key: cord-0830198-ac19ct3b authors: Declementi, Michael; Godono, Alessandro; Mansour, Ihab; Milanesio, Nicolò; Garzaro, Giacomo; Clari, Marco; Fedele, Luca; Passini, Valter; Bongiorno, Carmela; Pira, Enrico title: Assessment of air and surfaces contamination in a COVID-19 non-Intensive Care Unit date: 2020-10-31 journal: Med Lav DOI: 10.23749/mdl.v111i5.9991 sha: 3ef5ab8083a01ed3e696c4cafbbf90903f3796ca doc_id: 830198 cord_uid: ac19ct3b BACKGROUND: Severe Acute Respiratory Syndrome - Coronavirus – 2 (SARS-CoV-2) is a virus, primarily transmitted through droplets, able to persist on different surfaces and in the air for several hours. During the COVID-19 pandemic, Health Care Workers should be considered a high risk profession. Beside social distancing rules and the proper use of Personal Protective Equipment, sanitization measures and ventilation system disinfection are essential to reduce viral transmission. OBJECTIVES: This is the first Italian study aiming to assess the magnitude of environmental contamination in a COVID-19 non-Intensive Care Unit. METHODS: In addition to ordinary cleaning procedures, surface and air samplings have been performed before and after the application of two different sanitization devices. Samples have been analyzed with Real Time-Polymerase Chain Reaction in order to find viral RNA. RESULTS: All samples obtained from surfaces and air before and after extra-ordinary sanitization procedures turned out negative for viral detection. DISCUSSION: These findings highlight the efficiency of ordinary cleaning procedures in guaranteeing a safer workplace. The adoption of additional sanitization protocols should be considered in order to further reduce environmental viral contamination. air and surfaces contamination 373 todi: In aggiunta alle procedure di pulizia ordinaria, sono stati effettuati campionamenti su aria e superfici prima e dopo l'adozione di due diversi meccanismi di sanificazione. I campioni ottenuti sono stati analizzati con la metodica di Real Time-Polymerase Chain Reaction. Risultati: Tutti i campioni effettuati, sia prima che dopo le misure di sanificazione non ordinarie, sono risultati negativi per la ricerca del virus. Discussione: I risultati evidenziano l'efficacia delle misure di pulizia ordinaria per garantire una maggior sicurezza sul posto di lavoro. L'adozione di procedure di sanificazione non ordinarie dovrebbe essere presa in considerazione per ridurre ulteriormente l'entità della contaminazione virale. introduction Severe Acute Respiratory Syndrome -Coronavirus -2 (SARS-CoV-2) is a RNA virus of the family of Coronaviridae (11) primarily transmitted between people through respiratory droplets and contact routes (17) . Until May 2020, SARS-CoV-2, responsible for a pathology known as COronaVIrus Disease-19 (COVID- 19) , caused over 5.5 million infections and almost 350,000 deaths worldwide (6). Coronaviruses have been recently involved in nosocomial outbreaks and, likewise, a nosocomial transmission of SARS-CoV-2 has been reported. Thus, Health Care Workers (HCWs) should be considered an occupational group at high risk for SARS-CoV-2 infection (5) . The occurrence of HCWs-associated infections might be associated with viral contamination of the air and surfaces surrounding COVID-19 positive patients and carriers. Recent publications (8, 13) demonstrated that the environmental stability of SARS-CoV-2 on surfaces is up to four hours on copper, up to 24 hours on cardboard and up to two to three days on plastic and stainless steel. Its persistence in the air postaerosolization is up to three hours. Because of evidence on the role of airborne transmission in the spread of other two zoonotic Coronaviruses (13) , recent studies have attempted to test this hypothesis also for SARS-CoV-2. In this regard, recent studies (4) suggest that Heating, Ventilation and Air Conditioning (HVAC) systems may have a role in viral transmission, especially in buildings such as hospitals or other healthcare facilities. Ventilation systems have already been reported as a way of transmission of other infectious diseases such as measles, tuberculosis, chickenpox, influenza, smallpox and legionellosis (1). Beside social distancing and proper Personal Protective Equipment (PPE) use, it is essential, in order to reduce the infection risk, to establish and follow procedures for a correct sanitization of the environments that could have been contaminated with SARS-CoV-2. The World Health Organization (WHO) recommends ensuring that environmental cleaning and disinfection procedures are followed consistently and correctly (16) . Various types of biocidal agents such as hydrogen peroxide, alcohols, sodium hypochlorite or benzalkonium chloride are used effectively worldwide for surfaces disinfection, mainly in healthcare settings. In particular, alcoholbase disinfectants have been shown to significantly reduce the infectivity of enveloped virus like SARS-CoV-2 (8). Furthermore, correct air recirculation strategies and ventilation system disinfection measures need to be adopted in order to reduce this possible route of transmission. However, to date, the extent and the role of SARS-CoV-2 environmental contamination as well as the persistence of the virus on surfaces and in the air are not fully elucidated and the present knowledge is mostly based on studies of other Coronaviruses. A better understanding of the spreading mechanisms of SARS-CoV-2 could have an important impact on prevention and control strategies. Therefore, the primary aim of this study was to measure the presence of viral RNA on surfaces and in the air of potentially contaminated environments in a COVID-19 non-Intensive Care Unit (ICU). A secondary aim of the study was to investigate the effect of additional sanitization procedures. Batch of samplings were performed at two times, the first day at 12.00 and the second day after 24 hours. The second day samples were collected after the adoption of extra-ordinary sanitization procedures. The first day, surface samplings were collected 18 hours after the last daily ordinary cleaning procedure with disinfectants made with chlorhexidine, quaternary ammonium salts with high alcohol concentration and sodium hypochlorite. Before the beginning of the study, ordinary cleaning procedures were carried out twice a day by qualified personnel. The second day, surface samplings were performed after an extra-ordinary sanitization procedure with a hot disinfection system (based on a solution with high alcohol concentration and quaternary ammonium salts) ( Figure 1 ). Air samplings were also collected at two times, on day one they were performed at basal condition and on day two after a procedure of disinfection of air conditioning ducts via an atomizer that supplies high quantities of hydrogen peroxide microparticles (0.3-0.5 µm). A total of 34 environmental samples were collected (Table 1) . Main sites of sampling are represented in Figure 2 . Before every batch of samplings, room temperature, humidity and atmospheric pressure were measured. Twenty-four surface samples were obtained inside the COVID-19 non intensive care unit: 12 samplings were collected before extra-ordinary sanitization procedures and 12 after extraordinary sanitization procedures. One surface sample from an administration office was obtained outside the unit as a control sample. Eight samples were obtained from PPE: four from the inner layer of two surgical masks worn by two patients (two before and two after the extra-ordinary sanitization procedure) and four from the outer layer of two disposable gowns worn by two nurses for one working shift (two before and two after the sanitization extra-procedure). Following WHO recommendations (15) , samples were taken by brushing a 25-cm 2 area with a swab with a synthetic tip and a plastic shaft (Swab 490CE.A produced by Copan Italia S.p.A) and, subsequently, stored in a vial containing 3 ml of Universal Transport Medium (UTM-RT). Air sampling (3) was performed using SKC Flite pumps (47 mm filter cassettes and 0.45 µm filters in polytetrafluoroethylene-PTFE) positioned 1 meter above the floor for 340 minutes at 15 l/min. The calibration and the verification of the pump flow rates were carried out using a certified primary flow meter. A total of four pumps were placed in four different sites: patient 1 room, patient 2 room, an empty room nearby patients' rooms, corridor outside the rooms. One air control sample was obtained outside the hospital. Each patient room had a volume of about 90 cubic meters. All samples were stored at 4°C and sent to a microbiology laboratory within 3 hours from the collection and afterwards processed with Real Time -Polymerase Chain Reaction (RT-PCR) to detect SARS-CoV-2 RNA. The two patients (patient 1 and patient 2), admitted to the hospital rooms investigated (room 1 and room 2) were positive to COVID-19 for more than a week and underwent a nasopharyngeal swab before starting the environmental sampling. Surface samples collected before and after sanitization (n=24) were all negative for SARS-CoV-2 RNA, as was the single control sample. Air samples before and after sanitization (n=8), obtained filtering 25000 litres of air, failed to detected the presence of SARS-CoV-2 at the RT-PCR test. Also the PTFE filter of the pump placed outside the hospital was negative for RNA detection. Patient 1 rhinopharingeal swab was positive while patient 2 rhinopharingeal swab was negative ( Table 2) . To the best of our knowledge, this is the first study aiming to assess the magnitude of environmental contamination in a COVID-19 non-ICU in Italy. All samples obtained from surfaces and air have turned out negative, while other scientific studies report different results. These differences may have several explanations, as discussed below. Ye G et al. (18) , analysing 626 surface samples from 13 different hospital areas of Zhorgnan Medical Center of Wuhan Universitiy, showed 85 (13,6%) positive results: ICU was the most contaminated area (p<0.01). Another study, performed by Ong SWX et al. (12) , reported RNA presence in 17/28 surface samples, in an ICU with symptomatic COVID-19 patients, while our study was carried out in a non-ICU, without patients requiring assisted ventilation. Beside patients' settings, also clinical features should be considered. Patients recruited in our study were asymptomatic and only one of two rinopharingeal swabs was positive at the RT-PCR and, thus, it is plausible to expect that our cases show a lower viral load, according to the results of Liu Y et al. (9) that found that the mean viral load of severe COV-ID-19 positive cases was around sixty times higher than that of mild ones. Moreover, mild cases had an earlier viral clearance, compared to severe ones. Also, the time elapsed between diagnosis and environmental sampling may play a role. As shown by Po Ying Chia et al. (2) , the probability to find viral RNA on surfaces decreased with time elapsed from diagnosis. These Authors analyzed 245 surface samples on 30 single rooms of COVID-19 positive patients: floor, bed rail and beside locker surfaces were the most likely to be contaminated. They found at least one positive sample in 10/15 rooms of patients with recent (< 7 days) diagnosis while only in 3/15 rooms of patients with an older diagnosis (> 7 days) there were positive samples. Our results well agree with Po Ying Chia et al. (2) since our patients had a microbiological diagnosis older than a week. Furthermore, our study was conducted in an advanced phase of the COVID-19 pandemic. On one side, the number of patients at the time of samplings was lower compared to a few weeks before and, on the other, there were an implementation over the ordinary sanitization measures. The contribution of 7) did not find any traces of viral RNA on 36 surfaces analyzed in COVID-19 isolation wards. Surface samplings were done after 4 hours of environmental disinfection with 1000 mg/L chlorine containing disinfectant. These data, according to our study, seem to confirm the importance of sanitization in reducing SARS-CoV-2 environmental contamination (19) . Our study has some limitations. Firstly, the sample size was small, reducing the probability to detect viral RNA contamination. Secondly, it must be considered that the air volume sampled was only a fraction of total volume, and periodic air exchanges in the room could have diluted the presence of SARS-CoV-2 in the air. Another limitation is related to the reliability of the sampling method and of the laboratory technique. On one side, the macroscopic and microscopic characteristics of the examined surfaces could have influenced the accuracy of the sampling method increasing the risk of false negative results. On the other, RT-PCR for SARS-CoV-2 detection has a 70% sensitivity and a 95% specificity, with a probability of 30% of false negative results (14) . Finally, our study took place in a limited period of time, without the possibility of repeated samplings over the time. These preliminary results show the absence of SARS-CoV-2 RNA in surface and air samples in a COVID-19 non-Intensive Care Unit. Possible explanations to these preliminary findings are related to the limited number of hospitalized patients at the time of the samplings, to patients' clinical features and their likely low viral load, to the significant amount of time elapsed between diagnosis and environmental samplings and to the daily adoption of ordinary sanitization procedures. Since the pre-sanitization samplings were negative, we were not able to assess the secondary aim of our investigation in order to evaluate the efficacy of extra-ordinary disinfection procedures. Further investigations are needed to better analyze this topic. Airborne Precautions. Treasure Detection of Air and Surface Contamination by Severe Acute Respiratory Syndrome 2 Coronavirus 2 (SARS-CoV-2) in Hospital Rooms of Infected Patients Mortality and cancer morbidity among cement production workers: a meta-analysis. Int Arch Occup Environ Health A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran COVID-19 infection and diffusion among the healthcare workforce in a large university-hospital in northwest Italy SARS-CoV-2 RNA Detection of Hospital Isolation Wards Hygiene Monitoring During the Coronavirus Disease 2019 Outbreak in a Chinese Hospital Persistence of coronaviruses on inanimate surfaces and its inactivation with biocidal agents Viral dynamics in mild and severe cases of COVID-19 Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals Genomic characterisation and epidemiology of 2019 novel coronavirus: implications for virus origins and receptor binding Air, Surface Environmental, and Personal Protective Equipment Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) From a Symptomatic Patient Aerosol and Surface Stability of SARS-CoV-2 as compared with SARS-CoV-1 Interpreting a covid-19 test result Surface sampling of coronavirus disease (COVID-19): a practical "how to" protocol for health care and public health professionals Infection prevention and control during health care when novel coronavirus (nCoV) infection is suspected. Interim Guidance Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations Environmental contamination of the SARS-CoV-2 in healthcare premises: An urgent call for protection for healthcare workers Detection and evaluation of SARS-CoV-2 nucleic acid contamination in corona virus disease 19 ward surroundings and the surface of medical staff 's protective equipment. Beijing Da Xue Xue Bao Yi Xue Ban