key: cord-0878787-y4jpsoem authors: Ko, Dayoung; Lyons, Alexis B.; Kohli, Indermeet; Narla, Shanthi; Torres, Angeli Eloise; Miller, Angela; Ozog, David; Hamzavi, Iltefat; Lim, Henry W. title: The value of photomedicine in a global health crisis: Utilizing ultraviolet C to decontaminate N95 respirators during the COVID‐19 pandemic date: 2021-09-09 journal: Photodermatol Photoimmunol Photomed DOI: 10.1111/phpp.12729 sha: ef5f4e5ba664f36a52f76e4314c14acbb6ecab30 doc_id: 878787 cord_uid: y4jpsoem One early problem during the height of the COVID‐19 global pandemic, caused by severe acute respiratory syndrome 2 (SARS‐CoV‐2), was the shortage of personal protective equipment donned by healthcare workers, particularly N95 respirators. Given the known virucidal, bactericidal, and fungicidal properties of ultraviolet irradiation, in particular ultraviolet C (UVC) radiation, our photomedicine and photobiology unit explored the role of ultraviolet germicidal irradiation (UVGI) using UVC in effectively decontaminating N95 respirators. The review highlights the important role of photobiology and photomedicine in this pandemic. Namely, the goals of this review were to highlight: UVGI as a method of respirator disinfection—specifically against SARS‐CoV‐2, adverse reactions to UVC and precautions to protect against exposure, other methods of decontamination of respirators, and the importance of respirator fit testing. utilizes the germicidal properties of UVC and is produced from a lowpressure mercury or light-emitting diode (LED) lamp source, which emits a peak wavelength of 254 nm. This peak wavelength is near the maximum absorption of nucleic acids at 265 nm, making it an effective UV wavelength for microbial inactivation. 8, 9 The efficacy of decontamination by UVGI depends on several factors, namely, the UVC dose, the pathogen to be inactivated, and the surface or substrate to be decontaminated such that the same pathogen on two different surfaces will require different doses in order to achieve the same level of decontamination. Most studies on UVGI would consider a 3-to 4-log reduction as an adequate level of decontamination. 10 Prior to the COVID-19 pandemic caused by SARS-CoV-2, UVGI had been shown to effectively inactivate coronaviruses, including SARS-CoV, which causes severe acute respiratory syndrome (SARS), and Middle East respiratory syndrome coronavirus (MERS-CoV), with a >5-log reduction on glass cover slips. 11 Another study found that H1N1 influenza A-infected N95 FFRs found a 3-log reduction in viable influenza virus after a UVGI dose of 1 J/cm 2 administered over 60-70 seconds. 12 Knowing these properties of ultraviolet radiation through advances in photobiology coupled with the demand of decontamination methods for the reuse of PPE, specifically N95 FFRs, our photomedicine and photobiology unit explored the role of UVGI in effectively decontaminating N95 FFRs. Safely reusing PPE through surface decontamination methods is vital and even necessary in emergency situations such as the COVID-19 pandemic. However, it should be emphasized that there are significant limitations and potential adverse effects of UVC decontamination methods, and thus, this process of decontamination of respirators should only be implemented during severe shortages of PPE. This perspective paper outlines one center's experience in applying the fundamental concepts of photomedicine directly to the global crisis at hand, providing timely solutions to critical problems including shortages of PPE during this pandemic. During the height of the pandemic, the photomedicine and photobiology unit at Henry Ford Health System proposed a potential method for respirator decontamination with UVGI. Working closely with The Daavlin Company, a major manufacturer of phototherapy devices, our group repurposed a UVGI unit (referred to as the Daavlin 1 series unit in this manuscript) 13 for decontamination and emphasized that the minimum dose of UVC for proper decontamination should be at least 1 J/cm 2 to each side. This was corroborated by N95Decon, an international volunteer collective of scientists, engineers, clinicians, and students focused on gathering and disseminating information on the protection of respirators during COVID-19. 14,15 Subsequently, our group performed a study that assessed the minimum dose received by various parts of the N95 respirator after one complete decontamination cycle with the Daavlin 1 series unit. One complete decontamination cycle consisted of administering a UVC dose of 1.5 J/cm 2 each to the outside-facing and wearer-facing surfaces of the respirator, amounting to a total dose of 3 J/cm 2 to the respirator. This study found that all parts of the respirator surface received a dose of at least 1 J/cm 2 . More globally, this study provides a model by which UVC dose received by different areas of FFRs can be accurately assessed, given differences in UVGI devices and different types of FFRs. 16 Importantly, these decontamination doses are unlikely to be sufficient for all known pathogens but were meant for coverage of the causative agent of the pandemic, SARS-CoV-2. The outside-facing and wearer-facing surfaces of the respirators were each irradiated with a dose of 1.5 J/cm 2 UVC (254 nm). Viable SARS-CoV-2 was quantified by a median tissue culture infectious dose assay (TCID 50 ) and was measured prior to and following UVC. The results of this study showed that UVC delivered using a dose of 1.5 J/cm 2 to each side of the FFR was an effective method of decontamination for the 3M 1860 and Moldex 1511 facepieces and for the straps of 3M 8210 and the Moldex 1511 models-viral concentrations on these models were significantly decreased after UVC. This suggests that this dose of UVC applied to both sides of N95 FFRs effectively decontaminates SARS-CoV-2 on some but not all models of N95 FFRs. 18 We noted that ma- per mL) may generate as many as 1.23 × 10 5 viral copies that remain airborne after 10 seconds, and only 386 viral copies remain airborne after 10 seconds in a patient with a normal viral load (7.00 × 10 6 copies per mL). Thus, the inoculum used in our study (8 × 10 5 viral copies) 18 is higher than the number of SARS-CoV-2 viral copies estimated to be airborne from a cough in this theoretical model. 19 As UVGI becomes increasingly incorporated in health systems throughout the country for the disinfection of N95 FFRs, one must be aware of the adverse effects of UVC exposure on the operator. Overexposure to UVC radiation can cause damage to the cornea and various skin reactions. Lyons et al reported a case of a 50-year-old man with repeated exposure to UVC from a UVGI device who developed erythema and peeling after 4 days. The exposure was unintentional; dose of UVGI was 1.5 J/cm 2 , and the patient was exposed to approximately 30 rounds of radiation. 20 Another case report describes a 90-minute accidental exposure to UVC radiation in 26 medical school students; all of whom reported ocular symptoms, diagnosed as photokeratitis, and varying skin symptoms (erythema, burning sensation, irritation, and pain) followed by desquamation. 21 Since UVC is filtered out by the atmosphere, the effects from longterm exposure to UVC are largely unknown. Given that UVC may lead to adverse cutaneous and ocular adverse reactions, our group also conducted a study to determine whether sunscreens, UV goggles, and surgical mask face shields minimize UVC exposure from UVGI devices. The study measured the irradiance of a UVGI unit with a UVC light radiometer, with different sunscreens, UV goggles, and a surgical mask face shield. The study showed that the three tested sunscreens, UV goggles, and surgical mask face shields all protected against UVC irradiation, which would consequently protect against the side effects. 22 Thus, it is recommended that those operating UVC devices wear a broad-spectrum SPF 30 or above sunscreen and wear eye protection in the form of UV goggles or a surgical mask face shield to protect against UVCinduced skin and eye damage. Our group explored other wavelengths of electromagnetic radiation ranging from other types of ultraviolet radiation to infrared radiation for their decontamination potential. In a review by Horton et al, 10 our group extrapolated the dose of radiation needed at each wavelength to achieve a (1/e) 67% reduction in viral load, based on a composite UVA/UVB action spectrum by Lytle and Sagripanti 23 We reported that if it takes 1 J/cm 2 of 254 nm UVC for 1/e reduction in a given pathogen at a given substrate, then it will take approximately 1.5 J/cm 2 at 280 nm, 3.3 J/cm 2 at 290 nm, 33.3 J/cm 2 at 300 nm, and so on-meaning higher doses are needed at higher wavelengths, in order to attain the same level of decontamination. Of note, actual doses required for 1/e reduction will be much lower than 1 J/cm 2 at 254 nm and corresponding doses at other wavelengths can be scaled down accordingly. This review indicated that while UVB, UVA, visible light, and infrared irradiation could decrease viral load, the doses needed would require an impractically long duration of irradiation based on currently available light sources. 10 Through our group's experience with using UVC as a decontamination method for N95 respirators during the COVID-19 pandemic, we noted an important factor to consider with this treatment. We conducted a study to establish the number of irradiation cycles that the respirator can endure before failing fit testing. Our results suggested that fit testing must be done after decontamination as UVGI treatment may degrade polymers in the respirators themselves and impact the elasticity of the bands. 24 In addition, the appropriate minimum dosage can be different for each respirator type, and therefore, the appropriate dose must be determined for each model of N95 FFR. 17 In addition, studies are needed on the different SARS-CoV-2 variants to determine whether there are varying responses to UVGI treatment. The experience of our single center clearly demonstrates the important contribution of photobiology and photomedicine to all specialties of medicine during this pandemic. The unprecedented global pandemic of the novel coronavirus SARS-CoV-2 quickly led to dire shortages of essential PPE for healthcare personnel around the world. Thus, our group initiated an effort to utilize the known germicidal properties of UV irradiation, more specifically UVC in the form of UVGI to decontaminate respirators within Henry Ford Health System. As outlined above, we extrapolated UVC dosing from prior virology work, developed models for dosing UVC irradiation specifically as it relates to decontaminating N95 respirators, tested the effect of the proposed treatment on SARS-CoV-2 inoculated respirators, and explored the side effects of UVC and precautions to take with its use. With such advances, three hospitals decontaminated almost 10 000 respirators from April 7, 2020 to July 2, 2020, which were then returned for reuse to their original frontline healthcare workers. The current global health crisis has created a need for creative solutions for unprecedented problems, and our group used the abundance of knowledge and research in photobiology and photomedicine to construct one. The authors wish to acknowledge the important partnership with Bob Goldin and The Daavlin Company in developing the desktop UVGI device. None declared. Data sharing not applicable to this article as no datasets were generated or analysed during the current study. https://orcid.org/0000-0002-2316-6375 Angeli Eloise Torres https://orcid.org/0000-0002-9551-2118 COVID-19 decontamination and reuse of Filtering Facepiece Respirators Filtration efficiency of hospital face mask alternatives available for use during the COVID-19 pandemic Filtration efficiency, effectiveness, and availability of N95 face masks for COVID-19 prevention Ultraviolet Germicidal Irradiation Handbook: UVGI for Air and Surface Disinfection Evaluation of an ultraviolet C (UVC) light-emitting device for disinfection of high touch surfaces in hospital critical areas Disinfectant activity of a portable ultraviolet C equipment Ultraviolet-C and other methods of decontamination of filtering facepiece N-95 respirators during the COVID-19 pandemic Ultraviolet irradiation doses for coronavirus inactivation -review and analysis of coronavirus photoinactivation studies The history of ultraviolet germicidal irradiation for air disinfection Spectrum of virucidal activity from ultraviolet to infrared radiation Efficacy of an automated multiple emitter whole-room ultraviolet-C disinfection system against coronaviruses MHV and MERS-CoV Ultraviolet germicidal irradiation of influenza-contaminated N95 filtering facepiece respirators Ultraviolet germicidal irradiation: Possible method for respirator disinfection to facilitate reuse during the COVID-19 pandemic The importance of the minimum dosage necessary for UVC decontamination of N95 respirators during the COVID-19 pandemic Technical Report for UV-C-Based N95 Reuse Risk Management. N95Decon Research Document UVC germicidal units: determination of dose received and parameters to be considered for N95 respirator decontamination and reuse Effectiveness of N95 respirator decontamination and reuse against SARS-CoV-2 virus The effect of ultraviolet C radiation against different N95 respirators inoculated with SARS-CoV-2 Modeling the load of SARS-CoV-2 virus in human expelled particles during coughing and speaking Ultraviolet C-induced skin reaction from ultraviolet germicidal irradiation of N95 respirators during the COVID-19 pandemic Unusual high exposure to ultraviolet-C radiation Skin and eye protection against ultraviolet C from ultraviolet germicidal irradiation devices during the COVID-19 pandemic Predicted inactivation of viruses of relevance to biodefense by solar radiation The importance of fit testing in decontamination of N95 respirators: a cautionary note The value of photomedicine in a global health crisis: Utilizing ultraviolet C to decontaminate N95 respirators during the COVID-19 pandemic