key: cord-0842144-t0umug55 authors: Sanguinetti, Angela; Outcault, Sarah; Pistochini, Theresa; Hoffacker, Madison title: Understanding teachers' experiences of ventilation in California K‐12 classrooms and implications for supporting safe operation of schools in the wake of the COVID‐19 pandemic date: 2022-02-15 journal: Indoor Air DOI: 10.1111/ina.12998 sha: 3f51fd3f18658874a6f627a633c4f5879e4987b5 doc_id: 842144 cord_uid: t0umug55 Classrooms are often under‐ventilated, posing risks for airborne disease transmission as schools have reopened amidst the COVID‐19 pandemic. While technical solutions to ensure adequate air exchange are crucial, this research focuses on teachers’ perceptions and practices that may also have important implications for achieving a safe classroom environment. We report on a (pre‐pandemic) survey of 84 teachers across 11 California schools, exploring their perceptions of environmental quality in relation to monitored indoor environmental quality (IEQ) data from their classrooms. Teachers were not educated regarding mechanical ventilation. Errors in HVAC system installation and programming contributed to misunderstandings (because mechanical ventilation was often not performing as it should) and even occasionally made it possible for teachers to turn off the HVAC fan (to reduce noise). Teachers did not accurately perceive (in)sufficient ventilation; in fact, those in classrooms with poorer ventilation were more satisfied with IEQ, likely due to more temperature fluctuations when ventilation rates were higher combined with occupants’ tendency to conflate perceptions of air quality and temperature. We conclude that classroom CO(2) monitoring and teacher education are vital to ensure that teachers feel safe in the classroom and empowered to protect the health of themselves and their students. been demonstrated to negatively affect student health and learning. 1, 7, 10, 11, 12, 13, 14, 15, 16, 17 For example, Chatzidiakou et al. 1 found that VRs lower than 8 L/s per person were associated with a higher risk of viral infections and asthma symptoms, as well as diminished concentration and attention span. The COVID-19 pandemic raises additional concerns because sufficient ventilation is crucial to reduce risks of airborne disease transmission, particularly in densely occupied indoor spaces like classrooms. 18 , 19 Dai and Zhao 20 suggest that reducing transmission risk to 1% in a classroom would require a minimum VR of about 706 cfm (333 L/s) per infector for 3 h of exposure, or about 177 cfm (84 L/s) if masks are worn. Hou et al. 19 identified 500 ppm as the CO 2 threshold associated with sufficient outdoor ventilation to prevent classroom COVID-19 aerosol spreading. ASHRAE has no requirement to maintain CO 2 levels below a specified concentration, but Chan et al. 8 estimate that a classroom ventilated at 7 L/s-person (per ASHRAE 62.1 standard) would have a steady-state CO 2 concentration of 1100 ppm. However, increased ventilation rates have drawbacks including increased exposure to outdoor pollutants as well as potential issues with thermal comfort and energy consumption associated with increased conditioning for heating and cooling outdoor air. Increased ventilation rates can be combined with improved filtration of recirculated air to reduce the probability of long-range airborne infectious disease transmission. 21 This paper assesses ventilation systems that were designed to meet California's outdoor air rate code requirement for classrooms of 7 L/s-person, which slightly exceeds ASHRAE standard 62.1 under typical classroom occupancy conditions. It is very important to meet, at minimum, this requirement in the midst of the COVID-19 pandemic. As schools reopen amidst the pandemic, it is vitally important that classrooms are adequately ventilated to protect the health of students and teachers. It may also be critical to educate teachers about classroom ventilation to instill confidence and support behaviors that complement and do not counteract planned building performance. This research draws on IEQ monitoring and teacher survey data from a study conducted during the 2016-2017 school year of California classrooms to explore teachers' experiences with classroom heating, ventilation, and air conditioning (HVAC) systems. The study highlights potential non-technical challenges that may arise from or inhibit technical solutions to improve ventilation such as teachers' use of fan controls and supplementary ventilation strategies. The California Energy Commission funded the University of California, Davis, to lead a research project (contract EPC- [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] that included an HVAC characterization study of 11 schools across the state that had recently replaced single-zone HVAC systems (where single zone refers to one HVAC system per classroom). The study included on-site technical audits, IEQ monitoring, a teacher survey, and interviews with school district facilities staff. This paper reports data from the teacher survey and IEQ monitoring, both of which focused on 104 classrooms across the 11 schools. For full results and detailed technical assessment of HVAC system performance and IEQ, see Pistochini et al. 22 and Chan et al. 8 . The HVAC characterization study found that the new equipment largely failed to deliver code-compliant levels of ventilation (7 L/sperson) for a host of reasons, mainly resulting from a lack of testing, inappropriately adjusting outdoor air rates at the time of installation, and problems with operation and maintenance. Nearly 70% of the classrooms had a mean daily maximum 15-min average CO 2 concentration exceeding 1100 ppm (commensurate with ASHRAE 62.1, per. 8 Estimated ventilation rates across classrooms had a mean of 5.2 L/s-person (SD = 2.0 L/s-person). Also worth noting, about 60% of the monitored classrooms had mean temperatures higher than 23℃ (73.4℉). Student performance research suggests classroom temperatures lower than 22-23℃ are optimal. 11,17 Twenty-two percent of classrooms were warmer than 78℉ for more than 20% of school hours. • Given the importance of classroom IEQ, ventilation systems need to be programmed to operate fans continuously during occupied hours to ensure delivery of adequate ventilation air. • Occupant control limitations and the role of mechanical ventilation need to be explained to teachers so that the importance of the HVAC fan is understood. • HVAC noise mitigation strategies (e.g., acoustic absorption materials or a microphone system for the teacher) may be necessary to minimize disruption to the learning environment while maintaining healthy IEQ. issues that may improve ventilation or inadvertently worsen it? The answer will have implications for teacher training, allowable/recommended practices, and technical strategies. Literature on whether building occupants can reliably perceive under-ventilation is inconclusive. Some studies that compare teacher and student IEQ perceptions with measured VRs (typically estimated from CO 2 measurements) suggest that they cannot reliably perceive under-ventilation. [23] [24] [25] [26] [27] Others have found relationships between lower ventilation and/or higher CO 2 concentrations and teacher and/ or student perceptions of poorer air quality in general, 17,28 worse air freshness, 17, 29 greater odor strength 25, 29 or stuffiness. 16 Kinshella et al. 30 also found there were more complaints about dryness and dustiness in classrooms where CO 2 levels exceeded 1000 ppm for more than 10% of the day. Dorizas et al. 31 were unique in identifying a counterintuitive relationship between higher CO 2 and greater satisfaction with indoor air quality, despite also identifying a negative relationship between CO 2 and student health and performance. Indoor temperature seemed to be a strong factor influencing satisfaction with air quality: Students in the coolest rooms (median temperature of 22.3°C) were "totally satisfied" with the air quality whereas those in rooms about 25°C, were "totally dissatisfied." The authors hypothesized that indoor temperature may have been a confounding variable in the observed relationship between CO 2 and air quality satisfaction since greater ventilation may have raised indoor temperatures (in cooling season). Similarly, Norbäck and Nordström 28 found that maintaining temperatures below 22°C was the dominant factor in teachers' satisfaction with indoor air quality. Other variables that may lead students and teachers to perceive poor air quality include higher relative humidity, 31 higher levels of VOCs, molds, bacteria, and respirable dust; or when buildings do not use a mechanical air supply. 27 The present study considered teachers' perceptions and practices related to all of the above IEQ parameters that have been found to be related to ventilation and perceived air quality. The HVAC characterization study focused on public schools that had within the last three years replaced at least five, single-zone classroom HVAC replacements. Those with more replaced units were prioritized to increase classroom sample size. For inclusion in the study, classrooms had to be typical rather than special-use (such as art or chemistry labs that may exhibit atypical IEQ conditions). Data from schools' applications to a California state-funded energy efficiency program (California Clean Energy Jobs Act, Proposition 39, 2013-2017) were used to identify schools (and classrooms) that fit these criteria. In addition, the research team utilized its professional network to identify other qualified schools, including those that did not use the program but had installed HVAC replacements. The research team targeted certain districts to achieve a sample that reflects some of the range of California schools' characteristics, in terms of district size, population density, region, and average household income. Ultimately, 104 classrooms from 11 schools (6 to 10 classrooms per school) in 9 public school districts were enrolled. Classroom served Kindergarten through 12th grades. Of the 104 classrooms, 68% were permanent construction and 32% were portables, which is also representative of California's K-12 classrooms † . In each of the studied classrooms, the research team installed a wallmounted, laboratory-calibrated, CO 2 sensor (Vaisala, Finland) to measure CO 2 concentrations by infrared absorption. The CO 2 sensor was installed at a location away from doors, windows, and supply air outlets to reflect typical room conditions more accurately. Data loss (e.g., power unplug and bad sensor connection) from 10 classrooms reduced the sample size for CO 2 monitoring to 94 classrooms. During field visits to install monitoring equipment, researchers left a letter on the teacher's desk in each of the 104 classrooms to inform them about the installed equipment and notify them to expect an email about the teacher survey. Seven classrooms were shared by two teachers, both of whom were recruited, for a total of 111 recruited teachers (only the first response for these classrooms was retained to meet the independent observations criterion for statistical tests performed). Teachers' email addresses were collected from school administrators and staff or school websites. Emails were sent to teachers on a rolling basis (one school at a time) from October 2016 to June 2017 as the equipment installation was completed. The email provided an informed consent document and invitation to participate in a 15-min survey regarding teachers' experience with heating, cooling, and ventilation in their classrooms. As an incentive to participate, each teacher was offered a $25 Target Gift Card, delivered via email upon completion of the survey. Up to three weekly reminders following the initial invitation were sent to teachers to request their participation if they had not yet completed the survey. The survey could be completed in multiple sessions rather than all at once. After removing responses from any classrooms represented twice as well as those less than 50% complete, the final sample was 84 teachers. The sample size for individual questions was at times lower than 84 because respondents were able to skip questions, and the module on classroom heating was skipped for teachers who had not yet experienced a heating season in their classroom with the newly installed HVAC equipment. The online survey programmed in Qualtrics included primarily closed-ended questions with Likert-style response options, as well as some open-ended questions to elicit more detailed explanations. Questions pertained to teachers' perceptions and practices related to ventilation and IEQ more broadly, since ventilation interacts with other parameters and occupant perceptions of ventilation may be conflated with these other parameters (e.g., temperature, relative humidity, and odor). IEQ perception questions included overall satisfaction with air quality and overall satisfaction with temperature (response options: Very dissatisfied, Dissatisfied, Neutral, Satisfied, and Very satisfied); the degree to which air quality or temperature interferes with the learning environment (Doesn't interfere, Interferes a little, and Interferes a lot); and frequency of specific air quality issues: stuffy or stale, drafty, smelly, dusty or dirty, too dry, and too humid (Never, Less than once a month, About once a month, Several times a month, About once a week, Several times a week, and On a daily basis). Questions about ventilationrelated practices included how often teachers use the HVAC system, box or floor fans, windows, and doors to circulate or freshen the air in their classroom (Never, Less than once a month, About once a month, Several times a month, About once a week, Several times a week, and On a daily basis); and whether they make efforts to circulate or freshen the air more or less than they would like to (with prompts to explain further). All IEQ perceptions and ventilation-related practices questions were asked separately for heating and cooling seasons. Several questions were asked just once, independent of season. These included perception of whether classrooms received enough fresh air from the HVAC system alone (Yes or No, with an openended comment box and prompt to explain "No" responses); and whether teachers use the HVAC system, fans, doors, or windows for reasons other than to heat, cool, circulate, or freshen the air. Teachers were also asked about the level of noise the HVAC system makes (Quiet, Somewhat noisy, and Very noisy); whether the noise impacts the learning environment (Interferes, Enhances by drowning out distractions, Neither interferes nor enhances), with a follow-up open-ended question to explain further if an impact was indicated; and how often they turn off the HVAC system because of the noise. The eleven schools in the study are located across 9 counties in California and 6 of its 16 climate zones (CZ), as Table 1 illustrates. All classrooms were designed to be conditioned and mechanically ventilated by a single-zone packaged HVAC system, an inclusion criterion of the study. Schools 3-6 were monitored during heating season, whereas all others were monitored during cooling and shoulder seasons (heating and/or cooling mode operation was determined based on supply air temperature). Schools 1 and 8-11 were cooling- Classrooms were occupied from 4 to "more than 10" hours per day, with a mode of 8 h. Results are organized in six sections. We first report teachers' overall assessments of their classroom IEQ, in terms of general satisfaction with air quality and temperature as well as prevalence of specific air quality complaints. We then describe their perceptions of In the survey, teachers were asked a series of questions about their perceptions of temperature in cooling and heating seasons, and then another series of questions about their perceptions of air quality during cooling and heating seasons. When rating their satisfaction with classroom temperature and air quality, although more teachers were satisfied than not (Figures 1 and 2) , a notable minority reported that each interfered with the learning environment to some degree ( Figures 3 and 4 ). Teachers' satisfaction levels with temperature and air quality were highly correlated ( Table 2) . Most teachers reported one or more frequent air quality issue (Table 3) , "stuffy or stale" air being the most common. Open-ended responses revealed more details about temperature and air quality issues, including speculation on potential causes. One theme was the uneven distribution of space conditioning (i.e., poor "mixing") contributing to thermal discomfort, as the following The ASHRAE guidelines on mechanical ventilation are designed to ensure that HVAC systems provide adequate ventilation to classroom occupants without the need for supplemental strategies. However, survey data also revealed that teachers seem to have some misperceptions about how mechanical ventilation works (or is intended to work). This is perhaps unsurprising given the general inadequate ventilation in these classrooms. For example, a common perception was that the HVAC system did not deliver fresh air at all, for example: We have no access to fresh air in our classrooms. The fan blows the air within the classroom. The air in the room when the HVAC fan alone is used is not fresh, but is humid and stuffy. Another perception was that ventilation was only occurring when the air conditioner was on, for example: The system would need to be operating in cooling mode at most times to circulate enough fresh air. Relationships between teacher perceptions of IEQ and monitored person (L/s-person), C15max is the daily maximum 15-min average classroom CO 2 concentration (ppm), and C 0 is the outdoor CO 2 concentration (ppm), assumed to be 400 ppm. For the most part, teacher satisfaction with overall air quality did not correlate with ventilation (Table 4 ). However, ventilation did correlate strongly (and negatively) with satisfaction with classroom temperature. In summary, teachers in classrooms with better ventilation were less comfortable with classroom temperatures. For example, Figure 5 illustrates a clear, negative relationship between mean VR and satisfaction with temperature. Classrooms where teachers were "very dissatisfied" with the temperature had a 42%-58% higher mean VR than classrooms where teachers reported being "very satisfied." Independent t-tests comparing ventilation measures with whether or not teachers reported frequent specific air quality concerns (i.e., a few times per week or on a daily basis) yielded only a few significant findings out of 84 possible relationships (six air quality complaints for each of two seasons, combined with seven VR and CO 2 measures). Classrooms where teachers reported frequent issues with "stuffy or stale" or "too humid" air in the cooling season had lower peak CO 2 levels than classrooms where teachers did not report frequent issues [often stuffy: Counterintuitively, classrooms where teachers reported getting enough fresh air from the HVAC system alone had worse ventilation than those where teachers did not perceive sufficient fresh air from HVAC alone ( Figure 6 ). This trend is notable because One explanation for this relationship could be that teachers who did not perceive sufficient fresh air from HVAC alone may be more likely to open doors and windows, which is explored in the following section. When asked about non-HVAC strategies they use to improve classroom ventilation, teachers most commonly reported opening exterior doors (Table 5 ). However, many teachers also noted concerns that kept them from opening doors, including student safety, energy waste, noise or other nuisances coming into the classroom, In order to provide a safe school, I would rather not resort to opening the doors to refresh the air. windows did so less often than they would like because it introduced other nuisances when they opened them (e.g., bugs flying inside and noise) and concern for wasting energy if they could not turn off heating and cooling. Since quite a few teachers reported frequently opening their ex- Most classroom thermostats (85%) allowed for some temperature control, typically allowing the teacher to adjust the set point within a We need more training with this. I have no idea how to run the fan in the classroom. Perhaps I'm not aware of all the options (how to turn on the fan). While most teachers had some control over the temperature settings in their classrooms (within an approved range), the majority did not have any control over the HVAC fan in their classrooms. This is common in classrooms and is intended to ensure the fan operates continuously during occupied hours in order to achieve code-required VRs. Only 7 teachers' thermostats offered them direct control of F I G U R E 6 CO 2 levels in relation to teachers' perception of whether or not their HVAC system provides their classroom with sufficient fresh air TA B L E 5 Percentage of teachers who use each ventilation strategy frequently (i.e., several times/week or on daily basis) Exterior door 51% 27% Interior door 20% 19% Window(s) 13% 9% Box or standing fan 13% 4% Any of the above 55% 43% the fan, independent from the temperature settings. In 20 teachers' rooms, including 5 of the 7 where teachers had direct fan control, the thermostat was programmed to Auto, which means the fan only automatically runs when the air conditioner or heater runs, rather than continuously, as intended. Teachers in the 15 rooms with HVAC on Auto (but no direct fan control) were theoretically able to adjust the temperature to get the fan to come on or turn off if they had some control over the temperature (which all but one did); however, this was problematic, for example, We are locked out of the fan control, so we can't turn that on without changing the temperature of the room. Sometimes we don't need to change the temperature of the classroom, and that is when we don't get enough fresh air, usually. [Mean VR: 2.9 l per sec per person] To capture teachers' use of fan control when available, respondents were asked, "How often do you adjust (or activate) the HVAC system (or its fan) in order to circulate or freshen the air in your classroom?" During the cooling and heating season, 43% and 38%, respectively, said they adjust the HVAC system at least several times per week for these purposes. Note that these percentages exceed the portion of teachers who actually had the ability to control the HVAC fan either directly or indirectly by turning on the AC or heater (26%). This is consistent with the perception of some teachers that the HVAC system only brings in fresh air when the air conditioning is on. Of paramount importance is improving the effectiveness of classroom ventilation systems so that they do indeed protect staff and students by mitigating the risk of infectious disease transmission. HVAC system noise also needs to be addressed as many teachers in this study reported that the HVAC noise was detrimental to learning and the overall classroom experience. While students and teachers are wearing masks in classrooms, the noise problem may be compounded. New acoustic strategies, such as a microphone for the teacher, may be warranted even if engineers can devise quieter systems. Some teachers were frustrated that they could not control the HVAC fan (e.g., turn it off due to noise), and teachers who had some control of their temperature set points were more satisfied with classroom temperature than those without control. Allowing all teachers some control over their thermostat set point and increasing the range of the allowable set point is likely to improve comfort and satisfaction. It is well-documented that perceived control over environmental conditions leads to increased satisfaction. 33 For the most part, teachers did not seem to accurately perceive mechanical ventilation sufficiency. Although the majority did report a lack of sufficient ventilation from HVAC alone, which was in fact quite common, there was generally a lack of correlation between measured ventilation and teachers' satisfaction with classroom air quality, and no compelling evidence of relationships between poor ventilation and specific air quality complaints. Moreover, those who perceived adequate ventilation from their classroom HVAC system, though more satisfied with both air quality and temperature, actually had worse classroom ventilation. Many teachers, particularly those who were not satisfied with HVAC system ventilation, frequently opened their exterior classroom door to improve ventilation. There was some evidence that those who engaged in this practice had better classroom ventilation, but they were less satisfied with air quality than those who did not open their door frequently. Chan et al. 8 found no relationship between door state (per sensor data rather than teacher report) and ventilation. However, the door sensor data can be imprecise (e.g., a door left ajar 1 inch will register as open), so it may be that teacher report in this case is more accurate than monitored data. This study also provides some evidence that air quality and temperature can be conflated in occupant perceptions of IEQ. Teachers' satisfaction with air quality and temperature were highly correlated, and teachers were more often "neutral" in assessing air quality, suggesting less confidence. This may actually contribute to inaccurate perceptions of air quality based on thermal comfort (i.e., if thermal comfort is low, occupants may perceive poor air quality, and if thermal comfort is high, they may be inclined to think air quality is good). Moreover, study findings point to a potential phenomenon whereby the mechanics of HVAC ventilation could actually be responsible for a negative relationship between ventilation and thermal comfort. Teachers in classrooms with worse ventilation were more satisfied with classroom temperature, consistent with Dorizas et al. 31 . When the supply fan for the HVAC system is running continuously as designed to provide ventilation, outdoor air (cold in winter and hot in summer) is continuously supplied to the space as a fraction of the supply air. In a classroom that is adequately ventilated, the outdoor air fraction is approximately 30%-50%. The heating or cooling then cycles on and off to meet the room temperature set point. When the heating and cooling are off, the supply air temperature may be uncomfortable in a classroom with adequate ventilation, blowing air colder than the room temperature in winter and warmer than the room temperature in summer. Occupants near the vents are exposed to temperature swings and drafts, which may adversely affect their thermal comfort. Increasing ventilation rates also increases the required heating and cooling, meaning that the cooling or heating cycles per hour increase, which also may adversely affect the comfort of those near vents. This explanation is supported by comments from participants about the discomfort of students near vents. The variation in supply air temperatures resulting from fluctuating outside air temperatures and compressor cycling could be improved with engineering solutions, such as variable speed compressor technology that can modulate the amount of heating and cooling provided and continuously provide consistent supply air temperatures. These findings suggest that some teachers may perceive that air quality has worsened when they return to classrooms where ventilation has actually been improved to combat COVID-19 transmission. This again points to the importance of CO 2 monitoring and teacher training on HVAC systems. Future research should rigorously model the relationships between IEQ perceptions and VRs, including to better understand the potential for conflation of temperature and air quality in occupants' IEQ perceptions. It would also be useful to replicate this research to determine whether and how teachers' knowledge and attitudes regarding ventilation have changed as a result of the pandemic. This research suggests that technical solutions for improved ventilation in schools, although absolutely critical may not be sufficient to support teachers' confidence in the safety of their classrooms in the midst of the COVID-19 pandemic. Improved ventilation will not automatically be perceived as such, and in some cases teachers may feel their classroom air quality has worsened given the tendency to conflate temperature and air quality. HVAC system noise, already a major problem in many classrooms, will be even more detrimental when combined with mask wearing. When designing more effective ventilation systems, noise reduction should be a priority. Schools should also consider audio supports and practices to ensure students and teachers can hear each other and get sufficient breaks from noise. Classroom CO 2 monitoring and teacher training on how mechanical ventilation systems work are vital to ensure that teachers feel safe returning to the classroom during the pandemic and empowered to protect the health of themselves and their students. The authors thank Wanyu R. Chan for leading the indoor air quality monitoring study, part of the broader research project, data from which were leveraged in our analyses in this paper. We are also grateful to the teachers who participated in this research to provide their valuable perspectives on classroom air quality. The authors have no conflicts of interest to declare. The peer review history for this article is available at https://publo ns.com/publo n/10.1111/ina.12998. The data that support the findings of this study are available from the corresponding author upon reasonable request. What do we know about indoor air quality in school classrooms? A critical review of the literature Indoor air quality in innercity schools and its associations with building characteristics and environmental factors Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Ventilation for Acceptable Indoor Air Quality Building Energy Efficiency Standards for Residential and Nonresidential Buildings Ventilation rates in recently constructed US school classrooms The ventilation problem in schools: Literature review Ventilation rates in California classrooms: why many recent HVAC retrofits are not delivering sufficient ventilation Association of classroom ventilation with reduced illness absence: a prospective study in California elementary schools Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information Association between substandard classroom ventilation rates and students' academic achievement Effects of classroom ventilation rate and temperature on students' test scores A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study Associations between Classroom CO 2 Concentrations and Student Attendance in Washington and Ventilation rates and health: multidisciplinary review of the scientific literature Indoor environmental quality in school buildings, and the health and wellbeing of students The effects of outdoor air supply rate and supply air filter condition in classrooms on the performance of schoolwork by children (RP-1257) Numerical investigation of aerosol transport in a classroom with relevance to COVID-19 Bayesian calibration of using CO 2 sensors to assess ventilation conditions and associated COVID-19 airborne aerosol transmission risk in schools. medRxiv Association of infected probability of COVID-19 with ventilation rates in confined spaces: a Wells-Riley equation based investigation HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs Improving ventilation and indoor environmental quality in California K-12 schools Ventilation rates in schools and pupils' performance Indoor environmental quality and pupil perception in Italian primary schools Subjective indoor air quality in schools-the influence of high room temperature, carpeting, fleecy wall materials and volatile organic compounds (VOC) The effect of increased classroom ventilation rate indicated by reduced CO 2 concentration on the performance of schoolwork by children Subjective indoor air quality in schools in relation to exposure An experimental study on effects of increased ventilation flow on students' perception of indoor environment in computer classrooms An experimental investigation of the indoor air quality in fifteen school buildings in Perceptions of indoor air quality associated with ventilation system types in elementary schools A holistic approach for the assessment of the indoor environmental quality, student productivity, and energy consumption in primary schools Teacher supply in California: A report to the Legislature On the behaviour and adaptation of office occupants Thermal comfort and use of thermostats in Finnish homes and offices Assessing building performance in use 4: the Probe occupant surveys and their implications Adaptive thermal comfort and sustainable thermal standards for buildings Forty years of Fanger's model of thermal comfort: comfort for all? Indoor Air Understanding teachers' experiences of ventilation in California K-12 classrooms and implications for supporting safe operation of schools in the wake of the COVID-19 pandemic