key: cord-0866540-r6nq0eyd authors: Chezganova, Evgenia; Efimova, Olga; Sakharova, Vera; Efimova, Anna; Sozinov, Sergey; Kutikhin, Anton; Ismagilov, Zinfer; Brusina, Elena title: Ventilation-Associated Particulate Matter Is a Potential Reservoir of Multidrug-Resistant Organisms in Health Facilities date: 2021-06-30 journal: Life (Basel) DOI: 10.3390/life11070639 sha: 734bcdf0e8c0c1729615a146b8031712fef3961f doc_id: 866540 cord_uid: r6nq0eyd Most healthcare-associated infections (HCAIs) develop due to the colonisation of patients and healthcare workers by multidrug-resistant organisms (MDRO). Here, we investigated whether the particulate matter from the ventilation systems (Vent-PM) of health facilities can harbour MDRO and other microbes, thereby acting as a potential reservoir of HCAIs. Dust samples collected in the ventilation grilles and adjacent air ducts underwent a detailed analysis of physicochemical properties and biodiversity. All Vent-PM samples included ultrafine PM capable of reaching the alveoli. Strikingly, >70% of Vent-PM samples were contaminated, mostly by viruses (>15%) or multidrug-resistant and biofilm-producing bacterial strains (60% and 48% of all bacteria-contaminated specimens, respectively). Total viable count at 1 m from the ventilation grilles was significantly increased after opening doors and windows, indicating an association between air flow and bacterial contamination. Both chemical and microbial compositions of Vent-PM considerably differed across surgical vs. non-surgical and intensive vs. elective care units and between health facilities located in coal and chemical districts. Reduced diversity among MDRO and increased prevalence ratio in multidrug-resistant to the total Enterococcus spp. in Vent-PM testified to the evolving antibiotic resistance. In conclusion, we suggest Vent-PM as a previously underestimated reservoir of HCAI-causing pathogens in the hospital environment. The rapid development and implementation of novel health technologies are intertwined with the growing complexities of the control for healthcare-associated infections (HCAIs). According to the recent estimates, HCAIs affect 3-15% of patients within inpatient health facilities [1, 2] and these numbers are drastically higher in intensive care units, reaching an unacceptable 30% of the patients [3] . The total annual costs of HCAIs are around USD 10 billion in the United States [4] and GBP 3 billion in the United Kingdom [5] . In addition to the significant deterioration of the quality of life and prolonging the hospital stay, HCAIs are associated with an increased risk in adverse outcome, including death [6, 7] . The burden of HCAIs is determined by multiple drug resistance (MDR), a phenomenon whereby certain bacterial strains survive at harsh hospital environment and acquire intricate mechanisms to become unresponsive to antibiotics, e.g., changes in the (3) health facilities located within the urban areas containing exclusively coal (n = 27) or chemical (n = 36) enterprises. The distribution of Vent-PM samples among the study groups is indicated in Table 1, which shows the distribution across all comparisons, and Table 2 , which demonstrates the distribution specifically across industrial districts. The entire metadata for all collected samples is represented in Table 3 . For visualisation, Vent-PM samples (n = 16 for non-surgical and n = 12 for surgical units; n = 18 for elective care and n = 10 for intensive care units; n = 11 for coal and n = 17 for chemical districts) were mounted on a double-sided adhesive conductive carbon tape on the aluminum stubs and visualised by scanning electron microscopy (JSM-6390LA, JEOL, Tokyo, Japan) at 30 kV accelerating voltage and 1 nA probe current. Elemental analysis was carried out by energy-dispersive X-ray spectroscopy (JED-2300, JEOL, Tokyo, Japan) at 133 eV spectral resolution. For each Vent-PM sample, we defined three representative quadrants and measured the average atomic percent for each element employing the ZAF correction method and then we calculated the weight percent of each element. CHNSO analysis was performed in the same Vent-PM samples (n = 28) by a catalytic oxidation of the particles at 1060 • C (Flash 2000, Thermo Fisher Scientific, Waltham, MA, USA). A particle-size distribution curve of hospital Vent-PM (n = 16 for non-surgical and n = 12 for surgical units; n = 18 for elective care and n = 10 for intensive care units; n = 11 for coal and n = 17 for chemical districts) was assessed by dynamic light scattering (Zetasizer Nano ZS, Malvern Instruments, Malvern, UK). Before the measurement, Vent-PM samples were resuspended in sterile-filtered double distilled water, ultrasonicated for 20 min to disaggregate the particles, sequentially filtered through the 1.0, 0.45, and 0.22 µm pores to separate the ultrafine PM, and then incubated at 25 • C for 20 min. All measurements were performed five times (50 runs per measurement) with the further calculation of the average distribution. Detection of the RNA belonging to group A rotaviruses (Rotavirus A), genotype II noroviruses (Norovirus genogroup II), astroviruses (Astrovirus), enteroviruses (Enterovirus), hepatitis A virus and SARS-CoV-2, as well as DNA of Shigella spp., enteroinvasive Escherichia coli, Salmonella spp., and thermophilic Campylobacter In order to investigate the bacterial diversity, all Vent-PM samples (n = 128) were seeded into the dextrose broth (M044, HiMedia Laboratories, Mumbai, India) and incubated at 37 • C for 24 h. Next, inoculates were re-seeded onto the blood agar (CM0055B, Thermo Scientific, Waltham, MA, USA), CHROMagar Candida (CA223-25, CHROMagar, Paris, France), or CHROMagar Orientation (RT413-25, CHROMagar, Paris, France) for 24 h at 37 • C. In order to obtain the pure culture, inoculates were re-seeded onto the Kligler's iron agar (O16, Research Institute for Applied Microbiology and Biotechnology, Obolensk, Russia) with the following incubation at 37 • C before colonies became clearly distinguishable. Molecular typing was conducted using the VITEK ® 2 COMPACT Microbial Detection System (BioMerieux, Marcy-l'Etoile, France). Briefly, suspension cultures with the optical density of 0.50-0.65 McFarland turbidity standards were loaded into either VITEK ® 2GN (21341, BioMerieux, Marcy-l'Etoile, France) or VITEK ® 2GP identification cards (21342, BioMerieux, Marcy-l'Etoile, France) for the detection of Gram negative and Gram positive species, respectively, according to the manufacturer's instructions. Upon 5-10 h, an automated algorithm compared the biochemical profile of the microorganisms with the reference standards in the database. Antibiotic resistance was determined in a similar manner (n = 44 Vent-PM samples) utilising VITEK ® 2 AST cards (BioMerieux, Marcy-l'Etoile, France) according to the manufacturer's instructions. The presence of biofilms at the surfaces of ventilation grilles (n = 29) and other hospital surfaces (n = 121) was examined by measuring the activity of a bacterial catalase using H 2 O 2 containing films (BFR peroxyfilm, BFR Laboratories, Moscow, Russia). Total viable count (colony-forming units per m 3 air) was quantified in 0.25 m 3 air, which was aspirated by the impactor air sampler (Flora-100, Central Research Institute of Epidemiology, Moscow, Russia) at ≈1 m distance from the ventilation grilles (n = 19) before and after opening doors and windows. Vent-PM samples were resuspended in Sabouraud dextrose broth (M033, HiMedia Laboratories, Mumbai, India), incubated for 24 h at 35 • C, then inoculated into Sabouraud dextrose agar (M063, HiMedia Laboratories, Mumbai, India) and CHROMagar Candida (CA223-25, CHROMagar, Paris, France), and finally incubated for 7 days at 35 • C. Identification of pathogenic yeasts was carried out by VITEK ® 2 YST identification cards (21343, BioMerieux, Marcy-l'Etoile, France) employing VITEK ® 2 COMPACT Microbial Detection System (BioMerieux, Marcy-l'Etoile, France). Molds were detected by a microscopic examination. Statistical analysis was carried out by GraphPad Prism 8 (GraphPad Software, San Diego, CA, USA). Descriptive data were represented by the median with interquartile range. Unpaired (independent) and paired (before-after) groups were compared by Mann-Whitney U-test and Wilcoxon matched-pairs signed rank test, respectively. P values ≤ 0.05 were defined as statistically significant. We first examined the appearance of hospital Vent-PM, revealing two main geometric patterns: globular particles (13/28 samples, 46.4%, Figure 1A ) and microscale fibres (15/28 samples, 53.6%, Figure 1B) , which, however, did not correlate with the unit specialisation (Figure 2A ), health facility location ( Figure 2B ), or bacterial ( Figure 2C ) or viral ( Figure 2D ) contamination. Measurement of particle-size distribution by means of dynamic light scattering found ultrafine PM in all samples ( Figure 3 ). No considerable differences have been documented between surgical and non-surgical units ( Figure 3A ) as well as intensive and elective care units ( Figure 3B ), yet the particle-size distribution significantly differed between Vent-PM samples collected in health facilities located within coal and chemical districts ( Figure 3C ). Accordingly, Vent-PM sampled in distinct units had almost similar mineral compositions consisting of carbon, oxygen, nitrogen, hydrogen, magnesium, sodium, aluminum, silicon, phosphorus, sulfur, chlorine, potassium, calcium, and iron. Intriguingly, higher amounts of nitrogen were detected in Vent-PM from non-surgical vs. surgical units and wards vs. operating rooms ( Figure 4A ). Vent-PM from the health facilities within the coal districts contained higher proportion of carbon, oxygen, and hydrogen but lower content of potassium than compared with those from the chemical districts ( Figure 4B ). Virus-contaminated Vent-PM had higher proportion of nitrogen but lower proportion of oxygen ( Figure 4C ). The composition of contaminated Vent-PM, however, differed between non-surgical and surgical units, as the former had higher proportions of carbon and nitrogen ( Figure 4D ). Mineral composition of Vent-PM collected in elective and intensive care units did not differ significantly (data not shown). Microbiological analyses identified the microorganisms in 90/128 (70.3%) Vent-PM samples. Bacteria, viruses and fungi were detected in 81/128 (63.3%), 20/128 (15.6%), and 12/128 (9.4%) Vent-PM samples, respectively; 16/128 (12.5%) samples were contaminated by both bacterial and viral pathogens ( Figure 5A ). Hospital Vent-PM was notable for the high microbial diversity. In particular, bacteria were represented by 23 genera ( Figure 5B ) and Gram negative microbes prevailed over Gram positive microbes (62.5 and 37.5%, respectively). Molecular typing revealed the presence of Acinetobacter baumannii, Acinetobacter haemolyticus, Acinetobacter lwoffi, Aeromonas sobria, Aeromonas salmonicida, Brevundimonas diminuta, Bordetella bronchiseptica, Campylobacter spp., Chromobacterium violaceum, Cronobacter dublinensis, Enterococcus faecium, Enterococcus faecalis, Enterococcus durans, Enterococcus gallinarum, Klebsiella pneumoniae, Kluyvera intermedia, Moraxella lacunata, Micrococcus spp., Pantoea spp., Pasteurella canis, Pasteurella testudinis, Pseudomonas aeruginosa, Pseudomonas luteola, Rhizobium radiobacter, Roseomonas gilardii, Raoultella ornithinolytica, Sphingomonas paucimobilis, Shewanella putrefaciens, Serratia plymuthica, Salmonella spp., Staphylococcus pseudintermedius, Staphylococcus hominis ssp. hominis, and Staphylococcus faecalis. Sapronotic agents were responsible for 56.2% of all bacterial diversity, with Sphingomonas paucimobilis (9.4%), Micrococcus spp. (9.4%), and Acinetobacter spp. (6.3%) being the most frequent. Around 26% of bacteria were undefined because of their metabolic dormancy in the spore form. The total viable count near (≈1 m) ventilation grilles was significantly increased after opening doors and windows (from 163 to 303 colony-forming units per m 3 air, p = 0.026, Supplementary Figure S1 ), which indicates an association between the circulation of air flow and ventilation-associated bacterial contamination. Antibiotic resistance profiling of 44 Vent-PM samples revealed that ≈60% (26/44) of them harboured MDRO ( Figure 5C ). In order to measure the bacterial evolution in the direction of antibiotic resistance, we calculated the prevalence ratio of multidrug-resistant to total Enterococcus spp. (the most frequent bacterial genus in Vent-PM) and found it ≈1.77 (38.7% to 21.9%, Figure 5C ). Taken together, with reduced diversity amongst MDRO (13 genera, Figure 5C ) as compared to the entire bacterial community in the Vent-PM (23 genera, Figure 5B ), this suggested the Vent-PM as a potential reservoir of evolving antibiotic resistance. Viral diversity was limited to the Rotavirus (56.5% of virus-contaminated samples), Norovirus (13.0%), and Betacoronavirus (30.4%) genera ( Figure 5D ). Out of 35 Vent-PM samples collected in health facilities with officially documented cases of COVID-19, seven (20.0%) contained SARS-CoV-2 RNA, indicating Vent-PM as a potential vehicle for its airborne transmission. Among the fungal species, we found molds but not pathogenic yeasts in all 12 contaminated samples. None of the identified fungi belonged to Aspergillus spp. The detailed information for each sample is summarised in Table 4 . Vent-PM from the surgical units were most frequently contaminated by bacteria (32/40 samples, 80.0%), with only a minor proportion of MDRO (7/40, 17.5%) and rare (1/40, 2.5%) contamination by viruses or fungi ( Figure 6A ). Most of these samples were contaminated by Gram negative microorganisms (88.2%), while only one-third contained Gram positive species (33.3%). In contrast, non-surgical units were less frequently contaminated (58/88 samples, 65.9%, p = 0.16) but were characterised by a significantly higher proportion of virus-infected and fungi-infected Vent-PM samples (19/88, 21.6% and 11/88, 12.5%, p = 0.004, respectively, Figure 6A ) and by the predominance of Gram negative species (53.1%) over Gram positive (46.9%). However, the prevalence of MDRO in Vent-PM did not differ between surgical and non-surgical units (7/40, 17.5% and 19/88, 21.6%, p = 0.77, Figure 6A ). Bacterial diversity in Vent-PM from non-surgical and surgical units was represented by 14 and 19 genera, respectively ( Figure 6B ). Sphingomonas spp. and Pantoea spp. prevailed in Vent-PM from surgical units (≈30% taken together), whereas Enterococcus spp. and Micrococcus spp. were responsible for >40% bacteria in Vent-PM from non-surgical units ( Figure 6B ). Vent-PM from surgical units harboured seven genera of MDRO without a clearly defined leading strain, in contradistinction to non-surgical units where Enterococcus spp. contributed to 50% of all MDRO ( Figure 6C ). Along with the prevalence ratio of multidrug-resistant to total Enterococcus spp. ≈1.81 (50.0% to 27.7%), this pointed at an ongoing evolution towards the development of a predominant antibiotic-resistant clone in non-surgical units ( Figure 6C ). Among the viruses, Rotavirus was the most frequent genus in Vent-PM (≈55% of all viruses, Figure 6D ). Regarding the comparison between intensive and elective care units, no differences in prevalence of contaminated Vent-PM samples have been revealed (32/48, 66 .7% and 58/80, 72.5%, respectively, p = 0.62, Figure 7A ). Nevertheless, Vent-PM from intensive care units showed considerably lower rates of bacterial contamination than Vent-PM collected in elective care units (24/48, 50 .0% and 58/80, 72.5%, respectively, p = 0.017) but higher frequency of fungal contamination (9/48, 18.7% vs. 3/80, 3.7%, p = 0.012) ( Figure 7A ). The ratio of Gram positive and Gram negative bacteria also differed between intensive and elective care units (61.9% Gram positive vs. 38.1% Gram negative in the former and 76.1% Gram positive vs. 23.8% Gram negative in the latter setting). Importantly, despite the lower bacterial contamination, Vent-PM from the intensive care units demonstrated higher colonisation by MDRO than samples from elective care units, albeit this did not reach statistical significance (13/48, 27.1% vs. 13/80, 16.3%, respectively, p = 0.21, Figure 7A ). Vent-PM collected in the intensive care units was featured by the preponderance of Enterococcus spp. (≈43% of all bacteria, Figure 7B ), which also composed the majority of MDRO (≈53%, Figure 7C ). Albeit Vent-PM from elective care units was populated by a variety of bacterial species (Figure 7B ), four genera contributed to almost two-thirds of MDRO (Enterococcus spp., Klebsiella spp., Sphingomonas spp. and Bordetella spp., Figure 7C ). The prevalence ratio of multidrug-resistant to total Enterococcus spp. was ≈1.24 (53.3% to 42.9%) in intensive care and ≈2.63 (25.0% to 9.5%) in elective care units ( Figure 7B,C) , indicating a higher rate of antibiotic resistance development in the latter. Most probably due to the COVID-19 pandemic, Betacoronavirus was the main viral genus in Vent-PM from intensive care units (≈80% of all viruses), while Rotavirus was the leading taxon in the samples from elective care units (70%) ( Figure 7D ). Strikingly, Vent-PM was contaminated in 88.9% (24/27) of health facilities located in coal districts; bacterial species were detected in all of these samples, while viruses and fungi were less often encountered (4/27, 11.1%, Figure 8A ). Vent-PM samples from 36 health facilities located in chemical districts were contaminated in only 21 (58.3%) cases (p = 0.017), harbouring bacteria in 18/36 (50.0%) and viruses in 9/36 (25.0%) specimens ( Figure 8A ). The prevalence of MDRO in health facilities did not differ between coal and chemical districts (p = 0.90, Figure 8A ). Bacterial diversity in Vent-PM from coal district-associated health facilities was also higher whereas ≈46% of microbes found in Vent-PM from health facilities located in chemical districts were related to Enterococcus spp. and Micrococcus spp. (Figure 8B ). In both locations of health facilities, the diversity of MDRO was almost twofold lower (7/8 genera) as compared to the total bacterial diversity (15/14 genera) ( Figure 8B,C) . We documented a predominance of multidrug-resistant Enterococcus spp. in Vent-PM from health facilities located in chemical districts, whereas none of the multidrug-resistant strains prevailed in coal districts ( Figure 8C ). Similar to the non-surgical and elective care units, the prevalence ratio of multidrug-resistant to total Enterococcus spp. in health facilities located in chemical districts was ≈1.75 (57.1% to 32.6%), which suggests the evolution towards antibiotic resistance ( Figure 8B ,C). The most of viral strains belonged to the Rotavirus genus ( Figure 8D ). Employing the peroxide-based biofilm detection (where the bubbles appearing at the surface as a result of the interaction between the peroxide detector and bacterial catalase indicate a positive reaction), we revealed biofilms at 14/29 (48.3%) ventilation grilles and 11/121 (9.1%) other hospital surfaces (p = 0.0001, Figure 9 ). Analysis of Vent-PM from the indicated 14 biofilm-positive ventilation grilles found a high rate (6/14, 42 .9%) of MDRO detection, suggesting Vent-PM as a potential reservoir for biofilm-producing strains, which are particularly hazardous in terms of multidrug resistance. Among the detected MDRO were Roseomonas gelardii, Serratia plymutica, Sphingomonas pacimobilis, Enterococcus faecium, and Klebsiella pneumoniae (2). Hospital environment represents a unique ecosystem with a rapidly ongoing molecular evolution, which favors the selection and spread of MDRO [52] [53] [54] that is an immense burden for both healthcare and economy responsible for around 700,000 annual deaths worldwide [55] . If not counteracted by antimicrobial stewardship, bacterial evolution might eventually result in the formation of a "superbug" resistance to the routine antibiotics, spreading across the distinct habitats within the health facilities, superseding other strains and causing HCAIs [56] [57] [58] [59] . In the majority of cases, such MDRO evolve on various hospital surfaces because, in spite of their availability for regular cleaning and disinfection [7, 60, 61] , these measures have limited efficiency and significantly depends on the compliance of medical staff [62, 63] . Furthermore, recent studies indicated the potential importance of distant sources in harbouring MDRO [64] . Ventilation grilles and adjacent air ducts, which in many cases are rarely cleaned and are often hard-to-reach for the proper disinfection, have been suggested as remote shelters for MDRO [49, 54] , yet the respective evidence is merely anecdotal [65] . However, as PM is well-known for carrying pathogenic bacteria [38, 39] and viruses [40, 41] , we hypothesised that the dust from the hospital ventilation systems might represent a potential vehicle for multiple MDRO. As distinct hospital units have different compositions of microbial populations [66, 67] and surgical site infections account for the significant proportion of HCAIs [13] , we compared surgical and non-surgical units in relation to the physicochemical and microbial profile of Vent-PM. Furthermore, we made a similar comparison between intensive and elective care units by taking into account a substantially higher prevalence of HCAIs in the former [3] . With respect to the earlier reports on the correlations between outdoor and indoor air pollution [68, 69] , we investigated whether the features of ambient air pollution are associated with the respective changes in hospital Vent-PM. We found that hospital Vent-PM is heterogeneous and largely defined by both outdoor and indoor environment, as health facilities located within coal and chemical districts as well as non-surgical and surgical units were characterised by distinct elemental composition of Vent-PM. The presence of ultrafine PM in all Vent-PM samples confirmed the possibility of its circulation in the hospital air and penetration into the patient alveoli. Furthermore, Vent-PM was notable for the high rate of microbial (>70%) and particularly bacterial (>63%) contamination. Analysis of bacterial diversity indicated 23 genera associated with Vent-PM and a remarkable abundance of MDRO (≈60% of bacteria-contaminated samples), which generally had reduced diversity as calculated by multidrug-resistant to total Enterococcus spp. ratio. Vent-PM from the surgical units showed higher bacterial but lower viral and fungal contamination, although without a trend to the increase in MDRO proportion. Conversely, Vent-PM collected in intensive care units was less frequently colonised by bacteria but more often contained fungi in comparison with elective care units, also without statistically significant differences regarding MDRO. As pathogenic yeasts (including Candida spp.) have not been detected, fungal diversity was limited to molds. Unexpectedly, microscopic examination also did not reveal Aspergillus spp. in Vent-PM samples. Possible explanations include extremely cold winters in Siberia (−45 • C in January) in combination with low air humidity (≈30%) in healthcare facilities due to the central heating system working ≈8 months annually. The contamination of Vent-PM from intensive care units by Betacoronavirus RNA demonstrated the dependence of Vent-PM microbial composition on patient setting, as some of these units specialised on the treatment of severe COVID-19. Moreover, it suggested a plausible role of Vent-PM in Betacoronavirus transmission, as SARS-CoV-2 can be detected even at ≈4 m from the patients [70] [71] [72] . In contrast, Vent-PM samples from elective care units were devoid of Betacoronavirus RNA, instead being contaminated with Rotavirus and Norovirus. In addition to the treatment specialisation, the microbial composition of Vent-PM was significantly impacted by the environment, as Vent-PM sampled in the health facilities from coal districts was 1.5-fold more often contaminated than Vent-PM from medical organisations located in chemical districts. Taken together, our findings suggest dynamic interactions between the environment, patients, and Vent-PM acting as a harbourer for MDRO. Reduced biodiversity among MDRO compared to the total bacterial community and elevated prevalence ratio of multidrug-resistant to total Enterococcus spp. in Vent-PM testified to the evolving antibiotic resistance in the hospital ventilation. Hospital surfaces are well-known for sheltering microbial pathogens by supplying them with a physical scaffold for the formation of biofilms, which is a self-produced molecular barrier protecting the microorganisms from cleaning agents and disinfectants and therefore creating a putative reservoir of antimicrobial resistance [23] . As the profile of microorganisms on the hospital surfaces is reminiscent of those circulating in ambient air [24] , we assessed the biofilm-forming ability of the bacteria settling the ventilation grilles as compared with those colonising other hospital surfaces. We found a notably increased prevalence in biofilms on ventilation grilles as compared with other hospital surfaces. A substantial proportion of these biofilms (≈43%) harboured MDRO. Probably, irregular or inefficient cleaning of ventilation grilles promoted the survival of biofilm-producing and often multidrug-resistant bacteria, eventually resulting in the formation of biofilms on the ventilation-associated surfaces and also Vent-PM. These results underscore the potential importance of Vent-PM as a reservoir of multidrug resistance and underlines its relevance to the development of HCAIs. Our results highlight the significance of Vent-PM for sheltering pathogenic microbes and indicate ventilation grilles together with the adjoining ductwork as a habitat for MDRO. The regular cleaning and disinfection of air ducts, possibly by the modern notouch devices [60, 73] , might therefore contribute to the prevention of HCAIs. However, an impact of antimicrobials on the molecular evolution of micro-organisms colonising Vent-PM is unclear, particularly in relation to the bacteria emerging from the surfaces available for regular cleaning, which are frequently exposed to disinfectants. Further studies in this direction, including those employing next-generation sequencing, are required to better uncover the diversity and survivability of MDRO and other microbes in Vent-PM. Relatively high frequencies of viral contamination of Vent-PM points at the respective mechanism of airborne disease transmission, although the relative impact of bacterial and viral contamination of Vent-PM on the development of HCAIs has yet to be defined. However, viral transmission through Vent-PM should not be neglected in light of the COVID-19 pandemic. PM from the hospital ventilation systems harbour a wide, patient-dependent, and environment-dependent spectrum of bacterial and viral pathogens and may be considered as a reservoir for biofilm-producing MDRO, which is a main culprit of HCAIs. Supplementary Materials: The following are available online at https://www.mdpi.com/article/ 10.3390/life11070639/s1, Figure S1 : Total viable count in the hospital air before and after opening doors and windows. Data Availability Statement: The datasets generated and/or analysed during the current study are available from the corresponding author upon reasonable request. Implementation research for the prevention of antimicrobial resistance and healthcare-associated infections; 2017 Geneva infection prevention and control (IPC)-think tank (part 1) National Contact Points for the ECDC pilot point prevalence survey; Hospital Contact Points for the ECDC pilot point prevalence survey. The European Centre for Disease Prevention and Control (ECDC) pilot point prevalence survey of healthcare-associated infections and antimicrobial use Emerging Infections Program Hospital Prevalence Survey Team. Changes in Prevalence of Health Care-Associated Infections Health care-associated infections: A meta-analysis of costs and financial impact on the US health care system Modelling the annual NHS costs and outcomes attributable to healthcareassociated infections in England Impact of multi-drug resistant bacteria on economic and clinical outcomes of healthcare-associated infections in adults: Systematic review and meta-analysis Practical recommendations for routine cleaning and disinfection procedures in healthcare institutions: A narrative review Multidrug resistance in bacteria Molecular mechanisms of antibiotic resistance Antibiotic Resistance Mechanisms in Bacteria: Relationships between Resistance Determinants of Antibiotic Producers, Environmental Bacteria, and Clinical Pathogens Antimicrobial Resistance in Bacteria: Mechanisms, Evolution, and Persistence Antimicrobial-resistant pathogens associated with adult healthcare-associated infections: Summary of data reported to the National Healthcare Safety Network Antimicrobial-resistant pathogens associated with pediatric healthcare-associated infections: Summary of data reported to the National Healthcare Safety Network Update of contemporary antimicrobial resistance rates across China: Reference testing results for 12 medical centers Presence of biofilm containing viable multiresistant organisms despite terminal cleaning on clinical surfaces in an intensive care unit Bacterial contamination of inanimate surfaces and equipment in the intensive care unit Rate of contamination of hospital privacy curtains on a burns and plastic surgery ward: A cross-sectional study Bacterial contamination of frequently touched objects in a tertiary care hospital of Pokhara, Nepal: How safe are our hands? Characterization of microbial community composition, antimicrobial resistance and biofilm on intensive care surfaces Biofilm contamination of high-touched surfaces in intensive care units: Epidemiology and potential impacts Bacterial contamination of neonatal intensive care units: How safe are the neonates? Beware biofilm! Dry biofilms containing bacterial pathogens on multiple healthcare surfaces; a multi-centre study Is there an association between airborne and surface microbes in the critical care environment? Factors contributing to airborne particle dispersal in the operating room Sources of contamination in the operating room: A fluorescent particle powder study Impact of multicenter unified enhanced environmental cleaning and disinfection measures on nosocomial infections among patients in intensive care units Indoor hospital air and the impact of ventilation on bioaerosols: A systematic review Ambient particulate matter pollution and adult hospital admissions for pneumonia in urban China: A national time series analysis for Short-term exposure to air pollution and hospital admission for pneumonia: A systematic review and meta-analysis Short-term association between ambient air pollution and pneumonia in children: A systematic review and meta-analysis of time-series and case-crossover studies Air pollution and respiratory infections during early childhood: An analysis of 10 European birth cohorts within the ESCAPE Project Risk factors for mortality from acute lower respiratory infections (ALRI) in children under five years of age in low and middle-income countries: A systematic review and meta-analysis of observational studies Roles of sunlight and natural ventilation for controlling infection: Historical and current perspectives Effects of indoor environmental parameters related to building heating, ventilation, and air conditioning systems on patients' medical outcomes: A review of scientific research on hospital buildings Reducing Aerosol-Related Risk of Transmission in the Era of COVID-19: An Interim Guidance Endorsed by the International Society of Aerosols in Medicine Spatiotemporal variations in the association between particulate matter and airborne bacteria based on the size-resolved respiratory tract deposition in concentrated layer feeding operations Bacteria and Antibiotic Resistance Genes (ARGs) in PM2.5 from China: Implications for Human Exposure SARS-Cov-2RNA found on particulate matter of Bergamo in Northern Italy: First evidence 5)) as a potential SARS-CoV-2 carrier Effects on health of air pollution: A narrative review Short-term Exposure to Ambient Fine Particulate Matter Increases Hospitalizations and Mortality in COPD: A Systematic Review and Meta-analysis Outdoor Air Pollution and COPD-Related Emergency Department Visits, Hospital Admissions, and Mortality: A Meta-Analysis Impact of long-term exposure to ambient air pollution on the incidence of chronic obstructive pulmonary disease: A systematic review and meta-analysis Association between air pollution and general outpatient clinic consultations for upper respiratory tract infections in Hong Kong Acute effects of ambient air pollution on clinic visits of college students for upper respiratory tract infection in Wuhan Controlling hospital-acquired infection: Focus on the role of the environment and new technologies for decontamination Environmental contamination and hospital-acquired infection: Factors that are easily overlooked A Comparison of the Health Effects of Ambient Particulate Matter Air Pollution from Five Emission Sources Particulate matter components, sources, and health: Systematic approaches to testing effects Microbiology of the built environment Hospital-associated microbiota and implications for nosocomial infections Rethinking sterile: The hospital microbiome The challenge of antimicrobial resistance: What economics can contribute Next-generation approaches to understand and combat the antibiotic resistome Emergence and Spread of Epidemic Multidrug-Resistant Pseudomonas aeruginosa Emergence of dominant multidrug-resistant bacterial clades: Lessons from history and whole-genome sequencing The emergence, maintenance, and demise of diversity in a spatially variable antibiotic regime Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals Environmental cleaning and disinfection of patient areas Evaluation of the Cleaning Procedure Efficacy in Prevention of Nosocomial Infections in Healthcare Facilities Using Cultural Method Associated with High Sensitivity Luminometer for Assessment of the Overall and Multidrug-Resistant Organism Bioburden on Environmental Surfaces in Healthcare Facilities Cross-sectional point prevalence survey to study the environmental contamination of nosocomial pathogens in intensive care units under real-life conditions Ventilation grilles as a potential source of methicillinresistant Staphylococcus aureus causing an outbreak in an orthopaedic ward at a district general hospital Exploring bacterial diversity in hospital environments by GS-FLX Titanium pyrosequencing One year cross-sectional study in adult and neonatal intensive care units reveals the bacterial and antimicrobial resistance genes profiles in patients and hospital surfaces Estimating mortality derived from indoor exposure to particles of outdoor origin Characterizing the Indoor-Outdoor Relationship of Fine Particulate Matter in Non-Heating Season for Urban Residences in Beijing Aerosol and Surface Distribution of Severe Acute Respiratory Syndrome Coronavirus 2 in Hospital Wards Novel Coronavirus Outbreak Research Team. Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients Characterization of hospital airborne SARS-CoV-2 No touch' technologies for environmental decontamination: Focus on ultraviolet devices and hydrogen peroxide systems The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript or in the decision to publish the results.