key: cord-0841984-l9pitb3y authors: Firle, Carl; Steinmetz, Anke; Stier, Oliver; Stengel, Dirk; Ekkernkamp, Axel title: Aerosol emission from playing wind instruments and related COVID-19 infection risk during music performance date: 2022-05-21 journal: Sci Rep DOI: 10.1038/s41598-022-12529-2 sha: 278948fc749b83a35237af3d40cf4a8aa355da21 doc_id: 841984 cord_uid: l9pitb3y The pandemic of COVID-19 led to restrictions in all kinds of music activities. Airborne transmission of SARS-CoV-2 requires risk assessment of wind instrument playing in various situations. Previous studies focused on short-range transmission, whereas long-range transmission risk has not been assessed. The latter requires knowledge of aerosol emission rates from wind instrument playing. We measured aerosol concentrations in a hermetically closed chamber of 20 m(3) in an operating theatre as resulting from 20 min standardized wind instrument playing (19 flute, 11 oboe, 1 clarinet, 1 trumpet players). We calculated aerosol emission rates showing uniform distribution for both instrument groups. Aerosol emission from wind instrument playing ranged from 11 ± 288 particles/second (P/s) up to 2535 ± 195 P/s, expectation value ± uncertainty standard deviation. The analysis of aerosol particle size distributions shows that 70–80% of emitted particles had a size of 0.25–0.8 µm and thus are alveolar. Masking the bell with a surgical mask did not reduce aerosol emission. Aerosol emission rates were higher from wind instrument playing than from speaking or breathing. Differences between instrumental groups could not be found but high interindividual variance, as expressed by uniform distribution of aerosol emission rates. Our findings indicate that aerosol emission depends on physiological factors and playing techniques rather than on the type of instrument, in contrast to some previous studies. Based on our results, we present transmission risk calculations for long-range transmission of COVID-19 for three typical woodwind playing situations. Woodwind instrument playing by an infectious person imposes disease transmission risk on other persons in the same room at two different scales of distance: short-range and long-range. Short range transmission refers to transmission occurring close to the source of aerosol, where there is still a directional respiratory jet and concentrations will be higher because little diffusion has occurred. Long range transmission refers to transmission occurring after this respiratory jet has dissipated and the aerosol is homogeneously dispersed throughout the environment. The primary aerosol cloud in immediate vicinity of the player may carry pathogens in amounts sufficient to provoke quick infection of a susceptible person nearby. Within this nearfield of a spreader disease transmission occurs in a discontinuous manner difficult to predict 14 and dependent on both distance and contact time. Within the short range, large droplets with limited reach convey high amounts of virus and it is a matter of coincidence whether they are inhaled or not. Susceptible persons in this region are subject to what we call short-range exposure to infection risk. While larger droplets (aerodynamic diameters ≥ 30 µm) soon deposit due to gravitational sedimentation or shrink to aerosol particles suspensible in air 15 , fine aerosol particles (with equilibrium diameters ≤ 5 µm) stay airborne for long time and spread evenly in the surrounding air 16, 17 . In absence of technical measures, such as capture-type ventilation hoods, aerosols will accumulate in the room air at largely homogeneous concentrations. When infectious, they produce a base level of infection risk which increases over time and does not depend on a susceptible person's position in the room 1, 5 . Susceptible persons are subject to what we call long-range exposure to infection risk 1, 5 . Long range transmission is sensitive to the specific details of the environment. Long-range transmission probability calculation requires knowledge of aerosol particle emission rates along with exposure time, fresh air flow rate, room space volume, pulmonary ventilation rate, number of occupants, and the critical dose of infection 18, 19 . Previous studies of aerosol emission during woodwind playing gained important insight on the structure and extension of the respiratory jet and the nearfield cloud and helped to specify distancing rules for avoidance of short-range exposure. The flow structures in the vicinity of woodwind players have been investigated to characterize the shape, extensions and particle size composition of the primary exhalation cloud [20] [21] [22] [23] . The local air concentration of aerosol has been found to decay to background level on a sub-meter length scale which indicates efficient aerosol dilution in the ambient air 22 . The plume generated by playing the clarinet has been found to be highly directional, to have high velocity, and to disperse quickly 24 . No air motion could be measured in 2 m distance in front of woodwinds which was the largest reach of aerosol clouds observed 20, 21 . A reduction of aerosol emission by 50% (for particles in the size range 0.5-14 µm) to 79% (0.3-5 µm) when using a mask around the bell has been found 22, 25 . He et al. have assessed aerosol emission using aerodynamic particle sizers (APS) directly under the outlet of wind instruments to characterize the aerosol generation of different woodwind and brass instruments 26 . Their results showed that playing wind instruments, in general, generates a higher number of aerosol particles than breathing and speaking. The amount of aerosol generated was dependent on various parameters, such as instrument type, dynamics, articulation and breathing techniques 26 . This is consistent with the findings of Asadi et al. who investigated various speech components and demonstrated that aerosol production increases at loud speech or specific consonants 27 . McCarthy et al. suggest that playing wind instruments emits less aerosol than speaking and singing at high volume 28 . Their study used aerodynamic particle sizers (APS) with funnels, like in previous studies 10 . The categorization of wind instruments by aerosol emission as proposed by He et al. is not supported by McCarthy et al. 28 . They discuss that the aerosol background concentration has a major impact on aerosol measurements and recommend clean room conditions. None of the above-named studies focusing on the nearfield allows to infer long-range transmission risk. Measurement of total particle emission rates during flute and oboe performance is complicated by the non-uniform flow of exhaled air which simultaneously emanates from different openings of the instrument and the mouth of the player. The total flow is, thus, difficult to measure whereas local particle measurements near the instrument would sample an unknown fraction of the total emission. Local aerosol concentration measurements cannot capture integral flow rates unless the total flow through a closed surface around the emission source is known. Local collection of emitted aerosol particles using under-pressure funnels 25 misses aerosol emanation elsewhere, without a chance to estimate the magnitude of the fugitive emission. This is less critical when measuring speaking or singing 10 but introduces systematic errors for instruments with keyholes, particularly the flute. Therefore, McCarthy et al. used two funnels when measuring aerosol emission during flute playing 28 . Advanced collectors have been used by Stockman et al. to reduce the leakage errors during clarinet playing 24 . The observed quick dilution of aerosols entails concentration gradients which limit the accuracy of concentration measurements by adding an accidental dependence on the sampling position. Aerosol mass concentrations, as reported by Eiche 29 , are affected by such local gradients and, additionally, by the nonstationary water content of the particles measured. Measurements of mass concentration depend on the particle size distribution and require calibration of the aerosol spectrometer for the specific kind of aerosol (solid versus liquid) 30 . The initial spontaneous motion of emitted aerosol particles is directed upwards, due to thermal convection, but when they reach the temperature of the surrounding air they mix uniformly with the latter. Eventually, aerosol particles spread all over the premises, following global air flow. The concentrations reached determine inhalation doses of potentially infectious aerosols. For long-range transmission risk assessment, emission rates of airborne aerosol particles have to be known, but they have not been measured during wind instrument playing, so far 19 . Measurement of the spatially uniform aerosol concentration developing after sufficient mixing inside a hermetic probe volume allows calculation of the aerosol emission rate (detailed information in Supplement S3). The entire aerosol released by the proband is diluted in the known amount of air inside the probe chamber and the total emission rate is approximately proportional to the temporal increase of the aerosol concentration. Leakage errors, as by airflow through keyholes, www.nature.com/scientificreports/ do not occur during such a measurement. We measure aerosol concentrations at three remote positions, away from the respiratory plume, and infer the particle emission rate. Dependency on the setting, in particular the ceiling height, has been proposed as possible cause of discrepancy between the results of Abraham et al. 22 and Kähler and Hain 31 . The latter study found a larger extension of the local flow zone. Low headroom accelerates the lateral spreading of aerosols and the formation of uniform concentrations in a probe volume. Accordingly, our setup uses a hermetic probe chamber with low ceiling for accelerated formation of uniform concentrations. Moreover, our probands deliver realistic music performance, rather than playing single notes 28 . The aim of this study is to measure aerosol generation under standardized conditions during the playing of different wind instrument groups. The primary research goal is to measure the total emission rate of airborne aerosol particles while playing wind instruments, including interindividual variation. A secondary question is whether super-spreaders could be defined based on their aerosol emission rate. Lastly, ways to reduce aerosol emission were examined (outlet cover). We use the measured emission rates to predict the probability of COVID-19 transmission in three typical woodwind playing situations. Study design and participants. An exploratory, cross-sectional design was used to measure aerosol emission during wind instrument playing. A convenience sample of volunteer flute, oboe, clarinet, and trumpet players was sought from professional orchestras and students at music conservatories. To qualify for the study musicians had to be at least 18 years of age and to have had professional instrumental education (university degree or similar). Exclusion criteria included acute or severe chronic respiratory diseases and symptoms of a SARS-CoV-2 infection. Recruitment of the participants was accomplished by an informing homepage and an online registration form and was conducted between the end of August and end of October 2020. The measurements took place during October and the first week of November 2020. All measurements were conducted with the approval of the relevant ethics committee of the University Medical Center of Greifswald (reference number BB 131/20) in accordance with the declaration of Helsinki. Every participant gave informed written consent. The study was registered retrospectively on the German Clinical Trials Register (www. drks. de) as No. DRKS00023336. Experimental setup. The measurements took place in an operating theatre of the outpatient surgery centre of Unfallkrankenhaus Berlin, Germany. Room temperature and relative humidity in the theatre were constant, controlled by air conditioning. Room air was primarily filtered by carbon filters and by F7 and F9 bag filters meeting the criteria of EN 779 (average efficiency > 95% for particles of ≥ 0.4 µm). A measuring tent, the probe chamber, was set up in the operating theatre. It consisted of a 20 m 3 cuboid constructed of aluminium bars and impermeable foil (see Fig. 1 ) to prevent air exchange between the inner of the cuboid and the outside during measurements. Between measurements the stale air inside the cuboid was exchanged by opening the empty probe chamber at both ends. A fan and an air purifier with HEPA filter (highefficiency particulate air H13, CARD 210 m 3 /h) accelerated the air exchange after each task. Figure 2 shows an example of time dependent aerosol concentrations during a complete measurement session, featuring oboist no. 7. Airing between measurements went on until aerosol concentrations fell below 50 P/l on all three spectrometers for more than 4 min. The corresponding plots of all participants are available in our repository 32 in the directory fig/Particle Counts. All participants were clothed in a surgical gown and hood and locked in after entry from the side of the probe chamber. During measurements, the upper part of the body was inside the probe chamber, tightly enfolded around the waistline by the sealing foil (see Fig. 1 ). We obtained written informed consent from the participant for publishing the image in an online open-access publication. Spatially resolved measurement of air speed inside the closed cuboid with one participant sitting inside indicated < 0.01 m/s at all positions (measured by a testo 405 i anemometer, see Fig. 1 ). Three aerosol spectrometers (Grimm Aerosol Spectrometers 1.109 and 11-D) were placed in 50 cm (11-D), 150 cm (1.109) and 300 cm (1.109) distance from the participant. A computer monitor was placed to the participants' left sight showing scores or text. To record the sound as audio-track a microphone was placed on the right. The thermo-hygrometer (Voltcraft DL-220THP) and the anemometer were placed next to the aerosol spectrometer positioned at 150 cm distance, see Fig. 1 . Device specifications are reported in Supplement S1. Aerosol concentrations were measured by the three aerosol spectrometers in the unit particles/litre, categorized by size into 31 bins ranging from > 0.25 to > 35 µm, at collection intervals of 6 s. Relative humidity (RH, unit: %) and air velocity (unit: m/s) were measured at 150 cm distance from the participant. Every 2 s air speed was recorded, and every 60 s temperature and humidity. All devices recorded continuously during a whole session, the start and end times were logged by a html-java-script. Tasks. Flute and oboe players were asked to play Mozart's Oboe Concerto in C major K. 314 or Mozart's second Flute Concerto in D major K. 314, respectively (same concerto, originally arranged for flute by Mozart himself). Clarinet and trumpet players played a piece of their own choice 32 . Each recording lasted 20 min. Subsequently, participants were asked to read a text (the beginning of Hermann Hesse's "Der Steppenwolf ", in German) for 20 min, followed by 20 min of quiet breathing. The probands were asked to perform all tasks as normal as possible to achieve realistic breathing patterns, sound volume, and manner of speaking. Data evaluation. The Grimm aerosol spectrometers 1.109 and 11-D use slightly different particle size bins which we transformed into the new size bins > 29.9, > 25.1, > 12.8, > 6.6, > 3.0, > 1.6, > 0.8, > 0.4, > 0.25 µm, as described in Supplement S1. Particles with diameters up to 6.6 µm are further combined to the size bin "aerosol" www.nature.com/scientificreports/ www.nature.com/scientificreports/ whereas larger particles form the bin "droplets". Details of the emission rate calculation are reported in Supplements S2 and S3 and in the document "data processing.pdf " in our repository 32 . All reported estimation uncertainties are calculated by the bootstrap method, as explained in Supplement S2. The aerosol emission rates determine inhalation doses of potentially infectious aerosol particles and allow long-range transmission probability calculations, as outlined in Supplement S4. Data evaluation and statistics were all performed with Wolfram Mathematica 13.0.1 (www. wolfr am. com/ mathe matica). Data sets, supplementary data and figures are available in our repository 32 . For group comparisons we use the two-sided Wilcoxon-Mann-Whitney test at significance level 5%. The Kolmogorov-Smirnov test was applied to distribution fits, at significance level 5%. Descriptive and demographic data of participants are reported in Table 1 . Total aerosol emission rates and particle size distribution. Aerosol emission rates of a total of 32 musicians playing four different wind instruments covered the range from 11 ± 288 particles/second (P/s) to 2535 ± 195 P/s, average rate ± standard deviation (see Fig. 3a for details). The distribution is uniform for both groups, flute D(19) = 0.28, p = 0.08, oboe D(10) = 0.28, p = 0.33. Differences between the flute and oboe groups were not detected, U = 81, p = 0.51. The aerosol emission rates from playing clarinet and trumpet lay within the lower range of the uniform distributed aerosol emission rates from playing flute and oboe. Analysis of the aerosol particle size distribution (see the histogram in Fig. 4 ) shows that about 70 ─ 80% of the emitted particles had a size 0.25-0.8 µm. Particles larger than 6.6 µm (droplets) were rarely detected. The seeming differences between the size distributions of aerosols from different instruments are insignificant since the count fraction estimations overlap to great extent. Since particles smaller than 1 µm penetrate deeply into the respiratory tract, down to the alveolar parenchyma, this aspect is of particular importance with respect to the risk assessment of wind instrument playing. Corporal characteristics like beard wearing had no influence on the aerosol emission rate, probands with such properties did not produce outliers in the distribution. Aerosol emission rates of playing wind instruments compared to speaking and breathing. Aerosol emission rates from music playing were found to be higher than those from speaking and breathing, U = 134, p < 0.001 and U = 62, p < 0.001 respectively. Interestingly, the sole exception (oboist no. 12) shows similar emission rates for both music playing and speaking (660 ± 274 P/s oboe playing, 725 ± 128 P/s speaking). Figure 5 shows the aerosol emission rates from wind instrument playing vs. from speaking. The ellipses indicate the credibility regions and their opacity indicates likelihood. The vast majority of participants produced higher emissions by playing than by speaking. Aerosol emission rates from speaking varied up to 770 ± 152 P/s and from breathing up to 589 ± 354 P/s. Individual aerosol emission rates from speaking were higher than from breathing in most cases. Aerosol protection by using a bell mask. In attempt to reduce aerosol emission, the oboists, the clarinettist, and the trumpeter played with a surgical mask over the bell for 10 min. Due to the shorter measurement time, the relative standard deviations of aerosol emission rates are higher. We find no difference between the www.nature.com/scientificreports/ aerosol emission rates from playing with and without mask, U = 64, p = 0.62. Figure 3b shows a uniform distribution of the aerosol emission rates from playing with a surgical mask around the bell D(12) = 0.17, p = 0.84. Figure 6 compares the aerosol emission rates from playing with and without mask. The semiaxes of the ellipses indicate the standard deviations of estimation uncertainty. The individual aerosol emission rates are consistent between both tasks (playing with and without mask) as indicated by the ellipses intersecting the gray line in most cases, except one outlier showing the expected reduction of emission by the mask (oboist no. 7). Complementary to the total aerosol emission rates, we calculated the total water emission rates from the continuous increase of relative humidity during task performance. The water emission rates show a uniform distribution, flute D (15) www.nature.com/scientificreports/ Fig. 3) . To elucidate the correlation to aerosol emission we calculated their ratio and find that 1 mg emitted water corresponds to ≤ 100 emitted aerosol particles. The ratio was smaller for the task speaking, with two exceptions considered dry high emitters (see Fig. 7 ). Since the humidification of exhaled air takes place in the upper respiratory tract we assume that water emission rates provide important information about the respiratory volume and its circulation in airways. We plotted water emission rates during instrument playing versus speaking and found a factor 2.2 between them Gray lines indicate equal particles-per-water ratios for both tasks. Oboe playing tends to produce larger particles-per-water ratios than speaking while flute playing does not seem to: In diagram (b) more ellipses are located above the grey line than on or below it. The ellipses above the line indicate higher ratios from instrument playing than from speaking. In diagram (a) the distribution of ellipses with respect to the grey line is almost neutral. F19 and F20 are exceptional dry high emitters. www.nature.com/scientificreports/ the ratios of pulmonary ventilation rates during breathing, speaking, and wind instruments playing appear to be very similar for all participants. To our knowledge, this study is the first to examine more than two representatives of the same instrument, but a greater and thus more representative number of individuals for two wind instruments (oboe, flute). Moreover, the study design using a hermetically closed probe chamber and standardized playing condition allowed, for the first time, measurement of total aerosol emission rates. Other than in previous studies 26, 28 the different musicians performed the same repertoire piece of music including a variety of dynamics and articulation techniques. Our experiment resembles a real performance with respect to both the scores and the playing time (20 min). Our results show that typical wind instrument playing generates higher aerosol emissions than typical speaking or calm breathing. During realistic performance, when the musicians play Mozart Concerto as usual, we observe total emission rates in the range previously reported for singing, exceeding 1000 particles per second 33 . This is in line with results by He et al. who found that playing wind instruments in general generates more aerosol than breathing and speaking, whereby the emission rate is dependent on parameters, such as dynamics, articulation, and breathing techniques 26 . Some of the aerosol particle size distributions emitted by our probands during speaking show the laryngeal mode (L-mode) around 2 µm discovered previously 34 32 ). This is consistent with the fact that playing wind instruments does not involve vocal fold vibrations associated with voicing, thus obviating the physical mechanism underlying the generation of L-mode particles. The breathing of the musician is the common source of both the loudness of a wind instrument and the aerosol emission. Specifically, exhalation determines sound generation [35] [36] [37] whereas inhalation determines aerosol generation 11 . Higher loudness is produced by greater exhalation flow rate 35, [38] [39] [40] . A flutist can sustain a note in forte for 8 s without rebreathing, but for 40 s in piano 41 , so the exhalation flow rate increases by an approximate factor five from piano to forte. The aerosol concentration of exhaled air depends on the particle yield of bronchiole fluid film burst which is modulated by the inhalation flow rate 11 . Since aerosol exhalation rate is the product of exhalation air flow rate and particle concentration of the exhaled air, the aerosol emission during playing a woodwind instrument depends on both the inhalation and the exhalation process. A correlation between loudness and aerosol emission is observed 28 because the two quantities correlate, each, with exhalation flow rate as modulator. The median aerosol particle number concentrations reported in McCarthy et al. 28 increase by a factor five from piano to forte, which equals the expected increase of exhalation flow rate during flute playing. The increase of aerosol emission at increasing loudness is, thus, largely explainable by increasing exhalation flow rate. The particles emitted during instrument playing have a similar size distribution as for breathing while speaking and singing would differ thereof by the additional L-mode in the size distribution 11, 28, 34 . During musical performance a musician autonomously adapts both inhalation and exhalation to the artistic requirements 42 so that variation of the inhalation process is ordinary part of wind instrument playing. It introduces an independent modulator of aerosol emission since quicker inhalation, which is typical for flute playing 41 , produces higher aerosol concentrations of the exhalate 11 . Therefore, aerosol emissions from a flute or oboe depend on the playing style in a more complex way than straight correlation with exhalation flow rate or sound pressure. Our probands played a whole Mozart Concerto rather than single notes 28 and playing all the different phrases with the prescribed dynamics requires most of the instrumental and breathing techniques, whereas sustaining a single tone for 20 s is often feasible without re-breathing. When comparing the emissions during instrument playing to those from speaking, we refer to the typical loudness associated with playing the Mozart Concerto or reading the Hesse novel aloud, respectively. The music performance was louder than the reading, and the aerosol emission during playing was higher than during reading aloud. It is possible, though, to raise the voice while speaking to produce similar levels of aerosol emission as by playing wind instruments 28 . The large number of probands playing oboe and flute in our study demonstrated the major individual variability within the two groups. Emission rates show uniform distribution within similar ranges for the two instruments. Unlike previous studies 22, 23, 26 , no clear allocation of emission rates to the instrument type is possible. We conclude that individual factors dominate the variability of aerosol emission rather than the type of instrument. Outliers from the uniform distribution that might be interpreted as super-spreaders have not been observed, other than in a previous study that detected high aerosol emitting probands during speaking 8 . In search for individual factors influencing the aerosol emission we found that emission rates do not correlate with body height or weight 32 . Hence, we assume that the breathing technique and the respiratory rate are probably the reason for individual variability of aerosol emission, as outlined in a recent study 43 . The humidification of exhaled air takes place in the upper respiratory tract 44, 45 whereas aerosol formation is thought to originate deeper in the respiratory tract 11 . Since the humidified air is saturated with water even at high flow rates 46 , water emission likely correlates with pulmonary ventilation rate. Our results indicate higher aerosolparticles-per-water ratios for oboe playing than for speaking. Given that wind instrument playing requires higher pulmonary ventilation rate than speaking, our results are consistent with an increased air exchange in the respiratory tract during wind instrument playing. The required pulmonary volume apparently depends on individual factors, such as vital capacity or breathing technique, which explains the high variability of aerosol emission within the two instrument groups. We found noteworthy correlations between the water emission rates from wind instrument playing, speaking, and breathing indicating that the respiratory volume needed for the respective task might increase similarly for all the different individuals. www.nature.com/scientificreports/ Regarding the particle size distribution, most of the particles are < 1 µm in diameter, as found previously for breathing and speaking probands 33 . The SARS-CoV-2 virus has a diameter of 0.13 µm 47, 48 . An investigation of the load distribution of SARS-CoV-2 virions in airborne aerosol over different aerosol particle size bins revealed that aerosol particles smaller than 1 µm carried 67% of the total number of genome equivalents per cm 3 in an air sample 49 . This imposes great risk for long-range COVID-19 transmission since particles < 2 µm reach alveolar parenchyma. Consistently, particles with equilibrium diameters ≤ 1 µm emitted during breathing, speaking, and singing have been causing indoor airborne long-range COVID-19 transmission with attack rates as high as 89% (51 secondary infections among 57 susceptible exposed) 5 . Even particles emitted by infectious individuals during tidal breathing contain aerosolized SARS-CoV-2 RNA copies, 54% of which are contained in fine particles (diameters ≤ 5 μm) labelled here as "aerosol" 50 . Therefore, the "aerosol" particles emitted during instrument playing ought to be considered efficient virus carriers. The emission rates measured here are the most important input parameter of disease transmission risk calculations for the assessment of indoor situations involving the presence of potentially infectious room occupants. Particles with diameters > 6.6 µm were rarely recorded, in agreement with McCarthy et al. 28 , thus being negligible for long-range, airborne disease transmission. Like other researchers before, we tried to reduce the aerosol emission by masking measures. We masked the bell with a surgical mask on the oboe, clarinet, and trumpet. Except for one oboist, all participants produced similar aerosol emission rates as without mask. A previously described reduction of 50-79% 22, 25 was not observed at the measurement distances used in our study. We assume that aerosol emanated through keyholes and embouchure. Moreover, the most frequent particle class with diameters < 0.8 µm is not filtered efficiently by a surgical mask. Since 4 out of 11 oboists reported a flawed intonation, especially for the notes E5 and F5, while playing with mask we refrain from recommending surgical masks as emission filters for wind instruments. Risk assessment of typical woodwind playing situations. Short-range exposure is difficult to model, but easy to mitigate (by social distancing following recommendations, e.g., in Gantner et al. and Hedworth et al. 21, 51 ). The opposite applies for long-range exposure, in practice. The obvious countermeasures against aerosol transmission are ample fresh air and the wearing of FFP2 masks. However, the efficiency depends strongly on the specific setting. The sole simple rule available is the recommendation to do outdoor whatever can be done outdoor. For indoor occupation, COVID-19 transmission risk can be calculated as described in Reichert et al. 5 and implemented online for free use: https:// hri-pira. github. io 19 . We apply the framework outlined in Supplement S4 to assess the criticality of a few, typical situations of playing woodwinds. It is assumed that appropriate social distancing excludes short-range exposure so that the infection risk entirely results from long-range exposure. As mentioned before, the hazard in a particular scenario depends on both the individual aerosol emission rate q and the infectiousness of the instrument player 52 . In a real situation the disease transmission probability may therefore be a factor 10 less than stated below or even negligible since we assume the worst case of viral load. For our calculations we assume the maximal infectiousness ( Z 50 = 833 particles, for the Delta variant) and an aerosol emission rate of q = 2500 particles per second while playing, to examine whether the setting is safe or not. This question remains important even when an antigen test has been carried out before playing since asymptomatic spreaders may pass at significant rates reported with a sensitivity of 58% to 95% 53 . A safe setting provides the necessary, second line of defense. Vaccination is neglected in the following, thus assuming susceptibility for infection. Lesson at the music school. The teacher and an infectious student have a 60 min lesson in a 200 m 3 classroom. The student listens 50%, plays 40%, and talks 10% of the time (average aerosol emission rate q = 4•10 6 /h). Neither wears a mask and the windows remain closed. The resulting long-range infection probability for the susceptible teacher is p = 96%. To reduce p to 10% by ventilation only, unrealistic 80 air changes per hour (ACH) sustained were necessary. If, instead, the teacher wears a tight FFP2 mask with a filter efficiency of 95% ( ϑ = 0.05) 54,55 then p = 15%. They may open the door and windows widely for 10 min after half an hour to clear the air from aerosols. Then, p = 79% without wearing a mask, or p = 7% wearing a mask. To conclude, acceptable safety levels can be reached even at worst-case conditions by (i) limiting the duration to one hour, (ii) wearing FFP2 mask whenever suitable, and (iii) obligatory, thorough airing around half time. Infection probability with mask is expected around 14% when the space volume of the room is half as large (100 m 3 ). Recital. An infectious soloist plays a one-hour program (net playing time) accompanied by two musicians in a 2000 m 3 ballroom. The audience leaves the room after 90 min, including the encores and applause. Automatic ventilation exhausts air through the ceiling at 2 ACH (4000 m 3 /h) with fresh air streaming inward near the floor. The CO 2 level stays below 1000 ppm (good air quality) for audiences up to 100 persons. The average aerosol emission rate is q = 6•10 6 /h. The long-range infection risk for susceptible persons is p = 3% if they wear FFP2 masks and p = 45% otherwise. Given that social distancing prevents accommodation of more than 50 spectators in the ballroom, one secondary infection case is expected when FFP2 masks are worn throughout. The reproductive number in this setting is R ≈ 1. www.nature.com/scientificreports/ Symphonic performance. A woodwind player in an orchestra is infectious. They play symphonic literature, i.e., the duty cycle of woodwinds is average. We assume 30 min net playing time evenly distributed over 90 min concert duration, resulting in an average aerosol emission rate q = 3•10 6 /h. The concert hall has a space volume of 20,000 m 3 . Automatic ventilation exhausts air above stage and auditorium at 2.5 ACH. The long-range infection risk for susceptible persons is p = 0.14% when they wear FFP2 masks, and p = 3% otherwise, owing to the large air space and fresh air supply. The basic assumption of full mixing, or perfect aerosol dilution, is questionable in the latter example. Concert stages may have air exhaustion ducts which remove part of the air on stage from the hall before it mixes into the air surrounding the audience. In case of the opposite flow direction, fresh air streaming down from the ceiling, problems may arise, such as local stagnation or recirculation regions with elevated aerosol concentrations 51 . Generally, large premises require consideration of actual flows and should not be assessed using the well-mixed room air assumption. Our example cannot be generalized to other concert halls, based only on their size and total fresh air supply. Wind instrument playing, like singing, should be considered more dangerous than speaking or breathing. High interindividual variance of emission rates indicates that physiological factors and playing techniques shape the extent of aerosol formation, rather than the type of instrument. To investigate influencing factors of individual aerosol emission further studies are needed. Our results pave the way to absolute risk calculations for oboe and flute playing in typical situations. Data sets, supplementary data and figures are available in our repository 32 Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant SARS-CoV-2 outbreak investigation in a German meat processing plant Long-distance airborne dispersal of SARS-CoV-2 in COVID-19 wards Probable evidence of fecal aerosol transmission of SARS-CoV-2 in a high-rise building Analysis of Two Choir Outbreaks in Germany in 2020 Characterizes Long-range Transmission Risks Through SARS-CoV-2 Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event Epidemiologic evidence for airborne transmission of SARS-CoV-2 during Church Singing, Australia, 2020. Emerg Aerosol emission and superemission during human speech increase with voice loudness Aerosol emission of adolescents voices during speaking, singing and shouting Comparing aerosol concentrations and particle size distributions generated by singing, speaking and breathing The mechanism of breath aerosol formation CO2 measurements in instrumental and vocal closed room settings as a risk reducing measure for a Coronavirus infection The impact of ubiquitous face masks and filtering face piece application during rest, work and exercise on gas exchange, pulmonary function and physical performance: A systematic review with meta-analysis Close proximity risk assessment for SARS-CoV-2 infection Toward understanding the risk of secondary airborne infection: Emission of respirable pathogens Aerosol Technology. Properties, Behavior, and Measurement of Airborne Particles Extended lifetime of respiratory droplets in a turbulent vapor puff and its implications on airborne disease transmission Airborne spread of measles in a suburban elementary school Predicted infection risk for aerosol transmission of SARS-CoV-2 Airflow and air velocity measurements while playing wind instruments, with respect to risk assessment of a SARS-CoV-2 Infection Impulse dispersion of aerosols during playing wind instruments Risk assessment and mitigation of airborne disease transmission in orchestral wind instrument performance The spread of breathing air from wind instruments and singers using schlieren techniques Measurements and simulations of aerosol released while singing and playing wind instruments Investigation into the release of respiratory aerosols by brass instruments and mitigation measures with respect to Covid-19 Aerosol generation from different wind instruments Effect of voicing and articulation manner on aerosol particle emission during human speech Aerosol and droplet generation from performing with woodwind and brass instruments Studies on aerosol emissions by speaking, singing as a choir or solo, and playing wind instruments Evaluation of optical aerosol spectrometers for the determination of workplace-and corona-relevant aerosols Singing in choirs and making music with wind instruments -Is that safe during the SARS-CoV-2 pandemic? Aerosol emission from playing wind instruments and related COVID-19 infection risk during music performance Emission rate and particle size of bioaerosols during breathing, speaking and coughing Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities Principles of sound production in wind instruments Blowing pressures in reed woodwind instruments. Quarterly Progress and status repor, Speech music and hearing Lexikon der Flöte. Flöteninstrumente und ihre Baugeschichte, Spielpraxis, Komponisten und ihre Werke, Interpreten Air flow and sound generation in musical wind instruments Schule für die Querflöte. Neufassung der Schule für die Böhmflöte Flötenlehre mit vielen Übungen und Spielstücken The simple flute. From A to Z Comparing aerosol number and mass exhalation rates from children and adults during breathing, speaking and singing Humidification of respired gas by nasal mucosa Heat and water exchange in the respiratory tract A technique to measure the ability of the human nose to warm and humidify air Ultrastructural analysis of SARS-CoV-2 interactions with the host cell via high resolution scanning electron microscopy Molecular architecture of the SARS-CoV-2 virus SARS-CoV-2 in residential rooms of two self-isolating persons with COVID-19 Viral Load of SARS-CoV-2 in respiratory aerosols emitted by COVID-19 patients while breathing, talking, and singing Mitigation strategies for airborne disease transmission in orchestras using computational fluid dynamics SARS-CoV-2 aerosol transmission indoors: A closer look at viral load, infectivity, the effectiveness of preventive measures and a simple approach for practical recommendations Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection Efficacy assessment of newly-designed filtering facemasks during the SARS-CoV-2 pandemic Experimental investigation of leckage and separation efficiency of typical face masks and face voers for protection against pathogens Comparison of confidence intervals for a poisson mean: Further considerations Grundlagen der Technischen Thermodynamik 1st edn Numerical recipes in C. The art of scientific computing Size dependence of the ratio of aerosol coagulation to deposition rates for indoor aerosols Measuring indoor fine particle concentrations, emission rates, and decay rates from cannabis use in a residence Deposition of aerosol particles on rough surfaces inside a test chamber Deposition of fine and ultrafine particles on indoor surface materials Review and comparison between the Wells-Riley and dose-response approaches to risk assessment of infectious respiratory diseases Increased transmissibility and global spread of SARS-CoV-2 variants of concern as at Scientific Pandemic Influenza Group on Modelling. SPI-M-O: Consensus statement on COVID-19 European Centre for Disease Prevention and Control. Implications for the EU/EEA on the spread of the SARSCoV-2 Delta (B.1.617.2) variant of concern Evidence for transmission of COVID-19 prior to symptom onset High infectiousness immediately before COVID-19 symptom onset highlights the importance of continued contact tracing Quantifying SARS-CoV-2 transmission suggests epidemic control with digital contact tracing Temporal dynamics in viral shedding and transmissibility of COVID-19 Model calculations of aerosol transmission and infection risk of COVID-19 in indoor environments Alveolar SARS-CoV-2 viral load is tightly correlated with severity in COVID-19 ARDS We wish to thank the Unfallkrankenhaus Berlin and especially Dr. Hajo Schmidt-Traub and Jörg Karst with his team at the Outpatient Surgery Centre for their help in conducting the study. We wish to thank Dr. Udo Jäckel and Daphne Bäger with the team at the Bundesanstalt für Arbeitsschutz und Arbeitsmedizin Berlin for their sustained assistance in measurement procedure and the noteworthy development of the study design. We thank Dr. Chan Yong Schüle for his consultancy in air flow physics and the development of the experimental setup. Finally, we thank the Deutsche Orchester Vereinigung for their help in the recruitment process. Oliver Stier is named as inventor on a patent application filed recently regarding the determination of potentially infectious aerosol air concentrations. All authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-12529-2.Correspondence and requests for materials should be addressed to C.F. Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.