key: cord-0851658-pxaoh8gj authors: Tarka, Patryk; Borowska-Solonynko, Aleksandra; Brzozowska, Małgorzata; Nitsch-Osuch, Aneta; Kanecki, Krzysztof; Kuthan, Robert; Garczewska, Barbara title: No-Touch Automated Room Disinfection after Autopsies of Exhumed Corpses date: 2020-08-12 journal: Pathogens DOI: 10.3390/pathogens9080648 sha: 7dcc9b4f78b25510bb895db35027742f9c3274f4 doc_id: 851658 cord_uid: pxaoh8gj Autopsies of exhumed bodies pose a risk of infections with environmental bacteria or fungi, which may be life-threatening. Thus, it is important to use effective methods of disinfection in forensic pathology facilities. In this study, we investigated the effectiveness of no-touch automated disinfection (NTD) system after autopsies of exhumed bodies. Directly after 11 autopsies of exhumed bodies, we used an NTD system based on a peroxone vapor to disinfect the air and surfaces. We measured microbial burden in the air and on surfaces before and after NTD. The NTD system reduced the mean bacterial burden in the air from 171 colony forming units (CFU)/m(3) to 3CFU/m(3). The mean fungal burden in the air decreased from 221 CFU/m(3) to 9CFU/m(3). The mean all-surface microbial burden was 79 CFU/100 cm(2) after all autopsies, and it decreased to 2 CFU/100 cm(2) after NTD. In conclusion, the peroxone-based NTD system was effective for decontamination of the air and surfaces in a dissecting room after autopsies of exhumed bodies. Forensic pathologists are at an increased risk of various infections, particularly those associated with hepatotropic viruses, coronaviruses, meningococci, or Mycobacterium tuberculosis [1] [2] [3] [4] [5] . Moreover, autopsies of exhumed bodies pose a particular risk of infections with pathogenic strains of bacteria or fungi from decomposing bodies or environment, which can be life-threatening even in immunocompetent people [5, 6] . For example, Aspergillus flavus, often found in corpses, may cause fatal invasive aspergillosis [6, 7] . A community of bacteria, fungi or other organisms colonizing the cadaver is called necrobiome [8] . Necrobiome may contain Eurotium repens, isolated from the surfaces of skin and bones of corpses [9] and molds such as Penicillium oxalicum and Cladosporium colocasiae, isolated from corpses preserved in low percentages (4%) of formaldehyde [10] . Fungi metabolize organic matter in situ and change both its biochemical and physicochemical properties and microbial community structure [11] . Pathogens may be acquired by inhalation (droplet, air dust, aerosol generated during the opening body), ingestion, direct skin contact or contact with infected surfaces in the dissection room (entry though pre-existing breaks in the skin, and through the mucous membranes of the eyes, nose or mouth) [12] . Thus, it is important to use effective methods of disinfection in forensic pathology facilities. In healthcare, no-touch automated disinfection (NTD) systems are gaining increasing popularity in addition to standard surface disinfection [16] [17] [18] [19] . Typically, NTD systems use substances such as hydrogen peroxide or chlorine dioxide to automatically disinfect whole rooms [20] [21] [22] . Advanced oxidation processes, such as the combination of hydrogen peroxide with ozone (peroxone), are also used [23] . NTD systems are effective against bacteria, viruses, and fungi, including Aspergillus spp., Penicillium spp., and Fusarium spp. [24] . However, available data regarding fungal infection after autopsies of exhumed bodies are limited while the performance of the NTD system after autopsies has not been investigated so far. In this study, we investigated the effectiveness of a peroxone-based NTD system in decontaminating dissecting rooms after autopsies of exhumed bodies. To the best of our knowledge, this is the first study addressing the effectiveness of peroxone-based NTD system in disinfection following autopsies of exhumed bodies. Table 2 shows all the species of bacteria and fungi identified in the study. These organisms were identified after autopsies using VITEK ® 2 automated system. All identified microorganisms belong to environmental bacteria and fungi. After autopsies, the mean bacterial burden in the air was 171 (range 35-263) colony forming units (CFU)/m 3 , and it decreased to 3 (0-23) CFU/m 3 after decontamination ( Figure 1 ). The mean fungal burden in the air was 221 (43-290) CFU/m 3 , and it decreased to 9 (0-43) CFU/m 3 after decontamination ( Figure 1 ). The mean all-surface microbial burden was 79 (44-238) CFU per 100 cm 2 after all autopsies, and it decreased to 2 (0-18) CFU per 100 cm 2 ( Figure 1 ). Table 3 shows detailed contamination data for all surfaces together with respective safety levels. In 8 of 11 autopsies, the use of an NTD system resulted in no detectable microbiological contamination. In the three remaining autopsies, there was residual level 1 (two autopsies) and level 2 (one autopsy) contamination (Table 3) . Table 3 . The microbiological burden on all surfaces before and after no-touch decontamination for all autopsies. Values represent microbiological contamination in CFU/100 cm 2 (risk level) [25] . Dissecting Table The Working Surface of the Dissecting Table Floor The Working Before After autopsies, the mean bacterial burden in the air was 171 (range 35-263) colony forming units (CFU)/m 3 , and it decreased to 3 (0-23) CFU/m 3 after decontamination (Figure 1 ). The mean fungal burden in the air was 221 (43-290) CFU/m 3 , and it decreased to 9 (0-43) CFU/m 3 after decontamination ( Figure 1 ). The mean all-surface microbial burden was 79 (44-238) CFU per 100 cm 2 after all autopsies, and it decreased to 2 (0-18) CFU per 100 cm 2 ( Figure 1 ). Table 3 shows detailed contamination data for all surfaces together with respective safety levels. In 8 of 11 autopsies, the use of an NTD system resulted in no detectable microbiological contamination. In the three remaining autopsies, there was residual level 1 (two autopsies) and level 2 (one autopsy) contamination (Table 3) . Table 3 . The microbiological burden on all surfaces before and after no-touch decontamination for all autopsies. Values represent microbiological contamination in CFU/100 cm 2 (risk level) [25] . This study showed that peroxone-based NTD system was effective in decontaminating the air and surfaces in a dissecting room after autopsies of exhumed bodies. Importantly, the NTD system effectively reduced or eradicated both bacterial and fungal contamination. The literature addressing safety issues in dissection rooms recommend the use of personal protective equipment, such as gloves, goggles or masks during autopsies [2] [3] [4] . Current guidelines regarding decontamination are limited to cleaning and disinfection of surfaces and tools, depending on the potential infectious agent [26] . Recently, a European standard describing methods of disinfection of nonporous surfaces by automated distribution of chemicals was released [27] . This document will allow to apply a uniform standard to assess and compare the effectiveness of available NDT systems. NTD systems are used in so-called clean conditions, i.e., after initial cleaning and disinfection of surfaces. In our study, the level of microbiological contamination was not studied directly after initial cleaning with sodium hypochlorite. However, we found that the microbiological level in the air, where sodium hypochlorite was not used, decreased after the NTD system. The initial cleaning and disinfection followed by using NTD system should be considered as an integrated approach. Decontamination of dissecting rooms is important to reduce the risk of infections, particularly after forensic autopsies of exhumed bodies, which can cause acute life-threatening infectious diseases. In our study, we identified several potentially pathogenic strains of bacteria and fungi after the autopsies (Table 2) ; however, the microbial burden was low. According to the EU regulations, the number of microorganisms in the air should not be greater than 500 CFU/m 3 [25] . In our study, this threshold safety level was not reached after autopsies of exhumed bodies, even before NTD. Nevertheless, the NTD system reduced the number of microorganisms to even lower levels. Our results are in line with a previous study in which another NDS system based on hydrogen peroxide and silver cations was used to decontaminate hospital ventilation systems [28] . In that study, contamination with Aspergillus fumigatus was eradicated after disinfection. In our study, the microbial burden was not detectable after the use of NTD system in 8 of 11 autopsies, and in the remaining autopsies, the residual microbial contamination was low. Fungal contamination is a particular concern after autopsies of exhumed bodies. The growth of fungi is often visible on exhumed bodies, and the spores of different fungi, such as Aspergillus spp. and Penicillium spp. are often present [5, 29] . Fungi are very resistant to low humidity, and fungal conidia are able to survive for several decades even in liquid nitrogen or when lyophilized [30] . Fungi and mycotoxins may cause many diseases. For example, Aspergillus flavus is the etiological factor of sinusitis, keratitis, or skin lesions [31] , and Aspergillus flavus or Aspergillus fumigatus may cause asthma or allergic pneumonitis [32] [33] [34] [35] . Moreover, Aspergillus spp. may lead to life-threatening conditions, such as fatal invasive aspergillosis [6, 7] . In our study, both Aspergillus flavus and Aspergillus fumigatus were identified. This is in line with findings of Schwarz et al., who also reported the presence of Aspergillus fumigatus on decomposed bodies [5] . Similarly to reports by Schwarz et al. [5] and Łukaszuk et al. [6] , most fungi identified in our study were recognized as safe (belonging to risk group 1). Two fungal isolates reported in our study, Cladosporium spp. and Penicillium spp., are common environmental saprophytes. Nevertheless, epidemiological studies have shown an association between exposure to Penicillium and increased risk of wheeze, persistent cough, and higher asthma severity score [36] . Moreover, some species (classified as risk group ≤3) of Cladosporium spp. and Penicillium spp., may pose a risk of severe disease [37, 38] . Some species previously classified as Cladosporium and Penicillium have been re-classified as risk group 3 pathogens, e.g., Cladophialophora bantiana, causing severe infections of central nervous system characterized by high mortality rate [39] , and Talaromyces (Penicillium) marneffei, causing severe deep infections. Despite the fact that these species are mostly common in Thailand, Cambodia, Taiwan, and India, the cases of infections with these pathogens have also been reported in other regions [40] . The presence of Cladosporium spp. and Penicillium spp. on human corpses had been shown previously [41] [42] [43] [44] . In contrast to other studies, we did not detect fungi belonging to Candida species, which are recognized as possibly allergenic [5, 44] . This study has some limitations. Firstly, it was limited to a single dissecting room, and our observations need to be confirmed in other facilities. We used sodium hypochlorite for pre-cleaning and the residual chlorine could affect the microbial load at the time of assessment. The level of microbiological contamination was not studied directly after this procedure. Moreover, we used only one device for NTD, and other systems available on the market would require similar investigations. Nevertheless, because there is limited data on the use of NTD systems in dissecting rooms, our study presents useful information for facilities that conduct autopsies, particularly forensic ones. In conclusion, NTD system seems promising for the decontamination of dissecting rooms after autopsies of exhumed bodies. Standards for the use of NTD systems in dissecting rooms are yet to appear, and until then the instructions delivered by manufacturers of specific devices should be followed. We carried out 11 autopsies of exhumed bodies. Deaths occurred in 2010 as a result of injury; exhumations and autopsies were performed in 2018. We used the NTD system directly after autopsies of exhumed bodies. Before NTD was applied, the dissecting room was washed with sodium hypochlorite, according to the manufacturer's instructions. Sodium hypochlorite is active against bacteria, viruses, spores, fungi, and mycotoxins [26] . The microbiological burden in the air and on various surfaces was measured directly after each autopsy and after decontamination with the Airdecon 200 TM system. We used the Airdecon 200 TM NTD system (Amity International, Barnsley, United Kingdom) in a dissecting room of a volume of 78 m 3 . The system sprays a peroxone vapor (a combination of hydrogen peroxide and ozone) to decontaminate all surfaces. The duration of decontamination was 1 h each time. Decontamination cycle consisted of the following phases: hydrogen peroxide phase, ozone phase followed by peroxone forming, and one-hour contact phase during which peroxone decomposed. For safety reasons, the device detects residual hydrogen peroxide level after the decontamination procedure. We used the MicroBio MB 1 PLUS air sampler (Parrett, Bromley, United Kingdom) to measure the microbiological burden in the air. The MicroBio MB1 air sampler collects airborne micro-organisms on Pathogens 2020, 9, 648 6 of 8 the surface of Petri dishes layered with the malt extract agar and the tryptic soy agar. After exposure, the dishes were removed and incubated under aerobic conditions, and the colony growths were counted. The count and the volume of air sampled were used to calculate the number of CFU per m 3 . In our study, we calculated the mean CFU/m 3 values from three air samples. The device was placed 1.5 m from the floor, all doors and windows were closed, and 300 m 3 of air was sampled thrice according to the PN-EN 13098 standard approved by the Polish Committee for Standardization [45] . We used 25 cm 2 , convex RODAC plates (Replicate Organism Detection and Counting) layered with tryptic soy agar with inactivators of inhibitory substances to measure contamination of surfaces (dissecting table, the working surface of the dissecting table, floor, working surface of tools trolley, sitting surface of chair). The plates were pressed (500 g/cm 2 ) against the surface for 10 s, with no side movements, and were later incubated at 35 • C under aerobic conditions. The growth of microorganisms was measured in CFU per 100 cm 2 , and then expressed as a risk level according to the 1993 Draft European Standard CEN/TC 243/WG2 [46] ; this was as follows: low risk, <10 CFU/100 cm 2 ; moderate risk, 10-100; high risk, >100-1000, very high risk, >1000. The identification of bacteria was carried out with an automatic detection system Vitek ® 2 (Biomerieux, Marcy-l'Étoile, France), according to the manufacturer's instructions. VITEK ® 2 is an automated mass spectrometry microbial identification system that uses Matrix-Assisted Laser Desorption Ionization Time Biosafety considerations for autopsy Issues in the handling of cases of tuberculosis in the mortuary Biosafety Level 3 Laboratory for Autopsies of Patients with Severe Acute Respiratory Syndrome: Principles, Practices, and Prospects Molecular identification of fungi found on decomposed human bodies in forensic autopsy cases Analysis of the incidence fungi in a crypt cemetery Epidemiology of Pulmonary Aspergillosis in Hospitalized Patients in Poland During 2009-2016 Fungal succession during mammalian cadaver decomposition and potential forensic implications Analysis of fungi detected in human cadavers Sommatas, A. Investigation of airborne fungi and their ability to grow on formalin-fixed human cadavers Soil fungal community shift evaluation as a potential cadaver decomposition indicator Health and safety at necropsy Peroxone chemistry: Formation of H 2 O 3 and ring-(HO 2 )(HO 3 ) from O 3 /H 2 O 2 Alternative Disinfectants and Oxidants Guidance Manual Introduction to Photochemical Advanced Oxidation Processes for Water Treatment Environmental decontamination following occupancy of a burns patient with multiple carbapenemase-producing organisms Efficiency of hydrogen peroxide in improving disinfection of ICU rooms Decontamination devices in health care facilities: Practical issues and emerging applications Effect of airborne hydrogen peroxide on spores of Clostridium difficile Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems Decontamination of a Hospital Room Using Gaseous Chlorine Dioxide: Bacillus anthracis, Francisella tularensis, and Yersinia pestis Application of a novel decontamination process using gaseous ozone Advanced oxidation processes-current status and prospects Decontamination of room air and adjoining wall surfaces by nebulizing hydrogen peroxide on the protection of workers from risks related to exposure to biological agents at work Infection control at autopsy: A guide for pathologists and autopsy personnel Polish Committee for Standardization. Chemical Disinfectants and Antiseptics. Methods of Airborne Room Disinfection by Automated Process. Determination of Bactericidal, Mycobactericidal, Sporicidal, Fungicidal, Yeasticidal, Virucidal and Phagocidal Activities Microbiological Air Quality in Heating, Ventilation and Air Conditioning Systems of Surgical and Intensive Care Areas: The Application of a Disinfection Procedure for Dehumidification Devices Sensitization to fungal allergens: Resolved and unresolved issues Aspergillus fumigatus-What Makes the Species a Ubiquitous Human Fungal Pathogen? Aspergillus flavus: Human pathogen, allergen and mycotoxin producer Combined genotyping strategy reveals structural differences Pathogens 2020 between Aspergillus flavus lineages from different habitats impacting human health Occupational exposure to airborne fungi among rice mill workers with special reference to aflatoxin producing A. flavus strains Aflatoxins: Characteristics and impact on human health Mold Sensitization in Asthmatic and Non-asthmatic Subjects Diagnosed with Extract-Based Versus Component-Based Allergens Fungal Exposure and Asthma: IgE and Non-IgE-Mediated Mechanisms Cladosporium Sphaerospermum Causing Brain Abscess, a Saprophyte Turning Pathogen: Case and Review of Published Reports Penicillium Species and Their Associated Mycotoxins Cladophialophora Bantiana: A Rare Intracerebral Fungal Abscess-Case Series and Review of Literature. Surg Talaromycosis (Penicilliosis) Due to Talaromyces (Penicillium) marneffei: Insights into the Clinical Trends of a Major Fungal Disease 60 Years After the Discovery of the Pathogen Determination of the time of death by fungal growth Microbiological analysis of a mummy from the archeological museum in Zagreb Fungi can be a useful forensic tool Fungal microbiota dynamics as a postmortem investigation tool: Focus on Aspergillus, Penicillium and Candida species Polish Committee for Standardization. Workplace Atmosphere-Guidelines for Measurement of Airborne Microorganisms and Endotoxins European Committee for Standardization. CEN/TC 243-Cleanroom Technology Funding: This research received no external funding. The authors declare no conflict of interest.