key: cord-0873107-dretlm2r authors: Lan, Dong-Ying; Zhang, Hua; Wu, Ting-Wei; Lü, Fan; Shao, Li-Ming; He, Pin-Jing title: Repercussions of clinical waste co-incineration in municipal solid waste incinerator during COVID-19 pandemic date: 2021-09-15 journal: J Hazard Mater DOI: 10.1016/j.jhazmat.2021.127144 sha: f9de708f614d3011ed74b016896ed012a4721151 doc_id: 873107 cord_uid: dretlm2r During coronavirus disease 2019 pandemic, the exponential increase in clinical waste (CW) generation has caused immense burden to CW treatment facilities. Co-incineration of CW in municipal solid waste incinerator (MSWI) is an emergency treatment method. A material flow model was developed to estimate the change in feedstock characteristics and resulting acid gas emission under different CW co-incineration ratios. The ash contents and lower heating values of the feedstocks, as well as HCl concentrations in flue gas showed an upward trend. Subsequently, 72 incineration residue samples were collected from a MSWI performing co-incineration (CW ratio <10 wt%) in Wuhan city, China, followed by 20 incineration residues samples from waste that were not co-incineration. The results showed that the contents of major elements and non-volatile heavy metals in the air pollution control residues increased during co-incineration but were within the reported ranges, whereas those in the bottom ashes revealed no significant changes. The impact of CW co-incineration at a ratio <10 wt% on the distribution of elements in the incineration residues was not significant. However, increase in alkali metals and HCl in flue gas may cause potential boiler corrosion. These results provide valuable insights into pollution control in MSWI during pandemic. Coronavirus disease 2019 (COVID- 19) is an acute respiratory disease that emerged in late 2019, resulting in a pandemic [1] . According to the World Health Organization report, COVID-19 has affected 223 countries with around 174 million confirmed infected cases and 3.7 million deaths until June 11, 2021 [2] . During such an outbreak, a substantial amount of clinical waste (CW) has been generated [3] . Due to the vast consumption of clinical resources and personal protective equipment to mitigate the pandemic, the CW generation rates of confirmed and suspected cases have been predicted to be 3.2 and 1.8 kg/(bed × day), respectively, which are 4-and 2-fold higher than those of patients with other diseases (0.8 kg/(bed × day)) [4] . For example, the daily generation of CW in Wuhan city in March 2020 was 5-fold higher than that in March 2019 [5] . In addition, domestic waste produced by emergency medical centers and quarantine points are often processed as CW owing to their potential infection hazard [6] . A previous investigation indicated the strong stability of coronavirus on the surfaces of plastics and stainless steel for up to 72 h, and on cardboard surfaces for up to 48 h [7] . Therefore, environment-friendly treatment and disposal of CW is essential to protect human health during COVID-19 outbreak. The sharp increase in CW generation threatens to overwhelm local treatment capacity. To address the overflow of CW, co-incineration in municipal solid waste incinerator (MSWI) is an emergency option and a feasible choice because grate incinerator with high heat transfer rate and operating temperature (> 850 C) guarantees reliable destruction of pathogens [8] . At the same time, the decline in the generation of municipal solid waste (MSW) during the pandemic provides sufficient CW treatment capacity. Nevertheless, information about the risks arising from co-incineration, such as production and emission of secondary pollutants is limited. The nature and composition of CW significantly vary from those of MSW, and specific CW often contains materials with high lower heating values (LHV) and ash contents (e.g., metals) [8, 9] . Meanwhile, the use of plastic products, such as personal J o u r n a l P r e -p r o o f protective equipment (gloves, masks, and protective gown) [10] , which are essential to reduce the transmission of this highly contagious virus, has raised attention owing to the resulting increase in the proportion of plastic waste in CW [3, 9, 11] . Thus, inappropriate operation of co-incineration may cause incomplete combustion [8] , enhancing the emission of aromatic compounds and acid gases as well as generating residue of unacceptable quality. The main aim of this study was to quantitatively evaluate the potential impacts of CW co-incineration in MSWI. First, the various compositions and properties of CW and MSW, as well as the co-incineration ratios of CW treated in MSWI were examined. The fluctuation of LHV and ash contents of the co-incinerated waste feedstock (CIWF) and source strengths of HCl and SO 2 in the flue gas were explored via simulated calculation based on proximate and ultimate analysis data of CW and MSW available in scientific literature. Then, the incineration residues from a MSWI plant in Wuhan city during and after COVID-19 outbreak, i.e., with and without co-incineration, were collected and characterized. The policies and experience of CW management in Wuhan city have been summarized in previous studies [6, 12, 13] . Before the COVID-19 outbreak, CW had been predominantly treated in centralized disinfection facilities and CW incinerators which can handle steady-state conditions [6, 14] . However, during COVID-19 outbreak, co-incineration had to be performed to manage the dramatic increase in CW. Therefore, the contents of major elements and heavy metals in the incineration residues were determined and compared. Furthermore, the effects of CW co-incineration on the fate of major elements and heavy metals as well as potential boiler corrosion were examined by statistical analysis. The findings of this study provide further insights into the risk assessment of CW treated in MSWI, thereby serving as a guide to safe application. In total, 62 and 31 sets of physical compositions of MSW (Table S1 ) and CW (Table S2) were obtained, respectively, with 62×31=1922 permutations of co-incineration mode between MSW and CW with each co-incineration ratio. Tables S3 and S4 show the proximate and ultimate analysis data and higher heating value data of typical fractions for MSW and CW, respectively, of which, the mean values were used for prediction calculations. For assessing the effects of CW co-incineration in MSW incinerator, the LHV and ash contents of CIWF and the concentrations of HCl and SO 2 in flue gas from co-incineration were predicted as shown in Eqs. (1) - (13) . First, the ultimate analysis results were transformed from dry basis to wet basis, and the elemental compositions of CIWF with different CW co-incineration ratios were calculated as follows: (1) Subsequently, the source strengths of acid gas in flue gas from CIWF incineration were deduced, as shown in Eqs. (3) - (12) . Flue gas is mainly composed of N 2 , CO 2 , H 2 O, O 2 , SO 2 , and HCl [16] . The excess air ratio was set as 2.1, which is often used for full-scale incinerators. (3) J o u r n a l P r e -p r o o f where V(A 0 ) is the theoretical air demand for incineration of 1 kg of CIWF (Nm 3 /kg CIWF); The entire Cl in the feedstock was considered to be discharged into flue gas as HCl. The d-factor was adopted to quantify the uncertainty of the calculation results. In general, a higher d-factor for a parameter indicates that it has greater influence on the results [20, 21] . All the physical composition values of plastic, paper, textile, and tissue in CW as parameters were assumed to fluctuate by ±10%, and the changes in the predicted results were observed with CW co-incineration ratio of 20%. J o u r n a l P r e -p r o o f (15) where d X ̅̅̅ is the sum of the difference between the estimated result after parameter fluctuation X 2m and that before parameter fluctuation X 1m , σ X is the standard deviation of the estimated results before fluctuation, and k is the number of data groups (co-incineration mode; k = 1922). During the COVID-19 pandemic between March and May 2020, co-incineration of CW was performed in a MSWI plant in Wuhan city. The co-incinerated CW included those from designated hospitals, shelter hospital, and isolation locations. The general information and material flow are summarized in Tables S5 and S6 . To investigate the effect of CW co-incineration ratios on MSWI, 40 air pollution control (APC) residues and 32 bottom ash (BA) samples with different CW input amounts, named as CWG, were collected. For comparison, 10 APC residues and 10 BA samples from the same MSWI without CW co-incineration, named as NCWG, were also collected (June -July 2020). The specific co-incineration amounts of CW per day during sampling are tabulated in Table S6 . It can be noted from the table that the co-incineration ratios of CW were <10 wt% of the incinerated MSW. All the incineration residues samples were dried at 105 C for 24 h. The relative contents of major elements in the incineration residues were determined by X-ray fluorescence spectrometer (XRF-1800, Shimadzu, Japan). The contents of heavy metals in the APC residues were measured by inductively coupled plasma optical emission spectroscopy (ICP-OES) (5100-OES, Agilent, USA) after acid digestion according to EPA Method 3050B [22] . All the chemicals and reagents utilized in this study were purchased from Sinopharm Chemical Reagent Co., Ltd. (China), including concentrated HCl, HNO 3 , HF, HClO 4 , etc., and all the solutions employed for the experiments were prepared using Milli-Q water. Descriptive statistics and correlation analysis were performed to evaluate the calculated and The estimated LHV and ash contents of CIWF under various CW co-incineration ratios (0%, 5%, 10%, 15%, and 20%) are summarized in Figs. 1A, 1B, and S1. LHV(Dulong) wet and LHV(literature) wet were 8691 ± 1563 kJ/kg (Fig. 1A) and 8233 ± 1558 kJ/kg (Fig. 1B) , respectively, when the CW co-incineration ratio was 0%. Similar LHV results were obtained using two different methods, and the LHV of CIWF showed an upward trend with the increasing CW co-incineration ratio. Moreover, the ash contents of CIWF significantly increased from 11% ± 7% to 15% ± 6% as the CW co-incineration ratio was increased from 0% to 20% (Fig. S1) , which was mainly caused by the inorganic components (glass and metals) in CW (Table S4 ). The concentrations of HCl and SO 2 in flue gas under different CW co-incineration ratios are shown in Fig. 1C and 1D . The HCl concentrations were 825 ± 78, 1536 ± 438, 2190 ± 804, 2795 ± 1119, and 3359 ± 1392 mg/Nm 3 when the CW co-incineration ratios were 0%, 5%, 10%, 15%, and 20%, respectively (Fig. 1C) , whereas the corresponding SO 2 concentrations were 1000 ± 188, 939 ± 160, 882 ± 142, 829 ± 131, and 780 ± 126 mg/Nm 3 , respectively (Fig. 1D) . Thus, a significant increase (P < 0.001) in HCl concentration and decline (P < 0.001) in SO 2 concentration were observed with the increase in CW amounts. These results are in agreement with the reported actual concentrations of HCl and SO 2 in MSWI flue gas from boiler (about 500 -2000 and 200 -1000 mg/Nm 3 , respectively) [8, 19, 23] . It should be noted that the concentration of HCl reached or exceeded the maximum of this range in MSWI when the CW co-incineration ratio was >10%. These findings confirmed that the ratio of CW treated in MSWI should be limited. The results of uncertainty analysis of the impact factors, contents of plastic, paper, textile, and J o u r n a l P r e -p r o o f tissue in CW are presented in Table 1 . The variation in plastic proportion showed significant effects on the estimated LHV(Dulong) wet and LHV(literature) wet of CIWF, as well as the source strengths of HCl in flue gas, with d-factors of 0.13, 0.13, and 0.14, respectively. Paper and textile exhibited similar influences on the estimated results, whereas tissue proportion exerted minimum influence. The use of plastic products has sharply increased for achieving protection from COVID-19 infection, which has resulted in subsequent massive generation of plastic waste [24] [25] [26] . Plastic waste with high organic carbon content, which is a statistically significant predictor of LHV [27] , can increase the average LHV of feedstock in co-incineration plants (Fig. 1A, Table 1 ), thus influencing the temperature of the furnace. Furthermore, the Cl content in PVC, one of the main compounds in plastic waste (e.g., syringes, vinyl gloves) [24, 28] can enhance HCl emission (Fig. 1C) and formation of chlorinated aromatic compounds [29] . Therefore, the exhaust gas emissions from stack must be monitored when CW is co-incinerated in MSWI, and if an increasing trend is detected, then J o u r n a l P r e -p r o o f the operation parameters of the APC system should be adjusted to ensure compliance with the emission limits, especially the semi-dry scrubber for absorbing acid gas and activated carbon injection for removal of heavy metals and chlorinated aromatic compounds. Prediction calculation using material flow model helps to investigate the influence of CW Incineration of solid waste not only emits gases (SO 2 , HCl, etc.), but also generates solid residues such as APC residues and BA. To investigate the changes in major elements in the incineration residues in response to the introduction of CW in MSWI, elemental analysis of the incineration residues was conducted by using XRF. The top 6 elements were used as factors and subjected to principal component analysis (Fig. 2) . Two principal components explained 94.9% and 93.9% of the variability in the datasets of APC residues ( Fig. 2A) and BA (Fig. 2B) , respectively. The most common elements in APC residues were C, Ca, Cl, Na, K, and S, whereas those in BA were Ca, C, Si, Cl, Al, and Fe, which are in agreement with those reported in previous studies [30, 31] . A good distinction in the element contents in the APC residues was observed between NCWG and CWG, which was governed by specific major contributors of the Dim2 scores, including the contents of C, Ca, Cl, Na, and K (Student's t test, P < 0.01). On the contrary, no statistically significant J o u r n a l P r e -p r o o f difference in the element contents in BA was detected. The differences in the C and Ca contents in the APC residues can be ascribed to the variance in APC operational condition, instead of feedstock [31] , whereas the differences in other elements in the APC residues can be attributed to the input of CW components. Figure 3 summarizes the contents of major elements in the APC residues (Fig. 3A) and BA ( Fig. 3B ) with varying CW co-incineration amounts. In the APC residues, with the increasing CW co-incineration amount from 0.0 to 87.0 t/day (<10 wt% of MSW incinerated, around 1000 t/day), the contents of Na, K, Si, P, and Ti increased; those of Ca and C decreased; and those of Cl, S, Mg, Al, and Fe showed negligible variations. Besides, the Na content (9.0% ± 1.6%) in CWG exceeded that reported in previous studies (0.6% -8.4%) [30, 31] . When compared with the APC residues, the fluctuation in the major element contents in BA with varying CW co-incineration amounts was insignificant (Fig. 3B ). It is generally accepted that elements in waste are distributed in flue gas during MSWI by two potential processes: (i) elements are entrained by particles and (ii) elements evaporate in the furnace and exist in gas phase or condense and are adsorbed on the surface of particles [17, [32] [33] [34] . The results of correlation matrix and hierarchical clustering determined in the present study for the variation tendency of element richness in the APC residues ( Fig. 4) are consistent with those previously reported [34] . It has been indicated that Na, K, P, Ti, Si, and Mg in input waste are non-volatile and more likely to be entrained into flue gas with particles and then captured into the APC residues. The elements Br, Pb, Zn, and Cu are mainly transformed by evaporation, while Mn and Cr represent the least volatile elements [35] . Based on the above-mentioned data, although addition of CW in MSWI had an influence on the major constituents of the APC residues (Fig. 3A) , the negligible alteration with regard to the distribution behavior of elements when the CW amounts treated in MSWI were <10 wt% was J o u r n a l P r e -p r o o f ascertained. The contents of heavy metals in the APC residues analyzed by ICP-OES are shown in Fig. 5 . The Ba, Cr, Mn, and Ni contents in CWG were significantly higher when CW was treated in MSWI Correlation matrix (Fig. S3) indicated that the distributions of heavy metals occurred via two processes, which was consistent with the results presented in Fig. 4 . Ba, Cr, Mn, and Ni were transferred to flue gas mainly by entrainment from particulate matter [17] , while As, Cd, Cu, Zn, and Pb were mostly transferred via evaporation [32] . The increase in Ba, Cr, Mn, and Ni (mainly derived from alloys) contents in the APC residues of CWG could possibly be attributed to the widespread use of metallic instruments, such as needles and grippers [36] , during COVID-19 pandemic. In previous studies, the contents of Ba, Cr, Mn, and Ni in the APC residues from MSWI have been reported to be 34 -14,000, 72 -570, 200 -1700, and 19 -710 mg/kg, respectively [31, 34] ; thus, the heavy metals contents in the APC residues of CWG determined in the present study are significantly lower than the upper limits described in the literature. In addition, as Ba, Cr, Mn, and Ni are difficult to leach out [37] , the increase in the contents of these heavy metals had less effect on the J o u r n a l P r e -p r o o f leaching toxicity risk of the APC residues. It must be noted that CW co-incineration ratios < 10 wt% had only negligible impact on BA as additives for construction materials and disposal of APC residues in security landfill. In general, Na and K in feedstock are released as alkali metal chlorides, and approximately 46% of Cl has been reported to be NaCl and KCl, while the rest occur as CaCl 2 and Friedel's salt in the APC residues sampled from the bag filter, with the injection of Ca(OH) 2 or CaO for acid gas removal [38] . Figure 6 depicts the positive relationship between the molar amounts of Cl and sum of those of K and Na in the APC residues. Owing to the strong affinity of Cl for Na and K, the relatively high contents of Cl in CW might accelerate the generation of low-melting alkali metal chlorides (NaCl and KCl) and subsequent transfer into flue gas during co-incineration [39] . NaCl and KCl are prone to get deposited on the surface of the boiler, while HCl in gas phase might induce severe slagging and corrosion problems [40, 41] . Under oxidizing conditions, HCl is oxidized at the deposit/gas interface, releasing Cl 2 [42] . Alkali metal chlorides lower the melting temperature of deposits [43] and react with the protective oxide layer (Cr, Fe) 2 O 3 to form alkali chromate and ferrate and simultaneously release Cl 2 . Subsequently, the alloy materials beneath the protective oxide layer are exposed to chlorine corrosion [44] . Therefore, co-incineration of CW in MSWI may cause boiler corrosion, further affecting the durability and service time of the boiler [41] . This study evaluated the effects of CW co-incineration in MSWI plant during COVID-19 pandemic via simulated calculation and field sampling. A material flow model calculation was employed to assess the effects of CW co-incineration on feedstocks properties and acid gas emissions. The prediction results showed that the ash contents and LHV of CIWF as well as the concentration of HCl in flue gas were significantly increased when the CW co-incineration ratio J o u r n a l P r e -p r o o f was increased from 0 wt% to 20 wt%. Analyses of the element contents in the APC residues and BA from MSWI with and without CW co-incineration (CWG and NCWG, respectively) revealed the following: (i) the major element contents in the APC residues significantly changed, whereas those in BA showed negligible variation in CWG, when compared with those in NCWG, and the transfer behavior of the elements in the incinerator remained similar and consisted with that reported in the literature; (ii) the contents of non-volatile heavy metals, such as Ba, Cr, Mn, and Ni, significantly increased in CWG, whereas they were still within the reported ranges in NCWG; and (iii) the increased contents of alkali metals and HCl in flue gas might exacerbate corrosion of boiler surface. These findings provide a better understanding of the impacts of CW on MSWI and can guide future applications of co-incineration during and post pandemic. SARS-CoV-2 spillover events World Health Organization, WHO Coronavirus Disease (COVID-19) Dashboard, The World Health Organization COVID-19 pandemic repercussions on the use and management of plastics Quantitative evaluation of infectious health care wastes from numbers of confirmed, suspected and out-patients during COVID-19 pandemic: A case study of Wuhan, Waste Manage COVID-19's unsustainable waste management Emergency response to the explosive growth of health care wastes during COVID-19 pandemic in Wuhan Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Best available techniques (BAT) reference document for waste incineration Increased plastic pollution due to COVID-19 pandemic: Challenges and recommendations COVID-19 discarded disposable gloves as a source and a vector of pollutants in the environment The escalating biomedical waste management to control the environmental transmission of COVID-19 pandemic: A perspective from two south asian countries Reverse logistics network design for effective management of medical waste in epidemic outbreaks: Insights from the coronavirus disease 2019 (COVID-19) outbreak in wuhan (China) Disinfection technology of hospital wastes and wastewater: Suggestions for disinfection strategy during coronavirus Disease 2019 (COVID-19) pandemic in China Technological review on thermochemical conversion of COVID-19-related medical wastes, Resour A simple method for predicting the lower heating value of municipal solid waste in China based on wet physical composition, Waste Manage Chlorophenols in municipal solid waste incineration: A review Factors determining the element behavior in municipal solid waste incinerators. 1. Field studies Migration and transformation of sulfur in the municipal sewage sludge during disposal in cement kiln Estimating source strengths of HCl and SO 2 emissions in the flue gas from waste incineration Estimating physical composition of municipal solid waste in China by applying artificial neural network method Uncertainty analysis for the forecast of lake level fluctuations using ensembles of ANN and ANFIS models Acid digestion of sludges, solids and soils, USEPA 3050B Incineration treatment engineering technology of municipal solid waste Minimising the present and future plastic waste, energy and environmental footprints related to COVID-19 The impact of the COVID-19 pandemic on waste-to-energy and waste-to-material industry in China Valorization of disposable COVID-19 mask through the thermo-chemical process Revisiting the elemental composition and the calorific value of the organic fraction of municipal solid wastes, Waste Manage Challenges, opportunities, and innovations for effective solid waste management during and post COVID-19 pandemic Emissions of polycyclic aromatic hydrocarbons, polychlorinated dibenzo-p-dioxins, and dibenzofurans from incineration of nanomaterials Treatment and use of air pollution control residues from MSW incineration: An overview, Waste Manage Thermal treatment of solid residues from WtE units: A review, Waste Manage Factors determining the element behavior in municipal solid waste incinerators. 2. Laboratory experiments Fate of heavy metals during municipal solid waste incineration in Shanghai Metal distribution in incineration residues of municipal solid waste (MSW) in Japan Energy from municipal solid waste: A comparison with coal combustion technology Characterisation and management of ash produced in the hospital waste incinerator of Athens Chemical characteristics and risk assessment of typical municipal solid waste incineration (MSWI) fly ash in China Chloride chemical form in various types of fly ash Review on the current status of the co-combustion technology of organic solid waste (OSW) and coal in China In-situ measurement of temperature and alkali metal concentration in municipal solid waste incinerators using flame emission spectroscopy, Waste Manage Slagging characteristics caused by alkali and alkaline earth metals during municipal solid waste and sewage sludge co-incineration The fate of chlorine during MSW incineration: Vaporization, transformation, deposition, corrosion and remedies Ash-related issues during biomass combustion: Alkali-induced slagging, silicate melt-induced slagging (ash fusion), agglomeration, corrosion, ash utilization, and related countermeasures KCl-induced corrosion of the FeCrAl alloy Kanthal® AF at 600° C and the effect of H 2 O We acknowledge the support from the National Key R&D Program of China (2020YFC1910100).