key: cord-0849527-py2yyxgi authors: Fung, Stephen; Ashmawy, Hany; Krieglstein, Christian; Halama, Thomas; Schilawa, Dustin; Fuckert, Oliver; Hees, Anita; Kröpil, Feride; Rehders, Alexander; Lehwald-Tywuschik, Nadja C.; Knoefel, Wolfram Trudo title: Vertical traction device prevents abdominal wall retraction and facilitates early primary fascial closure of septic and non-septic open abdomen date: 2022-02-11 journal: Langenbecks Arch Surg DOI: 10.1007/s00423-021-02424-1 sha: 69482d5e9717f6c9f30b52a04e19ff4d820d8b24 doc_id: 849527 cord_uid: py2yyxgi PURPOSE: One of the major challenges in the management of patients with septic and non-septic open abdomen (OA) is to control abdominal wall retraction. The aim of this study was to evaluate the impact of a novel vertical traction device (VTD) on primary fascial closure (PFC) and prevention of fascial retraction. METHODS: Twenty patients treated with OA were included in this retrospective multicenter study. All patients were initially stabilized with laparostomy and the abdomen temporarily sealed either with a Bogotá bag or a negative pressure wound therapy system (NPWT). RESULTS: The mean duration of OA and fascia-to-fascia distance (FTF) prior to the VTD application were 3 days and 15 cm, respectively. At relook laparotomy 48 h after VTD implementation, the mean FTF distance significantly decreased to 10 cm (p = 0.0081). In all cases, PFC was achieved after a mean period of 7 days. Twelve patients received the VTD in combination with a NPWT, whereas in eight patients, the device was combined with an alternative temporary abdominal closure system (TAC). Although not statistically significant, the FTF distance remarkably decreased in both groups at relook laparotomy 48 h following the device implementation. The mean periods of PFC for patients with septic and non-septic OA were comparable (7.5 vs. 7 days). During follow-up, two patients developed an incisional hernia. CONCLUSION: Vertical traction device prevents fascial retraction and facilitates early PFC in OA. In combination with NPWT, rapid fascial closure of large abdominal defects can be achieved. Septic peritonitis (SP), abdominal compartment syndrome (ACS), and damage control surgery (DCS) often lead to open abdomen (OA) treatment [1, 2] . In most cases, laparostomy is a life-saving surgical procedure. Patients with Nadja C. Lehwald-Tywuschik and Wolfram Trudo Knoefel equally contributed to the work OA are critically ill and are often susceptible to multiple organ dysfunctions [3] . Particularly when prolonged, OA has been reported to be associated with increased risk of bowel adhesions, entero-atmospheric fistulas, intra-abdominal abscesses, and formation of complex abdominal wall hernias due to loss of domain [4] [5] [6] [7] [8] . According to the World Society of Emergency Surgery (WSES) guidelines, early fascial closure should be the strategy for the management of OA once any requirements for ongoing resuscitation have ceased and the source control has been definitively reached [1] . Thus, early primary fascial closure (PFC) should be a main treatment goal of OA to mitigate morbidity and mortality [9] . However, early PFC of OA still remains a challenge. In the last decade, several techniques for temporary abdominal closure systems (TAC) of OA have been implemented including Bogotá bag, Wittmann Patch®, skin closure only, dynamic fascial traction devices, and negative pressure wound therapy (NPWT) [10] [11] [12] [13] [14] [15] [16] . PFC rates of various TAC techniques are heterogeneous and have been reported with 69-92% [4, 13, 17, 18] . Nowadays, the preferred standard technique for TAC of OA is the NPWT [1] . NPWT is widely reported to be associated with high fascial closure and low complication rates of non-septic OA (e.g., trauma patients) [2, [19] [20] [21] . However, several studies demonstrated that patients with septic OA (e.g., with peritonitis) have lower PFC rates compared with trauma patients [19, 20, 22] . Interestingly, combined with a dynamic closure procedure, NPWT has been observed to achieve higher closure rates compared with NPWT alone [15, 18, [23] [24] [25] . In the literature, the abdominal re-approximation anchor (ABRA) and the vacuum and mesh mediated fascial traction (VACM) have been described as effective dynamic closure procedures [13, 14, 18, 25, 26] . Both techniques exert a dynamic horizontal traction on the fascia, which can be reapproximated at bedside (ABRA) or in repeated abdominal explorations (ABRA/VACM). The vertical traction device (Fasciotens® Abdomen) is a novel device, which exerts a dynamic vertical traction on the fascia. To date, this device has only been reported in preclinical trials to prevent fascial retraction during OA and to reduce the necessary traction force for fascial closure in a porcine model [27] . In a recent case report, the application of the vertical traction device (VTD) was reported for the first time in a single patient to enhance early PFC without mesh implementation or complex abdominal wall reconstruction [28] . However, this study represents the first clinical series with this novel device in patients with open abdomen. The primary aim of this multicenter study was to evaluate the primary fascial closure (PFC) rates following the vertical traction device (VTD) implementation and to determine possible complications related to its clinical application. Secondly, we performed a subgroup analysis to investigate the clinical impact of vertical traction on fascial retraction and to evaluate the rates of primary fascial closure of patients with septic and non-septic open abdomen. Furthermore, the outcomes of vertical traction were investigated when combined with a negative pressure wound therapy or an alternative temporary abdominal closure system. Additionally, the underlying complications related with the device implementation were analyzed. This retrospective multicenter study consisted of 20 patients treated between January 2019 and May 2020 with open abdomen (OA) at six different hospitals in Germany. The local ethic committee approved this study (study no: 2021-1319). In each center, the same surgeon performed the device application, supervised the device during clinical use, and performed the postoperative follow-up at the outpatient clinic. Causes of septic OA were gastrointestinal perforation (n = 10) and necrotizing, infected pancreatitis (n = 2). Non-septic OA resulted of ACS after aortic rupture and repair (n = 4), intestinal ischemia (n = 2), and mechanical ileus (n = 2). In all cases, the VTD was applied after hemodynamic control of the patient's clinical condition. In most cases, a moderate catecholamine dose (norepinephrine) was applied to achieve hemodynamic stability. Eighteen patients were treated at the intensive care unit (ICU) and were under mechanical ventilation until the device was dismounted prior to primary fascial closure. Two patients were treated at the intermediate care unit (IMC) and were under a patient-controlled analgesia (PCA) prior to device application. In twelve cases, the vertical traction device (VTD) was combined with a negative pressure wound therapy system (VTD-NPWT group) and in eight cases with an alternative temporary abdominal closure system (e.g., Bogotá bag) (VTD-TAC group). Patient demographic data were retrieved from medical records. Björck classification [29] , fascia-tofascia distance (FTF), APACHE II score, duration of OA, cause of OA, number of relook procedures until fascial closure, complications related to device application, and occurrence of incisional hernia during outpatient clinic followup were collected from documented data of the supervising surgeons. The vertical traction device (Fasciotens® Abdomen; Essen, Germany) description was derived from the study of Eickhoff et al. [27] . The main principle of the device is the application of dynamic vertical traction along both fascial margins over a clamping system (Figs. 1 and 2 E and F). The device consists of a beam with two buttresses positioned on the thorax and anterior pelvic ring. After midline or transverse laparotomy, a doubled vicryl mesh is sewed to each fascial margin using commercial sutures. Six sutures on the mesh of each fascial margin carried through eyelets are fastened on a common suspension. The eyelet suspension is attached to a longitudinal beam with a heightadjustable connection. Using this dynamic connection, the fascial traction can be increased or decreased as needed. The applied traction force is adjustable along a range of 0-100 N (Newton) as presented on the varying colored fields of the longitudinal beam. In our cases, we adjusted the fascial traction to the dark green field of the longitudinal beam. This field corresponds to a traction force of 60-80 N according to the manufacturer's specifications. Once suspended and tensed on the adjustable longitudinal beam, the fascial margins are pulled vertically relative to the thorax and pelvis. This vertical traction withstands the natural muscle traction, counteracts resulting fascial retraction, and enhances anterior extensive tissue development. Simultaneously, the open abdomen allows pressure release. The treatment periods were approximately 5 h, followed by 1 h of treatment break. Over a period of 24 h, the dynamic traction force was applied for about 20 h. For the alert patient at the IMC unit, treatment breaks were undertaken according to the patient's needs (< 20 h/24 h). As recommended by the manufacturers, this device was only used in patients under mechanical ventilation treated at the intensive care unit (ICU) and in patients at the intermediate care unit (IMC) with appropriate patient-controlled analgesia (PCA). Prior to device application, the patient was intraoperatively fully relaxed with a muscle relaxant agent (e.g., Esmeron®), before the fascia-to-fascia (FTF) distance was measured ( Fig. 2A ). After abdominal lavage and surgical debridement of the fascia to create clean mobile fascial margins, a doubled vicryl mesh (maximum width 2-3 cm) was sewed on both fascial margins. Hereafter, twelve commercial surgical threads, with six sutured on each side to defined areas of both meshes (Fig. 2 C and D), were directly vertically or cross-tensed on the vertical traction device (VTD) clamping system. The abdominal cavity was sealed either with a Bogotá bag and abdominal dressings ( Fig. 2 B and E) or a negative pressure wound therapy (NPWT) system ( Fig. 2 D and F). During repeated abdominal exploration 48 h after VTD implementation and during further re-exploration, the FTF distance was determined at full patient relaxation. To preserve fascial integrity, the doubled meshes sewed at both fascial edges were left in place as long as possible and only replaced when defects occurred, which impaired traction force. According to Eickhoff et al. [27] , a significant reduction of the initial FTF distance was observed between 24 and 48 h after application of the device in a porcine model. For comparability, we used the values of FTF distance at The statistical analysis was performed with SPSS 25.0 (Statistical Package for Social Sciences; SPSS Inc., Chicago, IL, USA). All data are presented as mean value, range, and percentages. Mean values of continuous variables between groups were compared with Student's t-test. Statistical significance was considered at p < 0.05. Patient characteristics are summarized in Table 1 . Twenty patients treated with OA were included in this study. Our patient collective consisted of sixteen males and four females with a mean age of 60 years (range 36-80 years) ( Table 1 ). The mean APACHE II score was 20 (range [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [28] . According to the OA classification of Björck [29] , twelve patients were classified as grade 2B, and four patients each were graded 1A and 1B, respectively. Thus, as proposed by Björck [29] , patients with grade 2B were classified as septic OA (n = 12), whereas those graded Björck 1A and 1B were considered non-septic OA (n = 8). For the total cohort, the mean period prior the vertical traction device (VTD) application was 3 days (range 0-14 days) ( Table 2 ). The fascia-to-fascia (FTF) distance before VTD application was 15 cm (range 8-23 cm). However, at relook laparotomy 48 h after the device was implemented, the mean FTF distance significantly decreased to 10 cm (range 6-17 cm; p = 0.0081) ( Table 4 ). In all cases (n = 20), definitive skin and PFC was achieved without the use of mesh or component separation with a mean period of 7 days (range 3-24 days). However, four patients (20%) developed a subcutaneous wound dehiscence 1 week after primary closure. In these cases, the fascia and muscle were not affected. After debridement of the subcutaneous tissue, negative pressure wound therapy (NPWT) was applied for 1 week until secondary skin closure was performed. Two patients developed a fascial dehiscence and were treated [30] . Further investigated parameters such as respiratory impairments and intra-abdominal hypertension (IAH) related to the device application were not observed. Moreover, no patient died during clinical course. One patient died related to a COVID-19 infection 4 months after discharge from hospital. The mean number of relook procedures until fascial closure in our patient cohort was four (range 1-7). In twelve patients, the vertical traction device (VTD) was applied in combination with a negative pressure wound therapy system (NPWT) (VTD-NPWT group), while in eight patients, the VTD was implemented with an alternative temporary abdominal closure system (TAC: Bogotá bag with abdominal dressings) (VTD-TAC group) ( Table 3) . The mean open abdomen (OA) duration and fascia-tofascia (FTF) distance before VTD-NPWT application was 2 days (range 0-6 days) and 17.5 cm (range 13-23 cm), respectively, whereas mean duration of OA was 4.5 days (range 1-14 days) and the FTF distance 13 cm (range 8-15 cm) before VTD-TAC implementation (Tables 3). In both groups, a distinct reduction of FTF distance was evident at relook laparotomy 48 h after VTD application: 14 cm (range 7-14 cm) for the VTD-NPWT group and 9.5 cm (range 6-10 cm) for the VTD-TAC group (Table 4) , respectively. The mean days to primary fascial closure (PFC) for patients in the VTD-NPWT group (7 days, range 3-24 days) were comparable to those with VTD-TAC (7.5 days; range 5-14 days). The mean duration of OA in both groups before and after implementation of the device was 10.5 days (range 5-30 days) for the VTD-NPWT group and 11.5 days (range 7-28 days) for the VTD-TAC group. Interestingly, although the fascia-to-fascia distance of patients with non-septic OA (17.5 cm; range 15-20 cm) prior to VTD application was larger than that of patients with septic OA (13.5 cm; range 8-23 cm), both groups achieved similar primary fascial closure (PFC) period after device insertion (non-septic OA vs. septic OA: 7 days; range 6-12 days vs. 7.5 days; range 3-24 days; p = 0.8970) ( Table 5 ). However, the mean duration of OA in patients with septic OA prior to VTD application was longer (4.5 days; range 1-14 days) than in patients with non-septic OA (1.5 days; range: 0-5 days). Data of this subgroup are summarized in Table 5 . In this study, a novel device that exerts a dynamic vertical traction force on the fascia was successfully implemented in a series of 20 patients. A major advantage of vertical traction that we observed was the ability to early prevent fascial retraction, especially in cases with increased intra-abdominal volume due to visceral edema. In our patient cohort, early PFC was achieved in all cases (100%) without mesh augmentation or component separation. No severe complications related to the novel device application were observed. Early primary fascial closure is crucial to prevent the well-known complications of open abdomen (OA). Combinations of temporary abdominal closure systems with dynamic closure procedures have recently been reported to illustrate the best primary fascial closure (PFC) rates [2, 15, 18, 31, 32] . However, early application of dynamic closure procedures are restricted by various factors such as hemodynamic instability, uncontrolled source of infection, persistent abdominal peritonitis, or increased intra-abdominal volume due to visceral edema [13, 27] . Verdam et al. [13] and Reimer et al. [26] have previously reported an average duration of OA of 12 days and 18 days, respectively, prior to application of the abdominal re-approximation anchor system (ABRA). Reimer et al. reported a delayed Verdam emphasized that timing to approximation could be an important factor for successful closure. In contrast to the above-mentioned studies, the mean duration of OA prior to the vertical traction device (VTD) implementation in our mixed patient cohort (12 septic OA and 8 non-septic OA) was 3 days (range 0-14 days), which was shorter compared to the two other studies. At this timing to approximation, we observed a successful closure rate of 100%. Two patients received the device directly at initial laparotomy due to an abdominal compartment syndrome (ACS) caused by a mechanical ileus. In all cases, early vertical dynamic traction exerted on the fascia by the device was possible Additionally, despite bowel distension and visceral edema, dynamic traction was feasible without causing iatrogenic intra-abdominal hypertension. Only one patient received the device after 14 days of OA treatment due to infected, necrotizing pancreatitis. Our high closure rates highlight the fact that timing to dynamic approximation plays an important role for successful primary fascial closure. In earlier studies, success rate of primary fascial closure has been reported to depend on the etiology of the open abdomen [2, 19, 20, 22] . In the systematic review and evidence-based recommendation for the use of negative pressure wound therapy (NPWT) by Brunhin et al. [2] , patients with septic OA displayed lower fascial closure rates at the end of the therapy compared to patients with non-septic OA. Interestingly, when combined with a dynamic closure device, NPWT showed increased primary fascial closure rates. Verdam et al. [13] reported a delayed PFC rate of 88% for 14 patients with advanced septic OA (Björck grade 2B-4) after a mean OA duration of 25 days (range 7-48 days) using the dynamic traction of ABRA (abdominal re-approximation anchor system). Mintziras et al. [33] reported a delayed PFC rate of 47% for patients with secondary peritonitis under NPWT. In this study of Mintziras et al., the duration of OA until fascial closure was not analyzed. In a previous study by Tolonen et al. [17] , a delayed PFC rate of 80% was reported over a median OA duration of 7 days in patients with secondary peritonitis treated with NPWT and a dynamic closure procedure (mesh-mediated fascial traction). Recently, Granger et al. [16] described a myofascial closure rate of 86.5% in patients with peritonitis treated mainly (97.7% of the cases) with ABThera™ dressing (NPWT with protective visceral layer). In this study, an average OA duration of 2.1 days was reported. These findings were in-line to our study in which twelve patients with septic OA (Björck grade 2B) were treated using the dynamic vertical traction device (VTD). Our primary PFC rate was 100% after a mean OA duration of 11.5 days (range 5-28 days). Although our OA duration was longer compared to previous studies [13, 17] , we experienced higher closure rates as reported in the literature. Similarly, for patients with non-septic open abdomen, total OA duration and primary fascial closure rates are heterogeneously reported. PFC rates vary from 65 to 100% and OA duration from 2.1 to 12.5 days [15, 16, 18, 21, 32] . In our cohort of eight patients with non-septic OA, PFC rate was 100% with a mean OA duration of 10.5 days (range 6-13 days). These results are better or in-line with recent reported studies cited above. As previously mentioned, a temporary abdominal closure system in combination with a dynamic traction procedure has been reported to have best primary closure rates and enhance rapid fascial closure in both septic and non-septic open abdomen. In our case series, twelve patients were treated with a combination of the vertical traction device (VTD) and a negative pressure wound therapy (NPWT) (VTD-NPWT group), and eight patients received VTD in combination with an alternative temporary abdominal closure system (Bogotá bag and abdominal dressings) (VTD-TAC group). Prior to device application, the mean fascia-tofascia (FTF) distance of patients in the VTD-NPWT group was significantly larger than the VTD-TAC group (17.5 cm vs. 13 cm, p = 0.0532). Interestingly, there was no significant difference between the duration of OA after the device was applied in both groups (VTD-NPWT vs. VTD-TAC: 7.5 days vs. 7 days; p = 0.8970). This result demonstrates the beneficial effect of NPWT in combination with a dynamic vertical traction device on treating large fascial defects. One of our main objectives during clinical use of this device was to investigate whether the weight exerted by the device on the thorax and pelvis affected the patient's hemodynamic and respiratory conditions, and whether pressure sores occurred. Additionally, we investigated whether intraabdominal hypertension could occur when implementing this device. Therefore, these parameters were continuously monitored until the device was dismantled. One patient developed a grade one pressure sores according to Barczak et al. [30] at the position of the buttress on the anterior pelvic ring. The pressure sores were treated conservatively. Four patients developed a subcutaneous wound dehiscence 1 week after primary fascial closure (PFC), and two patients developed a fascial dehiscence leading to an incisional hernia 6 months after discharge. Our results revealed due to the high rate of PFC and the low rate of device-related complications that this device appears to be an effective tool in the treatment of OA. This study has some major limitations due to its retrospective nature and the low number of patients. However, this is the first study to assess the clinical use of this novel device in a series of patients. This technique need to be validated in prospective controlled trial with a larger number of patients. Additionally, future studies should evaluate which patients might benefit from early vertical traction. Dynamic vertical traction prevented fascial retraction, enhanced abdominal wall extension, and thus facilitated early PFC in septic and non-septic open abdomen. In combination with negative pressure wound therapy (NPWT), vertical traction promoted rapid fascial closure of large abdominal defects. This could reduce the necessity of complex abdominal wall reconstruction as well as rate of mesh grafting and also mitigate morbidity and the socio-economic burden related to open abdomen treatment. The open abdomen in trauma and non-trauma patients: WSES guidelines Systematic review and evidence based recommendations for the use of negative pressure wound therapy in the open abdomen Both primary and secondary abdominal compartment syndrome can be predicted early and are harbingers of multiple organ failure Is the evolving management of intra-abdominal hypertension and abdominal compartment syndrome improving survival? Complications after 344 damage-control open celiotomies Continuous retention suture for the management of open abdomen: a high rate of delayed fascial closure Prospective evaluation of vacuum-assisted closure in abdominal compartment syndrome and severe abdominal sepsis Temporary abdominal closure techniques Impact of closure at the first take back: complication burden and potential overutilization of damage control laparotomy Techniques for abdominal wall closure after damage control laparotomy: from temporary abdominal closure to early/delayed fascial closure-a review Nonoperative progressive "Bogota bag" closure after abdominal decompression The use of the Wittmann Patch facilitates a high rate of fascial closure in severely injured trauma patients and critically ill emergency surgery patients Delayed primary closure of the septic open abdomen with a dynamic closure system The abdominal reapproximation anchor device Management of open abdomen after trauma laparotomy: a comparative analysis of dynamic fascial traction and negative pressure wound therapy systems An open and closed case: timing of closure following laparostomy Open abdomen with vacuum-assisted wound closure and mesh-mediated fascial traction in patients with complicated diffuse secondary peritonitis: a single-center 8-year experience Open abdomen therapy with vacuum and mesh mediated fascial traction after aortic repair: an international multicentre study The open abdomen and temporary abdominal closure systems-historical evolution and systematic review Open abdomen after trauma and abdominal sepsis: a strategy for management Negative pressure wound therapy management of the "open abdomen" following trauma: a prospective study and systematic review The open peritoneal cavity: etiology correlates with the likelihood of fascial closure The role of the open abdomen procedure in managing severe abdominal sepsis: WSES position paper Vacuum and mesh-mediated fascial traction for primary closure of the open abdomen in critically ill surgical patients Vacuum-assisted wound closure and mesh-mediated fascial traction-a novel technique for late closure of the open abdomen Management of open abdominal wounds with a dynamic fascial closure system A new device to prevent fascial retraction in the open abdomenproof of concept in vivo Prevention of fascial retraction in the open abdomen with a novel device Classification-important step to improve management of patients with an open abdomen Fourth national pressure ulcer prevalence survey Management of the open abdomen using combination therapy with ABRA and ABThera systems Management of the open abdomen using vacuumassisted wound closure and mesh-mediated fascial traction. Langenbecks High risk of fistula formation in vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis-a retrospective analysis Authors' contributions Study conception and design, acquisition of data, drafting of manuscript, and critical revision of the manuscript (S.F., H.A., Ch. K., T.H., D.S., O.F, A.H., N.L., F.K., A.R., W.T.K.) and analysis and interpretation of data (S.F., H.A., A.R., W.T.K.)Funding Open Access funding enabled and organized by Projekt DEAL.Availability of data and material The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.Code availability Not applicable. Ethics approval This study was approved by the local institutional review board (Heinrich Heine University, Duesseldorf, Germany; study no.: 2021-1319). All procedures performed in this study were in accordance with the ethical standards in the 1964 Declaration of Helsinki and its later amendments.Consent to participate Informed consent to participate was waived because no data regarding the cases were disclosed. Informed consent for publication was waived because no data regarding the cases were disclosed. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.