key: cord-0849308-6nu1dikg authors: Zhou, Yu; Shen Ji title: Experimental and numerical study on the transport of droplet aerosols generated by occupants in a fever clinic date: 2020-10-29 journal: Build Environ DOI: 10.1016/j.buildenv.2020.107402 sha: 6ff2f19ed868a36de48ea62a6369c87a9561e270 doc_id: 849308 cord_uid: 6nu1dikg The outbreak of the corona virus disease 2019 (COVID-19) infection has spread to a large number of countries worldwide. The early diagnosis of COVID-19 is complicated by its strong transmission characteristics and no obvious symptoms in the incubation period. Due to the relatively sealed indoor environment and the existing ventilation system, the patients and doctors in the fever clinics of the major hospitals are faced with a huge risk of infection. This study aims to investigate the transport of droplet aerosols generated by both doctors and patients to seek measures to reduce the risk of infection. Taking a typical fever clinic as an object of study, two links in the actual diagnosis and treatment process are selected in this manuscript for investigation by experimental and numerical methods. The effects of different cases of coughing and talking, as well as different contact distances, on the inhalation rate of human droplet aerosols are studied. The purification capacity of the ventilation is evaluated by the analysis results of the particle diffusion track and regional concentration of the entire indoor area and breathing zones. The results show that purification of the same number of droplet aerosols and purification by ventilation work better for coughing than for talking. The best ventilation performance appeared for the case of a patient sitting and coughing (PSC), while the case of a patient lying and talking (PLT) was the worst. Corresponding measures are suggested to improve the air purification effect and reduce the risk of cross infection. 28 infectious diseases is related to the distribution of air flow indoors [2] [3] [4] [5] [6] . The droplets, 1 which are produced by patients with infectious diseases with diameters less than 10 2 µm, are emitted through respiratory exhalation processes [7] [8] , such as breathing [9], 3 coughing [10] and sneezing [11] . Droplets carrying pathogens are spread indoors 4 under the influence of airflow and self-diffusion, causing others who remain indoors 5 to be easily infected by inhaling airborne particles [12] . Therefore, early diagnosis and 6 treatment are important to control the spread of disease. Although the major medical to the level of using a superclean laminar ventilation operating room. The air 23 temperature, air velocity and volumetric flow rate entering and leaving the room were 24 chosen by Alhamid [17] to observe the pressure distribution in the hospital operating 25 room. 26 However, the clinical room is researched less often than other hospital rooms, as 27 mentioned above. Fever clinics have the characteristics of high mobility and high risk 28 of cross infection, especially for the health of indoor occupants during an outbreak. 29 and therefore, all the conclusions in this manuscript will be relevant to other similar 1 fever clinics. Considering the many models provided by FLUENT 16.0 for turbulence 5 calculations, the RNG k-ε turbulence model was theoretically superior to the standard 6 k-ε model for this application [18] . An additional production term reflecting the 7 average strain of the main vortex was added to the ε equation, and the turbulence 8 viscosity was modified, which improved the simulation accuracy of the vortex. Chan 9 et al. [19] pointed out that the RNG k-ε model performs slightly better in predicting 10 the strength of the main vortex compared with the turbulence model of the standard 11 k-ε model, realizable k-ε model, Reynolds stress model (RSM) and large eddy 12 simulation (LES). And the RNG k-ε model with enhanced wall treatment, was used 13 due to its simplicity, robustness and accuracy in predicting airflow fields over solid 14 bodies [20] . Therefore, it is more practical to use the RNG k-ε turbulence models to 15 calculate the air field flow in our study. The series of governing equations are given as 16 follows: 17 The mass equation is: The momentum equation is: The energy equation is: The definitions of the above parameters are listed in Tab. 1. For indoor air, which is regarded as a continuum, while particles are regarded as 2 discrete media, the Lagrangian method is used to track the propagation trajectory. By 3 equating the particle inertia with external forces, the motion equation of the particle 4 for the x-direction in Cartesian coordinates can be obtained as: where u a and u p are the velocity of the air and particle, respectively. ρ a and ρ p are 7 the densities of the air and particle, respectively. g x is the acceleration of gravity in the 8 x-direction. Considering that the particles are subject to the Saffman lifting force and 9 thermophoresis force, F x stands for an additional forces per unit mass [21] . F D (u a -u p ) 10 is the drag force per unit particle mass, and for submicron size particles (diameter 11 =1-10 μm), F D is set to: where µ is the air dynamic viscosity and d p is the diameter of the particle. 14 Considering the velocity slip of the wall in the mechanics of rarefied gas, C c , the 15 Cunningham correction coefficient of the Stokes drag formula can be expressed as: where λ is the mean free-path of gaseous molecules. The turbulent diffusion of particles is simulated by a random orbit model, by which isotropic and to follow a Gaussian distribution, which can be obtained from Eq. (8). where k is the turbulent kinetic energy and ζ is a random variable subject to a 6 normal distribution. The integral time scale T', the time that a particle is in turbulent 7 motion along its trajectory, can be calculated by the turbulent diffusion of particles. The formula is where c is the mass transfer coefficient, which is estimated by the correlation at the To ensure the accuracy of the simulation results, ICEM software is used to 6 discretize the geometry of the model. The tetrahedron unstructured mesh is adopted to For the MV applied in the fever clinic, recirculation is mainly located in the two 8 wall corners of the room. It can be predicted that the position and intensity of the 9 reflux area will have a substantial impact on the diffusion of particles. Considering the 10 obstruction of the instruments and equipment to air flow, the original air distribution 11 changes greatly, and the diffusion path of droplet aerosols will be more complex. To better investigate the particle diffusion track and regional concentration, an respectively. Fig. 4 shows the size distribution of the droplet aerosols emitted from the 6 mouth of the manikin. TSI 8220, ranging the particle diameter from 0.3 to 10 μm, is Fig. 9(a) shows that 13 the droplet aerosols concentration at the outlet reaching the maximum is delayed from 14 J o u r n a l P r e -p r o o f 98 s to 139 s as the distance gradually increases. The peak value is reduced from 1 6.5E -2 µg/m 2 to 4.6E -2 µg/m 2 , the variation law of which is similar to that shown in 2 Fig. 9(c) . The droplet aerosols concentration of the outlet at the three different 3 distances of PSC reaches a stable level of approximately 1E -2 µg/m 2 in the following 4 time. The droplet aerosols concentration of PLC did not remain stable, however, it 5 increased slowly from 2E -2 µg/m 2 after 200 s, which is twice as high as that of PSC in 6 the same period. 7 In Fig. 9(b) , the time when the droplet aerosols appear at the outlet of the fever the PLT in Fig. 9(d) . Fig. 10(a) . In all cases, the droplet aerosols Kang et al. [37] . When the distance is between 1.1 m and 1.3 m, the droplet aerosol 1 concentrations in the PS position are all lower than the maximum concentration 2 (3.52×10 3 pcs/m 3 ) required by ISO6. The optimum value of the droplet aerosols 3 concentration is determined by the case of PSC-1.3, which is lower than the standard 4 of ISO5, 3.52×10 4 pcs/m 3 . This is caused by the layout of indoor facilities where the 5 bed is placed in the corner of the fever clinic. As a result of poor air circulation, 6 droplet aerosols cannot be effectively discharged. Therefore, the purification effect of 7 MV for PS is better than that for PL in the entire indoor area. The patial relationship 8 between the ventilation system and the occupants greatly affects the transport of Overall, the percentage of droplet aerosols inhaled by doctors is smaller than that 10 inhaled by patients, and the risk of infection by doctors is lower in Fig. 12 . Considering the low inhalation percentage of patients and doctors, the ventilation 12 performance for the condition PSC is the best. The highest percentage of droplet 13 aerosols inhaled by the patient is presented in the case of PLT, which is the worst The transport of droplet aerosols is investigated in a typical fever clinic by numerical and experimental method. Twelve different cases are studied to analyses particle diffusion track and regional concentration. The purification effect of PL (patient lying) is worse than PS (patient sitting) in the entire indoor area by the ventilation system. And in the breathing zone, the best performance of the ventilation system is presented in PSC (patient sitting and coughing) while PLT (patient lying and talking) is the worst. For the same number of droplet aerosols, the purification by ventilation works better for coughing than for talking. What to do next to control the 2019-nCoV epidemic The Lancet Acute Respiratory Syndrome Virus Role of ventilation in airborne transmission of 22 Engineerings Recent Progress in Biomaterials, Drugs Development, & Medical 1 Devices: International Symposium of Biomedical Engineering Ansys Fluent 16.0, Theory Guide Validation of a two-dimensional pollutant 5 dispersion model in an isolated street canyon Particles dispersion due to human 8 prostration cycle and ventilation system in a prayer room Dispersion and Deposition of Spherical Particles 11 from Point Sources in a Turbulent Channel Flow Evaporation from drops. Chemical Engineering 14 Progress Simplified modeling of displacement ventilation systems 16 with chilled ceilings Contamination distribution in displacement ventilation-influence of 19 disturbances Heating energy consumption of impinging jet 22 human respiratory tract during expiratory activities Turbulent dispersion of particles using eddy interaction 4 models A study of the dispersion of expiratory aerosols in 7 unidirectional downward and ceiling-return type airflows using a multiphase 8 approach Quantity and Size Distribution of 11 After Characterization of expiration air 15 jets and droplet size distributions immediately at the mouth opening Distribution of droplet aerosols generated by 18 mouth coughing and nose breathing in an air-conditioned room CFD study of 21 exhaled droplet transmission between occupants under different ventilation 22 strategies in a typical office room Ministry of industry and information technology of the people's Republic of 25 Code for design of clean workshop Droplets in the Air-Conditioning Room Vetilation and Air Conditioning and The 3 rd international Conference on Study on transport characteristics of saliva droplets 33 produced by coughing in a calm indoor environment