key: cord-0829605-ie8yxc0f authors: Wang, Yung-Chih; Lin, Sheng-Wen; Wang, I-Jen; Yang, Chung-Yao; Hong, Chitsung; Sun, Jun-Ren; Feng, Po-Hao; Lee, Mei-Hui; Shen, Ching-Fen; Lee, Yi-Tzu; Cheng, Chao-Min title: Interleukin-6 Test Strip Combined With a Spectrum-Based Optical Reader for Early Recognition of COVID-19 Patients With Risk of Respiratory Failure date: 2022-02-15 journal: Front Bioeng Biotechnol DOI: 10.3389/fbioe.2022.796996 sha: 3df9beed9c2f1de8258311898b5172256c02813b doc_id: 829605 cord_uid: ie8yxc0f The COVID-19 pandemic has had a globally devastating impact. This highly contagious virus has significantly overburdened and undermined medical systems. While most infected patients experience only mild symptoms, those who are severely affect require urgent medical interventions and some develop acute respiratory failure and require mechanical ventilation. The broad and potentially deadly impact of infection underscores the critical need for early recognition, especially for those at risk for respiratory failure. Those who are severely impacted and at high risk for respiratory failure have been found to present high levels of serum cytokines, such as interleukin-6 (IL-6). Timely diagnosis and management of those at risk for respiratory failure is crucial. Measurement of IL-6 may provide a means for distinguishing such patients. Currently, most serum IL-6 detection relies on the use of laboratory-based conventional enzyme-linked immunosorbent assays. Although some rapid assays have been developed recently, they need to be conducted by specific technicians in central laboratory settings with advanced and expensive equipment. In this study, we propose an IL-6 test strip combined with a spectrum-based optical reader for early recognition of COVID-19-infected patients at imminent risk of acute respiratory failure requiring mechanical ventilator support. For our analyses, clinical demographic data and sera samples were obtained from three medical centers, and test strip specificity and detection performance were analyzed. This would help healthcare personnel stratify the risk of respiratory failure and provide prompt, and suitable management. Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) causing Coronavirus disease 2019 has spread to pandemic levels, as designated on 11 March 2020 by the World Health Organization (WHO), and has accounted for more than 233, 136, 147 confirmed cases and 4,771,408 deaths as of 30 September 2021 (WHO, 2021) . While most patients presented without symptoms or with mild to moderate symptoms, including fever, cough, fatigue, myalgias, nausea, and diarrhea, some may develop respiratory failure Wu et al., 2020; Zhou et al., 2020) . The rapid progression toward acute respiratory failure was the primary cause of mortality with an estimated case-fatality rate of approximately 2.1% to date (Grasselli et al., 2020; Huang et al., 2020) . Cytokine release syndrome (CRS) has been thought to contribute to pathogenesis in severe COVID-19 cases (Fajgenbaum and June 2020; Moore and June 2020) . Several biomarkers, such as procalcitonin Khodeir et al., 2021) , C-reactive protein Khodeir et al., 2021) , interleukin-6 (IL-6) (Jørgensen et al., 2020; Liu et al., 2020; Khodeir et al., 2021) , and monocyte chemotactic protein-1 (MCP-1) Jørgensen et al., 2020) have been found to be associated with prognosis or disease severity in patients with COVID-19. As an important mediator of CRS, IL-6 appears to be correlated to respiratory failure (Jørgensen et al., 2020; Leisman et al., 2020; Moore and June 2020) , acute respiratory distress syndrome (Leisman et al., 2020; Moore and June 2020) , and adverse clinical outcomes (Del Valle et al., 2020; Moore and June 2020) . While patients experiencing CRS had worsening clinical outcomes (Fajgenbaum and June 2020; Mangalmurti and Hunter, 2020) , the early recognition of this immunological status could assist timely identification of patients who will progress to acute respiratory failure. It is important to distinguish between those with urgent medical needs from those experiencing only mild symptoms to avoid overloading medical care systems. The breadth and scope of infection during a pandemic urges the need for an easy-to-use, inexpensive diagnostic tool to facilitate early diagnosis for those who are at high risk of respiratory failure. Enzyme-linked immunosorbent assay (ELISA) is a frequently used, well-developed (Lequin, 2005) , traditional tool for measuring IL-6 concentration in laboratories (Yin et al., 2017) . However, ELISA protocol requires multiple procedures and is time-consuming (Lequin, 2005) . A point-of-care (POC) diagnostic tool for detection of IL-6 could overcome the drawbacks of traditional ELISA, such as time consuming, and need to be performed with multiple steps. The POC diagnostic tool could provide the results within minutes with only 1 to 2 steps and helps clinicians perform early-stage diagnosis of patients at risk for respiratory failure. Here, we proposed the use of a rapid IL-6 test strip which contains a lateral flow immunoassay (LFA)-based kit accompanied by a handheld optical reader that, in combination, is well suited for recognizing acute respiratory failure among COVID-19 patients. The spectrum-based optical reader is a palm-size portable chipbased spectrometric device (Hung et al., 2021) , based on innovative micro-grating technology applied for biomedical spectral analysis (Kita et al., 2018; Wang et al., 2020a) . In this study, we aimed to use a combination of an LFA technique-based IL-6 test strip and a sensitivity-enhanced spectrometric reader for early recognition of COVID-19 patients who may develop respiratory failure. We believe that this device could be a useful diagnostic tool for early identification of COVID-19infected patients at risk for respiratory failure. Blood samples were obtained from patients diagnosed as COVID-19 from April 2020 to June 2021 at three hospitals in Taiwan: Tri-Service General Hospital (TSGH), Shuang Ho Hospital (SHH), and Taipei Hospital (TH) of Ministry of Health and Welfare (MOHW) in Northern Taiwan. The study protocol was approved by the institutional review boards (IRBs) of each site (TSGH: IRB No. C202005067, SHH: TMU-JIRB No. N202004076, TH: TH-IRB-0020-0011). The positive COVID-19 diagnosis was confirmed by real-time polymerase chain reaction testing for SARS-CoV-2 from nasopharyngeal samples. We reviewed patient medical records to retrieve clinical information, including the diagnosis of pneumonia and acute respiratory failure with mechanical ventilation. The severity of the COVID-19 was calssified according to the Infectious Diseases Society of America (IDSA) guidelines (Bhimraj et al., 2020) . Critical illness was defined as patients on mechanical ventilation or extracorporeal membrane oxygenation (ECMO). Severe illness is defined as patients with SpO2 ≤94% on room air, including those on supplementary oxygen. Blood samples were obtained within 48 h after the diagnosis of COVID-19. Follow-up blood samples were obtained 2 weeks after admission. The blood collected from the patients were allowed to clot by leaving it undisturbed at room temperature for 15-30 min. The blood clots were removed by centrifuging at 1,000-2,000 g for 10 min and resulting supernatant is designated serum. The serum was stored at temperatures of -20°C for further experiments. Serum IL-6 concentrations were determined using commercially available ELISA kit (D6050, R&D systems, United States). The ELISA protocol was performed according to the manufacturer's recommendations. The test strip (created in cooperation with Taiwan Hygeia Touch Inc.) was developed based on the use of colloidal gold-conjugated anti-IL-6-antibody (ARG21446, arigo Biolaboratories Corp., Hsinchu, Taiwan) to detect human IL-6 ( Figure 1A ). An Frontiers in Bioengineering and Biotechnology | www.frontiersin.org February 2022 | Volume 10 | Article 796996 optimization test was performed to determine the most appropriate combination of IL-6 quantity and gold nanoparticle size for conjugation, which was based on colorimetric analysis of each combination. After the optimization test was performed, we used both a 15 nmdiameter gold colloid and an anti-IL-6 antibody (1 mg/ml) to prepare the IL-6 strip as previously described (Lin et al., 2021) . The test strip was pre-coated with capture reagents by spraying it to create perpendicular lines of human anti-IL-6 antibodies (ARG21444, arigo Biolaboratories Corp., Hsinchu, Taiwan) conjugated with 15 nm-diameter gold colloids. This nitrocellulose strip was also coated with anti-mouse IgG monoclonal antibody (ARG21957, arigo Biolaboratories Corp., Hsinchu, Taiwan) at the test line (T line), as well as the same amount of the quality control antibody at the control line (C line). As the applied sample flowed down the strip, the human IL-6 antigen present in the sample formed an antigen complexed with the colloidal gold-labeled anti-IL-6-antibody. These complexes are then captured in the perpendicular T line of the test strip, where they were displayed as colored bands. To examine the IL-6 of the tested samples, a total of 100 μl of stored sera was pipetted into the sample application port and onto the test membrane, which was pretreated with a gold particle-conjugated monoclonal antibody specific for IL-6. The IL-6 in the sample bound to the gold particle-conjugated monoclonal anti-IL-6 antibodies in the membrane as the sample diffused through it and produce a visible colored line. Color intensity was directly proportional to the concentration of IL-6 in the sample. This color intensified during incubation. Surplus gold particles continued to diffuse over the test unit. Conjugate-specific antibodies printed as another line on the membrane (control line, C) captured the rest of the gold conjugate and a distinctly visible line developed during incubation. After incubation for 5 min, the color intensities were detected using the spectrum-based optical reader. The qualitative result was generated using a stored lot specific standard curve. Pre-determined concentrations (0, 0.1, 0.2, and 0.4 ng/ml) of IL-6 were tested using the IL-6 LFA test strips. Color intensity results on each test strip were analyzed using the spectrum-based optical reader, and the concentration of the IL-6 was determined based on a cutoff value for the spectral intensity. Potential test result interference for our test strips was evaluated by examining the impact of various endogenous substances (bilirubin, hemoglobin, intralipid, rheumatoid factor, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-8, and IL-9). These substances were examined for their impact on test interference, and tests were performed in triplicate. The spectrum analyzer (in cooperation with Taiwan SpectroChip Inc.; Taiwan FDA: MD(I)-008090 and US FDA: 3017810861) was equipped with a cassette designed for rapid optical IL-6 antibody reflectance spectrum detection ( Figure 1B ). This spectrum-based optical reader provided continuous-spectrum, high-resolution reflectance values when reading the result of test line (IL-6 line) via an optical module. The primary reflectance wavelengths detected by using this spectrum reader were 540 and 470 nm with the main reference wavelength being 650 nm (Hung et al., 2021) . The α value was calculated using the ratio of the spectra at the minimum reflectance and reference wavelengths: α = Reflectance (650 nm)/Reflectance (the minimum value in the range of 430-600 nm). A higher α value indicates a stronger reflection color intensity of the colloidal gold antibody-conjugated IL-6 complex, which indicates a higher antibody concentration (Lin et al., 2021) . The Spearman's rank correlation coefficient and the Bland-Altman chart were used to check the correlation between our test strip/optical reader combination and ELISA. The sensitivity and specificity of the IL-6 test strips were also calculated. This study examined 50 blood samples obtained from 33 hospitalized patients with COVID-19. Among them, 10 (30.3%) patients had mild illness, 14 (42.42%) patients had COVID-19 pneumonia, and 9 patients (27.27%) had acute respiratory failure requiring intubation for respiratory support subsequent to Emergency Department presentation ( Table 1) . Because some of the study patients recovered well and experienced successful ventilator weaning, not all of them required a second blood sampling 2 weeks following diagnosis. To evaluate the cross-reactivity of the test strip, a total of four endogenous compounds were examined for their impact on test interference up to the concentrations listed in Supplementary Table S1 . No impact on results was observed from these tests, which were performed in triplicate. In addition, IL-6 (concentrations of approximately 0.1 ng/ml to 5 ng/ml) was mixed with seven other substances (Supplementary Table S2 ) to examine possible cross-reactivity. These substances demonstrated no influence on the IL-6 concentration results, indicating the high specificity of the IL-6 test strips. High-Performance Spectral Analysis for the IL-6 Test Strip Figure 2A shows that the correlation between the concentration of IL-6 test strip and ELISA were highly consistent, R 2 = 0.983. For patients requiring mechanical ventilation for acute respiratory failure ( Figure 2B) , the results of IL-6 test strip also exhibited a high correlation with ELISA results, R 2 = 0.974. In addition, in the spearman method, the correlation between the 50 blood samples tested and the correlation between the tested samples from those with mechanical ventilation are significantly different (p < 0.001), and the Rho is 0.576 and 0.962, respectively. The Bland-Altman plot shows the comparison of each difference between the two pairing methods with the measured average, as shown in Figure 2C . The performance of the device has been previously documented as providing a limit of detection and limit of quantification of 76.85 and 402.71 pg/ml, respectively (Lin et al., 2021) . Serum IL-6 concentration, presence of pneumonia, and the receipt of mechanical ventilation for acute respiratory failure are listed in Table 1 . Seven of the nine patients with mechanical ventilation had an elevated IL-6 concentration higher than 76.85 pg/ml (range: 76.85-7605 pg/ml). Using a cutoff value of 76.85 pg/ml, the IL-6 test strip exhibited 100% sensitivity and 96% specificity for the recognition of mechanical ventilation (Supplementary Table S3 ). Samples from two patients (sample No. 45 and No. 49 ) who received mechanical ventilation showed undetectable serum IL-6. The integration of a rapid, easy-to-use IL-6 test strip and a sensitivity-enhanced spectrometric reader makes this POC diagnostic device a promising tool for early recognition of patients who may develop respiratory failure requiring mechanical ventilation. The limit of detection was as low as 76.85 pg/ml and sensitive enough for clinical application as we previously mentioned (Lin et al., 2021) . IL-6 is an important cytokine that is rapidly induced over the course of infection (Ma et al., 2016) and could be used as a diagnostic aid to confirm infection in patients with systemic inflammatory response syndrome (Ma et al., 2016) . It has previously been found to be associated with disease severity and poor outcome for patients with sepsis (Song and Kellum, 2005; Ventetuolo and Levy, 2008; Song et al., 2019) . Elevated IL-6 is also known to be associated with CRS (Fajgenbaum and June 2020; Mangalmurti and Hunter, 2020) and induces a more severe disease and worse outcome for patients with COVID-19 (Jørgensen et al., 2020; Liu et al., 2020; Khodeir et al., 2021) . It could, thus, be used as a marker to stratify those with risk for severe disease. A meta-analysis study including 37 studies showed that mean IL-6 concentration was 55.3 and 37.3 pg/ml in patients with critical and severe COVID-19, respectively. (Leisman et al., 2020) , and 1,558.2 pg/ml in COVID-19 patients with hyperinflammatory acute respiratory distress syndrome (ARDS) (Leisman et al., 2020) . Three IL-6 diagnostic assays, Elecsys IL-6 (Roche Diagnostics, Basel, Switzerland) (Elecsys, 2021) , Access IL-6 assay (Beckman Coulter, Inc., Brea, California, US), (Beckmancoulter, 2021) , and ADVIA Centaur IL-6 assay (Siemens Healthcare Diagnostics, Inc., Erlangen, Germany) (Siemens Healthineers, 2021) were authorized for use by the US FDA by the end of April 2021. Each of these tests, in conjunction with clinical findings and the results of other laboratory testing, have been used to assist in identifying severe inflammatory response as a means of determining the risk of intubation with mechanical ventilation. However, these tests needed to be performed by well-trained technicians in a central laboratory with specific equipment. A POC diagnostic tool could be performed more easily and could shorten the time for diagnosis (Wang et al., 2020b) . In this study, we demonstrated a novel IL-6 detection POC diagnostic device that could detect those at risk of respiratory failure. Using a cutoff level of 76.85 pg/ml, we successfully differentiated COVID-19 patients with acute respiratory failure from those without acute respiratory failure. This study had several limitations. Although our test strip combined with a spectrum-based optical reader showed an excellent detection limit using the standard IL-6 compound, the sample size was small, and a further study including a larger sample size should be performed. Second, some patients received steroids or other immunosuppressants for COVID-19 treatment, which would influence serum IL-6 level. In addition, underlying comorbidities, such as malignancy and chronic lung disease, may have potentiated respiratory failure in those with COVID-19. Patients with these underlying diseases may develop respiratory failure even if they have low serum IL-6 levels. In conclusion, this study showed that an IL-6 LFA test strip combined with a spectrometric reader could provide a promising POC diagnostic approach for early recognition of COVID-19 patients who are at risk for acute respiratory failure. This would facilitate clinical risk assessment and stratification for COVID-19 patients, and subsequently ease burdens currently placed on global healthcare systems. The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation. The studies involving human participants were reviewed and approved by Tri-Service General Hospital, TSGH: IRB No. C202005067, Shuang Ho Hospital, SHH: TMU-JIRB No. N202004076, Taipei Hospital of Ministry of Health and Welfare, TH: TH-IRB-0020-0011. Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements. Access IL-6 Assay Infectious Diseases Society of America Guidelines on the Treatment and Management of Patients with COVID-19 IP-10 and MCP-1 as Biomarkers Associated with Disease Severity of COVID-19 An Inflammatory Cytokine Signature Predicts COVID-19 Severity and Survival Elecsys ® IL-6 Cytokine Storm Baseline Characteristics and Outcomes of 1591 Patients Infected with SARS-CoV-2 Admitted to ICUs of the Lombardy Region Clinical Features of Patients Infected with 2019 Novel Coronavirus in Wuhan Quantitative Spectrochip-Coupled Lateral Flow Immunoassay Demonstrates Clinical Potential for Overcoming Coronavirus Disease Increased Interleukin-6 and Macrophage Chemoattractant Protein-1 Are Associated with Respiratory Failure in COVID-19 Early Prediction Keys for COVID-19 Cases Progression: A Meta-Analysis Clinical Characteristics of Asymptomatic and Symptomatic Patients with Mild COVID-19. Clinical Microbiology and Infection High-performance and Scalable On-Chip Digital Fourier Transform Spectroscopy Cytokine Elevation in Severe and Critical COVID-19: a Rapid Systematic Review, Meta-Analysis, and Comparison with Other Inflammatory Syndromes Enzyme Immunoassay (EIA)/Enzyme-Linked Immunosorbent Assay (ELISA) A Paper-Based IL-6 Test Strip Coupled with a Spectrum-Based Optical Reader for Differentiating Influenza Severity in Children Prognostic Value of Interleukin-6, C-Reactive Protein, and Procalcitonin in Patients with COVID-19 Role of Interleukin-6 to Differentiate Sepsis from Non-infectious Systemic Inflammatory Response Syndrome Cytokine Storms: Understanding COVID-19 Cytokine Release Syndrome in Severe COVID-19 ADVIA Centaur IL6 Assay Diagnostic and Prognostic Value of Interleukin-6, Pentraxin 3, and Procalcitonin Levels Among Sepsis and Septic Shock Patients: a Prospective Controlled Study According to the Sepsis-3 Definitions Interleukin-6 Biomarkers: Diagnosis and Risk Assessment in Sepsis A Paper-Based Analytical Device for Analysis of Paraquat in Urine and its Validation with Optical-Based Approaches Current Diagnostic Tools for Coronaviruses-From Laboratory Diagnosis to POC Diagnosis for COVID-19 Coronavirus (COVID-19) Dashboard Risk Factors Associated with Acute Respiratory Distress Syndrome and Death in Patients with Coronavirus Disease Effect and Mechanism of Calpains on Pediatric Lobar Pneumonia Clinical Course and Risk Factors for Mortality of Adult Inpatients with COVID-19 in Wuhan, China: a Retrospective Cohort Study Frontiers in Bioengineering and Biotechnology | www.frontiersin.org Writing-review and editing: Y-CW Y-TL C-MC. All authors approved the final version of the manuscript. The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fbioe.2022.796996/ full#supplementary-material Conflict of Interest: C-YY was employed by Hygeia Touch Inc. and CH was employed by Spectrochip Inc.The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.