key: cord-0848745-szem47gq authors: Kim, S.; Wolfe, M. K.; Criddle, C.; Duong, D.; Chan-Herur, V.; White, B.; Boehm, A. title: Effect of SARS-CoV-2 digital droplet RT-PCR assay sensitivity on COVID-19 wastewater based epidemiology date: 2022-04-18 journal: nan DOI: 10.1101/2022.04.17.22273949 sha: da2fff2277b7ffe5e91971dfa3adafcc1b32ab76 doc_id: 848745 cord_uid: szem47gq We developed and implemented a framework for examining how molecular assay sensitivity for a viral RNA genome target affects its utility for wastewater-based epidemiology. We applied this framework to digital droplet RT-PCR measurements of SARS-CoV-2 and Pepper Mild Mottle Virus genes made using 10 replicate wells, and determined how using fewer wells affected assay sensitivity and its performance for wastewater-based epidemiology applications. We used a computational, downsampling approach. When percent of positive droplets was between 0.024% and 0.5% (as was the case for SARS-CoV-2 genes during the Delta surge), measurements obtained with 3 or more wells were similar to those obtained using 10. When percent of positive droplets was less than 0.024%, then 6 or more wells were needed to obtain similar results as those obtained using 10 wells. When COVID-19 incidence is low, as it was before the Delta surge and SARS-CoV-2 gene concentrations are <104 cp/g, using 6 wells will yield a detectable concentration 90% of the time. Overall, results support an adaptive approach where assay sensitivity is increased by running 6 or more wells during periods of low SARS-CoV-2 gene concentrations, and 3 or more wells during periods of high SARS-CoV-2 gene concentrations. assay sensitivity and its performance for wastewater-based epidemiology applications. We used 23 a computational, downsampling approach. When percent of positive droplets was between 24 0.024% and 0.5% (as was the case for SARS-CoV-2 genes during the Delta surge), 25 measurements obtained with 3 or more wells were similar to those obtained using 10. When 26 percent of positive droplets was less than 0.024%, then 6 or more wells were needed to obtain 27 similar results as those obtained using 10 wells. When COVID-19 incidence is low, as it was 28 before the Delta surge and SARS-CoV-2 gene concentrations are <10 4 cp/g, using 6 wells will 29 yield a detectable concentration 90% of the time. Overall, results support an adaptive approach 30 where assay sensitivity is increased by running 6 or more wells during periods of low SARS-31 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 18, 2022. Wastewater-based epidemiology for severe acute respiratory syndrome coronavirus 2 (SARS-47 CoV-2) is becoming an increasingly important tool in monitoring coronavirus disease 2019 48 (COVID-19) incidence rates in communities. Monitoring programs that use samples from 49 publicly owned treatment works (POTWs) 1,2 and from sewer conveyances 3 have actively been 50 implemented to supplement clinical testing data. Wastewater surveillance has the advantage of 51 providing insights into population health by overcoming limitations of clinical testing, such as test 52 seeking behavior and test availability. Wastewater surveillance has also been used to gain 53 insight into the epidemiology of other respiratory viruses such as influenza A virus 4 and 54 respiratory syncytial virus 5 (RSV), as well as gastrointestinal pathogens such as hepatitis A 6 and 55 Salmonella 7 . Therefore, wastewater surveillance is likely to become increasingly useful for 56 assessing various aspects of community health beyond COVID-19. 57 58 SARS-CoV-2 RNA concentrations in wastewater, whether measured in the solid or liquid phase 59 or using quantitative or digital reverse-transcription polymerase chain reaction (RT-PCR), 60 correlate to COVID-19 laboratory incidence rates in the population contributing to the 61 wastewater 8-10 . The lower detection limit, or the sensitivity, of any method for detection of 62 SARS-CoV-2 RNA, or any other disease target, will dictate the lowest levels of disease 63 occurrence that can be detected using wastewater. 64 65 Digital (RT-)PCR can be a sensitive method for detecting disease targets in wastewater. Digital 66 (RT-)PCR methods divide the entire (RT-)PCR solution (master mix, primers, probes and 67 template) into a large number of partitions (droplets or physical partitions in a plate) such that 68 each partition likely contains only one copy of template nucleic acid. By increasing the number 69 of partitions (assuming their volume remains constant) and the associated reaction volume, the 70 analytical sensitivity of the measurement can be increased. For digital droplet RT-PCR (ddRT-71 PCR), the number of partitions can be increased by increasing the number of wells used to 72 analyze samples; the results from droplets generated by all replicate wells are merged to 73 compute the final measurement. An analogous approach can be applied to other methods of 74 digital partitioning. However, increasing the number of partitions used for each sample to 75 improve sensitivity increases project reagent costs. In a previous study, we compared the 76 lowest measurable concentration of SARS-CoV-2 RNA reported by different laboratories using 77 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint different pre-analytical methods and ddRT-PCR, and the detection limit decreased as the 78 number of replicate wells used in the method increased 11 . Authors have reported using between 79 one to ten merged wells without full justification on how the number of wells merged was 80 CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint concentration, respectively, derived from the measurement obtained using 10 wells. The 154 standard deviation of that measurement is the 68% confidence interval as defined by the total 155 error from the instrument software which includes Poisson error and variation among wells; the 156 total error formula is proprietary and not available from the vendor. 157 158 Nonparametric Kendall's tau was used to assess the association between the N gene 159 concentrations in wastewater and laboratory confirmed COVID-19 incidence rates. Kendall's tau 160 was calculated for both the entire time series and the low incidence month of June. For this 161 analysis, zero was substituted for measurements considered NDs. 162 163 The theoretical lower measurement limit was calculated for each number of merged wells (X = 1 164 -10) by: 1) calculating the concentration resulting from three positive droplets total across 165 merged wells out of 20 000 total accepted droplets (average number of droplets generated) per 166 each well merged, and 2) converting the concentration to units of cp/g dry weight using average 167 solid content for samples from each POTW (Table S2) . 168 169 Linear regression was used to derive an empirical relationship between log10-transformed 170 COVID-19 laboratory-confirmed incidence rates and log10-transformed measured SARS-CoV-2 171 N gene concentrations using data obtained by merging ten wells; relationships were quantified 172 for each POTW separately, and for the POTWs in aggregate. For the linear regression, NDs 173 were substituted with half the theoretical lower measurement limit calculated for X = 10. Using 174 the empirical relationship between incidence rate and SARS-CoV-2 RNA concentration for the 175 associated POTW, the lowest detectable COVID-19 incidence rate was estimated based on the 176 calculated theoretical lower measurement limits. 177 178 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint A logistic regression was used to model the fraction of samples that were assigned a 179 concentration (versus assigned ND) for X = 1 -9 as a function of the true concentration of the 180 sample, defined as the concentration obtained using 10 wells. The concentration corresponding 181 to a detection frequency of 0.5 (C0.5) was calculated using the regression equation. For this 182 analysis, half of the theoretical lower measurement limit was substituted for the 6 NDs for X 183 these two regimes (fraction of positive droplets between 0.0015% and 0.5%), then the IQR 221 increases as X decreases and is often greater than the standard deviation from the X = 10 well 222 measurement, particularly when X < 3. Below SARS-CoV-2 concentration of 10 4 cp/g (where 223 the fraction of positive droplets is 0.0062% -0.024% depending on POTW), the value of X 224 below which the relative dispersion, defined by IQR divided by the median, is larger than the 225 standard deviation normalized by the measured concentration for X = 10 scales inversely with 226 SARS-CoV-2 N gene concentration ( Figure S2 An empirical relationship between the log10-transformed COVID-19 incidence rate and the log10-235 transformed SARS-CoV-2 concentration using ten merged wells was derived with linear 236 regression. The regression showed that for 1 log10 increase in SARS-CoV-2 RNA cp/g, there 237 was between 0.50 and 0.88 log10 increase in laboratory-confirmed COVID-19 incidence rate 238 (Table S3) , depending on the POTW. The data from all four POTWs appear to fall on a single 239 line when COVID-19 incidence rate is plotted against SARS-CoV-2 concentration ( Figure S3) ; 240 when data from all POTW are combined, there was a 0.64 log10 increase in laboratory-241 confirmed COVID-19 incidence rate for 1 log10 increase in SARS-CoV-2 RNA cp/g. 242 Theoretical lower measurement limit (Table S4 ) and the corresponding incidence rate lower limit 244 (Table S5 ) was calculated. The theoretical lower measurement limit for each POTW ranged 245 from 7500 (SJ) to 24000 (Gil) cp/g when using only one well and from 750 (SJ) to 2400 (Gil) 246 cp/g when using ten merged wells. Since this theoretical lower measurement limit was 247 calculated with average solid content of samples from each POTW by measuring the percent 248 weight of the dewatered solids and assuming a total of 20 000 generated droplets, the observed 249 lower measurement limit may be different. The corresponding incidence rate lower limit per 100 250 000, calculated using the empirical relationships in Table S3 , ranged from 1.6 (SJ) to 6.9 (Gil) 251 when using one well and from 0.2 (SJ) to 1.4 (Gil) when using ten merged wells (Table S5) . with 7-day smoothed COVID-19 incidence rates at all four POTWs regardless of X (Table S6, 261 tau > 0.54, p < 0.05 for all); X did not have an effect on Kendall's tau when considering the 262 entire time series (tau changed by < 0.05 as X varied). However, when considering the month of 263 June alone when COVID-19 incidence rate was relatively low, SARS-CoV-2 N gene 264 concentrations were positively and significantly correlated with 7-day smoothed COVID-19 265 incidence rates only when X > 1 ( = 0.1) and X did affect tau by as much as 0.15 (Table S7) . CoV-2 RNA N gene concentrations and COVID-19 incidence rate for all POTWs (Table 1) . As 274 there were not as many measurements that resulted in ND for X > 8, the confidence interval of 275 the logistic regression is relatively large, especially for X = 9 and 10. Therefore C0.5 derived for X 276 = 9 and10 is an extrapolation of the data used in this study and may be more uncertain. We measured concentrations of SARS-CoV-2 and PMMoV genes daily in wastewater settled 291 solids at four POTWs in California using ddRT-PCR during a period of time that 292 included both low and high COVID-19 incidence. We used 10 merged wells for the 293 measurements, and then determined how the measurement would have been affected by using 294 fewer than 10 wells through a down-sampling scheme. Our findings indicate that when a large 295 fraction of droplets are positive (> 5% positive), as was observed for PMMoV, a virus found in 296 high quantity in human stool and wastewater 16 , concentrations measured using just one well are 297 similar to those obtained using ten when considering the variability associated with the 298 measurements. On the other hand, when a smaller fraction of droplets are positive (< 0.5%), as 299 was the case for the SARS-CoV-2 gene measurements, using fewer wells can result in 300 measurements that may vary from those obtained using 10 wells, and more measurements 301 characterized as non-detects. 302 303 For the SARS-CoV-2 gene measurements, variability in measurements increased as the 304 number of wells decreased. Generally, we found that when the fraction of positive droplets was 305 greater than 0.024% (corresponding to a conservative approximate concentration of 10 4 cp/g 306 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint dry weight), that the variability in the measurement resulting from using 3 or more wells was 307 similar or smaller than the measurement total error obtained using 10 wells. In contrast, when 308 the fraction of positive droplets was less than 0.024%, the variability in the measurements 309 resulting from using 6 or more wells was similar or smaller than the measurement total error 310 obtained using 10 wells. These results could guide adaptive analysis plans that use fewer wells 311 to reduce costs when concentrations of SARS-CoV-2 are relatively high. 312 The probability of obtaining a non-detect increased as the SARS-CoV-2 gene concentration 314 decreased and the number of wells used in ddRT-PCR decreased. Using logistic regression, we 315 identified the concentration at which the detection frequency was less than 0.5 (C0.5), and this 316 value varies inversely with the number of wells; that is C0.5 is higher when fewer wells are used 317 for ddRT-PCR. This means that when low concentrations of SARS-CoV-2 genes are expected, 318 using too few wells can result in a large number of non-detects. For example, during the low 319 incidence period of June, if only 1 well had been used instead of 10, 92 of the 113 320 measurements across four POTWs would have been below C0.5. We found that at least 6 wells 321 were needed to achieve 90% of the measurements to be above C0.5 for June 2021. 322 323 Consistent with other studies, the wastewater concentration showed positive and significant 324 correlation with 7-day smoothed COVID-19 incidence rates. When there was variation in 325 COVID-19 incidence rates within the time frame being investigated (here before and during the 326 Delta variant surge), the number of wells being used for the analysis did not affect the 327 magnitude or statistical significance of the correlation. There was a positive and significant 328 correlation even when using only one well because there was enough variation in both 329 variables, although the majority of June measurements were characterized as non-detects. This 330 illustrates that finding a significant correlation between disease incidence and SARS-CoV-2 331 gene concentrations does not necessarily indicate good measurement sensitivity. It should be 332 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint noted that while we take the laboratory confirmed COVID-19 incidence rates to be reflective of 333 the level of COVID-19 that the community is experiencing, they are likely an underestimate of 334 incidence rates in the sewershed as the reported incidence rates are dependent on test-seeking 335 behavior and test availability 17 . 336 There are a few limitations of this analysis. First, in our analysis, we assumed that the 338 measurement obtained using 10 wells is the "true concentration" and compared all results 339 simulated with fewer than 10 wells to the true concentration and its error from the ddRT-PCR 340 instrument. Second, the results presented herein regarding assay sensitivity, and in particular 341 the C0.5 values in Table 1 are specific to the methods applied in this study. The relationship 342 between the number of wells used to the number of non-detects, and the lowest measurable 343 concentration will be impacted by the pre-analytical and analytical processes used. While the 344 specific values in Table 1 are not externally valid, unless others are using our exact methods 345 (available on protocols.io 18-20 ), the framework for examining the required sensitivity for 346 wastewater surveillance is. That is, careful attention to how sensitivity affects the lowest 347 measurable concentration and the number of non-detects, as well as the relationships between 348 these values and laboratory confirmed COVID-19 incidence rates is needed to fully understand 349 how decisions on assay implementation are made. 350 351 352 We developed and implemented a framework for examining how molecular assay sensitivity for 354 a viral RNA genome target affects its utility for wastewater-based epidemiology. The framework 355 involves understanding how assay sensitivity affects lowest measurable concentrations in units 356 of copies per environmental matrix mass, and the detection probability of a target that is 357 present; and how this change during periods of different disease occurrence can affect resultant 358 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint statistical associations between the viral target and measures of disease incidence. We applied 359 this framework to digital droplet RT-PCR (ddRT-PCR) measurements of a SARS-CoV-2 gene 360 made using 10 replicate wells, and determined how using fewer wells affected assay sensitivity 361 and its performance for wastewater-based epidemiology applications. From a reagent cost 362 savings perspective, we recommend an adaptive analytical approach where assay sensitivity is 363 increased by running more replicate wells (6 or more) during periods of low SARS-CoV-2 gene 364 concentrations (using our methods, < 10 4 cp/g) and COVID-19 incidence rate (< 3.5/100 000) 365 and fewer replicate wells (3 or more) during periods of higher SARS-CoV-2 RNA concentrations 366 and COVID-19 incidence. While the precise recommendations here are not generalizable, 367 unless one is using the same pre-analytical and analytical protocols, the framework and the 368 conclusion that adaptive approaches can reduce costs and increase sensitivity during periods of 369 low disease incidence can be applied to other methods and other wastewater-based 370 epidemiology targets. 371 372 Additional experimental, POTW (Table S1-S2) , and COVID-19 epidemiological data details; 374 simulation output (Table S3- . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. visualization. Each wastewater data point for X = 1 -9 represents median SARS-CoV-2 RNA 499 concentration for a single sample obtained from 1000 simulations; for X = 10, each data point is 500 the concentration obtained by merging 10 wells. Samples that resulted in ND were substituted 501 with zero. 502 503 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. concentration (x-axis), which is defined as concentration obtained by merging all ten wells. Each 509 data point shows the fraction of 1000 simulations that did not result in ND in each well on the y-510 axis and its true concentration on the x-axis. ND for X = 10 was substituted with half of the 511 theoretical lower measurement limit. 95% confidence intervals of the logistic regression are 512 shown as the gray ribbon. 513 514 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Each wastewater data point represents SARS-CoV-2 concentration measured for a single 521 sample. Samples above the lower measurement limit are shown as filled circles. Samples that 522 resulted in ND, shown as empty circles, were substituted with half the lower measurement limit. 523 524 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint 525 526 Tables 527 528 Table 1 . C0.5 shows the concentration that would yield a detect half the time in units of cp/g dry 529 weight, calculated using the logistic regression (Figure 3 ). % Samples under C0.5 shows 530 percentage of samples in the data set that were under C0.5 during the entire time series (All) and 531 the month of June when COVID-19 incidence rate was low (June). Incidence rate shows the 532 number of people out of 100,000 that corresponds to C0.5, calculated using the empirical 533 relationship between log-transformed SARS-CoV-2 RNA N gene concentrations and laboratory-534 confirmed COVID-19 incidence rates using 10 merged wells for all POTWs derived in Table S3 . 535 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted April 18, 2022. ; https://doi.org/10.1101/2022.04.17.22273949 doi: medRxiv preprint SARS-CoV-2 RNA in Wastewater Settled 431 Solids Is Associated with COVID-19 Cases in a Large Urban Sewershed Wastewater 435 Monitoring Outperforms Case Numbers as a Tool to Track COVID-19 Incidence 436 Dynamics When Test Positivity Rates Are High SARS-CoV-2 RNA Is Enriched by Orders of Magnitude in Primary Settled 442 Solids Relative to Liquid Wastewater at Publicly Owned Treatment Works Evaluation of Sampling, Analysis, and Normalization Methods for SARS-447 CoV-2 Concentrations in Wastewater to Assess COVID-19 Burdens in Wisconsin 448 Communities 451 The Environmental Microbiology Minimum Information (EMMI) Guidelines: QPCR and 452 DPCR Quality and Reporting for Environmental Microbiology Challenges in Measuring 456 the Recovery of SARS-CoV-2 from Wastewater Pepper Mild Mottle 459 Virus as an Indicator of Fecal Pollution Substantial Underestimation of SARS-CoV-2 Infection in the United States Analytical Processing of Wastewater Settled Solids for SARS-CoV-2 RNA Analyses V1 High Throughput RNA 469 Extraction and PCR Inhibitor Removal of Settled Solids for Wastewater Surveillance of 470 SARS-CoV-2 RNA V1 High Throughput SARS-472 COV-2, PMMOV, and BCoV Quantification in Settled Solids Using Digital RT-PCR V1