key: cord-0864785-apik2nvq authors: Singh, Harpreet; Sharma, Poonam; Kapoor, Pranav; Maurya, Raj Kumar title: Virucidal mouth rinses for patients during the coronavirus disease 2019 outbreak date: 2021-05-28 journal: Am J Orthod Dentofacial Orthop DOI: 10.1016/j.ajodo.2020.12.011 sha: 90e5a93ef7bbaa4da9e40aaf1fd0835faab7164b doc_id: 864785 cord_uid: apik2nvq nan Authors' response W e appreciate the interest in our article and the opportunity to respond to the opinion expressed in the letter to the editor. While we understand the point regarding the material used in fabricating the clear aligner design in our study, we respectfully maintain that the title reflects the content of the text of the article. We offer below the rationale for our position. As detailed in the letter and our article, the resin applied in our study (Dental LT Clear Resin; Formlabs, Inc, Somerville, Mass) is marketed as a Class IIa biocompatible resin for direct fabrication of long-term orthodontic appliances. The manufacturer states on the material data sheet that the resin is "ideal for dental splints, retainers, and similar applications." 1 Given the similarities in the geometry of Essix retainers and passive clear aligners, we selected the Dental LT Clear Resin for use in our study to investigate the effects of print orientation and duration of ultraviolet light curing on the dimensional accuracy of a 3-dimensionally (3D) printed passive clear aligner design. While the geometry of the passive clear aligner design investigated in our study presents similarities with the geometry of an Essix retainer, it is distinct from the geometry of an occlusal guard or splint. Accordingly, we respectfully disagree with the suggestion offered in the letter that the title of the article should reflect investigation of an "occlusal guard or hard splint." To our knowledge, no materials were marketed for direct 3D printing of clear aligners at the time of the initial submission of our article in September 2019. A survey of the literature since the initial submission of our manuscript revealed that the same resin (Dental LT) and model of 3D printer (Form 2; Formlabs, Inc, Somerville, Mass) applied in our study were used to fabricate "3D printed clear aligners" in an article published in the American Journal of Orthodontics and Dentofacial Orthopedics in November 2019. 2 Although the precedent was established in the literature for investigation of the fabrication of 3D-printed "clear aligners" with the material in question (Dental LT), our article acknowledges the material as a limitation of the study and states that "the material tested in this study is cleared for long-term intraoral use, but it is not currently marketed specifically for clear aligner fabrication." We agree with the point offered in the letter that the properties of materials for direct fabrication of clear aligners must satisfy a variety of requirements in order to be suitable for the clinical application. To this end, our article states that, in addition to dimensional accuracy and mechanical properties, "factors beyond the scope of this study, such as color, leachables, aging, and durability with wear, are also important considerations for future investigation in the fabrication of aligners directly by 3D printing." Indeed, a recent guest editorial appearing in the American Journal of Orthodontics and Dentofacial Orthopedics echoes the need to characterize fully the properties of resins intended for direct fabrication of orthodontic appliances via 3D printing. 3 We offer that our article provides some early insight into properties and challenges associated with direct fabrication of clear aligner designs through 3D printing of a specific material marketed for long-term orthodontic applications, and it underscores the need for additional research "as resins marketed for clear aligner fabrication emerge on the market." The author recommended using 0.12%-0.20% chlorhexidine gluconate (CHX) and referenced studies by Ge et al 1 and Marui et al. 2 However, the systematic review by Marui et al 2 showed the efficacy of CHX against the bacterial load in dental aerosol and not the viral particles. We critically analyzed the in vitro study by Wood and Payne, 3 which also showed CHX was ineffective in the inactivation of enveloped human coronavirus. A recent review by O'Donnell et al 4 reported lower virucidal activity of CHX toward coronaviruses and recommended exploring the option of using a combination of CHX with alcohol for reducing oral bioburden over longer times. In contrast, povidone iodine (PVP-I), a broadspectrum oxidizing antimicrobial widely used for 60 years and with a well-established safety profile, has been shown to be an effective virucide in vitro against similar severe acute respiratory syndrome coronavirus (SARS-CoV-2) and Middle East Respiratory Syndrome viruses. 5, 6 In vitro viricidal efficacy of 0.5% PVP-I oral rinse after 15 seconds contact time, and 1.0% (w/v) PVP-I oral rinse, and 0.45% (w/v) PVP-I throat spray after 30 seconds has also been recently demonstrated by Bidra et al 7 and Anderson et al, 8 respectively. Preliminary in vivo efficacy of 1-minute rinse with 1% PVP-I with effects lasting for up to 3 hours in real-time clinical settings involving a limited number of patients have also been recently documented. 9 However, considering the possible confounders, including viral load and the patient's immune response, the authors recommended further clinical trials to confirm its efficacy. A recent unpublished large-scale systematic review with network meta-analysis 10 involving aerosol mitigation intervention processes reported 0.2%-1% PVP-I or 1% hydrogen peroxide as an effective substitute for oxidation-prone vulnerable viruses such as SARS-CoV-2. The use of PVP-I is favorable for its gradual non-PVP-bound free iodine release, thereby minimizing toxicity, and the resultant viral inactivation arising from its oxidative effect and lipid shell membrane destruction causes irreversible damage to the pathogen. With no clinical studies supporting the virucidal effects of CHX against SARS-CoV-2, and in light of the recently emerging evidence demonstrating the in vitro and in vivo virucidal efficacy of PVP-I, it seems justifiable to recommend the innocuous use of PVP-I as a viable alternative for interrupting transmission of SARS-CoV-2. The recommendations of Kirk-Bayley et al 11 regarding the use of 9 mL of 0.5% PVP-I as a mouthwash both for the patient and for the clinical staff should be repeated every 2-3 hours, up to 4 times a day. The authors recommend distributing the mouthwash throughout the oral cavity for 30 seconds, followed by gentle gargling at the back of the throat for another 30 seconds before spitting out. On the basis of the assumption that at least 1 mL of the solution will be retained (based on self-testing using high-accuracy scales, subtracting salivary production) and absorbed, the maximum total dose of 0.55 mg of iodine is delivered. In the case that a nasal pump atomizing device is used, the steps involve the use of 7 sprays aimed in different directions, followed by licking around the inside of the oral cavity, thereby yielding 0.54 mg of iodine (0.14 mL per actuation for most commercially available nasal atomizers at 0.077 mg iodine per actuation). 11 Furthermore, the authors recommend the intranasal application of 0.28-0.3 mL of 0.5% PVP-I solution into each nostril (using 2 sprays for an average atomizing device or by using a syringe), for patients and also for health care workers this should be repeated every 2-3 hours, up to 4 times a day. The effectively delivered total dose of 0.33 mg of iodine may minimize the bioaerosols from nasal cavities and nasopharynx. For maximizing coverage of the nasal cavity and nasopharynx during the atomization/instillation of the nasal spray, it has been advised to occlude the contralateral nostril and keep the mouth closed. Harpreet Singh Poonam Sharma Pranav Kapoor Raj Kumar Maurya Delhi, India Available at: https:// dental-media.formlabs.com/datasheets/Dental_LT_Clear_Technical. pdf Mechanical and geometric properties of thermoformed and 3D printed clear dental aligners Three-dimensional printing and in-house appliance fabrication: between innovation and stepping into the unknown Possible aerosol transmission of COVID-19 and special precautions in dentistry Efficacy of preprocedural mouthrinses in the reduction of microorganisms in aerosol: a systematic review The action of three antiseptics/disinfectants against enveloped and non-enveloped viruses Potential role of oral rinses targeting the viral lipid envelope in SARS-CoV-2 infection In vitro bactericidal and virucidal efficacy of povidone-iodine gargle/ mouthwash against respiratory and oral tract pathogens Inactivation of SARS coronavirus by means of povidone-iodine, physical conditions and chemical reagents Rapid in-vitro inactivation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using povidone-iodine oral antiseptic rinse Povidone-iodine demonstrates rapid in vitro virucidal activity against SARS-CoV-2, the virus causing COVID-19 disease Is povidone iodine mouthwash effective against SARS-CoV-2? First in vivo tests Interventions to reduce aerosolized microbes in dental practice: a systematic review with network meta-analysis of randomized controlled trials The use of povidone iodine nasal spray and mouthwash during the current COVID-19 pandemic may reduce cross infection and protect healthcare workers Effects of mechanical properties of lingual lever arm on the displacement pattern of anterior segment: a finite element analysis The use of finite element analysis in dentistry and orthodontics: critical points for model development and interpreting results Effective en-masse retraction in lingual orthodontics W e read an article published online in December that analyzed stress distribution during lingual orthodontic treatment (Kushwah A, Kumar M, Goyal M, Premsagar S, Rani S, Sharma S. Analysis of stress distribution in lingual orthodontics system for effective en-masse retraction using various combinations of lever arm and mini-implants: a finite element method study. Am J Orthod Dentofacial Orthop 2020; 158:e161-72). The authors provided an exhaustive analysis of enmasse retraction of maxillary anterior teeth using lingual orthodontics and different lengths of lever arms and different sites of mini-implants in a finite element model. However, we have some queries regarding the investigation; we would be thankful to the authors if they could apprise us regarding them.The authors write that there is a greater loss of torque of the maxillary incisors during retraction in lingual orthodontics; why was an undersized 0.016 3 0.022-in stainless steel wire employed in an 0.018-in slot in the finite element model analysis, in place of 0.017 or 0.018-in stainless steel wire? Furthermore, they cite an article by Jang et al 1 in the Discussion section, describing the wire stiffness as an important parameter for predictable tooth movement in anterior retraction by lingual orthodontics.The article mentions discretization because of the presence of a finite number of elements and nodes. However, this geometry needs to be verified using a mesh convergence test to assess for discretization errors to demonstrate that a simulation asymptotically converges to a finite value 2 ; one finds no mention in the manuscript.How many layers were used for modeling the periodontal ligament (PDL)? Recent methodology demonstrates that a single layer (tetrahedral) mesh through the PDL thickness cannot capture the variation in the stresses inside the PDL; a minimum of 3 layers are required for accurate modeling. 2 The simulations are showing extrusion of the central and lateral incisors and no extrusion of the canines (in spite of an intrusive vector of retracting forces); these results would require further elaboration, especially when there is no connection with the posterior segment.The use of a first premolar extraction model in lingual orthodontics also requires further elaboration, as clinically, a second premolar extraction may be employed owing to greater sagittal anchorage offered by the use of lingual mechanics.Finally, the authors state the use of segmental mechanics in their modeling; however, the present study has 2 different sections of archwire in the anterior and posterior teeth, which does not demonstrate segmental arch mechanics.Karan Authors' response W e have given the best effort to provide the following explanations. We emphasize the fact that there is a greater loss of torque of maxillary incisors during retraction in lingual orthodontics; therefore, a rectangular wire is used for retraction in lingual orthodontics. An 0.017 or 0.018in stainless steel round wire would result in greater torque loss of the anterior teeth. Furthermore, as stated by Romano, 1 0.016 3 0.022-in stainless steel wire is recommended in lingual orthodontics.