key: cord-0829805-w8ni1hr5 authors: Lendvay, Thomas Sean; Chen, James; Harcourt, Brian H.; Scholte, Florine E. M.; Lin, Ying Ling; Kilinc-Balci, F. Selcen; Lamb, Molly M.; Homdayjanakul, Kamonthip; Cui, Yi; Price, Amy; Heyne, Belinda; Sahni, Jaya; Kabra, Kareem B.; Lin, Yi-Chan; Evans, David; Mores, Christopher N.; Page, Ken; Chu, Larry F.; Haubruge, Eric; Thiry, Etienne; Ludwig-Begall, Louisa F.; Wielick, Constance; Clark, Tanner; Wagner, Thor; Timm, Emily; Gallagher, Thomas; Faris, Peter; Macia, Nicolas; Mackie, Cyrus J.; Simmons, Sarah M.; Reader, Susan; Malott, Rebecca; Hope, Karen; Davies, Jan M.; Tritsch, Sarah R.; Dams, Lorène; Nauwynck, Hans; Willaert, Jean-Francois; De Jaeger, Simon; Liao, Lei; Zhao, Mervin; Laperre, Jan; Jolois, Olivier; Smit, Sarah J.; Patel, Alpa N.; Mayo, Mark; Parker, Rod; Molloy-Simard, Vanessa; Lemyre, Jean-Luc; Chu, Steven; Conly, John M.; Chu, May C. title: Addressing personal protective equipment (PPE) decontamination: Methylene blue and light inactivates severe acute respiratory coronavirus virus 2 (SARS-CoV-2) on N95 respirators and medical masks with maintenance of integrity and fit date: 2021-05-21 journal: Infection control and hospital epidemiology DOI: 10.1017/ice.2021.230 sha: 88204f5cf23d0d770d78b7e8c5f3fa047359c3f8 doc_id: 829805 cord_uid: w8ni1hr5 OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic has resulted in shortages of personal protective equipment (PPE), underscoring the urgent need for simple, efficient, and inexpensive methods to decontaminate masks and respirators exposed to severe acute respiratory coronavirus virus 2 (SARS-CoV-2). We hypothesized that methylene blue (MB) photochemical treatment, which has various clinical applications, could decontaminate PPE contaminated with coronavirus. DESIGN: The 2 arms of the study included (1) PPE inoculation with coronaviruses followed by MB with light (MBL) decontamination treatment and (2) PPE treatment with MBL for 5 cycles of decontamination to determine maintenance of PPE performance. METHODS: MBL treatment was used to inactivate coronaviruses on 3 N95 filtering facepiece respirator (FFR) and 2 medical mask models. We inoculated FFR and medical mask materials with 3 coronaviruses, including SARS-CoV-2, and we treated them with 10 µM MB and exposed them to 50,000 lux of white light or 12,500 lux of red light for 30 minutes. In parallel, integrity was assessed after 5 cycles of decontamination using multiple US and international test methods, and the process was compared with the FDA-authorized vaporized hydrogen peroxide plus ozone (VHP+O(3)) decontamination method. RESULTS: Overall, MBL robustly and consistently inactivated all 3 coronaviruses with 99.8% to >99.9% virus inactivation across all FFRs and medical masks tested. FFR and medical mask integrity was maintained after 5 cycles of MBL treatment, whereas 1 FFR model failed after 5 cycles of VHP+O(3). CONCLUSIONS: MBL treatment decontaminated respirators and masks by inactivating 3 tested coronaviruses without compromising integrity through 5 cycles of decontamination. MBL decontamination is effective, is low cost, and does not require specialized equipment, making it applicable in low- to high-resource settings. hypothesized that methylene blue (MB) photochemical treatment, which has various clinical applications, could decontaminate PPE contaminated with coronavirus. Design: The 2 arms of the study included (1) PPE inoculation with coronaviruses followed by MB with light (MBL) decontamination treatment and (2) PPE treatment with MBL for 5 cycles of decontamination to determine maintenance of PPE performance. Methods: MBL treatment was used to inactivate coronaviruses on 3 N95 filtering facepiece respirator (FFR) and 2 medical mask models. We inoculated FFR and medical mask materials with 3 coronaviruses, including SARS-CoV-2, and we treated them with 10 μM MB and exposed them to 50,000 lux of white light or 12,500 lux of red light for 30 minutes. In parallel, integrity was assessed after 5 cycles of decontamination using multiple US and international test methods, and the process was compared with the FDA-authorized vaporized hydrogen peroxide plus ozone (VHPþO 3 ) decontamination method. Results: Overall, MBL robustly and consistently inactivated all 3 coronaviruses with 99.8% to >99.9% virus inactivation across all FFRs and medical masks tested. FFR and medical mask integrity was maintained after 5 cycles of MBL treatment, whereas 1 FFR model failed after 5 cycles of VHPþO 3 . Conclusions: MBL treatment decontaminated respirators and masks by inactivating 3 tested coronaviruses without compromising integrity through 5 cycles of decontamination. MBL decontamination is effective, is low cost, and does not require specialized equipment, making it applicable in low-to high-resource settings. The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory coronavirus virus 2 (SARS-CoV-2) has resulted in critical personal protective equipment (PPE) shortages, especially filtering facepiece respirators (FFRs, also known as N95 respirators). Although designed for single-use, healthcare personnel (HCP) are reusing potentially contaminated FFRs and medical masks (MMs) on an emergency basis due to supply shortages. These shortages have necessitated the rapid development and deployment of decontamination processes, leading to the World Health Organization (WHO) issuing interim guidance on rational PPE use. 1 The US Food and Drug Administration (FDA) granted emergency use authorization of hydrogen peroxide and steam sterilization systems to decontaminate FFRs for reuse. 2, 3 These technologies remain less available in low-resource settings, where frontline HCP have inadequate protection 4, 5 ; thus, novel methods for PPE decontamination are needed. Photochemical disinfection uses a photosensitive chemical that, combined with visible light, generates singlet oxygen (Supplementary Material online). Singlet oxygen inactivates viruses by damaging viral nucleic acids and membranes. 6 One such photosensitizer is methylene blue (MB), which is FDA-approved to treat methemoglobinemia and is used to sterilize human plasma transfusions in Europe. 7 MB inactivates SARS-CoV-2 and many other viruses (Supplementary Table S3 online). [8] [9] [10] In this Development and Methods for N95 Respirators and Mask Decontamination (DeMaND) study, we evaluated methods that inactivate SARS-CoV-2 on respirators and masks that can be applied anywhere at low cost. We sought to determine whether MB with light (MBL) could effectively decontaminate commonly used FFRs and medical masks while maintaining mask integrity (i.e., filtration, breathability, fluid resistance, and fit) after multiple decontamination cycles. We leveraged 4 virology laboratories and 6 PPE integrity testing sites to examine the MBL virucidal effect on 2 SARS-CoV-2 isolates (betacoronavirus) and 2 coronaviruses requiring a lower level of biocontainment (the betacoronavirus murine hepatitis virus (MHV) and the alphacoronavirus porcine respiratory coronavirus (PRCV)) and (2) to determine the impact of 5 cycles of decontamination on PPE integrity (Fig. 1) . We selected the number of decontamination cycles based on the Centers for Disease Control and Prevention (CDC)'s recommended maximum number of donnings as part of crisis capacity strategies at the time this study was conducted. 11 We chose FFRs and medical masks based on availability during recent outbreak responses and variations in shape, material, and structure. For integrity testing, we compared MBL to the FDA-authorized vaporized hydrogen peroxide plus ozone system (VHPþO 3 ). 2 We tested 3 FFR and 2 medical mask models, both fluid-resistant and non-fluid-resistant ( Supplementary Fig. S9 online) . These FFRs are surgical FFRs which are National Institute of Occupational Safety and Health (NIOSH)-approved particulate respirators cleared by FDA as medical devices (Supplementary Table S1 testing matrix online). We obtained SARS-CoV-2 isolates from a patient at the George Washington University Hospital (Lab 1) and from Dr. Darryl Falzarano at the Vaccine and Infectious Disease Organization (Lab 2; GISAID accession no. EPI_ISL_425177). We used a SARS-CoV-2 clinical sputum specimen with University of Calgary Conjoint Health Research Ethics Board approval (no. REB20-0444). Recombinant MHV strain rA59-E-FL-M and PRCV strain 91V44 have been described previously. [12] [13] [14] [15] We cut FFRs and medical masks into 7×10-mm coupons and inoculated them with the maximum available virus dose of SARS-CoV-2 or MHV on the outer layer (or inner layer where specified) with a pipette and dried them for 20 minutes before treatment. Virus was eluted in media using a vortexer or orbital rocker. Alternatively, we injected PRCV under the outer layer, then we excised 34×34-mm coupons and eluted using a vortexer. We quantified the remaining infectious virus by median tissue culture infectious dose (TCID 50 ) or plaque assays. We added 10 μM MB to the inoculated coupons or sprayed it on intact inoculated masks. We exposed them to 50,000 lux of white light or 12,500 lux of red light for 30 minutes. We used red light at a lower intensity because red light contains a higher percentage of wavelengths that activate MB ( Supplementary Fig. S1 online). Dark controls were left in the biosafety cabinet with the light off or were covered with aluminum foil (<100 lux). We soaked 3M Panel respirator (model 1870þ, hereafter R3) coupons with 10 μM MB for >1 hour and dried them for 2 days protected from light for pretreatment testing. We then spotted SARS-CoV-2 on outer or inner mask layers and dried these coupons for 20 minutes before exposing them to 50,000 lux of white light for 30 minutes. Intact 3M half-sphere respirator (model 1860, hereafter RM) and Type II RASTM F2100 Level 2 Halyard face mask (hereafter FH) were sprayed with 7-8 mL 10 μM MB and dried overnight. We added MHV to 3 points on the outer surface, dried for 20 minutes and exposed them to light (50,000 lux) for 30 minutes. We then excised the inoculated area, eluted, and quantified the virus by TCID 50 assay. The Seattle Children's Research Institute, George Washington University, University of Calgary, and Nelson Laboratories used lightboxes developed at Colorado State University that included 4000K Husky LED lights. The University of Alberta used 3500K Husky LEDs in their lightboxes. The University of Liège and Centexbel used a custom lightbox containing horticultural lamps. All laboratories verified light intensity using light meters (Supplementary Methods online). We assessed FFR and medical mask integrity by determining filtration efficiency, breathability, fluid resistance, and fit. We tested FFRs and medical masks untreated and after 5 cycles of decontamination with VHPþO 3 or 10 μM MB plus white light (50,000 lux) or red light (12,500 lux) for 60 minutes. For the VHPþO 3 treatment, we used the preset cycle (cycle 1) of the Sterizone VP4 Sterilizer (Stryker, Québec, Québec, Canada) at 41°C. We assessed filtration efficiency using NaCl submicron chargedneutralized particles ranging in size from 0.022 to 0.259 μm with Table S1 (online) for the respirator and mask decontamination and testing matrix. a median count diameter of 0.075 ± 0.020 μm and a geometric standard deviation of <1.86 to give a mass median aerodynamic diameter of 0.3 μm, with airflow at 85 L/minute (simulating inhalation at heavy workload). 16 We measured bacterial filtration efficiency of medical masks using aerosolized droplets containing Staphylococcus aureus at a 28.3 L/minute air flow rate (Supplementary Methods and Results online). 17 We assessed breathability by measuring inhalation and exhalation breathing resistances using standard test methods, 18, 19 and we used pressure-drop measurements for medical masks. 17 Additionally, we determined Sheffield Dummy airflow differences for both FFRs and medical masks (Supplemental Methods and Results online). Testing of resistance to splash and spray by synthetic blood is required for surgical masks in the United States and fluid-resistant medical masks in Europe. We tested fluid resistance for medical masks (Supplemental Methods and Results online). We conducted human fit testing with the PortaCount Proþ 8038 (TSI, Shoreview, MN). Fit testing was exempted from ethics board review by both the Research Compliance Office of Stanford University and the Conjoint Health Research Ethics Board of the University of Calgary. We tested multiple dynamic tasks: regular breathing, heavy breathing, turning head side-to-side, moving head up-and-down, talking, and bending over while breathing. We performed each set of tests twice and calculated a fit factor for each mask. According to the NIOSH/National Personal Protective Technology Laboratory (NPPTL) Decontaminated Respirator Assessment Plan, we conducted manikin fit testing using an advanced, realistic manikin head. 16 We examined the changes in the elastic recovery of the FFR straps and medical-mask ear loops to determine strap and ear-loop integrity changes after 5 cycles of decontamination (Supplementary Methods and Results online). We calculated means and standard deviations or percentage passing of each integrity test method separately by FFR or medical mask model. We combined data for integrity test methods conducted at >1 test site to create overall means and standard deviations or percentage passing. We tested the normality of the data distribution using the Shapiro-Wilk test. We calculated significant differences between untreated and treated FFRs and medical masks using the Student t-test, the Mann-Whitney U test, or the Fisher exact test, as appropriate. We used SAS version 9.4 software (SAS Institute, Cary, NC) for the analysis. We confirmed that MBL can inactivate a coronavirus with varying concentrations of MB when mixed with PRCV and exposed to red light (12,500 lux). Treatment with 0.1 μM MB plus light resulted in complete inactivation. In the absence of additional light, complete inactivation required a dose of 1 μM MB ( Fig. 2A) . We observed that MBL specifically reduced SARS-CoV-2 infectivity with varying concentrations of MB when mixed with SARS-CoV-2 and exposed to 50,000 lux of white light. MB inhibited SARS-CoV-2 infectivity with a dose-dependent effect, with or without exposure to light. This virucidal effect was enhanced in the presence of light (Fig. 2B) . When we cut coupons from a representative FFR (R3) or medical mask (Type II EN14 683 generic face mask, hereafter FW) and inoculated and treated them with MBL for the indicated periods, we observed that both viruses were sensitive to MBL treatment. Using 10 μM MB and light resulted in complete inactivation of SARS-CoV-2 and MHV on both FFR and medical mask materials after 5 minutes (Fig. 3) . Using 1 μM MB, we observed complete inactivation after 30 minutes of light exposure, though we observed a 2-4 log viral titer reduction after 5 minutes. MB Plates were either exposed to red light (12,500 lux) for 30 minutes or were protected from light (<100 lux). The dotted line indicates the limit of detection. (B) We added serial dilutions of MB to wells of a 12-well plate containing~50 PFU SARS-CoV-2 in MEM plus 15% FCS. Plates were either exposed to white light (50,000 lux) for 45 minutes or protected from light (<100 lux). We determined viral titers using 2-3 replicate samples. Note. FCS, fetal calf serum; MEM, minimum essential media, ND, not detected. treatment in the absence of additional light also resulted in a substantial reduction of viral titers. To ensure that MBL can efficiently decontaminate a variety of masks, we tested 3 more masks, including 2 additional FFRs, hereafter RH, and RM), and 1 additional medical mask (FH). We inoculated coupons or intact masks, treated with 10 μM MB and exposed to light for 30 minutes (Fig. 4A-D) , conditions that demonstrated robust inactivation in the previous experiment. We observed complete inactivation (up to 4 log reduction) of SARS-CoV-2 for all respirators and masks tested. Treatment with MB without exposure to white light resulted in substantial virus reduction (Fig. 4C) . We observed complete inactivation (4-5 log reduction) of MHV for FH, R3, RH, and RM masks. A low level of the virus was detectable in 1 replicate for FW (Fig. 4A ). For PRCV, which was injected under the outer mask layer, we observed a >5-log virus reduction after treatment of FH, FW, R3, and RH masks. In contrast, we observed a 3-log reduction in RM (Fig. 4D) . The overall percent reduction in virus titer after treatment across all FFRs/MMs and viruses ranged from 99.8% to >99.9% (Table 1) . In addition, we tested the effect of MBL inactivation on FFR and medical mask straps inoculated with PRCV and noted a 2-4 log reduction in titers ( Supplementary Fig. S4 online) . We examined 3 potential applications of MBL in a clinical environment. First, because some clinical settings may not have access to We applied a 10-μL aliquot of MHV or SARS-CoV-2 to coupons derived from an FFR (R3) or medical mask (FW) and they were left to dry for 20 minutes. Subsequently, we added 10 or 30 μL MB to each coupon at the indicated concentrations. We exposed the samples to white light (50,000 lux) for the indicated periods or left them in the biosafety cabinet with the lights off. We measured each virus titer using 2-6 replicate samples by TCID 50 or plaque assay. Data are represented as mean ± SD. Note. PFU, plaque forming units; R3, 3M panel respirator (1870þ) FW, Type II EN 14683 generic face mask. The dotted line indicates the limit of detection. bright light, we investigated whether 10 μM MB and ambient light would be sufficient to inactivate SARS-CoV-2. MB treatment and exposure to 700 lux (ambient light generated by light in a biosafety cabinet) for 60 minutes inactivated SARS-CoV-2 at nearly 5 log reduction. MB and <100 lux of light inactivated virus at almost 3 log reduction (Fig. 5A) . Second, we investigated the possibility of pretreating respirators or masks with MB. After treating coupons with 10 μM MB, drying overnight, and inoculating them with SARS-CoV-2 on either the hydrophobic outer layer or the hydrophilic inner layer before exposure to 50,000 lux of white light for 30 minutes, we could not recover We applied a 10-μL aliquot of SARS-CoV-2 to R3 coupons and dried them for 20 minutes. We added 10 μL of 10 μM MB to each coupon before treatment with 700 lux (the light level produced by the biosafety hood lights) or <100 lux of light. (B) Effect of MB pretreatment on SARS-CoV-2 inactivation. We cut coupons from R3 masks and soaked them for 1 hour in 10 μM MB. We then dried the coupons in the dark for 2 days before adding 10 μL virus to either the inner or outer layers. We exposed the samples to white light (50,000 lux) for 30 minutes and determined the virus titer by plaque assay. (C) Inactivation of a SARS-CoV-2 clinical specimen by MBL. We obtained a saliva specimen from a COVID-19 patient with a titer of 1.1 × 10 5 PFU/mL for SARS-CoV-2. We applied 10 μL aliquots to coupons cut from an R3 mask, treated with 10 μM MB and exposed to white light (50,000 lux) for 30 minutes. We determined virus titer by plaque assay. (D) Effect of MB pretreatment on MHV inactivation using intact masks. We pretreated intact RM and FH masks with 10 μM MB by spraying the front and back with a total of 7-8 mL MB and allowed them to dry overnight in the dark. We inoculated the dried masks with MHV and exposed them to white light (50,000 lux) for 30 minutes. We then excised inoculated areas before elution and titration. We determined the virus titer by TCID 50 assay. Note. ND, not detected; R3, 3M panel respirator (1870þ); RM, 3M 1860 half-sphere respirator; FH, Type IIR Halyard face mask. The dotted line indicates the limit of detection. infectious virus from either side of the light-exposed coupons, signifying inactivation of >4 logs of virus (Fig. 5B) . We sprayed intact RM respirators and FH masks with 10 μM MB, dried them overnight, inoculated them with MHV, and exposed them to 50,000 lux of white light for 30 minutes. No viable virus was recovered (Fig. 5D) . Lastly, upon adding 10 μL of a clinical specimen (saliva) with a titer of 1.15 × 10 5 PFU/mL obtained from a COVID-19 patient onto respirator coupons and treating them with 10 μM MB and white light (50,000 lux) for 30 minutes, we observed no viable virus after treatment. This result indicates the potential for this inactivation method in clinical settings in which viable virus may be protected by proteinaceous matrixes (Fig. 5C ). We employed standard test methods to determine whether MBL decontamination affected integrity, and we compared the results to those of the FDA-authorized VHPþO 3 decontamination method. The following sections describe each of the integrity test methods and results (Supplementary Tables S2A-B online for complete results) . Additional testing for medical masks included bacterial filtration efficiency, differential pressure, Sheffield dummy airflow differences, fluid (splash) resistance, and earloop integrity testing. Sheffield dummy airflow resistance and strap integrity testing were also conducted on FFRs (Supplemental Figs. S5-S8 online). Figure 6A depicts the filtration efficiency before (untreated) and after 5 cycles of decontamination with MBL and VHPþO 3 . We expected high filtration efficiencies for the FFRs because they are all NIOSH-approved N95 FFRs, which require ≥95% submicron filtration efficiency. All FFR models surpassed the minimum 95% filtration efficiency requirement before and after 5 cycles of decontamination using each method. Untreated FW and FH masks achieved 76% and 86% submicron filtration efficiency, respectively. Overall, MBL and VHPþO 3 treatment of FFRs and medical masks did not cause any significant differences in the submicron filtration efficiency of the studied models (P > .01). Medical mask models continued to meet requirements of bacterial filtration efficiency after 5 cycles of decontamination ( Supplementary Fig. S5 and Table S2A online). The resistance to airflow via inhalation and exhalation (breathability), is an indication of the difficulty in breathing through the respirators or masks. The FFR models achieved inhalation and exhalation resistances >60% below respective NIOSH 42 CFR Part 84 and EN 149 allowable maximum airflow resistance requirements after 5 cycles of decontamination (Fig. 6B, C) . These resistance changes would not make it harder to breathe through the mask. Medical masks demonstrated similar inhalation resistances, and lower exhalation resistance values compared to FFRs after 5 cycles of decontamination. Both medical mask models were below their respective allowable maximum differential pressure limit after 5 cycles of decontamination ( Supplementary Fig. S6 and Table S2A ). Furthermore, we determined airflow differences of FFRs and medical masks using Sheffield Dummy simulated breathing ( Supplementary Fig. S7 and Table S2A -B online). The MBL treatment did not affect the breathability of FFRs or medical masks, in terms of either inhalation and exhalation resistance or pressure drop. We evaluated medical masks for their fluid (splash) resistance by challenging inside and outside of the masks with a small volume (∼2 mL) of a high-velocity stream of synthetic blood. In general, we observed that the decontamination process did not negatively impact the fluid resistance properties of the medical masks (Supplementary Fig. S8 and Table S2A online). Fit testing measures how well a respirator or mask seals around the contours of the face. A good fit ensures that exchanged air is filtered through the respirator. Human fit testing demonstrated that respirators maintained quantitative fit values, or fit factors, above 100 after 5 cycles of decontamination. In contrast, VHPþO 3 decontamination decreased RH fit and RM fit to the point of failure (Fig. 7A) . Notably, 2 VHPþO 3 decontamination cycles are the maximum authorized by FDA for N95 FFRs for the used system. 20 We also performed human fit testing for the medical masks to demonstrate that these types of masks are not designed to ensure a tight fit (Fig. 7A ). On some of the VHPþO 3 -treated FFRs and medical masks, human participants noted a "strong acrid odor" and some observed partial elasticity loss on treated straps and ear loops, and discoloration of the nosepiece foams (RM only). In contrast, some participants wearing the MBL-treated FFRs noted a "not unpleasant slight odor" at one of the fit testing sites. In addition to the discoloration, the nose bridge was more rigid for the 3 MBL-treated RMs. We determined the manikin fit factor using an advanced, realistic manikin head form, which resulted in similar overall passing of OSHA criterion of 100 fit factor for all 3 FFRs (Fig. 7B) . 16, 21 Observed differences between human and manikin fit can be attributed to testing procedure variability and structural facial variations. FFRs do not provide a universal fit for all wearers. Overall, MBL decontamination after 5 cycles of decontamination did not negatively impact integrity performance and fit while the VHPþO 3 decontamination yielded some detrimental performance issues. We have demonstrated that MB activated by white or red light effectively inactivates SARS-CoV-2 on FFR and medical mask surfaces and with a clinical specimen without affecting the integrity. MBL can be applied as a decontamination method for single-use FFRs and medical masks. Residual MB on the mask surface could potentially provide a novel means of continual inactivation of viral particles to decontaminate a mask while donned because MB inactivated SARS-CoV-2 on mask surfaces even under ambient light conditions. For decades, MB has been recognized to have decontamination capabilities against a range of viral and bacterial pathogens, [7] [8] [9] 22 and MB is currently used to decontaminate plasma for transfusion 23 and to sterilize convalescent serum for COVID-19 treatment. 10 MBL is suitable for high-and low-resource settings because MB is inexpensive, globally available, and it does not require specialized equipment. Light sources can vary from white high-intensity lamps to ambient lighting to generate singlet oxygen (Supplementary Table S6 online). Future studies are warranted to investigate whether MBL could be used to inactivate additional pathogens and to decontaminate other forms of PPE such as gowns, gloves, and boots. We performed human fit testing with volunteer participants who adjusted the FFRs and medical masks to achieve the highest fit factor or seal and subsequently performed head movements and remeasured fit or seal. (B) Manikin fit factors using advanced, realistic manikin headforms is a reproducible method to test fit without volunteer participants. We used the PortaCount PROþ 8038 machine (TSI, Inc, Shoreview, MN) to determine the overall fit for both human participants and manikins headforms. *Indicates significantly different values between treated and untreated FFR or medical mask at P < .05, Student t-test or Mann-Whitney U test, as appropriate. **Horizontal line represents the following standard: Per OSHA 1910.134(f), if the overall fit factor as determined through an OSHAaccepted quantitative fit-testing protocol is ≥100 for tight-fitting half facepieces, then the fittest has been passed for that respirator. Percentages on or above each bar represent % of respirators or masks tested that surpassed this standard. Although the standard does not apply to face masks, we present the % to note the strong difference between respirator and face mask test results. Note. RH, Halyard duckbill respirator (Fluidshield-46727); RM, 3M half-sphere respirator (1860); R3, 3M panel respirator (1870þ); FW, EN 14683 Type II generic face mask; FH, ASTM F2100 Level 2 Halyard face mask. Our study has several limitations. We only tested a minority of FFR and medical mask models, yet there are ∼500 NIOSHapproved FFR models, and many others are used globally. MBL worked well on all FFRs and medical masks tested, except the "RM" FFR possibly owing to a distinct design characteristic that resulted in the variable outcome. In 2020, the CDC recommended that a decontamination method's effectiveness be evaluated for specific FFR models in collaboration with the manufacturer, and if needed, a third-party laboratory. 24 Although the N95 respirator reuse recommendation has been lifted in the United States, in other nations where PPE is reused, reusers may want to follow this guideline. During our integrity testing, we did not simulate extended wear or multiple donnings and doffings, which could affect FFR fit and performance. 25, 26 In addition, off-gassing of MB or VHPþO 3 was not evaluated. The biocompatibility of MB wearer inhalation was not tested, however, MB concentrations used were below those administered clinically (intravenously, orally, or intranasally). 7, 27, 28 If the entire dose of 10 μM MB sprayed onto a mask was inhaled, which is unlikely, the total inhaled dosage would be 0.02 mg. The quantity of MB inhalation over time while wearing an MB-pretreated mask is under investigation. We generalized our findings by demonstrating complete MBL inactivation employing the same methodology across multiple virology laboratories using 3 coronavirus species and a SARS-CoV-2 clinical sample. This signifies that emergent variants of SARS-CoV-2 would also be inactivated by MBL and that viruses requiring lower levels of biocontainment can be used for similar inactivation studies. Integrity tests in multiple testing centers using heterogeneous light administration methods reaffirms the reproducibility of our findings, and we replicated practical light scenarios expected in real-world settings. In conclusion, MBL treatment inactivates SARS-CoV-2 on FFRs and medical masks without decreasing integrity and fit. Our findings provide a method for inexpensive, accessible, effective decontamination of PPE for reuse, applicable in high-and low-resource settings during supply shortages. Pretreatment of masks with MB could provide a novel means of continual decontamination reducing exposure to SARS-CoV-2. Rational use of personal protective equipment for coronavirus disease (COVID-19) and considerations during severe shortages. World Health Organization website Decontamination systems for personal protective equipment EUAs, 2020; 1-4. US Food and Drug Administration website Final Report for the Bioquell hydrogen peroxide vapor (HPV) decontamination for reuse of N95 respirators, Battelle. US Food and Drug Administration website Global shortage of personal protective equipment Looming threat of COVID-19 infection in Africa: act collectively, and fast Photodynamic inactivation of mammalian viruses and bacteriophages Updates on pathogen inactivation of plasma using Theraflex methylene blue system Inactivation of Ebola virus and Middle East respiratory syndrome coronavirus in platelet concentrates and plasma by ultraviolet C light and methylene blue plus visible light Inactivation of three emerging viruses-severe acute respiratory syndrome coronavirus, Crimean-Congo haemorrhagic fever virus and Nipah virus-in platelet concentrates by ultraviolet C light and in plasma by methylene blue plus visible light Effectiveness of convalescent plasma therapy in severe COVID-19 patients Impact of multiple consecutive donnings on filtering facepiece respirator fit Envelope protein palmitoylations are crucial for murine coronavirus assembly Isolation of a porcine respiratory, nonenteric coronavirus related to transmissible gastroenteritis Evidence for a porcine respiratory coronavirus, antigenically similar to transmissible gastroenteritis virus, in the United States Sites of replication of a porcine respiratory coronavirus related to transmissible gastroenteritis virus Assessment of filter penetration performance and fit for decontaminated N95 respirators. NPPTL Assessment to Support the COVID-19 Response National Personal Protective Technology Laboratory National Institute for Occupational Safety and Health Centers for Disease Control and Prevention Standard Specification for Performance of Materials used in Medical Face Mask Determination of exhalation resistance test, air-purifying respirators standard testing procedure (STP) US Food and Drug Administration website Development of an advanced respirator fit-test headform The photodynamic action of methylene blue on bacteriophage World health organization model list of essential medicines. Mental and Holistic Health: Some International Perspectives Implementing filtering facepiece respirator (FFR) reuse, including reuse after decontamination, when there are known shortages of N95 respirators Correlation between N95 extended use and reuse and fit failure in an emergency department Impact of extended use and decontamination with vaporized hydrogen peroxide on N95 respirator fit Pharmacokinetic interaction of chloroquine and methylene blue combination against malaria Laser-assisted nasal decolonization of Staphylococcus aureus, including methicillin-resistant Staphylococcus aureus Acknowledgments. We all thank the human fit-testing participants and the patients from whom the original SARS-CoV-2 specimens were obtained for the virology testing. M.C.C. thanks the contribution of the NIOSH National Personal Protective Technology Laboratory: Jonisha P. Pollard, Michael S.