key: cord-0848262-26jvpwoz authors: van den Berg, Maarten; van der Hoeven, Hans title: In Patients with ARDS, Optimal PEEP Should Not Be Determined Using the Intersection of Relative Collapse and Relative Overdistention date: 2020-10-15 journal: Am J Respir Crit Care Med DOI: 10.1164/rccm.202006-2175le sha: e694f7621190b7ea8513cc2dde75131ad473a3bb doc_id: 848262 cord_uid: 26jvpwoz nan From the Authors: We thank van den Berg and van der Hoeven for the opportunity to further discuss our research letter in which positive end-expiratory pressure (PEEP) was titrated at the level of lowest relative alveolar overdistention and collapse based on electrical impedance tomography (EIT) (1). In their comment, the authors argue that PEEP should not be set at the minimum level of both alveolar overdistention and collapse, as alveolar overdistention is potentially more harmful. Electrical impedance tomography for positive end-expiratory pressure titration in COVID-19-related acute respiratory distress syndrome Individual positive end-expiratory pressure settings optimize intraoperative mechanical ventilation and reduce postoperative atelectasis Lung regional metabolic activity and gas volume changes induced by tidal ventilation in patients with acute lung injury Volutrauma and atelectrauma: which is worse? Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome Advanced respiratory monitoring in COVID-19 patients: use less PEEP!