key: cord-0831057-pnl874ar authors: Stadler, L. B.; Ensor, K.; Clark, J. R.; Kalvapalle, P.; LaTurner, Z. W.; Mojica, L.; Terwilliger, A. L.; Zhuo, Y.; Ali, P.; Avadhanula, V.; Bertolusso, R.; Crosby, T.; Hernandez Santos, H.; Hollstein, M.; Weesner, K.; Zong, D. M.; Persse, D.; Piedra, P. A.; Maresso, A. W.; Hopkins, L. title: Wastewater Analysis of SARS-CoV-2 as a Predictive Metric of Positivity Rate for a Major Metropolis date: 2020-11-06 journal: nan DOI: 10.1101/2020.11.04.20226191 sha: 9205526626034952f7e61104f6cd6e0c345f5eb6 doc_id: 831057 cord_uid: pnl874ar Wastewater monitoring for SARS-CoV-2 has been suggested as an epidemiological indicator of community infection dynamics and disease prevalence. We report wastewater viral RNA levels of SARS-CoV-2 in a major metropolis serving over 3.6 million people geographically spread over 39 distinct sampling sites. Viral RNA levels were followed weekly for 22 weeks, both before, during, and after a major surge in cases, and simultaneously by two independent laboratories. We found SARS-CoV-2 RNA wastewater levels were a strong predictive indicator of trends in the nasal positivity rate two-weeks in advance. Furthermore, wastewater viral RNA loads demonstrated robust tracking of positivity rate for populations served by individual treatment plants, findings which were used in real-time to make public health interventions, including deployment of testing and education strike teams. 7 viral concentrations are typically present at lower concentrations than in primary solids (22). Our 121 findings show significant associations between influent wastewater concentrations and positivity 122 rates and suggest that influent SARS-CoV-2 RNA concentrations may lead positivity rates by 7 123 to 14 days in such samples. 124 Total viral load for each WWTP was plotted against the total clinical positive cases for the 125 corresponding service area for the entire study period (Fig. 1D) . Combining all 39 sites sampled 126 over the entire 22-week study period revealed a strong relationship between the wastewater viral 127 load and positive cases (Spearman r = 0.92). This provides compelling evidence that wastewater 128 monitoring of SARS-CoV-2 RNA could be used to estimate COVID-19 disease prevalence in 129 communities, in addition to a tool for trend tracking. There is considerable uncertainty in 130 positivity rate ( Fig. 3B and Fig. S4 show the time series plots for the model estimates overlaid 167 on the positivity rate for individual WWTPs). 168 Given the strong predictive relationship of wastewater viral loads and positivity rates, 169 wastewater monitoring represents a viable approach to test the entire population of Houston 170 simultaneously and a means to provide continuous, weekly monitoring of the entire population. 171 This is particularly critical if diagnostic testing rates decline. In 12 of the 39 sewersheds 172 monitored, there was at least one occurrence of when less than 0.1% of the sewershed's 173 population was nasal tested over a 7-day period during our study period. These 12 sewersheds 174 serve a total population of 613,000, approximately 15% of the total population of Houston. In 175 these sewersheds, wastewater monitoring represented the primary means of assessing the 176 magnitude of disease impact in the community. For example, when applied to the sewershed 177 MUD#203 (Fig. 3B) the predictive model could be used to estimate positivity rate during periods 178 when clinical testing data was sparse. This approach illustrates the power of using wastewater 179 viral load to forecast positivity rates in communities. While the models shown here are specific 180 to the Houston system, this model structure could be applied to other cities to forecast positivity 181 rates based on measured viral loads. 182 Time-series geospatial analysis of population normalized wastewater viral loads can be used 184 to identify locations experiencing high infection burden each week ( Fig. 4A and Fig. S5 ). To 185 identify specific areas that are experiencing rapid community spread of the virus, we can 186 visualize the change in the wastewater viral load from week to week. Assessment of the rate of 187 change allows one to determine how an outbreak is accelerating with time, a critical metric when 188 considering the efficient application or exhaustion of intervention or healthcare resources. When 189 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint the time-series for the entire survey period is transformed into a heat map for all 39 sites, clear 190 week to week acceleration and deceleration of viral levels are observed (Fig. 4B) . Remarkably, 191 every site across the entire city, albeit 1, showed a net increase in viral levels during the June 29 192 to July 6 week interval (Fig. 4B (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint into the vacuum manifold followed by the addition of MgCl2*6H2O to achieve a final 281 concentration of 25 mM. The samples were gently swirled with a pipette tip to homogenize and 282 allowed to sit for five minutes. A vacuum pump then pulled the sample through the filter. After 283 filtration was complete, the filter was folded and placed into a bead tube containing 0.1 mm glass 284 beads. Bead tubes containing filters were stored at -80 ℃ and allowed to freeze prior to bead 285 beating and nucleic acid extraction. µL of PM1 solution were added to each bead tube. Sample tubes were bead beaten at max speed 302 in a Mini-Beadbeater 24 (3,500 rpm; 112011, BioSpec) for 1 minute, returned to ice for 2 303 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint minutes, bead beaten for 1 minute, and then returned to ice. After bead beating, tubes were 304 centrifuged at 17,000 g for 2 minutes to pellet the filter debris and beads. Approximately 450 µL 305 of sample lysate from the bead beating tube was transferred into a rotor adapter for extraction 306 using the QIAcube Connect (9002864, Qiagen) automated platform. Each sample was eluted in 307 50 µL nuclease-free water. All extracts were stored at -20 °C until quantification. were bead beaten at max speed in a Mini-Beadbeater 24 (3,500 rpm; 112011, BioSpec) for 1 319 minute, returned to ice for 2 minutes, bead beaten for 1 minute, and then returned to ice. After 320 bead beating, samples tubes were administered 40 µL of Proteinase K and then briefly vortexed 321 to mix. Sample tubes were then incubated at 56 °C for 10 minutes followed by centrifugation for 322 2 minutes at 17,000 g. After centrifugation, 350 µL of supernatant was added to the first well of 323 the Maxwell cartridge along with 300 µL of Lysis Buffer. The Maxwell RSC 48 completed the 324 extraction and eluted the sample into 50 µL of elution buffer. Extracts were stored at -20 °C until 325 quantification. 326 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. of 30x from wastewater to RNA extract, and converting from µL to L, the LOD was calculated 341 as 6,667 copies/L wastewater. 342 Rice quantification of SARS-CoV-2 RNA via RT-ddPCR. RNA extracts stored at -20 °C were 343 thawed on ice, centrifuged at 17,000 g for 5 minutes to remove residual magnetic beads (if the determined as 3 positive droplets per reaction well of ddPCR, which is equivalent to 350 approximately 0.33 gene copies/µl RNA template. Applying a concentration factor of 1,000x 351 from wastewater to RNA eluate (50mL wastewater is concentrated to generate a 50µl RNA 352 extract), and converting from µl to L, the LOD was calculated as 330 copies/L wastewater. 353 The reaction composition followed the manufacturer recommendations. Each 22 µL duplex 354 reaction contained 0.12 µL DNA-grade water, 5.5 µL Supermix, 2.2 uL reverse transcriptase, 1.1 355 µL DTT (15 mM), 0.55 µL N1 probe (0.25 µM), 0.5 µL N1 forward primer (0.9 µM), 0.5 µL N1 356 reverse primer (0.9 µM), 0.55 µL N2 probe (0.25 µM), 0.5 µL N2 forward primer (0.9 µM), 0.5 357 µL N2 reverse primer (0.9 µM), and 10 µL of RNA template (100 fg -100 ng). The N1 and N2 358 sequences used here for primers and probes were taken from the recommended CDC sequences 359 (Table S2) . Primers and probes were purchased from Genewiz and Applied Biosystems. The 360 RNA templates and the ddPCR plates were maintained on ice throughout the procedure. After 361 droplet generation, thermocycling was conducted on a C1000 Touch Thermocycler (1851196, 362 Bio-Rad). Thermocycling consisted of reverse transcription at 50 °C for 60 minutes, enzyme 363 activation at 95 °C for 10 minutes, followed by 40 cycles of denaturation at 95 °C for 30 seconds 364 and annealing/extension at 60 °C for 1 minute (2 °C/sec ramp rate), and completed with enzyme 365 deactivation at 98 °C for 10 minutes. Samples were then held at 4 °C in the thermocycler for no 366 more than 12 hours until droplet reading. Droplets were analyzed using automatic settings on the 367 QuantaSoft v1.7.4 software, and manual thresholding was performed when automatic settings 368 failed to detect clusters of positive and negative droplets. The Rice laboratory compared assays using RT-qPCR versus ddPCR for quantifying N1 and N2 388 targets in wastewater samples. To confirm that results generated between ddPCR and RT-qPCR 389 corresponded, Rice directly compared concentrations of the same extracts as quantified by the 390 two different methods. We found a relatively linear relationship (N1 -R 2 = 0.80, N2 -R 2 = 0.91), 391 where RT-qPCR measurements were roughly 0.07 times and 0.31 times that of ddPCR for N1 392 and N2, respectively (Fig. S1) . These results indicate that measurements from the two methods 393 can be directly compared when an appropriate adjustment factor is applied. We also compared 394 N1 to N2 concentrations as measured by the two methods. We found a linear relationship 395 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint (ddPCR -R2 = 0.92, RT-qPCR = 0.93) where N2 measurements were about 0.7 times and 3.05 396 times N1 for ddPCR and RT-qPCR, respectively. Differences between ddPCR and qPCR, as 397 well as N1 and N2 may be caused by differences in primer/probe binding efficiency between N1 398 and N2, biases introduced by standards in RT-qPCR, and/or differences in sensitivity of the 399 different channels in ddPCR to detect their fluorophore of interest. For WWTP activities, COVID-19 results are extracted from HEDSS and geocoded to 417 wastewater treatment plant service area (WWTP) so that each test result has a corresponding 418 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint COVID-19 and people who have tested positive for COVID-19 are determined for each WWTP. 420 This frequency data is used to calculate the positivity rate by WWTP service area. 421 Data cleaning and early processing 422 Electronic data was updated weekly. It consisted of wastewater analysis results (N1 and N2 423 copies/L of wastewater) from BCM and Rice, and population and flow rate information from the 424 City of Houston. In all cases, the information was at the WWTP level. The format of the files 425 was comma separated files (CSV). The data was imported into R programming language through 426 the RStudio Integrated Development Environment (IDE). Several steps were performed to make 427 sure that naming conventions as well as sample identification were consistent between the 428 diverse data providers. The processed weekly dataset was appended to the historical dataset. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint calculate the week-to-week change for each WWTP (see Fig 4B) . A multilevel model was used, 443 which included and indicator variable representing week n-1 and week n interacted with the 444 WWTP to assess the change, lab, targets of N1 and N2, and a random effect to incorporate the 445 three replicates of each combination. 446 In addition to the weekly trend assessment, nonparametric regression methods were 447 implemented to obtain the longitudinal profile for the measured viral load and clinical positivity 448 rate for each WWTP and the city as a whole. A semi-parametric spline regression model was 449 used to smooth the weekly aligned viral load in log10 copies/day from each lab for each WWTP. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint over the 14-day period, demonstrating that wastewater viral load estimates represent a leading 487 indicator of clinical positivity rate. 488 Predictive models were explored for the clinical positivity rate based on the wastewater viral 489 load for each WWTP service area. The predictive models used were regression models with 490 different predictor variables derived from the longitudinal estimates of the wastewater viral load 491 (in log10 copies day -1 ) for each WWTP. The models were as follows: 492 Model 1: Indicator for WWTP, current, 1-week and 2-week lag of log10 copies/day, 493 Table S3 . 506 In Models 1 and 2, the intercept represents the contribution from the WWTP 69 th Street, the 507 WWTP serving the largest percentage of the Houston population. For both fitted models, the 508 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. between May 11 and October 5. Individual observations for the wastewater viral load and 552 positivity rate are denoted by ° and green (wastewater) and blue (positivity rate) lines are the 553 nonlinear regressions (splines) fit to the observations. Grey represents the 95% confidence bands. 554 rsmooth is the Spearman correlation estimate (r) between the wastewater and positivity rate splines 555 taken weekly, and rraw is between the raw observations taken weekly on the dates with 556 wastewater observations. A total of 16 WWTPs were sampled, but two WWTPs, Sims Bayou 557 North and Sims Bayou South, have overlapping geographic service areas, so the wastewater data 558 for both WWTPs was compared to clinical positivity rate data for the combined population 559 served by the facilities and only Sims Bayou North is shown. 560 561 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint A. B. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted November 6, 2020. ; https://doi.org/10.1101/2020.11.04.20226191 doi: medRxiv preprint Implementation of environmental 592 surveillance for SARS-CoV-2 virus to support public health decisions: Opportunities and 593 challenges How sewage could reveal true scale of coronavirus outbreak Prevalence of Gastrointestinal Symptoms and Fecal Viral Shedding in Patients With 599 Coronavirus Disease 2019: A Systematic Review and Meta-analysis First case of 2019 novel coronavirus in the United States SARS-CoV-2 608 productively infects human gut enterocytes. Science (80-. ) Presence of SARS Coronavirus-2 RNA in Sewage and Correlation with Reported COVID-19 Prevalence in 611 the Early Stage of the Epidemic in The Netherlands First confirmed detection of SARS-CoV-2 in untreated 618 wastewater in Australia: A proof of concept for the wastewater surveillance of First detection of SARS-CoV-2 RNA in wastewater in North America: A 622 study in Louisiana First detection of SARS-CoV-2 in untreated wastewaters in Italy First environmental surveillance for the 627 presence of SARS-CoV-2 RNA in wastewater and river water in Japan Preliminary results of SARS-CoV-2 detection in sewerage system in SARS-CoV-2 titers in wastewater are higher than expected from clinically confirmed 642 cases. mSystems Measurement of SARS-CoV-2 RNA in wastewater tracks community 646 infection dynamics Spatial and temporal dynamics of SARS-CoV-650 2 in COVID-19 patients: A systematic review and meta-analysis The presence of SARS-CoV-2 RNA in the feces of Estimation of polio infection prevalence from environmental surveillance data Survival of Coronaviruses in Water Survivability, Partitioning, and 672 Recovery of Enveloped Viruses in Untreated Municipal Wastewater Evaluating the fate of 675 bacterial indicators, viral indicators, and viruses in water resource recovery facilities