key: cord-0855650-x9fhar2o authors: Shinohara, Naohide; Sakaguchi, Jun; Kim, Hoon; Kagi, Naoki; Tatsu, Koichi; Mano, Hiroyuki; Iwasaki, Yuichi; Naito, Wataru title: Survey of air exchange rates and evaluation of airborne infection risk of COVID-19 on commuter trains date: 2021-07-23 journal: Environ Int DOI: 10.1016/j.envint.2021.106774 sha: 29da4d9dc78cbe718839ee28cd365772908eb2c7 doc_id: 855650 cord_uid: x9fhar2o To identify potential countermeasures for coronavirus disease (COVID-19), we determined the air exchange rates in stationary and moving train cars under various conditions in July, August, and December 2020 in Japan. When the doors were closed, the air exchange rates in both stationary and moving trains increased with increasing area of window-opening (0.23–0.78 /h at 0 m(2), windows closed to 2.1–10 /h at 2.86 m(2), fully open). The air exchange rates were one order of magnitude higher when doors were open than when closed. With doors closed, the air exchange rates were higher when the centralized air conditioning (AC) and crossflow fan systems (fan) were on than when off. The air exchange rates in moving trains increased as train speed increased, from 10/h at 20 km/h to 42/h at 57 km/h. Air exchange rates did not differ significantly between empty cars and those filled with 230 mannequins representing commuters. The air exchange rates were lower during aboveground operation than during underground. Assuming that 30–300 passengers travel in a train car for 7–60 min and that the community infection rate is 0.0050%–0.30%, we estimated that commuters’ infection risk on trains was reduced by 91%–94% when all 12 windows were opened (to a height of 10 cm) and the AC/fan was on compared with that when windows were closed and the AC/fan was off. breathing, talking, coughing, and sneezing. Large droplets (mostly larger than a few tens of micrometers in diameter) are deposited rapidly onto the floor within a distance of 2 m from the infected persons, whereas small droplet nuclei (i.e. the residue of dried aerosols that result from the evaporation of droplets; mostly smaller than several micrometers in diameter) can remain suspended in air for more than 1 h before deposition or air exchange (Wells 1934; Xie et al. 2007) . Whereas larger droplets are removed from indoor air predominantly through their deposition on floors and walls, small droplet nuclei are removed primarily thorough air exchange (Yang and Marr, 2011) . By definition, droplet transmission is accomplished through the direct deposition of droplets onto mucosae or conjunctiva and their inhalation; airborne transmission is due to the inhalation of droplet nuclei; and contact-based transmission arises after contact with a polluted surface and the transfer of virus to the mucosae or conjunctiva via touching the eyes, nose, and mouth (WHO, 2020; . Bourouiba et al. (2021) , who reviewed the fluid dynamics of disease transmission, emphasized the importance of the size and nature of inhaled particles to understand range and evolution of the droplet nuclei and their ability to penetrate deep into the respiratory tract. The biological plausibility of airborne transmission can be rated according to three factors: generation of pathogen containing aerosol, its viability in the environment, and its access to target tissue (Jones and Brosseau, 2015) . The biological plausibility of airborne transmission with SARS-CoV-2 has been rated as high because the air surrounding COVID-19 patients contains viable SARS-CoV-2, because SARS-CoV-2 remains viable in aerosol for a certain period of time, and because SARS-CoV-2 can directly reach its receptor, angiotensin-converting enzyme 2 (ACE 2), in the respiratory tract and alveoli (Tang et al. 2021) . In particular, although viruses in aerosol generally become inactivated over time, SARS-CoV-2 is persistent for a certain period of time (median viability, 1.1 h; 95% confidence interval, 0.6-2.6 h) ). Virus transmission from large droplets (droplet transmission) can be prevented through the appropriate use of face masks, protective shields, and social distancing. Ventilation is a critical countermeasure to transmission through droplet nuclei (airborne transmission). Numerous studies have measured air exchange rates in buildings as a first step towards decreasing the exposure to volatile chemicals and particulate matter in indoor air (Beko et al. 2010; Shinohara et al. 2011; 2013) . Although computational fluid dynamics (CFD) calculations are used to estimate air exchange rates and the diffusion of droplet nuclei (Asai et al. 1995; Wand et al. 2014; Li et al. 2019 ), these factors have not been surveyed on commuter trains. Many studies have indicated possible airborne transmission of COVID-19 (Tang et al., 2021) in various environments, such as on a bus and in a restaurant (Li et al., 2021) . Dose-response model and Wells-Riley model have both been used to estimate the airborne infection risk . A dose-response model is based on the amount of exposure to the virus, obtained through measurements or simulations, and a dose-response curve, obtained from an epidemiological study or animal test. The doseresponse model can be applied simultaneously to multiple exposure pathways (Haas et al., 1983; Nicas and Sun, 2006; Nicas and Jones, 2009; Haas, 2014) , and the model have used to estimate the risk of COVID-19 for healthcare workers (Mizukoshi et al., 2021) and for individual participants of mass-gatherings (Murakami et al., 2021) . The Wells-Riley model, which is specific to estimating airborne infection risk, is based on quanta generation rates, which are collected from epidemical studies, and dilution factors (air exchange rates and deposition rates), which are obtained through measurements or simulations (Riley et al., 1978) . Quanta generation rates Dai and Zhao, 2020; Miller et al., 2020) and airborne infection risks (Harrichandra et al., 2020; Schijven et al., 2020) for COVID-19 have been evaluated. The basic reproductive number (R 0 ) for COVID-19 can be decreased by reducing the commute time and number of passengers on buses (Chen et al., 2021) . However, no previous study has evaluated the risk reduction for COVID-19 associated with improved ventilation and window-opening in vehicles. Here, we determined the air exchange rates on commuter train cars in Japan under several conditions, to understand the effects of potential countermeasures against COVID-19. Then, we estimated the airborne infection risk of COVID-19 by using a doseresponse model with the measured air exchange rates and assumed community infection rates, commute time, and number of passengers. During 3 periods in 2020 (17-19 July, 14-16 August, and 11-13 December), we determined the air exchange rates in a commuter train (Tokyo Metro Series 16000). Each train comprised 10 cars; each car had a total volume of 107.1 m 3 and had seats for 54 passengers, 12 windows that could be opened, and 8 doors. Four air intakes for the air conditioner (AC) are placed on both sides of the ceiling over benches, and outlet along each side of ceiling ( Figure 1 ). Crossflow fans are placed at the center of ceiling ( Figure 1 ) blow air downwards and towards the wall. A ventilation system is not installed because it requires frequent maintenance owing to the particles in air in the underground tunnel. Of the 10 cars, we used the 3rd and 8th cars for measuring air exchange rate because these cars do not have underfloor equipment that generates heat, such as a motor. Stationary tests were conducted at Ayase Depot (Adachi, Tokyo, Japan). Moving tests were conducted aboveground between Ayase-and Kitasenju-stations (2.5 km) and underground between Kitasenju-and Kasumigaseki-stations (12 km). Air flow velocity was measured in the 3rd car, and airtightness was measured in the 5th car. The air exchange rates were measured by using the CO 2 decay method (JIS, 1974; ASTM, 1998) , which is appropriate for determining short-term air exchange rates in unoccupied rail cars. In brief, CO 2 was emitted from gas cylinders into the cars. Indoor air was agitated by using circulators (EAC-23-W, Iris Ohyama Inc., Sendai, Japan) and blowers (Earthman BW-144LiAX, Takagi Co., Ltd., Kitakyushu, Japan) until the CO 2 concentrations reached equilibrium across all 21 sampling points in the cars. Then, the indoor CO 2 concentration was monitored every 10 s at all sampling points in each car ( Figure 1 ) at heights of 1.5 m (representing standing passengers) and 1.2 m (0.7 m from the seat surface; representing seated passengers) for 15 min to 2 h with a CO 2 monitor (MCH-383SD, Lutron Electronic Enterprise Co., Taipei, Taiwan, or TR-76Ui, T & D Co., Matsumoto, Japan). The outdoor CO 2 concentration was measured before and after each in-car CO 2 measurement. Before each period of the survey (July, August, and December), the CO 2 monitors were calibrated against several concentrations of CO 2 gas, including ambient level, according to a calibrated CO 2 monitor (Model 2211, Kanomax Japan, Inc., Osaka, Japan). The air exchange rates were obtained by fitting exponential functions to the differences of CO 2 concentrations between inside and outside of the cars. Stationary tests were conducted in a closed train depot with negligible wind. In the During August 2020, air flow velocity (10-s average) in the 3rd car was measured at 4 points every 10 s with a multi-channel thermal anemometer with a platinum wire OMAT2000, EOM Co., Shizuoka, Japan). To assess the airtightness of the cars, the equivalent leakage area per floor area (C-value) was calculated by dividing the total area of any gaps by the total floor area, which included the seating surface. We estimated the airborne infection risk of COVID-19 for passengers on commuter trains that was attributable to inhalation of droplet nuclei under several conditions by varying community infection rate, number of passengers on the train, commute time, AC/fan on or off, and exposure to infected persons who were talking or silent. We did not estimate droplet transmission due to direct deposition on mucosae or conjunctiva or to inhalation of large droplets, because almost all commuters in Japan have worn masks, which exclude large droplets, since winter 2020; therefore, the occurrence of droplet transmission on commuter trains in Japan was minimal. In addition, we did not estimate contact-base transmission, because viral copies of SARS-CoV-2 were not detected at high concentrations on surfaces even in rooms inhabited by infected persons (Yamagishi et al. 2020 ). The concentration of virus to which a passenger in commuter train was exposed was estimated by using two-zone (i.e., near-field and far-field) model (Spencer and Plisko, 2007) . We assumed that passengers in both the near-field and far-field of an infected person were exposed to virus contained in droplet nuclei that originated from that person ( Figure S2 ). Although some passengers could expose to droplet nuclei exhaled from multiple infectors when multiple infectors ride on the train car, we assumed that nearfields did not overlap with each other to simplify the calculation. The two-zone model (Spencer and Plisko, 2007) was expressed as: Near-field: Far-field: where C near_m (t) and C far_m (t) (plaque-forming unit [PFU]/m 3 ) are the concentrations of virus in the near-field and far-field, respectively, in the train car when m infected persons (i.e. infectors) are present; E (PFU/h) is the rate of virus emission from an infector; F (m 3 /h) is the air flow volume rate from the near-field to the far-field and from near-field to far-field; I (m 3 /h) is the inhalation rate of a commuter; d inhalation (unitless) is the deposition fraction in alveoli, conducting airways, and head airways; λ, N, and d (/h) are the inactivation rate, air exchange rate, and deposition rate on indoor surfaces, respectively; V near , V far_m , and V (m 3 ) are the estimated near-field volumes, far-field volumes, and total indoor volume of the train car; and n near and n far_m (unitless) are the expected number of commuters in a near-field and a far-field, respectively. The near-field was set as an ellipsoid (semi-minor axis, 0.25 m; semi-major axis, 0.5 m) in front of the infector. The expected numbers of commuters in the near-field and far-field (n near and n far_m ) were assigned according to the ratio of the projected area of the near-field to the floor and the rest area of the floor. The air completely mixed in the near-field was assumed to exchange with the air completely mixed in the far-field through half of the surface area of the ellipsoid according to the indoor air flow velocity (Spencer and Plisko 2007) . The in-car air flow velocity with the AC/fan off during the stationary test was substituted for the in-car air flow velocity with the AC/fan off while the train was moving because the in-car air flow velocity with the AC/fan on did not differ between stationary and moving tests ( Figure S6 ). The number of viruses in the droplet nuclei generated during breathing and talking was assumed to be equal to that in the original droplets, wherein the virus concentration is assumed to be equal to that in the saliva. The infection risk for a commuter in the near-field and far-field when m infectors are in the train car, R near_m and R far_m (unitless), respectively, can be expressed thorough the following equation, which is based on the general exponential model (Nicas and Jones, 2009; Watanabe et al., 2010; Haas et al., 2014) : where k (/PFU) is the dose-response function for SARS-CoV-2, I (m 3 /h) is the inhalation rate of a passenger, t c (h) is the commute time of the infector, and C near_m (t) and C far_m (t) (PFU/m 3 ) are the estimated exposure concentrations of the virus in the near-field and farfield when m infectors are present. When we consider the community infection rate, the infection risk in the train car, R train , can be expressed by using a binomial distribution as: where i (unitless) is the maximum number of infected individuals on the train (m), r (unitless) is the community infection rate, and n (unitless) is the total number of commuters in the entire train (n = m n near + n far_m ). Because there is little additional contribution from i when i > 5, the calculation was approximated using i ≤ 5. The parameters and parameter derivation methods are listed in Table 1 . Because of the public need for a rapid report, the air exchange rate data from the August 2020 survey are available in part on the website of the National Institute of Advanced Industrial Science and Technology (AIST, 2020). Representative CO 2 concentration decay profiles are shown in Figure S3 . Average air exchange rates were higher when the AC/fan was on than when it was off during the July test ( Figure 2 ). The variation in the air exchange rates (mean ± SD) among positions in the car was lower when the AC/fan was on (5.5% ± 4.4% in July, 3.2% ± 0.99% in August, and 7.2% ± 4.2% in December) than when it was off (20% ± 8.7% in July, 25% ± 17% in August, and 11% ± 5.8% in December). In the stationary tests, air exchange rates were positively correlated with the absolute value of the indoor-outdoor temperature difference ( Figure S4 ). However, they were more strongly correlated with the window-opening area (Figure 2 ). Air exchange rates were similar whether the 230 mannequins were present or not ( Figure S5 ). In The Error bars show SD of the air exchange rates obtained from all 21 sampling points. During stationary tests with doors closed, the air flow velocity was similar regardless of the window-opening area. Air flow velocities were higher when the AC/fan was on (average, 0.21 m/s) than when it was off (average, 0.0088 m/s; Figure S5 ). They were higher when doors were open (0.38 and 0.034 m/s for AC/fan on and off, respectively), but did not related to the window-opening area ( Figure S6 ). When the train was moving, air flow velocities with the AC/fan on were 0.19-0.31 m/s and did not differ with train speed ( Figure S6 ). The total leakage area of the car was 299 cm 2 and the C-value (gap area per floor area) was 5.4 cm 2 /m 2 . Estimated virus concentrations in the car are shown in Figures S7 and S8 . Representative estimated risks of COVID-19 infection in the near-field and far-field are shown in Figure S9 . Table S1 ). Assuming that 30-300 passengers traveled on trains for 7-60 min in the context of a community infection rate of 0.0050%-0.30%, the risk of airborne infection risk in a train car (R train ) was estimated to be reduced by 91%-94% when windows were open (12 windows each open to 10 cm) and the AC/fan was on compared with when windows were shut and the AC/fan off (Table S1) . Despite their importance for deriving countermeasures to COVID-19, air exchange rates in commuter trains have not been reported to date. We found that the air exchange rates in stationary train cars were strongly correlated with the window-opening area. In residential houses, the duration and degree of window-opening were strongly associated with air exchange rates (Shinohara et al., 2011; Hou et al., 2018) . CFD calculations and wind tunnel experiments demonstrated that air exchange rates were related to the window-opening area (Larsen and Heiselberg, 2008) . In buildings, the natural ventilation volume is well known to be correlated with the window-opening area (Kurabuchi, 2020) . Therefore, the natural ventilation of trains can be considered similar to that of buildings. In the present study, the stationary tests were conducted in the depot, with its shutters, doors, and windows closed, so the effect of wind outside the train was negligible. Previous CFD calculations and wind tunnel experiments have indicated that air exchange rates increase when the wind speed is high, especially when the wind direction is perpendicular to the windows (Gratia et al., 2004; Larsen and Heiselberg, 2008) . Therefore, the air exchange rates we obtained may increase if the outdoor wind direction and speed recapitulate those in a real-world station environment. The air exchange rates in train cars were correlated with the indoor-outdoor temperature difference. Previous CFD calculations and wind tunnel experiments demonstrated that the air exchange rates varied depending on indoor-outdoor temperature differences when the wind direction was parallel to windows or the wind speed was null (Gratia et al., 2004; Larsen and Heiselberg, 2008) . In addition, the relative effect of the temperature difference on air exchange rates decreased when the outdoor wind speed increased (Larsen and Heiselberg, 2008) . Because our study was conducted in a closed train depot in still air, the obtained air exchange rates were related to the indoor-outdoor temperature difference. In the December survey, the air exchange rates remained similar regardless of whether the heater was on or off. In the survey, temperature differences were similar between the heater-on and heater-off conditions probably because of the short test interval and the relatively high in-car temperature even with the heater off. Under real-world conditions, the temperature differences and thus air exchange rates might decrease when the heater is off. The air exchange rates with the doors closed were higher with the AC/fan on than off. Air exchange rates in buildings are increased when the outdoor wind speed is high (Gratia et al., 2004; Larsen and Heiselberg, 2008) . The air exchange rates may depend on in-car air-flow velocity; indeed, they were substantially higher when the AC/fan was on than when it was off. By contrast, air exchange rates when the doors were open were higher with the AC/fan off, perhaps because of non-uniformity of in-car under these conditions. During tests while the train was moving, the air exchange rates depended on the train speed, which may exert the same effects as those of wind speed. Furthermore, the air exchange rates were lower when the train was running aboveground rather than underground. This result might reflect differences in the indoor-outdoor air pressure, which were larger underground than aboveground (data not shown). When air exchange rates were equal, the air exchange volume in the train car with mannequins was 11% lower than that without mannequins owing to the volume of the mannequins (12 m 3 ) relative to that of an empty car (107 m 3 ). In addition, the air exchange volume might decrease further in the presence of passengers owing to inhibition of air flow. The decrease in the air exchange volume in the train with 230 mannequins was observed to be only 15% compared to that without mannequins in the present study. It indicated that the presence of the mannequins did not significantly affect the air exchange volume. However, the upward current due to the heat generated by passengers, transfer of air caused by passenger flow, and air disturbance caused by passengers talking and breathing might all affect air exchange rates. Therefore, these effects should be elucidated in future studies. The C-value of the train cars (5.4 cm 2 /m 2 ) was much higher than that measured in residential houses (0.16-0.63 cm 2 /m 2 ; Ikehara and Sakai, 2018) . From both functional and structural viewpoints, the interior of the train car had many gaps. The total leakage area of the car determined in the airtightness test (0.029 m 2 ) was smaller than that assumed from the intercept of the regression line of the air exchange rates and windowopening area (approximately 2 m 2 ). One possible cause of this difference is that the airtightness test directly determines the serial composition of the inlet and outlet gap areas, whereas the inlet gap areas might be calculated from measurements of the air exchange rates. The gaps in the inside walls of train car, which is more likely to influence air exchange rates, were much larger than the gaps in the outside wall, which is associated with airtightness. Another cause might be the inaccuracy in the airtightness test, which revealed small differences in air pressure between inside and outside of the car in the present study. Because we used a passive CO 2 monitor, rather than active monitor that aspirated air by pump, there was a delay in the response time. Therefore, larger air exchange rates may be underestimated. However, there was no reversal of the large and small relationship of the air exchange rates. Recent case-control research has indicated that the use of public transport-unlike dining in restaurants and going to bars or coffee shops-did not increase the risk of COVID-19 infection (Mark et al. 2021 ). To gauge the uncertainty in the assumed volume of the near-field, when we calculated the risk by 10-fold increase the volume with the same shape (major radius increased from 0.50 m to 1.1 m), the infection risk of a passenger in near-field (R near_1 ) decreased by 93% (5.9×10 -6 ) with the windows closed and the AC/fan off and by 92% volume rate from near-field to far-field, we calculated the risk associated with a 3-fold increase and one-third reduction in air flow volume. Consequently, the airborne infection risk in a train car (R train ) decreased by 62%-65% and increased by 2.6-to 2.9-fold, respectively, when windows were closed and the AC/fan was off and decreased by 48%-63% and increased 2.1-to 2.5-fold, respectively, when the windows open and the AC/fan was on. The risk reduction associated with open windows and the AC/fan on did not differ markedly (0.89%-6.4%) under these theoretical changes in air flow. We did not estimate the droplet infection risk because most commuters in Japan currently wear masks and avoid speaking loudly on trains. The risk might increase when some passengers talk loudly or do not wear masks. In addition, although viral copies were not detected at high concentrations on surfaces even in rooms inhabited by infected persons, and even though viable viruses were detected only rarely (Yamagishi et al. 2020 ), contact-based transmission by SARS-CoV-2 while commuting by train may not be ruled out. Estimating the risks associated with these transmission routes should be the subject of future research. Furthermore, opening the windows on moving train presents concerns regarding the risk of exposure to outdoor pollutants, noise, summer heat, and winter cold and merits risk-tradeoff analysis. One limitation of the risk evaluation in the present study is related to the doseresponse curve. We used the dose-response curve for mice death with SARS-CoV as an alternative for human infection with SARS-CoV-2. Although the basic reproduction number (R 0 ) of SARS-CoV-2 was similar to that of SARS-CoV (Mizukoshi et al., 2021) , it would be preferable to estimate risk by using the dose-response curve for SARS-CoV-2 when it becomes available. Regardless, using a mouse death dose-response relationship as a surrogate for an unavailable infection human dose-response relationship is generally accepted in human infection risk studies (Haas et al., 2014; Mizukoshi et al., 2021) . During stationary tests, the air exchange rates in train cars were strongly correlated with the window-opening area and weakly correlated with indoor-outdoor temperature differences. When doors were closed, air exchange rates were higher when the AC/fan was on than when it was off. Air exchange rates were much higher when doors were open than when closed. During tests of moving trains, air exchange rates in cars were strongly correlated with the train speed. By opening windows and turning on the AC/fan, commuters' infection risk in trains may be reduced by 91%-94%. A risk-tradeoff analysis with the window-opening-which decreases virus exposure but increases exposure to outdoor pollutants, noise, and heat or cold-is warranted. The effectiveness of air purifiers and AC filters as alternatives to window-opening should be evaluated as well. The authors declare no competing financial interest Efficacy of ventilation in subway vehicle including window opening Inhalation rates. The Japanese Exposure Factors Handbook. National Institute of Advanced Industrial Science and Technology ASTM: America Society for Testing and Materials. ASTM D6245: Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation Ventilation rates in the bedrooms of 500 Danish children The Fluid Dynamics of Disease Transmission Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment Estimation of the SARS-CoV-2 transmission probability in confined traffic space and evaluation of the mitigation strategies. Environmental Science and Pollution Research Association of the infection probability of COVID-19 with ventilation rates in confined spaces How to use natural ventilation to cool narrow office buildings Quantitative microbial risk assessment 2nd ed Estimation of risk due to low doses of microorganisms: a comparison of alternative methodologies An estimation of airborne SARS-CoV-2 infection transmission risk in New York City nail salons Air change rates at night in northeast Chinese homes Study and Assessment on the Airtight Performance of Dwelling Units in Newly Built Apartment Buildings JIS-1406: Method for Measuring Amount of Room Ventilation (Carbon Dioxide Method) Aerosol Transmission of Infectious Disease Architecture course for beginners -Building Environment Single-sided natural ventilation driven by wind pressure and temperature difference Multi-objective optimization for designing of high-speed train cabin ventilation system using particle swarm optimization and multi-fidelity Kriging Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant Identifying COVID-19 Risk Through Observational Studies to Inform Control Measures Views on measures against COVID-19, Novel Coronavirus Expert Meeting Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event SARS: Dose response experiments. QMRA Wiki web sites Assessing the risk of COVID-19 from multiple pathways of exposure to SARS-CoV-2: Modeling in health-care settings and effectiveness of nonpharmaceutical interventions Metropolitan transportation census in Tokyo metropolitan area. Ministry of Land, Infrastructure, Transport and Tourism Congestion rates of major sections in Tokyo metropolitan area at 2019. Ministry of Land, Infrastructure, Transport and Tourism Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities Respiratory disease in rhesus macaques inoculated with SARS-CoV-2 Microbial Risk Analysis An integrated model of infection risk in a health-care environment Relative Contributions of Four Exposure Pathways to Influenza Infection Risk Airborne spread of measles in a suburban elementary school Multiple path particle dosimetry model (MPPD v.3.04): a model for human and rat airway particle dosimetry Quantitative Microbial Risk Assessment for Airborne Transmission of SARS-CoV-2 via Breathing, Speaking, Singing, Coughing, and Sneezing Community Outbreak Investigation of SARS-CoV-2 Transmission Among Bus Riders in Eastern China Distribution and variability of the 24-h average air exchange rates and interzonal flow rates in 26 Japanese residences over 5 seasons. Atmospheric Environ Indoor air quality, air exchange rates, and radioactivity in new built temporary houses following the Great East Japan Earthquake in Minamisoma Evaluation of a mathematical model for estimating solvent exposure in the workplace Aerosol transmission of SARS-CoV-2? Evidence, prevention and control Review and comparison between the Wells-Riley and doseresponse approaches to risk assessment of infectious respiratory diseases Consistent detection of the 2019 novel coronavirus in saliva Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during SARS-CoV-2 infection: An observational cohort study Route/Station Information Changes in Population, 2. Population and Households. Tokyo Statistical Yearbook Change in positive cases by reported day. Updates on COVID-19 in Tokyo. COVID-19 Information Website. 2021 Prediction and countermeasure of virus droplet infection in indoor environment Comparing the analytical performance of three SARS-CoV-2 molecular diagnostic assays Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1, New Eng Performance evaluation of air distribution systems in three different China railway high-speed train cabins using numerical simulation Development of a dose-response model for SARS coronavirus On airborne infection. Study II. Droplet and droplet nuclei Director-General's opening remarks at the media briefing on COVID-19 -March 11, 2020. World Health Organization COVID-19) Dashboard; World Health Organization Virological assessment of hospitalized patients with COVID-2019 Saliva or nasopharyngeal swab specimens for the detection of SARS-CoV-2 How far droplets can move in indoor environments -revisiting the Wells evaporation-falling curve, Indoor air Outbreak on the Diamond Princess Cruise Ship Thermal effect of human body on cough droplets evaporation and dispersion in an enclosed space Dynamics of airborne influenza A viruses indoors and dependence on humidity Commuters' infection risk on trains was reduced by 91%-94% with windows open and AC/fan on Credit authorship contribution statement Project administration, Conceptualization, Methodology, Survey, Data analysis, Validation, Visualization, Writing original draft, Writing -review & editing. Jun Sakaguchi: Methodology, Survey, Writing -review & editing. Hoon Kim: Methodology, Survey -review & editing. Naoki Kagi: Methodology, Survey, Writingreview & editing. Koichi Tatsu: Methodology, Survey -review & editing. Hiroyuki Mano: Survey -review & editing. Yuichi Iwasaki: Survey -review & editing. Wataru Naito: Conceptualization, Methodology We would like to express our gratitude to Tokyo Metro Co., Ltd. for providing the measurement environment and Taiyokogei Co., Ltd. for providing the mannequins for this study. We would like to express our gratitude to Mr. Akihiro Nagao from Espec Co.,Ltd., Mr. Yasuhiko Ota from Isuzu Advanced Engineering Center, Ltd., and Mr. Isao Uchiyama, Mr. Hoshino Kunihiro, Mr. Taizo Higashiyama, Mr. Keisuke Hayakawa, and Mr. Futoshi Yoshimura from Kanomax Japan, Inc., for the assistance in the survey. ☒ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.☐The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: