key: cord-0873586-vg5we1fj authors: Wielick, Constance; Ludwig-Begall, Louisa F.; Dams, Lorène; Razafimahefa, Ravo M.; Demeuldre, Pierre-Francois; Napp, Aurore; Laperre, Jan; Jolois, Olivier; Farnir, Frédéric; Haubruge, Eric; Thiry, Etienne title: The use of germicidal ultraviolet light, vaporised hydrogen peroxide and dry heat to decontaminate face masks and filtering respirators contaminated with an infectious norovirus date: 2021-03-31 journal: Infection Prevention in Practice DOI: 10.1016/j.infpip.2020.100111 sha: ca8529656adcbcf7c5c1ca9f7870047219c8f76d doc_id: 873586 cord_uid: vg5we1fj In the context of the SARS-CoV-2 pandemic, reuse of surgical masks and filtering facepiece respirators has been recommended. Their reuse necessitates procedures to inactivate contaminating human respiratory and oral pathogens. We previously demonstrated decontamination of masks and respirators contaminated with an infectious SARS-CoV-2 surrogate via ultraviolet germicidal irradiation, vaporised hydrogen peroxide, and use of dry heat. Here, we show that these same methods efficiently inactivate a more resistant, non-enveloped oral virus; decontamination of infectious murine norovirus-contaminated masks and respirators reduced viral titres by over four orders of magnitude on mask or respirator coupons. The use of germicidal ultraviolet light, vaporised hydrogen peroxide and dry heat to decontaminate face masks and filtering respirators contaminated with an infectious norovirus In the context of the SARS-CoV-2 pandemic, reuse of surgical masks and filtering facepiece respirators has been recommended. Their reuse necessitates procedures to inactivate contaminating human respiratory and oral pathogens. We previously demonstrated decontamination of masks and respirators contaminated with an infectious SARS-CoV-2 surrogate via ultraviolet germicidal irradiation, vaporised hydrogen peroxide, and use of dry heat. Here, we show that these same methods efficiently inactivate a more resistant, non-enveloped oral virus; decontamination of infectious murine norovirus-contaminated masks and respirators reduced viral titres by over four orders of magnitude on mask or respirator coupons. Abbreviations: FFR, filtering facepiece respirator; SM, surgical mask; MuNoV, murine norovirus; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2. In the context of the ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, the supply of personal protective equipment remains under strain and re-use of surgical face masks (masks) and filtering facepiece respirators (FFRs) has been recommended [1] . Prior decontamination is paramount to safe re-use of these items and must ideally inactivate both SARS-CoV-2 and other contaminating respiratory or oral human pathogens [2] . Human respiratory pathogens include other enveloped corona-, pneumo-, metapneumo-, paramyxo-, and orthomyxoviruses as well as non-enveloped coxsackie-and rhinoviruses; oral pathogens include astro-, picorna-, polio-, rota-and noroviruses (all non-enveloped) [3] . Enveloped viruses, surrounded by an outer lipid layer, are susceptible to harsh environmental conditions and inactivating treatments; nonenveloped viruses are known to be significantly more resistant. The small, non-enveloped human noroviruses (genus Norovirus, family Caliciviridae), recognised as the major global cause of viral gastroenteritis [4] , are notorious for their tenacity in the face of decontamination [5] . The genetically and structurally similar murine norovirus (MuNoV), which replicates efficiently in vitro, has been identified as an appropriate surrogate virus for modelling human norovirus inactivation [6] . We previously demonstrated efficient decontamination of masks and FFRs contaminated with an infectious SARS-CoV-2 surrogate virus via ultraviolet germicidal irradiation, vaporised hydrogen peroxide, and use of dry heat [7] . In the present investigation into decontamination of MuNoV-inoculated masks and FFRs, we show that these same methods efficiently inactivate a more resistant, non-enveloped oral virus. All three methods permit demonstration of a loss of viral infectivity by more than three orders of magnitude in line with the FDA policy regarding face masks and respirators [2] . Inactivation of a norovirus, the most resistant of the respiratory and oral human viruses, can predict the inactivation of any less resistant viral mask or FFR contaminant. Efficacy of three different decontamination methods in inactivating an infectious norovirus was assessed using masks and FFRs experimentally inoculated with MuNoV. Per decontamination method and mask type, one negative control mask or FFR (uncontaminated but treated), three treated masks or FFRs (MuNoV-contaminated and treated), and three positive controls (MuNoV-contaminated but untreated) were utilised. The workflow followed previously described protocols for mask and FFR inoculation, decontamination and virus elution [7] . The murine macrophage cell line RAW264.7 (ATCC TIB-71) was maintained in Dulbecco's modified Eagle's medium (Invitrogen) containing 10% heat inactivated foetal calf serum (FCS) (BioWhittaker), 2% of an association of penicillin (5000 SI units/ ml) and streptomycin (5 mg/ml) (PS, Invitrogen) and 1% 1 M HEPES buffer (pH 7.6) (Invitrogen) at 37 C with 5% CO 2 . Stocks of MuNoV isolate MNV-1.CW1 were produced by infection of RAW264.7 cells at a multiplicity of infection of 0.05. Two days post-infection, cells and supernatant were harvested and clarified by centrifugation for 20 minutes at 1000 x g after three freeze/thaw cycles (e 80 C/37 C). Titres were determined via the tissue culture infective dose (TCID 50 ) method; RAW 264.7 cells were seeded in 96-well plates, infected with 10-fold serial dilutions of MuNoV, incubated for three days at 37 C with 5% CO 2 , and finally stained with 0.2% crystal violet for 30 minutes. Titres, expressed as TCID 50 /ml, were calculated according to the Reed and Muench transformation [8] . A virus stock with a titre of 10 7.06 TCID 50 /ml was used in subsequent steps. Per treated or control mask or FFR, 100 ml of undiluted viral suspension were injected under the first outer layer at the centre of each of three square coupons (34 mm x 34 mm). In addition to inoculation of the de facto masks or FFRs, 100 ml of viral suspension was pipetted onto one elastic strap per contaminated mask or FFR. Masks and FFRs were allowed to dry for 20 minutes at room temperature before decontamination via UV irradiation, vaporised H 2 0 2 , and dry heat. Masks and FFRs were individually UV-irradiated for 2 minutes (2.6J/cm 2 fluence per mask), using a LS-AT-M1 (LASEA Company, Sart Tilman, Belgium). Vaporous hydrogen peroxide (VHP) treatment was performed with the V-PRO Max Sterilizer (Steris, Mentor, OH) which uses 59% liquid H 2 O 2 to generate hydrogen peroxide vapor. A 28-minute non lumen cycle was used, consisting of 2 min 40 sec conditioning (5 g/min), 19 min 47 sec decontamination (2.2 g/min) and 7 min 46 sec aeration (750 ppm peak VHP concentration). Dry heat decontamination was performed at temperatures of 102 C (AE4 C) for 60 min (AE15 min) in an electrically heated vessel (M-Steryl, AMB Ecosteryl Company, Mons, Belgium). Upon completion of the decontamination protocols, MuNoV was eluted from three excised coupons and one severed elastic strap per mask or FFR into 4 mL elution medium (Eagle's DMEM (Sigma)) supplemented with 2 % of an association of penicillin (5000 SI units/mL) and streptomycin (5 mg/mL) (PS, Sigma) and, for elution from VHP-treated materials, 20% FCS and 0.1% b-mercaptoethanol) via 1 minute (coupons) or 20 minute vortex (straps) at maximum speed (2500 rounds per minute; VWR VX-2500 Multi-Tube Vortexer). Titres of infectious MuNoV recovered from individual coupons and straps were determined via TCID 50 assay. Back titrations of inoculum stocks were performed in parallel to each series of decontamination experiments. All statistical analyses were performed using SASÒ software 9.3 (SAS/ETS 12.1 -SAS STAT 12.1). Linear mixed models were studied using the MIXED procedure; in addition, TOBIT models were implemented using the qualitative and limited dependent variable model (QLIM) procedure. All p-values reported using the QLIM procedure were obtained using Wald tests. be within a range of 3.55Â10 7 to 6.31Â10 7 TCID 50 /mL for all experiments. The cell culture limit of detection (LOD) was 0.8 log10 TCID 50 /ml for all analyses except those concerning H 2 O 2 -treated mask-or FFR straps (2.8 log10 TCID 50 /ml) and UV-treated FFR straps (1.8 log10 TCID 50 /ml). High levels of infectious virus were recovered from MuNoVinoculated, untreated coupons of all masks and FFRs, with mean overall recovery values of 4.94 (AE0.55 standard deviation (SD)) log10 TCID 50 /mL. Mean strap recovery values were similar between experiments, however they were lower than coupon recovery values (notable exception: elution from untreated masks), with mean values of 4.11 (AE0.77 SD) log10 TCID 50 /mL ( Figure 1 ). Following mask UV irradiation and dry heat treatment, titres for virus recovered from coupons remained below the assay LOD, showing total loss of infectivity of around four orders of magnitude (3.64 (AE0.28 SD) log10 TCID 50 /mL and 4.06 (AE0.30 SD) log10 TCID 50 /mL, respectively), while titres of virus recovered from H 2 O 2 -vaporised coupons indicated a loss of infectivity of four orders of magnitude (4.06 (AE0.30 SD) log10 TCID 50 /mL). Titres of virus recovered from treated mask straps were reduced by two orders of magnitude post UV irradiation and H 2 O 2 -treatment (2.06 (AE0.29 SD) log10 TCID 50 /mL, and 2.08 (AE0.38 SD) log10 TCID 50 / mL, respectively) and by four orders of magnitude post heattreatment (4.25 (AE0.25 SD) log10 TCID 50 /mL (below LOD)) ( Figure 2) . Decontamination followed a similar pattern of viral inactivation for UV-treated FFR coupons, reducing viral titres by around four orders of magnitude (3.97 (AE0.40 SD) log10 TCID 50 / mL). Following vaporised H 2 O 2 -and dry heat-treatment, titres for virus recovered from coupons showed a loss of infectivity of three orders of magnitude (3.72 (AE0.29 SD) log10 TCID 50 /mL and 3.64 (AE0.66 SD) log10 TCID 50 /mL, respectively). UV-, H 2 O 2and heat-treatment of FFR straps reduced infectivity by to a lesser degree (1.58 (AE0.14 SD) log10 TCID 50 /mL, from 3.38 Figure 1 . Recovery of MuNoV after elution from inoculated, untreated surgical masks and filtering facepiece respirators. Recovery of infectious murine norovirus (MuNoV) from inoculated untreated surgical masks (SM) and filtering facepiece respirators (FFR) was analysed in RAW 264.7 cells. The cell culture limit of detection (LOD) was 0.8 log 10 TCID 50 /mL. Similar levels of virus recovery were detected for left, right and middle (L, R, M) coupons of masks and respirators; recovery efficacy of infectious virus from straps (S) deviated significantly in all analyses from the mean of all coupons (with the exception of extraction from SM straps in the H 2 O 2 assay). Statistical analyses were performed using SASÒ software 9.3 (SAS/ETS 12.1 -SAS STAT 12.1). Linear mixed models were studied using the MIXED procedure; in addition, TOBIT models were implemented using the qualitative and limited dependent variable model (QLIM) procedure. All p-values reported using the QLIM procedure were obtained using Wald tests. P-values were computed to calculate differences between individual coupon values and differences between mean values of all coupons and straps: ***P<0.001, **P<0.01, *P<0.05, and ns is P!0.05. (AE0.14 SD) log10 TCID 50 /mL to below the LOD, 0.75 (AE0.90 SD) log10 TCID 50 /mL and 2.75 (AE0.50 SD) TCID 50 /mL, respectively). This is, to our knowledge, the first description of stable disinfection of surgical masks and FFRs contaminated with an infectious norovirus using UV irradiation, vaporised H 2 O 2 , and dry heat treatment. Here we demonstrate successful recovery of high quantities of infectious MuNoV from inoculated, otherwise untreated masks and FFR coupons. Three decontamination methods, chemical vaporised H 2 O 2 and physical inactivation via UV irradiation and dry heat treatment, successfully reduced infectious loads of MuNoV inoculated under the outer surface layer of mask and FFR coupons by more than three orders of magnitude. Since carrier surfaces likely influence decontamination efficacy, we examined viral inactivation not only on the de facto FFRs or masks, but also on their elastic straps that may become equally contaminated. We compared titres of infectious virus recovered from inoculated, untreated mask or FFR straps and those inoculated and subsequently decontaminated. While all three decontamination methods were successfully validated as they reduced viral loads by at least more than three orders of magnitude, the elevated LOD of UV-treated FFR straps and H 2 O 2 -vaporised mask-and FFR straps prevented detection of higher infectivity losses. Further studies are planned to elucidate these effects, which may potentially be associated either to inherent virucidal properties of or poor elution from the elastic materials. In conclusion, we describe successful validation of three decontamination methods, UV irradiation, vaporised H 2 O 2 , and dry heat treatment, in inactivating an infectious nonenveloped virus in line with the FDA policy regarding face masks and FFRs. The MuNoV surrogate supplements existing data regarding decontamination of surgical masks and FFRs, and both it and the different decontamination methods tested, are easily adaptable to other FFR and mask types, presenting a useful conservative model for stable validation of nonenveloped virus decontamination. , or dry heat treatment was analysed in RAW 264.7 cells. The cell culture limit of detection (LOD) was 0.8 log 10 TCID 50 /ml for all analyses except those concerning H 2 O 2 -treated SM or FFR straps (1.8 and 2.8 log 10 TCID 50 /ml, respectively) and UV-treated FFR straps (1.8 log 10 TCID 50 /ml). Per decontamination method, nine MuNoV-inoculated, decontaminated coupons (n¼9) and three inoculated, decontaminated straps (n¼3) were analysed in parallel to inoculated, untreated, positive control coupons (n¼9) and straps (n¼3). Statistical analyses were performed using SASÒ software 9.3 (SAS/ETS 12.1 -SAS STAT 12.1). Linear mixed models were studied using the MIXED procedure; in addition, TOBIT models were implemented using the qualitative and limited dependent variable model (QLIM) procedure. All p-values reported using the QLIM procedure were obtained using Wald tests; ****P<0.0001; ***P<0.001, **P<0.01, *P<0.05, and ns is P!0.05. Software, Data curation. Eric Haubruge: Methodology, Conceptualization, Funding acquisition, Project administration, Resources, Supervision, Validation. Etienne Thiry: Methodology, Conceptualization, Funding acquisition Rational use of personal protective equipment for coronavirus disease Enforcement policy for face masks and respirators during the coronavirus disease (COVID-19) public health emergency (revised) guidance for industry and food and drug administration staff How long do nosocomial pathogens persist on inanimate surfaces? A systematic review Comparative Virucidal Efficacy of Seven Disinfectants Against Murine Norovirus and Feline Calicivirus, Surrogates of Human Norovirus Intra-family differences in efficacy of inactivation of small, non-enveloped viruses The use of germicidal ultraviolet light, vaporised hydrogen peroxide and dry heat todecontaminate face masks and filtering respirators contaminated with a SARS-CoV-2 surrogate virus A simple method of estimating fifty percent endpoints The authors express their sincere gratitude to Amélie Matton and Frédéric de Meulemeester (AMB Ecosteryl, Mons, Belgium), Axel Kupisiewicz (LASEA, Sart-Tilman, Belgium), Pierre Leonard (Solwalfin, Belgium) for suggestions and technical and administrative support. The authors have no conflicts of interest to disclose. This work was supported by grants from the Walloon Region, Belgium (Project 2010053 -2020-"MASK -Decontamination and reuse of surgical masks and filtering facepiece respirators") and the ULiège Fonds Spéciaux pour la Recherche 2020.