key: cord-0842468-12wlyyxs authors: Pelosi, Paolo; Tonelli, Roberto; Torregiani, Chiara; Baratella, Elisa; Confalonieri, Marco; Battaglini, Denise; Marchioni, Alessandro; Confalonieri, Paola; Clini, Enrico; Salton, Francesco; Ruaro, Barbara title: Different Methods to Improve the Monitoring of Noninvasive Respiratory Support of Patients with Severe Pneumonia/ARDS Due to COVID-19: An Update date: 2022-03-19 journal: J Clin Med DOI: 10.3390/jcm11061704 sha: 918c13489f9a0a3ddcbe9586409a0925cc561bcf doc_id: 842468 cord_uid: 12wlyyxs The latest guidelines for the hospital care of patients affected by coronavirus disease 2019 (COVID-19)-related acute respiratory failure have moved towards the widely accepted use of noninvasive respiratory support (NIRS) as opposed to early intubation at the pandemic onset. The establishment of severe COVID-19 pneumonia goes through different pathophysiological phases that partially resemble typical acute respiratory distress syndrome (ARDS) and have been categorized into different clinical–radiological phenotypes. These can variably benefit on the application of external positive end-expiratory pressure (PEEP) during noninvasive mechanical ventilation, mainly due to variable levels of lung recruitment ability and lung compliance during different phases of the disease. A growing body of evidence suggests that intense respiratory effort producing excessive negative pleural pressure swings (P(pl)) plays a critical role in the onset and progression of lung and diaphragm damage in patients treated with noninvasive respiratory support. Routine respiratory monitoring is mandatory to avoid the nasty continuation of NIRS in patients who are at higher risk for respiratory deterioration and could benefit from early initiation of invasive mechanical ventilation instead. Here we propose different monitoring methods both in the clinical and experimental settings adapted for this purpose, although further research is required to allow their extensive application in clinical practice. We reviewed the needs and available tools for clinical–physiological monitoring that aims at optimizing the ventilatory management of patients affected by acute respiratory distress syndrome due to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection. The coronavirus disease pandemic, caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, is still overwhelming global healthcare systems due to the huge spread of a life-threatening pneumonia that as of 25 January The coronavirus disease pandemic, caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, is still overwhelming global healthcare systems due to the huge spread of a life-threatening pneumonia that as of 25 January 2022 has caused more than 5,832,333 recognized deaths worldwide [1] . The guidelines for the hospital care of patients affected by COVID-19-related acute respiratory failure (ARF) have moved from a prevalent early intubation approach to the widely accepted use of noninvasive respiratory support methods, such as high-flow nasal cannula (HFNC) and noninvasive continuous positive airway pressure (CPAP) and positive pressure ventilation (NIV) [1, 2] . This change in the management of the disease has been due to the limited availability and higher cost of intensive care unit (ICU) beds, as well as to the positive results obtained with corticosteroids and noninvasive respiratory support (NIRS) in several published trials [2] . However, the severity of COVID-19 pneumonia and the risk of underestimating the potential dangers of a uselessly prolonged NIRS prompted us to summarize the need for the strict clinical-physiological monitoring of patients affected by severe COVID-19 pneumonia or acute respiratory distress syndrome (ARDS) based on serial imaging techniques and physiological measurements [1, 2] . The objective of this narrative review is to discuss the needs and available tools for clinical-physiological respiratory monitoring that aims at optimizing the respiratory assistance and the ventilatory management of patients affected by ARDS due to SARS-CoV-2 infection. Legend. Pulmonary ARDS: in supine position, low ventilation/perfusion ratio (V/Q) is prevalent. Higher regional perfusion and true shunt are mostly diverted in the dependent lung regions. Extrapulmonary ARDS: in supine position, true shunt is prevalent with possible alveolar collapse. The pulmonary blood flow and shunt mainly distribute toward the dependent lung regions. COVID-19 phenotype 1: in supine position, a low V/Q is prevalent with anti-gravitational distribution of pulmonary blood flow. COVID-19 phenotype 2: in supine position, true shunt is increased, while the pulmonary blood flow is anti-gravitational. V/Q, ventilation/perfusion; COVID-19, coronavirus disease 2019; ARDS, acute respiratory distress syndrome. regions. Extrapulmonary ARDS: in supine position, true shunt is prevalent with possible alveolar collapse. The pulmonary blood flow and shunt mainly distribute toward the dependent lung regions. COVID-19 phenotype 1: in supine position, a low V/Q is prevalent with anti-gravitational distribution of pulmonary blood flow. COVID-19 phenotype 2: in supine position, true shunt is increased, while the pulmonary blood flow is anti-gravitational. V/Q, ventilation/perfusion; COVID-19, coronavirus disease 2019; ARDS, acute respiratory distress syndrome. Legend. Pulmonary ARDS: in prone position, oxygenation may improve due to partial redistribution of pulmonary blood flow toward ventral regions, and not by effective alveolar recruitment. This might be associated with decreased carbon dioxide washout. Extrapulmonary ARDS: in prone position, oxygenation can improve because of possible alveolar recruitment of collapsed alveoli, while maintaining perfusion higher toward the dorsal lung regions. COVID-19 phenotype 1: in prone position, oxygenation may improve, partially redistributing pulmonary blood flow that remains anti-gravitational. COVID-19 phenotype 2: in prone position, oxygenation may improve, partially redistributing pulmonary blood flow from dorsal to ventral lung regions, and not by effective alveolar recruitment. This might be associated with decreased carbon dioxide washout. V/Q, ventilation/perfusion; COVID-19, coronavirus disease 201; ARDS, acute respiratory distress syndrome. Gas-exchange is determined by ventilation and perfusion. Normal lung areas present a normal ventilation and perfusion (V/Q) ratio. In pathological conditions, major alterations may occur, explaining worsening in oxygenation: (1) increased lung regions with decreased ventilation to perfusion ratio from 0.1 to 0.001 (low V/Q ratio), and (2) non ventilated but perfused ("true shunt") lung regions. The sum of the low V/Q and lung regions with "true shunt" determines the so called "venous admixture" [5] [6] [7] . The hypoxia due to low V/Q ratio may improve by administration of increased inspiratory oxygen fractions, while hypoxia due to "true shunt "does not improve by administration of increased inspiratory oxygen fractions. On the other side, lung regions with higher ventilation to perfusion ratio or ventilated but not perfused ("dead space") increase the "wasted ventilation" leading to ineffective respiratory effort for carbon dioxide (CO2) washout. These lung regions do not substantially affect oxygenation [5] [6] [7] . Legend. Pulmonary ARDS: in prone position, oxygenation may improve due to partial redistribution of pulmonary blood flow toward ventral regions, and not by effective alveolar recruitment. This might be associated with decreased carbon dioxide washout. Extrapulmonary ARDS: in prone position, oxygenation can improve because of possible alveolar recruitment of collapsed alveoli, while maintaining perfusion higher toward the dorsal lung regions. COVID-19 phenotype 1: in prone position, oxygenation may improve, partially redistributing pulmonary blood flow that remains anti-gravitational. COVID-19 phenotype 2: in prone position, oxygenation may improve, partially redistributing pulmonary blood flow from dorsal to ventral lung regions, and not by effective alveolar recruitment. This might be associated with decreased carbon dioxide washout. V/Q, ventilation/perfusion; COVID-19, coronavirus disease 201; ARDS, acute respiratory distress syndrome. Gas-exchange is determined by ventilation and perfusion. Normal lung areas present a normal ventilation and perfusion (V/Q) ratio. In pathological conditions, major alterations may occur, explaining worsening in oxygenation: (1) increased lung regions with decreased ventilation to perfusion ratio from 0.1 to 0.001 (low V/Q ratio), and (2) non ventilated but perfused ("true shunt") lung regions. The sum of the low V/Q and lung regions with "true shunt" determines the so called "venous admixture" [5] [6] [7] . The hypoxia due to low V/Q ratio may improve by administration of increased inspiratory oxygen fractions, while hypoxia due to "true shunt "does not improve by administration of increased inspiratory oxygen fractions. On the other side, lung regions with higher ventilation to perfusion ratio or ventilated but not perfused ("dead space") increase the "wasted ventilation" leading to ineffective respiratory effort for carbon dioxide (CO 2 ) washout. These lung regions do not substantially affect oxygenation [5] [6] [7] . Non-COVID-19 ARDS may be distinguished in "pulmonary" or "extrapulmonary" different phenotypes [8] that show distinctive histopathological features but are difficult to separate due to their overlap in clinical manifestations, being that most patients with pneumonia are also characterized by sepsis [8] . The "pulmonary" ARDS phenotype is characterized by a direct insult to the lung structure; it is mainly caused by pneumonia, leading to increased damage of the alveolar epithelium, prevalent neutrophils and fibrinous alveolar infiltrates, prevalent increases in compartmentalized inflammatory mediators, less interstitial and alveolar edema, normal capillary endothelium, and moderate increases in systemic inflammatory mediators. The more consolidated lung regions cause an increase of lung weight, while hypoxia is mainly due to variable distribution of ventilation and perfusion, depending to the pattern of lung injury (combination of low V/Q as well as "true shunt" lung areas). In this phenotype, higher positive end-expiratory pressure (PEEP) may lead to greater redistribution of ventilation and perfusion toward the non-dependent lung regions, with marked over-inflation of healthy lung regions. Prone position may improve oxygenation, mainly by partially redistributing pulmonary blood flow from dorsal to ventral lung regions and not by effective alveolar recruitment. This might be associated with decreased CO 2 washout, since no increase in effective alveolar ventilation is expected [9, 10] . On the contrary, the "extrapulmonary" ARDS phenotype is characterized by an indirect insult to the lung structure, and it is mainly caused by sepsis, leading to decreased damage of the alveolar epithelium, decreased neutrophils and fibrinous alveolar infiltrates, less compartmentalization of inflammatory mediators, higher interstitial and alveolar edema, altered capillary endothelium, and major increases in the systemic inflammatory mediators. Increased lung weight is also consistent in "extrapulmonary" ARDS, but it is due to higher edema, leading to predominant alveolar collapse in the dependent lung regions in the supine position, associated with a gravitational distribution of perfusion; thus, hypoxia is prevalently due to true shunt. Higher PEEP may lead to effective alveolar recruitment, with greater redistribution of ventilation and perfusion toward the dependent lung regions, with less over-inflation of non-dependent lung regions. Prone position may improve oxygenation, mainly by recruitment of collapsed lung regions, while maintaining perfusion higher toward the dorsal lung regions. This might be associated with increased CO 2 washout, since effective improvement in regional alveolar ventilation is expected [9, 10] . Therefore, in traditional ARDS, higher regional perfusion and "true shunt" are mostly diverted to the dependent lung regions as edema is formed toward a ventral-dorsal gradient [11] [12] [13] . This causes the pressure applied on dependent lung regions to favor progressive atelectasis formation, while PEEP application keeps the dependent alveoli open, improving gas exchange and respiratory system compliance [11] [12] [13] . COVID-19 ARDS may be considered as a typical example of "primary" ARDS not associated with sepsis, at least in the initial stages. In COVID-19 ARDS, non-dependent aerated regions are mostly perfused, thus justifying a certain degree of hypoxic vasoconstriction in the dependent lung regions, resulting in a non-gravitational distribution of regional blood flow [13] . Unlike typical ARDS, in COVID-19, the lung compliance system does not deteriorate rapidly but gas-exchange impairment and hypoxia predominantly occur due to micro-thrombosis, dead space, and low V/Q lung regions [12] [13] [14] [15] . In fact, COVID-19 ARDS is described by two different phenotypes (1 and 2) that represent an evolution of lung injury. Phenotype 1, typical of the early stages of the disease, is characterized by minor increases in lung weight, mainly due to poorly aerated (groundglass radiological pattern) or consolidated lung regions, greater presence of aerated lung tissue, and minor changes in the respiratory and lung compliance, while hypoxia is mainly due to increased lung areas with low V/Q ratio due to lower ventilation in poorly aerated regions and/or increased perfusion in normally and poorly aerated lung regions. In this phase, beneficial response to higher oxygen fraction and effectiveness of non-invasive respiratory support is observed [14] [15] [16] [17] . With the evolution of lung injury towards phenotype 2, the decrease in aerated lung regions and the increase in non-aerated but perfused ones lead to increased shunt, while the reduction in perfusion of non-aerated regions may limit the severity of hypoxia [17] . Phenotype 2 is characterized by a further reduction in aerated lung surface with a progressive reduction in the lung compliance, greater increase in the lung weight mainly due consolidated lung regions and non-perfused areas that become predominant. This causes the blood flow redistribution to these injured areas, leading to a worsening in oxygenation that can be caused by hypoxic vasoconstriction, thrombotic obstruction, or compression of capillaries [17] . Thus, the distribution of perfusion in COVID-19 ARDS follows a reverse gravitational pattern with a higher blood volume distributed in aerated (ventral) lung areas [13, 15, 17] . In this phase, no beneficial response to higher oxygen fraction and no effectiveness of non-invasive respiratory support is observed, while demanding prompt intubation if gas-exchange deteriorates and inspiratory effort increases [15, 16, 18] . The recruitment of COVID-19 ARDS (ranging from 1 to 6% of total lung weight) was lower than that reported in non-COVID-19 ARDS (ranging from 8% to 25% of lung weight [19, 20] . Ball et al. showed that non-aerated tissue was reduced by increasing PEEP from 8 to 16 cmH 2 O, while normally aerated and hyper-aerated tissues increased both in recruiters and non-recruiters, and poorly aerated tissue decreased only in non-recruiters [20] . Moreover, alveolar recruitment was independent from the respiratory system compliance, and it slightly changed from 8 to 16 cmH 2 O of PEEP. Recruitment was prevalent in the dependent and caudal regions, but it did not correlate with the lung weight (which is associated with non-aerated tissue), changes in laboratory parameters, gas-exchange, and respiratory mechanics [20] . Higher PEEP decreased respiratory system compliance and improved oxygenation only at FiO 2 50% but not higher. Indeed, higher PEEP may lead to greater redistribution of ventilation and perfusion toward the non-dependent lung regions, with marked over-inflation of healthy lung regions. Prone position may improve oxygenation, mainly by partially redistributing pulmonary blood flow from dorsal to ventral lung regions, and not by effective alveolar recruitment. This might be associated with decreased CO 2 washout, since no increase in effective alveolar ventilation is expected [15] [16] [17] . These findings support the hypothesis that the excess of lung weight in COVID-19 ARDS is not due to edema, and that PEEP might improve oxygenation by acting more on V/Q matching in areas with low V/Q than on alveolar recruitment [20] . Severe COVID-19 pneumonia shares several histological and imaging features with non-COVID-19 ARDS, since both are characterized by inflammatory lung injury, progressive parenchymal stiffening and consolidation, alveolar and airway collapse, altered vascular permeability, and a pathological picture of diffuse alveolar damage (DAD) [4] . Usually, three histopathological phases are described in traditional ARDS: (1) acute early exudative (1-7 days) with intra-alveolar edema, interstitial widening, formation of hyaline membranes, epithelial disruption, and alveolar distortion; (2) subacute proliferative phase (1-3 weeks) with myofibroblast proliferation and hyperplasia of the epithelial lining; and (3) late fibrotic phase (>3 weeks) characterized by collagen deposition, progressive obliteration of alveolar spaces, and interstitial fibrosis [4] . Associated thrombi can result as expression of an altered coagulation cascade, which is common in COVID-19 [3] (Table 1) . In the monitoring of severe COVID-19, imaging techniques play a pivotal role. Chest Xray and computed tomography (CT) scan are useful for diagnosis and clinical management, usually showing coexistence of typical aspects of viral pneumonia (i.e., ground glass opacities with or without consolidations and crazy-paving opacities with a subpleural distribution) and ARDS features (Figure 3) . From a clinical point of view, distinct chest CT patterns have been categorized into different COVID-19 phenotypes that can benefit from different clinical management: phenotype 1 (or type L, characterized by low elastance, high lung compliance, low ventilation/perfusion ratio, low weight, low recruitability) [21, 22] , typical of mild to moderate disease that can initially benefit from noninvasive respiratory support, presents as multiple, often bilateral, focal over-perfused ground glass opacities and normally aerated zones; phenotype 2 (or type H, i.e., high elastance, low lung compliance, high ventilation/perfusion ratio, high lung weight, high recruitability) [21, 22] , more typical of the most severe COVID-19, shows non-homogeneously distributed hyper-and hypoperfused areas with predominant atelectasis and a patchy ARDS-like pattern [16, [22] [23] [24] Several studies reported that phenotype L is most frequent (70-80% of patients) than phenotype H (20-30%) [12, [21] [22] [23] [24] . In their study, Gattinoni et al. reported that the transition from phenotype L to type H may be due to both the evolution of COVID-19 pneumonia and the injury attributable to high-stress ventilation. The same group concluded that type L and H are best identified by CT scan, which could be useful also to recognize other possible comorbidities [12] . In line with recent assumptions, the proposed COVID-19-related phenotypes may be considered as the two extremes of a unique evolving disease [21] [22] [23] [24] . A recent article demonstrated that phenotype H was more common among females and was associated with a higher risk of ARDS and burden of comorbidities, including diabetes. Furthermore, patients classified as phenotype H were liberated from mechanical ventilation later and characterized by higher mortality as compared to phenotype L patients [12, [21] [22] [23] [24] . Finally, phenotype 3 (fibroproliferative) includes the low-specificity CT findings of an advanced COVID-19 pneumonia, where a dysregulated fibrotic response follows the extensive damage to lung scaffold and vasculature [23, 24] . The necessity to develop radiological tools which can predict which patients are at higher risk for development of a rapid and fatal progression of the disease during the acute phase quickly emerged. Severity scores based on chest X-ray [25, 26] or CT scan have been proposed to stratify the patients by quantifying the extension of the disease and to predict both the need for ICU referral and death at the time of hospital admission [27, 28] . The radiological long-term findings are represented by interlobular septal thickening, reticular opacities, and subpleural curvilinear opacities in association with bronchial dilatation and distortion ( Figure 3 , Table 1 ). Reticulations (fibrotic-like changes) can either be an early sign of post-ARDS fibrosis, as described in previous coronavirus outbreaks (SARS and Middle East respiratory syndrome, MERS), or they can be related to the evolution of the organizing pneumonia [29] . In SARS-CoV-2 infection complicated by ARDS [30] , phenotype 3 is found in 35% [31] to 72% [32] of patients at six months follow-up. On the contrary, the incidence of pulmonary fibrosis was about 4% during previous coronavirusrelated epidemics [33] , while it reached 25% [34] after H1N1 pneumonia. Several factors have been correlated with the risk of developing fibrosis and persistent functional deficit in COVID-19, i.e., the severity of infection, the need for ICU admittance and mechanical ventilation, older age, higher body mass index, and smoking history [29, 35] . Hence, patients who recover from SARS-CoV-2 related ARDS but experience persistent respiratory symptoms need to undergo a radiological follow-up to determine whether alterations that can anticipate the establishment of fibrosis exist [29] . Despite high resolution CT (HRCT) being considered the gold standard for diagnosis, staging, and follow-up of COVID-19 [36] [37] [38] , it requires patient transportation and radiation exposure. Thanks to the elevated sensitivity and specificity of ultrasound in the field of pleural, parenchymal, and interstitial abnormalities, the whole international literature considers lung ultrasound (LUS) a useful support for the diagnosis of COVID-19 pneumonia in the emergency setting as well as for the clinical and therapeutic follow-up [39] [40] [41] [42] [43] [44] [45] . Indeed, LUS can be easily used at a patient's bed without X-ray exposure, and it can be repeated several times, for example in pregnant women and children [46] . In patients with COVID-19 pneumonia, also during the preclinical period, a specific LUS pattern is represented by pleural thickening, pleural interruptions and effusions, multifocal B lines, and small opacities [46] [47] [48] [49] . To date, there is no single established algorithm for performing LUS in patients with COVID-19 disease, despite several approaches having been proposed, such as scanning 12-, 14-, or 16-lung zones [46] [47] [48] [49] . Several studies showed that in COVID-19 pneumonia still at an early stage, LUS can detect early lung lesions even when CT scan is almost normal. Furthermore, there was a relationship between the abnormalities detected by the LUS and CT, especially between the presence of more than 2 B-lines on LUS and ground glass opacity areas on CT and between subpleural consolidations on LUS and consolidation areas on CT [36] [37] [38] 50] . Recently, Lupia et al. enrolled 208 patients with COVID-19 respiratory symptoms who underwent nasal swab and LUS according to a scanning protocol [47] . In 20% of patients who had a false negative nasal swab, ultrasound showed typical parenchymal abnormalities for COVID-19. Due to the persistence of pathological ultrasound aspects after the acute phase, thoracic ultrasonography has also been chosen among the tools for COVID-19 followup after patient discharge [47, 51] . Thus, when combined with clinical data, LUS can provide a potent monitoring aid in patients with suspected COVID-19 pneumonia, reflecting and anticipating CT findings. However, LUS does not add much value in determining invasive versus non-invasive management in these patients, and it is extremely challenging to use as a monitoring tool. LUS is operator-dependent, and it should be performed and interpreted by an experienced professional. Furthermore, LUS only evaluates pleural and subpleural changes, while deeper lesions could be missed since ultrasound waves cannot penetrate highly aerated lungs. Ultrasound findings also depend on the clinical characteristics of the patient; obesity and subcutaneous emphysema can interfere with passage of US waves and make the assessment more difficult. The measurement of compliance has been the object of intense study because normal or close-to-normal compliance has been hypothesized to benefit different respiratory supports in COVID-19 ARDS [22] . At the present time, compliance can be noninvasively measured by the Forced Oscillation Technique (FOT) parameter reactance. FOT is a noninvasive, non-expensive, and fast approach which measures lung function using sinusoidal pressure waves generated by a loudspeaker and forced into the lung during tidal breathing, requiring no effort maneuvers [52] . Furthermore, FOT is a simple approach to measure lung mechanics, since it needs the patient to have spontaneous tidal volume breathing for a maximum of 10 breath, and it uses a portable instrument. We showed in our preliminary abstract that it is feasible bedside in patients with critical COVID19 pneumonia [22] . A pressure-flow transducer measures inspiratory and expiratory flow and pressure, which are then separated from the breathing pattern by signal filtering. The fraction of pressure over flow at a specific frequency is called impedance (Z) and is measured in cmH 2 O·L −1 ·s −1 or kPa·L −1 ·s −1 [53] . The impedance of the respiratory system (Zrs) is the sum of the respiratory resistance (Rrs) and the respiratory reactance (Xrs) measured over a range of increasing frequencies (i.e., from 3 to 35 Hz) [52] . Reactance (Xrs) is the part of the impedance of the respiratory system (Zrs) related to the elastic properties of the lung periphery, and it is the sum of inertance (I, the force of the accelerating air column) and capacitance (C, related to the elastic properties of lung periphery). At low frequencies, the capacitive properties of the small peripheral airway predominate; on the contrary, inertance increases its contribution to reactance at higher frequencies. Therefore, reactance at 5 Hz (X 5 ) provides important information about distal airways. By convention, capacitance is defined negative, and inertance positive, and hence their sum is negative at low frequencies and positive at high frequencies. Conditions that reduce the elasticity of the lung, such as fibrosis and hyperinflation, make the capacitance increasingly negative, i.e., more negative X 5 values [52] . FOT has been applied to several clinical settings, as well as in lung function laboratories, with special regard to airway diseases and pediatric respiratory diseases [54, 55] , but it has also been used during CPAP and NIV [56] [57] [58] [59] . ARDS has been investigated by FOT in animal models and in the newborn. In an experimental model of lung recruitment/derecruitment, C x5 (oscillatory compliance derived from X 5 ) resulted in being highly specific in detecting the loss of ventilated lung [60] (Figure 4 ). Reactance has been suggested to have advantages over dynamic compliance (C dyn ), allowing for the conduction of studies to assess intra-tidal events (recruitments or over-distension) while maintaining the breathing pattern [60] . FOT has also been shown to allow the optimizing of PEEP, both in preterm infants, where surfactant deficiency is associated with increased probability of alveolar instability, atelectasis, and lung volume derecruitment [61] , and in the animal model [62] . The feasibility of FOT in severe COVID-19 pneumonia needing noninvasive support was recently studied at the Pulmonology Department of the University of Trieste (unpublished data), showing that it can provide useful additional pathophysiological parameters in patients with ARF undergoing high-flow nasal cannula (HFNC) oxygen support. Further studies are required to assess feasibility and reproducibility of this technique in the management of patients with ARF with impeding necessity of NIRS. [60] ). Cx5, 5Hz oscillatory compliance; VtissNA%, percentage of nonaerated tissue volume; CT, computed tomography; RM recruitment maneuvers. NIRS represents a possible first step in the management of COVID-19 patients [63] . Several observations reported that patients with COVID-19 phenotype 2 (or H), who are at higher risk of disease progression, could be in need of early intubation, while those who present with phenotype 1 (or L) can be initially managed with NIRS [12, 23, 24] . Indeed, COVID-19 patients receiving invasive mechanical ventilation showed a decrease in pulmonary volume and an increase in regions of poorly aerated or non-aerated lung tissue compared to those receiving NIRS [17] . Therefore, the invasive approach should be reserved to severe cases. The recognition of patients who are at higher risk of NIRS failure is challenging [63] , and the possible progression to patient self-inflicted lung injury (P-SILI) should take into account. This can be caused by several mechanisms including increased lung stress and strain, inhomogeneous distribution of ventilation, changes in lung perfusion, or patient-ventilator asynchronies [64] . Therefore, a strategy ranging from low to high-flow oxygen support, CPAP, or NIV and taking onto account invasive mechanical ventilation only in cases of failure of the previous NIRS strategies or phenotypes 2 or 3 is advisable ( Figure 5 ) [18] . Before considering intubation in patients who are at risk of NIRS failure, a trial period of awake prone positioning can be also carried out without delaying intubation if the oxygenation progressively worsens [18] . [60] ). C x5 , 5Hz oscillatory compliance; VtissNA%, percentage of non-aerated tissue volume; CT, computed tomography; RM recruitment maneuvers. NIRS represents a possible first step in the management of COVID-19 patients [63] . Several observations reported that patients with COVID-19 phenotype 2 (or H), who are at higher risk of disease progression, could be in need of early intubation, while those who present with phenotype 1 (or L) can be initially managed with NIRS [12, 23, 24] . Indeed, COVID-19 patients receiving invasive mechanical ventilation showed a decrease in pulmonary volume and an increase in regions of poorly aerated or non-aerated lung tissue compared to those receiving NIRS [17] . Therefore, the invasive approach should be reserved to severe cases. The recognition of patients who are at higher risk of NIRS failure is challenging [63] , and the possible progression to patient self-inflicted lung injury (P-SILI) should take into account. This can be caused by several mechanisms including increased lung stress and strain, inhomogeneous distribution of ventilation, changes in lung perfusion, or patient-ventilator asynchronies [64] . Therefore, a strategy ranging from low to high-flow oxygen support, CPAP, or NIV and taking onto account invasive mechanical ventilation only in cases of failure of the previous NIRS strategies or phenotypes 2 or 3 is advisable ( Figure 5 ) [18] . Before considering intubation in patients who are at risk of NIRS failure, a trial period of awake prone positioning can be also carried out without delaying intubation if the oxygenation progressively worsens [18] . When providing invasive mechanical ventilation in COVID-19, low tidal volumes (Vt) (4-6 mL/kg of predicted body weight [PBW]) with low plateau pressure (<28-30 cmH 2 O) and moderate levels of PEEP (10 to 15 cmH 2 O) should be applied [18] . In COVID-19 pneumonia with preserved lung compliance and few atelectasis areas, it is suggested to use low to moderate PEEP levels. On the contrary, in cases of low compliance phenotypes with extensive atelectasis, a strategy comprising moderate PEEP levels, prone positioning, and occasional recruiting maneuvers might be indicated [18] . Respiratory physiotherapy has also a key role in the management of the disease, yielding a potential for gas-exchange improvement [65, 66] . In summary, COVID-19 pneumonia is characterized by progressive increases in lung weight due to inflammatory edema affecting gas-exchange. In early phases, low V/Q areas are predominant with good response to higher oxygen fraction and moderate levels of PEEP, while in the later stages, true shunt is predominant with poor response to higher oxygen fractions and PEEP, not exceeding 15 cmH 2 O. The worsening of oxygenation during noninvasive respiratory support requires early intubation and initiation of invasive mechanical ventilation. When providing invasive mechanical ventilation in COVID-19, low tidal volumes (Vt) (4-6 mL/kg of predicted body weight [PBW]) with low plateau pressure (<28-30 cmH2O) and moderate levels of PEEP (10 to 15 cmH2O) should be applied [18] . In COVID-19 pneumonia with preserved lung compliance and few atelectasis areas, it is suggested to use low to moderate PEEP levels. On the contrary, in cases of low compliance phenotypes with extensive atelectasis, a strategy comprising moderate PEEP levels, prone positioning, and occasional recruiting maneuvers might be indicated [18] . Respiratory physiotherapy has also a key role in the management of the disease, yielding a potential for gas-exchange improvement [65, 66] . In summary, COVID-19 pneumonia is characterized by progressive increases in lung weight due to inflammatory edema affecting gas-exchange. In early phases, low V/Q areas are predominant with good response to higher oxygen fraction and moderate levels of PEEP, while in the later stages, true shunt is predominant with poor response to higher oxygen fractions and PEEP, not exceeding 15 cmH2O. The worsening of oxygenation during noninvasive respiratory support requires early intubation and initiation of invasive mechanical ventilation. HFNO, high-flow nasal oxygen; CPAP, continuous positive airway pressure; NIMV, non-invasive mechanical ventilation; IMV, invasive mechanical ventilation; V T , tidal volume; PBW, predicted body weight; PEEP, positive end-expiratory pressure; P, driving pressure; p-SILI, patient self-inflicted lung injury (patients on NIPPV who are generating massive negative pressures and high tidal volumes in the range of 10-12 cc/kg IBW); MAP, mean arterial pressure; HR, heart rate; ∆V A CO 2 , venous-arterial carbon dioxide tension difference; ScVO 2 , central venous oxygen saturation; US, ultrasound; CT, computed tomography; iNO, inhaled nitric oxide; ECCO2R, extracorporeal carbon dioxide removal; ECMO, extracorporeal membrane oxygenation; LMWH, low-molecular weight heparin; UFH, unfractioned heparin. Preserving spontaneous breathing in patients with ARF under non-invasive respiratory assistance may represent a risky gamble when hypoxemia is severe. On the one hand, several positive physiological effects have been described including the avoidance of deep sedation and/or myorelaxants drugs, the prevention of muscle mass loss, the sparing of diaphragmic function, and the reduction of delirium onset [67, 68] . However, a growing body of evidence derived from animal models and clinical investigations on classical ARDS has strengthened the hypothesis that the presence of intense respiratory effort producing excessive negative pleural pressure swings (P pl ) plays a critical role in the onset and progression of lung and diaphragm damage, especially when lung impairment is severe [69] [70] [71] [72] . This unfavorable mechanical condition predisposes patients to the so-called P-SILI, whose underlying mechanisms differentiate from those sustaining the well-known model of ventilatory induced lung injury (VILI). When lungs are healthy, the transpulmonary pressure (P L ) generated by diaphragmatic contraction is uniformly distributed over the entire lung surface. The elastic response of the lung follows a "liquid-like" behavior without local alveolar over-distention [73, 74] . When acute lung injury occurs, local inflammation and alveolar edema make lung tissue inhomogeneous. The transmission of the forces applied to pulmonary parenchyma during spontaneous breathing becomes asymmetrical, and the elastic response of the lung follows a "solid-like" behavior. In particular, the negative swing in pleural pressure generated during active inspiration is not uniformly distributed, being magnified in dependent regions and alongside the diaphragmatic interface, where high values of P L are concentrated [75] . The unbalanced application of physical forces during spontaneous breathing causes a pressure gradient between nondependent and dependent lung zones, resulting in a disproportionate distribution of tidal volume with an unsafe local stretch of the dependent lung (pendelluft phenomenon) [75] . A significant drop in intrathoracic pressure due to intense inspiratory effort can result in negative changes in alveolar pressure. The following increase in transmural vascular pressures in pulmonary capillaries predisposes one to the development of pulmonary edema [76] . Disparate radial traction forces, applied in the corner vessels adjacent to stress raisers, may generate a siphoning effect of blood towards areas of higher P L (pendelblut phenomenon) [77] . Load-induced diaphragm injury can occur during intense spontaneous breathing, as suggested by the radiological signs of muscle edema [72] and the histological evidence of fiber disruption, sarcomeric disturbance, and amplified inflammation [78] . These biophysical insults related to the magnitude of inspiratory effort and to the following lung parenchymal stretch, alveolar edema, and diaphragmatic overload can result in a pattern of progression from the initial lung damage, worsening ventilatory and clinical outcomes [70] . The characteristics of respiratory drive activation along with the mechanical and clinical consequence of spontaneous breathing in COVID-19 patients have become matters of investigation, giving the peculiar pathophysiological features of this unforeseen form of ARDS [79] . Since the onset of the pandemic, several clinical observations have pointed out that a considerable number of patients experiencing COVID-19 pneumonia in the early phase do not present subjective dyspnea despite severe hypoxemia, this condition being defined as "happy hypoxia" [80] [81] [82] . Although the mechanisms beyond the limited shortness of breath are not fully understood, it has been hypothesized that damage of the C-pulmonary afferent fibers driven by the inflammatory cascade or by direct viral involvement may affect the coupling between bio-mechanical stimuli and respiratory drive activation [83] . A recently published matched study comparing COVID-19 receiving non-invasive respiratory support with moderate to severe ARF with classical ARDS [84] showed a relatively low activation of respiratory drive in COVID-19 patients during the early phase (median change in esophageal pressure [∆P es ] 12.5 cmH 2 O, respiratory rate 28 bpm, Vte 9.2 mL/kg of PBW versus ∆P es 32 cmH 2 O, RR 35 bpm, expiratory tidal volume (Vte) 10.9 mL/kg of PBW), which is in line with the aforementioned concept of "happy hypoxia" [82] and underlines the mismatch between central drive activation and moderate to severe hypoxia, at variance with the typical form of ARDS. At least theoretically, these data seem to suggest that in the very early phase of assisted spontaneous breathing, the role of SILI in determining further lung damage is not as crucial in early COVID-19 ARDS as in typical forms of ARDS. In agreement with this, the dynamic compliance of the respiratory system was twice as high in COVID-19 patients as in those with traditional ARDS (55 vs. 25 mL/cmH 2 O) at comparable arterial partial pressures of oxygen/fraction of inspired oxygen (PaO 2 /FiO 2 ) ratios in the early stage of the disease. However, even if respiratory drive resulted in less stress as compared with ARDS, the application of NIV in these patients determined a significant reduction of inspiratory effort with values of ∆P es close to physiological ranges (6-10 cmH 2 O). Moreover, unpublished data on lung behavior during spontaneous breathing, according to different PEEP levels in this cohort, showed that elevated values of PEEP were inversely correlated with the relative change of the PaO 2 /FiO 2 ratio and dynamic lung compliance after NIV ( Figure 6 ). In contrast, typical ARDS patients showed a favorable association between PEEP values and gas exchange 2 h after starting NIV, suggesting a different behavior in response to recruitment. These findings are in line with those reported by Coppola et al., who showed that in 23 critically ill patients with COVID-19 pneumonia, increasing PEEP from a low (5 cmH 2 O) to a higher (15 cmH 2 O) level led to a significant deterioration in lung mechanics as assessed via esophageal manometry [85] . The concept of mechanical power has recently been developed to explore the interaction between ventilatory support and lung damage. In particular, the degree of VILI has been related to the amount of energy transferred from the mechanical ventilator to the respiratory system [86] . Assuming that the amount of energy to which the lung is subjected, even during assisted spontaneous breathing, may be crucial in P-SILI development, a simple surrogate of mechanical power can be derived by replacing the change in airway pressure during inspiration with dynamic transpulmonary pressure [87] . In patients with COVID-19, the baseline value of dynamic mechanical power was considerably lower than in ARDS (27 vs. 95 J/min, p < 0.0001). After a 2 h NIV trial, the dynamic mechanical power showed a significant increase in COVID-19 patients alone. This may suggest an unfavorable interaction between potential and kinetic energy transferred from the respiratory muscles and the mechanical ventilator to the lungs of these patients, at least in the early phase of the disease when respiratory drive is still preserved. In more advanced stages of COVID-19 pneumonia, following the phenotype transition with increase in lung weight and relative drop in lung compliance, an increase in respiratory drive has been documented and correlated with worsening of respiratory function during attempts to wean patients from mechanical ventilation [88] . A recent computational study has shown how in a model correlated to COVID-19 patients, when intense inspiratory effort (namely pleural pressure swing) was reached, the physical forces produced were comparable with those associated with VILI during mechanical ventilation [89] . The authors concluded that inspiratory effort in these patients should be carefully monitored and controlled to reduce the risk of lung injury. Given that esophageal pressure swings mirror P pl during spontaneous breathing, esophageal manometry by means of an esophageal balloon catheter is considered a reliable method to quantify the magnitude of inspiratory effort [90] . In typical ARDS, an intense inspiratory effort, as documented by high ∆P es swings, is associated with unfavorable ventilatory outcomes [70] . A pressure threshold to be considered harmful and predisposing to the onset of P-SILI in COVID-19 patients is still to be defined. However, the continuous monitoring of inspiratory effort through esophageal manometry may allow the impact of non-invasive respiratory support to be assessed and to improve the ventilatory management of spontaneously breathing patients with severe COVID-19. In particular, (1) the quantification of inspiratory effort may allow for a precise characterization of respiratory drive, whose hyperactivation require immediate intervention in order to reduce both lung tissue stress and the increase in pulmonary trans-vascular pressures sustained by vigorous breathing effort [89, 91] ; (2) the assessment of changes in ∆P es following the application of non-invasive respiratory support may help in early discriminating between good and low responders to respiratory assistance, avoiding the use of positive pressure when unneeded and intercepting non-responders to NIRS who may benefit of an upgrade to invasive mechanical ventilation ( Figure 7) ; (3) a continuous monitoring of respiratory effort may inform the changes in the respiratory mechanics of the patient; in particular, an abrupt increase in ∆P es may suggest a rapid disturbance of respiratory system compliance, mirroring the transition from a lung with fluid-like behavior to parenchymal solid-like elastic properties; (4) esophageal manometry could be useful to obtain information on lung mechanical features and the relative response to positive pressure application on the respiratory system. Indeed, a surrogate of lung compliance, namely dynamic compliance, can be derived comparing the values of P L with Vte. Furthermore, a simplified surrogate of mechanical power, defined as dynamic mechanical power, can be calculated as 0.098 * RR * Vte * (∆P L + PEEP) [87] . Although approximate, this index may represent a reliable estimate of the amount of energy transferred from respiratory muscle and ventilatory assistance to the lung during assisted spontaneous breathing. All these physiological variables may inform the clinician of lung recruitability at bedside, allowing for the optimization of PEEP during non-invasive respiratory assistance, while unfavorable changes in dynamic compliance and mechanical power may suggest limited lung recruitability and forecast the risk of local overdistension. Despite systematic assessment of inspiratory effort by means of esophageal monitoring being certainly appealing, this technique seems not easy to implement in everyday clinical practice [92] . This is partially due to technical issues such as the correct insertion and proper placement of the probe, which influences the accuracy and interpretation of measurements. Moreover, the procedure itself could be difficult when respiratory drive is markedly activated, as it may happen in awake patients with respiratory distress and severe gas exchange impairment [93] . Finally, the maneuver is invasive, and it may cause discomfort or potential side effects in awake patients with ARF [94] . disturbance of respiratory system compliance, mirroring the transition from a lung with fluid-like behavior to parenchymal solid-like elastic properties; (4) esophageal manometry could be useful to obtain information on lung mechanical features and the relative response to positive pressure application on the respiratory system. Indeed, a surrogate of lung compliance, namely dynamic compliance, can be derived comparing the values of PL with Vte. Furthermore, a simplified surrogate of mechanical power, defined as dynamic mechanical power, can be calculated as 0.098 * RR * Vte * (ΔPL + PEEP) [87] . Although approximate, this index may represent a reliable estimate of the amount of energy transferred from respiratory muscle and ventilatory assistance to the lung during assisted spontaneous breathing. All these physiological variables may inform the clinician of lung recruitability at bedside, allowing for the optimization of PEEP during noninvasive respiratory assistance, while unfavorable changes in dynamic compliance and mechanical power may suggest limited lung recruitability and forecast the risk of local overdistension. Despite systematic assessment of inspiratory effort by means of esophageal monitoring being certainly appealing, this technique seems not easy to implement in everyday clinical practice [92] . This is partially due to technical issues such as the correct insertion and proper placement of the probe, which influences the accuracy and interpretation of measurements. Moreover, the procedure itself could be difficult when respiratory drive is markedly activated, as it may happen in awake patients with respiratory distress and severe gas exchange impairment [93] . Finally, the maneuver is invasive, and it may cause discomfort or potential side effects in awake patients with ARF [94] . Practical flow-chart of respiratory assistance for patients with COVID-19 acute respiratory failure based on inspiratory effort assessment. Legend. HFNC trial might be started with close monitoring of inspiratory effort. If low values of ΔPes are detected, HFNC should be kept with close monitoring of esophageal pressure swings and gas exchange. In case of high inspiratory effort, noninvasive respiratory assistance should be upgraded to NIV. If ΔPes is reduced by positive pressure application, NIV might be continued with continuous monitoring of inspiratory effort. In case NIV fails to reduce inspiratory effort, a rapid switch to IMV should be considered. HFNO, high-flow nasal oxygen; NIV, non-invasive mechanical ventilation; MV, invasive mechanical ventilation; ΔPes, esophageal pressure. As we have established, severe COVID-19 presents different pathophysiological phases that partially resemble typical ARDS and have been categorized into three radiological patterns and clinical phenotypes (Table 1) . During the mildest forms or earlier phases of COVID-19 ARDS, the compliance of the respiratory system is not affected, but gas-exchange impairment mostly occurs due to an altered V/Q ratio. On the contrary, with the evolution of lung injury towards most severe or advanced forms, the decrease in aerated lung regions and the increase in non-aerated ones due to inflammatory edema lead to increased shunt. The clinical response to the application of external PEEP during mechanical ventilation depends on lung recruitability and compliance. Nevertheless, a growing body of evidence suggests that intense respiratory effort producing excessive negative pleural pressure swings (Ppl) plays a critical role in the onset and progression of lung and diaphragm damage in patients treated with NIV. The routine use of respiratory monitoring would be a powerful means to avoid the useless continuation of NIRS in patients who are at higher risk for respiratory deterioration and could benefit from early initiation of invasive mechanical ventilation. Forced Oscillation Techniques (FOTs) could help in identifying the subset of high-compliance patients who can benefit from NIRS Figure 7 . Practical flow-chart of respiratory assistance for patients with COVID-19 acute respiratory failure based on inspiratory effort assessment. Legend. HFNC trial might be started with close monitoring of inspiratory effort. If low values of ∆P es are detected, HFNC should be kept with close monitoring of esophageal pressure swings and gas exchange. In case of high inspiratory effort, noninvasive respiratory assistance should be upgraded to NIV. If ∆P es is reduced by positive pressure application, NIV might be continued with continuous monitoring of inspiratory effort. In case NIV fails to reduce inspiratory effort, a rapid switch to IMV should be considered. HFNO, high-flow nasal oxygen; NIV, non-invasive mechanical ventilation; MV, invasive mechanical ventilation; ∆P es , esophageal pressure. As we have established, severe COVID-19 presents different pathophysiological phases that partially resemble typical ARDS and have been categorized into three radiological patterns and clinical phenotypes (Table 1) . During the mildest forms or earlier phases of COVID-19 ARDS, the compliance of the respiratory system is not affected, but gas-exchange impairment mostly occurs due to an altered V/Q ratio. On the contrary, with the evolution of lung injury towards most severe or advanced forms, the decrease in aerated lung regions and the increase in non-aerated ones due to inflammatory edema lead to increased shunt. The clinical response to the application of external PEEP during mechanical ventilation depends on lung recruitability and compliance. Nevertheless, a growing body of evidence suggests that intense respiratory effort producing excessive negative pleural pressure swings (P pl ) plays a critical role in the onset and progression of lung and diaphragm damage in patients treated with NIV. The routine use of respiratory monitoring would be a powerful means to avoid the useless continuation of NIRS in patients who are at higher risk for respiratory deterioration and could benefit from early initiation of invasive mechanical ventilation. Forced Oscillation Techniques (FOTs) could help in identifying the subset of high-compliance patients who can benefit from NIRS continuation. Esophageal monitoring is an appealing technique for the systematic assessment of inspiratory effort, despite it implying technical issues that are difficult to overcome in everyday clinical practice. Advanced respiratory monitoring, including novel noninvasive inspiratory effort devices, could be useful to monitor patients with ARDS at risk for an injurious (spontaneous or assisted) ventilation, as may happen in the COVID-19 pandemic when the use of NIRS is extensive [6] . A more feasible method for measuring inspiratory effort without the technical issues of esophageal manometry could ameliorate P-SILI monitoring and help predict respiratory deterioration in the clinical setting. Further research is needed on noninvasive methods to quantify the magnitude of inspiratory effort to optimize the ventilatory management of patients with ARDS of different etiology, including COVID-19. COVID-19 ARDS is a new respiratory disease that arguably differs from traditional ARDS. For this reason, a personalized respiratory and monitoring strategy in patients with SARS-CoV-2 infection is paramount. An individualized ventilatory approach based on lung physiology, morphology, imaging, and identification of biological phenotypes may improve COVID-19 outcomes while individualizing mechanical ventilation practices. The authors declare no conflict of interest. WHO. WHO Coronavirus (COVID-19) Dashboard. 2021. Available online Duration of invasive mechanical ventilation prior to extracorporeal membrane oxygenation is not associated with survival in acute respiratory distress syndrome caused by coronavirus disease 2019 Extension of Collagen Deposition in COVID-19 Post Mortem Lung Samples and Computed Tomography Analysis Findings Interstitial Lung Disease at High Resolution CT after SARS-CoV-2-Related Acute Respiratory Distress Syndrome According to Pulmonary Segmental Anatomy Fifty Years of Research in ARDS. Gas Exchange in Acute Respiratory Distress Syndrome Gas exchange and ventilation-perfusion relationships in the lung Ventilation management and clinical outcomes in invasively ventilated patients with COVID-19 (PRoVENT-COVID): A national, multicentre, observational cohort study Pulmonary and extrapulmonary acute respiratory distress syndrome: Myth or reality? Pharmacological principles guiding prolonged glucocorticoid treatment in ARDS What Has Computed Tomography Taught Us about the Acute Respiratory Distress Syndrome? Vertical gradient of regional lung inflation in adult respiratory distress syndrome COVID-19 pneumonia: Different respiratory treatments for different phenotypes? Changes in lung composition and regional perfusion and tissue distribution in patients with ARDS Prolonged Low-Dose Methylprednisolone in Patients With Severe COVID-19 Pneumonia The History and Mystery of Alveolar Epithelial Type II Cells: Focus on Their Physiologic and Pathologic Role in Lung The role of chest CT in deciphering interstitial lung involvement: Systemic sclerosis versus COVID-19 Lung distribution of gas and blood volume in critically ill COVID-19 patients: A quantitative dual-energy computed tomography study Ten things you need to know about intensive care unit management of mechanically ventilated patients with COVID-19 Computed Tomography Assessment of Positive End-expiratory Pressure-induced Alveolar Recruitment in Patients with Acute Respiratory Distress Syndrome Computed tomography assessment of PEEP-induced alveolar recruitment in patients with severe COVID-19 pneumonia Distinct phenotypes require distinct respiratory management strategies in severe COVID-19 Monitoring lung mechanics by oscillometry in COVID 19 ARDS receiving non-invasive ventilation: A pilot study Spontaneous Breathing and Evolving Phenotypes of Lung Damage in Patients with COVID-19: Review of Current Evidence and Forecast of a New Scenario Identifying clinical and biochemical phenotypes in acute respiratory distress syndrome secondary to coronavirus disease-2019 Severity of lung involvement on chest X-rays in SARS-coronavirus-2 infected patients as a possible tool to predict clinical progression: An observational retrospective analysis of the relationship between radiological, clinical, and laboratory data COVID-19 outbreak in Italy: Experimental chest X-ray scoring system for quantifying and monitoring disease progression Altered pulmonary blood volume distribution as a biomarker for predicting outcomes in COVID-19 disease Well-aerated Lung on Admitting Chest CT to Predict Adverse Outcome in COVID-19 Pneumonia COVID-19 pneumonia imaging follow-up: When and how? A proposition from ESTI and ESR Potential links between COVID-19-associated pulmonary aspergillosis and bronchiectasis as detected by high resolution computed tomography Six-month Follow-up Chest CT Findings after Severe COVID-19 Pneumonia Post-Acute Sequelae of COVID-19 Pneumonia: Six-month Chest CT Follow-up Converging pathways in pulmonary fibrosis and COVID-19-The fibrotic link to disease severity Post-ARDS pulmonary fibrosis in patients with H1N1 pneumonia: Role of follow-up CT 6-month consequences of COVID-19 in patients discharged from hospital: A cohort study Comparative study of lung ultrasound and chest computed tomography scan in the assessment of severity of confirmed COVID-19 pneumonia Llamas-Fuentes, R. Correlation between Chest Computed Tomography and Lung Ultrasonography in Patients with Coronavirus Disease 2019 (COVID-19) Comparison Between Lung Ultrasound and Computed Tomographic Findings in Patients With COVID-19 Pneumonia Comparing lung ultrasound: Extensive versus short in COVID-19 (CLUES): A multicentre, observational study at the emergency department Significance of Lung Ultrasound in Patients with Suspected COVID-19 Infection at Hospital Admission. Diagnostics 2021, 11, 921 Lung ultrasound in COVID-19: Insights from the frontline and research experiences lung function and CT findings 3 months after hospital admission for COVID-19 Lung Ultrasound May Support Diagnosis and Monitoring of COVID-19 Pneumonia The Role of Imaging in COVID-19 Pneumonia Diagnosis and Management: Main Positions of the Experts, Key Imaging Features and Open Answers The emerging role of lung ultrasound in COVID-19 pneumonia Point-of-care lung ultrasound in three neonates with COVID-19 Lung Ultrasonography for the Diagnosis of SARS-CoV-2 Pneumonia in the Emergency Department The role of lung ultrasound as a frontline diagnostic tool in the era of COVID-19 outbreak The lung ultrasound: Facts or artifacts? In the era of COVID-19 outbreak A single-center comparative study of lung ultrasound versus chest computed tomography during the COVID-19 era Self-Performed Lung Ultrasound for Home Monitoring of a Patient Positive for Coronavirus Disease Measuring lung function using sound waves: Role of the forced oscillation technique and impulse oscillometry system Oscillation Mechanics of the Respiratory System: Applications to Lung Disease The safety and feasibility of the inhaled mannitol challenge test in young children Determinants of early-life lung function in African infants Noninvasive assessment of respiratory resistance in severe chronic respiratory patients with nasal CPAP Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP Airway and tissue mechanics in ventilated patients with pneumonia Telemonitoring in Chronic Obstructive Pulmonary Disease (CHROMED). A Randomized Clinical Trial Lung recruitment assessed by total respiratory system input reactance Forced oscillation technique for optimising PEEP in ventilated extremely preterm infants Optimisation of positive end-expiratory pressure by forced oscillation technique in a lavage model of acute lung injury Siempos, I.I. Effect of timing of intubation on clinical outcomes of critically ill patients with COVID-19: A systematic review and meta-analysis of non-randomized cohort studies Radiological-pathological signatures of patients with COVID-19-related pneumomediastinum: Is there a role for the Sonic hedgehog and Wnt5a pathways? An Experimental Pre-Post Study on the Efficacy of Respiratory Physiotherapy in Severe Critically III COVID-19 Patients Chest physiotherapy: An important adjuvant in critically ill mechanically ventilated patients with COVID-19 Long-Term Effects of Spontaneous Breathing During Ventilatory Support in Patients with Acute Lung Injury Mechanical Ventilation-induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes Acute respiratory failure following pharmacologically induced hyperventilation: An experimental animal study Early Inspiratory Effort Assessment by Esophageal Manometry Predicts Noninvasive Ventilation Outcome in De Novo Respiratory Failure. A Pilot Study Mechanical Ventilation to Minimize Progression of Lung Injury in Acute Respiratory Failure Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort Continuous recording of pleural surface pressure at various sites Ipsilateral transpulmonary pressures during unilateral electrophrenic respiration The Comparison of Spontaneous Breathing and Muscle Paralysis in Two Different Severities of Experimental Lung Injury* Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort Bench-to-bedside review: Microvascular and airspace linkage in ventilator-induced lung injury Diaphragm Muscle Fiber Weakness and Ubiquitin-Proteasome Activation in Critically Ill Patients Respiratory Monitoring at Bedside in COVID-19 Patients Critical care crisis and some recommendations during the COVID-19 epidemic in China Clinical Characteristics of Coronavirus Disease 2019 in China The pathophysiology of 'happy' hypoxemia in COVID-19 Lack of dyspnea in patients with COVID-19: Another neurological conundrum? Inspiratory Effort and Lung Mechanics in Spontaneously Breathing Patients with Acute Respiratory Failure due to COVID-19: A Matched Control Study Oesophageal manometry and gas exchange in patients with COVID-19 acute respiratory distress syndrome Power to mechanical power to minimize ventilator-induced lung injury? Calculation of mechanical power for pressure-controlled ventilation High Respiratory Drive and Excessive Respiratory Efforts Predict Relapse of Respiratory Failure in Critically Ill Patients with COVID-19 High risk of patient self-inflicted lung injury in COVID-19 with frequently encountered spontaneous breathing patterns: A computational modelling study Esophageal pressure monitoring Management of COVID-19 Respiratory Distress The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure Technical aspects of bedside respiratory monitoring of transpulmonary pressure Perception of esophageal manometry