key: cord-0837789-uzjm966u authors: Dada, Christopher Ayokunle; Gyawali, Pradip title: Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants date: 2020-10-15 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2020.142989 sha: 38a8a078547be4915b89d1a67954c8697e5f18e0 doc_id: 837789 cord_uid: uzjm966u The current global Severe Acute Respiratory Syndrome- Coronavirus-2 (SARS-CoV-2) epidemic has heightened calls for studies to evaluate respiratory exposure for wastewater treatment workers. In this global first study, we assess occupational health risks to wastewater treatment plant (WWTP) operators from inhalation of aerosolized SARS-CoV-2 using a Quantitative Microbiological Risk Assessment (QMRA) framework. The following considerations were used to develop the QMRA and assess the illness risks to workers: a) the proportion of the population who are infected and thus responsible for shedding SARS-CoV-2 into raw wastewater; b) the concentration of SARS-CoV-2 in raw and treated wastewater; c) the volume of aerosolized water inhaled by a WWTP operator during work; d) humidity and temperature-dependent viability of coronaviruses in aerosolized waste water; e) estimation of the amount, frequency, and duration of exposure; and f) exposure doses. The variables were then fed into an exponential dose response model to estimate the risks in three scenarios representing low-grade, moderate and aggressive outbreaks. These scenarios were designed on the assumption of 0.03%, 0.3% and 3% of the wastewater-generating population being infected with SARS-CoV-2. In terms of averaged-out illness risk profiles, the individual illness risks for low grade, moderate and aggressive outbreak scenarios respectively are 0.036, 0.32 and 3.21 illness cases per 1000 exposed WWTP operators. Our study suggests that the risk of accidental occupational exposure to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment, is negligible, particularly when less than 0.3% of the population served by the plant are actively infected. A novel coronavirus disease named COVID-19 emerged from China in 2019 and rapidly spread throughout the world (WHO, 2020) . The International Committee on Taxonomy of Viruses named the virus responsible for this outbreak as Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) (Nghiem et al., 2020; Wu et al., 2020) . Despite several public health strategies, the daily total number of COVID-19 cases globally has not slowed down (WHO, 2020a) . Eleven months on, this virus has caused 35.5 million illness cases and 1.04 million deaths, as of October 2020 (Worldometer, 2020) . Published studies have reported faecal shedding of the SARS-CoV-2 virus from symptomatic and asymptomatic individuals before and during the onset of symptoms (Lescure et al., 2020; Nghiem et al., 2020; WHO, 2020c; Wu et al., 2020) . Several studies also detected SARS-CoV-2 RNA in stools and wastewater (Ahmed et al., 2020; Bogler et al., 2020; Medema et al., 2020; Randazzo et al., 2020; Singer and Wray, 2020) . Given these considerations, there have been concerns about the possibility of indirect or direct transmission of SARS-CoV-2 via exposure to untreated or treated wastewater (Ashour et al., 2020; Bogler et al., 2020; Cheung et al., 2020; Kitajima et al., 2020) . A Water Environment Federation blue-ribbon panel of experts commissioned to evaluate the safety of wastewater workers during the coronavirus pandemic recommended that studies should be conducted to evaluate respiratory exposure during tasks performed by workers in wastewater collection and treatment (TPO, 2020) . Other independent studies have also called for QMRAs to evaluate respiratory exposure associated with wastewaters (Amoah et al., 2020; Kitajima et al., 2020) . This is particularly relevant to aerosolization of wastewater J o u r n a l P r e -p r o o f Journal Pre-proof and thus accidental exposure of wastewater operators to SARS-CoV-2 during daily workplace activities such as manual cleaning, coarse screening, wastewater sampling for microbiological and chemical analysis, and process supervision. Reference pathogens including norovirus, enterovirus and adenovirus were used for QMRAs in relation to WWTP influents (Dada, 2018a (Dada, , 2018b (Dada, , 2019a (Dada, , 2019b (Dada, , 2020a (Dada, , 2020b McBride, 2007 McBride, , 2011 McBride, , 2016a McBride, , 2016b McBride et al., 2013) . Recently, Zaneti et al (2020) applied SARS-CoV-2 as the reference QMRA pathogen considering ingestion via the faecal oral route. There is a dearth of published information on risk assessments focused on coronavirus spread through exposure to SARS-CoV-2 via inhalation. In this study, SARS-CoV-2 was used as the reference QMRA pathogen to assess health risks during occupational exposure by inhalation in wastewater treatment environments. Information related to treatment type, population covered and location of each wastewater treatment plant (WWTP) was extracted from an online inventory collated during the National Performance Review for 2018. Information from over 300 publicly owned WWTPs in New Zealand was collected and analysed for QMRA purposes. Wastewater stabilization ponds (WSPs) are the most prevalent form of wastewater treatment used for treating domestic sewage from small to medium-sized communities in New Zealand (Figure 1 ). WSPs generally encompass three different pond systems: oxidation (mechanical), aerated, and anaerobic ponds (WaterNZ, 2005) . WSPs are used either wholly J o u r n a l P r e -p r o o f Journal Pre-proof or in combination with other forms of treatment (e.g. aeration lagoons, wetlands, sand filters, membrane filtration, and ultraviolet based disinfection). In terms of populations served by WWTPs, activated sludge (AS) systems are the most popular treatment systems ( Figure 1 ). Activated sludge (AS) systems are also the most widely used biological wastewater treatment process in the developed world (Scholz, 2015) . Pond-based systems are considered as self-sufficient treatment units, because the efficacy of treatment is contingent upon the maintenance of the overall microbial communities (Hosetti et al., 1998; Hosetti and Frost, 1995) , and the proper balance of organics, light, dissolved oxygen, nutrients, algal presence (Amengual-Morro et al., 2012) , and temperature. Because pond-based treatment systems are self-sufficient, there is a reduction in operator responsibilities to manage the treatment unit (Butler et al., 2017; Hosetti et al., 1998) . However, WWTP operators may still be required to perform routine activities including manual cleaning, coarse screening, and wastewater sampling for microbiological and chemical analysis. WWTP operators working with activated sludge systems also perform similar activities. As a result, WWTP operators can be exposed to aerosolized form of SARS-CoV-2 via wind or mechanically generated aeration. The formation of wastewater aerosols and droplets was confirmed as a key mechanism for faecal-droplet-respiration transmission during previous coronavirus outbreaks and is suspected in the current COVID-19 outbreak caused by SARS-CoV-2 (Ding et al., 2020; Gormley et al., 2020; Yu et al., 2004) . Aerosolized human coronaviruses remain viable for up to 16 hours (Fears et al., 2020; Van Doremalen et al., 2020) . Although dispersal of larger droplets is limited, as they deposit close to the source, larger droplets can cause local contamination of surfaces due to their enhanced capacity to ii. SARS-CoV-2 concentrations in raw wastewater; iii. How much aerosolized water a WWTP operator will inhale during a working day; iv. Humidity and temperature-dependent viability of coronaviruses in aerosolized form; and, v. Estimation of the amount, frequency, length of time of exposure, and doses for exposure (see Table 1 ). SARS-CoV-2 concentrations in wastewater that arrive at the WWTP This study assumes a conservative stance in which all individuals who have been previously or are currently infected (symptomatic or asymptomatic) continue to shed the virus in their stools. One of the key factors influencing the occurrence of coronaviruses in wastewater is the concentration of virus shed by infected individuals (Cai et al., 2020; Zhang et al., 2020) . Literature has shown concentrations of SARS-CoV-2 in stool of infected individual ranged between 1.7 x 10 6 to 4.1 x 10 7 genome copies (Han et al. 2020 in Amoah et al. 2020 . In J o u r n a l P r e -p r o o f Journal Pre-proof accordance with previous WWTP QMRA reports and international literature (e.g. McBride 2016a,b), median (1.7 x 10 6 genomes per mL) and maximum (4.1 x 10 7 genomes per mL) stool virus concentrations were bounded in the hockey-stick distribution in such a way that the resulting data are strongly right-skewed with a hinge at the 95 th percentile. This therefore presents, in the same population, the generally predominant lower virus concentrations (i.e. having higher probabilities) alongside the extreme concentrations (which may be rare, but substantial). Generally, some levels of dilution occur given that greywater and other forms of wastewater become mixed with stools once flushed down the toilet. Two scenarios were thus considered. I. No dilution scenario: Stools from individuals shedding SARS-CoV-2, flushed down the toilet, are not diluted at all and reach the WWTP as influent. It was assumed to contain SARS-CoV-2 concentrations of most likely between 1.7 x 10 6 genomes per mL (median) and 4.1 x 10 7 genomes per mL (maximum) (i.e. dilution factor = 1). Dilution scenario: The average person passes about 30 mL of stool a day for every five kilograms of body weight. This translates to approximately 192 to 510 mL of stool per individual. Typically, the amount of water used in the toilet for one full flush is 6L. That is, for every single toilet use per individual shedding SARS-CoV-2, the concentration is diluted roughly 12 to 31 times. A dilution factor (stool_DF) distributed between 12 and 31 was therefore included in the modelling. Prevalence-dependent SARS-CoV-2 loading Three different scenarios (low, moderate and aggressive), representing different proportions of the population infected with the virus, were applied in this study. Low outbreak, moderate outbreak, and aggressive outbreak scenarios assume that 0.03%, 0.3% and 3%, respectively, of the population being served by a WWTP are infected and are shedding SARS-CoV-2 in their stools. Given this consideration, the virus concentration expected at the WWTP is: Where is the number of individuals infected in a population being served by a WWTP, is the SARS-CoV-2 concentration in the stools of infected individuals, _ is the total population being served by a WWTP, _ is the stool dilution factor. Virus reductions achieved before and during treatment at the WWTP The final virus concentrations in WWTP wastewater on a random day were then subjected to varying log removals (depending on the wastewater treatment scenario considered) before they were incorporated into the QMRA. It was assumed that before aerosolization, human coronaviruses in raw wastewater and the residual coronavirus concentrations following treatment all remain viable. Given these considerations, the SARS-CoV-2 virus concentration in wastewater for each WWTP treatment scenario is therefore: Where log is 1, 10, 100, 1000-and 10,000-fold reduction respectively for 0,1,2,3 and 4 log-removals achieved during treatment at the WWTP. Among the meteorological factors, humidity (relative humidity; RH and absolute humidity; AH) and temperature play an important role in the viability status of coronaviruses in the air. Published literature has shown that 60% of coronaviruses in droplets or aerosols remain infectious for up to an hour at a RH of 79% at 25 0 C but at a higher temperature and lower RH of 38 0 C and 24%, less than 5% remained infectious. Recent studies have also suggested that AH rather than RH modulates virus survival (Deyle et al., 2016; McDevitt et al., 2010; Shaman and Kohn, 2009; Shaman et al., 2010 Where AH is absolute humidity in gm-3, RH is relative humidity in percent and T is in 0 C, applicable over a temperature range of -40 to 50 0 C, and: Viability of aerosolized coronavirus (%) = −0.0515 * AH + 2.0487 Given these considerations, the viable concentration of aerosolized SARS-CoV-2 is therefore given as: (Dorevitch et al., 2011; Dufour et al., 2006; Haas et al., 1999) to arrive at minimum, mode and maximum associated volumetric intake rates of 10, 50 and 100 mL for ingestion associated with primary contact. In this study, it was assumed that WWTP operators would be physically present at the WWTP vicinity for a J o u r n a l P r e -p r o o f Journal Pre-proof median and maximum period of 4 and 8 hours on any random day, with associated volumetric intake rates of 2, 10 and 20 mL per hour (Table 1) Carlo simulation is a randomization method that applies multiple random sampling from distributions assigned to key input variables in a model, in a way that incorporates the uncertainty profiles of each key input variable into the uncertainty profile of the output. Typically, in a Monte Carlo model run, 100 individuals who do not have prior knowledge of existing contamination in the wastewater and who do not wear protective nose coverings are 'exposed' to potentially infectious aerosolised pathogens on a given day and this exposure is repeated 1,000 times. Therefore, the total number of exposures is 100,000. The result of the analysis is a full range of possible risks, including average and worst-case scenarios, associated with exposure to pathogens during the identified recreational activities. Monte Carlo simulations were undertaken using @Risk software (Palisade, NY). QMRA results are reported in terms of illness, assuming a conservative stance in which every single infection leads to illness. The predicted risk is reported as the IIR (individual illness risk), calculated as the total number of illness cases divided by the total number of exposures, and is expressed as a percentage. The IIR is then compared with a threshold of 1 illness per 1000 exposed individuals as specified in the WHO interim guidance document. This threshold is considered the no observable adverse effects level (NOAEL). Presented in Figure 4a there would be no more than one illness case among 100 WWTP operators accidentally exposed to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment, on any random day during low grade outbreak conditions (i.e. 0.03% of the population served by the WWTP is infected). In comparison, 95% of the time, there would be no more than three illness cases recorded during moderate outbreak conditions (i.e. 0.3% of the population served by the WWTP is infected). During aggressive outbreak conditions (i.e. when 3% of the population served by the WWTP is infected), the risk profiles are markedly higher with up 14 illness cases predicted among 100 WWTP operators accidentally exposed to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment, 95% of the time on any random day (Figure 4c ). These elevated risks would also remain if, during conditions of aggressive outbreak, WWTP operators were exposed to partially treated wastewater in processing units where wastewater virus reductions of less than 1log had been achieved (Figure 4c ). Cumulatively, in terms of averaged-out illness risk profiles, the individual illness risks for low J o u r n a l P r e -p r o o f grade, moderate and aggressive outbreak scenarios, respectively, are 0.691, 6.8 and 62.4 illness cases per 1000 individuals (Figure 4a-c) . In the more realistic scenario where dilution of the stool with toilet flush water was included in the risk assessment (Figure 4d) , 99% of the time there would be no illness case among 100 WWTP operators accidentally exposed to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment, on any random day during low-grade outbreak conditions (i.e. 0.03% of the population served by the WWTP is infected). However, 99% of the time, there would be no more than 1 and 4 illness cases, respectively, per 100 exposed WWTP operators during moderate and aggressive outbreak conditions (Figure 4e-f ). Cumulatively, in terms of averaged-out illness risk profiles, the individual illness risks for low-grade, moderate and aggressive outbreak scenarios respectively are 0.036, 0.32 and 3.21 illness cases per 1000 exposed WWTP operators (Figure 4d-f ). This study was conducted in response to concerns that populations at greatest risk in the ongoing SARS-CoV-2 pandemic may be WWTP operators who may be exposed to raw wastewater. Our study is the first ever QMRA study that has assessed the potential level of occupational exposure of WWTP operators to SARS-CoV-2 via inhalation. This study is also the second QMRA study published that has assessed the potential level of occupational exposure of WWTP operators to SARS-CoV-2. A previously published QMRA report (Zaneti et al., 2020) (2020) study also did not include consideration of contaminated surfaces in the modelling, despite these sources being potential vital links in the transfer of SARS-CoV-2 through the oral route. Our study is an improvement upon the first QMRA report in that it focuses on human health risks during accidental inhalation of aerosolized forms of the wastewater. In selecting QMRA input parameters, this QMRA included considerations for most of the factors that have been suggested as crucial to the fate of SARS-CoV-2 in the WWTP environment (Amoah et al., 2020) . In addition to inhalation rate and exposure time, this study also included considerations of humidity and temperature-dependent survival of SARS-CoV-2 in aerosolized form based on a viability model for influenza viruses (Kong et al., 2020) . The influenza viability model applied to estimate humidity and temperature-dependent survival of aerosolized SARS-CoV-2 is justified because it has been detected in patients with influenza-like illness (Kong et al., 2020) . This study also adds to the body of scholarly literature in that it considers the assessment of occupational health risks associated with accidental exposure to SARS-CoV-2 following logremovals that are typically achieved in WWTPs. The observation that risk profiles were highest for raw wastewater but generally reduced with increasing orders of log reduction is expected. Overall, in the more realistic scenario where dilution of the stool with toilet flush water was included in the risk assessment, our results show cumulative illness risk (mean) was less than 1 per 1000 exposures for low-grade and moderate outbreak scenarios.. This indicates that J o u r n a l P r e -p r o o f Journal Pre-proof the risks of accidental occupational exposure to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment are negligible. It is, however, important to mention that in terms of the upper limit (i.e. 99 th percentile), a low level of risk was observed. These predicted health risks, however, only occur during extreme values of the QMRA input components were used. For instance, a WWTP operator exposed to raw or partially treated wastewater for 8 hours continuously that is very unlikely unless WWTP staff are manually ).There was still uncertainty as to whether these viral RNA detection rates actually correlate with the presence of infectious virus. In a recent study (Wölfel et al., 2020) , high concentrations (up to 10 8 ) of viral fragments similar to those in sputum were reported based on 13 stool samples taken within 12 days from 4 patients. Unlike the case for sputum, an attempt to grow SARS-CoV-2 from stool was not successful. However, contrasting results were published in another study where SARS-CoV-2 was successfully cultured from faeces of a critically ill patient in China (Xiao et al., 2020) . While the number of samples analysed in this study is very small (n=3), it points to the possibility of the RNA in faeces being infective. Wölfel et al. (2020) submitted that more studies would be needed to address whether SARS-CoV-2 shed in stool is rendered non-infectious though contact with the gut environment. Given this possibility of infectivity of RNA viruses in stools, albeit at levels not currently known, it was considered safe to assume in this QMRA that all viral RNA in stool was infectious. This QMRA also excluded opportunities for dilution of stools from infected individuals; hence it involved higher SARS-CoV-2 concentrations in the raw wastewater that reached the WWTP. Generally, in addition to the levels of dilution that occur at the toilet level (i.e. with toilet flush water), more dilution can occur within the sewerage system. For instance, J o u r n a l P r e -p r o o f greywater and other forms of wastewater (e.g. from baths, sinks, washing machines, and other kitchen appliances) from houses connected to reticulated sewerage systems become mixed with the stools once flushed down the toilet, en route to the WWTP. As the available literature suggests that dish, shower, sink, and laundry water comprise 50-80% of residential wastewater (Al-Jayyousi, 2003) , higher dilution possibilities indicate that the reported risks in this QMRA may be overstated. It should be noted that the coronavirus dose response models used in this study was based on an infection endpoint, as reported by Watanabe et al. (2010) . In our study, we have assumed a worst-case scenario where every infected individual becomes ill. In reality, infection may not necessarily progress to illness. For instance, while healthy individuals may not necessarily become ill, the elderly and immune-compromised citizens may present with a different response effect for the same dose of SARS-CoV-2. Even among the healthy, differential immunity status may exist (McBride et al., 2013) . Although this study also considered risks following treatment at the WWTP, this study did not focus on a specific wastewater treatment but used a more generalizable range of treatments. that could be potentially achieved at various WWTPs in New Zealand and elsewhere. These included scenarios for virus removal (i.e. raw wastewater) as well as 1,2,3, and 4 log virus removals equivalent to 10, 100,1000 and 10,000-fold reductions in viral loads, respectively. These represent the range of virus log reductions that have been associated with various forms of wastewater treatment, e.g. 1 log 10 in wastewater pond treatment systems (Verbyla et al (2015) ) and between 2-4 log 10 removals in activated sludge and J o u r n a l P r e -p r o o f membrane bioreactor systems (De Luca et al., 2013; Wen et al., 2009; Zhang and Farahbakhsh, 2007) . More studies are still needed to characterize SARS-CoV-2 in the faeces of active and recovered individuals. Stool virus concentrations and infectivity analysis of a larger sampling scale would be useful to improve the quality of future QMRAs. Care should be exercised to ensure a harmonization of laboratory-generated genomic concentrations of SARS-CoV-2 and doses applied in future QMRAs. For instance, while the coronavirus dose response model in Watanabe et al. (2010) was based on plaque-forming units, there may be multiple virus particles for each PFU as viral particles that are defective or which fail to infect their target cell will not produce a plaque and thus will be inadvertently excluded from the plaque count. Our study suggests that the risk of accidental occupational exposure of SARS-CoV-2 in raw wastewater via inhalation at the WWTP environment is low. Despite the highly conservative stance that this QMRA adopts, generally low individual illness risks were predicted during low-grade and moderate outbreak conditions (when less than 0.03% and 0.3% respectively, of the population served by a WWTP are actively infected). Rethinking wastewater risks and monitoring in light of the COVID-19 pandemic Oxidation pond for municipal wastewater treatment A Case Series of children with 2019 novel coronavirus infection: clinical and epidemiological features Gastrointestinal manifestations of SARS-CoV-2 infection and virus load in fecal samples from the Hong Kong cohort and systematic review and meta-analysis Quantitative Microbial Risk Assessment for the discharge of treated wastewater at Army Bay Quantitative Microbial Risk Assessment for the discharge of treated wastewater into Whitford Embayment through Turanga Creek, LCL1702, Streamlined Environmental Microbial Evidence for Waikato Region Plan Change (WRPC1) hearing Quantitative Microbial Health Risk Assessment for wet weather wastewater discharges into city rivers and Poverty Bay Quantitative Microbial Risk Assessment for the discharge of treated wastewater from the Opononi WWTP into the Hokianga Harbour, FNDC1802, Streamlined Environmental Quantitative modelling of public health risk associated with stormwater network improvements Removal of indicator bacteriophages from municipal wastewater by a full-scale membrane bioreactor and a conventional activated sludge process: Implications to water reuse Global environmental drivers of influenza Toilets dominate environmental detection of SARS-CoV-2 virus in a hospital Water ingestion during water recreation Water ingestion during swimming activities in a pool: a pilot study Comparative dynamic aerosol efficiencies of three emergent coronaviruses J o u r n a l P r e -p r o o f and the unusual persistence of SARS-CoV-2 in aerosol suspensions COVID-19: mitigating transmission via wastewater plumbing systems Quantitative microbial risk assessment A review of the control of biological waste treatment in stabilization ponds A review of the sustainable value of effluents and sludges from wastewater stabilization ponds Development of a novel real-time polymerase chain reaction assay for the quantitative detection of Nipah virus replicative viral RNA SARS-CoV-2 in wastewater: State of the knowledge and research needs. Sci. Total Env SARS-CoV-2 detection in patients with influenza-like illness Clinical and virological data of the first cases of COVID-19 in Europe: a case series Microbial Risk Assessment Modeling. Statistical Framework for Recreational Water Quality Criteria and Monitoring A Quantitative Microbial Risk Assessment for Napier City's ocean outfall wastewater discharge. Report Prepared by NIWA for Napier City Council Quantitative Microbial Risk Assessment for the Discharge of Treated Wastewater: Snells Beach Wastewater Treatment Plan. Report Prepared by NIWA for Watercare Services Limited Quantitative Microbial Risk Assessment for the Discharge of Treated Wastewater: Warkworth Wastewater Treatment Plan. Report Prepared by NIWA for Watercare Services Limited Discharge-based QMRA for estimation of public health risks from exposure to stormwater-borne pathogens in recreational waters in the United States Role of absolute humidity in the inactivation of influenza viruses on stainless steel surfaces at elevated temperatures Presence of SARS-Coronavirus-2 in sewage The COVID-19 pandemic: considerations for the waste and wastewater services sector. Case Studies in Chemical Environmental Engineering Prevalence of Gastrointestinal Symptoms and Fecal Viral Shedding in Patients With Coronavirus Disease 2019: A Systematic Review and Meta-analysis SARS-CoV-2 RNA in wastewater anticipated COVID-19 occurrence in a low prevalence area Wetland systems to control urban runoff Absolute humidity modulates influenza survival, transmission, and seasonality Absolute humidity and the seasonal onset of influenza in the continental United States Detection and survival of SARS-coronavirus in human stool, urine, wastewater and sludge Expert Panel Finds Low Risk of Coronavirus for Wastewater Workers. Treatment Plant Operator Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. New Engl A review of virus removal in wastewater treatment pond systems Development of a dose-response model for SARS coronavirus Oxidation Pond Guildeines Fate of pathogenic microorganisms and indicators in secondary activated sludge wastewater treatment plants Corona Virus Situation Updates WHO. 2020b. Report of the WHO-China Joint Mission on Coronavirus Disease Wendtner 337 C. Virological assessment of hospitalized patients with COVID-2019 Reported Cases and Deaths by Country, Territory, or Conveyance Prolonged presence of SARS-CoV-2 viral RNA in faecal samples Infectious SARS-CoV-2 in feces of patient with severe COVID-19 Evidence of airborne transmission of the severe acute respiratory syndrome virus QMRA of SARS-CoV-2 for workers in wastewater treatment plants. medRxiv Fecal specimen diagnosis 2019 novel coronavirusinfected pneumonia Removal of native coliphages and coliform bacteria from municipal wastewater by various wastewater treatment processes: implications to water reuse