key: cord-0876622-g3wj7m6y authors: Cheng, Vincent Chi-Chung; Lung, David Christopher; Wong, Shuk-Ching; Au, Albert Ka-Wing; Wang, Qun; Chen, Hong; Xin, Li; Chu, Allen Wing-Ho; Ip, Jonathan Daniel; Chan, Wan-Mui; Tsoi, Hoi-Wah; Tse, Herman; Ng, Ken Ho-Leung; Kwan, Mike Yat-Wah; Chuang, Shuk-Kwan; To, Kelvin Kai-Wang; Li, Yuguo; Yuen, Kwok-Yung title: Outbreak investigation of airborne transmission of Omicron (B.1.1.529) - SARS-CoV-2 Variant of Concern in a restaurant: implication for enhancement of indoor air dilution date: 2022-02-16 journal: J Hazard Mater DOI: 10.1016/j.jhazmat.2022.128504 sha: 993b4882d68ed0f6a64c83ac6c191128b1d5d8cc doc_id: 876622 cord_uid: g3wj7m6y Airborne transmission of SARS-CoV-2 has been increasingly recognized in the outbreak of COVID-19, especially during the emergence of Omicron variant. We investigated an outbreak due to Omicron variant in a restaurant. Besides the epidemiological and phylogenetic analysis, the secondary attack rates of customers of restaurant-related COVID-19 before (outbreak R1) and after enhancement of indoor air dilution (outbreak R2) were compared. On 27(th)December 2021, an index case attended restaurant R2 for 98 minutes. Except for 1 sitting in the same table, six other secondary cases sat in 3 corners at 3 different zones, where designated staff served customers at different zones. The median exposure time was 34 minutes (range:19-98 minutes). All 7 secondary cases were phylogenetically related to the index. Smoke test demonstrated the airflow direction airflow which explained the distribution of secondary cases. Compared with an earlier COVID-19 outbreak in another restaurant R1 (19(th)February 2021), just preceding the mandatory requirement of enhancement of indoor air dilution, the secondary attack rates among customers in R2 was significantly lower than that in R1 (3.4%,7/207vs 28.9%,22/76,p<0.001). Enhancement of indoor air dilution including ventilation and installation of air purifier and upper-room ultraviolet-C germicidal irradiation could minimize the risk of SARS-CoV-2 transmission in the restaurant. The Coronavirus Disease 2019 pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is the most devastating emerging infectious disease in the 21 st century. The cumulative number of infected cases had already exceeded 278 million with almost 5.4 million deaths as of 26 th December 2021. 1 The case number further increased steeply after the report of Omicron (B.1.1.529) -SARS-CoV-2 variant of concern. 2 Although the severity of disease caused by Omicron variant appeared to be decreased compared with the previously reported variants of concern, 3 probably due to the less efficient replication and virus-cell fusion than Delta variant as shown in transmembrane serine protease 2-overexpressing VeroE6 cells, 4 The effective reproduction number of Omicron is 3 times greater than that of Delta under the same epidemiological conditons, 5 which may be related to the potential of better airborne transmissibility 6 , epidemic fatigue of the public and decreased compliance to control measures, and reduced neutralizing antibody against the Omicron variant in the vaccine recipients. 7 In Hong Kong, we adopted stringent measures on border control and required all inbound travelers arriving at the Hong Kong International Airport (HKIA) to undergo compulsory quarantine in the designated quarantine hotels for up to 21 days, except for the air crew who were allowed to be quarantined at home if the first COVID-19 test was negative for SARS-CoV-2 by reverse transcription polymerase chain reaction (RT-PCR) at the HKIA. With these measures, there was no community outbreak of COVID-19 when the fourth wave of COVID-19 came to the end on April 2021. Despite some sporadic episodes of SARS-CoV-2 transmission in the designated quarantine hotels between quarantinees, 8, 9 these did not result in a new wave of COVID-19 in our community. 10 J o u r n a l P r e -p r o o f 4 However, the risk of Omicron variant transmission remains substantial in Hong Kong because of the potential risk from quarantine exemption of air crew in the designated hotel. The risk of SARS-CoV-2 transmission is even higher in the indoor areas, especially when the air crew members carrying Omicron variant visit eateries and bars where people take off their masks during drinking and dining. In March 2021, the Hong Kong Special Administrative Region Government legislated on the requirement on air change or air purifier in the seating area of dine in catering premises to reduce the risk of indoor SARS-CoV-2 transmission. 11 In brief, catering business operators require to attain an air change per hour (ACH) at 6 or above in the seating area. Otherwise air purifiers are to be installed as an alternative measure to reduce the risk of airborne transmission of SARS-CoV-2. 12 Here, our aim is to report a COVID-19 outbreak due to Omicron variant in a restaurant with a relatively lower secondary attack rate possibly as a result of indoor air dilution enhancement by installation of ultraviolet-C air purifying system. Since the official announcement of the outbreak of community acquired pneumonia in Wuhan, Hubei Province on 31 st December 2019 (day 1), 13 rapid and dynamic public health and infection control measures were implemented in the community and hospitals in response to the evolving epidemic to minimize the number of COVID-19 infection. [14] [15] [16] [17] [18] Each COVID-19 case, regardless of symptomatic or asymptomatic, was investigated for the potential source of acquisition. The epidemiological information found was uploaded to the website of the The epidemiology of COVID-19 cases was analyzed, especially for those patients who had acquired the infection from the restaurants during the evolving COVID-19 pandemic in Hong Kong. Outbreak investigation was specifically conducted to understand the risk of acquisition of Omicron variant in the restaurant (Outbreak R2). The secondary attack rate of this current episode was compared with the preceding COVID-19 outbreak in a restaurant (Outbreak R1) on 19 th February 2021. Outbreak R1 occurred in a period prior to the mandatory implementation of enhancement of air dilution. Estimation of quanta generation in outbreak R2 and R1 was carried out by using a steady-state mathematical model to describe the transmission of airborne infectious diseases, which is known as the Wells-Riley equation. 20 The volume of air and the air change rate were measured to calculate the virus-free air in R2 and R1. An aerosol deposition rate of 0.30 h −1 and virus deactivation rate of 0.63 h −1 were adopted as described previously. 21 The pulmonary flow rate per susceptible person of 0.15 L/s was used for the estimation. The median duration of exposure to the infectious case among the susceptible person was recorded. J o u r n a l P r e -p r o o f 6 This is a descriptive epidemiological study to evaluate the effect of enhancement of air dilution in the restaurant on the secondary attack rate during COVID-19 outbreak. For the air crew who was required to undergo compulsory testing for COVID-19 in the community testing centers, those symptomatic patients, and asymptomatic persons who were tested for contact tracing due to potential exposure to a COVID-19 confirmed case, combined nasal and throat swabs were collected by staff with medical and healthcare training in the community testing centers, or inside the hospitals including the newly built temporary hospital adjacent to the community treatment facility at AsiaWorld-Expo in Hong Kong. Respiratory specimens such as nasopharyngeal swabs, throat swabs, and sputum were collected for serial monitoring of viral load by RT-PCR upon hospitalization. Deep throat saliva was accepted as an alternative specimen. 22 Whole genome sequencing was performed directly on respiratory specimens or deep throat saliva from laboratory-confirmed COVID-19 cases. This study was approved by the Institutional Review Board of The University of Hong Kong/Hospital Authority Hong Kong West Hospital Cluster. Whole-genome sequencing of SARS-CoV-2 was performed using Nanopore sequencing technology (Oxford Nanopore Technologies, Oxford, UK) as we previously described. 23 Briefly, RNA extracted from respiratory specimens by QIAamp Viral RNA Kit The sequences were first aligned using MAFFT. 25 The maximum-likelihood whole genome phylogenetic tree was constructed using IQTREE. 26 The best fit substitution model was chosen automatically according to the bayesian information criterion score (BIC). Then 1000 ultrafast bootstraps were applied to calculate the final tree. The unrelated substructures of the tree with branch length representing mutation count of less than 1 were removed using the -czb option. Finally, the SARS-CoV-2 reference genome (accession no.: MN908947.3) is chosen as the outgroup representative. Differences in the secondary attack rates of SARS-CoV-2 acquisition in the restaurants were evaluated between outbreak R1 and R2 which occurred before and after the implementation of enhancement measure of indoor air dilution, in particular in persons with or without wearing masks, using Chi-square test or Fisher exact test for categorical variables. Statistical analyses were performed using IBM SPSS Statistics (version 26). A two-sided pvalue of < 0.05 was considered statistically significant. The funding sources had no role in the study design, data collection, analysis, interpretation, or writing of the report. The corresponding author had full access to all data in the study and had the final responsibility for the decision to submit for publication. Based on the record on dining table reservation, credit card payment, and closed-circuit television of R2, a total of 207 persons who attended the restaurant for lunch were exposed to the index case between 13:00 to 15:00, 27 th December 2021. They, together with 22 staff serving at R2, were sent to quarantine camp for observation. Review of closed-circuit television showed that the index case did not leave the seat during the entire duration of lunch. Outbreak R2 involved 7 secondary cases of Omicron variant, who were diagnosed during the quarantine period (Table 1) . Of these 7 secondary cases, the median age was 50 years (range: 13 to 76 years). Symptomatic infection was observed in 5 (71.4%) of 7 cases, with the median onset 5 days after exposure (range: 3 to 7 days after exposure). All of them had completed 2 doses of COVID-19 vaccine at a median of 164 days prior to exposure (range: 129 to 238 days). All secondary cases were customers who did not wear masks while staying in the dining area of R2, resulting in a secondary attack rate of 3.4% (7 / 207) among the customers ( Table 2 ). The restaurant R2 (245 m 2 , 0.84 customer per m 2 ) is adjacent to another restaurant R3 (70 m 2 ), where they are interconnected by a doorway in the middle, but have separate entrance and kitchen. The primary air handling unit (PAU) is located at R3, and fresh air is distributed to the R3 and R2. The PAU rate capacity was 5400 m 3 /hour, and designated ACH for the whole premises is equivalent to 5.7. Following the on-site measurement of the outdoor air supply in air ducts on 30 th December 2021 in R2, the ACH in the seating area was 2.0. Ultraviolet-C air purifier system was installed in R2 to comply with Hong Kong legal requirement. 27 The improvement of indoor air dilution with installation of air purifiers and upperroom ultraviolet-C germicidal irradiation significantly decreased the secondary attack rate during COVID-19 outbreak among the customers in the Chinese restaurants ( Table 2 ). The number of restaurant clustering per 100 episodes of exposure by COVID-19 patients was inversely related to the number of air purifiers being installed in the restaurants ( Figure 5 ). Given the aerosol deposition rate (0.30 h −1 ), virus deactivation rate (0.63 h − 1 ), and the pulmonary flow rate per susceptible person (0.15 L/s) in R2 and R1, the quanta generation rate was estimated in R2 and R1. In R2, the virus-free air was 2530.2 L/s. Of 207 customers, J o u r n a l P r e -p r o o f 11 7 infected secondary cases were exposed with a median of 0.57 h. The estimated quanta generation rate was 1023.4 quanta per h in R2. In R1, the virus-free air was 232.5 L/s. Of 76 customers, 22 infected secondary cases were exposed with a median of 0.95 h. The estimated quanta generation rate was 557.7 quanta per h in R2. Whole genome sequencing was performed for the 8 cases in the cluster in R2 ( Figure 6 ). Phylogenetic tree showed that they clustered together. Four cases had identical sequence With the evolution of COVID-19 pandemic, there has been increasing evidence of airborne transmission of SARS-CoV-2, 28 especially in the poorly ventilated indoor areas. [29] [30] [31] Dining places and bars were considered as the high-risk area for COVID-19 outbreaks as people may interact closely without wearing masks. [32] [33] [34] In fact, social gathering with maskoff activities has been shown to increase the risk of SARS-CoV-2 transmission during the early phase of COVID-19 pandemic. 14 In Hong Kong, the first community outbreak of COVID-19 with superspreading event was attributed to the family gathering and dining in a commercial party room. 35 Before the implementation of enhanced indoor air dilution, the overall secondary attack rate of COVID-19 in outbreak R1 (33.4%) was two times higher than that of the household contacts. 38 The postulation of airborne transmission of SARS-CoV-2 may not fully explain the unusually high secondary attack rate among the restaurant staff as they were supposed to wear masks all the time at work. Wearing mask in the healthcare setting has already been shown to minimize the nosocomial transmission of respiratory viruses. 39 Presumably, these cases were phylogenetically related. However, case 7, a 13-year old girl had two nucleotide differences compared with the index case, and also had one nucleotide difference with case 4, who was her mother, sitting in Table 95 However, extra costs are required for energy consumption and materials of upgrading heating and ventilation systems to reduce infection risk. 44 In the modern heating, ventilation, and air conditioning systems, increasing ventilation can be overly costly with limited benefit since indoor air must be maintained at a given temperature and humidity, while improving filtration may deliver more benefit with less cost. There are several limitations in this study. First, we are not able to compare the secondary attack rates of all COVID-19 outbreaks in the restaurants in Hong Kong. It is because the practice of contact tracing has been evolving during the COVID-19 pandemic that not all exposed persons in the restaurants were quarantined in the initial phase of COVID-19. Secondly, the epidemiological background of two outbreaks in R1 and R2 may be heterogeneous in terms of the area occupied per customer, vaccination rate among the secondary cases, and more importantly, the difference in SARS-CoV-2 variants. All Table A2 . ☐ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. ☒ The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Vincent Chi-Chung CHENG reports financial support was provided by Government of the Hong Kong Special Administrative Region of the People. World Health Organization SARS-CoV-2 Variant of Concern. World Health Organization Decreased severity of disease during the first global omicron variant covid-19 outbreak in a large hospital in tshwane, south africa SARS-CoV-2 Omicron variant shows less efficient replication and fusion activity when compared with delta variant in TMPRSS2-expressed cells Relative Instantaneous Reproduction Number of Omicron SARS-CoV-2 variant with respect to the Delta variant in Denmark A spatiotemporally resolved infection risk model for airborne transmission of COVID-19 variants in indoor spaces Neutralization of SARS-CoV-2 Omicron variant by sera from BNT162b2 or Coronavac vaccine recipients To prevent SARS-CoV-2 transmission in designated quarantine hotel for travelers: Is the ventilation system a concern? Indoor Air Transmission of Omicron (B.1.1.529) -SARS-CoV-2 Variant of Concern in a designated quarantine hotel for travelers: a challenge of elimination strategy of COVID-19. Lancet Reg Health West Pac Complementation of contact tracing by mass testing for successful containment of beta COVID-19 variant (SARS-CoV-2 VOC B.1.351) epidemic in Hong Kong Air change / Installation of Air Purifier in Catering Premises. Food and Environmental Hygiene Department. The Government of Hong Kong Special Administrative Region Final Report on Compliance with the Requirement on Air Change or Air Purifiers in Seating Areas of Dine-in Catering Premises under Cap. 599F. Food and Environmental Hygiene Department. The Government of Hong Kong Special Administrative Region The Centre for Health Protection closely monitors cluster of pneumonia cases on Mainland. Press release of the Department of Health The role of community-wide wearing of face mask for control of coronavirus disease 2019 (COVID-19) epidemic due to SARS-CoV-2 Infection control challenge in setting up a temporary test centre at Hong Kong International Airport for rapid diagnosis of COVID-19 due to SARS-CoV-2 Escalating infection control response to the rapidly evolving epidemiology of the coronavirus disease 2019 (COVID-19) due to SARS-CoV-2 in Hong Kong Infection control challenges in setting up community isolation and treatment facilities for patients with coronavirus disease 2019 (COVID-19): Implementation of directly observed environmental disinfection Multipronged infection control strategy to achieve zero nosocomial coronavirus disease 2019 (COVID-19) cases among Hong Kong healthcare workers in the first 300 days of the pandemic Centre for Health Protection. Department of Health. The Government of the Hong Kong Special Administrative Region Airborne spread of measles in a suburban elementary school Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event. Indoor Air Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study Phylogenomic analysis of COVID-19 summer and winter outbreaks in Hong Kong: An observational study. Lancet Reg Health West Pac nCoV-2019 novel coronavirus bioinformatics protocol MAFFT multiple sequence alignment software version 7: improvements in performance and usability IQ-TREE: a fast and effective stochastic algorithm for estimating maximum-likelihood phylogenies Guide on Compliance with Requirement on Air Change / Air Purifiers in Seating Areas of Dine-in Catering Premises. Food and Environmental Hygiene Department. The Government of Hong Kong Special Administrative Region A review on measurements of SARS-CoV-2 genetic material in air in outdoor and indoor environments: Implication for airborne transmission Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) How can airborne transmission of COVID-19 indoors be minimised? Environ Int Airborne concentrations of SARS-CoV-2 in indoor community environments in Italy Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant. Build Environ Evidence for lack of transmission by close contact and surface touch in a restaurant outbreak of COVID-19 Superspreading Event of SARS-CoV-2 Infection at a Bar A superspreading event involving a cluster of 14 coronavirus disease 2019 (COVID-19) infections from a family gathering in Hong Kong Special Administrative Region SAR (China). Western Pac Surveill Response J Poor ventilation worsens short-range airborne transmission of respiratory infection. Indoor Air Insufficient ventilation led to a probable long-range airborne transmission of SARS-CoV-2 on two buses. Build Environ The Household Secondary Attack Rate of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2): A Rapid Review Prevention of nosocomial transmission of swine-origin pandemic influenza virus A/H1N1 by infection control bundle Absence of nosocomial influenza and respiratory syncytial virus infection in the coronavirus disease 2019 (COVID-19) era: Implication of universal masking in hospitals Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19) Airborne transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2): What is the implication of hospital infection control? Infect Control Hosp Epidemiol Nosocomial Outbreak of Coronavirus Disease 2019 by Possible Airborne Transmission Leading to a Superspreading Event Modeling and multiobjective optimization of indoor airborne disease transmission risk and associated energy consumption for building HVAC systems