key: cord-0867524-ucippa86 authors: Callahan, C.; Ditelberg, S.; Dutta, S.; Littlehale, N.; Cheng, A.; Kupczewski, K.; McVay, D.; Riedel, S.; Kirby, J. E.; Arnaout, R. title: Saliva Is Comparable to Nasopharyngeal Swabs for Molecular Detection of SARS-CoV-2 date: 2021-04-23 journal: nan DOI: 10.1101/2021.04.21.21255621 sha: a4b23192b32784c3beca8a09b3ba354e40147a97 doc_id: 867524 cord_uid: ucippa86 Abstract Background. The continued need for molecular testing for SARS-CoV-2 and promise of self-collected saliva as an alternative to nasopharyngeal (NP) swabs for sample acquisition led us to compare saliva to NP swabs in an outpatient setting, without special restrictions to avoid food, drink, smoking, or toothbrushing. Methods. A total of 385 pairs of NP and saliva specimens were obtained, the majority from individuals presenting for initial evaluation, and were tested on two high-sensitivity RT-PCR platforms: the Abbott m2000 and Abbott Alinity m, both with limits of detection (LoD) of 100 copies of viral RNA/mL. Results. Concordance between saliva and NP was excellent overall (Cohen's {kappa}=0.93) for initial as well as followup testing on both platforms, and for specimens treated with guanidinium transport medium as preservative and for untreated saliva ({kappa}=0.88-0.95). Viral loads were on average 16x higher in NP specimens than saliva specimens, suggesting that only the relatively small fraction of outpatients (~8% in this study) who present with very low viral loads (<1,600 copies/mL from NP swabs) would be missed by saliva testing relative to NP testing, for sensitive testing platforms. Special attention was necessary to ensure leak-resistant specimen collection and transport. Conclusions. The advantages of self-collection without additional restrictions will likely outweigh a minor potential decrease in clinical sensitivity in individuals less likely to pose an infectious risk to others for many real-world scenarios, especially for initial testing. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 23, 2021. likely outweigh a minor potential decrease in clinical sensitivity in individuals less likely to pose an infectious risk to others for many real-world scenarios, especially for initial testing. CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The currently accepted gold-standard method for diagnosing infection with SARS-CoV-2 is performing RT-PCR on nasopharyngeal (NP) secretions collected using an NP swab. This is choice is consistent with and was in part based on experience with other respiratory pathogens such as influenza viruses. However, this nasopharynx has the drawback of requiring experienced healthcare staff to perform sample collection, and such personnel are in chronic short supply. Also, requiring potentially infectious patients to congregate at a collection site is not ideal as it may inadvertently lead to iatrogenic infection. These suboptimalities have led to a number of investigations into whether and under what clinical circumstances alternative specimen types might be able to substitute for NP swabs [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] . Nasal secretions have the advantage of being able to be self-collected by swabbing the anterior nares; however, nasal secretions been shown to be less sensitive than NP secretions for viral loads below ~1,000 copies/mL [5, 6, 13] and still require a swab for collection (swabs have been in intermittently short supply over the course of the pandemic) [14] . Saliva has the advantage of requiring neither trained personnel nor a swab, making it an attractive alternative to both NP-and/or nasal-swab testing. Saliva can be self-collected using only a sterile container, making it amenable to at-home/off-site collection. Sensitive detection of respiratory viruses from saliva had been shown prior to the pandemic. [15, 16] . Consequently, saliva has been the subject of a number of studies in the context of the pandemic; however, these have reached varying conclusions regarding the suitability of saliva as an alternative to NP swabs, with some studies showing complete concordance and others only moderate agreement [9] . Known and potential reasons for these differences include timing/acuity of patients' clinical presentation, storage/processing conditions of collected samples, and sensitivity of the respective testing platforms used for detection of SARS-CoV-2. To address these issues, we compared saliva to NP swabs in 1,600 subjects across two testing platforms (Abbott m2000 and Abbott Alinity m) and two sample-processing approaches (untreated/"neat" and treated with guanidinium as a preservative) for individuals presenting for initial presentation vs. followup testing. Institutional review. This study was reviewed and approved by institutional review board at the Beth Israel Deaconess Medical Center (BIDMC; IRB protocol no. 2020P000769). CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted April 23, 2021. ; https://doi.org/10.1101/2021.04.21.21255621 doi: medRxiv preprint Trial design. This was a multi-arm study: initial vs. followup presentation, two different testing platforms (Abbott m2000 and Abbott Alinity m), and two different sample-processing pipelines for the saliva samples (unadulterated/"neat" saliva vs. preserved ("treated") with guanidinium isothiocyanate [GITC], i.e. Abbott multi-collect transport media, part of the Abbott Multi-Collect Specimen Collection Kit, catalog no. 09K12-004; Abbott Laboratories, Abbott Park, IL). See Fig. 1 . Trial participants and sample collection. Informed consent was obtained from Englishspeaking adults presenting for either initial or followup testing for COVID-19 at BIDMC and Beth Israel Deaconess Chelsea drive-through collection sites. Saliva specimens. While waiting in line for NP testing, each participant was given a sterile sample collection cup (VWR International, part no. 76299-868) and asked to spit/drool to a clearly labeled 3mL fill line. No exclusions were made on the basis of recent consumption of food or drink or of smoking, and participants were not asked to rinse the mouth or perform any other preparation ahead of sample collection. They were informed that 3mL is a large amount of saliva and may take several minutes/deposits to achieve, and told that thinking of a favorite food may help trigger salivation. They were told to close the cup tightly when finished and to hand it to the healthcare worker who would be acquiring the NP specimen. NP specimens. NP specimens were collected per standard protocol. Briefly, the NP swab was inserted into the nasopharynx and rotated for 10 seconds, removed, and placed in a vial containing viral transport media [17] . Transport. Saliva specimens were individually bagged and transported together with the NP specimen via courier to BIDMC's central laboratory for testing. Courier frequency was every 1-2.5 hours, with the maximum transport time to the laboratory being approximately 20 minutes. Specimens were transported at room temperature. At the BIDMC Pathology central laboratory, specimens were logged in and processed for testing as described below. Sample processing. For GITC-treated saliva samples, 1mL of saliva was added to the multi-Collect tube that contains 1.25mL GITC buffer ("treated"). For untreated saliva samples, 1mL was used "neat." Samples with <1mL were excluded. At the start of the study, treated, untreated, and a 1mL aliquot of NP sample from the same participant were briefly vortexed (2-5 seconds) and amplified using Abbott m2000 RealTime is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 23, 2021. ; https://doi.org/10.1101/2021.04.21.21255621 doi: medRxiv preprint SARS-CoV-2 Assay on an Abbott m2000 RealTime System or the Abbott Alinity m system. After 16 positive untreated specimens were analyzed on the m2000, the untreated arm was abandoned in favor of the treated arm. Thereafter, treated specimens were stored at 4°C until the paired NP sample had resulted. If the NP sample was positive, the GITC sample was run alongside an additional 1mL aliquot from the NP sample. Categorical (positive vs. negative), Ct, and IC values were recorded. Cutoff for positive was a Ct value of 31.5 on the m2000 and 42 on the Alinity m. Limits of detection (LoD). NP. The LoD for SARS-CoV-2 from NP swabs was validated at 100 copies/mL on both the m2000 and Alinity m platforms, as described previously [18] . Statistical analyses. For concordance testing, RT-PCR results were considered categorically as either positive or negative; testing agreement was assessed by Cohen's kappa (κ) [19] . Conversion to viral load was performed as described previously [20] . "Initial testing" was defined as testing of a saliva sample collected fewer than five days after the first COVID-19 RT-PCR test. "Followup testing" was defined as testing occurring thereafter. Leaking samples and internal-control failures were omitted from analysis. Significance testing. We tested whether Ct values for a given subset of saliva samples differed from the Ct values for the paired NP swabs (the controls) using Wilcoxon's signed rank test. This tested the null hypothesis that values for controls and prototypes are drawn from the same underlying distribution. The Benjamini-Hochberg approach [21] was used to control the falsediscovery rate (FDR) at 1%. Software. We used Python (v3.6-3.8) and its NumPy, SciPy, Matplotlib, Pandas, and ct2vl libraries for the above analyses and related visualizations. Figure 1 depicts the design of this study of adults being tested by RT-PCR for infection with SARS-CoV-2 and the numbers of participants tested in each arm. Participants waiting for NP sample collection were asked to spit into a sterile urine cup clearly marked with a 3-mL fill line until the line was reached. Participants were informed that this would likely require spitting more than once, encouraged to persist despite any embarrassment or distaste/mild disgust, and instructed to thread the lids carefully and close them tightly to avoid leaking. Study staff retightened cups as necessary. Saliva specimens were double bagged and shipped alongside the NP specimen. Overall, this limited the incidence of leaking saliva, which was encountered frequently initially. LoDs of 45 copies/mL in treated and 104 copies/mL in untreated saliva (76 copies/mL combined), statistically comparable to the previously validated LoD for NP swabs on these platforms, 100 copies/mL (Fig. 2) . (Note that treatment results in a roughly 2-fold dilution of the sample.) Stability of SARS-CoV-2 in saliva over time. Replication-incompetent, enveloped, positive single-stranded RNA Sindbis virus into which SARS-CoV-2 genomic material was cloned as a non-infectious SARS-CoV-2 surrogate was stable in untreated saliva at room temperature, with concentration falling by ~3 fold within the first four hours but then staying stable at that level through two days (Fig. 3 ). Saliva treated with the preservative GITC was stable for at least 24 hours. Together, these findings support the viability of workflows in which, as a limiting timeline, saliva is collected and transported "neat" and treated with GITC within two days for subsequent testing. Comparison of saliva to NP swabs. Overall, saliva results were highly concordant (Cohen's κ=0.93) with results from paired NP swabs obtained from participants in a medium-to-high prevalence population(~20% positivity) who presented for screening and follow-up, as tested on two sensitive RT-PCR platforms, the Abbott Alinity m and Abbott m2000 (LoD 100 copies/mL) (Fig. 4) . Using the LoD as the cutoff, there were only nine discordant results among 385 paired samples, and these were evenly balanced (4 NP-swab-positive/saliva-negative samples vs. 5 saliva-positive/NP-swab-negative samples). Despite the high concordance, (geometric) mean viral load in NP samples was ~16 times as high as in saliva samples (3.1 million vs. 200,000 copies/mL, respectively; Wilcoxon p value for difference of saliva vs. NP viral load distributions, 2×10 -6 ). These trends were robust across all subgroups analyzed, whether by initial testing (n=343, κ=0.93) or follow-up testing (n=42, κ=0.88); whether samples were treated with GITC as soon as they reached the laboratory (Fig. 5) (n=316, κ=0.92) or not (n=69, κ=0.95); and whether they were run on the Alinity m (n=207, κ=0.91) or m2000 (n=178, κ=0.94). Notably, mean viral load for NP-swab samples was 13 times as high as for saliva samples treated with GITC vs. 40 times as high for untreated saliva samples. Mean viral load was 2-3x as high for participants presenting for their initial COVID-19 test vs. follow-up (3.7 million vs. 1.5 million copies/mL, respectively, as measured on NP samples, and 240,000 vs. 81,000 copies/mL, respectively, as measured on saliva samples). While saliva testing has shown promise as a suitable specimen for detection of several viral respiratory pathogens [8] [9] [10] 15] , NP swabs remain the gold standard in most clinical settings, requiring well-trained healthcare staff to obtain them. The demands of the COVID-19 pandemic have led to a number of investigations of saliva for molecular detection of SARS-CoV-2 in a wide range of clinical and non-clinical settings and with a variety of patient instructions and processing steps, with the overall conclusion that saliva is comparable to but slightly inferior to NP swabs [22] . Some studies have instructed patients to provide morning specimens or to abstain from eating/drinking/smoking before providing a specimen, constraints that complicate collection. We sought to test how well saliva testing in a real-world outpatient setting without any such constraints would perform, with the only special handling step being adding a preservative, in the form of GITC transport buffer once the specimen arrived from the outpatient site to our hospital's central laboratory for testing. The overall results in our current study were consistent with previous work [22] , with very high concordance between saliva and NP swabs under all scenarios tested. A minor but surprisingly important observation was the importance of leak-resistant collection cups, as a substantial number of collected specimens were unusable due to leaks, despite proper instruction for sample collection. The leak-resistant cups we adopted mitigated leaking somewhat, as they incorporated a soft gasket-like seal inside the lid, with a thread length to pitch ratio of ~3. Cups using a more deformable gasket or larger ratio may further reduce sample leakage. Nevertheless, our experience demonstrates that simple and readily available specimencollection cups can be repurposed for saliva collection for respiratory-virus testing. Usefully, we observed high concordance without any restrictions on participant activities (eating/drinking/smoking/tooth brushing; the color and heterogeneity of several saliva samples was highly suggestive of these activities); without asking participants to rinse, cough, or retch; and without requiring specimens to be obtained in the morning (indeed most of samples were collected in the early afternoon). While it cannot be ruled out that these additional requirements might improve performance (~5% improvement in concordance in meta-analysis (20) ), the results of the present study suggest that the procedural hurdles of obtaining specimens with these constraints likely outweigh any modest incremental benefit. Furthermore, we demonstrated that SARS-CoV-2 viral material was stable in GITC-treated saliva for at least 24 hours. The time between sample collection and addition of GITC never exceeded 12 hours. Treatment was performed in the laboratory and not earlier, at the collection site, for simplicity of workflow. We chose not to include the preservative in the specimen- is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 23, 2021. ; https://doi.org/10.1101/2021.04.21.21255621 doi: medRxiv preprint collection cups for concern over potential exposure of participants to a caustic substance. The median time between specimen collection and addition of GITC was approximately 6 hours (Fig. 5 ); however, we demonstrated that viral material is fairly stable in saliva at room temperature without preservative, retaining approximately half of viral load at 24 hours and a third at 45 hours, allowing room-temperature transport and login times of over a day. Consistent with these stability studies, untreated saliva samples showed indistinguishably high concordance with NP swabs compared to GITC-treated saliva samples (Fig. 4d-e) , although the mean viral load in untreated samples was approximately 3x lower (also consistent with stability studies). Despite the high concordance overall (κ=0.93) and for all subgroup analyses (κ=0.88-0.95), including for participants presenting for follow-up as well as during initial presentation, the onaverage 13x higher viral load detected by NP swabs vs. paired GITC-treated saliva specimens deserves mention. Provided that viral load (as measured by NP swab) is greater than 13 times the platform's LoD (100 copies/mL in our study), saliva treated with GITC within 24 hours of collection is highly likely to detect infection. However, viral loads less than this threshold (1,300 copies/mL) may be missed. In our study, approximately 92% of initial presentations were above this threshold. The analogous ratio for untreated saliva was 40x, corresponding to a threshold of 4,000 copies/mL; approximately 90% of initial presentations were above this threshold. We conclude that saliva can be fairly expected to detect over 90% of initial SARS-CoV-2 infections in an outpatient setting. To the extent that more severe disease correlates with higher viral loads, performance in inpatient settings is likely to be even higher. Furthermore, a detection level in saliva that would correspond to 4,000 copies/mL in NP swab samples is likely to capture those who are infectious and is also likely significantly below the limit of detection of currently marketed SARS-CoV-2 antigen tests [20] . In conclusion, we have demonstrated that saliva is comparable to NP-swab collection for molecular detection of SARS-CoV-2 in an outpatient setting, with the disadvantage of slightly lower viral loads. This loss in sensitivity must be weighed against the ease of self-collection. However, we have demonstrated that use of saliva for SARS-CoV-2 molecular detection is both feasible and practical, given suitable specimen-collection containers and transport and processing protocols. CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted April 23, 2021. ; https://doi.org/10.1101/2021.04.21.21255621 doi: medRxiv preprint A combined oropharyngeal/nares swab is a suitable alternative to nasopharyngeal swabs for the detection of SARS-CoV-2 Comparison of Abbott ID Now, Diasorin Simplexa, and CDC FDA EUA methods for the detection of SARS-CoV-2 from nasopharyngeal and nasal swabs from individuals diagnosed with COVID-19 Saliva as an Alternate Specimen Source for Detection of SARS-CoV-2 in Symptomatic Patients Using Cepheid Xpert Xpress SARS-CoV-2 Self-Collected Oral Fluid and Nasal Swabs Demonstrate Comparable Sensitivity to Clinician Collected Nasopharyngeal Swabs for Covid-19 Detection Sensitivity of Nasopharyngeal, Nasal and Throat Swab for the Detection of SARS-CoV-2 Nasal-Swab Testing Misses Patients with Low SARS-CoV-2 Viral Loads Saliva is a reliable tool to detect SARS-CoV-2 Evaluation of specimen types and saliva stabilization solutions for SARS-CoV-2 testing Clinical Evaluation of Self-Collected Saliva by Quantitative Reverse Transcription-PCR (RT-qPCR), Direct RT-qPCR, Reverse Transcription-Loop-Mediated Isothermal Amplification, and a Rapid Antigen Test To Diagnose COVID-19 Saliva-Based Molecular Testing for SARS-CoV-2 that Bypasses RNA Extraction. Microbiology Saliva is more sensitive than nasopharyngeal or nasal swabs for diagnosis of asymptomatic and mild COVID-19 infection Patient-collected tongue, nasal, and mid-turbinate swabs for SARS-CoV-2 yield equivalent sensitivity to health care worker collected nasopharyngeal swabs Nasal Swab Sampling for SARS-CoV-2: a Convenient Alternative in Times of Nasopharyngeal Swab Shortage Open Development and Clinical Validation of Multiple 3D-Printed Nasopharyngeal Collection Swabs: Rapid Resolution of a Critical Saliva as a diagnostic specimen for testing respiratory virus by a point-of-care molecular assay: a diagnostic validity study. Clinical Microbiology and Infection: The Official Publication of the European Society of Clinical Microbiology and Infectious Diseases Additional molecular testing of saliva specimens improves the detection of respiratory viruses Large-scale, in-house production of viral transport media to support SARS-CoV-2 PCR testing in a multi-hospital healthcare network during the COVID-19 pandemic The Limit of Detection Matters: The Case for Benchmarking Severe Acute Respiratory Syndrome Coronavirus 2 Testing Interrater reliability: the kappa statistic The Limit of Detection Matters: The Case for Benchmarking Severe Acute Respiratory Syndrome Coronavirus 2 Testing Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing Performance of Saliva, Oropharyngeal Swabs, and Nasal Swabs for SARS-CoV-2 Molecular Detection: A Systematic Review and Meta-analysis International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity The authors gratefully acknowledge the participation of patients and staff at Beth Israel Deaconess Healthcare | Chelsea for making this study possible. We also acknowledge critical reading of the manuscript, as well as study design input by Joshua Kostera. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 23, 2021. ; https://doi.org/10.1101/2021.04.21.21255621 doi: medRxiv preprint . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 23, 2021.