key: cord-0867684-10wx1n6a authors: Olbrich, Laura; Castelletti, Noemi; Schälte, Yannik; Garí, Mercè; Pütz, Peter; Bakuli, Abhishek; Pritsch, Michael; Kroidl, Inge; Saathoff, Elmar; Guggenbuehl Noller, Jessica Michelle; Fingerle, Volker; Le Gleut, Ronan; Gilberg, Leonard; Brand, Isabel; Falk, Philine; Markgraf, Alisa; Deák, Flora; Riess, Friedrich; Diefenbach, Max; Eser, Tabea; Weinauer, Franz; Martin, Silke; Quenzel, Ernst-Markus; Becker, Marc; Durner, Jürgen; Girl, Philipp; Müller, Katharina; Radon, Katja; Fuchs, Christiane; Wölfel, Roman; Hasenauer, Jan; Hoelscher, Michael; Wieser, Andreas title: Head-to-head evaluation of seven different seroassays including direct viral neutralisation in a representative cohort for SARS-CoV-2 date: 2021-10-08 journal: J Gen Virol DOI: 10.1099/jgv.0.001653 sha: 7a13d441742d9226a7360e43e80b32d882dabd82 doc_id: 867684 cord_uid: 10wx1n6a A number of seroassays are available for SARS-CoV-2 testing; yet, head-to-head evaluations of different testing principles are limited, especially using raw values rather than categorical data. In addition, identifying correlates of protection is of utmost importance, and comparisons of available testing systems with functional assays, such as direct viral neutralisation, are needed.We analysed 6658 samples consisting of true-positives (n=193), true-negatives (n=1091), and specimens of unknown status (n=5374). For primary testing, we used Euroimmun-Anti-SARS-CoV-2-ELISA-IgA/IgG and Roche-Elecsys-Anti-SARS-CoV-2. Subsequently virus-neutralisation, GeneScriptcPass, VIRAMED-SARS-CoV-2-ViraChip, and Mikrogen-recomLine-SARS-CoV-2-IgG were applied for confirmatory testing. Statistical modelling generated optimised assay cut-off thresholds. Sensitivity of Euroimmun-anti-S1-IgA was 64.8%, specificity 93.3% (manufacturer’s cut-off); for Euroimmun-anti-S1-IgG, sensitivity was 77.2/79.8% (manufacturer’s/optimised cut-offs), specificity 98.0/97.8%; Roche-anti-N sensitivity was 85.5/88.6%, specificity 99.8/99.7%. In true-positives, mean and median Euroimmun-anti-S1-IgA and -IgG titres decreased 30/90 days after RT-PCR-positivity, Roche-anti-N titres decreased significantly later. Virus-neutralisation was 80.6% sensitive, 100.0% specific (≥1:5 dilution). Neutralisation surrogate tests (GeneScriptcPass, Mikrogen-recomLine-RBD) were >94.9% sensitive and >98.1% specific. Optimised cut-offs improved test performances of several tests. Confirmatory testing with virus-neutralisation might be complemented with GeneScriptcPass(TM) or recomLine-RBD for certain applications. Head-to-head comparisons given here aim to contribute to the refinement of testing strategies for individual and public health use. In December 2019, a cluster of atypical pneumonia of unknown origin was described in the region of Wuhan, Hubei province, China. Subsequently, a previously unknown coronavirus was identified as the causative agent: SARS-CoV-2 (Severe Acute Respiratory Syndrome Coronavirus 2) [1] . As the virus spread rapidly across the globe, the Corona Virus Disease 2019 (COVID- 19) was declared a pandemic on 12 March 2020. Direct detection of viral nucleic acids or the virus itself in bodily fluids is considered the reference standard for diagnosis of acute infection. It is primarily performed using nasopharyngeal swabs or other respiratory samples [2] . Additionally, serodiagnostics are valuable to identify past infections, asymptomatic or symptomatic, and to elucidate transmission dynamics within populations. Both are highly relevant to inform evidence-based political decision making [3, 4] . Several serological test systems have been introduced since the beginning of the SARS-CoV-2 pandemic [5] . Most target one of two specific viral structures: parts of the trimeric CoV spike (S1-2) complex, or the nucleocapsid (N) protein [6] . While the receptor binding domain (RBD) of S1 binds to the angiotensin-converting enzyme 2 (ACE2) as a receptor, the N-protein is involved in viral assembly and replication [7] . Head-to-head comparisons evaluating qualitative assay performances have been described, yet mostly with limited additional workup and sample characterisation [8] [9] [10] [11] . Some authors have proposed adapted cut-off thresholds to increase assay performance, depending on application and local epidemiology [4, 12] . Here, we present a head-to-head cross-comparison of seven independent tests. We screened with Euroimmun Anti-S1-SARS-CoV-2-ELISA-IgA and -IgG and Elecsys Anti-SARS-CoV-2 Roche N pan−Ig and confirmed with direct viral neutralisation, GeneScriptcPass, Mikrogen-recomLine-RBD IgG line immunoassay, and VIRAMED-SARS-CoV-2-ViraChip microarray. The tests were conducted on a total of 6658 samples from (i.) RT-PCR positive individuals (truepositives), (ii.) blood donors from the pre-COVID-19 era (true-negatives), and (iii.) subjects with unknown disease status from a representative population cohort in Munich (KoCo19; unknown serostatus) [13] . We were able to generate reliable performance estimates for both primary and confirmatory tests by using true-positive and true-negative individuals and hereby generate optimised cut-offs. Samples are derived from the representative COVID-19 Cohort Munich (KoCo19), a prospective sero-incidence study initiated in Munich, Germany, in April 2020 [13, 14] . For this study, we tested 6658 samples, including a set of SARS-CoV-2 RT-PCR positives ('true-positives' , n=193), individuals from historical cohorts, blood donors without any indication of SARS-CoV-2 infection ('true-negatives' , n=1091), and specimen of unknown status (n=5374); details on the cohort characteristics, including collection time points, can be found in the appendix (p.1; Table S1 , available in the online version of this article). The study was approved by the Ethics Committee of the Faculty of Medicine at LMU Munich (20-275 V), the protocol is available online ( www. koco19. de) [13] . Informed consent was obtained prior to any study investigations where applicable. The study is registered in the German Clinical Trials Register (DRKS00021698;https://www. drks. de/ drks_ web/ navigate. do? navigationId= trial. HTML& TRIAL_ ID= DRKS00021698). All described analyses were performed using EDTAplasma samples (appendix pp.1 for further details on assays performed, and Table S3 for details on platforms and units applied). Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgA/ IgG (called EI-S1-IgG, EI-S1-IgA; Euroimmun, Lübeck, Germany) test kits were used according to the manufacturer's instructions. Measurement values were obtained using the quotient of the optical density measurement provided by the manufacturer's software. We evaluated Elecsys Anti-SARS-CoV-2 Roche anti-N pan-Ig (hereafter called Ro-N-Ig; Roche, Mannheim, Germany) in accordance with the manufacturer's guidelines. Values reported are the Cut-Off-Index (COI) of the individual samples. Operative replicates of the same samples were performed to assess reliability of primary assay performance. We present an evaluation of seven serological SARS-CoV-2 tests used as screening or confirmation tests in a large, well-defined cohort including true-positive and true-negative individuals, as well as subjects with unknown SARS-CoV-2 status. A total of 6658 individual samples were derived from the Representative COVID-19 Cohort Munich (KoCo19), a prospective seroincidence study initiated in Munich, Germany, in a low-prevalence setting of a large German city, not considered a specific 'hot-spot' at time of sampling. This comprehensive collection allowed us to correlate the different tests to identify concordance as well as discordance for the individual samples. This also enabled the evaluation of confirmatory test systems, like direct virus-neutralisation or the recently FDA-approved GeneScriptcPassTM, compared to different serological tests, including receptor binding domain (RBD)-based assays. In addition, we assessed their overall performances in KoCo19, and adjusted cutoffs; furthermore, we analysed the seroconversion rate in patients with a history of positive RT-PCR. For confirmatory testing, we conducted micro-virus neutralisation assays (NT) as described previously [15] , with the exception that confluent cells were incubated instead of adding cells following neutralisation reaction (appendix pp.1). We classified samples with a titre <1:5 as 'NT-negative' and samples with a titre ≥1:5 as 'NT-positive' . The dilution steps indicated are <5, 5, 10, 20, 40 and >80. SARS-CoV-2 surrogate virus neutralisation test (GS-cPass; GenScript, Piscataway, New Jersey, USA) was used to measure binding inhibition, according to the manufacturer's instructions. The inhibition was calculated in percentages, ranging from −30 to 100. For SARS-CoV-2 ViraChip microarray (VIRAMED Biotech AG, Planegg, Germany; hereafter named VC-N-IgA/IgM/ IgG; VC-S1-IgA/IgM/IgG; VC-S2-IgA/IgM/IgG) execution followed the manufacturer's instructions. We obtained measurement values by the automated ELISA-processor in arbitrary units. We conducted the recomLine SARS-CoV-2 IgG line immunoassay (MG-S1, MG-N, MG-RBD; Mikrogen, Neuried, Germany) as outlined by the manufacturer. Values below the cut-off of 1 were categorised as 'negative' without quantitative information. Prior to analysis, we cleaned and locked the data. For the analyses and visualisation, we used the software R, version 4.0.2. Only one sample per subject was included in the statistical analyses; in the case of individuals with multiple blood samples, we only considered the sample with the most complete dataset. For multiple measurements with complete datasets, we only included the first measurement; for operational replicates we used the latest one. We subsequently carried out sensitivity and specificity analyses for true-negative and true-positive samples over all the tests performed. We report square roots R of coefficients of determination for association among continuous variables. For paired sample comparisons, we applied Wilcoxon-sign-rank tests, whereas for multiple group comparisons we applied Kruskal-Wallis tests, followed by post-hoc Dunn tests using the Benjamini-Yekutieli adjustment for pairwise comparisons [16] . Using true-positives and true-negatives, we determined optimised cut-off thresholds and their confidence intervals by a nonparametric bootstrap. In a similar way, we trained random forest and support vector machine classifiers. We calculated estimates for sensitivities, specificities, and overall prediction accuracies for all considered cut-off values and classifiers. This calculation was done on out-of-sample observations to avoid overfitting and thus overoptimistic performance measures. Details on the algorithms are outlined in the appendix (pp.3). Data are accessible subject to data protection regulations upon reasonable request to the corresponding author. To facilitate reproducibility and reuse, the code used to perform the analyses and generate the figures was made available on GitHub (https:// github. com/ koco19/ lab_ epi) and has been uploaded to ZENODO (is https:// doi. org/ 10. 5281/ zenodo. 4699432) for long-term storage. We assessed SARS-CoV-2 antibodies in a total of 6658 independent samples using Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgA (henceforth called EI-S1-IgA; n=6657), Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgG (EI-S1-IgG; n=6658), and Elecsys Anti-SARS-CoV-2 Roche anti-N pan-Ig (Ro-N-Ig; n=6636) (details on cohort and sample characteristics are outlined in Fig. S1 , Table S1 ). Sensitivity and specificity estimates of both primary and confirmatory tests of manufacturer and optimised cut-offs are shown in Tables 1 and S2 features an overview of all tests performed. Sensitivity and specificity of EI-S1-IgA were 64.8 and 93.3% when applying the manufacturer's cut-off. Optimising the cutoff through statistical learning (see Methods) did not improve EI-S1-IgA performance (sensitivity 64.8%, specificity 92.6%). For EI-S1-IgG, the sensitivity of 77.2 % (manufacturer's cutoff) was increased to 79.8% (optimised cut-off), while the specificity remained similar at 98.0/97.8 % (manufacturer's/ optimised cut-off; Table 1 ). The distribution of results for the EI-assays is depicted in Fig. 1 . Raw values for EI-S1-IgA show a slightly asymmetric but unimodal distribution for the overall population, while EI-S1-IgG raw values present with a second clearly distinct positive population. EI-S1-IgA classified 65% of the true-positives correctly as positive and 7% of the true-negatives incorrectly as positive, while EI-S1-IgG classified 80% of the true-positives correctly and 2% of the true-negatives incorrectly. A total of 61% of the true-positives were identified correctly by both tests unanimously. The sensitivity of Ro-N-Ig with the manufacturer's cut-off was 85.5%, and was increased to 88.6% by applying an optimised cut-off, similarly to EI-S1-IgG. Specificity was similar with both cut-offs at 99.8/99.7 % (manufacturer's/optimised cut-off; Table 1 ). Ro-N-Ig raw values (Cut-off index, COI) demonstrate a narrow distribution with the bulk of values in the range COI 0.1 and below, whereas a clearly separated second population above COI 10 was observed. For EI-S1-IgG and Ro-N-Ig, the cut-offs separate the subpopulations more reliably than for EI-S1-IgA (Fig. 1) . For evaluation of primary test concordance, we excluded EI-S1-IgA due to inferior performance in sensitivity and specificity. The concordance between EI-S1-IgG and Ro-N-Ig was 98.5% (6538/6636). From the whole sample set, 4.0% (264/6636) were unanimously classified as positive while 94.5% (6274/6636) were classified as negative, of these 88.1% (5846/6635) tested negative in all three tests (being 93.2% (5846/6274) of those negative in Ro-N-Ig+EI-S1-IgG). The remaining 1.5% of samples (98/6636) were classified discordantly. Of these, 56.1% (55/98) were rated as positive by El-S1-IgG and as negative by Ro-N-Ig (Fig. 2a) , while the remaining 43.9% (43/98) were rated as negative by EI-S1-IgG and as positive by Ro-N-Ig. We investigated seropositivity following positive RT-PCR using one measurement per subject (Fig. 3) . EI-S1-IgA titres were found to decline >30 days (P=0.01), with only 65% being positive at the last interval, while EI-S1-IgG remained stable over the time period (P=0.85). In contrast, antibody levels measured with Ro-N-Ig increased over time (P<0.001). We subjected a sample subset (n=362; composition see Fig. S1) to confirmatory testing; the overall confirmatory test performance is presented in Fig. 4 and Table 1 . The sensitivity of direct neutralisation titres (NT; 1:5 dilution) was 80.6%, Table 1 . Manufacturer's and optimised cut-offs, sensitivity, specificity and accuracy Evaluation of diagnostic accuracy of primary tests was conducted with samples from true-positives (n=193) and true-negatives (n=1073); subsequently, optimised cut-offs were applied to the KoCo19-cohort samples (see Methods). †The random forest and the support vector machine combine all three primary tests, the accuracy measures thus do not relate to specific cut-offs. Fig. 1 . Performance of primary tests. Results of primary tests for true-negatives (blue), true-positives (orange), and individuals with unknown SARS-CoV-2 status (grey). Absolute number of subjects (count/y-axis) and distribution of raw values (x-axis) measured for EI-S1-IgA (left), EI-S1-IgG (centre), and Ro-N-Ig (right). Dotted lines mark the manufacturer's cut-off value (between indeterminate and positive for EI, and between negative and positive in Ro). Dashed lines mark the optimised cut-off value as determined in this study (overlapping with the dotted line for EI-S1-IgA). Orange and blue solid lines represent the percentage of test results for true-positives and true-negatives above (blue) or below (orange) the value on the x-axes, respectively. Orange and blue numbers give the percentages of true-positives and true-negatives that were correctly detected by the test (within brackets: manufacturers' cut-offs; without brackets: optimised cut-offs). 96.3% for GS-cPass, and 94.9 % for MG-RBD. All three tests had a specificity close to 100 % (Fig. 4) . Adjustments of the cut-off in these three systems did not improve the performance (shown in parentheses in the Figures). NT-titres in our cohort were low -mostly 1:5 -and only few subjects had high NT of 1 : 80 or above (Fig. 4a) . For the VC-array, sensitivities of both VC-S1-IgG and VC-N-IgG were improved markedly by optimising cut-offs, with gains of >30% (VC-N-IgG 39.8/93.5%; VC-S1-IgG 65.7/95.4%; see Table 1 , Fig. 4c ). Performance of VC-S2-IgA and VC-S2-IgM are presented for reference in Fig. S5 . The categorical endpoints of NT and the continuous results of GS-cPass were positively related (R2=0.74), agreement with the ground truth was frequent (80%). However, more than 17% of true-positive samples were negative in NT (n=21, Fig. 5a ). Correlation between NT and MG-RBD was similar to GS-cPass (n=272, Fig. 5b ). However, separation between the negative and positive population was better in MG-RBD than with GS-cPass, especially in those true-positives with low direct neutralisation capacity (NT <5). Association between GS-cPass and MG-RBD was good (n=272, Fig. 5c ), discordant results were observed in 8% of true-positives. The distribution presented as increasingly narrower in higher titre ranges. To examine pre-test probability of assays following positive initial testing, the measurement values of all primary and confirmatory tests were correlated (Figs 6, S7-9). Overall, Counts n (n refer to the number of observations above/below manufacturer's (optimised) cut-off for each of the temporal groups). Pairwise differences are considered only after adjusting for multiple testing and can be found in Table S4 . Mean values (mv) and median values (med) are given for each group. we observed high correlations, particularly for GS-cPass and MG-RBD with EI-S1-IgG, and MG-N with Ro-N-Ig (Fig. 6) . The categorical concordance for GS-cPass, MG-RBD, and MG-N with both Ro-N-Ig and EI-S1-IgG was similar (94 % or above), while the concordance of NT with both primary tests was lower (80%; Fig. 6 ). Concordances were improved by applying the optimised cut-offs, especially for VC-S1-IgG and VC-S2-IgG (Fig. S7 ). We performed head-to-head comparisons of seven seroassays for SARS-CoV-2 and derived optimised cut-offs for several tests in a well-defined cohort with a total of 6658 samples [13, 14] . Although several reports have emerged that investigate the seroresponse to SARS-CoV-2 [4, 7, [17] [18] [19] [20] [21] [22] [23] [24] [25] , only few feature direct head-to-head comparisons of many different assays in one set of samples [9, 11, 12, 26] . Studies have often used widely different patient populations, hampering direct comparisons of testing systems. In contrast, our study provides data generated from a representative cohort of the inhabitants of Munich, and not selected patient cohorts [13] , allowing a more generalisable interpretation of results presented. When choosing the primary tests, we considered four main characteristics (i) availability in large quantities, (ii) enabled for at least semi-automated workup, (iii) acceptable pricing and iv) licenced for the use in europe. These criteria excluded tests such as VC-Array as they were too expensive (>20 EUR/test). GS-cPass was excluded, as at the time of the study it was not licensed for use yet, although this has changed by now, however still lacking automation. The EI-S1-IgG and IgA as well as Ro-N-Ig tests fulfilled all criteria and were thus applied. Several studies have shown a relationship between disease severity and both antibody kinetics [6, 18, 20, 27, 28] and neutralisation capacity [17, [29] [30] [31] . Our data is derived from a population-and not primarily a patient based approach, thus the interpretation of the data is mainly for epidemiological use. Here, our data suggest that Ro-N-Ig performs more reliably than EI-S1-IgA and EI-S1-IgG, especially in low prevalence settings due to the lack of specificity in EI-S1-IgA and -IgG, similarly to previously published reports [4] . We would not recommend using serology to diagnose acute infections, as RT-PCR is positive during the acute phase of the infection and serology will become positive only later. Nevertheless, singling out subjects who require only one booster vaccination to save vaccination doses, or to identify possible re-infections might be important questions in direct patient care currently, besides epidemiological questions such as the assessment of possible herd immunity levels in the population. In addition to the previously mentioned primary screening tests, we assessed confirmatory test performances using a subset of true-positive and true-negative samples, comparing assays targeting the highly-specific receptor binding domain (NT, GS-cPass, MG-RBD), which are considered direct or surrogate markers for viral neutralisation [32] . Our truepositive sample set was mainly derived from subjects with few to no symptoms, with often a rather low neutralising activity, allowing an in-depth cross-comparison of direct viral neutralisation (NT) with surrogate neutralisation markers (GS-cPass, MG-RBD) in oligo-or asymptomatic individuals. While NT is a direct representation of viral neutralisation, GS-cPass assesses the antibody-mediated inhibition of ACE2-interaction with SARS-CoV-2-S1-RBD and is therefore a cell-free surrogate neutralisation marker [33] . The cell-culture free tests performed particularly well with sensitivities of 96.3% for GS-cPass and 94.9% for MG-RBD, using the manufacturers' thresholds. In contrast, NT performed sub-optimally with a sensitivity of 80.6%. A compelling explanation would be a rapid decline in neutralising capacity, which has been reported previously and is in line with our observations [30, 34] . As NT requires a complex BSL-3-laboratory infrastructure, it currently represents a critical bottleneck, while the surrogate tests can be performed under BSL2 conditions. Furthermore, NT might miss a substantial part of cases especially with lower titres, thus GS-cPass or MG-RBD might be considered in these cases as they offer similar specificity. To investigate the potential yield from combining primary tests, we applied machine learning techniques (random forest and support vector machine, see Methods). However, these hardly improved the performance beyond what was achieved by Ro-N-Ig alone (Table 1) . Similarly to previously published studies, we could not demonstrate an added value of performing more than one confirmatory test [4] . By extending our true positive cohort using combinations of two or more positive confirmatory tests, we repeated the analysis, using the raw value of the primary tests as a decision criterion. Some performance improvement could be achieved by combining EI-S1-IgG with GS-cPass or MG-RBD in the materials with raw values between 0.8 and 2.55 (22% of the samples). In these cases, overall accuracy improved from 93-98% and 99%, respectively. For further details on these combinations, see supplemental material (Table S5 , Figs S10 and S11). Situation-specific cut-off optimization has been proposed as a tool to improve seroassay performances for SARS-CoV-2 [4, 12] . We therefore derived optimised cut-offs based on the true-positive and true-negative cohorts; hereby, we were able to improve sensitivity in EI-S1-IgG and Ro-N-Ig, while specificity remained similar. Meyer et al. proposed optimised thresholds for EI-S1-IgG, and suggested evaluating the manufacturer's cut-off before routine testing, highlighting the dilemma of securing both rule-in and rule-out properties to mitigate the risk of incorrect classification in a situation with highly-dynamic pre-test probabilities [4] . Whether these optimised cut-offs are generalisable remains uncertain: A seroprevalence study in Geneva compared both recommended and optimised cut-offs and did not observe any qualitative changes [25] . In our study, optimised cut-offs were similarly derived for confirmatory tests. Here, we could improve the sensitivity markedly for the VC-array with gains of >50% points for VC-N-IgG (39.8-94.4%) and close to 30% points for VC-S1-IgG (65.8-95.4%). Even though some changes in performance estimates seem minimal, they might translate into a higher number of correctly classified diagnoses when testing is performed on a large scale. This is especially pertinent in low-prevalence settings, as particularly a high specificity is crucial to achieve a high positive predictive value. It may also be preferable to have a more sensitive cut-off for a primary test and confirm the positives with a highly-specific secondary test system [14] . In a systematic review by Huang et al. in 2020, the median detection time across different antibodies against SARS-CoV-2 was 11 days, similar to SARS-CoV-1 [6] . We therefore additionally assessed the seropositivity stratified with the date of the first positive RT-PCR test. In our cohort of mostly oligosymptomatic true-positive subjects, 11.4% (22/193) were not detected in the primary serological tests, with a third of those being <30 days after positive RT-PCR. Overall, in our dataset of samples >30 days after positive RT-PCR, a modest 8.1% (13/160) remained negative. Late or lacking seroconversion has been described previously, mostly in oligo-or asymptomatic subjects [31, 35] , and authors have speculated about vastly varying proportions of subjects unable to mount an antibody response detectable by commonly used assays [20, 21, 36, 37] . Different studies have reported a rapid decline of antibody titres over time [20, 30, 34] . In our cohort, antibody levels measured with EI-S1-IgA declined early on, most pronouncedly within the first 30 days, resulting in 40% of the subjects being below the positive cut-off >30 days after RT-PCR positivity. In contrast, antibody levels detected with EI-S1-IgG remained stable and detectable over longer periods. Moreover, titres measured with Ro-N-Ig increased, with more than 80% of true-positive subjects being rated as positive >90 days. Studies published so far show ambiguous results, partly suggesting that overall, antibody responses to S might be more stable than responses to N [38] ; our results suggest that the observed differences are more attributed to the testing approach than the antigen itself. Our study has several limitations. The sample set is derived from a representative cohort in Munich, Germany. Despite being an ethnically diverse city, the results presented here might not be representative of other geographical regions. Additionally, it was not feasible to perform all confirmatory tests on all samples; a subset, namely those with positive results in at least one primary test as well as a known negative/ positive cohort, were tested using these systems. Finally, we did not have information on underlying health conditions of all subjects, e.g. conditions known to affect the quantity of polyclonal antibodies. In conclusion, our study provides a cross-comparison of seven different widely used serological assays for SARS-CoV-2 and proposes new cut-offs for several tests. This study can be used as a resource to enable the refinement of testing strategies for individual and public-health use. Our approach presented here used a well-defined sample set with true-positive as well as true-negative specimens. Subsequently, we extrapolated the established findings to samples derived from a population-based seroprevalence cohort and were therefore able to generate a robust head-to-head comparison for diagnostic performance estimates of several serological tests for SARS-CoV-2. Clinical features of patients infected with 2019 novel coronavirus in Wuhan A serological assay to detect SARS-CoV-2 seroconversion in humans Disease severity dictates SARS-CoV-2-specific neutralising antibody responses in COVID-19 Validation of a commercially available SARS-CoV-2 serological immunoassay SARS-CoV-2 diagnostic pipeline A systematic review of antibody mediated immunity to coronaviruses: kinetics, correlates of protection, and association with severity Serodiagnostics for severe acute respiratory syndromerelated coronavirus 2: a narrative review Performance of six SARS-CoV-2 immunoassays in comparison with microneutralisation Brief clinical evaluation of six high-throughput SARS-CoV-2 IgG antibody assays Quantification of SARS-CoV-2 antibodies with eight commercially available immunoassays Performance characteristics of five immunoassays for SARS-CoV-2: a head-to-head benchmark comparison Diagnostic performances and thresholds: the key to harmonization in serological SARS-CoV-2 assays Protocol of a population-based prospective COVID-19 cohort study Munich Prevalence and risk factors of infection in the representative COVID-19 cohort Munich Results of the first pilot external quality assessment (EQA) scheme for anti-SARS-CoV2-antibody testing The control of the false discovery rate in multiple testing under dependency Clinical evaluation of serological IgG antibody response on the Abbott Architect for established SARS-CoV-2 infection. Clinical microbiology and infection: the official publication of the Stringent thresholds for SARS-CoV-2 IgG assays result in underdetection of cases reporting loss of taste/smell Spread of SARS-CoV-2 in the Icelandic population Antibody responses to SARS-CoV-2 in patients with COVID-19 Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections Prevalence of SARS-CoV-2 in Spain (ENE-COVID): a nationwide, population-based seroepidemiological study. The Lancet Seroprevalence of COVID-19 virus infection in Guilan province Infection fatality rate of SARS-CoV-2 infection in a German community with a super-spreading event Seroprevalence of anti-SARS-CoV-2 IgG antibodies in Geneva, Switzerland (SEROCoV-POP): a population-based study Performance of abbott architect, ortho vitros, and euroimmun assays in detecting prior SARS-CoV-2 infection Longitudinal observation and decline of neutralising antibody responses in the three months following SARS-CoV-2 infection in humans Longitudinal evaluation and decline of antibody responses in SARS-CoV-2 infection Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections Longitudinal observation and decline of neutralising antibody responses in the three months following SARS-CoV-2 infection in humans Dynamics of IgG seroconversion and pathophysiology of COVID-19 infections Humanized single domain antibodies neutralise SARS-CoV-2 by targeting the spike receptor binding domain A SARS-CoV-2 surrogate virus neutralisation test based on antibody-mediated blockage of ACE2-spike protein-protein interaction Rapid decline of neutralising antibodies against SARS-CoV-2 among infected healthcare workers Detection of SARS-CoV-2 antibodies using commercial assays and seroconversion patterns in hospitalized patients Intrafamilial exposure to SARS-CoV-2 induces cellular immune response without seroconversion Severe acute respiratory syndrome coronavirus 2− specific antibody responses in coronavirus disease patients Orthogonal SARS-CoV-2 serological assays enable surveillance of low-prevalence communities and reveal durable humoral immunity This work was supported by the Bavarian State Ministry of Science and the Arts, the University Hospital, LMU Munich, the Helmholtz Centre Munich, the University of Bonn, the University of Bielefeld, and the German Ministry for Education and Research (project nr.: 01KI20271). Euroimmun, Roche, Mikrogen, Viramed provided kits and machines for analyses at discounted rates. The funders had no role in study design, data collection, data analysis, data interpretation, writing or submission for publication of this manuscript. We wholeheartedly thank all study participants for their trust, time, data, and samples. We are grateful for the financial support of the Conflicts of interest AW and MH report personal fees and non-financial support from Roche Diagnostics, LO reports non-financial support from Roche Diagnostics. AW, MH and LO report non-financial support from Euroimmun, non-financial support from Viramed, non-financial support from Mikrogen. AW, MH, LO report grants, non-financial support and other from German Centre for Infection Research DZIF, grants and non-financial support from Government of Bavaria, non-financial support from BMW, non-financial support from Munich Police, nonfinancial support and other from Accenture. JH reports grants from German Federal Ministry of Education and Research, during the conduct of the study. MH and AW report personal fees and nonfinancial support from Dr. Box-Betrobox, non-financial support from Dr. Becker MVZ during the conduct of the study. In addition, MH, AW, MB have a patent on a sample system for sputum diagnostics of SARS-CoV-2 pending. AW is involved in other different patents and companies not in relation with the serology of SARS-CoV-2. AW reports personal fees and other from Haeraeus Sensors, nonfinancial support from Bruker Daltonics, all of which are outside the submitted work, and non-related to SARS-CoV-2. MB is an authorised representative partner of Dr. Becker MVZ. The study was approved by the Ethics Committee of the Faculty of Medicine at LMU Munich (20-275 V) and the protocol is available online ( www. koco19. de) [13] . Informed consent was obtained prior to any study investigations where applicable. The study is registered in the German Clinical Trials Register (DRKS00021698; https:// www. drks. de/ drks_ web/ navigate. do? navigationId= trial. HTML and TRIAL_ID=DRKS00021698). Five reasons to publish your next article with a Microbiology Society journal 1 . The Microbiology Society is a not-for-profit organization. 2. We offer fast and rigorous peer review -average time to first decision is 4-6 weeks. 3. Our journals have a global readership with subscriptions held in research institutions around the world. 4. 80% of our authors rate our submission process as 'excellent' or 'very good'. 5. Your article will be published on an interactive journal platform with advanced metrics.Find out more and submit your article at microbiologyresearch.org.