key: cord-0832726-z1b5mere authors: Hoehl, S.; Schenk, B.; Rudych, O.; Goettig, S.; Foppa, I.; Kohmer, N.; Karaca, O.; Toptan, T.; Ciesek, S. title: At-home self-testing of teachers with a SARS-CoV-2 rapid antigen test to reduce potential transmissions in schools date: 2020-12-07 journal: nan DOI: 10.1101/2020.12.04.20243410 sha: 5d670431ba673d85996e0a3e033fbab6ee659e34 doc_id: 832726 cord_uid: z1b5mere Background Rapid antigen tests for SARS-CoV-2 became available recently, offering an opportunity to vastly increase testing capacities. Antigen tests offer lower sensitivity than the gold standard, RT-PCR, but rapid sample-to-answer time. High-frequency testing with an antigen test may offset the lower sensitivity, and testing can be done with at-home collection of samples, offering potential benefit in screening efforts. In this study, we set out to evaluate the practical application of self-performed high-frequency antigen test in a school setting. Method A total of 711 teachers from 86 schools were enrolled in a seven-week study. After instruction, participants tested themselves every 48 hours at home with a rapid antigen test for SARS-CoV-2 (target: nucleocapsid protein) in a self-collected anterior nasal swab. Positive results in the antigen test were confirmed via RT-PCR from the same sample that had been determined to be positive by the study participant. A questionnaire was given to all participants to evaluate whether the test failed to detect infection. Findings 10 836 tests from 602 teachers were recorded and analyzed. A total of five confirmed cases of viral shedding of SARS-CoV-2 was detected by use of the antigen test. One study participant with a SARS-CoV-2 infection was presymptomatic and four were mildly symptomatic at the time of the antigen test. Sixteen false positive antigen tests (0.15% of all tests) were reported, predominantly when the local incidence in the general population was low. In four cases, the study participant reported that a PCR had detected a SARS-CoV-2 infection, but the antigen test was negative, indicating a false negative result. Interpretation High-frequency, self-performed rapid antigen tests can detect individuals with a SARS-CoV-2 infection, and therefore potentially reduce transmissions. Testing may be most beneficial when applied during high local incidence of SARS-CoV-2 infections and when mild or atypical symptoms are present. To avoid a high rate of false positive results, a test with optimized specificity should be used. Funding The study was commissioned and funded by the Hessian Ministry of Education and the Hessian Ministry of Integration and Social Affairs. A total of 711 teachers from 86 schools were enrolled in a seven-week study. After instruction, 22 participants tested themselves every 48 hours at home with a rapid antigen test for SARS-CoV-2 23 (target: nucleocapsid protein) in a self-collected anterior nasal swab. Positive results in the antigen test 24 were confirmed via RT-PCR from the same sample that had been determined to be positive by the 25 study participant. A questionnaire was given to all participants to evaluate whether the test failed to 26 detect infection. 27 Findings 28 10 836 tests from 602 teachers were recorded and analyzed. A total of five confirmed cases of viral 29 shedding of SARS-CoV-2 was detected by use of the antigen test. One study participant with a SARS-30 CoV-2 infection was presymptomatic and four were mildly symptomatic at the time of the antigen test. 31 Sixteen false positive antigen tests (0.15% of all tests) were reported, predominantly when the local 32 incidence in the general population was low. In four cases, the study participant reported that a PCR 33 had detected a SARS-CoV-2 infection, but the antigen test was negative, indicating a false negative 34 result. 35 Interpretation 36 High-frequency, self-performed rapid antigen tests can detect individuals with a SARS-CoV-2 infection, 37 and therefore potentially reduce transmissions. Testing may be most beneficial when applied during 38 high local incidence of SARS-CoV-2 infections and when mild or atypical symptoms are present. To 39 avoid a high rate of false positive results, a test with optimized specificity should be used. 40 The study was commissioned and funded by the Hessian Ministry of Education and the Hessian 42 Ministry of Integration and Social Affairs. 43 In the ongoing pandemic of SARS-CoV-2, test strategies continue to rely mostly on real time (RT-) PCR, 45 a highly sensitive and specific method to detect SARS-CoV-2 RNA. Rapid antigen tests (RATs) are also 46 becoming increasingly available and offer point-of-care testing, with results available within minutes. 47 These tests, that are much more affordable and offer the potential of increasing testing capacities as 48 well as reducing sample-to-answer-time, are limited by a lower sensitivity and specificity when 49 compared to PCR. 1-3 However, the sensitivity of RATs may be sufficient to detect most infectious cases 2 , 50 especially when testing is performed in high frequency. 4,5 RATs are usually very simple to perform, and 51 can be combined with self-sampling, to offer at-home testing for non-medical professionals. When 52 using a RAT to test for SARS-CoV-2, anterior nasal swabs have been shown to be a viable alternative to 53 oropharyngeal or throat swabs, when collected by a medical professional, 1 as well as when the sample 54 was self-collected by a non-medical professional. 3,6-8 55 High-frequency testing for SARS-CoV-2 with an RAT is proposed to make some critical environments 56 safer during the pandemic when other non-pharmaceutical interventions are not sufficient to prevent 57 transmissions. Theoretical models have proposed that high-frequency antigen testing may be 58 efficacious to reduce transmissions in such environments. 5, 9 Keeping schools open during the 59 pandemic should be considered a high priority due to potentially detrimental effects of withholding 60 education from children of various age groups. Here, the application of rapid antigen tests could prove 61 to be beneficial. 62 There is limited experience from real-life application of RATs, especially when testing is performed by 63 a non-medical professional without supervision. The primary aim of this study was to determine 64 whether at-home testing results in true-positive detection of unknown viral shedding. 65 66 67 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 7, 2020. ; https://doi.org/10.1101/2020.12.04.20243410 doi: medRxiv preprint The SAFE School Hesse Study (SAFE acronym: German: SARS-CoV-2 FrühErkennung, English: Early 69 detection of SARS-CoV-2) set out to evaluate the practical application of self-testing for SARS-CoV-2 70 with a RAT, performed by teachers. The primary goal of the study was to evaluate the potential of an 71 RAT to detect SARS-CoV-2 infected individuals and thus to enable necessary infection control 72 Teachers from primary and secondary schools in three distinct school districts were invited by the 74 Hessian Ministry of Education to participate in the study. The study period was seven weeks, of which 75 three were before and four were after a two-week autumn vacation in Hesse (September 14 th to 76 October 4th nd and October 17 th to November 15 th , 2020). 77 Study participants received written instructions, as well as an instructional video on how to collect an 78 anterior nasal swab, and step-by-step instruction to perform and read out an RAT (RIDA® QUICK SARS-79 CoV-2 Antigen test, R-Biopharm, Darmstadt, Germany) at home. In the testing process, two reagents 80 were combined with drop bottles, the nasal swabs were irrigated in medium, and a predetermined 81 amount of this sample was transferred to the testing tube with the reagents using a single-use pipet. 82 After 10 minutes of incubation, a lateral flow test strip was added to the test tube. The visual result 83 readout was performed after an additional 10 minutes. Study participants were instructed to observe 84 whether the control band was visible to determine the validity of the result, and to determine whether 85 the test band was visible to determine a positive (test band visible) or negative (test band not visible) 86 result. Study participants were instructed to record all tests on a standardized form. 87 Study participants were provided with the telephone number to the study hotline as well as a 88 designated email address in case any support was needed. In case of positive or inconclusive test 89 readouts, participants were asked to call the study hotline for further instructions. When a sample was 90 deemed or suspected to be positive by the study participant, the sample medium from which material 91 was inserted into the antigen test by the study participant was collected. In the laboratory (Institute 92 for Medical Virology, Goethe University Frankfurt), a SARS-CoV-2 RT-PCR was performed, using either 93 Roche Cobas® SARS-CoV-2 (Roche diagnostics, Basel, Switzerland), Alinity m® SARS-CoV-2 Assay 94 (Abbott Laboratories, Abbott Park, IL, USA) or Xpert® Xpress SARS-CoV-2 (Cepheid, Sunnyvale, CA, 95 USA). The study participants were asked to self-quarantine until PCR results were conveyed. 96 At the end of the study, all participants received a questionnaire to determine whether they 97 encountered any difficulty in the testing procedure, and to record whether they were diagnosed with 98 a SARS-CoV-2 infections but were tested negative with the RAT. 99 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in True positive results A true positive antigen test result was confirmed by RT-PCR in five teachers during the study period 115 (table 1) . A prior or ongoing infection with SARS-CoV-2 was not known in any of these participants at 116 the time of the antigen test. All five true positive cases occurred when the local 7-day incidence in the 117 school district was higher than 100 cases / 100 000 inhabitants (mean 7-day incidence at the time of False positive results In 16 cases, a positive RAT result was determined by the study participant but could not be confirmed 124 by RT-PCR. 13 of these tests were conducted when the 7-day local incidence was below 40 cases / 100 125 000 inhabitants, and three occurred with a 7-day local incidence between 171 and 213 cases / 100 000 126 inhabitants. 12 of the 16 false positive tests occurred while the study participant was asymptomatic, 127 and four while symptoms were reported by the study participant (table 1). In 10 of these 16 cases, the 128 false positive result occurred in the very first test the teacher performed. For four teachers, a false negative result in the antigen test was assumed, as they reported to have 136 received a positive test result by SARS-CoV-2 PCR from a swab that had been collected by a medical 137 professional during the time of high-frequency self-testing with the RAT. Three of these events 138 occurred during high incidence of SARS-CoV-2 (171, 213 and 253 cases / 100 000 inhabitants, 139 respectively). Two of these study participants were symptomatic and one was presymptomatic at the 140 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 7, 2020. ; https://doi. org/10.1101 org/10. /2020 time of the positive PCR test result (table 1) . For one case it was not reported when the false negative 141 test occurred, and if symptoms were present. In one case, the RAT later was positive seven days after 142 the Local incidence during the study period 144 The 7-day local incidence of SARS-CoV-2 infections in the general population was 9 to 348 cases per 145 100 000 inhabitants. 146 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 7, 2020. ; https://doi. org/10.1101 org/10. /2020 Discussion 147 We evaluated the practical application of at-home, high-frequency RATs for SARS-CoV-2 by teachers 148 to prevent SARS-CoV-2 transmission in schools. 149 The test used in this study is a lateral flow SARS-CoV-2 rapid antigen test. While the overall sensitivity 150 of this test was only 50.0 to 77.6% in a recent study, it was 88.2% when samples were used with Ct 151 values below 28, a range that is typically seen during the first week of a SARS-CoV-2 infection, when 152 the patient is likely infectious. Cumulative specificity for the test has been reported to be 94.85%. 11 153 The objective of the study was to determine whether at-home testing results in true-positive detection 154 of unknown viral shedding, causing the potentially infectious teacher to become aware of an infection 155 with SARS-CoV-2, and therefore preventing potential transmissions in school. This outcome was 156 archived in five out of 602 study participants. These individuals had a high viral load in the self-collected 157 nasal swab (Ct values 17.6 to 20.2), indicating they were likely infectious. Possible onward 158 transmissions in the school or in a private setting may have been prevented. All but one of these 159 participants were mildly symptomatic at the time of testing, but only one reported fever at the time 160 of testing. This demonstrates that RAT testing is especially useful when symptoms are present, even in 161 the absence of fever. In one case, headache and fatigue were the only reported symptoms, which 162 highlights the need to test for SARS-CoV-2 even in cases with symptoms that are very prevalent in the 163 general population that may not be immediately attributed to A total of 16 false positive results were recorded by the study participants. Notably, 13 of the 16 false 165 positive tests occurred while the local 7-day incidence of SARS-CoV-2 infections was below 100 cases 166 / 100 000 inhabitants, demonstrating the implications of a low positive predictive value of the RAT 167 during low infection prevalence. To avoid the occurrence of false positive results, large-scale testing 168 could be applied during periods of high incidence, and a test with higher specificity should be used in 169 such screening efforts. 170 In this study, the test material was a nasal swab, which is demonstrated to offer high diagnostic 171 sensitivity, which could also be demonstrated for self-collected samples by non-medical 172 professionals. 3,6,7 We observed 16 false positive results; however, when compared to the total number 173 of study participants, this occurred only in 2.66% of all study participants. As anticipated, the rate of 174 false positive results decreased with a rising prevalence of SARS-CoV-2 that occurred throughout the 175 study period (table 1). The decrease in the false positivity rate may also indicate that false positive 176 results occurred due to a permanent host factor that resulted in these study participants to drop out 177 of the study as it progressed. One such conceivable factor is the nasal colonization with Staphylococcus 178 aureus, which could result in false positive result due to interference with the lateral flow assay 179 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 7, 2020. ; https://doi.org/10.1101 https://doi.org/10. /2020 through the binding of immunoglobulin by staphylococcal protein A (SpA). 12 Indeed, in six out of seven 180 false positive samples, the presence of Staphylococcus aureus could be confirmed. 181 When reviewing the records, very few tests yielded an invalid result (47 out of 10 836 tests, 0.43%), 182 indicating that the RAT could be performed satisfactory by the study participants, who could call a 183 hotline in case any technical or medical support was needed. It is imperative that, when the test is 184 performed without supervision of a medical professional, support is easily accessable. 13 185 Presumably, four out of 10 836 tests were false negative, which might be due to insufficient swabbing 186 technique, an error in testing, result readout, or low viral load in anterior nasal sampling. 187 This study has several limitations. All participants were educators in primary or secondary schools, and 188 therefore had a higher education. Not all teachers at the schools that participated in the study 189 performed the test every 48 hours throughout the entire study period, and not all teachers from the 190 schools participated in the study. Furthermore, no students from these schools were tested, and 191 transmissions in the participating schools were not examined. As no students were enrolled in the 192 study, we also do now know whether the approach of high-frequency, self-performed testing is 193 beneficial in children. 194 In conclusion, we could demonstrate that a high frequency, self-performed antigen tests by teachers 195 can result in the detection of individuals who are probably infectious, and therefore could contribute 196 to making the school environment safer during the pandemic. 197 Testing for SARS-CoV-2 is especially important when symptoms are present, which may also be mild or 198 atypical. As infections may also be missed by use of an antigen test, all non-pharmaceutical 199 interventions should be applied regardless of the use of rapid antigen tests. 200 The authors received positive feedback from the study participants throughout the study, a large 201 majority of whom experienced the study participation with regular testing for SARS-CoV-2 to be 202 reassuring when working in schools during the pandemic. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 7, 2020. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 7, 2020. ; https://doi.org/10. 1101 Comparison of 232 SARS-COV-2 nasal antigen test to nasopharyngeal RT-PCR in mildly symptomatic patients Comparison of seven commercial SARS-CoV-2 rapid 235 Point-of-Care Antigen tests Head-to-head comparison of SARS-CoV-2 antigen-237 detecting rapid test with self-collected anterior nasal swab versus professional-collected 238 nasopharyngeal swab Rethinking Covid-19 Test Sensitivity -A Strategy for 240 Containment Test sensitivity is secondary to frequency and 242 turnaround time for COVID-19 screening Swabs Collected by Patients or Health Care Workers for SARS-244 CoV-2 Testing Patient-Collected Lower Nasal Specimens for Sudden Acute Respiratory Syndrome Coronavirus 2 247 Testing Performance of Saliva Oropharyngeal Swabs, and Nasal Swabs for SARS-CoV-2 Molecular Detection: A Systematic Review and 250 Protein A-Mediated Binding of 255 Staphylococcus spp. to Antibodies in Flow Cytometric Assays and Reduction of This Binding by Using Fc 256 Receptor Blocking Reagent Evaluation of a SARS-CoV-2 rapid antigen test: potential to help 258 reduce community spread The interaction between 260 different domains of staphylococcal protein a and human polyclonal IgG, IgA, IgM and F(ab')2: 261 Separation of affinity from specificity The Missing Piece -SARS-CoV-2 Testing and School Reopening