading to false-positive results were raised. In our experimental series performed in a dedicated SARS-CoV-2 test center, 40 open collection tubes placed for defined time periods in proximity to individuals were found to be SARS-CoV-2 negative. These findings argue against false-positive SARS-CoV-2 results due to droplet or airborne contamination. In December 2019, a novel Coronavirus, later named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), was detected as causative pathogen in a cluster of pneumonia of unknown cause in Wuhan, China [1] . Since then, multiple assays for the detection of SARS-CoV-2 were established, enabling diagnosis of coronavirus disease 2019 (COVID-19). Besides nucleic acid amplification tests, antigen-based tests and serological assays are now available [2, 3] . An increasing demand for test capacities due to the pandemic spread prompted implementation of outpatient SARS-CoV-2 test centers. Considering the high sensitivity of SARS-CoV-2 polymerase chain reaction (PCR) used in highly frequented test center settings, concerns of false-positive PCR results due to contamination during pre-analytic processes occurred. The objective of the present study was to investigate, whether sampling tubes can be inadvertently contaminated with SARS-CoV-2 by droplets or aerosols generated by SARS-CoV-2 infected individuals during nasopharyngeal swab (NPS) sampling. This study was performed at the SARS-CoV-2 test center of the University Hospital Zurich (USZ), Zurich, Switzerland. The center serves as referral center for all outpatient clinics of the USZ and is open for public. All individuals attending the SARS-CoV-2 test center are obliged to wear nose-mouth masks and to perform an alcohol-based hand disinfection at entry. Healthcare worker (HCW) register the personal data and assess symptoms compatible with COVID-19 using a standardized questionnaire Open Access *Correspondence: thomas.scheier@usz.ch 1 Division of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich and University of Zurich, Zurich, Switzerland Full list of author information is available at the end of the article before testing. A physical examination is not performed. During the swab procedure the nose-mouth mask is temporarily removed. After gathering the nasopharyngeal swab, individuals leave the test center directly and the results are provided by a phone call or short message service. In normal operation, the room is throughout ventilated by a tilted window. Between consecutive tests, the exterior doors are opened and all surfaces that were in contact with the tested individual are disinfected. Health care workers performing the swab procedure are wearing gloves, gowns, surgical masks (type 2R) and googles. Gloves are either changed or disinfected (for a maximum of five times) after every patient. Gowns are changed at the end of the shift, or if the assigned rooms for swab collection are left. The experimental series was performed in two adjacent rooms designated for individuals with COVID-19 compatible symptoms or a history of relevant SARS-CoV-2 exposure (Fig. 1 ). Both rooms featured a similar room size (room A 18.96 m 2 and room B 19.88 m 2 ) and window area (room A and B around 1.7 m 2 ). Both rooms have horizontal pivot windows. Individuals that presented for SARS-CoV-2 testing were seated in front of the window for NPS collection. In room A, the window was permanently tilted for continuous air exchange. In room B, the window was closed during the experimental runs, each lasting 60 min. Then, the window was tilted for about 10 min before launching the next experimental run. Both rooms featured no ventilation systems. In each room, three open tubes (15 ml, opening diameter 17 mm) filled with 3 ml viral transport medium (VTM) were placed at a distance of 50cm and 100cm to the patient. At each distance, one tube was sealed after 5, 10 and 60 min, respectively. This procedure was repeated for a total of three times. In addition, at both distances one separate open tube filled with 3 ml VTM was placed at the beginning of the first experimental series and was closed at the end of the third experimental series. To avoid contact transmission, HCW performed a hygienic hand disinfection routinely prior to handling of virus sample tubes. The overall number of persons that received SARS-CoV-2 testing in these rooms during the experimental series was registered. Results of the SARS-CoV-2 tests and the corresponding cycle thresholds (cT) values were retrieved from the electronic patient information system. All samples were analyzed at the Institute of Medical Virology of the University of Zurich. SARS-CoV-2 PCR analyses were performed with Roche Cobas SARS-CoV-2 IVD test (Roche Diagnostics, Mannheim, Germany) and an in-house high input PCR. Briefly, 100 µl of sample were lysed with 50 µl AVL buffer (Qiagen, Venlo, the Netherlands), precipitated with 150 µl EtOH and centrifuged at 21,000g for 1 min. The supernatant was removed, and the pellet resuspended with 35 µl of water. RT-qPCR was performed targeting the E-and the N-gene according to Corman et al. [4] with 16 µl eluate each using the TaqMan Fast Virus 1-Step Master Mix (Thermo Fisher, Waltham, MA, USA). At the day of the experiments, totally 254 persons presented at the SARS-CoV-2 test center. Among these, 47 individuals tested positive, corresponding to a positivity rate of 18.5%. During the experimental series, 39 persons were tested for SARS-CoV-2 in room A and 41 persons in room B, respectively. In both rooms, the number of persons that received NPS sampling was similar for all predefined sampling periods (detailed information is provided in Table 1 The present study addressed the question whether false-positive results for SARS-CoV-2 could result from droplet or airborne contamination originating from individuals that have been sampled previously in the same room. Our experimental series encompassed various exposure times, two different settings regarding ventilation and two PCR assays, including a commonly used assay for SARS-CoV-2 diagnostics and a highly sensitive high input PCR, did not detect any contamination of open sampling tubes with SARS-CoV-2. Prior studies reported contamination of several surfaces with SARS-CoV-2 next to infectious individuals [5] . Surroundings of infected individuals can either get contaminated by SARS-CoV-2 containing droplets, which is considered as by far the most relevant transmission mode, or exhaled aerosols or via contact transmission, e.g. if devices are touched after hands have been contaminated during coughing. The estimated median halflife of viable SARS-CoV-2 on different materials in an experimental setting was about 6.8 h and 5.6 h on plastics and stainless steel, respectively [6] . The high proportion of COVID-19 affected individuals in dedicated test centers promotes environmental contamination with SARS-CoV-2, and the level of contamination presumably increases with proximity to infected persons. As detailed above, the main transmission mode of SARS-CoV-2 occurs via droplets expelled during talking, coughing or sneezing [3] . For smaller droplets or aerosols, which can be generated during coughing by some individuals, ventilation becomes relevant for clearance [3, 7] . Our experimental set-up included a room without any enhanced air exchange and a room with continuous air exchange via tilted windows. Independent of the set-up all samples tested negative, even in a high input PCR with increased sensitivity. Our study has some limitations. We can only provide information on the number of individuals that tested SARS-CoV-2 positive during the experimental series in both rooms. We did not register which patients were assigned to either room A or B. Nevertheless, as all samples tested negative, the assignment to the individual room does not seem crucial for the interpretation of the results. In addition, we did not swab surfaces to test for environmental contamination. However, considering the strict application of personal protective equipment, hand hygiene and surface disinfection, contamination around infected individuals is likely very limited. Strict application of hand hygiene and glove change of HCWs were likely crucial to prevent contamination of virus sample tubes. In conclusion, we could not detect SARS-CoV-2 contamination of open collection tubes during NPS collection, even if these specimens remained unsealed for more than 3 h. Stringent use of personal protective equipment, including wearing of a surgical mask by the individual to be tested as a component of source control, hand hygiene and regular surface disinfection prevented successfully contamination. Furthermore, adequate specimen handling includes immediate closure after insertion of the NPS, thus minimizing the risk of contamination. Rolling updates on coronavirus disease (COVID-19) World Health Organization. Diagnostic testing for SARS-CoV-2 Pathophysiology, transmission, diagnosis, and treatment of coronavirus disease 2019 (COVID-19): a review Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Small droplet aerosols in poorly ventilated spaces and SARS-CoV-2 transmission Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We warmly thank Gülen Akdemir for realizing the experiments and Rebecca Morrone, Martin Ringer and all other health care workers from the test center for their commitment. TS and PWS designed the experimental set up and drafted the initial manuscript. CS, MH and AT performed the virological analyses. HFG and BH helped in the experimental set up. All authors read, critically revised and approved the final manuscript. Ready to submit your research Ready to submit your research ? Choose BMC and benefit from:? Choose BMC and benefit from:Funding PWS is supported by the academic career program "Filling the Gap" of the Medical Faculty of the University of Zurich. The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request. Ethics approval and consent to participate As exclusively aggregated and anonymized SARS-CoV-2 results from individuals presenting at the test center were reported and solely environmental samples were gathered for analyses, a formal ethical evaluation was not needed. Not applicable.