key: cord-0864701-n4fga8ze authors: Wezgowiec, Joanna; Wieczynska, Anna; Wieckiewicz, Mieszko; Czarny, Anna; Malysa, Andrzej; Seweryn, Piotr; Zietek, Marek; Paradowska-Stolarz, Anna title: Evaluation of Antimicrobial Efficacy of UVC Radiation, Gaseous Ozone, and Liquid Chemicals Used for Disinfection of Silicone Dental Impression Materials date: 2022-03-31 journal: Materials (Basel) DOI: 10.3390/ma15072553 sha: 4f2681f22159815f0dbc51dfe21a86f4511c384b doc_id: 864701 cord_uid: n4fga8ze Effective disinfection of dental impressions is an indispensable requirement for the safety of dental personnel and patients. The ideal method should be not only effective but also convenient, cheap, and environmentally friendly. This study aimed to reliably evaluate the efficacy of ultraviolet C (UVC) radiation, gaseous ozone, and commercial liquid chemicals used for silicone dental impressions disinfection. These methods were applied to two types of elastomeric impression materials: condensation silicones and addition silicones of various consistency (putty, medium, and light). The antimicrobial effectiveness against Pseudomonas aeruginosa, Staphylococcus aureus, and Candida albicans was evaluated in vitro by counting colony-forming units (CFU) on the surface of samples. The one-way ANOVA with a Tukey HSD test or the Kruskal–Wallis with a Dunn’s test was performed. The results obtained revealed the efficacy of the proposed methods for disinfection of both C-silicones and A-silicones in most of the studied groups. Only one material (Panasil initial contact Light) was not effectively disinfected after UVC irradiation or ozone application. In conclusion, the potential of each disinfection method should be evaluated separately for each material. Moreover, in further research, the possible influence of the proposed methods on the physical properties of the impression materials should be thoroughly investigated. Dental impressions, which are used to create a negative form of the human dentition-teeth, hard and soft oral tissues-are a crucial prerequisite for the successful manufacturing of different types of oral appliances. Based on the dental impressions, three-dimensional replicas of intraoral situation are created in order to serve as working analogs used for the final work manufacturing [1] . A high-quality dental impression provides the technician with the possibility of fabricating a more precise dental prosthesis (e.g., crowns, bridges, partial or full dentures) or orthodontic splints and appliances, designed and manufactured individually to exactly match the oral conditions of each patient. Today, traditional physical impressions are increasingly replaced by digital intraoral scans, but scanners are still very and may significantly affect even such insusceptible impression material [25, 26] . For these reasons, a detailed investigation of the potential of novel techniques of disinfection, other than spraying and immersion, is still highly recommended. In particular, UVC radiation and ozone, despite few previous research reporting usefulness of these methods for dental impressions disinfection, are still not gold standard techniques [13, [16] [17] [18] [19] . Apart from their application for surface disinfection, both these methods have the potential as a support for the treatment of endodontic infections and inflammation in root canals [27, 28] . Hence, their effects on various types of dental silicones are an important, current scientific topic still requiring investigation. This study aims to reliably evaluate the efficacy of ultraviolet C (UVC) radiation, gaseous ozone, and common chemical disinfectants (commercial spray and solution) applied to silicone dental impression materials. For this purpose, the effects of these methods of disinfection are compared for two types of elastomeric impression materials: condensation silicones (C-silicones) and addition silicones (A-silicones), contaminated with Gram-positive Staphylococcus aureus (S. aureus), Gram-negative Pseudomonas aeruginosa (P. aeruginosa), and the Candida albicans (C. albicans) fungus. The dental impression materials selected for the study are listed in Table 1 . They included two condensation silicones (C-silicones) and three addition silicones (A-silicones, Polyvinyl siloxanes) of different consistency (putty, medium, and light). The preparation of the samples directly followed the manufacturer's instructions and PN-EN ISO 4823:2015 [29] . After mixing, the materials were put into a metal mold to form disc-shaped samples with a 30 mm diameter and 6 mm height. Then, they were put in distilled water and placed in the incubator (CLN 15 Smart, POL-EKO-APARATURA, Wodzislaw Slaski, Poland) at 35 • C for the time defined by the manufacturer as the time in the oral cavity. After this conditioning, the samples were removed from the metal mold, rinsed with distilled water, air dried, and sterilized with UVC radiation (UV-C Blue, Activeshop, Wroclaw, Poland) for 50 min to avoid accidental contamination that could interfere with the microbiological test results. After preparation, one surface of each sample was inoculated with a mixture of three microbial strains: P. aeruginosa ATCC 27853, S. aureus ATCC 6538, and C. albicans ATCC 10231 (ATCC, Manassas, VA, USA). The selection of strains was based on PN-EN 13727+A2:2015-12 [30] and PN-EN 13624:2013-12 [31] . The inocula were prepared to match the turbidity of the 0.5 McFarland standard dilutions (1.5 × 10 8 CFU/mL) by transferring 1-2 colonies to the proper medium. A McFarland densitometer (DEN-1, BIOSAN, Jozefow, Poland) was used to control the density of the preculture and the final inoculum. Bacterial strains (P. aeruginosa and S. aureus) were cultured in Tryptic Soy Broth (TSB) medium (BTL, Lodz, Poland) at 35-37 • C for 18-24 h. C. albicans were grown on Sabouraud Dextrose Agar supplemented with 4% glucose (BTL, Lodz, Poland) at 28 • C for 48 h. The strains were then mixed, and the final inocula were prepared according to the ECS guidelines [32] . In the next step, impression material samples (n = 5 for each of 5 materials) were placed in separate Petri dishes and incubated in a mixed inoculum suspension at 37 • C for 30 min. Afterward, each sample was rinsed with 10 mL of water and subjected to the selected method of disinfection. A description of four methods applied for disinfection of samples (UVC, gaseous ozone, commercial spray, and solution) is included in Table 2 . Methods typically intended for dental impression disinfection (solution and spray) were used following the manufacturer's instructions. UVC radiation was performed using an exposure time of 40 min, according to the recommendation of the UVC lamp manufacturer. The ozone treatment was performed in a box with a volume of 8 L. First, ozone was generated for 9 min using an Ozox Professional G168 generator (MediaSklep24, Bojszowy, Poland) and pressed into the box to achieve a concentration of 15 ppm ozone. The samples were then placed in the box for 10 min under a further constant flow of ozone with a flow rate of 800 mg/h. A positive, non-disinfected control was prepared for each of the studied materials. In order to validate the effectiveness of the method of washing away the adhered microorganisms from the surface of inoculated impression materials, the presence of microorganisms was assessed using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) metabolic assay, following the manufacturer's protocol [33] . This assay is based on the ability of mitochondrial dehydrogenase in viable cells to cleave yellow MTT to violet formazan. After disinfection, the impressions were washed with water and placed in Petri dishes. Then, 200 µL of 5 mg/mL MTT (Sigma-Aldrich, St. Louis, MO, USA) solution was applied to each impression and incubated for 4 h at 37 • C. Subsequently, 200 µL of dimethyl sulfoxide (DMSO, Sigma-Aldrich, St. Louis, MO, USA) was added to each sample for 20 min to solubilize the formazan crystals. The amount of formazan dye produced correlates directly with the number of viable bacteria/fungi on the surface of the impression material. To assess the efficacy of the selected disinfection methods, the residual microbial contamination of the impression materials was evaluated. After disinfection, the samples were rinsed with water, immersed in 10 mL of sterile phosphate-buffered saline (PBS, Hirszfeld Institute of Immunology and Experimental Therapy, Polish Academy of Sciences, Wroclaw, Poland), and vigorously shaken using IKA MS3 Basic Vortex (IKA, Staufen, Germany) for 3 min. Then, 1:10 and 1:100 serial dilutions of microorganisms in the PBS were plated on Mueller-Hinton 2 LAB-AGAR™ (MHA, BTL, Lodz, Poland) and Sabouraud Dextrose Agar (BTL, Lodz, Poland) and incubated at 37 • C for 24-48 h (for bacteria) or at 28 • C for 48-72 h (for C. albicans) in order to recover contaminating microorganisms. Finally, the plates were inspected for the presence of colony-forming units (CFU) of the selected strains. The data were transformed into a logarithmic scale in order to be presented as log 10 CFU/mL. Statistical analysis of the obtained results was performed using GraphPad Prism 9.1.2. software (GraphPad Software, San Diego, CA, USA). All measurements were performed for the total n ≥ 15 for each group. The results were expressed as mean ± standard deviation. The parametric one-way ANOVA with a post hoc Tukey HSD test or the nonparametric Kruskal-Wallis with a post hoc Dunn's test was applied to investigate differences between the studied methods of disinfection and non-disinfected control. Differences between groups were considered statistically significant with p < 0.05. The results of the MTT assay confirmed the effectiveness of the applied method of washing away cells adhered to the contaminated samples by immersion with PBS and vortexing ( Figure 1 ). Before washing away, the presence of viable cells was demonstrated on the surface of all the studied materials as a dark blue coloration. After immersion in PBS and vortexing, detachment of the cells previously adhered on the surface of dental materials was Before washing away, the presence of viable cells was demonstrated on the surface of all the studied materials as a dark blue coloration. After immersion in PBS and vortexing, detachment of the cells previously adhered on the surface of dental materials was reached, enabling seeding of cells in the Petri dish and further processing of the experiments. The photos of the samples after washing present the original colors of the samples, confirming the lack of cells adhered to their surfaces ( Figure 1 ). Comparison of the efficacy of different methods of disinfection (UVC, gaseous ozone, solution, and spray) applied to dental impression materials was the main objective of this study. To investigate the general effect of disinfection on impression materials regardless of the type of material, the results obtained for all materials were analyzed together. The results presented in Figure 2 demonstrate that microbial growth on the surfaces of materials contaminated with the pathogens studied (S. aureus, P. aeruginosa, and C. albicans) was significantly reduced after each type of disinfection compared to the non-disinfected control material (p < 0.0001). For a more detailed investigation, the analysis of microbial growth on the surfaces of particular dental impression materials (analyzed individually), disinfected with UVC radiation, gaseous ozone, Zeta 7 solution, and Zeta 7 spray after contamination with S. aureus, P. aeruginosa, and C. albicans was performed. The results obtained are presented in Figure 3 (for C-silicones: Zetaplus and Oranwash L) and in Figure 4 (for A-silicones: Panasil Putty Soft, Panasil monophase Medium, and Panasil initial contact Light). The summary of the results (means, medians, standard deviations) is also listed in Table A1 . The results of the statistical analysis of the significance of the observed effects are listed in Table 3 . Effect of four methods (UVC, ozone, solution, and spray) used for the disinfection of all the studied materials (regardless of the type of material) contaminated with oral pathogens (S. aureus, P. aeruginosa, and C. albicans); the control material was contaminated but not disinfected; **** p < 0.0001 for all comparisons between the study (disinfected) groups and the control (non-disinfected) group. S. aureus-Staphylococcus aureus; P. aeruginosa-Pseudomonas aeruginosa; C. albicans-Candida albicans; UVC-ultraviolet C. For a more detailed investigation, the analysis of microbial growth on the surfaces of particular dental impression materials (analyzed individually), disinfected with UVC radiation, gaseous ozone, Zeta 7 solution, and Zeta 7 spray after contamination with S. aureus, P. aeruginosa, and C. albicans was performed. The results obtained are presented in Figure 3 (for C-silicones: Zetaplus and Oranwash L) and in Figure 4 (for A-silicones: Panasil Putty Soft, Panasil monophase Medium, and Panasil initial contact Light). The summary of the results (means, medians, standard deviations) is also listed in Table A1 . The results of the statistical analysis of the significance of the observed effects are listed in Table 3 . reus, P. aeruginosa, and C. albicans was performed. The results obtained are presented in Figure 3 (for C-silicones: Zetaplus and Oranwash L) and in Figure 4 (for A-silicones: Panasil Putty Soft, Panasil monophase Medium, and Panasil initial contact Light). The summary of the results (means, medians, standard deviations) is also listed in Table A1 . The results of the statistical analysis of the significance of the observed effects are listed in Table 3 . . Effect of four methods (UVC, ozone, solution, and spray) used for the disinfection of C-silicones (Zetaplus and Oranwash L) contaminated with oral pathogens (S. aureus, P. aeruginosa, and C. albicans); the control material was contaminated but not disinfected; p < 0.05 for all comparisons between the study (disinfected) groups and the control group (non-disinfected); detailed results of statistical analysis are included in Table 3 . S. aureus-Staphylococcus aureus; P. aeruginosa-Pseudomonas aeruginosa; C. albicans-Candida albicans; UVC-ultraviolet C. C. albicans); the control material was contaminated but not disinfected; p < 0.05 for all comparisons between the study (disinfected) groups and the control group (non-disinfected); detailed results of statistical analysis are included in Table 3 . S. aureus-Staphylococcus aureus; P. aeruginosa-Pseudomonas aeruginosa; C. albicans-Candida albicans; UVC-ultraviolet C. All disinfection methods evaluated were effective against selected oral pathogens (S. aureus, P. aeruginosa, and C. albicans) contaminating both types of C-silicones ( Figure 3 ). For all of the studied groups, the applied methods of disinfection significantly reduced bacterial and fungal growth when compared to the non-disinfected control material (Table 3). The comparison of the efficacy of different methods of disinfection of A-silicones is presented in Figure 4 . . Effect of four methods (UVC, ozone, solution, and spray) used for disinfection of A-silicones (Panasil Putty Soft, Panasil monophase Medium, and Panasil initial contact Light) contaminated with oral pathogens (S. aureus, P. aeruginosa, and C. albicans); Control material was contaminated but not disinfected; ns-not significant (p > 0.05); for all other comparisons between the study (disinfected) groups and the control (non-disinfected) group, differences were significant (p < 0.05); detailed results of statistical analysis are included in Table 3 . S. aureus-Staphylococcus aureus; P. aeruginosa-Pseudomonas aeruginosa; C. albicans-Candida albicans; UVC-ultraviolet C. For Panasil Putty Soft and Panasil monophase Medium, similarly to the studied Csilicones, all evaluated disinfection methods were effective against selected oral pathogens (S. aureus, P. aeruginosa, and C. albicans) (Figure 4 ). For all of the studied groups, the applied methods of disinfection significantly reduced bacterial and fungal growth on the surface of these two materials when compared to the non-disinfected control material ( Table 3 ). However, when Panasil initial contact Light was evaluated, low effectiveness of the selected methods of disinfection was revealed for the following conditions: UVC radiation against S. aureus (p = 0.9109), UVC radiation against C. albicans (p = 0.6131), and gaseous ozone against P. aeruginosa (p > 0.9999) ( Table 3 ). . Effect of four methods (UVC, ozone, solution, and spray) used for disinfection of A-silicones (Panasil Putty Soft, Panasil monophase Medium, and Panasil initial contact Light) contaminated with oral pathogens (S. aureus, P. aeruginosa, and C. albicans); Control material was contaminated but not disinfected; ns-not significant (p > 0.05); for all other comparisons between the study (disinfected) groups and the control (non-disinfected) group, differences were significant (p < 0.05); detailed results of statistical analysis are included in Table 3 . S. aureus-Staphylococcus aureus; P. aeruginosa-Pseudomonas aeruginosa; C. albicans-Candida albicans; UVC-ultraviolet C. All disinfection methods evaluated were effective against selected oral pathogens (S. aureus, P. aeruginosa, and C. albicans) contaminating both types of C-silicones ( Figure 3 ). For all of the studied groups, the applied methods of disinfection significantly reduced bacterial and fungal growth when compared to the non-disinfected control material ( Table 3) . The comparison of the efficacy of different methods of disinfection of A-silicones is presented in Figure 4 . For Panasil Putty Soft and Panasil monophase Medium, similarly to the studied Csilicones, all evaluated disinfection methods were effective against selected oral pathogens (S. aureus, P. aeruginosa, and C. albicans) (Figure 4 ). For all of the studied groups, the applied methods of disinfection significantly reduced bacterial and fungal growth on the surface of these two materials when compared to the non-disinfected control material (Table 3) . However, when Panasil initial contact Light was evaluated, low effectiveness of the selected methods of disinfection was revealed for the following conditions: UVC radiation against S. aureus (p = 0.9109), UVC radiation against C. albicans (p = 0.6131), and gaseous ozone against P. aeruginosa (p > 0.9999) ( Table 3) . Summarized results revealing the efficacy of the proposed methods of both C-silicones and A-silicones disinfection in most of the studied groups are presented in Table 3 . They are based on the statistical significance of the bacterial and fungal cell growth reduction observed compared to the colony-forming unit counted for the non-disinfected control samples. Only one material (Panasil initial contact Light) was not effectively disinfected using each of the studied methods. Differences between microbial growth observed in the non-disinfected control and in the samples subjected to UVC radiation were not statistically significant for S. aureus (p = 0.9109) and for C. albicans (p = 0.6131), while gaseous ozone was not effective against contamination by P. aeruginosa (p > 0.9999) of Panasil initial contact Light (Table 3) . Development and validation of novel methods of disinfection for dental materials is a topic of high practical value, which could bring enormous benefits, both related to health and the economy. Although awareness of the necessity of the proper disinfection of dental impressions should not raise any doubts, this procedure is still neglected, in particular in developing countries [34] . Due to numerous weaknesses and limitations of the most popular techniques (immersion and spraying), in particular applied for hydrocolloid impressions, their modifications, including the incorporation of the antimicrobial agent to the impression material or mixing with antimicrobial solutions instead of water, have been proposed [35] [36] [37] [38] . Furthermore, alternative methods of disinfection are still sought [39] . Although there are many studies focusing on the effectiveness of alginate impression disinfection, the number of reports concerning silicone disinfection is still limited. Taking into account the favorable properties of elastomeric impression materials and their growing popularity, particularly of polyvinyl siloxanes, these groups of materials deserve special attention in terms of the effect of various techniques of disinfection. To meet these expectations, our study assessed the potential of two methods, which are not commonly applied for disinfection of dental impression, i.e., UVC radiation and ozone treatment, for application to C-silicones and A-silicones. Since UV chambers are commonly used for sterilization of dental instruments, they are available in most dental offices and laboratories. UVC irradiation may be used for microorganism inactivation via damage of the genetic material, which might cause malfunctions in cell replication [40] . Its potential for dental impression disinfection has been investigated by Aeran et al. It was confirmed that UV radiation significantly reduced the number of colonies of oral pathogens grown on the surface of all the studied materials used for taking impressions from the patients (alginate, addition silicone, and polyether). Moreover, the exposure time sufficient for total eradication of bacterial growth was 10 min for alginates, 15 min for A-silicones, and only 3 min for polyether. However, due to the fact that this study was conducted using impressions taken from the patients, there was no detailed information on the specific microbial strains present in the samples [16] . Another study demonstrated lower UV radiation effectiveness than autoclave, used for the elimination of pathogenic microorganisms from alginate impressions [17] . Godbole et al. revealed a lack of a significant negative influence of UV light disinfection on the dimensional stability of polyvinyl siloxane impressions. However, the antimicrobial effectiveness of UV light disinfection was not evaluated in this study [18] . As the existing evidence did not fully characterize the potential of using UV radiation for the elimination of pathogenic microorganisms from various dental impression materials, our results provide valuable insight into this problem. The study was carried out on two types of materials (addition and condensation silicones) of three different types of consistency, which covers a wide spectrum of modern impression materials used for various purposes. Our results confirmed the efficiency of UV light disinfection applied for four out of five tested materials. Disinfection of samples made of Panasil initial contact Light was not successful, which may result from different surface properties of this material, facilitating adhesion of pathogens and hindering its removal when compared to the other materials. Such an explanation could be supported by the results of the study of Giammanco et al., who confirmed that the efficacy of disinfection depends on the materials used for the impressions. One of the two commercial disinfectants studied (Sterigum) was less effective for the addition silicon (Elite) than polyether (Impregum) impression materials disinfection. On this basis, it was concluded that a need for immediate disinfection of impressions should be clearly indicated by manufacturers, and it must be strictly followed by the users [32] . Another low-cost method of disinfection is based on gaseous ozone, which is characterized by a high oxidizing capacity. This unstable molecule consisting of three atoms of oxygen can be used in dentistry for disinfection purposes because of its ability to inactivate bacteria, viruses, fungi, yeast, and protozoa. It can induce the oxidation of phospholipids and lipoproteins, leading to disruption of the integrity of the bacterial cell envelope [41] . The effectiveness of ozone in different virus types' inactivation has also been confirmed [42] . In dentistry, one of the fields of using ozone includes removing the microorganisms from the oral cavity, as well as from dental unit waterlines and disinfection of dentures [43, 44] . Fonseca et al. described the mechanisms of action of ozone as a powerful oxidant able to inactivate Streptococcus mutans, which is one of the principal etiological agents of carious lesions [45] . Although ozone has several advantages over other chemical disinfectants, such as lack of special requirements for storage or mixing, as well as lack of toxic residues harmful to the environment, it instead requires the purchase of a generator and proper, careful handling. Celebi et al. demonstrated a reduction of the growth of bacteria (Escherichia coli, S. aureus, P. aeruginosa, and Enterococcus faecalis) on the surface of A-silicone type impression material (Elite HD+; Zhermack) after treatment with gaseous ozone. Moreover, it had a positive effect on the wettability of the material [13] . Another study revealed that immersion of irreversible hydrocolloid materials in ozonated water can reduce the number of microorganisms (S. aureus, P. aeruginosa, and C. albicans) [43] . Similarly, our study also demonstrated the effectiveness of ozone treatment in the reduction of the growth of microorganisms on the surface of various elastomeric impression materials. The results obtained confirmed previous observations, indicating a need to evaluate each method separately for the specific material. It could be explained by the fact that due to the differences in the chemical composition and surface properties of various materials, the microbial adhesion and growth on their surface may differ. Indeed, it was revealed that the hydrophilic nature of alginates affects their susceptibility to contamination-alginate impressions are considered to have 2-5 fold higher microbial growth compared to elastomeric impression materials [46] . In light of this evidence, it should be concluded that the effectiveness of disinfection applied to various impression materials should be characterized thoroughly. The limitations of this study are mainly related to the in vitro conditions. However, details of procedures performed in everyday clinical practice were carefully reproduced, and international standards were followed. Despite these facts, further research directions include a clinical study involving a real impression taken from the patient to take into account all possible microbial strains that are typically present in the oral cavity and contaminating dental impressions. Undoubtedly, the possible influence of the proposed methods on the physical properties of the impression materials also still requires detailed analysis, which will be a subject of our future study. UVC radiation, gaseous ozone, and liquid chemical are similarly efficient and may be considered as silicone dental impressions disinfection procedures. For most of the studied materials, all of these methods enabled a significant reduction in the growth of common oral pathogens when compared to the non-disinfected control. However, since one type of A-silicone (Panasil initial contact Light) was not effectively disinfected, the potential of each method should be thoroughly investigated for each material separately. Moreover, the influence of UVC radiation and ozone on the physico-chemical and mechanical properties of silicone materials must be evaluated before recommending these low-cost and convenient methods as valuable alternatives of the classic techniques of dental impression disinfection. Dental Impression Materials and Techniques Trueness and Precision of Intraoral Scanners in the Maxillary Dental Arch: An In Vivo Disinfection of Impression Materials: A Comprehensive Review of Disinfection The Effects of Disinfectants on Dimensional Accuracy and Surface Quality of Impression Materials and Gypsum Casts The presence and identification of organisms transmitted to dental laboratories Clinical Evaluation of the Efficacy of Removing Microorganisms to Disinfect Patient-Derived Dental Impressions Cross Infection Control of Impressions: A Questionnaire Survey of Practice among Private Dentists in Hong Kong Handwashing Revisited in Dental Practice during the COVID-19 Outbreak Transmission Routes of 2019-NCoV and Controls in Dental Practice Is saliva a reliable biofluid for the detection of COVID-19? A Comparative Evaluation of Tear Strength and Tensile Strength of Autoclavable and Non-Autoclavable Vinylpolysiloxane Impression Material: An In Vitro Study The Effect of Three Different Disinfection Materials on Alginate Impression by Spray Method. ISRN Dent Disinfection of Polyvinyl Siloxane Impression Material by Gaseous Ozone Evaluation of Effectiveness of Microwave Irradiation for Disinfection of Silicone Elastomeric Impression Material The Disinfection of Impression Materials by Using Microwave Irradiation and Hydrogen Peroxide Use of Clinical UV Chamber to Disinfect Dental Impressions: A Comparative Study Disinfection of impression materials with glutaraldehyde, ultraviolet radiation, and autoclave: A comparative study Evaluation of the Effect of Ultraviolet Disinfection on Dimensional Stability of the Polyvinyl Silioxane Impressions Ultraviolet Light Radiation, Ozone and Electrolyzed Oxidizing Water Disinfection on Properties of Impression Materials: A Systematic Review and Meta-Analysis Study. Saudi Dent Application of Neutral Electrolyzed Water to Disinfection of Alginate Impression Disinfection Procedures: Their Efficacy and Effect on Dimensional Accuracy and Surface Quality of an Irreversible Hydrocolloid Impression Material Comparative evaluation of elastic recovery of three different elastomeric impression materials on chemical disinfection and autoclaving: An in vitro study Effectiveness of Disinfectants on Antimicrobial and Physical Properties of Dental Impression Materials A Simple and Effective Method for Addition Silicone Impression Disinfection Effect of Chemical Disinfection on Surface Detail Reproduction and Dimensional Stability of a New Vinyl Polyether Silicone Elastomeric Impression Material Accuracy of polyether and addition silicone after long-term immersion disinfection Dataset of endodontic microorganisms killed at 265 nm wavelength by an ultraviolet C light emitting diode in root canals of extracted Application of Selected Nanomaterials and Ozone in Modern Clinical Dentistry Dentistry-Elastomeric Impression Materials Chemical Disinfectants and Antiseptics-Quantitative Suspension Test for the Evaluation of Bactericidal Activity in the Medical Area-Test Method and Requirements Chemical Disinfectants and Antiseptics-Quantitative Suspension Test for the Evaluation of Fungicidal or Yeasticidal Activity in the Medical area-Test Method and Requirements Resistance to Disinfection of a Polymicrobial Association Contaminating the Surface of Elastomeric Dental Impressions Rapid colorimetric assay for cellular growth and survival: Application for proliferation and cytotoxicity assays Disinfection of Dental Impressions: Knowledge and Practice among Dental Technicians In Vitro Antimicrobial Activity of Irreversible Hydrocolloid Impressions against 12 Oral Microorganisms Does the Size Matter? Evaluation of Effect of Incorporation of Silver Nanoparticles of Varying Particle Size on the Antimicrobial Activity and Properties of Irreversible Hydrocolloid Impression Material Comparative Evaluation of Disinfecting Alginate Using Aloe Vera and 0.2% Chlorhexidine Digluconate by Internal Disinfection Method-An In Vivo Study Antimicrobial efficacy of irreversible hydrocolloid impression impregnated with silver nanoparticles compared to surface disinfected impressions-An in vivo study Mechanical and Morphological Effect of Plant Based Antimicrobial Solutions on Ultraviolet C irradiation: An alternative antimicrobial approach to localized infections? Ozone Therapy: An Overview of Pharmacodynamics, Current Research, and Clinical Utility Ozone Disinfection for Viruses with Applications in Healthcare Environments: A Scoping Review Prevention of cross-contamination risk by disinfection of irreversible hydrocolloid impression material with ozonated water Activity of Ozonated Water in Sterilising and Disinfecting Dental Unit Water Pipelines System: A Comparative Study Preliminary Study: Comparative Analysis of the Effects of Ozone and Ultrasound on Streptococcus Mutans Effectiveness of Alcohol and Aldehyde Spray Disinfectants on Dental Impressions