key: cord-0856267-xrwq7etq authors: Adwibowo, A. title: Computational fluid dynamic (CFD), air flow-droplet dispersion, and indoor CO2 analysis for healthy public space configuration to complywith COVID 19 protocol date: 2020-07-06 journal: nan DOI: 10.1101/2020.07.02.20145219 sha: 1debaa10c36d36bcbe546bbd595761446b59f991 doc_id: 856267 cord_uid: xrwq7etq The droplet has a limited travel distance. Nonetheless, especially in the indoor public space the air flow can propagate the droplet to travel long distance. Based on this situation, this paper aims to study the relationships of seat configuration-social distance-air flow-droplet dispersions. The analysis was based on the computational fluid dynamic (CFD) using lattice Boltzmann model (LBM). The result confirms that by modifying public space configuration in this case by providing more space and increasing seating distance can reduce the vulnerability towards droplet dispersions. Whereas, providing shield including adding protection is far more effective in avoiding dispersions. The public space reconfiguration including increasing seat distance and reducing seating capacity also has an effect in reducing the indoor CO2. Capacity reduction from full capacity to 30% can decrease the CO2 from 5722 to 2144 ppm. The control is the default seating configuration without shield and no distance as well. While, the scenario includes the seating configuration with distance and seating arrangement provided with protective shield. The CFD model of particle flows across the barriers is using the lattice-Boltzmann method (LBM). This method has been widely used to study the air flow and suitable for indoor setting (Crouse et al. 2002 , Khan et al. 2015 . The LBM based on threefold discretization of the Boltzmann equation including phase space, involving space, time, and velocities. The movement and distributions of a flow particle . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 6, 2020. . https://doi.org/10.1101/2020.07.02.20145219 doi: medRxiv preprint are described by particle distribution functions residing at the sites of a regular grid (lattice) of points which encompasses an entire indoor environment including a room. The particle distribution functions represent the particle presence probability with a given velocity at each lattice site. The lattice is given as follow equation: Using model in Figure 1 , a discretize twodimensional space with a square lattice is developed. In this model, 9 fundamental displacements and velocities were also developed. The model was completed using simulation variables n i consist of 9 densities at each lattice of particles with the 9 allowed velocities. Then, a total density ρ and macroscopic flow velocity µ are denoted as: Particle in axis x is denoted as: Particle in axis y is denoted as: Figure 2 ,3, and 4 present the air flow across the seating configuration. The air flow direction was modeled from the front side. There were 3 scenarios were developed, they were seating configuration without distance and protective structure, with distance, and with protective structure. The seating configuration was classroom configuration with several rows. This is the general configuration that is commonly used in the school, teaching theatre, and even transportation facility including bus and plane. In the first scenario ( Figure 2 ), it shows that the air flow can reach and very close to the second and third rows. The second and third rows were arranged at standard distance. The second scenario ( Figure 3) shows that there was an increased distance between rows. As a result, there was a space between the air flow and second row and it was obvious for the third row. The third scenario (Figure 4 ) was the scenario when there is no distance between rows. Nonetheless, a shield was installed to border row. The aim of shield installment is to observe whether the shield can obstruct the air flow. The results showed that the second and third rows were free from air flow. The shield can obstruct the air flow and the air is flowing above the second and third rows. This paper also tested the indoor CO 2 production under seat capacity. Increasing is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 6, 2020. . https://doi.org/10.1101/2020.07.02.20145219 doi: medRxiv preprint seating distance means reducing number of seat available in a classroom. Figure 5 and 6 shows the indoor CO 2 production under different numbers of seating capacity (30% to full) and outdoor CO 2 . It clears that the indoor CO 2 has positive correlation with the seat capacity. Reducing seating capacity can reduce the indoor CO 2 . Air flow direction chair . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 6, 2020. . Air flow direction . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 6, 2020. . https://doi.org/10.1101/2020.07.02.20145219 doi: medRxiv preprint A behavior and dynamic of air flow with its particle contained have led to numerous researches using CFD approaches. A CFD work to investigate the indoor air quality has been pioneered by Yang et al (2003) . In their paper . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 6, 2020. . https: //doi.org/10.1101 //doi.org/10. /2020 unit was carried by the air to people at other tables. This model indicates that the air flow released from ventilation unit can be distributed to other areas. In indoor settings, virus transmission could not have been by respiratory droplet transmission alone, whereas a stronger air flow produced from air conditioned ventilation unit is also responsible to spread the droplets (Ezratty and Squinazi 2008 , Prussin et al. 2016 , Goyal et al. 2008 . A crowded place with no distance seating configuration is also an evidence of dispersion in indoor public space. According to Park et al. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 6, 2020. . https://doi.org/10.1101/2020.07.02.20145219 doi: medRxiv preprint It has been discussed that the social distancing and wearing protection including face mask and shield can reduce the vulnerability to droplet dispersion. Likewise, this paper has provided an empirical study how those measures can be effective in avoiding the droplet dispersion. In a classroom setting, maintaining seating configuration by reducing seating capacity and even adding protective structure can be an effective measure to reduce and avoid droplet dispersions and even increase air quality. Modifying the current public space configuration and capacity can be an option to effectively reduce the droplet dispersion and transmission rates. Following to that, it is recommended that the decision and strategy regarding the public space arrangement should be based on empirical study using robust model and CFD can be the option. Covid-19: The Preventive Protocol for Educational Institutions Indoor air flow analysis based on lattice Boltzmann methods Pandemic influenza virus inside buildings: Is there a risk of transmission by ventilation or air conditioning systems