key: cord-0866677-03a6hq3t authors: Moore, Matthew D.; Jaykus, Lee-Ann title: Development of a Recombinase Polymerase Amplification Assay for Detection of Epidemic Human Noroviruses date: 2017-01-09 journal: Sci Rep DOI: 10.1038/srep40244 sha: 80514d274dfaa180080c8eb0bb261c0af5c95c49 doc_id: 866677 cord_uid: 03a6hq3t Human norovirus is a leading cause of viral gastroenteritis worldwide. Rapid detection could facilitate control, however widespread point-of-care testing is infrequently done due to the lack of robust and portable methods. Recombinase polymerase amplification (RPA) is a novel isothermal method which rapidly amplifies and detects nucleic acids using a simple device in near real-time. An RT-RPA assay targeting a recent epidemic human norovirus strain (GII.4 New Orleans) was developed and evaluated in this study. The assay successfully detected purified norovirus RNA from multiple patient outbreak isolates and had a limit of detection of 3.40 ± 0.20 log(10) genomic copies (LGC), which is comparable to most other reported isothermal norovirus amplification methods. The assay also detected norovirus in directly boiled stool, and displayed better resistance to inhibitors than a commonly used RT-qPCR assay. The assay was specific, as it did not amplify genomes from 9 non-related enteric viruses and bacteria. The assay detected norovirus in some samples in as little as 6 min, and the entire detection process can be performed in less than 30 min. The reported RT-RPA method shows promise for sensitive point-of-care detection of epidemic human norovirus, and is the fastest human norovirus amplification method to date. designed that would accommodate all 8 sets ( Table 1 ). The primer sets were then tested for the time to fluorescence threshold with the probe and compared (Fig. 1) . Six primer sets produced signal with the probe, and two of the sets-NOF5-NOR11 and NOF5-NOR12-produced signal significantly (p < 0.05) faster than three other sets and also performed similarly when used on heated stool (data not shown). One set was discarded because it produced signal with widely inconsistent time to result. Due to resource constraints, one set (NOF5-R11 with NOP1) was chosen for subsequent evaluation. Evaluation of RT-RPA performance with GII.4 New Orleans outbreak samples. RT-RPA performance was tested using serially diluted stool samples obtained from 12 different individuals during 10 different GII. 4 New Orleans outbreaks that occurred in 2012. Two sample preparation methods were analyzed for each of the samples-conventional RNA purification and direct detection after boiling of patient stool ( Table 2) . RT-RPA applied to serially-diluted purified RNA samples produced signal for a wide range of virus input levels, was highly repeatable, and identified virus in all patient samples. RNA copy number over a range of 0.2 log 10 genomic copies (LGC) to 9. 4 LGC per reaction produced positive signal fluorescence within 6.1 min to 21.5 min. Overall for purified RNA, the input LGC of RNA as determined by RT-qPCR was inversely proportional to the time to signal of the RT-RPA when analyzed by linear regression ( Figure S2 ). When applied to heated stool, RT-RPA did not perform as well, but positive signal was still repeatedly produced for all outbreak-derived stool samples except one (sample 44), with estimated input genome concentration ranging from 0. 8-10.0 LGC and positive signal produced in 6.7-20.0 min. For most boiled stool samples, the RT-RPA produced positive signal for samples with high levels of inhibitors. For example, for relatively "dirty" samples (20% and 2% fecal suspensions), RT-RPA produced more positive replicates than did RT-qPCR, with 61% versus 18% positive replicates for 20% stool, and 61% versus 58% for 2% stool, respectively ( Figure S1 ). Supplementation of reactions with dimethyl sulfoxide (DMSO), formamide, and RNase inhibitor did not improve the results of the RT-RPA assay ( Figure S3 ). To test the analytical sensitivity (detection limit) of the RT-RPA assay, serial dilutions of purified GII.4 New Orleans RNA from three patients (isolates 29, 47, and 58) were tested for 8 replicates and probit regressions used to interpolate a limit of detection (Fig. 2 ). The range of input RNA producing consistently positive results for all three replicates was 3.2 to 6.2 LGC with time to threshold florescence of 12.4 ± 2.4 min to 8.2 ± 0.5 min, respectively. Based on the probit regressions average, the limit of detection of the assay (the level of input RNA for which 95% of samples would be positive) is 3.40 ± 0. 20 LGC. This is about 1.0 LGC higher than the limit of detection determined for RT-qPCR, which was predicted by probit to be 2.3 ± 0.04 LGC. The specificity of the RT-RPA was determined using a panel of genomes extracted from relevant enteric virus and bacterial cultures (Table 3) . Consistent positive signal was only observed for both GII.4 human norovirus strains. Human norovirus GII.3 produced positive signal for one replicate at one dilution, but was otherwise negative. The GII.4 Sydney strain, the most recent circulating epidemic strain 10 , repeatedly produced positive signal in 8.1-15.3 min over a 3.0 LGC range of input RNA. The repeatable amplification and positive signal of GII.4 Sydney suggests that some degree of base mismatching is tolerated in the RT-RPA system, despite its reliance on recombinase enzymes (Table 4 ). There were a total of 6 mismatches in the assay's targeted region when comparing GII.4 New Orleans and Sydney strains, whereas there were 16 mismatches when comparing GII.3 with GII.4 New Orleans. Sydney does not differ from New Orleans in the probe region and has only 4 and 3 base mismatches in the forward and reverse primer target regions, respectively. GII.3 has 3 probe, 2 forward, and 11 reverse primer target region mismatches. It is likely that the reverse primer target region is the reason for the lack of consistent reactivity for GII.3. In this work, a RT-RPA assay for the rapid detection of GII.4 human norovirus was developed and proof-of-concept data provided for its use in detecting virus in representative clinical samples. In purified RNA extracts, the assay limit of detection was 3.40 LGC per reaction. When human fecal samples positive for norovirus GII.4 New Orleans were extracted for RNA isolation followed by RT-RPA, virus could be detected in all patient specimens, with longer amplification times to target signal corresponding to lower input template concentrations. It was possible to detect norovirus when 20% fecal specimens were heated to release the viral RNA, without further purification. With this heat release method, lower limits of detection were around 5.0 LGC per reaction. Although not as sensitive as the RT-qPCR, the RT-RPA assay appears to have similar analytical sensitivity to conventional RT-PCR and other human norovirus isothermal assays 11, 12 . For point-of-care diagnostics in particular, isothermal amplification methods are of great interest due to their convenience, rapid time-to-result, and potential for miniaturization. Two of these methods have been well studied for human norovirus detection: nucleic acid sequence based amplification (NASBA) and loop-mediated isothermal amplification (LAMP). Greene et al. 12 developed the first norovirus NASBA, targeting Norwalk virus, reporting a detection limit of 10 4 PCR-amplifiable units/ml sample and a total time-to-result of 4-6 h. Moore et al. 13 evaluated the sensitivity and specificity of this same NASBA using GI, GII, and outbreak strains. The method 34 3.0-9.0 7.4 ± 0.5-13.4 ± 2.6 5.0 (3/3) 3.6-9.6 7.8 ± 1.5-11.8 ± 0.0 c 6.6 (1/3) 3.6-9.6 7.5 ± 0.1-9.9 ± 0.9 7.6 (3/3) Table 2 . RT-RPA performance with purified RNA and heated stool samples. Twelve outbreak stool specimens previously confirmed positive for GII.4 New Orleans were diluted 20% in PBS and either subjected to genomic RNA purification with serial dilution or serially diluted and boiled at 99 °C. a The input range tested for each sample. b The lowest input level for which a signal was obtained along with the proportion of replicates the signal was obtained for that input level. c No standard deviation observed due to only one positive replicate. was able to detect 13/17 of the strains tested and, compared to the RT-PCR "gold standard, " had a sensitivity and specificity of 100% and 80%, respectively. A different NASBA assay design targeting the ORF1-ORF2 junction and using the JJV2F and COG2R primers 14, 15 reportedly had higher analytical sensitivity, approximately 90% concordance with other assays, and reduced time-to-result (90 min) 16 . The first human norovirus LAMP assay targeted a similar genome region to the RT-RPA, was designed to detect both GI and GII viruses, and had a detection limit of 2-3 LGC/25 μ l reaction. Sensitivity and specificity approached 100% and results were achieved in 60-90 min 11 . Yoda et al. 17 designed their own LAMP assay targeting the ORF1-ORF2 junction and were able to improve on the detection limit (to 1-2 LGC/25 μ l reaction) and increase inclusivity by design changes. In another study, Iturriza-Gomara et al. 18 evaluated a commercial RT-LAMP for norovirus detection relative to an RT-PCR, finding a slightly lower sensitivity for the GI RT-LAMP but a higher sensitivity for the RT-LAMP assay. Newer LAMP designs are facilitating colorimetric endpoints and can be used even for genotyping 19, 20 . Although several isothermal techniques for the amplification and detection of purified nucleic acids exist 21, 22 , RPA has multiple advantages, i.e., (i.) the use of a single tube; (ii.) real-time detection of amplified product using a fluorescent probe; (iii.) the inclusion of most required reagents in the form of a freeze-dried pellet to simplify testing; (iv.) the inclusion of a binding protein that has been reported to aid in amplification of RNA targets having Table 3 . Exclusivity (specificity) analysis. The genomic RNA/DNA of several enteric viruses and bacteria was extracted using a NucliSens EasyMAG (bioMerieux), and 10 −2 and 10 −3 dilutions of the extracts were loaded as template in the RT-RPA assay using the G2F5-G2R11-G2P1 primer-probe set. c Showed low reactivity in one replicate. a Source organism type used. All organisms may be present in human enteric samples. b Whether or not an amplifiable signal was observed at any point for any dilution with RT-RPA. If yes, then the proportion of replicates for which a positive signal was obtained is presented in parentheses. Scientific RepoRts | 7:40244 | DOI: 10.1038/srep40244 a high degree of secondary structure; and (v.) a reduced time to a positive signal. A disadvantage with respect to human norovirus detection may be lack of broad reactivity (i.e., high specificity), perhaps because the recombinase enzyme used is thought to have higher fidelity than PCR 6, 7 . However, in our work some degree of base mismatch appears to have been tolerated as we were able to detect two different GII.4 strains, although older strains have not been evaluated. However, having a method that reliably detects GII.4 norovirus is relevant as this genotype is responsible for at least 70% of norovirus cases in the United States 23 and 80-95% of outbreaks globally 24 . New RT-RPA assays could be redesigned relatively quickly to cover new epidemic strains as they emerge. With the exception of the early work of Greene et al. 12 , this is the first study of isothermal amplification in which fecal suspensions without prior RNA extraction were used as template. Our results are generally consistent with Greene et al. 12 in that the RT-RPA assay produced more positives in samples with higher concentrations of fecal material as compared to RT-qPCR. Specifically, for our study's comparisons of sample positivity for 20% stool suspensions, about 60% were positive by RT-RPA while less than 20% of those same samples were positive by RT-qPCR ( Figure S1 ). This suggests that the RT-RPA method may have more tolerance for inhibitory compounds. When RPA was used for the direct detection of Chlamydia trachomatis from urine samples, no notable amplification inhibition occurred, although it was common when using PCR 25 . The authors hypothesized that RPA would be less susceptible to amplification inhibition because the assay relies on enzyme components and conditions more comparable to biological systems. For example, the use of a recombinase enzyme may provide increased primer binding efficiency. A polymerase derived from a bacterial species (Bacillus subtilis) that can grow at 37 °C may be more physiologically familiar, as would be an amplification reaction occurring under isothermal conditions of 40 °C 7 . Interestingly, the isothermal LAMP assay has also been shown to have a higher tolerance for inhibitors in other biological samples [26] [27] [28] . For instance, Enotomoto et al. 28 successfully directly detected herpes simplex virus-1 (HSV-1) in swab samples from patients with gingiovostomatitis or vesicular skin eruptions. In the same year, Kaneko et al. 27 found similar evidence for HSV-1 and HSV-2 with a LAMP assay considerably outperforming PCR when samples were directly amplified without DNA purification in patients with genitalitis, keratitis, and uveitis. Perhaps the most comprehensive evaluation of the sample matrix on isothermal amplification, Kaneko et al. 26 evaluated the HSV-1 LAMP assay relative to PCR in saline solution, PBS, Modified Eagle's Medium, serum, plasma, urine, aqueous, and vitreous solutions of different concentrations spiked with a low level of HSV-1 DNA. Although inhibition was inevitably noted at high concentrations for both assays, LAMP outperformed PCR 26 . However, further comparisons of isothermal methods to PCR are necessary before broad conclusions about the impact of inhibitors on amplification efficiency can be made. This GII.4 norovirus RT-RPA assay displayed poorer analytical sensitivity (detection limit) than several previously reported assays for other viral pathogens. These earlier studies used an RNA standard to determine analytical sensitivity and showed RT-RPA detection limits < 1 LGC for bovine coronavirus 9 , and Rift Valley fever, Ebola, Marburg, Sudan and Sigma viruses 29, 30 . This is 2 LGC better than the limit of detection reported for our assay. However, our limit of detection was similar to that reported for a foot and mouth disease virus assay (3.16 LGC) 31 . There are a number of explanations for the differences in detection limits reported in the literature. Firstly, in the earlier studies, detection limits were based on an RNA standard generated from a plasmid, while our study used RNA directly purified from clinical samples. We believe that the latter approach, while producing higher detection limits, is more biologically relevant, because a full length genome may consume more RPA enzyme and also contain regions of increased secondary structure, both of which can impede enzymatic action 32 . Alternatively, the length of the amplicon reported here is longer than those reported by Euler et al. 29, 30 and Amer et al. 9 , but is similar in length to that reported by Abd El Wahed et al. 31 , who showed a similar higher limit of detection. The RT-RPA assay was able to amplify the two most recent circulating epidemic GII.4 norovirus strains. This implies that despite its high fidelity, the assay is able to tolerate slight differences in target sequence. This is in agreement with Boyle et al. 33 , who reported that two different HIV-1 RPA primer-probe sets were capable of amplifying nearly all HIV-1 subtypes, including one isolate with 9 mismatches. In our report, GII.4 Sydney containing 6 total mismatches in the target region was readily amplified. The data of Daher et al. 34 , which focused on using RPA for amplification of conserved genes for several bacteria, showed a similar tolerance to base pair mismatches. Interestingly, the GII.3 template was inconsistently amplified by the NOF5-NOR11-NOP1 primer-probe set, the amplified region of which contained base mismatches on the 3′ end of NOF5 and NOR11 target regions in addition to a large number of mismatches (Table 4 ). Such placement of mismatches was found by Daher et al. 34 to be more inhibitory to amplification than internal or 5′ mismatches. The fact that the primer-probe set reported here did not amplify any other relevant enteric virus or bacterial nucleic acid suggests that it shows good specificity, reducing the likelihood of false positives. However, future studies building upon the foundational work presented here analyzing a larger number and diversity of human norovirus clinical samples must be completed to validate and evaluate the suitability of this assay for large scale clinical settings. For instance, analysis of the Table 4 . Sequence alignment of GII.4 strains and GII.3. The sequences of GII.4 New Orleans and Sydney strains as well as a GII.3 strain were aligned using the Mega 6 software package. Bolded sequences correspond to the NOF5 and NOR11 target sequence regions, with base mismatches for Sydney and GII.3 colored red. Probe target regions were excluded because there were 0 and 3 mismatches with New Orleans as compared to Sydney and GII.3, respectively. assay's reactivity with earlier strains of the GII.4 genotype and reactivity with the GII.17 genotype that is emerging as a genotype of significance 35 would be valuable future work. Another logical future direction to build on this work would be to design and optimize more degenerate primer-probe sets and potentially multiplex the assay for immediate genogrouping analysis. This is the first report on the use of the emerging RPA technology for the rapid detection of human norovirus. RT-RPA has multiple advantages over RT-qPCR, including: (i.) the lack of reliance on larger, more expensive equipment for amplification and detection; (ii.) the use of recombinase enzymes that reduce the likelihood of false positive results due to their inherent proofreading capabilities 6, 7, 36 ; (iii.) quicker time-to-result; and (iv) the potential for reduced impact of matrix-associated inhibitors. Theoretically, the RT-RPA assay is capable of direct, portable detection of epidemic human norovirus in clinical samples with minimal expertise in less than 30 minutes. With further optimization, in particular improvement of analytical sensitivity and comprehensive evaluation of assay specificity, RT-RPA has potential to be a promising alternative to RT-qPCR or other isothermal methods for rapid testing for human norovirus. Generation of a human norovirus RNA Standard by RT-qPCR. The amplifiable genomic copies of a sample was determined using an RNA standard curve as previously described 37 . Briefly, extracted GII.4 New Orleans RNA (Accession Number: JN595867) was first amplified with T7GII.4F and GII.4R primers (Table 1) using the Superscript One-Step RT-PCR kit (Invitrogen, Carlsbad, CA) and 5 μ l template. A 15 min reverse transcription cycle at 50 °C was then followed by enzyme inactivation at 95 °C for 2 min. Amplification was performed for 30 cycles of 95 °C for 15 sec, 55 °C for 30 sec, and 72 °C for 30 sec. The 460 nucleotide amplicon was gel purified using the QIAquick gel extraction kit (Qiagen, Hilden, Germany) and subjected to in vitro transcription using the MEGAshortscript T7 kit (Thermo Fisher, Waltham, MA) according to manufacturer's instructions. The transcribed RNA was purified and quantified (NanoPhotometer Pearl, Denville Scientific, South Plainfield, NJ). It was then serially diluted and used to construct a standard curve with RT-qPCR using the JJV2F-COG2R-Ring2-TP primer probe set (Table 1 ) and the SuperScript One-Step RT-PCR kit with 45 cycles and a 54 °C annealing temperature. The RNA standard curve was used to estimate RNA copy number from extracted patient stool samples. Cq was evaluated with a threshold of 30 flourescence units using Bio-Rad CFX Manager software. All reactions were performed in triplicate. Real time RT-RPA primer and probe design. Primers for RT-RPA were designed following manufacturer guidelines (TwistDx Inc. Cambridge, UK). Targets for primer design were the relatively conserved ORF1-2 junction and a previously reported conserved region of the norovirus capsid near the N/S domain of ORF2 15, 38 . After initial screening, one optimally performing primer set was selected and the corresponding probe was designed according to manufacturer's instructions (TwistDx Inc.) ( Table 1 ). Primers were provided by Integrated DNA Technologies (IDT, Coralville, IA) and probes were provided by Biosearch Technologies (Novato, CA). RT-RPA reaction conditions. RT-RPA reactions were carried out using the TwistAmp exo RT kit (TwistDx Inc.). Each 50 μ l reaction contained 2.1 pmol forward and reverse primer, 0.6 pmol probe, 29.5 μ l proprietary rehydration buffer, 10 μ l template, and nuclease-free water to 47.5 μ l. The reaction mixture was then added to rehydrate TwistAmp exo RT lyophilized enzyme pellets, and 2.5 μ l of 280 mM magnesium acetate was added to the tops of reaction tube lids. The magnesium acetate droplets were then spun down using a minifuge and a timer immediately started. Reactions were quickly transferred to a Bio-Rad CFX Thermal Cycler (Bio-Rad, Hercules, CA) set to 40 °C with cycles read every 30 sec. Five min after the reactions were started, the cycler was paused, reactions mixed, spun down, and placed back on the thermal cycler to continue cycling. The total time to produce signal was calculated by the following equation (1) Evaluation of purified RNA and heated stool samples using RT-RPA and RT-qPCR. Twenty percent suspensions of norovirus GII.4 New Orleans-confirmed clinical samples from 12 patients were serially diluted and the RNA released by heating in a Bio-Rad T100 Thermal Cycler (Bio-Rad, Hercules, CA) at 99 °C for 5 min. Tubes were cooled on ice, mixed and briefly centrifuged. These heated stool dilutions were used directly as a template in RT-RPA reactions as described above, and in RT-qPCR reactions using the JJV2F-COG2R-Ring2-TP Scientific RepoRts | 7:40244 | DOI: 10.1038/srep40244 primer probe set (Table 1 ). In addition, NucliSENS ® easyMAG RNA extracts from each clinical sample were serially diluted and used in RT-RPA and RT-qPCR. The degree of correlation between RT-RPA time to detection (in min) and log 10 genomic copy input (by standard curve) was determined by linear regression using Microsoft Excel 2013 ( Figure S2 ). For evaluating the RT-RPA assay analytical sensitivity, serial dilutions of purified RNA from three selected stool samples (samples 29, 47 , and 58) were tested using as described above for a total of 8 replicates and a probit regression was performed for each using the JMP 12 software package (SAS, Cary, NC). The limit of detection and standard deviation was calculated by averaging the three values produced by the regressions. Each value reflected the predicted LGC for which 95% of tests would produce a positive result. All reaction sets included no template controls to confirm lack of contamination. Exclusivity testing and sequence analysis. The specificity was evaluated by analyzing multiple relevant enteric virus and bacterial strains for cross reactivity with the RT-RPA assay (Table 3) . Purified genomic nucleic acid was serially diluted, and 10 −2 and 10 −3 dilutions used directly as templates in RT-RPA. To analyze the degree of sequence difference between GII.4 New Orleans, for which the primers were designed, and two other human norovirus strains (GII.3 and GII.4 Sydney), sequences were aligned by performing Clustal W analysis using the MEGA 6 Software suite 39 . Global prevalence of norovirus in cases of gastroenteritis: a systematic review and meta-analysis Economic burden from health losses due to foodborne illness in the United States Economic value of norovirus outbreak control measures in healthcare settings Economic Impact of Outbreaks of Norovirus Infection in Hospitals Sample preparation prior to molecular amplification: Complexities and opportunities DNA detection using recombination proteins Recombinase polymerase amplification assay for rapid detection of Francisella tularensis A new approach for diagnosis of bovine coronavirus using a reverse transcription recombinase polymerase amplification assay Indications for worldwide increased norovirus activity associated with emergence of a new variant of genotype II.4, late 2012 Rapid Detection of Norovirus from Fecal Specimens by Real-Time Reverse Transcription -Loop-Mediated Isothermal Amplification Assay Evaluation of the NucliSens ® Basic Kit assay for detection of Norwalk virus RNA in stool specimens Evaluation of a broadly reactive nucleic acid sequence based amplification assay for the detection of noroviruses in faecal material Rapid and Sensitive Detection of Noroviruses by Using TaqMan-Based One-Step Reverse Transcription-PCR Assays and Application to Naturally Contaminated Shellfish Samples Broadly reactive and highly sensitive assay for Norwalk-like viruses based on real-time quantitative reverse transcription-PCR Real-time molecular beacon NASBA for rapid and sensitive detection of norovirus GII in clinical samples Evaluation and Application of Reverse Transcription Loop-Mediated Isothermal Amplification for Detection of Noroviruses Evaluation of the Loopamp (loop-mediated isothermal amplification) kit for detecting Norovirus RNA in faecal samples Visual Detection of norovirus genogroup II by reverse transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye Simultaneous detection and genogroup-screening test for norovirus genogroups I and II from fecal specimens in single tube by reverse transcription-loop-mediated isothermal amplification assay Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review Nucleic acid isothermal amplification technologies: a review Genotypic and epidemiologic trends of norovirus outbreaks in the United States Systematic literature review of role of noroviruses in sporadic gastroenteritis Sensitive and rapid detection of chlamydia trachomatis by recombinase polymerase amplification directly from urine samples Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances Sensitive and Rapid Detection of Herpes Simplex Virus and Varicella-Zoster Virus Rapid Diagnosis of Herpes Simplex Virus Infection by a Loop-Mediated Isothermal Amplification Method Recombinase polymerase amplification assay for rapid detection of Rift Valley fever virus Development of a panel of recombinase polymerase amplification assays for detection of biothreat agents A Portable Reverse Transcription Recombinase Polymerase Amplification Assay for Rapid Detection of Foot-and-Mouth Disease Virus Pitfalls of quantitative real-time reverse-transcription polymerase chain reaction Rapid Detection of HIV-1 Proviral DNA for Early Infant Diagnosis Using Recombinase Polymerase Amplification Influence of sequence mismatches on the specificity of recombinase polymerase amplification technology Emergence of a novel GII.17 norovirus-end of the GII.4 era? Incidence of and factors associated with false positives in laboratory diagnosis of norovirus infection by amplification of the RNA-dependent RNA polymerase gene A method for the rapid construction of cRNA standard curves in quantitative real-time reverse transcription polymerase chain reaction Genogroup-specific PCR primers for detection of Norwalk-like viruses Molecular Evolutionary Genetics Analysis version 6.0 M.D.M. conceived, performed, and wrote the work presented here. L.A.J. conceived, directed, and also wrote the work presented here. Supplementary information accompanies this paper at http://www.nature.com/srep