key: cord-0836693-cbgq3g6w authors: Jureka, Alexander S.; Williams, Caroline G.; Basler, Christopher F. title: Pulsed broad-spectrum UV light effectively inactivates SARS-CoV-2 on multiple surfaces date: 2021-02-15 journal: bioRxiv DOI: 10.1101/2021.02.12.431032 sha: f151d1acebf0fcdbd096e88541bc02d931b575a2 doc_id: 836693 cord_uid: cbgq3g6w The ongoing SARS-CoV-2 pandemic has resulted in an increased need for technologies capable of efficiently disinfecting public spaces as well as personal protective equipment. UV light disinfection is a well-established method for inactivating respiratory viruses. Here, we have determined that broad-spectrum, pulsed UV light is effective at inactivating SARS-CoV-2 on multiple surfaces. For hard, non-porous surfaces we observed that SARS-CoV-2 was inactivated to undetectable levels on plastic and glass with a UV dose of 34.9 mJ/cm2 and stainless steel with a dose of 52.5 mJ/cm2. We also observed that broad-spectrum, pulsed UV light is effective at reducing SARS-CoV-2 on N95 respirator material to undetectable levels with a dose of 103 mJ/cm2. We included UV dosimeter cards that provide a colorimetric readout of UV dose and demonstrated their utility as a means to confirm desired levels of exposure were reached. Together, the results present here demonstrate that broad-spectrum, pulsed UV light is an effective technology for the inactivation of SARS-CoV-2 on multiple surfaces. In late 2019, the novel severe acute respiratory distress syndrome virus 2 (SARS-CoV-2) 28 emerged from Wuhan, China [1, 2] . SARS-CoV-2 is a member of the Coronaviridae family of 29 enveloped negative-sense RNA viruses. It is classified in the Betacoronavirus genus of which 30 other notable members are the highly pathogenic SARS-CoV and the Middle East respiratory 31 syndrome virus (MERS-CoV) [3] . Since its emergence, SARS-CoV-2 has been the cause of the 32 most severe pandemic in the last century. Despite significant efforts to contain the spread of 33 SARS-CoV-2, as of February 7 th , 2021 it has caused over 105 million cases and resulted in over cm squares of N95 respirator material from a 3M™ 9210+ respirator. Four 0.5x0.5 cm squares of 80 UV dosimeter cards (Intelligo Technologies) were placed in each corner of the plate to confirm 81 even UV exposure across the plates and allow comparison of the cards to a UV dosage meter as 82 a means to quantify exposure dose (Supplemental Figure 1) . For surface inoculation, 12 µL of 83 SARS-CoV-2 stock virus (USA_WA1/2020; 8.3x10 4 pfu) in OptiMEM supplemented with 1x 84 antibiotic/antimycotic (Gibco) was pipetted directly onto each surface being tested and spread 85 with a pipette tip to facilitate efficient drying. Surface samples inoculated with virus were allowed 86 to dry in the 24 well plates with the lids off for 1 hour at room temperature in the biosafety cabinet. to UV were placed inside a black opaque container in a separate biosafety cabinet to avoid calibrated SED270 detector were placed 1 meter away facing the Helo F2 device. Care was taken 94 to ensure that the UV dosage meter and surfaces being exposed were as inline as possible before 95 beginning testing. The 24-well plates containing the test surfaces were positioned so that the 96 plates were nearly vertical (~85 degrees) and approximately 3 inches above the surface of the 97 biosafety cabinet to avoid shadowing (Supplemental Figure 2 ). Once the 24-well plate was 98 positioned, the UV dosage meter was zeroed to account for ambient UV. Once zeroed, the UV 99 dosage meter was set to "integrate" mode to measure UV dosage over time and total pulse-100 counts. The Helo F2 device was initiated using an electronic timer set to the indicated exposure 101 time with an additional minute added to account for device startup procedures. UV dosage for a given timepoint was recorded as mJ/cm 2 along with the corresponding pulse-count. UV dosimeter 103 cards were collected and photographed to record the color change. One card from the 3-minute 104 timepoint was lost due to airflow in the biosafety cabinet. For the purposes of graphical depiction, adsorbed for 1 hour with shaking at 15-minute intervals. After the adsorption period, 1 mL of 0.6% 117 microcrystalline cellulose in DMEM supplemented with 2% fetal bovine serum and 1x antibiotic-118 antimycotic was overlaid onto to the cells and plates were incubated at 37C/5% CO2 for 72 hours, 119 as described previously [30] . After incubation, the microcrystalline cellulose overlay was aspirated 120 from the well, and cells were fixed with 10% neutral buffered formalin for 1 hour at room 121 temperature. Plates were then washed with water and stained with crystal violet to visualize 122 plaques. Plaques were quantified and recorded as plaque forming units per mL (pfu/mL). All 123 samples assayed were only subjected to one freeze-thaw cycle. We first determined the range of UV dosage that could be achieve with the Helo F2 device 128 between 1 and 30 minutes of exposure. The device produces a theoretical 10 pulses per minute. In practice, we achieved 6 pulses after 1 minute and 297 pulses after 30 minutes, corresponding 130 to cumulative UV doses of 3.14 mJ/cm 2 and 103 mJ/cm 2 , respectively ( Figure 1A , B). Interestingly, 131 we observed the UV dosage output by the Helo F2 device over time has a significant and linear 132 correlation with the overall pulse count ( Figure 1C ). This suggests that it is possible to identify a To determine the effectiveness of the Helo F2 device in inactivating SARS-CoV-2, glass, stainless 142 steel, plastic, and N95 respirator material inoculated with SARS-CoV-2 (see materials and 143 methods) were exposed to pulsed UV light for 1, 3, 5, 10, 15, and 30 minutes from a distance of For the UV exposed samples, we observed that for the hard, non-porous surfaces (glass, 156 stainless steel, and plastic) a pulse-on time of 5 minutes (17.2 mJ/cm 2 ) was sufficient to achieve 157 a 3-log10 reduction of infectious virus recovered from the surfaces ( Figure 3A -C). Exposure for 10 158 minutes (34.9 mJ/cm 2 ) was sufficient to reduce infectious virus to nearly undetectable levels on 159 glass and plastic, while 15 minutes (52.5 mJ/cm 2 ) was required for the same effect on stainless 160 steel. N95 respirator material (3M 9210+) required 15 minutes of exposure to achieve a 2.86 log10 161 reduction in infectious virus and 30 minutes (103 mJ/cm 2 ) exposure for reduction to undetectable 162 levels which likely due to the porous and multilayer structure of N95 material ( Figure 3D ) [33] [34] [35] . Taken together, these data suggest that broad-spectrum pulsed UV light is capable of effectively 166 167 Figure 3 . Titers of infectious SARS-CoV-2 recovered from UV exposed glass, stainless steel, plastic, and N95 material (A-D). Time 0 represents controls that were not exposed to UV. All timepoints are representative of the mean and standard error of 3 replicates. Blue shading represents the area under the curve for the UV dosage acquired over time. Samples with data points below the limit of detection resulted from a subset of datapoints having undetectable levels of virus. Undetected samples were assigned a value of 1 for graphing purposes. ensuring the correct dosage has been applied to a surface. Because of this, UV dosimeter cards 171 are available that exhibit a colorimetric change in response to increasing doses of UV light. In 172 tandem with testing the effectiveness of broad-spectrum UV light in inactivating SARS-CoV-2, we 173 were also interested in determining the functionality of UV dosage cards specifically designed for pulsed-UV light sources. To test their functionality, 4 test pieces of experimental UV dosage card 175 material were included in each UV exposure timepoint. We determined that these functioned as identified that the color change was even across all cards recovered at each timepoint indicating cards would be intended for end-users to ensure that a high enough dosage had been applied for with the color change from the cards ( Figure 4B ). Taken together this UV reactive card material 182 represents an effective alternative to high-cost dosage meters for end users of broad-spectrum 183 pulsed UV disinfection equipment. The availability of information regarding the inactivation of SARS-CoV-2 for environmental 187 disinfection is of paramount importance. UV disinfection is a validated technology that has been 188 utilized for decades to inactivate pathogens on surfaces, as well as in air and water [36, 37] . The 189 effectiveness of UV light, pulsed or constant, in inactivating pathogens is expected to be directly 190 related to the dosage applied [33] . Here, we have described empirically determined dosages of Disinfection of potentially contaminated surfaces by broad-spectrum UV light is a particularly 202 attractive option when compared to chemical disinfectants as its less laborious and does not 203 require close contact with contaminated surfaces. Additionally, with PPE shortages being an 204 ongoing concern, our data demonstrates that broad-spectrum pulsed UV could be an effective 205 strategy for the disinfection of N95 respirators, although our study did not determine how pulsed 206 UV exposure affects N95 performance. While our data demonstrate that broad-spectrum pulsed UV light is an effective method for 209 inactivating SARS-CoV-2, one notable limitation of our study is that surfaces were only exposed 210 to the UV light at a distance of one meter. However, our data demonstrated that colorimetric UV 211 dosimeter cards work as expected and provide a clear indication of the dosage being applied to 212 a particular surface where the card is in place. In the event that a surface is more than one meter 213 from a given UV device, using our data as a reference the inverse square law could be applied to 214 determine the amount of time required to achieve a particular dosage at the necessary distance cost method for testing broad-spectrum pulsed UV light devices at different distances to ensure 14. World Health, O. Cleaning and disinfection of environmental surfaces in the context of 284 COVID-19: interim guidance Exploring options for reprocessing of N95 Filtering 287 Facepiece Respirators (N95-FFRs) amidst COVID-19 pandemic: A systematic review CoV-1 and SARS-CoV-2 Viability, Susceptibility to Treatment, and the Disinfection and 291 Particularly Filtering Facepiece Respirators Masks for Prevention of 22 Disinfection of N95 The ultraviolet disinfection handbook Ultraviolet germicidal irradiation handbook : UVGI for air and surface 38 Genomic Modeling as an Approach to 39 Methods of 373 Inactivation of SARS-CoV-2 for Downstream Biological Assays Far-UVC light (222 nm) efficiently and 379 safely inactivates airborne human coronaviruses SARS-CoV-2 replication Disinfection effect 387 of pulsed xenon ultraviolet irradiation on SARS-CoV-2 and implications for environmental 388 risk of COVID-19 transmission Standardization of methods for fluence (UV dose) determination 393 in bench-scale UV experiments Monitoring ultraviolet lamps in biological safety cabinets 47