key: cord-0847826-1snzwl2r authors: Naser Al Awaji, Nisreen; Talal Ahmedah, Hanadi; Mohammed Alsaady, Isra; Ahmed Bawaked, Rowaedh; Alraey, Mohammed A.; Ayed Alasiri, Ahmed; Mofareh Alfaifi, Abdullah; Ali Alshehri, Hamdan; Alserihi, Raed; Yasin, Elrashed B. title: Validation and Performance Comparison of Two SARS-CoV-2 IgG/IgM Rapid Tests date: 2021-03-14 journal: Saudi J Biol Sci DOI: 10.1016/j.sjbs.2021.03.007 sha: 6facb75641a4de95122d77e9bad9b7185850aa64 doc_id: 847826 cord_uid: 1snzwl2r Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes a disease called COVID-19. COVID-19 is primarily diagnosed using molecular techniques mainly real-time reverse transcriptase PCR. Reliable and accurate serologic assays for COVID-19, are an important tool for surveillance and epidemiologic studies. In this study, the IgG/IgM Rapid Test Cassette and the Prima COVID-19 IgG/IgM Rapid Test for the detection of SARS-CoV-2 antibodies in blood, serum and plasma samples collected from patients up to 48 days after symptom onset in Saudi Arabia were validated. Overall, both tests showed poor performance and cannot be utilised for COVID-19 diagnosis as a point of care test or to determine seroprevalence. Several novel viruses have emerged and caused serious diseases in the last two decadesincluding, severe acute respiratory syndrome coronavirus (SARS-CoV), H1N1 influenza and the Middle East respiratory syndrome coronavirus. Coronavirus disease 2019 (COVID-19) was first recorded in Wuhan, China, on 12th December 2019. On 30th January 2020, the World Health Organisation officially announced viral pneumonia as a public health emergency of international concern . On 11th March 2020, the World Health Organisation declared COVID-19 as a pandemic illness caused by SARS-CoV-2. SARS-CoV-2 is a highly contagious virus and has the same transmission routes as other respiratory infections -mainly by inhalation or contact with saliva and discharges or droplets. Its incubation period is estimated to be 2-14 days. However, further investigation is needed to understand the mode of transmission of the infection, as most of the information about the transmission is derived from similar respiratory coronaviruses (Rothe et al., 2020) . COVID-19's common symptoms are fever, cough, sore throat, breathlessness and fatigue, which are mainly mild. However, in more vulnerable individuals (the elderly with underlining diseases), the infection may advance to pneumonia, acute respiratory distress syndrome and cytokine storm -leading to multiorgan dysfunction and, subsequently, death . At the time of writing this article, the latest figures indicate that there are more than 108 million confirmed cases of COVID-19 around the globe and more than two million deaths (World Health Organization, 2020a). In Saudi Arabia, there are more than 372,000 confirmed cases and more than 6,000 deaths (World Health Organization, 2020b). A proper diagnosis of the infection plays a critical role in the treatment and control of the disease, and real-time reverse transcription-polymerase chain reaction (RT-PCR) assays remain the preferred molecular test for the diagnosis of SARS-CoV-2 infection (Loeffelholz and Tang, 2020) . However, serology-based assays are being used as an additional method to RT-PCR. The development of accurate serologic assays that can profile the antibodies against SARS-CoV-2 to detect the previous infection and acquired immunity will be essential for epidemiologic seroprevalence studies and vaccine assessments and has potential for risk assessment of health-care workers. Several immunoassays are commercially available in some countries -although the diagnostic accuracy and specificity of these kits, which are needed to define the optimal use of these kits, are undefined (World Health Organization, 2020c). Up to date, COVID-19 infection rate data mostly cover acute clinical infections with respiratory symptoms, while the number of subclinical infections and atypical patients remains undetermined (Lerner et al., 2020) . Therefore, serological COVID-19 detection will help in the This study aimed to compare and evaluate the performance of two commercially available serological assays for the detection of SARS-Cov-2 antibodies: Prima COVID-19 IgG/IgM Rapid Test (PRIMA Lab SA, Balerna, Switzerland) and Innovita 2019-nCoV Ab Test (Innovita Biological Technology, China). Both assays were tested against the same panel of serology samples from patients with confirmed COVID-19 and a group of negative control samples. To investigate the sensitivity and specificity of the and clinical data on admission were extracted from medical records. Whole blood, plasma, or serum were used to test the IgM and IgG antibodies. The test was performed following the operation method described in the product inserts. A qualitative detection and differentiation test of IgM and IgG antibodies against SARS-CoV-2 in whole blood, serum or plasma from individuals suspected of COVID-19 who had COVID-19 positive and negative samples, which was confirmed with RT-PCR method, was done. The Hospital upon the admission of the patient. Serum (10 μL), plasma sample or 20 μL whole blood sample were added to the sample well(S) on the cassette. Then we added two drops of buffer (approximately 80 L), started the timer, and then read the results at 10 minutes, as the results cannot be interrupted after 20 minutes. Statistical analysis was performed with the Statistical Analysis System software (SPSS). The specificity, sensitivity, positive and negative predictive values and accuracy of the rapid test kits were calculated according to the following formulas: Specificity ( This study aimed to investigate the performance of two commercially available kits that are By looking at the performance of the kit at different duration after the onset of the symptoms, the results indicate that the performance of the kit improved after 16 days post-onset of the symptoms. The sensitivity of the kits was 12%-44% for samples collected 7-16 days after the onset of the symptoms and 64%-93% for the samples collected between 16-48 days after the onset of the symptoms (Table 3) . However, the performance of the two kits was below the acceptable range (< 95%). In terms of the duration of more than 48 days, there was only one available sample; therefore, this result is not representative. Few weeks after the outbreak of COVID-19, several manufacturers began promoting POCT for detecting SARS-CoV-2 antibodies. But, to date, only a few studies have been conducted to check the viability and validity of these commercial kits in the management of the COVID-19 outbreak. Therefore, this study aimed to evaluate the performance of the two diagnostic kits by comparing their result to RT-PCR. The results showed that both kits have poor sensitivity. Prima kit showed good specificity for the detection of IgM but the overall specificity was below the required level. Similarly, the Innovita kit showed poor specificity. Thus, both kits are not appropriate for diagnostic or research use. The accuracy and significance of the serological test is dependent on the detection day, to ensure the detection of IgM and IgG after their onset. The SARS-CoV host antibodies are detectable after several days to weeks. A study investigated the median time from symptom onset to antibody detection by using an enzyme-linked immunosorbent assay that reacts with antibodies against the receptor-binding domain of the spike protein. The result showed that IgM was detected by day 12, while IgG was detected by day 14 after the onset of the symptoms. By day 15, the detection rate of IgM and IgG were 94% and 80%, respectively . The results of the current study are consistent with the findings of other studies (Qu et al., 2020) . Therefore, serologic tests may be able to identify some patients with current infection (particularly those who present late in the course of illness), but they are less likely to be reactive in the first several days to weeks of infection. Thus, it may have less utility for diagnosis in the acute setting . On the other hand, a systemic meta-analysis that assessed the performance of serological diagnosis of COVID-19 revealed that using an enzyme-linked immunosorbent assay had better performance -that is, higher sensitivity and specificity than POCT (Lisboa Bastos et al., 2020) . In addition, automated chemiluminescent immunoassay has shown greater sensitivity and specificity and is now used as a golden standard for COVID-19 serological detection (Noce et al., 2020) . Also, the accuracy and the rate of cross-reactivity with other respiratory viruses, especially other coronaviruses, is a potential concern, as cross-reactivity with these viruses has been reported, although the overall specify was in the acceptable range (Charlton et al., 2020) . The sensitivity and the specificity of POCT kits vary between different manufacturers (Lassaunière et al., 2020) (Charlton et al., 2020) . Some studies have found that POCT were not significantly accurate -for example, the UK and Spain authorities have rejected the use of these POCT for seroprevalence. The American Society for Microbiology, the Public Health Agency of Canada and the WHO have also published recommendations against using serology testing for the diagnosis of acute infection (Patel et al., 2020) . The Saudi center of disease prevention and control (SCDC) that laboratories in order to provide diagnostic testing for COVI-19, the laboratory should use nucleic acid based detection system. Furthermore, Cassaniti et al. (Cassaniti et al., 2020) found that the sensitivity of one of these rapid tests was < 20%, and these results align with findings reported elsewhere (Döhla et al., 2020) , indicating that some rapid tests have been commercialised without significant clinical and analytical validation. Therefore, it is recommended that all commercial serological rapid tests be appropriately validated clinically before routine clinical usage. However, these kits can be used to support PCR results but should not replace them (Lippi et al., 2020) . Our results showed an increase in the sensitivity of the rapid test kits after 16 days. This finding has been observed in some studies (Lassaunière et al., 2020) (Riccò et al., 2020) . Charlton et al. described the performance of serological assays as unreliable before 14 days; however, improves over time, and the antibodies can be detected up to day 45 (Charlton et al., 2020) . However, this delay in detecting antibodies, especially IgM, limits the use of the kit for diagnosis purposes, as the majority of patients with SARS-CoV-2 are asymptomatic. Thus, the symptoms of patients with mild infections may be undiagnosed and their onset cannot be estimated, or patients may be tested in an early stage of the SARS-CoV-2 infection. The limitation of this study was the inability to obtain the samples during the IgG and IgM onset, although this did not apply to some samples. Patients that tested positive for COVID-19 were hospitalised; therefore, patients with mild symptoms or asymptotic were not included in this analysis. Studies have shown that the timeline for the detection of immune-response antibodies (serological diagnosis) is very critical to give accurate serological test results. The antibodies can be detected eight days after the symptoms appear (Lerner et al., 2020) . In this study, the timing of the diagnosis was one of the most important limiting factors because it was difficult to get the samples at the appropriate time due to the hospital restricted protocol. The blood samples were collected at the time of visiting, which ranged from 5 to 8 days after the symptoms appear. In some complicated cases, the patients were admitted and another blood samples were collected before they were discharged from the hospital. Inappropriate diagnostic timing may lead to false-negative results, especially at an early stage of infection. In our study the number of samples available for follow up after 16 days were decreased to <15 samples. in covid 19 a significant point is how long antibodies persist in the blood, therefore bigger number of follow up sample will be helpful to clarify this point. Another limitation of our study is that all the patients that were positive for COVID-19 were hospitalised; therefore, patients with mild symptoms or asymptotic were not included in this analysis. As shown in other studies, patients with severe clinical symptoms had higher IgG antibody levels than patients with mild symptoms (Okba et al., 2020) (Klein et al., 2020) (Yongchen et al., 2020) . Here, we report a serology panel consisting of serum from patients tested positive for COVID-19 and those tested negative. We compared the performance of two different commercial POCT with the same serum panel to give an accurate comparison across all platforms. Our results showed that POCT antibody detection for COVID-19 should not be used for the diagnosis of acute infections nor for serosurveys to facilitate estimation of seroprevalence in a population and identify previous exposure to the virus. Also, it is not recommended for research use. Performance of VivaDiag COVID-19 IgM/IgG Rapid Test is inadequate for diagnosis of COVID-19 in acute patients referring to emergency room department Evaluation of six commercial mid-To high-volume antibody and six point-of-care lateral flow assays for detection of SARS-CoV-2 antibodies Molecular Diagnosis of a Novel Coronavirus (2019-nCoV) Causing an Outbreak of Pneumonia Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Rapid point-of-care testing for SARS-CoV-2 in a community screening setting shows low sensitivity Profiling early humoral response to diagnose novel coronavirus disease (COVID-19) The origin, transmission and clinical therapies on coronavirus disease 2019 (COVID-19) outbreak -an update on the status Sex, age, and hospitalization drive antibody responses in a COVID-19 convalescent plasma donor population Evaluation of nine commercial SARS-CoV-2 immunoassays 1-15 The COVID-19 Serology Studies Workshop: Recommendations and Challenges Current laboratory diagnostics of coronavirus disease 2019 (COVID-19) Diagnostic accuracy of serological tests for covid-19: Systematic review and meta-analysis Laboratory diagnosis of emerging human coronavirus infectionsthe state of the art Serological determinants of COVID-19 Severe Acute Respiratory Syndrome Coronavirus 2-Specific Antibody Responses in Coronavirus Disease Patients Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients Profile of Immunoglobulin G and IgM Antibodies Against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Point-of-Care Diagnostic Tests for Detecting SARS-CoV-2 Antibodies: A Systematic Review and Meta-Analysis of Real-World Data Transmission of 2019-nCoV Infection from an Asymptomatic Contact in Germany A novel coronavirus outbreak of global health concern World Health Organization, 2020a. Coronavirus disease (COVID-19) outbreak situation 2020-Overview 2020 World Health Organization, 2020b. World Health Organization. Coronavirus disease (COVID-19) outbreak situation 2020 World Health Organization, 2020c. World Health Organization. Laboratory testing for coronavirus disease (COVID-19) in suspected human cases 2020 Different longitudinal patterns of nucleic acid and serology testing results based on disease severity of COVID-19 patients Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease The authors extend their appreciation to the Deputyship for Research& Innovation, Ministry The authors declare that they have no competing interests. HTA and NNA conceptualised the study. IMA and RAB searched the literature. MAA and AAA collected the data. RFA, IMA and EBY helped prepare the manuscript. HTA, NNA and RAB refined the manuscript for publication. All authors read and approved the final manuscript for publication.