key: cord-0861776-pifrxezk authors: Ploumen, Eline H.; Buiten, Rosaly A.; Kok, Marlies M.; Doggen, Carine J.M.; Roguin, Ariel; Jessurun, Gillian A.J.; Schotborgh, Carl E.; Danse, Peter W.; Benit, Edouard; Aminian, Adel; van Houwelingen, K. Gert; Stoel, Martin G.; Scholte, Martijn; Hartmann, Marc; Linssen, Gerard C.M.; Zocca, Paolo; von Birgelen, Clemens title: Treating diabetic all-comers with contemporary drug-eluting stents: Prespecified comparisons from the BIO-RESORT and the BIONYX randomized trials() date: 2020-10-22 journal: Int J Cardiol DOI: 10.1016/j.ijcard.2020.10.051 sha: 4010477de793e396ec739a8b3b3657c4e80a9386 doc_id: 861776 cord_uid: pifrxezk BACKGROUND: Patients with diabetes have more extensive coronary disease, resulting in higher risks of adverse clinical events following stenting. In all-comer patients, contemporary DES have shown excellent safety and efficacy, but data on diabetic patients are scarce. Separately for the BIO-RESORT and BIONYX trials, we assessed the 2-year clinical outcomes of diabetic patients, treated with various contemporary drug-eluting stents (DES). METHODS: We performed two prespecified secondary analyses of two randomized DES trials, which both stratified for diabetes. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. Follow-up was finished before the COVID-19 pandemic. RESULTS: In BIO-RESORT, 624/3514 (17.8%) had diabetes: 211 received SES, 203 Synergy everolimus-eluting stents (EES), and 210 Resolute Integrity zotarolimus-eluting stents (RI-ZES). TVF did not differ between SES (10.2%) and EES (10.0%) versus RI-ZES (12.7%) (SES vs. RI-ZES HR:0.78, 95%-CI [0.44–1.40]; p = 0.40, EES vs. RI-ZES HR:0.79, 95%-CI [0.44–1.40]; p = 0.42). In BIONYX, 510/2488 (20.5%) patients had diabetes: 250 received SES and 260 Resolute Onyx zotarolimus-eluting stents (RO-ZES). There was no difference in TVF between SES (10.7%) versus RO-ZES (12.2%) (HR:0.88, 95%-CI [0.52–1.48]; p = 0.63). CONCLUSIONS: There was no difference in 2-year clinical outcome among patients with diabetes, who were treated with SES, or EES, versus RI-ZES. In addition there was no difference in clinical outcome in diabetic patients, who were treated with SES versus RO-ZES. These findings may be considered as a signal of safety and efficacy of the studied DES in patients with diabetes. Patients with diabetes have more extensive coronary artery disease with a lumen size that is on average smaller than in patients without diabetes (1) . The coronary arteries of diabetic patients generally have more lipid-rich plaque with more macrophage infiltration and a greater plaque burden (2, 3) . As a consequence of the more advanced atherosclerotic vascular changes, patients with diabetes have a higher risk of adverse clinical events after percutaneous coronary intervention (PCI), such as repeat revascularization, stent thrombosis, and mortality (4, 5) . Several randomized clinical trials have demonstrated the safety and efficacy of PCI with contemporary drug-eluting stents (DES) in all-comer patients (6) (7) (8) (9) (10) . However, in patients with diabetes there is limited evidence that supports the use of contemporary DES, such as the Orsiro sirolimus-eluting stent (SES; Biotronik, Bülach, Switzerland), the Synergy everolimus-eluting stent (EES; Boston Scientific, Marlborough, MA), and the Resolute Integrity zotarolimus-eluting stent (RI-ZES; Medtronic, Santa Rosa, CA) (11) (12) (13) (14) (15) (16) (17) . The study design and details of the BIO-RESORT (Comparison of biodegradable polymer and durable polymer drug-eluting stents in an all-comers population; NCT01674803) and BIONYX (Bioresorbable polymer-coated Orsiro versus durable polymer-coated Resolute ONYX stents; NCT025087140) trials have been reported previously (6, 7) . For both trials, patients were eligible for enrollment, if they were aged 18 years or older, capable of providing informed consent, and required PCI. There was no restriction for target lesion type (i.e., de novo, restenosis, or graft), lesion length, reference vessel size, clinical syndrome, and number of lesions or vessels to be treated. BIO-RESORT is a 3-arm, patient-and assessor-blinded study, performed at 4 cardiac centers in the Netherlands. Patients were randomized to treatment with the Orsiro SES (Biotronik), the Synergy EES (Boston Scientific) versus the RI-ZES (Medtronic) (6) . The international BIONYX trial is a patient-and assessor-blinded study that was performed in 7 specialized cardiac centers in the Netherlands, Belgium, and Israel. Patients were randomized to treatment with the RO-ZES (Medtronic) versus the Orsiro SES (Biotronik) (7) . In both trials, randomization was stratified for the presence of diabetes, and in BIONYX randomization was also stratified for sex. Figure 1 All coronary interventions were performed according to international medical guidelines and the operator's judgement. Overall, a total of 4 types of contemporary DES were used. The SES elutes sirolimus within 4 months from a circumferential, asymmetrical (thicker on abluminal side) biodegradable coating that is resorbed within 24 month; the SES has 60-µm (for ≤3.0-mm stents) or 80-µm (for >3.0-mm stents) cobalt-chromium struts that are covered by a thin passive coating of amorphous silicon carbide (6) . The EES elutes everolimus within 3 months from a poly(lactic-co-glycolic acid) coating that is located only on the abluminal side of 74-μm (for ≤2.5-mm stents), 79-μm (for 3.0to 3.5-mm stents), or 81-μm (for 4.0-mm stents) platinum-chromium struts and is resorbed within 4 months. The RI-ZES has thin, round 91-μm cobalt-chromium struts that are circumferentially covered by a blend of three durable polymers, which elutes zotarolimus within 6 months (6). Its iteration, the RO-ZES also elutes zotarolimus for 6 months from the same type of polymer-blend, covering 81-μm (for ≤4.0-mm stents) or 91-μm (for 4.5-5.0-mm stents) composite wire struts. The stent platform of RO-ZES is made from a single-strand of swaged shape cobalt-chromium wire with a platinum-iridium core that is manufactured into a sinusoidal waveform (7). For both trials, clinical follow-up was obtained at visits to outpatient clinics, by telephone, or by medical questionnaire. All follow-up data were obtained before the corona virus disease 2019 (COVID-19) pandemic. Thus, the event rates that we report, in particular the mortality rates, are unaffected by the COVID-19 pandemic. The trials were monitored (Diagram, Zwolle, Netherlands), and events were adjudicated by independent committees that were blinded for the assigned stent (Diagram, Zwolle, the Netherlands, or cardiologists of the Differences in categorical variables were examined with Pearson's χ² or Fisher's exact test, as appropriate, and differences in continuous variables with the t test. Time to endpoints was assessed by the Kaplan-Meier method, and the log-rank test was applied for between-group comparisons. Hazard ratios (HR) with 2-sided confidence intervals (CI) were computed by Cox proportional hazards analysis. A two-sided p-value <0.05 was considered significant. To adjust for the stratification factor (sex), which was used at randomization in BIONYX, an additional analysis was performed that calculated an adjusted hazard ratio for the main outcome with a Cox model. Statistical analyses were done with SPSS version 24.0 (IBM, Armonk, NY). Of all 3,514 BIO-RESORT trial participants, a total of 624 (17.8%) had diabetes. These patients were on average 66.5±10.1 years old. Approximately one third of the diabetic patients was of female sex (32.1%). The body mass index was 29.3±4.7 kg/m2, and 35.3% were treated with insulin. Most patients (60.9%) presented with an acute coronary syndrome. Between stent groups, there was no significant difference in baseline patient, lesion, or procedural characteristics. Additional baseline patient, lesion, and procedural data are presented per stent group in Table 1 . Two-year follow-up was available in 617 (98.9%) diabetic patients: 3 were lost to follow-up and 4 withdrew their consent. Patients were censored at the last known contact (lost to follow-up), or at moment of drop-out (consent withdrawal). Table 2 Figure 2 . Definite-or-probable stent thrombosis rates were low and similar in all 3 stent groups (SES 1.4%, RI-ZES 1.9%, and EES 1.5%). Supplementary Table 1 presents the clinical outcome of diabetic patients with (N = 220) and without insulintreatment (N = 404), showing no significant differences between stent groups. Of the 2,488 participants in the BIONYX trial, 510 (20.5%) were known to have diabetes. Diabetic BIONYX trial participants were on average 66.4±10.3 years old (female sex in 28.6%). Their body mass index was 29.5±5.0 kg/m2, and medication included insulin in 35.7%. The majority of patients (65.1%) were treated for an acute coronary syndrome. There was no significant between-stent difference in baseline patient, lesion, or procedural characteristics. Table 1 presents additional baseline patient, lesion, and procedural data per stent group. The 2-year follow-up was available in 500 (98.0%) patients: 7 were lost to follow-up and 3 withdrew their consent. Table 2 Among BIO-RESORT trial participants who were treated with EES or RI-ZES, the 2-year TVF rates increased with the severity of diabetic status. Patients without diabetes had the lowest TVF rates (6.2% and 7.3%, respectively), followed by diabetic patients without insulin treatment (8.8% and 10.6%), and diabetic patients with insulin treatment had the highest rates (12.2% and 16.3%, respectively). Likewise, in the RO-ZES-treated BIONYX trial participants, the 2-year TVF rates were 6.4%, 11.1%, and 14.1%, respectively. Overall, the observed event rates and the relation between the rate and the diabetic status are in line with previous studies (14,17,22 ). In the SES-arms of BIO-RESORT and BIONYX, the 2-year TVF rates were quite low in insulin-treated and non-insulin-treated diabetic patients (10.2% and 10.1%, as well as 8.3% and 11.8%, respectively). A previous study that assessed the SES in insulin-treated patients observed a dissimilar pattern with higher event rates in insulin-treated diabetic patients (12) . Subtle differences in procedural details (e.g. stent postdilation) or concomitant medication might have played a role. Furthermore, we cannot exclude that a play of chance might have contributed to the surprisingly low TVF rates in the two relatively small insulin-treated diabetic SES-patient subgroups of both trials. As diabetic patients have a greater coronary plaque burden with a higher degree of lesion calcification, DES with very thin and ultrathin struts might have a theoretical disadvantage in plaque scaffolding, related to a slightly lower metal-to-artery ratio and radial force. The latter may be compensated for by refinements in strut material or shape, and in stent design. In addition, very thin and ultrathin struts may be advantageous in patients with smaller caliber coronary vessels, such as patients with diabetes, as the relative effect of strut size on lumen obstruction may be greater in small vessels. Furthermore, the use of biodegradable polymer coatings could be advantageous, as after polymer resorption only the metallic stent platform remains in the vessel, which may improve vascular healing (23). Therefore, it is of interest to The present study is the first to report 2-year clinical outcomes of diabetic all-comer patients treated with RO-ZES. In addition, it is the first study to present 2-year results from a head-to-head comparison of the biodegradable polymer EES, as well as the ultrathin-strut biodegradable polymer SES, versus a reference stent in diabetic all-comers. In a study that compared the ultrathin-strut SES with a thin strut durable polymer everolimus-eluting stent (Xience Prime/ Xpedition, Abbott Vascular) in 486 patients with known diabetes, similar 5-year target lesion revascularization rates were observed for both DES (16.9% vs. 15.8%, p=0.68) (13) . Furthermore, a patient-level pooled analysis of three randomized trials (i.e., BIOFLOW II, IV, and V) that assessed the outcome of a total of 757 patients with diabetes found no difference in 1-year clinical outcome of patients treated with the SES versus the Xience Prime everolimus-eluting stent (12) . In the SORT OUT VII trial, the 2-year rate of the composite endpoint target lesion failure rate (i.e., cardiac death, target vessel MI, or target lesion revascularization) was 9.3% in 236 diabetic patients who were treated with SES, showing no difference as compared to a biodegradable polymer-coated biolimus-eluting stent (15). In the present assessment of the ultrathin-strut SES, we observed a similarly low 2-year target lesion failure rate. Thus, both the previous studies as well as the current analysis reveal an excellent safety and efficacy of the ultrathin-strut SES in patients with diabetes. The very thin strut biodegradable polymer EES was previously investigated in the diabetic patient subgroups of two clinical studies. Although the EVOLVE II diabetes substudy (11) assessed a somewhat more selected patient population than the present all-comer trials, the 2-year rate of target lesion revascularization (6.8%) was higher than in diabetic patients of the EES-group of BIO-RESORT (3.6%). In that study, the rates of safety endpoints were similar to our observations (target vessel MI 6.4% and 5.0%, cardiac death 1.5% and 2.0%, respectively). We can only speculate that differences in ischemia assessment, namely the While this manuscript reports two individual prespecified sub-group analyses in diabetic patients of two large-scale randomized DES trials which both stratified for the presence of diabetes, the sample sizes were insufficient to draw definite conclusions, and for that reason the findings are no more than hypothesis generating. Statistical power of these secondary analyses is limited, and we cannot exclude that small differences in outcome remained undetected due to sample size limitations. Nevertheless, the results provide a signal of safety and efficacy for treating this subset of patients with the contemporary DES that were examined in the trials. Despite some methodological limitations, a pooled data analysis of both trial's diabetic patient populations is of interest for future research. Considering the ongoing COVID-19 pandemic, for the time being the BIONYX trial may be the only source of unimpaired, monitored, 2-year outcome data in all-comers who were treated with RO-ZES. While event rates (specifically mortality rates) in this manuscript can be adequately compared to the rates of previous studies, future follow-up of this and other trials may be affected by the COVID-19 pandemic, which will make meaningful comparisons more challenging. There was no difference in 2-year clinical outcome among patients with diabetes, who were treated with SES, or EES, versus RI-ZES. In addition there was no difference in clinical outcome in diabetic patients, who were treated with SES versus RO-ZES. These findings may be considered as a signal of safety and efficacy of the studied DES in patients with diabetes. Data are n (%) or means ± SD. There were no significant differences between groups. Implications of small reference vessel diameter in patients undergoing percutaneous coronary revascularization Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia Coronary composition and macrophage infiltration in atherectomy specimens from patients with diabetes mellitus Short-and long-term results after multivessel stenting in diabetic patients Impact of diabetes mellitus on long-term outcomes in the drug-eluting stent era Very thin strut biodegradable polymer everolimus-eluting and sirolimus-eluting stents versus durable polymer zotarolimus-eluting stents in allcomers with coronary artery disease (BIO-RESORT): a three-arm, randomised, non-inferiority trial Thin composite wire strut, durable polymer-coated (Resolute Onyx) versus ultrathin cobalt-chromium strut, bioresorbable polymer-coated (Orsiro) drug-eluting stents in allcomers with coronary artery disease (BIONYX): an international, single-blind, randomised non-inferiority trial Ultrathin strut biodegradable polymer sirolimuseluting stent versus durable polymer everolimus-eluting stent for percutaneous J o u r n a l P r e -p r o o f coronary revascularisation (BIOSCIENCE): a randomised, single-blind, noninferiority trial Randomized comparison of a biodegradable polymer ultrathin strut sirolimus-eluting stent with a biodegradable polymer biolimuseluting stent in patients treated with percutaneous coronary intervention: the SORT OUT VII trial Everolimus-eluting versus Biolimuseluting stents with biodegradable polymers in unselected patients undergoing percutaneous coronary intervention: a randomized noninferiority trial with 1-year follow-up (SORT OUT VIII Trial) Safety and efficacy of a bioabsorbable polymer-coated, everolimus-eluting coronary stent in patients with diabetes: the EVOLVE II diabetes substudy Efficacy and safety of ultrathin, bioresorbable-polymer sirolimus-eluting stents versus thin, durable-polymer everolimus-eluting stents for coronary revascularization of patients with diabetes mellitus Five-year outcomes in patients with diabetes mellitus treated with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents