key: cord-0843116-1c3u1bcm authors: Quaresima, Valentina; Ferrari, Marco title: COVID-19: efficacy of prehospital pulse oximetry for early detection of silent hypoxemia date: 2020-08-13 journal: Crit Care DOI: 10.1186/s13054-020-03185-x sha: b29f42b68bfd6f7a4d56282c455043c144c1f1ce doc_id: 843116 cord_uid: 1c3u1bcm nan COVID-19: efficacy of prehospital pulse oximetry for early detection of silent hypoxemia Valentina Quaresima and Marco Ferrari * We read with interest the research letter published in Critical Care by Jouffroy et al. who suggest the utility of prehospital pulse oximetry as a red flag for early detection of silent hypoxemia in COVID-19 patients [1] . Fingertip pulse oximeters are one of the most widely used medical standard monitoring tools to assess oxygenation and respiratory function in patients. In fact, a pulse oximeter noninvasively measures arterial blood oxygen saturation (SpO 2 , %), and it represents an accessible tool that can be easily used by patients, physicians, and prehospital healthcare providers. However, it is important to ensure that the used pulse oximeter has a high accuracy, especially when SpO 2 is lower than 90%. The accuracy criteria for the pulse oximeter equipment are provided in the International Standard ISO 80601-2-61 [2], and the U.S. Food and Drug Administration (FDA) only permits pulse oximeters that meet these criteria [3] . According to the ISO 80601-2-61, the SpO 2 accuracy of a pulse oximeter should be assessed through a controlled desaturation study by comparing the SpO 2 measurements with the gold standard measurements of blood arterial oxygen saturation (SaO 2 ) obtained by a CO-oximeter. The prices for home pulse oximeters range from $20 to $80, and not all pulse oximeters are built with the same performances and the required FDA's accuracy. Few of them have the FDA's approval. A recent study on the accuracy of six low-cost pulse oximeters, not cleared by the FDA, has demonstrated highly inaccurate readings, even if some of them surprisingly performed likewise the expensive clinical pulse oximeters during voluntary hypoxia [4] . Some COVID-19 patients suddenly develop the condition called "silent hypoxia," during which they still look and feel comfortable, but their SpO 2 is perilously low. This happens to patients either in the hospital or at home. Low SpO 2 may indicate severe COVID-19-related pneumonia, requiring a ventilator. A useful practical guidance for the correct use of pulse oximetry for monitoring patients with COVID-19 at home have been very recently published [5] . SpO 2 self-monitoring by patients with non-severe COVID-19, discharged from the emergency department or an outpatient testing center, is an essential way to identify patients needing to return to the hospital for a further evaluation. However, considering the largely unregulated low-cost pulse oximetry market, physicians should pay attention to incorporating SpO 2 data, obtained from pulse oximeters not cleared [3] by the FDA, the European Medicine Agency or other regulatory agencies, for making medical decisions. Reply to Quaresima et al.: "COVID-19: efficacy of prehospital pulse oximetry for early detection of silent hypoxemia" Dear Editor, We thank Quaresima et al. [6] for their interest and relevant comments about the early detection of silent hypoxemia in COVID-19 patients based on prehospital pulse oximetry [1] . We agree that fingertip pulse oximeters may only provide approximate measurements of arterial blood oxygen saturation and that many intrinsic and extrinsic factors influence pulse oximetry values [6, 7] beyond the preanalytical conditions required for certification [8] . One particularity of COVID-19-related acute respiratory failure was that, despite low blood oxygen concentration, the respiratory rate frequently remained close to normal, unlike in other acute respiratory failure etiologies [9] . Our observational study was not designed to assess pulse oximetry for medical decision making but was intended to detect "silent hypoxemia" in suspected COVID-19 patients. Furthermore, the Paris Fire Brigade basic life support teams used a device complying with the European Union's Medical Device Regulation of 2017. Quaresima et al. remind us that rescuers must continuously be aware of the technical limitations of the equipment they use in their daily practice. :313. 2. International Standard. ISO 80601-2-61:2017. Medical electrical equipment -Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment Premarket Notification Submissions [510(k)s]: Guidance for Industry and Food and Drug Administration Staff The accuracy of 6 inexpensive pulse oximeters not cleared by the Food and Drug Administration: the possible global public health implications Pulse oximetry for monitoring patients with COVID-19 at home: potential pitfalls and practical guidance COVID-19: efficacy of prehospital pulse oximetry for early detection of silent hypoxemia Transcutaneous oxygen measurements: implications for nursing Preanalytical processes in medical diagnostics: new regulatory requirements and standards The regulation of normal lung function None. Both authors conceived the idea for the letter and drafted the manuscript. The authors read and approved the final manuscript. None. Availability of data and materials Not applicable.Ethics approval and consent to participate Not applicable. Not applicable. The authors declare that they have no competing interests.Received: 17 June 2020 Accepted: 16 July 2020