key: cord-0863107-nokmeerf authors: Ng, Hoi Lam; Trefz, Johannes; Schönfelder, Martin; Wackerhage, Henning title: Effects of a taped filter mask on peak power, perceived breathlessness, heart rate, blood lactate and oxygen saturation during a graded exercise test in young healthy adults: a randomized controlled trial date: 2022-02-07 journal: BMC Sports Sci Med Rehabil DOI: 10.1186/s13102-022-00410-8 sha: f49cb379460d846c99585dcbeaac6c9652b543fb doc_id: 863107 cord_uid: nokmeerf BACKGROUND: Face masks are an effective, non-pharmacological strategy to reduce the transmission of Severe Acute Respiratory Syndrome Coronavirus-2 and other pathogens. However, it is a challenge to keep masks sealed during exercise, as ventilation can increase from 5 to 10 L/min at rest to up to 200 L/min so that masks may be blown away from the face. To reduce leakage e.g. during exercise, a face mask was developed that is taped onto the face. The aim of this study was to investigate during a graded exercise test the effect of a taped filter mask on the perception of breathlessness, heart rate, blood lactate concentration, and oxygen saturation when compared to a surgical mask and no mask. METHODS: Eight healthy trained participants (4 females), aged 24.5 ± 3.3 years performed graded exercise test until volitional exhaustion under three conditions: (1) No mask/control, (2) surgical mask or (3) taped filter mask. During these tests, we measured perception of breathlessness, heart rate, blood lactate concentration and peripheral oxygen saturation and analysed the resultant data with one or two-way repeated measures ANOVAs. We also used a questionnaire to evaluate mask comfort and analysed the data with paired t-tests. RESULTS: When compared to wearing no mask, maximal workload was significantly reduced with a taped filter face mask by 12 ± 6% (p < 0.001) and with a surgical mask by 3 ± 6% (p > 0.05). Moreover, subjects perceive the sensation of "severe breathlessness" at a 12 ± 9% lower workload (p = 0.012) with a taped face mask, and 7 ± 13% lower workload with a surgical mask (p > 0.05) when compared to wearing no mask. Oxygen saturation at 65% of the maximal workload is 1.5% lower (p = 0.018) with a taped mask than no mask. Heart rate and blood lactate concentration are not significantly different in-between no mask, surgical mask and taped mask at any workload. When compared to wearing a surgical mask, wearing a taped filter face mask has a significantly better wearing comfort (p = 0.038), feels better on the skin (p = 0.004), there is a lower sensation of moisture (p = 0.026) and wearers perceive that less heat is generated (p = 0.021). We found no sex/gender differences for any of the measured parameters. CONCLUSIONS: A taped mask is well tolerated during light and moderate exercise intensity but reduces maximal exercise capacity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13102-022-00410-8. Since December 2019, the global coronavirus disease 2019 (COVID- 19) pandemic has fundamentally changed the way we live, travel and exercise [1] [2] [3] . By the end of January 2022, there were 373 million confirmed cases of COVID-19 globally, and over 5.6 million deaths have been recorded [4] . COVID-19 is caused by the Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) which is a respiratory virus that can be transmitted through droplets, aerosol and SARS-CoV-2-contaminated surfaces [5, 6] . Breathing, speaking, coughing and sneezing can produce droplets and aerosols [7] [8] [9] and SARS-CoV-2 can remain active for hours in aerosol [10] . The COVID-19 pandemic and measures to contain its spread have also affected exercise, sport and sporting events [2] . In relation to this, the arguably most consequential decision was to postpone the 2020 Tokyo Olympic Games to 2021. This was the first time in history that Olympic Games were cancelled due to a health issue [11] . In addition, governments banned competitive sports and closed sporting facilities such as gyms and swimming pools. Not only did this negatively affect the sports economy but it also altered physical activity levels [2] . Face masks are an effective, non-pharmacological strategy to reduce SARS-CoV-2 transmissibility and infection [12] [13] [14] [15] [16] [17] [18] [19] . Face masks can also prevent infections during sport, as Watson et al. [20] reported that the use of face masks was associated with decreased COVID-19 incidence during sports. The question arises, however, whether different types of face masks have negative effects on ventilation, cardiovascular function and metabolism. This issue has been addressed in publications that have measured the effects of different types of face masks on hemodynamic, cardiopulmonary, and metabolic parameters during exercise [18, [21] [22] [23] [24] [25] [26] [27] [28] [29] [30] . Some studies found that wearing a face mask during exercise reduced cardiopulmonary function or exercise performance [9, 24, 27, 28] . However, other studies showed that wearing a face mask does not hinder performance or cardiorespiratory function [21, 22, 29, 30] . These diverse results may result from different study designs and methods, such as constant or progressive load protocols. A limitation of conventional face masks is that air may increasingly escape unfiltered when ventilation increases from 5 to 10 L per minute (L/min) at rest to over 100 L/ min in untrained subjects [31] and up to 200 L/min e.g. in highly trained rowers [32] [33] [34] . Air leakage from the sides of face masks can decrease mask efficacy and is likely to increase the risk of droplet transmission [35] . To address the issue of leakage of unfiltered air at high levels of ventilation, a taped filter mask was developed, where a "filtering facepiece 2" (FFP2) filter is taped onto the face with a liminar KinesioTape. Here, we investigate during graded exercise tests the effect of this taped filter mask on the perception of breathlessness, oxygen saturation, heart rate, blood lactate concentration and exercise performance during a graded exercise test when compared to a surgical mask and no mask. Specifically, we aimed to answer three research questions [36] : (1) Up to what intensity can subjects exercise with a taped filter mask without the perception of major breathlessness and/or a stable drop of the peripheral capillary oxygen saturation (SpO 2 ) to below 80%? (2) How does a taped filter mask affect heart rate and the concentration of blood lactate during a graded exercise test when compared to a surgical mask and no mask? (3) How comfortable is a taped filter mask during a graded exercise test when compared to a surgical mask? This study was approved by the ethical committee of the Technical University of Munich (Approval No. 584/20 S). Eight trained and healthy subjects were recruited and completed the study (Table 1 ). All participants were informed about the experimental procedures, requirements, and risks prior to the start of the study. All participants signed an informed consent form voluntarily and were informed that they can withdraw from the study at any time without consequence. A total of nine participants were invited, eight participants agreed to take part in the study and all of them fit our study inclusion criteria. Participants recruited were university students or from nearby sports clubs. Subject recruitment was done via flyers, notices, and online media such as websites and the "System for recruiting test subjects" ("System zur Probandenrekrutierung") of the Faculty of Sport and Health Sciences (TUM). A taped mask is well tolerated during light and moderate exercise intensity but reduces maximal exercise capacity. (1) No mask control, (2) Commercially available surgical face mask (Fig. 1A ) and a (3) Taped filter mask (Fig. 1B) . The characteristics of the two face masks are described in Table 2 . For a good fit of taped filter masks, male participants in our study used the larger size, whereas female participants used the smaller size. The taped masks were provided by TRC The Rendering Company GmbH (TRC). The measured parameters included perception of breathlessness (dyspnoea scale), heart rate, SpO 2 and blood lactate concentration which we will explain in the following sections (Fig. 2) . Subjects were asked to verbally rate the dyspnoea that they perceived at the end of each stage from a rating of 0-10, using the modified Borg dyspnoea scale [37] ( Table 3) . A copy of the scale including the ratings and their corresponding breathlessness intensities were presented at all times for the participant during the graded exercise test so that the participants could take reference from it. We arbitrarily defined dyspnoea ratings equal or above 7 (very severe) in the modified Borg dyspnoea scale as major breathlessness. Study participants wore a heart rate chest belt (Firstbeat Technologies Oy; FI) which continuously detects heart rate with a sampling frequency of 1 Hz throughout the graded exercise test. The use of Firstbeat device to monitor heart rate has been validated [38] . Oxygen saturation (SpO 2 ) was measured continuously by a pulse oximeter on a fingertip (Nonin 8000A, USA) with a sampling frequency of 5 Hz. Pulse oximetry is a non-invasive method to detect the differential absorption of light from oxygenated and deoxygenated haemoglobin, and thus estimates the percentage of haemoglobin-bound oxygen saturation in the arterial blood [39, 40] . We used the Lode Ergometry Manager software (version 10.6.0) to record oximeter data. To measure the metabolic response to exercise, 20 µl of capillary blood was taken from the earlobe of the subjects to determine the blood lactate concentration. Blood was collected once at rest, at the end of each exercise stage, upon termination of the test, and at 1, 3, and 5 min after the end of the test. Subsequently, we determined the lactate values amperometrically using Biosen S Line device (EKF; GER), which has been used by other studies [41, 42] . The lower detection limit of the instrument was a blood lactate concentration of 0.5 mmol/L. After completing the graded exercise test wearing a surgical mask or a tape filter mask, study participants provided feedback on their subjective well-being and evaluation of the masks during the test by answering a questionnaire. The content of the questionnaire was modified from previous studies [24, 43] (Table 4 ). The questionnaire recorded subjective ratings and qualitative information about the comfort and wearability of the taped filter mask and surgical mask during the exercise test. Using this questionnaire, the subjects evaluated 10 sentences on a visual analogue scale ranging from 0 (totally disagree) to 10 (totally agree) and provided comments in an additional field. All participants underwent a medical fitness examination at the start of the study to ensure they had no contraindication to exercise testing and to check for inclusion criteria. After passing medical screening, subjects participated in three graded exercise tests on three different days. All three tests were performed at the same time of day, within a range of two hours. Minimum time of recovery between the single test was 24 h. No specific diet or fluid intake instruction was given to the participants prior to the testing. No specific instruction was given to avoid exercise before a certain timeframe of the test and participants were asked to maintain their normal weekly routine. For each testing session, participants performed a graded cycling test on a Lode Excalibur bicycle ergometer (Lode, B.V.; NL) until voluntary exhaustion. During these three tests, subjects either wore no mask (control), a surgical mask or a taped filter mask. To avoid potential serial effects, the order of three mask conditions were randomized. The exercise protocol began at a workload intensity of 50 watts (W) and each 3 min, the workload increased by 25 W until exhaustion [44] . We used the Lode Ergometry Manager software (version 10.6.0) to set the protocol and control for the increasing load intensities during the graded exercise test. The test was terminated either during volitional exhaustion, or until subjects reached level 10 on the dyspnoea scale or a stable SpO 2 < of 80% that has been used in other studies as evidence for critical hypoxemia [45, 46] . A sample size estimation was done before the commencement of the study and this study was powered to detect a 5% difference in maximum workload, assuming the peak power output would be 250 W during the exercise test. For statistical evaluation, we used JASP software tool (version 0.12.0) to conduct the statistical analysis. As the duration of three exercise tests varied across conditions, for appropriate analysis of our exercise variables (perception of breathlessness, heart rate, blood lactate concentration and oxygen saturation) with a comparable exercise intensity, data was normalized, interpolated, and expressed in relative to individual peak power achieved (percentage of peak power) in the control condition. The exercise variables were assessed initially by one-way ANOVA for repeated measures to compare between the three conditions. For SpO 2 , heart rate and blood lactate concentration, one-way repeated measures ANOVAs were also done at each normalised workload in a 5%-interval (e.g. at 0% peak power, 5% peak power etc.) to identify any statistical significance between groups at various workloads. If there was a significant [24, 43] Question Statement Your overall condition is very good today 2 The facemask prevents you from your maximal performance 3 The facemask fits very well 4 The wearing comfort of the facemask is very good 5 The facemask material feels very good on the skin 6 The sensation of moisture with the facemask is very low 7 The sense of smell with the facemask is very good 8 Breathing is very difficult with the facemask 9 The heat generated with the facemask is very low main effect, we used Bonferroni post-hoc tests for multiple comparisons. To examine if there were differences between the ratings for surgical mask and taped filter mask from the mask questionnaire, paired t-tests were done for each domain of the questionnaire. For secondary analysis, we added gender as a between-group factor and conducted two-way ANOVA for repeated measures to evaluate if there was a gender difference in all analyses. Significance level was set as p < 0.05 for all statistical tests. Eight participants completed three graded exercise tests each with no adverse effects that required ending an experiment prematurely. Our participants reached 95 ± 3% of their maximal predicted heart rate and a rating of 9.7 ± 0.5 out of 10 of the modified Borg dyspnoea scale when they finished the exercise test. Table 5 shows the main results of the graded exercise test. We now state and answer the three research questions of this study. Our results shows that participants reached a rating of major breathlessness (i.e. a rating of "7") at 68 ± 7% of peak power with the taped filter mask, 73 ± 11% with a surgical mask and 80 ± 10% in the control trial with no mask (Fig. 3A) . Overall, when comparing with wearing no mask, participants reached major breathlessness at 12 ± 9% lower workload (p = 0.012) with a taped filter mask and 7 ± 13% lower workload (p > 0.05) with a surgical mask. Participants reached major breathlessness earlier with a taped filter mask than a surgical mask at 5 ± 7% lower workload but this was not statistically significant (p > 0.05). When gender is added for a between-group factor for secondary analysis with two-way repeated measures ANOVA, no significant differences were found in-between gender (F(1,6) = 1.362, p = 0.288) or for a mask × gender interaction (F(2,12) = 0.163, p = 0.852). The only significant effect was the effect of the mask where subjects with a taped filter mask reached major breathlessness earlier than when wearing no mask (p = 0.021). Specifically, males rated dyspnoea as 7 (very severe) at 65 ± 7% of peak power with the taped filter mask, at 69 ± 10% with a surgical mask and 78 ± 12% in the control trial with no mask, respectively. Females reached a rating of 7 (very severe) at 71 ± 7% with the taped filter mask, 78 ± 12% with the surgical mask and 82 ± 7% of peak performance with no mask, respectively. Overall, participants' SpO 2 values at 65% of the maximal workload were significantly lower by 1.5% when wearing the taped filter mask than when wearing no mask (p = 0.018) (Fig. 3B ). In general, SpO 2 responses to exercise varied greatly in-between subjects, and they dropped to below 85% in two subjects. Only in one participant did the saturation drop below 80% but recovered within seconds and reached 92% at the end of the test. For these reasons, the test was not aborted. There were no statistically significant differences for minimal SpO 2 values between the three mask conditions (F(2,14) = 1.742, p = 0.211), gender (F(1,6) = 0.898, p = 0.380) or mask × gender interaction (F(2,12) = 0.367, p = 0.700). The mean minimal values were 92 ± 3% without wearing a mask, 90 ± 6% when wearing the surgical mask and 89 ± 4% when wearing the taped filter mask. Figure 4 shows the average heart rate and blood lactate concentration during the three exercise conditions, expressed relative to the maximal workload achieved in the no-mask test. There were no significant differences in the heart rate and blood lactate concentration at any workload (p > 0.05), but subjects achieved the highest blood lactate concentrations in the test where they did not wear a face mask. Table 6 shows the blood lactate concentration after exercise. When compared to wearing a surgical mask, subjects felt that the taped filter masks were more comfortable (p = 0.038), felt better on the skin (p = 0.004), reduced the sensation of moisture (p = 0.026) and subjects had a One-way repeated measures ANOVAs were done for each parameter at each normalised workload in a 5%-interval. We performed statistical tests until 90% of peak power because in some trials the subjects did not reach this percentage of their maximal workload. Therefore there was not enough data for statistical analysis. Significant findings are marked with a "*" No Mask Surgical mask Taped mask Fig. 4 Heart rate (A) and blood lactate concentration (B) during graded exercise tests. Heart rate data from all three tests of two participants were excluded due to technical error. The peak blood lactate concentrations were 9 ± 2 mmol/L with no mask, 7.8 ± 1.4 mmol/L with surgical mask and 6.6 ± 2.0 mmol/L when wearing a taped filter mask (Main effect F(2,14) = 6.356, p = 0.011), respectively. Post-hoc analyses reveal that the maximal blood lactate concentration reached with a taped filter mask is significantly lower than that reached with no mask (p = 0.009) reduced perception of heat (p = 0.021) during the graded exercise test (Fig. 5) . For all the other variables, no significant differences were found in-between conditions (p > 0.05). In five out of eight participants the taped filter mask partially detached during vigorous exercise [47] when the corresponding heart rate was 89 ± 4% of the maximal predicted heart rate. Typically, these were small gaps between the adhesive tape and skin after 20.4 ± 3.3 min at 210 ± 22 W. Qualitative feedback provided by the participants are listed in Additional file 1. The main finding of this study is that a taped filter mask significantly reduces the maximal workload in a graded exercise test by 12 ± 6% when compared to no mask. This is no surprise as a well-sealed, taped filter mask will increase breathing resistance. However, a taped filter mask is tolerated well during mild to moderate exercise [47] and was more comfortable to wear than a surgical mask. Participants wearing a taped filter mask perceived major breathlessness (subjectively defined as a dyspnoea scale rating of 7 or above) earlier, at a 12 ± 9% lower exercise intensity when compared to no mask. Our participates reached major breathlessness at 68 ± 7% of peak power with the taped filter mask, which corresponded to reaching 84 ± 5% of the maximal predicted heart rate during vigorous intensity [47] . This might result from the potentially higher breathing resistance (not measured) because of the better sealing of the taped mask. Our results are comparable to those of Wong et al. [9] who reported an increase of rating of perceived exertion (RPE) when they walked for 6 min at 4 km per hour (km/h) when wearing a surgical mask compared to no mask. However, Epstein et al. [22] found no difference in the RPE between no mask, surgical mask and N95 respiratory during graded exercise test on cycle ergometer. This may be explained by the different study protocols [22] as their tests started at 25 W and used a ramp protocol by increasing 25 W every 3 min. They also used a non-invasive nasal prong throughout the tests which may have added breathing resistance to the control/no mask condition. We found, however, no statistical difference in minimal SpO 2 during the exercise tests. One male subject transiently reached a SpO 2 of 75% at 83% of the maximal workload while wearing a surgical mask. However, the SpO 2 recovered quickly and rose to 92% at the end of the test. We continued the test as we interpreted this brief decline to below 80% as a technical error. Precision and accuracy of SpO 2 readings can be affected by technical problems, poor perfusion (e.g. a cold finger) or environmental factors such as movement artefacts [39, 48] . Whilst other studies found no differences between no mask and masks in terms of oxygen saturation [22, 29, 30] or partial pressure of oxygen [24] during exercise, we observed a significantly lower SpO 2 at 65% of the maximal workload when compared to no mask. However, the SpO 2 drop was only 1.5% which should be only a minor difference physiologically (SpO 2 at 65% was no mask: 95.2 ± 1.8%, surgical mask 94.3 ± 1.4%, taped mask 93.7 ± 1.9%). We found no significant difference in the heart rate or blood lactate concentration at any exercise intensity from rest to 90% of the maximal workload achieved in the no mask test. This is consistent with other studies that compared wearing face masks to no mask during graded exercise tests [22, 29, 30] . Two studies [9, 27] , however, Table 6 Post-exercise blood lactate concentrations 14:19 reported significantly higher heart rates when exercisers wore a surgical mask than when not wearing a mask. Wong et al. [9] required healthy adults with a sport background to perform 6-min walking on treadmill (4 km/h) and Lässing et al. [27] conducted 30-min constant-load aerobic exercise on a cycle ergometer at individual's maximal lactate steady state in healthy young men. Also, Li et al. [43] measured a higher heart rate in healthy adults when wearing N95 face mask than surgical mask during a total of 50-min walking in various intensities, ranging from 3.2 to 6.4 km/h. Different subjects, exercise modalities, face masks and intensities may explain these differences. Subjects reached a higher peak blood lactate concentration when wearing no mask. This is primarily explained by the higher workload that the subjects achieved when wearing no mask which is consistent with another study [24] . For the post-exercise blood lactate concentration, the differences between test termination, Post 1, 3 and 5 min did not differ between groups. The result is consistent with the findings of Lässing et al. [27] in which they measured the recovery phase after a constant load exercise with or without surgical mask. Subjects that wore a taped filter mask felt more comfortable, the taped filter mask felt better on the skin and had a reduced sense of moisture or heat from the mask during exercise when compared to wearing a surgical mask. In another study, Li et al. [43] compared the subjective sensations of N95 and surgical face masks during intermittent exercise on a treadmill. They found that participants felt that the surgical mask was drier, cooler, easier to breathe and more comfortable when compared to a N95 mask. Our study is the first to test the comfort of a taped filter mask. In some of the experiments, the taped mask loosened partially and there were gaps between the tape and the skin. This could be a result of the movement of the mouth and nose because of deep breathing in combination with sweating. To ensure good tape adhesion, male users should therefore shave their face before exercise, and participants should avoid makeup or skin creams. We observed a poor mask adhesion in two male participants at their chin. It is unclear whether this was due to beard growth or because of the shape of the face. Some participants commented that the taped face mask is suitable for light and moderate exercise but not during maximal exercise. We did not measure ventilation as a spirometry mask would have affected moisture build-up and thereby the property of face masks worn below a spirometry mask. Testing with a spirometry mask would also reduce external validity of our experiments. Also, we had a small sample size since we only investigated 4 males and 4 females which performed three tests each in randomised order. Furthermore, we arbitrarily defined the criterion for major breathlessness and the questionnaire that we used to assess subjective mask comfort is not validated. Lastly, we did not control the room temperature and relative humidity. In summary, taped filter masks are tolerated well during mild and moderate exercise but they reduce maximal exercise capacity when compared to no mask. Subjects reported that they are more comfortable to wear during exercise on a cycling ergometer than a surgical mask, and they are a potential new tool to avoid becoming infected by SARS-CoV-2 or other infectious agents at rest and during exercise. Future studies may investigate the use of such taped filter masks on other activities such as fitness training in a gym, during sports such as martial arts and in occupations that require well sealing, comfortable face masks. Future variants of taped face masks could have a stronger adhesive e.g. for martial arts or long-duration sports and may include technical solutions to allow drinking during sport. Exploring the impacts of COVID-19 on travel behavior and mode preferences Sport, exercise and COVID-19, the disease caused by the SARS-CoV-2 coronavirus Clinical features of patients infected with 2019 novel coronavirus in Wuhan COVID-19) Dashboard 2021 Coronavirus disease (COVID-19) Airborne or droplet precautions for health workers treating COVID-19? Flow analyses to validate SARS-CoV-2 protective masks. Institute of Fluid Mechanics and Aerodynamics: Neubiberg; 2020 Impact of the COVID-19 pandemic on sports and exercise Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Olympics in the time of a pandemic Physical distancing, face masks, and eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: a systematic review and meta-analysis. The Lancet An evidence review of face masks against COVID-19 Respiratory virus shedding in exhaled breath and efficacy of face masks During the coronavirus (covid-19) pandemic, does wearing a mask improve or worsen physical performance? Reduction of secondary transmission of SARS-CoV-2 in households by face mask use, disinfection and social distancing: a cohort study in Beijing, China Case-control study of use of personal protective measures and risk for SARS-CoV 2 infection Commentary: physiological and psychological impact of face mask usage during the COVID-19 pandemic Making sense of the research on COVID-19 and masks The association of COVID-19 incidence with sport and face mask use in United States high school athletes. medRxiv Peripheral oxygen saturation in older persons wearing nonmedical face masks in community settings Return to training in the COVID-19 era: The physiological effects of face masks during exercise The effect of acute aerobic exercise on arterial blood oxygen saturation of athletes Effects of surgical and FFP2/N95 face masks on cardiopulmonary exercise capacity The physiological impact of masking Is insignificant and should not preclude routine use during daily activities, exercise, and rehabilitation Face masks and the cardiorespiratory response to physical activity in health and disease Effects of surgical face masks on cardiopulmonary parameters during steady state exercise COVID-19 and mask in sports Wearing of cloth or disposable surgical face masks has no effect on vigorous exercise performance in healthy individuals Does wearing a mask while exercising amid COVID-19 pandemic affect hemodynamic and hematologic function among healthy individuals? Implications of mask modality, sex, and exercise intensity Cardio-respiratory reference data in 4631 healthy men and women 20-90 years: the HUNT 3 fitness study Breathing patterns during submaximal and maximal exercise in elite oarsmen Ambrosino N. Ventilatory response to exercise of elite soccer players Respiratory parameters in elite athletes-does sport have an influence? On respiratory droplets and face masks A critique of the hypothesis, and a defense of the question, as a framework for experimentation Wenn die Luft wegbleibt Validation of the Firstbeat TeamBelt and BodyGuard2 systems Pulse oximetry and arterial oxygen saturation during cardiopulmonary exercise testing Pulse oximetry: fundamentals and technology update Comparison of laboratory parameters of a mountain bike specific performance test and a simulated race performance in the field Validity of the Yo-Yo intermittent recovery test level 1 for direct measurement or indirect estimation of maximal oxygen uptake in female soccer players Effects of wearing N95 and surgical facemasks on heart rate, thermal stress and subjective sensations Dauerleistungsfähigkeit des Sportlers: spiroergometrische Beurteilung und Untersuchungsergebnisse von männlichen und weiblichen Personen des 1. bis 8. Lebensjahrzehnts: Barth The frequency of critical incidents at perioperative period in smoking patients Six-minute walk test: observed adverse events and oxygen desaturation in a large cohort of patients with chronic lung disease College of Sports Medicine's guidelines for exercise testing and prescription Analysis and monitoring of gas exchange. Egan's Fundamentals of Respiratory Care Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Not applicable.Authors' contributions HW and MS designed, coordinated, supervised the study and drafted the manuscript. JT designed, coordinated, conducted the experiments and drafted the manuscript. HLN coordinated, conducted the experiments, prepared the figures, conducted statistical analysis, and drafted the manuscript. All authors reviewed and approved the final manuscript. Open Access funding enabled and organized by Projekt DEAL. TRC The Rendering Company GmbH funded this project with the taped mask, and the expenses for participant's medical screening. The online version contains supplementary material available at https:// doi. org/ 10. 1186/ s13102-022-00410-8.Additional file 1: Qualitative feedback from mask questionnaire. In this table it listed participants' feedback on the surgical and taped mask during exercise. The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request. This study was approved by the ethical committee of the Technical University of Munich (Approval No. 584/20 S). All participants signed an informed consent. Consent for publication of the mask images has been obtained from the individual. This study was funded by TRC The Rendering Company GmbH and we agreed the aims of the study with the company. None of the authors received direct payments from TRC The Rendering Company GmbH. The company did not play a role in manuscript preparation nor in the decision for publication.Received: 24 June 2021 Accepted: 27 January 2022