key: cord-0833305-o6ara4pk authors: Konstantinou, Corina; Constantinou, Andria; Kleovoulou, Eleni G.; Kyriacou, Alexis; Kakoulli, Christina; Milis, George; Michaelides, Michalis; Makris, Konstantinos C. title: Assessment of indoor and outdoor air quality in primary schools of Cyprus during the COVID–19 pandemic measures in May–July 2021 date: 2022-05-02 journal: Heliyon DOI: 10.1016/j.heliyon.2022.e09354 sha: 8ade5e5ae9ea62a3aa99f63454ababebaf8f1775 doc_id: 833305 cord_uid: o6ara4pk Combined pollutant effects from indoor and outdoor sources on children’s health, while being at school have not been holistically tackled. The aim of the School Temperature and Environmental Pollutants Study (STEPS) was to perform a school population representative assessment of indoor air quality (IAQ) in primary schools of densely and intermediate populated areas of Cyprus (n=42). The study took place during May-July 2021 when a school-specific COVID-19 protocol was in place. Questionnaire-based characteristics of schools/classrooms were collected along with 24/48-h long IAQ monitoring of air temperature, relative humidity (RH), particulate matter (PM), carbon dioxide (CO(2)) and volatile organic compounds (VOCs), using low-cost sensors. Mixed effect models assessed the IAQ determinants during school hours. Indoor PM, temperature, RH and VOCs increased with progressing school periods, while indoor CO(2) decreased. Indoor RH and CO(2) were negatively associated with % open windows, while indoor PM(2.5) was positively associated. Most of school time (85%), indoor air temperature exceeded the recommended upper limit (27°C), while a third of indoor PM(2.5) (24-h) measurements exceeded 15 μg/m(3). The interplay of clean indoor air with adequate ventilation and adaptation to heat stress in schools is important in the COVID-19 era and its comprehensive characterization requires holistic methodological approaches and tools. Children in schools are exposed to a suite of environmental pollutants from both indoor and 78 outdoor sources. 1,2 Children's unique characteristics in terms of their metabolism, behaviour, 79 physiology, growth and development make them especially vulnerable to poor environmental 80 conditions. 3,4 These conditions might be a significant determinant of health in their later life. 5 81 Children spend around 25-30% of their time at school during weekdays, 6, 7 and indoor 82 environmental conditions are among the major contributors of their total body burden to 83 various air pollutants. 3, 8, 9 During the last two decades, particulate matter (PM), one of the 84 main air pollutants, was found to be in high concentrations in many schools across different 85 regions of the world. 2 The recent SINPHONIE (Schools indoor pollution and health: 86 Observatory network in Europe) project showed that schoolchildren in 23 European countries 87 were exposed to PM2.5, radon and carbon dioxide (CO2), 11 in higher concentrations than the 88 thresholds defined by the air quality guidelines of the World Health Organization (WHO). 12 89 The same study found that the average daily indoor air temperature across schools was 22°C 90 (SD: 2.11), 11 lying within the recommended range of 15-25 °C, defined by the WHO for indoor 91 air temperatures for minimum energy expediture. 13 The first step in the project was to obtain the necessary approvals for the study. Immediately 178 after securing these approvals by the authorities, we contacted the respective school boards 179 and then the school headmasters of the selected schools. The aim of this first contact was to 180 explain the objectives of the study and the process of the equipment installation and removal, 181 as well as to ask for permission to enter the school premises and arrange appointments for 182 the equipment installations. 192 The classrooms were selected based on the team's assessment in the field and after 193 discussion with the headmaster and the teachers to ensure that the sampling would both be 194 adequate to fulfill the study objectives while at the same time not being disruptive to the 195 school activities. The teachers/headmasters were asked to report whether they had noticed 196 any issues in a specific classroom with regards to IAQ e.g., recent complaints about specific 197 annoyances, such as higher air temperature or a recent event linked to poor IAQ, such as a Data processing and analysis 232 A specific data analysis workflow was implemented to process data collected from the sensors 233 and other exposure assessment tools, including the questionnaires ( Figure S1 ). We estimated descriptive statistics, e.g., mean, median, interquartile range, minimum and 235 maximum per parameter, location (indoors vs outdoors), district and urbanization degree, for 236 the school period (7:45 am -1:05 pm) and the complete sampling period. Time-series plots 237 were created for the visualization of the raw and school-period averaged data per school. 238 Complementary information collected with questionnaires, e.g., timeframe during which 239 windows were open, breaks vs class times or indoors/outdoors was indicated in the plots. 240 To explore the differences between the indoors and outdoors environment parameters, we 241 used linear mixed-effect models accounting for the multilevel design (school/classroom) 242 using school-period averaged data for typical classrooms. The geographical district and 243 degree of urbanization were initially used in the random effect part of the model, however 244 they were dropped after checking the Akaike information criterion (AIC) in models with and 245 without these parameters (AIC was similar in both types of models). Outcomes were the 246 indoor parameter levels and predictors included outdoor levels of the same parameter, (Table S2 ). Similar characteristics were observed between typical and atypical classes 289 (Table S3) . (Table S4 ). The median number of fans in use showed an increase after the 4 th 297 school period and was not in use during the three school breaks (school periods 3, 6 and 9). The descriptives of the parameters measured in schools per location during school class hours 304 (7:45 am -1:05 pm) can be found in Table 2 -1:05 pm), the mean RH and VOCs were higher in atypical compared to typical classrooms 318 while the mean air temperature was higher in typical compared to atypical classrooms (Table 319 S7 ). Table 3 ). 345 The indoor PM levels were negatively associated with indoor RH (e.g., β=-0.040, 95% CI: -346 0.051--0.028, p< 0.001 for PM2.5) ( Table 3) (Table 4) . 358 Sensitivity analysis using only data from atypical classes, showed some differences (Tables S8-359 S9). In atypical classes, the indoor PM levels were negatively associated with the percentage 360 of open windows (e.g., β=-0.032, 95% CI: -0.037--0.027, p < 0.001 for PM2.5) and the school 361 break (e.g., β=-0.526, 95% CI: -0.634--0.418, p < 0.001 for PM2.5) (Table S8 ). Indoor air 362 temperature and RH were positively associated with the percentage of open windows 363 (β=0.008, 95% CI: 0.006-0.011, < 0.001, and β=0.041, 95% CI: 0.020-0.062, p < 0.001, 364 respectively) and the percentage of fans in use (β=0.003, 95% CI: 0.002-0.004, p < 0.001, and 365 β=0.019, 95% CI: 0.011-0.028, < 0.001, respectively) (Table S9) . 366 Most of the school time (85%), indoor air temperature was consistently higher than the upper 368 limit of 27°C recommended by the European standard on the energy performance of buildings 369 (Table 5) . 27 This was corroborated by the observation that only a quarter of the air 370 temperature values were below 27.5°C (Table 2 ). More than half of the school time, the 371 J o u r n a l P r e -p r o o f indoor RH was within the recommended range of 40-60% (Table 5) , 28 whereas more than a 372 quarter of the time, indoor RH was below 40% and 8% of RH measurements were >60%. 373 Almost all indoor CO2 measurements (98%) were within the recommended guidelines (≤800 374 ppm) 27 (Table 5 ) and more than three quarters of the values were below 566 ppm (Table 2) . 375 All 24-hour PM10 values were within the WHO air quality guidelines 29 (≤45 ug/m 3 , Table 5 ), 376 with more than three quarters of the raw values during school class hours being below 20 377 ug/m 3 (Table 2) . However, about one third of the 24-hour indoor PM2.5 values (33%) exceeded 378 the guideline value of 15 ug/m 3 , 29 and about half of the raw values during school class hours 379 were higher than 14 ug/m 3 ( Table 2 ). Percentage of time exceedances for the above-380 mentioned parameters varied between geographical districts and degree of urbanization 381 areas where schools were located (Table S10) . Table 1 writing-review and editing; Konstantinos C. Makris: conceptualization, funding acquisition, 552 investigation, methodology, supervision, writing-original draft preparation, review and editing. 553 Headmasters and teachers provided informed consent as they responded questionnaires. 555 Data used to support the findings of this study are available upon request. De-identified data will be 557 publicly available following publication of the study. 558 559 J o u r n a l P r e -p r o o f Poor air quality in classrooms related to asthma 561 and rhinitis in primary schoolchildren of the French 6 Cities Study A review of scientific evidence on indoor air of school building Pollutants, sources, health effects and management Impacts of Climate Change on Inequities in Child Health Environmental pollutants affecting children's growth and 569 development: Collective results from the MOCEH study, a multi-centric prospective birth 570 cohort in Korea Report of the 572 systematic review on the effect of indoor heat on health The Organisation of School Time in Europe. Primary and 577 General Secondary Education -2021/22. Eurydice Facts and Figures Children's well-being at schools: Impact of climatic 582 conditions and air pollution Monitoring of volatile organic compounds in different schools: a 585 determinant of the indoor air quality European Commission, Directorate-General for Health and Consumers and Promoting Actions for Healthy Indoor Air (IAIAQ) Directorate-General for Health and Consumer Protection Indoor air pollution, physical and comfort 591 parameters related to schoolchildren's health: Data from the European SINPHONIE study (outdoor)-air-quality-and-health 595 13. WHO Regional Office for Europe. Heat and Health in the WHO European Region: Updated 596 Evidence for Effective Prevention The effect of ventilation strategies of child care 600 centers on indoor air quality and respiratory health of children in Singapore Asthmatic symptoms among pupils in 603 relation to winter indoor and outdoor air pollution in schools in Taiyuan, China. Environ 604 Health Perspect Complementing the genome with an "exposome": the outstanding challenge of 609 environmental exposure measurement in molecular epidemiology A Scoping Review on the Characteristics of Human 613 Cyprus Department of Meteorology. Recent Meteorological Data COVID-19 in Children and the Role of School Settings in Transmission -Second Update Cyprus Ministry of Education Culture Sports and Youth. Health Protocol for Primary Schools Cyprus Ministry of Education Culture Sports and Youth. List of public primary schools in 625 Cyprus by district SINPHONIE : Schools Indoor Pollution & Health Observatory Network in Europe : Final 630 Report Research electronic data 632 capture (REDCap)-A metadata-driven methodology and workflow process for providing 633 translational research informatics support Connected Things. mcf88 LoRaWAN Indoor Environmental Sensor with VOC, LUX and CO2 16798-1:2019 Energy Performance of Buildings: Ventilation for Buildings. Indoor 641 Environmental Input Parameters for Design and Assessment of Energy Performance of 642 p=204:110:0::::FSP_PROJECT,FSP_ORG_ 644 ID:41425,6138&cs=11EDD0CE838 BCEF1A1EFA39A24B6C9890 645 28 Ozone, 649 Nitrogen Dioxide, Sulfur Dioxide and Carbon Monoxide Relationship between outdoor and 652 indoor air quality in eight French schools Child exposure to indoor and outdoor air pollutants in 655 schools in Indoor air quality in inner-city schools and its 658 associations with building characteristics and environmental factors Indoor air quality in 661 Portuguese schools: levels and sources of pollutants Indoor air quality in schools of a highly polluted south 664 A Review of Field Measurement Studies on Thermal 666 Comfort, Indoor Air Quality and Virus Risk Xanthi Andrianou for her contributions in the methodology and formal data analysis. A. Kyriacou would like to acknowledge funding from the European Union and the Republic of Cyprus through the Research and Innovation Foundation