key: cord-0873260-7cwhgqxn authors: Braunstein, Glenn D.; Schwartz, Lori; Hymel, Pamela; Fielding, Jonathan title: False Positive Results With SARS-CoV-2 RT-PCR Tests and How to Evaluate a RT-PCR-Positive Test for the Possibility of a False Positive Result date: 2021-01-06 journal: J Occup Environ Med DOI: 10.1097/jom.0000000000002138 sha: 0f84be2d0f2edd2bd6d904eeee0dfc3629856a4a doc_id: 873260 cord_uid: 7cwhgqxn nan With SARS-CoV-2 RT-PCR Tests and How to Evaluate a RT-PCR-Positive Test for the Possibility of a False Positive Result To the Editor: T he most widely utilized Nucleic Acid Amplification Test (NAAT) to detect SARS-CoV-2 RNA is the reverse transcriptase-polymerase chain reaction (RT-PCR) test, manufactured by many companies targeting one or more genomic regions of the virus. Although there is a several log difference in the sensitivity of the different RT-PCR tests to pick up viral RNA, many have sufficient analytical sensitivity to detect a viral load during the preinfectious stage in infected individuals. [1] [2] [3] [4] [5] [6] However, none of the tests have sufficient clinical sensitivity to detect virus during the first several days after infection, nor are they 100% sensitive at the time of peak infectiveness. 7, 8 Much has been written about the issue of false negative RT-PCR tests in symptomatic, presymptomatic, and asymptomatic persons infected with the virus. 7, 8 Less has been published about the problem of false positive RT-PCR or other NAAT tests. In the United States, because of a shortage of tests and testing facilities during the early months of the pandemic tests were primarily used for diagnoses to identify a person with an active infection associated with signs or symptoms of COVID-19 or who had definite or suspected recent exposure to the virus. 9 Later, the Federal Drug Administration (FDA) approved testing to be extended to screen for infection in individuals without known or suspected exposure to SARS-CoV-2 living in congregate settings, such as long-term care facilities or prisons. 9 Finally, periodic screening programs have been developed for educational institutions, sport teams, and the workplace to detect asymptomatic, presymptomatic, and symptomatic infected individuals early and isolate them to reduce them infecting others. The overall accuracy of a RT-PCR test is based upon its sensitivity representing the ability to detect infected individuals and the specificity, which is the percentage of uninfected people who test negative. The FDA has published recommendations concerning the data and information that test manufacturers should supply in their application for Emergency Use Authorization (EUA). 10 For analytical specificity they ask for in vitro cross-reactivity studies to demonstrate that the test does not react with related pathogens, high prevalence disease agents, and normal or pathogenic flora that are reasonably likely to be encountered in a clinical specimen. 11 Many of the RT-PCR assays have a 100% sensitivity in this analysis as reported by the manufacturers. 12 For clinical evaluation, the FDA recommends testing 30 positive clinical samples and 30 individual negative samples and comparing the results of the test under consideration to an existing EUA RT-PCR test of high sensitivity. Acceptable clinical performance is defined as a minimum 95% positive and negative percent agreement (PPA and NPA). For a screening indication, the PPA recommendation remains at more than or equal to 95% and the NPA is raised to more than or equal to 98% to reduce false positive test results. 11 In actual use, the clinical sensitivity and specificity of many of these tests is lower in part because of issues surrounding sample collection, handling, and analysis. 8, 12, 13 The performance of these tests when deployed depends not only on their clinical sensitivities and specificities, but also the prevalence of SARS-CoV-2 infections in the setting in which the test is being used. If we consider a test that conforms to the FDA's recommendations for performance in a diagnostic (95% sensitivity and specificity) or screening setting (95% sensitivity, 98% specificity), we can compare its ideal clinical performance when the prevalence of active infection may be 10% (a diagnostic setting) and a prevalence of 1%, as may be found in a screening program. In the diagnostic example, for every 10,000 individuals there will be 1000 infected and 9000 uninfected persons. Of the infected persons, 950 will be detected by the test (true positives) and 50 will be missed (false negatives). For the 9000 uninfected people, 8820 will correctly have negative tests (true negatives) and 180 will be positive (false positive). The positive predictive value (PPV) is the proportion of all positive tests that are true positives, in this case 950/(950 + 180) or 84%. Thus, most of the positive tests are true positives. Doing these same calculations for the screening scenario, 100 of the 10,000 individuals are infected and 9900 are not. The test will detect 95 of the infected persons and five will be falsely negative. For those who are not infected, 9702 will be correctly diagnosed and 198 will be false positives. The PPV is 95/95 + 198 or 32.4%. In this case, 2/3 of the positive results are false positives. For a prevalence of 0.1%, the PPV drops to 4.5%. Table 1 lists various factors that have been documented to contribute to falsepositive RT-PCR results. 12,14 -19 Based upon our own experience in investigating groups of false-positive RT-PCR results and discussions with laboratory directors, the two most common problems are contamination and determining the cut-off for stating that a specimen is positive with a low viral load versus being called indeterminate or equivocal. The WHO, and an international consortium of experts have addressed these issues and have produced a checklist for laboratories to reduce possible causes of false-positive RT-PCR results and how to handle equivocal results. 19, 20 The overdiagnosis of SARS-CoV-2 infection has multiple potential adverse effects ( Table 2) 12, 21 : the inconvenience, financial, and psychological issues affecting those misdiagnosed; the possible exposure of uninfected individuals to infected people in hospital or congregate living areas; misdiagnosed persons foregoing social distancing and the masks use because they think that they are immune from COVID-19; and temporary closure of a business because of the need to quarantine coworkers. In addition, the overdiagnosis can inflate the number of asymptomatic infections in public health statistics. Recognizing that a positive RT-PCR result may be a false positive may be difficult. If a RT-PCR-positive individual has signs or symptoms of COVID-19 or has had exposure to somebody who has been shown or suspected of harboring the virus, it is prudent to assume that the result is a true positive, as has been the recommendation of the WHO and the Centers for Disease Control. 24, 25 However, in an asymptomatic individual without known close contact with an infectious individual, especially in a low prevalence setting, the finding of a positive RT-PCR test result should raise the possibility that the result is a false positive. ''Red flags'' that should alert the laboratory personnel include finding an acute rise in the percentage of positive results in comparison to the days and weeks before for all of the samples run in the lab or from a particular collection site, noting that multiple positive samples were in close proximity on the plates in the PCR platform, or finding that the high volume of positive samples exhibit high cycle time (Ct) values that could be associated with a low viral load or issues affecting the cutoff for calling a sample positive, indeterminate, or negative. 19, 20 In these situations, the laboratory should re-extract the original sample and rerun it on the original PCR platform or a different platform with a similar sensitivity. If this cannot be done, a new sample should be obtained and tested. 19, 20 We have examined the issue of false positive results in a screening setting for a segment of the entertainment industry. The various unions that represent members involved in studio and TV productions have provided guidelines for testing and other safety measures in a publication, The Safe Way Forward. 26 They have divided productions into several zones each with their own PCR testing requirements from testing three times a week to testing every 2 weeks. From September 27 through December 5, 2020, The Walt Disney Company performed 122,300 PCR tests at TV production sites, of which 323 were positive (0.26%). After removing the 84 positive tests found during the pre-employment screening, which leads to the individual entering isolation and not working on a production, the positivity rate during production was 0.19%. This rate is low in comparison to the average US rate during that same period (4.1% to 10.5%) 27 because members are in a screening program and tested frequently. Also, the studios have instituted strict safety measures. 26 In some, but not all instances, an unexpected positive result in an asymptomatic cast or crew member who had prior negative PCR tests, led to an evaluation of whether the test was a false positive by retesting the person 24 or more hours after the positive test on at least two occasions. If both retests were negative, we considered the first test to be a false positive. Of the 239 positive tests found after the pre-employment tests were removed, 54 (22.6%) were deemed to be false positives, giving a positive predictive value of 77.4%. An important caveat to these numbers is that there was a selection bias in who was investigated for the possibility of a false positive result. As noted, all the individuals were asymptomatic and had at least a negative pre-employment test, and many had multiple negative PCR tests before a positive appeared. Also, there were ''outbreaks'' of positive tests due to documented contamination of reagents or mistakes in programing of the PCR platform. Finding multiple asymptomatic individuals who may not have been in contact with each other led to retesting of the original nasal swabs and testing of freshly obtained new specimens. Since we did not systematically reevaluate every positive test, we may have underestimated the false positive rate. Our experience and the data reviewed above has led us to develop an algorithm for Unnecessary isolation of individuals and quarantining of close contacts with financial and psychological strains 16, 22 Unnecessary contact tracing and testing 23 Wasteful consumption of personal protective equipment Delays in surgical or other procedures 16, 23 Prolong hospital stays 16, 23 with wasteful consumption of PPE Potentially harboring uninfected individuals with infected individuals in hospitals and congregate living areas with possible nosocomial infection 16, 22 Possible exposure to inappropriate medical treatment Individual given false sense of security about immunity so may not follow public health guidelines or receive vaccination Impede correct diagnosis of patients with symptoms Overdiagnosis may distort epidemiologic statistics by including false-positives to estimate prevalence, hospitalization, and death rates as well as modeling (eg, some individuals classified as asymptomatic carriers may actually had a false positive test) PPE, Personal Protective Equipment. 15 Extraction (eg, aerosolization in containment hood) PCR amplification Production of Lab Reagents (eg, manufacturers of the positive control may have contaminated other reagents produced in the same facility; contamination of other consumables) [17] [18] [19] Contamination of the equipment by high viral titer specimens (eg, sample carryover) 16 Cross-reaction with other viruses (eg, other coronaviruses) Sample mix-ups Software problems Data entry or transmission errors Miscommunicating results Variations in parameters around the LOD and definition of an indeterminate result 14, 16, 20 Assuming that an indeterminate result is a positive Non-specific reactions 15 LOD, limit of detection; RT-PCR, reverse transcriptase-polymerase chain reaction. evaluating an unexpected positive result in an asymptomatic individual without known close contact with an actively infected person in a screening setting for the entertainment industry (Fig. 1) . We feel that this algorithm should be applicable to any screening situation and conforms to the recommendation of the WHO, the United Kingdom, and the Norwegian Institute of Public Health, 20, 28, 29 as well as multiple authors. 12, 15, 21, 30, 31 In summary, we have provided additional evidence that false positive SARS-CoV-2 PCR test results do occur in the clinical setting and are especially a problem in a low prevalence screening situation where the prior probability of a positive test is low. Although it is acknowledged that resource limitations may constrain the amount of retesting performed, we posit that the human and economic costs of considering all positive results to be definitive evidence of infection warrant an evaluation for the possibility that the result is falsely positive in an asymptomatic individual without known exposure to an actively infected person. CoV-2 reference panel comparative data, current as of 12/2/2020 Predicting infectious severe acute respiratory syndrome coronavirus 2 from diagnostic samples Correlation between 3790 qPCR positive samples and positive cell cultures including 1941 SARS-CoV-2 isolates Duration of infectiousness and correlation with RT-PCR cycle threshold values in cases of COVID-19 SARS-CoV-2 viral dynamics in acute infections Rethinking Covid-19 test sensitivity-a strategy for containment Variation in false-negative rate of reverse transcriptase polymerase chain reaction-based SARS-CoV-2 tests by time since exposure False negative tests for SARS-CoV-2 infectionchallenges and implications Testing overview Immediately in effect guidance for clinical laboratories, commercial manufacturers, and Food and Drug Administration staff Molecular diagnostic template for commercial manufacturers Diagnosing SARS-CoV-2 infection: the danger of over-reliance on positive test results. False positive test results impact clinical and policy decisions Impact of false-positives and false-negatives in the UK's COVID-19 RT-PCR testing programme On behalf of the RECOVER project and collaborating networks. International external quality assessment for SARS-CoV-2 molecular detection and survey on clinical laboratory preparedness during the COVID-19 pandemic Specificity and positive predictive value of SARS-CV-2 nucleic acid amplification testing in a low-prevalence setting False-positive reverse transcriptase polymerase chain reaction screening for SARS-CoV-2 in the setting of urgent head and neck surgery and otolaryngologic emergencies during the pandemic: clinical implications Pitfalls in SARS-CoV-2 diagnostics Delayed laboratory response to COVID-19 caused by molecular diagnostic contamination Cautionary note on contamination of reagents used for molecular detection of SARS-CoV-2 Diagnostic testing for SARS-CoV-2. Interim guidance False-positive COVID-19 results: hidden problems and costs Israeli lab to stop coronavirus testing after dozens misdiagnosed. Dozens of elderly people from two different nursing homes received false positives Covid-19 testing, low prevalence, and the impact of false positive results Who COVID-19 case definition COVID-19). 2020 interim case definition The Safe Way Forward. A joint report of the DGA, SAG-AFTRA, IATSE and Teamsters' Committees for COVID-19 safety Guidelines Assurance of SARS-CoV-2 RNA positive results during periods of low prevalence Test criteria for coronavirus Testing for coronavirus (SARS-CoV-2) infection in populations with low infection prevalence: the largely ignored problem of false positives and the value of repeat testing SARS-CoV-2 mass testing endangers residents of long-term care facilities