key: cord-0831745-s5n64jse authors: Marriott, L.; Harper, M.; Zhou, T.; Sun, C. title: Evaluation of High Flow Local Extraction on control of the aerosol plume in an operating theatre date: 2021-05-18 journal: nan DOI: 10.1101/2021.05.16.21257155 sha: 372fd4a8369a17062eaed1e55a3b6df70d3ce6bc doc_id: 831745 cord_uid: s5n64jse Background Engineering controls are a necessity for minimising aerosol transmission of SARS-CoV-2, yet so far, little attention has been given to such interventions. High flow local extraction (HFLE) is a standard in other industries that deal with airborne contaminants. This study provides a quantitative evaluation of an HFLE concept feasible to implement in most real clinical settings. Method A unique combined experimental model of Laser sheet illumination videography paired with continuous nanoparticle counts was used to quantitatively assess the impact of HFLE in an operating theatre. Propylene Glycol was aerosolised via a customised physiological lung simulator and dispersion was measured in 3 dimensions. Cumulative probability heat maps were generated to describe aerosol behaviour. Continuous particle counts were made at 15 locations throughout the room to validate laser assessments. Results HFLE effectively reduced dispersion of simulated exhaled aerosols to undetectable levels. With the HFLE in operation and optimally positioned, the aerosol plume was tightly controlled. Particle counts remained at baseline when HFLE was active. HFLE becomes less effective with increasing distance from source. Plume behaviour in the absence of HFLE was highly variable and unpredictable. Conclusions This analysis demonstrates great potential for HFLE to have a significant impact in reducing aerosol transmission. Simple HFLE devices can be easily engineered and could be widely deployed without impacting on the safe delivery of care. Keywords: aerosol; high flow local extraction; aerosol-generating procedure; tracheal intubation; SARS-CoV-2; COVID-19; plume; personal protective equipment; engineering controls There is increasing evidence that aerosol transmission plays a significant role in the spread of the SARS-CoV-2 (1, 2) . Aerosols are variably defined by size but are generally accepted to be particles of less than 5μm. They are distinct from larger droplets which tend to settle on surfaces within seconds to minutes, traveling significant distances suspended in air near indefinitely (3) and can remain viable for prolonged periods (4) . Health care workers are overrepresented in the infected population, and have at least a 3 fold increased risk of becoming infected in comparison with the general population (5) . Repeated and prolonged exposure to infected individuals correlates positively with severity of illness in health care workers (6). Aerosol generating procedures (AGPs) in medicine may present an increased risk of transmission to health care workers despite effective PPE discipline (7,8). However, it has been suggested that simply breathing and talking represent significant aerosol transmission risks (9). Indoors, aerosol based "viral load" in clinical areas is determined by content released; room size for dilution; and airflow clearance for washout (10). Recent recommendations for adaptations to ICU practice reflect this understanding and include configurations that allow the nursing staff to monitor the patient from outside the room (11), (12). 6 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. The Centers for Disease Control and Prevention (CDC) places engineering controls of risk (such as optimized ventilation) above PPE in its hierarchy of controls (Supplementary Figure 1) . Despite this, high flow local extraction of exhaled aerosols from close to the patient's airway is a concept that has received little attention so far as a strategy to reduce transmission risk to health care workers (13), (14) . Measuring the efficacy of such devices is challenging and may be a contributing factor in this. Furthermore there is no currently available commercial device validated for this purpose in the clinical setting. In this article we describe a simple, prototype high flow local extraction device and an experimental model developed to determine its efficacy in an operational clinical environment. The experimental protocol is refined from the work of previous investigators. Previous assessments of aerosol behaviour have used a high powered laser light sheet to illuminate a smoke plume (10,15-22) , via a camera at right angles or schlieren imaging (23). Other investigators have used particle counters to quantify a single location measurement of an aerosol surrogate such as nebulised saline and powders in low fidelity simulation (24,25). The protocol described here uses aerosolised propylene glycol as a surrogate for respiratory aerosols introduced by a physiological lung simulator into a normal operating theatre (26-28). Assessments of aerosol behaviour and spread are made using a combination of laser sheet illumination and nanoparticle meter counting at multiple locations in the room. 7 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. apparatus"-see Appendix 2), was developed specifically for this project in order to create physiologically realistic and repeatable breathing patterns. Airflow from the test apparatus was passed directly into the distal airway of a TrueCorps mannequin head (a) with anatomically accurate adult human oro and nasopharyngeal anatomy, to simulate realistic plume airflow. Flow volume loops were measured using a Hamilton T1 ventilator flow sensor (b) . Tests were conducted in an operating theatre, under laminar flow (meeting healthcare department performance requirements), with all normal theatre equipment present. Aerosol Generation 8 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint Propylene glycol was chosen as a simulated respiratory aerosol. Particle sizes of propylene glycol measure in the range of 145-175nm once vapourized, being slightly greater than a single SARS-Cov-19 virus, and are neutrally buoyant, hence will move in airflows in a way representative of particles generated by aerosol generating procedures. The prototype high flow local extraction device was designed to redirect existing building extraction and filtration systems to an intake close to the patient. The 3 principal components are as follows: 1. Building ventilation intake shroud (an adaptable structure that can affix to a room's ventilation extraction duct opening). In this case a stainless steel box was prototyped to match the size of the local building extraction outlet duct. It was affixed to the surrounding wall using standard duct tape. 2. Flexible ducting, in this prototype conventional 15cm tumble dryer hosing was used. 3. Patient-end intake cowling (an ergonomically shaped capture funnel, prototyped in cardboard, that sits close to the patient's face without obstructing airway access) to improve airflow entrainment. HEPA filtration is integrated into the building's ventilation system immediately downstream of the intake shroud. There are no moving parts required and the 9 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) Ventilation patterns of 1200ml tidal volume (Vt), and respiratory rate (RR) 12 were used to simulate maximal tidal breathing, as is common prior to the induction of anaesthesia. Furthermore, this pattern represents a greater challenge to the 10 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint performance of the HFLE device than standard tidal breathing. Propylene glycol was introduced as previously described, to act as an aerosol tracer. A single test consisted of a minimum of 5 respiratory cycles as outlined above, with a constant supply of power to the heating coil of the aerosol generator throughout. Throughout each test, a 5-Watt Argon-ion laser was directed across the propylene glycol aerosol plume to map its characteristics and behaviour. A high speed video camera (f) with a pixel resolution of 1920 x 1080 and a frame rate of 50fps was employed to record video of the aerosol plume during tidal breathing, filming perpendicular to the sheet of laser light. Tests were completed in 11 axial slices and 9 sagittal slices, at 5cm increments relative to the centre of the mannequin's mouth (see Figure 1 ). This whole sequence was repeated with the HFLE intake cowling repositioned at 5cm increments from the mannequin's lips in a caudal direction from 15cm to 35cm. The video frames were converted to grey-scale using proprietary coding for probability analysis, where pixel intensity signified particle concentration. A reference 11 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint image was taken before each test. Subtracting the reference image gave a resulting probability plot of aerosol dispersion. Five breaths of cumulative data were used to produce a heat map. Particle count testing was conducted in parallel with laser imaging, to quantify the variation of the aerosol in the room with time and to assess the impact of high flow local extraction on plume control. Particle concentrations were measured continuously using a TESTO DiSCmini particle counter (g) (particles 10-700nm absolute range see Appendix 2). Data was sampled at a rate of one per second and was digitally logged throughout each test. Plots were made using Matlab. The intake cowling for high flow local extraction device was positioned optimally for extraction, 20cm from the mannequin's mouth, as dictated by the laser imaging experiments (see results). Particle measurements were made continuously throughout each test, which consisted of five distinct phases, detailed in Supplementary Table 1 . As shown, an initial five minute phase of background particle measurement preceded any artificial aerosol generation, to serve as a control, confirming values were less than 500 particles/cm³. During each aerosol generation phase, 4ml of propylene glycol was aerosolized completely through the test apparatus. Particle tests were conducted at 15 different locations relative to the mannequin head (Supplementary Illustration 1). . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The images, video and heat maps demonstrate that under these conditions the plume is not stable and varies in both shape and distribution from breath to breath. By reversing the position of the patient, it can be seen that the laminar flow directs the plume caudally. This simple intervention may help reduce risk to the health care workers standing by the mannequins head. (Figure 2 ). The probability heat-maps shown in Figure 3A further characterise the behaviour of the plume in sagittal and axial planes. The heatmaps in Figure 3B demonstrate the effect of high flow local extraction in operation positioned at 25cm from the mouth. FIgure 3C shows a single slice at 15cm offset in the sagittal plane, comparing HFLE (left), to standard airflow (right). The plume can be seen dispersing throughout the whole grid in a cephalad direction and was noted to vary from breath to breath in the latter. 14 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint Without high flow local extraction the probability of encountering aerosol in the studied area is variable, but significant, ranging from 0-100% depending on position. No safe location could reliably be identified in the absence of HFLE ( Figure 4 ). With the high flow local extraction device positioned within 25cm of the vapour origin, the plume is entirely controlled and extracted with no measurable aerosol escape. The probability of encountering aerosol outside of the observable extraction jet is 0%. Efficacy is inversely related to distance from the source. It can be observed from video in the axial plane, when the high flow local extraction device is positioned at 35cm caudally from the mouth, significant aerosol escapes laterally away from the extractor intake and disperses into the room. Particle meter: Significant peaks in measured particle counts were observed in several locations within the operating theatre. These peaks correlated closely in time with phases of aerosol generation. The highest observed increase in particle concentration was seen in the sagittal axis at 170cm from the mouth and 160cm above the floor ( Figure 5 : Particle Count at Location A). Particle counts reached over 30000/cm 3 (over 300x baseline). . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint Particle counts throughout much of the rest of the room were highly variable and dependent upon location within the airflow. Indeed, some locations did not record any measurable particles above baseline, presumably due to air currents bypassing this location. During the use of high flow local extraction (positioned at 20cm from the mouth), particle counts were undetectable above baseline values at all room locations tested. These findings strongly support the quantitative assessments made by laser. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. This article has demonstrated that the prototype high flow local extraction device as tested, is highly effective in this clinical setting, reducing dispersal of exhaled aerosols to undetectable levels. Furthermore, the technique described, provides the first in-situ, scientific assessment of the efficacy of high flow local extraction in simulated aerosol capture. Utilising the physiological negative pressure lung simulator (test apparatus) we have demonstrated a robust experimental model that is able to deliver repeatable, measurable physiological breathing patterns. The laser measurement techniques used here build on the contributions of previous work to more fully characterise quantitatively and qualitatively the behaviour of an exhaled plume in a clinical environment. In parallel, continuous particle measurements made during controlled aerosol release, support and complement these findings (13,16,24). Whilst the static images presented and statistics of particle counts are useful for quantitative analysis, a much richer painting of aerosol behaviour can be achieved by viewing the dynamic video of these experiments. We have also described extensively the behavior of the plume under laminar flow, and have observed simple mitigation strategies that could be implemented immediately to reduce the risk of aerosol exposure to health care workers. One key 17 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Engineering controls such as negative pressure rooms isolate the risk to surrounding areas, but these rooms offer no additional protection to the staff within, beyond their air cycling capability, and should be considered "hot" zones. Further attempts to create engineering controls that limit exposure have led to a proliferation of medical innovations targeted towards reducing exposure of health care workers especially during AGPs eg aerosol box etc. Such innovations have generated much interest, but have rightly been criticised in the peer reviewed literature for failing to satisfy the 18 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Indeed, medicine is starkly at odds with other industries where workers are at risk from airborne contaminants. The construction and welding industries have enshrined "Local Exhaust Ventilation" in workplace safety guidance as an engineered control for decades (safeworkaustralia.gov.au, breathefreely.org.uk) Medical colleges contribute to such guidance yet seem unable to apply the same standard for healthcare workers. It is certainly not inconceivable that the overrepresentation of healthcare workers in the infected population, is at least in part attributable to poor building ventilation/extraction and chronic exposure. The long term impact of this occupational hazard will be hard to quantify. Our study, whilst we believe it to be a sound proof of concept, undeniably has some limitations. The use of propylene glycol in lung simulator apparatus as a surrogate for true respiratory aerosols produced in vivo, must be acknowledged. However, this approach was chosen to enable the control of variability in respiratory dynamics observed in human volunteers. Video of human volunteers exhaling propylene glycol and using the HFLE device (without quantitative assessment) is available 20 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint (https://youtu.be/XA6EGgDhX24) and demonstrates similar findings. Our experiments were limited to the study of aerosols in the range of 140-175nm. The behaviour of larger particles (large respiratory droplets) in this context may not necessarily follow the same pattern. It is also necessary to remember that while these experiments offer a good proxy to quantify risk and measure the efficacy of potential interventions, the dose of airborne viral inoculant in-vivo remains unknown. It should also be remembered that our results so far, apply to the operating theatre under laminar air flow conditions. The apparatus and testing protocol is deployable to all clinical areas, enabling assessments of airflows to be made throughout the hospital in a wide range of clinical scenarios eg ED, ICU, general wards, waiting rooms. Future work will involve the replication of these experiments in the above locations. Further work on engineering controls using high flow local extraction should focus on scalable solutions for other clinical areas. Our study shows that based on the airflows stated, in real clinical environments, high flow local extraction is a viable solution for removing exhaled aerosols. Further, by qualitative and quantitative laser assessment we have determined the optimal positioning of the high flow local extraction device for maximum efficacy. As the plume could be seen dispersing throughout the whole grid area assessed, although fleeting and of low cumulative probability, it was felt that no zone could be nominated as safe in the absence of HFLE. These conclusions were validated by particle counts at multiple high risk locations within the airflow. We have demonstrated this using a simple, easily engineered high flow local extraction device that utilises existing 21 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint theatre ventilation and filtration. We believe such a device is easily reproducible and scalable worldwide throughout hospitals. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Published online June 2020. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Room optimal airflow design, and noted risks of shortcutting with poor design. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Flow/Volume loop produced by NIGEL set to Vt 600ml, RR 12. Flow waveform produced by NIGEL set to Vt 650ml, RR 18. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Glycol. This is placed on a T-piece connected to the test apparatus distal airway. Aerosol is entrained into the test apparatus during inspiration. Supplemental airflow delivered by an aquarium pump (e) at 2.4lt/min provides the air supply to be saturated, thereby preventing coil burnout. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint The field of view was illuminated by a 5-Watt continuous wave Argon-ion laser, with a scattering angle of 38 degrees. The flow field was recorded by a digital camera (Sony Cyber-shot RX100 V (f) ), with a resolution of 1920 x 1080 pixels and frame rate of 50fps. Both the laser and the camera were mounted on tripods. The camera was positioned perpendicular to the axis of the laser beam. The individual frames were elicited and converted into grey-scale images for probability analysis. Those processes were performed by Matlab code which was designed explicitly for this study. Reference images must be taken before each test to eliminate any permanent background lighting. By subtracting the reference image, each frame represented the intensity of the light sheet corresponding to the smoke concentration. The images were normalized with the highest intensity value in the smoke, and the results were applied to establish the particle concentration topologies. Laser imagery tests were first conducted without high flow local extraction in operation. The high flow local extraction device was then positioned on the mannequin's "chest" at 20cm from the mouth , and then at three increments of five cm caudally to a maximum of 35 cm from the mouth. In each of these positions tests were completed in three sagittal slices and five axial slices. A total of 52 laser and device configurations were tested across both axes and four extractor positions to most effectively map plume behaviour both with and without high flow local extraction. . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint Particle meter TESTO DiSCmini (g) records the particle number in a time resolution of 1 second, in the range from 10 to 700 nm, and the mean particle size in the range from 10 to 300 nm Particle size: 10 to 700 nm (absolute. for particle number) 10 to 300 nm (Modal. for mean particle size) 2. diagonally toward the corner exhaust vents at distances of 160 and 270cm. In each of these locations measurements were made at three heights of 160cm, 80cm and 50cm from the floor. Prior to each test, all room doors were opened fully and the room was left empty for 20 minutes to allow clearance of residual aerosols from previous tests. Room doors were then 59 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) Prototype HLFE device Fiona Stanley Hospital theatres airflow system is of industry standard, having a centrally mounted ceiling inflow, and 4 floor level corner outflows with both of these being fan forced. The balance of these is maintained to create a pressure above the ambient pressure of surrounding areas by approximately 10 pascals resulting in a positive pressure theatre to prevent airborne contaminants entering the surgical field. Flow rates result in over 20 air changes per hour, of a typical 150m3 room, with a quarter of this being pulled from each corner duct. Downstream is HEPA filtration before exiting the building system. The prototype Extractor works by diverting normal room extraction from one such corner duct, in a process we have termed RIVET (Repurposing Integrated Ventilation for Extraction in Theatre). One corner vent is shrouded with a custom built, baffled plenum box, with an intake nozzle on the top surface. It is attached to the wall with duct tape and is easily removed and cleaned. The box is constructed of stainless steel and the front has louvres which can be closed to engage the extraction from the intake nozzle or opened, to allow "normal" room extraction. Simple air duct tubing (15cm diameter, 5m length) is attached to the intake nozzle and brought across the room with the "patient" end positioned on the chest close to the airway. A cardboard flange is attached at this end to form a funnel shaped 60 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. During our testing the prototype high flow local extraction device flow was measured to be 62L/sec at the intake cowling, with velocity 3.5m/sec 61 . CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 18, 2021. ; https://doi.org/10.1101/2021.05.16.21257155 doi: medRxiv preprint Other devices, as yet unvalidated and or requiring extensive building modification: https://www.nederman.com/en-us/applications/aerosols-suction https://about.unimelb.edu.au/newsroom/news/2020/april/researchers-design-ventilation-hood s-for-hospital-beds-to-help-contain-covid-19-spread https://vapotherm.com/clinical/felix-1-white-paper-computational-fluid-dynamic-modelling-ofparticle-capture-possible-use-of-a-modified-face-tent-as-a-facial-scavenger/ CC-BY-NC 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care Turbulent Gas Clouds and Respiratory Pathogen Emissions Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 Risk of COVID-19 among front-line health-care workers and the general community: a prospective cohort study We would like to acknowledge the strong support of our anaesthetic and engineering department at Fiona Stanley Hospital. The University of Western Australian has been an invaluable partner in enabling this study.Financial Support: None reported All authors contributed equally to the production of this manuscript.There are no competing interests declared.