key: cord-0862952-twmk7phc authors: Schneider, Francisco Santos; Molina, Laurence; Picot, Marie-Christine; L’Helgoualch, Nicolas; Espeut, Julien; Champigneux, Pierre; Alali, Mellis; Baptiste, Julie; Cardeur, Lise; Carniel, Christophe; Davy, Martin; Dedisse, Daniel; Dubuc, Benjamin; Fenech, Hugo; Foulongne, Vincent; Gaillard, Carole Fruchart; Galtier, Florence; Makinson, Alain; Marin, Grégory; Santos, Raissa Medina; Morquin, David; Ouedraogo, Alimata; Lejeune, Alexandra Prieux; Quenot, Marine; Keiflin, Pierre; Robles, Francisco Checa; Rego, Carolina Rodrigues; Salvetat, Nicolas; Trento, Charline; Vetter, Diana; Molina, Franck; Reynes, Jacques title: Performances of rapid and connected salivary RT-LAMP diagnostic test for SARS-CoV-2 infection in ambulatory screening date: 2022-02-18 journal: Sci Rep DOI: 10.1038/s41598-022-04826-7 sha: 3b81c528f1cdd680a14fc4a026a0378ebe6bb940 doc_id: 862952 cord_uid: twmk7phc In the context of social events reopening and economic relaunch, sanitary surveillance of SARS-CoV-2 infection is still required. Here, we evaluated the diagnostic performances of a rapid, extraction-free and connected reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay on saliva. Nasopharyngeal (NP) swabs and saliva from 443 outpatients were collected simultaneously and tested by reverse-transcription quantitative PCR (RT-qPCR) as reference standard test. Seventy-one individuals (16.0%) were positive by NP and/or salivary RT-qPCR. Sensitivity and specificity of salivary RT-LAMP were 85.9% (95%CI 77.8–94.0%) and 99.5% (98.7–100%), respectively. Performances were similar for symptomatic and asymptomatic participants. Moreover, SARS-CoV-2 genetic variants were analyzed and no dominant mutation in RT-LAMP primer region was observed during the period of the study. We demonstrated that this RT-LAMP test on self-collected saliva is reliable for SARS-CoV-2 detection. This simple connected test with optional automatic results transfer to health authorities is unique and opens the way to secure professional and social events in actual context of economics restart. www.nature.com/scientificreports/ Concerning the asymptomatic participants (n = 180, 40.6%), 15 subjects (8.3%) were positive according to the CRTest. Only one subject was discordant, with a positive CRTest and a negative salivary RT-LAMP. All the other subjects had concordant results between EasyCOV® and the standard reference test. Performances were therefore Se = 93.3% (95% CI 80.7-100) and Sp = 100% (95% CI 100-100) (Tables 2 and 3 ). Salivary RT-LAMP sensitivity according to virus load. The sensitivity of the RT-LAMP was calculated by varying the cutoffs of NP or salivary RT-qPCR Ct values (30 to 35) used to determine positive individuals ( Fig. 2A) . RT-LAMP sensitivity was associated (R 2 = 0.92) with the salivary RT-qPCR Ct values (sensitivity was 100% when Ct value cutoff < 31 (n = 52)). On the other hand, compared to NP RT-qPCR the sensitivity of the RT-LAMP ranged from 87% (Ct value cutoff < 35) to 89% (Ct value < 30 (R 2 = 0.61)). LAMP was also compared to RT-qPCR performed on NP and salivary specimens, separately. Firstly, RT-LAMP detected 35 individuals not detected by nasopharyngeal RT-qPCR and missed 4 subjects detected by NP RT-qPCR (Supplementary Table S1 ). Sensitivity and specificity were 87.1% (95% CI 75.3-98.9) and 91.5% (95% CI 88.8-94.2), respectively (Table 3) . Finally, the RT-LAMP and RT-qPCR methods performed on the same saliva samples were compared (Supplementary Table S2 ). The sensitivity of RT-LAMP was 91.0% (95% CI 84. 2-97.9 ) and the specificity was 99.5% (95% CI 98.7-100) ( Table 3) . Concordance between saliva and nasopharyngeal specimen using RT-qPCR. After excluding 2 patients with inconclusive NP RT-qPCR results, Gwet's AC1 showed that both RT-qPCR methods are concordant with an agreement of 87.3% (95% CI, 83.3-91.3%): 371/441 participants were negative and 27/441 were positive for the two specimens (Supplementary Table S3 ). Discordant results between NP and saliva specimens were www.nature.com/scientificreports/ www.nature.com/scientificreports/ observed for 43 participants (10%) (Fig. 2B ). Serological analysis performed at least 15 days after RT-qPCRs (n = 5), presence of symptoms compatible with SARS-CoV-2 infection and viral loads strongly suggested that discordant cases were infected cases (Supplementary Table S4 ). Positive participants identified with each assay (NP RT-qPCR, salivary RT-qPCR and RT-LAMP) are shown in a Venn diagram (Supplementary Figure S1 ). Regular in silico alignments of the region targeted by the RT-LAMP test with appearing strain genome sequences permit to identify potential decrease in sensitivity of diagnosis tests. We tested the potential effect of characteristic mutations of the different SARS-CoV-2 variants of concern (VOC) or variants of interest (VOI) defined by WHO (https:// www. who. int/ en/ activ ities/ track ing-SARS-CoV-2-varia nts) on the detection of virus by our assay (Table 4 ). In silico analysis were performed by aligning the six SARS-CoV-2 is detected in various human specimens but none of diagnostic test is ideal for COVID-19 19-21 mass screening. Considering the high specificity of the existing RT-qPCR for SARS-CoV-2 detection, it is relevant to consider an individual as being infected when a RT-qPCR test is positive independently of the specimen 18, 22 . Since NP and salivary RT-qPCR technologies were demonstrated to be complementary 14 , we defined a Composite Reference Test (CRTest) to evaluate the diagnostic performances of the RT-LAMP assay. EasyCOV® is a rapid, extraction-free and connected RT-LAMP salivary test for SARS-CoV-2 detection developed in the beginning of the pandemic burden 23 . The mobile/tablet application EasyCOV Reader® interprets the results of the RT-LAMP assay (positive/negative) and transfers them directly to the sanitary authorities. In addition, this application allows the storage of other data simultaneously (i.e. color parameter of the fluid sample, patient name, date and time of the test, lot number of the assay, serial number of the machine that performed the test, GPS position of the test location). These data can be used in countries or regions to create a map of the geographical distribution of the pandemic. Further, following these data over time enables epidemiologic assessment of the geographical and temporal evolution of the pandemic. Compared to CRTest in our ambulatory screening context, this RT-LAMP assay showed a good performance (Se = 85.92% and Sp = 99.46%) on the total population as well as on symptomatic and asymptomatic individuals. These performances are of the same order as most of the SARS-CoV-2 diagnostic tests, including NP RT-qPCR 19, 20 . By comparison, a recent meta-analysis showed saliva NAAT pooled sensitivity of 83.2% and specificity of 99.2% 14 . The EasyCOV® RT-LAMP test was also recently evaluated against NP RT-PCR, saliva RT-PCR and NP antigenic tests by LeGoff and collaborators 21 . In this study, the authors reported a sensitivity and a specificity of 34% (95%CI 26-44) and 97% (95%CI 96-98), respectively. Their results differed substantially from ours. The worked performed by LeGoff and collaborators was also carried out in France but a few months later than ours and the prevalence of positive participants were similar between the two studies using NP RT-qPCR test (7% for both studies) 21 . On the other hand, when saliva was used as specimen, the prevalence found by LeGoff was clearly lower compared to our clinical study (9% and 5% against 15.2% and 14.2%) using saliva RT-qPCR and saliva RT-LAMP, respectively. These discrepancies should be explained by either saliva miss processing or difference in protocols for the RT-qPCR and RT-LAMP assays. When compared with our study there are two critical methodologic differences in LeGoff study. The authors used negative and positive controls for each run of RT-qPCRs but they did not perform any kind of control when using RT-LAMP assay. In our work presented here, we systematically used positive and negative controls for each analysis, which validate the correct use or correct storage of the RT-LAMP test. Besides, LeGoff et al. reported that the result of the RT-LAMP test was performed using a pH sensitive reagent 21 . Actually, the specifications of the EasyCOV® RT-LAMP assay explicitly mention that the use of the intercalant reagent SYBR green is requested to reveal the presence of the amplicons in the reaction tube even for colorimetric readout. LeGoff et al. read by visual observation the coloration of the tube after reaction while we used the dedicated smartphone/tablet application EasyCOV Reader®, which is preconized by the manufacturers to avoid any well-known subjective interpretation of the readout depending on the light of the room and the operator. EasyCOV Reader® was developed to provide objective interpretation of the results of the RT-LAMP test. SARS-CoV-2 presents a moderate mutation frequency [24] [25] [26] . Over the course of evolution, some variants become preponderant in human populations (e.g. "UK variant"-lineageB.1.1.7) and raise widespread concern 27-29 . Genetic variants can lead to false negative SARS-CoV-2 molecular testing if mutations occur in the targeted regions of the primers or probes of the diagnosis tests. We evaluated the frequency of sequenced variants in France and over the World presenting mutations in the annealing region of the RT-LAMP primers during the period of the study of LeGoff and collaborators and ours. No dominant mutation was observed and our analysis shows that 91.9 to 99.1% of all sequenced samples presented 100% of identity with the target sequence of RT-LAMP primers between May 2020 and February 2021 in France and 95.0 and 97.1% over the World (Supplementary Table S6 ). Further, continuous surveillance allows to evaluate the capability of EasyCOV® to detect the new appearing strains of SARS-CoV-2. Four recent mutated variants (AY.25, AY.34, B.1.621 and B.1.621.1) present mutations in the region targeted by RT-LAMP primers but together they represented only 6.6% of all the sequenced specimens in samples collected in the last four months. Various other RT-LAMP tests using extraction/purification steps were developed to detect SARS-CoV-2 [30] [31] [32] [33] . Their sensitivities on NPS samples were equivalent to that of RT-qPCR [30] [31] [32] . Nagura-Ikeda et al. 34 compared six different NAATs (including one RT-LAMP) and an antigen test using self-collected saliva from hospitalized patients. The sensitivities of the evaluated tests for SARS-CoV-2 detection were 50.5 to 81.6% (70.9% by RT-LAMP) using NAATs and 11.7% using the antigen test. Yokota et al. 8 www.nature.com/scientificreports/ Further, a recent meta-analysis found a high pooled sensitivity for antigen rapid diagnostic tests (Ag-RDTs) when using NP samples and a Ct cutoff for RT-qPCR < 30 (79.90% (95%CI 70-87). However, for saliva specimen the pooled sensitivity found was 37.9% (95%CI 12-74) independently of the Ct cutoff used for the reference standard RT-qPCR 35 . Despite the rapidness and the low-cost of Ag-RDTs, the observed performances in the meta-analysis were lower compared to EasyCOV® and NP sampling is still required for Ag-RDTs to achieve even moderate diagnostic performances. We also compared the salivary RT-LAMP to the salivary RT-qPCRs separately. The RT-LAMP test presents good performances compared to salivary RT-qPCR and its sensitivity was associated with the Ct value cutoff in salivary RT-qPCR. The six misdiagnosed subjects by RT-LAMP presented Ct values ≥ 31, reflecting the higher LOD (limit of detection) of the RT-LAMP compared to the RT-qPCR. Our results corroborated previous results comparing salivary RT-LAMP and RT-qPCR performances and demonstrated similar performances between the two methods [36] [37] [38] [39] . Compared to nasopharyngeal RT-qPCR only, the RT-LAMP showed a weaker specificity and PPV, reflecting the negative individuals misclassified by NP RT-qPCR but also detected positive by salivary RT-qPCR. Further, viral load in NPS samples was weakly associated to RT-LAMP sensitivity as there was no correlation between salivary and NP RT-qPCR Ct values (Spearman correlation = 0.19), suggesting different saliva and NPS viral loads, corroborating previous works 6, 40 . Further, we analyzed 443 saliva and NP paired samples using optimized RT-qPCR protocols to deal with the two different specimens. A total of 71 individuals were positive from which 43 had discordant results between NP and salivary RT-qPCR. Most (n = 39) were detected positive only in saliva while clearly negative in NP RT-qPCR without Ct value. Five individuals proceeded to a serological test and all were positive, corroborating the salivary RT-qPCR results and suggesting an infection at sampling. Contrarily, four participants were positive in NP RT-qPCR only. For three of them, the presence of the viral RNA at low loads in saliva was observed (Ct value ≥ 35). Different kinetics of virus replication in saliva and NP have already been described 6, 7 . In our study, NP RT-qPCR broadly underestimated the number of positive cases detected using salivary RT-qPCR and salivary RT-LAMP. Low sensitivities have also been reported earlier 19, 20 and might reflect the difficulty of the NPS sampling. Collecting saliva is a non-invasive and easy procedure in contrast with NP or OP swabs. In ambulatory practice, the use of saliva to detect SARS-CoV-2 has several advantages. It avoids individual's discomfort, minimizes healthcare personnel exposure and well accepted by population. Accordingly, we showed the feasibility of saliva self-sampling in asymptomatic or mildly symptomatic outpatients. Despite NPS being the most used sampling method, saliva was demonstrated to be a reliable specimen for the detection of SARS-CoV-2 in other several studies 6, 8, 9, 11, 21, 32, [41] [42] [43] and our results showed that saliva presents a superior performance for COVID-19 diagnosis using RT-qPCR compared to NPS. The rapidness, easiness and performances of the RT-LAMP EasyCOV®, combined with acceptability of saliva sampling 2,3 , confirm the usability (no need of laboratory facilities) of extraction-free salivary RT-LAMP tests for SARS-CoV-2 screening in a point of care setting. The secured internet connectivity of this device allows the real-time management of crowds in the context of social events, border control and professional and educational plants in which a negative test would be required for accessing controlled sites. This assay is already employed in airports and country borders as well in companies to test employers. Altogether, our results demonstrate that the rapid salivary RT-LAMP is an operational alternative for SARS-CoV-2 detection in the context of safe economic and social reopening. Study design and population. In this monocentric diagnostic study, adults coming to the COVID-19 screening centre of University Montpellier Hospital between 22th May and 7th of October 2020 with COVID-19 compatible symptoms and/or being contact-cases of confirmed COVID-19 cases were prospectively invited to participate. Symptoms, risk factors, medical history and treatments were informed on a self-administered questionnaire under supervision of a practitioner. A participant was considered asymptomatic if no symptom was declared at the time of sampling. Participants were requested to self-collect 2 mL of saliva by salivating in a 50 mL polystyrene tube and then proceeded to a simultaneous and mandatory NPS sampling by a trained nurse. Saliva samples were immediately stored at 4 °C and sent within 3 h to the research laboratory Sys2Diag. Once at Sys2Diag, each sample was separated into two new tubes and routed to two different laboratory rooms for RT-qPCR and RT-LAMP analysis, following the international laboratory-guidance, by independent biologists blinded of the infectious status of the participants and the results of NP RT-qPCR. NPS were discharged in 1 mL viral transport medium (VTM) and samples were tested by RT-qPCR by independent blinded virologists at the hospital. The study and all subsequent amendments was approved by a French ethic committee (CPP-Ile de France XI) on April 03, 2020. The study was registered at www. clini caltr ials. gov (NCT04337424). All methods were performed in accordance with relevant guidelines and regulations. All participants signed informed consent prior to participating. saliva was performed as described earlier 23 . Briefly, samples were treated in the presence of DTT (10 mM) for 30 min at room temperature. Then, RNA extraction was performed using Nucleospin Dx Virus Kit (Macherey Nagel). 2 μL of purified RNA were added to Invitrogen superscript III Platinium One step reaction mix (#11,732,020) containing 1X reaction mix, MgSO4 (0.8 mM) a DNA-primer mix aiming two RdRp targets (IP2 and IP4). Primers and probes (nCoV_IP2 and nCoV_IP4) were designed to target the RdRp gene spanning nt 12,621-12,727 and 14,010-14,116 (positions according SARS-CoV, NC_004718) 44 . Real-time detection and thermal cycling conditions were identical to previously described 23 . Saliva samples were analyzed in triplicate and RT-qPCR Ct values were the mean of these results. An absence of amplification on replicates was expressed as Ct = 40 which is the maximum value obtained by our method. For each experiment, we performed positive and negative controls using a SARS-CoV-2 synthetic RNA (CODEX DNA, SC2-RNAC0500), well-characterized positive and negative saliva samples and no template control (H 2 O). The robustness of the salivary RT-LAMP test was assessed. Replicability of experiment was performed testing each clinical sample in triplicate. The sensitivity was also calculated with a random sampling without replacement on the triplicated tests using the bootstrap method (5000 sample tests) (Table S5 ). Performances obtained using bootstrap (Supplementary Table S5 ) or single point analyses (data not shown) were similar to those considering at least two out of three replicates as positive. For the reproducibility of the RT-LAMP test, 30 subjects were randomly asked to be sampled twice in two separate tubes at the same moment. Each sample was analysed separately and the raw concordance between the two samplings was of 96.9% (data not shown). Android) which assists the interpretation of EasyCOV® result. At the end of the assay, the colored tube two is photographed by an operator using the application. The software automatically determines the position of the fluid sample in the tube and the position of the tube on the reference template. From a colorimetric analysis based on the HSV space (Hue, Saturation Value) of the fluidic sample (patent pending) and taking into account the brightness parameters, the software provides an instant result (virus detected/virus not detected). EasyCOV Reader® records patient's information and registers the image of tube two. The result is real time displayed and recorded in a secured online database. Then any authorized entity can access a real time desktop to monitor the results of ambulatory testing. The sequences of SARS-CoV-2 variant genomes were downloaded with their metadata from the data base GISAID 45 on November 02, 2021. Then genomes were aligned with the Easy-COV primers with the software MUMmer4 (version 4.0.0 release candidate 1). For each pair of primer/genome the larger alignment was kept. The alignment data and Metadata were merged with Bash (version 5.0.3) and python (version 3.7.3) scripts. Finally, with an R script (version 4.0.5) it was possible to isolate genomes of interest; those from variants found in Homo sapiens, with high coverage (less than 1% of Ns) and complete (with more than 29 kb). It was also possible to identify for each month, genomes of interest aligning without any mismatch or insertion or deletion with the full-length primer sequences in the expected positions. Sample size. The sensitivity of NP RT-qPCR for SARS-CoV-2 detection was estimated at 71% 19, 20 . Considering a sensitivity for the RT-LAMP of 70%, with an accuracy of ± 10% of the 95% confidence interval (CI), we calculated that 80 participants positive for SARS-CoV-2 infection had to be included. With an estimated prevalence rate of 15% at the screening center of our Hospital University, we thus aimed at recruiting about 533 individuals. Values were expressed as mean + /− standard deviation (SD) for continuous variables and number with percentages for categorical ones. Comparisons of the clinical characteristics between positive and negative patients were performed with Student or non parametric (Wilcoxon-Mann-Whitney, WMW) tests for continuous variables and with chi-2 test for categorical variables. www.nature.com/scientificreports/ The performance of the diagnostic tests was evaluated by their sensitivity (Se) and specificity (Sp) with their 95% confidence interval. Sensitivity was the proportion of positive index test in the infected population and specificity the proportion of negative in the non-infected population, according to the reference diagnosis. Since our study was carried out in a real screening context, the positive and negative predictive values were also calculated with their 95% CI for the index test. Accuracy (true positive plus true negative cases divided by the total number of participants) was also reported. Sub-group analysis was performed according to the presence/ absence of symptoms. The concordance between nasopharyngeal and salivary RT-qPCR was assessed by calculating the Gwet's agreement coefficient (AC1) as positive and negative distributions were unbalanced. All statistics were performed using SAS Enterprise Guide, v7.3 (SAS Institute Inc, Cary, NC, USA). www.nature.com/scientificreports/ Effect of throat washings on detection of 2019 novel coronavirus Willingness to use home collection methods to provide specimens for SARS-CoV-2/COVID-19 research: survey study Willingness to seek diagnostic testing for SARS-CoV-2 with home, drive-through, and clinic-based specimen collection locations Simulation of the clinical and pathological manifestations of coronavirus disease 2019 (COVID-19) in a golden syrian hamster model: Implications for disease pathogenesis and transmissibility Saliva is a reliable tool to detect SARS-CoV-2 Saliva or Nasopharyngeal swab specimens for detection of SARS-CoV-2 Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study Mass screening of asymptomatic persons for SARS-CoV-2 using saliva Comparing nasopharyngeal swab and early morning saliva for the identification of SARS-CoV-2 Saliva sample as a non-invasive specimen for the diagnosis of coronavirus disease 2019: a cross-sectional study Hock-a-loogie saliva as a diagnostic specimen for SARS-CoV-2 by a PCR-based assay: A diagnostic validity study Saliva as a noninvasive specimen for detection of SARS-CoV-2 Sensitivity of nasopharyngeal swabs and saliva for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Comparison of saliva and nasopharyngeal swab nucleic acid amplification testing for detection of SARS-CoV-2: A systematic review and meta-analysis A global database of COVID-19 vaccinations Associations of vaccination and of prior infection with positive PCR test results for SARS-CoV-2 in airline passengers arriving in qatar Diagnostic excellence Viral RNA load as determined by cell culture as a management tool for discharge of SARS-CoV-2 patients from infectious disease wards Sensitivity of Chest CT for COVID-19: Comparison to RT-PCR Correlation of chest CT and RT-PCR testing for coronavirus disease 2019 (COVID-19) in China: a report of 1014 cases Evaluation of a saliva molecular point of care for the detection of SARS-CoV-2 in ambulatory care Predicting infectious SARS-CoV-2 from diagnostic samples EasyCOV: LAMP based rapid detection of SARS-CoV-2 in saliva SARS-CoV-2 one year on: evidence for ongoing viral adaptation Temporal signal and the phylodynamic threshold of SARS-CoV-2 Mutational frequencies of SARS-CoV-2 genome during the beginning months of the outbreak in USA Genetic variants of SARS-CoV-2-what do they mean Immunity to SARS-CoV-2 variants of concern Tracking changes in SARS-CoV-2 Spike: Evidence that D614G increases infectivity of the COVID-19 Virus Development and clinical application of a rapid and sensitive loop-mediated isothermal amplification test for SARS-CoV-2 Infection Evaluation of rapid diagnosis of novel coronavirus disease (COVID-19) using loop-mediated isothermal amplification Diagnostic accuracy of loop-mediated isothermal amplification coupled to nanopore sequencing (LamPORE) for the detection of SARS-CoV-2 infection at scale in symptomatic and asymptomatic populations Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay Clinical evaluation of self-collected saliva by quantitative reverse transcription-PCR (RT-qPCR), Direct RT-qPCR, reverse transcription-loop-mediated isothermal amplification, and a rapid antigen test to diagnose COVID-19 Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis A molecular test based on RT-LAMP for rapid, sensitive and inexpensive colorimetric detection of SARS-CoV-2 in clinical samples Developing RT-LAMP assays for detection of SARS-CoV-2 in Saliva Rapid and extraction-free detection of SARS-CoV-2 from saliva by colorimetric reverse-transcription loopmediated isothermal amplification Field-deployable, rapid diagnostic testing of saliva for SARS-CoV-2 A novel saliva RT-LAMP workflow for rapid identification of COVID-19 cases and restraining viral spread Detection of SARS-CoV-2 from saliva as compared to nasopharyngeal swabs in outpatients The sensitivity and costs of testing for SARS-CoV-2 infection with saliva versus nasopharyngeal swabs : A systematic review and meta-analysis Comparative evaluation of nasopharyngeal swab and saliva specimens for the molecular detection of SARS-CoV-2 RNA in Japanese patients with COVID-19 Performance assessment of SARS-CoV-2 PCR assays developed by WHO referral laboratories Data, disease and diplomacy: GISAID's innovative contribution to global health We thank Nicolas Doll and all the NEB France team from New England Biolabs for technical support, Caroline Goujon and Ana-Luiza Valadão for helpful scientific discussion, Victor Petit, Sofia El Annabi, Alexandre Lassaigne from Skillcell, Patrick Collet, Yann Pichot, Marine Bittel from TRONICO, Marc Delmas, from PMB, Pascaline Dubs, Guillaume Rochet from CNRS for technical discussions, developments and kind support, Catherine Isel-Griffiths and Valérie Macioce for proofreading the manuscript, Thérèse Galindo and Sys2diag members for their day basis support during such complicated period. We thank the study participants and all of the staff of clinical research team (Charlotte Kaan, Maelle Dereure, Hugues Chevassus, Philippe Géraud, Laura Crantelle and colleagues) as well as CAPES/COFECUB for internship grants for C.R.R. and R.M.S. F.S.S., L.M. and M.C. P. served as co-first authors and contributed equally to the work. F. M. and J. R. contributed equally to the work. Study concept and design: F.S.S., L.M., M.C.P., F.G., F.M., and J.R. Acquisition, analysis, or interpretation of data: All authors. Drafting of the manuscript and critical revision of the manuscript for important intellectual content: F.S.S., L.M., M.C.P., N.L.H., J.E., P.C., F.M., and J.R. Statistical analysis: F.S.S., L.M., M.C.P., C.C., D.D., G.M., P.K., F.C.R., and N.S. Authors F. M. and J. R. had full access to all the data in the study and take responsibility for the integrity of the data and the accuracy of the data analysis. All authors read and approved the final manuscript. This study was supported by SkillCell, the Centre National de Recherche Scientifique and the Occitanie Region. Correspondence and requests for materials should be addressed to F.M. Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.