key: cord-0860808-2jmtuwma authors: Fontenla, Adolfo; Rodríguez-Muñoz, Daniel; Borrego-Bernabé, Luis; Montilla-Padilla, Isabel; Marco del Castillo, Álvaro; Ramos, Javier; Fernández-Arranz, Ana Isabel; López-Gil, María; Arribas, Fernando; Salguero-Bodes, Rafael title: Impact of Coronavirus Disease 2019 on Cardiac Arrhythmia Care: Experience of a Spanish Tertiary Hospital During the Health Crisis Triggered by the First Wave of the Pandemic date: 2021-09-15 journal: J Innov Card Rhythm Manag DOI: 10.19102/icrm.2021.120903 sha: 6d49cea477006f1611947bdda135fd849c0d6bba doc_id: 860808 cord_uid: 2jmtuwma The coronavirus disease 2019 (COVID-19) pandemic has resulted in a deep restructuring of cardiovascular care, especially in the setting of cardiac arrhythmia units, which are characterized by a wide variety of clinical and interventional activities. We describe the experience of a large university hospital deeply hit during the COVID-19 health crisis (first outbreak of the pandemic), focusing on the exceptional measures implemented and their impact in terms of outcomes. We performed a retrospective study comparing the human and structural resources and the activity of a cardiac arrhythmia unit in a Spanish tertiary hospital for two consecutive periods: from January 12, 2020, to March 8, 2020 (“pre-COVID stage”), and from March 9, 2020, to May 2, 2020 (“COVID stage”). Data were contextualized within the number of confirmed COVID-19 cases in the region of Madrid. The measures implemented were promotion of non–face-to-face consultations, selection of urgent procedures, design of a “COVID-free” circuit for outpatient interventions, and protocolization for patients with COVID-19. A total of 3,526 consultations and 362 procedures were performed. During the COVID stage, the number of consultations remained stable, and the electrophysiology rooms’ activity decreased by 55.2% with a relative increase in the number of urgent-hospitalized cases attended (11.8% COVID-19-positive patients). The electrophysiology rooms’ activity returned to “normal” in the last week of the COVID stage, with no contagion being detected among patients or professionals. In conclusion, the measures implemented allowed us to respond safely and efficiently to the health care needs of patients with arrhythmias during the COVID-19 crisis and may be useful for other institutions facing similar situations. During the last two years, the novel severe acute respiratory syndrome coronavirus 2, has spread worldwide, triggering a health crisis unprecedented in recent history. Transmitted through respiratory droplets, this virus is capable of causing coronavirus disease 2019 (COVID-19), sometimes producing severe and even fatal symptoms. 1 Old age, hypertension, obesity, diabetes, and cardiovascular diseases are risk factors for severe COVID-19, 2 affecting the majority of patients seen in cardiology departments. As a consequence of the first COVID-19 outbreak in Spain, there was a deep structural and functional reorganization at all health care levels with the aim of increasing the system's capacity during the period of highest demand for caring for COVID-19 patient care. All non-urgent activity of clinics, diagnostic tests, daytime hospitalization, scheduled admissions, and surgical interventions were suspended, directly impacting the organization of the arrhythmia units (as well as other intervention-based health care services). Consequently, adapting the activity of these units to the new scenario poses a challenge due to the high prevalence, mortality, and disability rates caused by cardiac arrhythmias and the need to address rhythm disorders in hospitalized patients with COVID-19. The aim of this paper was to describe the impact of the COVID-19 epidemic on the clinical management of the arrhythmia unit of one of the most deeply hit tertiary hospitals during the health care crisis that took place in March and April of 2020 in Madrid, the extraordinary measures implemented, and their performance in terms of outcomes. Hospital Universitario 12 de Octubre is a large third-level public university hospital in the Community of Madrid, which serves a population of around 500,000 inhabitants and has a usual inpatient census of 1,050. A retrospective descriptive and observational study was carried out where all data on health personnel management, clinics, and electrophysiology rooms dependent on the arrhythmia unit of Hospital Universitario 12 de Octubre (AUH12O) were collected during the 16 weeks between January 12 and May 2, 2020. The AUH12O attends two types of outpatient clinics: medical and nursing clinics. Prior to the pandemic, four medical clinics a week (three arrhythmia clinics and one general cardiology) were attended in person. Additionally, there were nine clinics a week for follow-up of cardiac devices (pacemakers, defibrillators, and implantable Holter monitors), attended by nurses in person or in a virtual format (using remote monitoring systems) supervised by medical staff. The AUH12O has two fully equipped intervention rooms for device implants, electrophysiological studies, and ablations, and an adjacent additional room for "simple" procedures (cardioversions, pharmacological tests, etc.). They are active for five morning shifts and three afternoon shifts per week. The procedures are performed on three types of patients: urgent hospitalized from the emergency department, hospitalized on a scheduled basis in conventional hospitalization beds, or in a day hospital (DH). A contingency plan for the AUH12O was developed in order to meet the health care needs of patients with arrhythmias in a safer manner, based on: (1) intensification of telehealth clinics; (2) cancellation of all non-urgent ambulatory procedures in favor of those that cannot be postponed; (3) scheduling of some outpatient procedures previously performed under hospitalization; (4) design of a "COVID-free" circuit for ambulatory patients; and (5) development of specific protocols for the management of patients with COVID-19 within the electrophysiology rooms. According to these changes, the analyzed period was divided into two stages: a "pre-COVID stage" from January 12 to March 8, 2020, and a "COVID stage" from March 9 to May 2, 2020. Data were contextualized within the pandemic situation considering the number of weekly COVID-19 infections confirmed in the region of Madrid. 3 Finally, in the case of patients operated on in the AUH12O during the COVID stage, planned telephone follow-up was performed to determine the appearance of complications and investigate the possibility of getting COVID-19 after the procedure by means of a specific questionnaire (see Supplementary Figure 1 online). Continuous variables are described as mean ± standard deviation values, and qualitative variables are described as absolute and relative frequencies (percentages). The latter were compared using the chi-squared test or Fisher's exact test when appropriate. A two-tailed p-value was calculated, considering two-tailed p-values of less than 0.05 as statistically significant. Various levels of adaptation of the AUH12O to the COVID-19 epidemic during the study periods are described as follows. The pre-COVID stage was based on a team of four fulltime electrophysiologists, two electrophysiology fellows, two residents, eight nurses, and three auxiliary nursing assistants. During the pandemic, the workforce was reduced due to the relocation of the two fellows, the two residents, one nurse, and one nursing assistant for the direct care of COVID-19 patients. The remaining personnel (68% of the initial workforce) took over the activities assigned to the AUH12O. In addition, during the first weeks of this stage, two nurses and one nursing assistant had to take sick leave and required home isolation as a consequence of COVID-19 presumably not acquired at work. Subsequently, staffing levels gradually returned to baseline in the last weeks of this study period. During the pandemic, telehealth was institutionally established as a priority with a double purpose: reducing the flow of patients throughout the hospital and promoting teleworking when possible among the employees. For this, some licenses were distributed, allowing physicians to access the electronic medical records system from their homes, enabling a virtual private network. Only those patients requiring a short physical examination or complementary test were attended to in person during the COVID stage. A total of 3,526 consultations were attended during the analyzed period (1,792 in the pre-COVID stage and 1,734 in the COVID stage), representing a reduction of 3.2% in the latter period. All consultations were recorded in the hospital's electronic medical records system. show the evolution of the activity of the outpatient clinics throughout the 16 weeks. There was a 150% increase in non-contact consultations, most especially during the last week of March, coinciding with the peak of assessed community transmission of COVID-19. As with conventional in-person consultations, test results were interpreted, electrocardiograms and reports from other centers sent via email were assessed, medication was electronically prescribed, new appointments were arranged, and complementary tests were requested when necessary. The performance of the clinics is shown in Table 1 . During the COVID stage, patients in clinical consultations continued to be discharged although in a lesser proportion than in the pre-COVID stage (66.6% vs. 49.4%; p < 0.001) and they continued to be included in the waiting list for device-related or electrophysiology procedures in a similar percentage (15.9% vs. 13.7%; p = 0.51). The impact of the COVID-19 epidemic in the arrhythmia intervention area during the central weeks of the COVID stage included the following measures: • Temporary closure of one of the electrophysiology rooms for five out of the eight weeks The following actions were carried out to guarantee access to invasive treatment of arrhythmias for patients who required it: • Selection of patients in need of preferential intervention, such as device generator replacements, ventricular tachycardia, or highly symptomatic supraventricular arrhythmias • Programming under the DH regime some ablations and device implants previously performed under standard hospitalization (given the use of the interventional DH facilities by the emergency department, a specific area Table 3 summarizes the characteristics of the six patients with COVID-19 who underwent procedures in the electrophysiology room during the study period (11.8% of urgent procedures). Three pacemaker implants, one defibrillator implant, one recurrent intra-nodal tachycardia ablation despite drugs, and one arrhythmic storm ablation (under general anesthesia) were performed. Four of these six patients were admitted to the emergency department as a result of an arrhythmia; the remaining two were admitted for COVID-19 pneumonia and developed arrhythmias during hospitalization. All interventions took place without incident. One of the hospitalized patients with pneumonia who received a pacemaker died two weeks later from respiratory failure. The rest were discharged. The personnel involved in these procedures did not develop COVID-19 nor had suggestive symptoms of the disease. The impact of the first outbreak of the COVID-19 pandemic on the health care activity of an arrhythmia unit in a university hospital in a severely affected region is described in this observational study. The main findings of the study are as follows: 1. The epidemic led to a one-third decrease in the human resources dedicated to the AUH12O and the activity interruption of one of the two electrophysiology rooms, as well as the afternoon shifts. 2. The measures to adapt the activity of the arrhythmia units to the pandemic, established on March 9, 2020, preceded the accelerated growth phase of the pandemic in the Madrid region and the rest of Spain, where a national shutdown was declared on March 14. 3. The impact of COVID-19 on the number of consultations was minimal (reduction of 3.2%), thanks to the significant increase in non-presential consultations (by 150%). Telephone attention was efficient, allowing for treatment adjustment, patient discharge, or their inclusion on the waiting list for arrhythmia procedures. 4. The interventions in the electrophysiology rooms were reduced by 55.2%, especially due to the restriction of procedures in the first three weeks of the outbreak, when the activity was limited to hospitalized patients admitted from the emergency department. 5. The implementation of specific protocols during the pandemic allowed for the safe performance of procedures on patients with COVID-19. 6. Weeks before, the population confinement measures were reduced, and in view of the decrease in health care pressure brought about by COVID-19, it was possible to progressively resume the programmed activities and "normal" functioning in the last week of the COVID stage. There were no suspected or confirmed COVID-19 infections among patients who underwent scheduled procedures. Our experience reveals that, in daily clinical practice, there is a chance to increase the proportion of telehealth consultations. This understanding may represent a paradigm shift in the organization of the activity of the outpatient clinics in arrhythmia units, as it provides obvious benefits in terms of costs, avoids the displacement of patients and their companions, limits the waiting times and physical occupation rates in clinics. These data suggest the need to empower telehealth for application not only in future epidemic outbreaks but also during periods of normal activity. In our opinion, arrhythmia units can take the opportunity induced by this crisis to decisively address the challenges posed by telemedicine at multiple levels (patient education, personnel management, computer equipment, remote monitoring platforms, video calls, wearable devices, etc.) in the context of what has been called the "digital revolution in health care" as a result of the COVID-19 pandemic. 4 During the study period, the need for planned interventions connected to the risk of contagion and the risk of Starting from a high individual risk in most of the patients on the waiting list, efforts were concentrated on limiting the risk of infection by ensuring direct access to the electrophysiology room through a "COVID-free" circuit and minimizing their hospital stay. Performing same-day discharge ablations and device implants is a previously described strategy that, in addition to being feasible and safe, generates patient satisfaction and reduces costs. [5] [6] [7] [8] The particularity of our approach to the problem was the development of a provisional DH within the area of cardiac interventionism, redistributing staff, given the occupation of the facilities of the interventional DH to support the emergency department and the extremely high occupancy of hospital beds, to where generator replacements, cardioversions, pacemaker and defibrillator implants, and certain ablations were performed. As in the case of telehealth clinics, this experience forced us to review the absolute need for hospital admission in many of the arrhythmia procedures, especially in times of uncertainty regarding the evolution of the pandemic. Although the definition of urgent procedures in arrhythmias can be complex, a selection was made in accordance with the previously reported document by the Heart Rhythm Society (HRS COVID-19 Task Force), which recommends postponing elective interventions in favor of those considered urgent or non-delayable. 9 There was also controversy about when elective interventions would be resumed after the peak of the pandemic, especially after the reported increase in mortality by 20% in patients undergoing scheduled surgeries. 10 Our group opted for an early resumption of scheduled activity, as the evidence regarding surgical interventions cannot be extrapolated to arrhythmia procedures, which are minimally invasive and require shorter hospital stays. This allowed a progressive reopening of elective activity in a safe manner during the week after following the local peak of the pandemic curve and minimizing the risk of scheduling interventions in coronavirus carriers through a telephonic epidemiological checklist (Supplementary Figure 1 ) and a prior PCR test in cases requiring hospitalization. The absolute number of urgent interventions in inpatients (hospitalized through the Emergency Department) was reduced by only 19% during the COVID stage, despite the limitations in personnel and availability of the electrophysiology rooms during the period. This decrease was less than that reported in other cardiology interventions such as percutaneous revascularization in acute myocardial infarction, whose activity in Spain was reduced by 40% during this crisis. 11 On the other hand, we experienced a significant increase in the proportion of urgent procedures at the expense of pacemaker implants. A recent observational study strongly suggested a higher mortality rate among patients hospitalized for COVID-19 with cardiac disease. 12 However, whether the outcomes of electrophysiological procedures are especially worse in these patients remains unclear. Although caution on this topic is needed in the absence of other reported series, our initial experience (a positive evolution of five out of six interventions in COVID-19 patients) does not suggest that they have a particularly unfavorable prognosis in this setting, and the results are probably directly related to the course of the infection itself. There are several publications by arrhythmia units proposing activity prioritization plans in electrophysiology rooms, 13 clinical pathways for managing patients with COVID-19 (suspected or confirmed), 14 and recommendations regarding the management of clinics and personnel restructuring. 15, 16 However, none of them provide data on the clinical results of the proposed measures. We report for the first time a comprehensive organizational experience in an arrhythmia unit during the COVID-19 outbreak, including planning, staff reordering, activity data, and clinical outcomes. The impact of the COVID-19 outbreak on our number of electrophysiology procedures was comparable to that published in similar countries like Italy, where a survey including 84 Italian arrhythmia units showed that most of them experienced a reduction in device implantations and cardiac ablations of more than 50%. 17 The main limitation of this study is that it was restricted to a single center. Although the measures implemented in the AUH12O during the pandemic are in line with the recommendations of scientific societies and the publications of other groups, they occurred in a particularly serious context, which may differ from other institutions. On the other hand, we lack an objective assessment of the performance of the actions taken in response to the epidemic, as we cannot compare our results with those of other series. The measures implemented in the AUH12O during the first outbreak of the COVID-19 pandemic in Spain helped to safely and efficiently adapt to the health care needs of patients with arrhythmias in this extraordinary situation. This experience can be useful when comparing the various The Journal of Innovations in Cardiac Rhythm Management, September 2021 strategies carried out during this period by other centers and with a look to the future planning of the arrhythmia units in future outbreaks of the pandemic. Our work may be useful when facing succeeding waves of COVID-19 in order to avoid the excess mortality indirectly caused by cardiac arrhythmias, guaranteeing the safety of the patients and the staff involved in cardiac care. Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study Clinical features of patients infected with 2019 novel coronavirus in Wuhan Daily notification of COVID-19 aggregate cases by the Spanish Ministry of Health. Madrid: Carlos III Health Institute Covid-19 and health care's digital revolution Feasibility and safety of same-day home discharge after radiofrequency catheter ablation Feasibility and safety of same-day discharge after implantable cardioverter defibrillator placement for primary prevention Safety of outpatient implantation of the implantable cardioverter-defibrilator Same-day discharge in selected patients undergoing atrial fibrillation ablation Guidance for cardiac electrophysiology during the coronavirus (COVID-19) pandemic from the Heart Rhythm Society COVID-19 Task Force; Electrophysiology Section of the American College of Cardiology; and the Electrocardiography and Arrhythmias Committee of the Council on Clinical Cardiology Clinical characteristics and outcomes of patients undergoing surgeries during the incubation period of COVID-19 infection Impact of the COVID-19 pandemic on interventional cardiology activity in Spain Characteristics and outcomes of patients hospitalized for COVID-19 and cardiac disease in Northern Italy Priority plan for invasive cardiac electrophysiology procedures during the coronavirus disease 2019 (COVID-19) pandemic COVID-19 pandemic and cardiac electrophysiology: guidance protocol from a UK tertiary cardiac center Performance of electrophysiology procedures at an academic medical center Restructuring electrophysiology during the COVID-19 pandemic: a practical guide from a New York City hospital network Impact of COVID-19 pandemic on the clinical activities related to arrhythmias and electrophysiology in Italy: results of a survey promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing) The authors report no conflicts of interest for the published content. Manuscript received December 24, 2020. Final version accepted March 23, 2021.