key: cord-0838330-n76iea5g authors: Wan, Zhenzhou; Zhang, Ya’nan; He, Zhixiang; Liu, Jia; Lan, Ke; Hu, Yihong; Zhang, Chiyu title: A Melting Curve-Based Multiplex RT-qPCR Assay for Simultaneous Detection of Four Human Coronaviruses date: 2016-11-23 journal: Int J Mol Sci DOI: 10.3390/ijms17111880 sha: 9b5f7347b52c46ad29b1991560e6251bfdfd8df2 doc_id: 838330 cord_uid: n76iea5g Human coronaviruses HCoV-OC43, HCoV-229E, HCoV-NL63 and HCoV-HKU1 are common respiratory viruses associated with acute respiratory infection. They have a global distribution. Rapid and accurate diagnosis of HCoV infection is important for the management and treatment of hospitalized patients with HCoV infection. Here, we developed a melting curve-based multiplex RT-qPCR assay for simultaneous detection of the four HCoVs. In the assay, SYTO 9 was used to replace SYBR Green I as the fluorescent dye, and GC-modified primers were designed to improve the melting temperature (Tm) of the specific amplicon. The four HCoVs were clearly distinguished by characteristic melting peaks in melting curve analysis. The detection sensitivity of the assay was 3 × 10(2) copies for HCoV-OC43, and 3 × 10(1) copies for HCoV-NL63, HCoV-229E and HCoV-HKU1 per 30 μL reaction. Clinical evaluation and sequencing confirmation demonstrated that the assay was specific and reliable. The assay represents a sensitive and reliable method for diagnosis of HCoV infection in clinical samples. The human coronaviruses (HCoVs) are enveloped, nonsegmented positive strand RNA viruses. They belong to the family coronaviridae, genus coronavirus [1, 2] . Their genomes are 27-31 kb in length. The 5 end of their genome contains two large open reading frames (ORFs), ORF1a and ORF1b, encoding the replicase complex. Genes encoding the structural proteins, i.e., spike (S), envelope (E), membrane (M) and nucleocapsid (N) proteins, are downstream of the ORF1b [1] . Six coronaviruses (HCoV-229E, HCoV-OC43, SARS-CoV, HCoV-NL63, HCoV-HKU1, and MERS-CoV) are known to infect humans [2] . HCoV-229E and HCoV-OC43 were identified in the 1960s [3, 4] . HCoV-NL63 and HCoV-HKU1 were identified in 2004 and 2005, respectively [5, 6] . SARS-CoV was identified during the severe acute respiratory syndrome (SARS) epidemic in China in 2003 [7, 8] , and MERS-CoV was identified during the Middle East respiratory syndrome (MERS) epidemic in the Middle East in 2012 [9] . To develop a melting curve-based multiplex RT-qPCR assay for simultaneous detection of four human coronaviruses (HCoV-OC43, -229E, -NL63 and -HKU1), we designed 10 sets of primers for amplification of the four HCoVs. The theoretical Tm values for 10 amplicons were from 81.44 to 84.97 • C (Table 1 ). In order to select the optimal combination of the primer sets for the four HCoVs, the actual Tm values of 10 specific amplicons were measured by a melting curve analysis. The actual Tm values were from 80.00 to 83.96 • C ( Table 1) . The difference between theoretical and actual Tm values varied from 0.01 to 1.01 • C. To correctly distinguish the four HCoVs, the primer set 1 of each HCoV was selected to combine into a detection group ( Figure 1A) . The corresponding Tm values were 83.39, 83.96, 81.10, and 80.00 for HCoV-229E, HCoV-OC43, HCoV-NL63, and HCoV-HKU1, respectively ( Figure 1A ). Although HCoV-229E, -NL63, and -HKU1 can be clearly distinguished from each other by Tm value, the small difference in Tm values (0.57 • C) between amplicons of HCoV-229E and HCoV-OC43 may result in weak discrimination of both HCoVs. To improve the discrimination between HCoV-229E and HCoV-OC43 amplicons, we developed a strategy to increase the Tm value of the HCoV-OC43-specfic amplicon by modifying the specific primers. First, we generated a series of GC-rich 9-mer oligonucleotides using the shuffle program in the online software package SMS (http://www.bioinformatics.org/SMS/), and added the GC-rich 9-mer oligos into the 5′ end of the HCoV-OC43 primers. Then, we evaluated these GC-modified HCoV-OC43 primers using Vector NTI (Version 11.5.4; Thermo Fisher Scientific Inc., Bedford, MA, USA; http://www.thermofisher.com/cn/zh/home/life-science/cloning/vector-nti-software/vectornti-advance-software/vector-nti-advance-downloads.html) and melting curve analysis (data not shown). One set of GC-modified HCoV-OC43 primers was selected because the Tm value of the corresponding amplicon was improved from 83.96 to 84.88 °C ( Figure 1B) . The GC-modified HCoV-OC43 primers are GC-HCoV-OC43-F: ACGTGCGCGATGTCAATACCCCGGCTGAC and To improve the discrimination between HCoV-229E and HCoV-OC43 amplicons, we developed a strategy to increase the Tm value of the HCoV-OC43-specfic amplicon by modifying the specific primers. First, we generated a series of GC-rich 9-mer oligonucleotides using the shuffle program in the online software package SMS (http://www.bioinformatics.org/SMS/), and added the GC-rich 9-mer oligos into the 5 end of the HCoV-OC43 primers. Then, we evaluated these GC-modified HCoV-OC43 primers using Vector NTI (Version 11.5.4; Thermo Fisher Scientific Inc., Bedford, MA, USA; http://www.thermofisher.com/cn/zh/home/life-science/cloning/vector-nti-software/vectornti-advance-software/vector-nti-advance-downloads.html) and melting curve analysis (data not shown). One set of GC-modified HCoV-OC43 primers was selected because the Tm value of the corresponding amplicon was improved from 83.96 to 84.88 • C ( Figure 1B ). The GC-modified HCoV-OC43 primers are GC-HCoV-OC43-F: ACGTGCGCGATGTCAATACCCCGGCTGAC and GC-HCoV-OC43-R: CCAGGCGGTGGCTCTACTACGCGATCCTG ( Figure 1B) . Compared with the original OC43-F/R primers, the GC-HCoV-OC43-F/R primers also appeared to improve the amplification reactions ( Figure S1 ). When the GC-HCoV-OC43-F/R primers were added into the detection group by replacing the original OC43-F/R primers, four amplicons of HCoVs were clearly distinguished from each other by melting peaks ( Figure 1C ). The corresponding Tm values were 84.88, 83.39, 81.10, and 80.00 for HCoV-OC43, -229E, -NL63, and -HKU1, respectively. These imply the establishment of a melting curve-based quadruplex RT-qPCR for detection of the four HCoVs. To obtain well performance, the primer concentration of the assay was optimized as 0.8 µM, 0.8 µM, 0.8 µM and 0.2 µM of HCoV-229E, -NL63, -HKU1, and -OC43 specific primers, respectively, by orthogonal experiments (Supplemental result and Figure S2 ). The specificity of the melting curve-based multiplex RT-qPCR was assessed using 13 common respiratory viruses. Except the four HCoVs, no amplification was observed for other 9 respiratory viruses, as well as the negative control ( Figure 2A ). Melting analysis showed that except the four HCoVs specific melting peaks, there was no melting peak for other 9 respiratory viruses and negative control ( Figure 2B ). Furthermore, there was also no cross-amplification among these four HCoVs. These indicated that the assay had good specificity for detection of the four HCoVs. GC-HCoV-OC43-R: CCAGGCGGTGGCTCTACTACGCGATCCTG ( Figure 1B) . Compared with the original OC43-F/R primers, the GC-HCoV-OC43-F/R primers also appeared to improve the amplification reactions ( Figure S1 ). When the GC-HCoV-OC43-F/R primers were added into the detection group by replacing the original OC43-F/R primers, four amplicons of HCoVs were clearly distinguished from each other by melting peaks ( Figure 1C ). The corresponding Tm values were 84.88, 83.39, 81.10, and 80.00 for HCoV-OC43, -229E, -NL63, and -HKU1, respectively. These imply the establishment of a melting curve-based quadruplex RT-qPCR for detection of the four HCoVs. To obtain well performance, the primer concentration of the assay was optimized as 0.8 μM, 0.8 μM, 0.8 μM and 0.2 μM of HCoV-229E, -NL63, -HKU1, and -OC43 specific primers, respectively, by orthogonal experiments (Supplemental result and Figure S2 ). The specificity of the melting curve-based multiplex RT-qPCR was assessed using 13 common respiratory viruses. Except the four HCoVs, no amplification was observed for other 9 respiratory viruses, as well as the negative control ( Figure 2A ). Melting analysis showed that except the four HCoVs specific melting peaks, there was no melting peak for other 9 respiratory viruses and negative control ( Figure 2B ). Furthermore, there was also no cross-amplification among these four HCoVs. These indicated that the assay had good specificity for detection of the four HCoVs. Sensitivity of the melting curve-based multiplex RT-qPCR was accessed using serially diluted RNA stocks for the four HCoVs from 1 × 10 6 to 1 × 10 1 copies/μL. The new assay detected 3 × 10 1 copies of HCoV-NL63, -229E and -HKU1, and 3 × 10 2 copies of HCoV-OC43 per 30 μL reaction (Figure 3 ). For the four HCoVs, the calibration curves had high linear relation with R 2 of 0.98 to 1.0. The amplification efficiencies of the new assay for HCoV-229E, -NL63, -HKU1, and -OC43 were 0.86, 0.85, 0.84, and 1.07, respectively ( Figure S3 ). Sensitivity of the melting curve-based multiplex RT-qPCR was accessed using serially diluted RNA stocks for the four HCoVs from 1 × 10 6 to 1 × 10 1 copies/µL. The new assay detected 3 × 10 1 copies of HCoV-NL63, -229E and -HKU1, and 3 × 10 2 copies of HCoV-OC43 per 30 µL reaction (Figure 3 ). For the four HCoVs, the calibration curves had high linear relation with R 2 of 0.98 to 1.0. The amplification efficiencies of the new assay for HCoV-229E, -NL63, -HKU1, and -OC43 were 0.86, 0.85, 0.84, and 1.07, respectively ( Figure S3 ). Figure 3 . Sensitivity of the multiplex RT-qPCR assay using serially diluted RNA stocks. PDs, primer dimers; NTC, non-template control. Among 88 clinical samples, 61 were identified as HCoV-positive, including 52 single infections with one of the four HCoVs and 9 dual-infections with two of the four HCoVs. The detection rate of HCoVs was 69.3%, obviously higher than that (33.0%: 29/88) of the multiplex RT-PCR method used in our previous study. Single infections included 11 HCoV-229E, 22 HCoV-OC43, 16 HCoV-NL63, and 3 HCoV-HKU1. The proportion of dual-infection was 14.8% (9/61), and the dual-infection cases contained 5 HCoV-229E/-OC43, 2 HCoV-229E/-NL63, and 2 HCoV-NL63/-OC43. Among 88 clinical samples, 61 were identified as HCoV-positive, including 52 single infections with one of the four HCoVs and 9 dual-infections with two of the four HCoVs. The detection rate of HCoVs was 69.3%, obviously higher than that (33.0%: 29/88) of the multiplex RT-PCR method used in our previous study. Single infections included 11 HCoV-229E, 22 HCoV-OC43, 16 HCoV-NL63, and 3 HCoV-HKU1. The proportion of dual-infection was 14.8% (9/61), and the dual-infection cases contained 5 HCoV-229E/-OC43, 2 HCoV-229E/-NL63, and 2 HCoV-NL63/-OC43. From 61 HCoVs positive clinical samples identified by the melting curve-based multiplex RT-qPCR, we selected 21 samples having relatively strong melting peak for sequencing confirmation. Blast using the obtained sequences as query sequence revealed there were 2 HCoV-229E, 9 HCoV-OC43, 9 HCoV-NL63, and 1 HCoV-HKU1 sequences ( Figure S4 ). Each obtained sequence corresponded to the right HCoV as judged by the melting curve-based multiplex RT-qPCR assay (Figure S5) , indicating a 100% specificity at least for these sequenced samples. Because HCoVs are one of the most commonly observed pathogens causing respiratory illnesses [2, 10, 11] , the development of reliable and rapid detection method is greatly needed. The multiplex RT-qPCR assay has high sensitivity and specificity, and was often used in the detection of respiratory viruses [27] [28] [29] [30] . A hydrolysis probe-based multiplex RT-qPCR assay was previously developed for HCoV detection [12] . However, difficulty in probe design for highly divergent viruses, as well as high cost in probe synthesis, limits the use of probe-based multiplex RT-qPCR assay. As an alternative to hydrolysis probes, fluorescent dyes (e.g., SYBR geen I) that bind preferentially to double-stranded DNA (dsDNA) have been widely used in the qPCR because they are cheaper than hydrolysis probe. However, because the binding of fluorescent dyes to dsDNA lacks sequence specificity, they are rarely used in the multiplex qPCR. Recently, several melting curve-based multiplex RT-qPCR assays using fluorescent dye were developed for simultaneous detection of bacterial pathogens [33] [34] [35] . Up to our knowledge, no similar method was used for detection of human viruses. In this study, we developed a melting curve-based multiplex RT-qPCR assay for the detection of four HCoVs (HCoV-229E, -OC43, -NL63, and -HKU1). Because SYBR Green I inhibits PCR reaction and preferentially binds to GC rich DNA sequences, which can affect the melting curve analysis [36] , we used fluorescent dye SYTO 9 to replace SYBR Green I in the assay. In order to correctly distinguish the four HCoVs in a single RT-qPCR reaction, we designed four sets of primers to generate four specific PCR products with obviously different Tm values ( Table 1 ). The melting curve analysis showed that the Tm values of the specific products for HCoV-229E, -OC43, -NL63, and -HKU1 were 83.39 • C, 83.96 • C, 81.10 • C, and 80.00 • C, respectively ( Figure 1A ). To further increase the discrimination between HCoV-229E and HCoV-OC43, we developed a strategy to improve the Tm value of HCoV-OC43 amplicon by introducing a 9-mer GC-rich oligonucleotide into the 5 end of the specific primers. The GC-modified OC43 primers generated an amplicon with Tm value of 84.88 • C, 0.92 • C higher than that obtained with the original OC43 primers ( Figure 1B) . Under the new primer sets, the melting curve-based multiplex RT-qPCR assay can well detect and distinguish the four HCoVs ( Figure 1C) . The detection sensitivity of the new assay was determined using the standard strains or in vitro transcribed RNA of the four HCoVs. The detection sensitivity was 3 × 10 2 copies/µL for HCoV-OC43, and 3 × 10 1 copies/µL for HCoV-NL63, HCoV-229E and HCoV-HKU1 (Figure 3 ). The specificity of the assay was assessed using a panel of respiratory viruses commonly found in children with acute respiratory infection. No amplification signal was observed for any of the strains except the four targeted HCoVs (Figure 2 ). Using the new assay, we detected 88 clinical samples. Among them, 61 were identified as HCoV-positive, including 9 dual infections with two of the four HCoVs. To confirm the results, we selected 21 samples (including 9 HCoV-OC43, 9 HCoV-NL63, 2 HCoV-229E and 1 HCoV-HKU1) from these positive samples for sequencing confirmation. The sequence and blast results of the 21 samples were completely consistent with that obtained by the melting curve-based multiplex RT-qPCR assay (Figures S4 and S5) . Furthermore, non-specific amplification was not observed when pooled samples were used (data not shown). These results indicated that the new assay was reliable. In summary, we developed a melting curve-based multiplex RT-qPCR assay for simultaneous detection of HCoV-229E, HCoV-OC43, HCoV-NL63 and HCoV-HKU1. The assay is a sensitive and reliable method for screening of HCoV infection in clinical samples (e.g., nasopharyngeal swabs). In addition, we developed a strategy to improve the Tm value of amplicon by adding GC-rich oligonucleotides to the 5 end of the related primers. A total of 88 nasopharyngeal swabs from outpatient children with fever and respiratory symptoms in Shanghai Nanxiang Hospital were used in this study for clinical evaluation. The samples were obtained from two previous studies with 59 being identified as HCoV-positive using a multiplex RT-PCR [37, 38] . During this study, these samples were re-detected using the same method. Only 29 were identified as HCoV-positive, which may be ascribed to degradation of viral RNA among these samples caused by multiple freezing and thawing. The study was approved by the Ethics Committee of Taizhou All available genomic sequences of HCoV-229E, HCoV-OC43, HCoV-NL63, and HCoV-HKU1 were downloaded from GenBank, and aligned using MEGA 5.05 (http://www.megasoftware.net/) to find the most conserved region. The M gene of HCoV-229E, and N genes of HCoV-OC43, HCoV-NL63, and HCoV-HKU1 were selected as target region for primer design. The primers were designed using Primer Express 3.0 software (Applied Biosystems, Foster City, CA, USA), and their specificity was confirmed by a Nucleotide BLAST search. In order to develop a multiplex RT-qPCR assay based on melting analysis for simultaneous detection of the four HCoVs, the primers were designed to generate amplicons with different melting temperature (Tm) for different coronavirus. Three sets of primers were designed for HCoV-229E, -OC43, and -HKU1, and one set of primers was for HCoV-NL63 ( Table 1 ). The theoretical Tm of each amplicon was predicted using the online tool Oligo Calc: Oligonucleotide Properties Calculator (Northwestern University, Chicago, IL, USA), (http://biotools. nubic.northwestern.edu/OligoCalc.html) based on the amplicon sequence [39] . Actual Tm of the amplification product was determined by the melting curve analysis. The RT-qPCR was performed using QIAGEN OneStep RT-PCR Kit (QIAGEN, Hilden, Germany) with SYTO 9 (Life technologies, Carlsbad, CA, USA) as the fluorescent dye. Thirty µL reactions including 3 µL template input were run on a Light Cycler 96 RT-qPCR System (Roche Diagnostics, Mannheim, Germany). Reaction conditions were: 30 min RT at 50 • C, 15 min at 94 • C for inactivation of reverse transcriptase (RT), followed by 40 cycles of 94 • C for 30 s, 50 • C for 30 s and 72 • C for 1 min. Melting curve analysis was performed under the condition of 95 • C for 60 s, 40 • C for 60 s, 65 • C for 1 s, then followed by a slow increase from 65 • C to 95 • C with a speed of 0.07 • C per second. The specificity of the melting curve-based multiplex RT-qPCR was assessed using 13 common respiratory viruses including 9 standard strains and 4 clinical isolates. The 9 standard strains were described above and the 4 clinical isolates were PIV1, PIV2, PIV4, and HCoV-NL63. Because there was no standard strain and clinical isolate available for HCoV-HKU1, we synthesized plasmid containing HCoV-HKU1 N gene downstream of the T7 promoter. HCoV-HKU1 RNA was obtained via in vitro transcription. Using the same strategy, we also obtained the RNA stocks of HCoV-229E, HCoV-OC43, and HCoV-NL63 for sensitivity experiments. Serially diluted RNA stocks for four HCoVs from 1 × 10 6 to 1 × 10 1 copies/µL were used to determine the detection limit of the melting curve-based multiplex RT-qPCR. A total of 88 clinical samples were used to evaluate the performance of the melting curve-based multiplex RT-qPCR for four HCoVs detection. To avoid the possibility of the non-specific PCR product with same or similar Tm value to specific products, we confirmed the detection results by sequencing the amplicons. Because the weak melting peak implies few amplification products that are not enough for direct DNA sequencing, we selected the amplification products with strong melting peaks for sequencing confirmation. Of HCoV-positive clinical samples identified by the multiplex RT-qPCR, 21 were subjected to sequencing confirmation, including 2 HCoV-229E, 9 HCoV-OC43, 9 HCoV-NL63, and 1 HCoV-HKU1. The sequencing reactions were performed by Shanghai Biosune Biotechnology Co., Ltd. (Shanghai, China). Genome structure and transcriptional regulation of human coronavirus NL63 Epidemiology, genetic recombination, and pathogenesis of coronaviruses A new virus isolated from the human respiratory tract Recovery in tracheal organ cultures of novel viruses from patients with respiratory disease Characterization and complete genome sequence of a novel coronavirus, coronavirus HKU1, from patients with pneumonia Identification of a new human coronavirus Identification of a novel coronavirus in patients with severe acute respiratory syndrome A novel coronavirus associated with severe acute respiratory syndrome MERS: Emergence of a novel human coronavirus Burden of respiratory syncytial virus infections in China: Systematic review and meta-analysis High incidence but low burden of coronaviruses and preferential associations between respiratory viruses Epidemiology and clinical presentations of the four human coronaviruses 229E, HKU1, NL63, and OC43 detected over 3 years using a novel multiplex real-time PCR method Recently discovered human coronaviruses Coronavirus 229E-related pneumonia in immunocompromised patients Fatal lower respiratory tract disease with human corona virus NL63 in an adult haematopoietic cell transplant recipient Human coronaviruses: Insights into environmental resistance and its influence on the development of new antiseptic strategies A line immunoassay utilizing recombinant nucleocapsid proteins for detection of antibodies to human coronaviruses Diagnosis of human coronavirus infection by immunofluorescence: Method and application to respiratory disease in hospitalized children Serological assays for emerging coronaviruses: Challenges and pitfalls Monoclonal antibodies versus reverse transcription-PCR for detection of respiratory viruses in a patient population with respiratory tract infections admitted to hospital Cross-reactive antibodies in convalescent SARS patients' sera against the emerging novel human coronavirus EMC (2012) by both immunofluorescent and neutralizing antibody tests Serological responses in patients with severe acute respiratory syndrome coronavirus infection and cross-reactivity with human coronaviruses 229E, OC43, and NL63 Polymerase chain reaction is more sensitive than viral culture and antigen testing for the detection of respiratory viruses in adults with hematological cancer and pneumonia Simultaneous detection of respiratory viruses in children with acute respiratory infection using two different multiplex reverse transcription-PCR assays Development of a multiplex one step RT-PCR that detects eighteen respiratory viruses in clinical specimens and comparison with real time RT-PCR Evaluation of custom multiplex real-Time RT-PCR in comparison to fast-Track diagnostics respiratory 21 pathogens kit for detection of multiple respiratory viruses Evaluation of the AdvanSure real-time RT-PCR compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses Development and evaluation of a four-tube real time multiplex PCR assay covering fourteen respiratory viruses, and comparison to its corresponding single target counterparts Comparison of the AdvanSure™ real-time RT-PCR and Seeplex ® RV12 ACE assay for the detection of respiratory viruses Detection of human coronaviruses in simultaneously collected stool samples and nasopharyngeal swabs from hospitalized children with acute gastroenteritis Frequent detection of human coronaviruses in clinical specimens from patients with respiratory tract infection by use of a novel real-time reverse-transcriptase polymerase chain reaction Real-time multiplex PCR assay and melting curve analysis for identifying diarrheagenic Escherichia coli Multiplex real-time PCR assay and melting curve analysis for identifying mycobacterium tuberculosis complex and nontuberculous mycobacteria A probe-free four-tube real-time PCR assay for simultaneous detection of twelve enteric viruses and bacteria Comparison of SYTO9 and SYBR Green I for real-time polymerase chain reaction and investigation of the effect of dye concentration on amplification and DNA melting curve analysis Genetic variation of human respiratory syncytial virus among children with fever and respiratory symptoms in Epidemiological and clinical characteristics of respiratory viral infections in children in Shanghai An online oligonucleotide properties calculator