key: cord-0828417-vkkfvfol authors: Lu, Dingnan; Zhu, David Z.; Gan, Huihui; Yao, Zhiyuan; Fu, Qiang; Zhang, Xiaoqi title: Prospects and challenges of using electrochemical immunosensors as an alternative detection method for SARS-CoV-2 wastewater-based epidemiology date: 2021-03-05 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2021.146239 sha: 7ad4eb8074543341ffeadb2899ce537049dd869c doc_id: 828417 cord_uid: vkkfvfol Given its potential applications in confronting the COVID-19 pandemic, wastewater-based epidemiology (WBE) has attracted tremendous attention. Developing a fast, cost-effective, and practical method for SARS-CoV-2 detection in wastewater is of great significance to facilitate future WBE development. By now, the PCR-based approach serves as the reference method and “gold standard” to detect the virus in wastewater. However, we found a trend that the PCR-based method becomes almost an unshakable choice as more and more studies were published regarding SARS-CoV-2 WBE. Of note, the importance of exploring new, alternative approaches for SARS-CoV-2 detection in wastewater should not be underestimated. In this context, the prospect of using electrochemical immunosensors as the alternative detection method was investigated in this survey. Based on the previous efforts towards different virus immunoassay studies and newly published PCR-based COVD-19 WBE works, this survey provides new insights into the electrochemical immunoassay that have been widely adopted in body fluids virus detection, along with an extensive discussion of the detection mechanism, detection performance, past performances, current efforts, and potential challenges with wastewater detection. In the end, this survey concludes that using electrochemical immunosensors to analyze SARS-CoV-2 in wastewater samples quantitatively may have better feasibility and practicability than using the conventional PCR-based approach, especially when considering its fast detection, ease of miniaturization, and potential on-site measurement. Since 2019, a global pandemic (i.e., , caused by a novel coronavirus SARS-CoV-2, has posed a significant global health threat due to its relatively high mortality rate of 2.20% (WHO, 2021) and the great reproductive number of 2 to 2.5 (Bukkitgar et al., 2020) . As of February 13, 2021, more than 100,000,000 infected patients had been confirmed worldwide (WHO, 2021) . Besides the two main transmission routes (i.e., respiratory and contact (WHO, 2020) ), substantial evidence points out that the RNA of the SARS-CoV-2 virus could be found in the feces of an infected person (Holshue et al., 2020; Tang et al., 2020; Wang et al., 2020; WuGuo et al., 2020; Young et al., 2020) . Based on this observation, wastewater has attracted significant attention from environmental scientists and engineers because using wastewater-based epidemiology (WBE) may provide a much cheaper and more efficient means of tracking infectious agents in communities (Hamouda et al., 2020; Hart and Halden, 2020) . Recently, using WBE to track the magnitude and distribution of SARS-CoV-2 infection has been proposed and applied in many epidemic areas over the world , including Spain, India, Netherlands, Australia, Italy, Japan, Israel, France, and Singapore (AhmedAngel et al., 2020; Balboa et al., 2021; Bar Or et al., 2020; Green et al., 2020; materials from wastewater treatment plant (WWTP) influent samples. For example, in May 2020, Medema et al. (2020) published the earliest study to investigate if SARS-CoV-2 RNA is present in domestic wastewater of cities and a main airport during the early stages of the COVID-19 pandemic in the Netherlands. They reported that SARS-CoV-2 RNA was detected in WWTP Amersfoort on March 5 earlier than the report of the first two local clinical cases on March 11, suggesting the SARS-CoV-2 virus may preemptively circulate in the population before the local health surveillance system even noticed. Among all the WBE studies, it is worth noting that various viral concentration methods were adopted to concentrate the SARS-CoV-2 RNA, such as PEG-based separation, membrane filtration, ultrafiltration, and ultracentrifugation (AhmedBertsch et al., 2020) . Comparing with different concentration methods, all WBE studies conformably chose the reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) as their detection method. As of now, RT-qPCR is still the "gold standard" for the detection of low concentrations of viral particles in different matrices due to its relatively high sensitivity and excellent selectivity (Hamouda et al., 2020) . Nevertheless, it should be noted that using RT-qPCR technology to detect a specific type of virus in wastewater has some inherent limits, which would reduce the practical significance and hinder WBE's future development. For example, a PCR test typically requires 4-6 hours to complete, but the logistical requirement Tab 1. Comparison of the PCR-based detection method and the electrochemical immunosensor detection method. PCR-based detection A biosensor typically consists of a bioreceptor, a transducer, and a detector. The bioreceptor, such as antibodies and antigens, is designed to conjugate or react with the target analyte, thereby producing a specific biological change in the detecting environment (Li et al., 2010) . Afterward, the transducer can convert and transfer the biological change into a physicochemical signal through a quantifiable reaction and then allows a detector to collect the physicochemical signal (Khan et al., 2020) . Based on transducers' different principles, biosensors can be optical, fluorescent, surface plasmon resonant, piezoelectric, electrochemical, and magnetic, etc. (Khan et al., 2020) . Among all biosensing techniques, the electrochemical immunosensor is one of the most feasible options due to its ease of preparation and operation, rapid detection, low-cost sensor design, in situ detection of pathogens in various matrices, and potentially simultaneous detection of multiple targets (Cesewski and Johnson, 2020) . Moreover, unlike the PCR-based detection method, which requires an additional nucleic acid extraction step, an electrochemical immunoassay can directly convert ligand-based biological reaction into a quantifiable electrochemical signal, including voltammetric, impedimetric, amperometric, potentiometric, and conductometric (Silva et al., 2014; Silvestrini et al., 2015) . Regardless of the different signal types, the analyzing target of the electrochemical immunoassay is similar to that of other immunoassays, such as enzyme-linked immunosorbent assay (ELISA), which focuses on detecting either a species-specific antigen from a virus itself or an antibody against the corresponding antigen derived from a host's immune system (Mao et al., 2021) . According to several reviews, the conventional approaches for developing electrochemical immunosensors can be categorized J o u r n a l P r e -p r o o f Journal Pre-proof under two headings, namely the label-free format and the label-based format (sandwich-type) (see Fig. 1 ) (Khan et al., 2020; Ricci et al., 2012; Schuurs and Van Weemen, 2006) . The fundamental mechanism of using a label-free electrochemical immunosensor to detect viral antigen or antibody is that the binding of the immobilized recognition element and the target analyte could modify the electrode surface with some bulky sized antibody-antigen immunocomplexes and therefore alter the electrochemical signal of a standardized redox couple, which is almost always the pair of potassium ferricyanide/ferrocyanide (Fe(CN) 6 +3 / +4 ) (Bukkitgar et al., 2020; Ricci et al., 2012; Schuurs and Van Weemen, 2006) . Of note, when J o u r n a l P r e -p r o o f Journal Pre-proof using the label-free format, a relatively high background signal obtained from the preemptively added redox couple is required for testing a sample without any analyte. The detected signal will then decrease in proportion to the increase of an analyte's concentration due to the electrode surface covered by a specific immunocomplex. As shown in Fig. 1 , two approaches could be used when preparing a label-free electrochemical immunosensor, and the main difference lies in selecting the immobilized biological recognition element (i.e., antigens or antibodies). Unlike the label-based electrochemical immunosensor (i.e., sandwich-type), the label-free electrochemical immunosensor requires no addition of an enzyme (or inorganic label) conjugated secondary antibody but, in some cases, relies on the competition between the target analyte and immobilized recognition element, thereby causing it to be sometimes named the "competitive approach" method in publications (Bukkitgar et al., 2020; Khan et al., 2020; Pei et al., 2013; Tang and Tang, 2015) . For example, when detecting a specific type of virus through antigen assay, instead of immobilizing the corresponding antibody as the recognition element, the competitive approach (label-free) immunosensor could choose to immobilize the target antigen and then spike a fixed concentration of antibodies to initiate a competitive effect between the immobilized antigens and target antigens, thereby changing the preset electrochemical signal in a testing solution. Because of the elimination of preparing a labeled secondary antibody, the label-free format is a relatively low-cost and straightforward technology developed to diagnose many J o u r n a l P r e -p r o o f As per the nature of a label-free electrochemical immunosensor, the main difficulty is precisely aligning and orienting the biological recognition element (i.e., immobilized antibodies or antigens) on an electrode surface during the immobilization step (Khan et al., 2020) . More specifically, when dealing with immobilization, the recognition element's alignment not only affects the efficiency of ligand-based conjugation but also significantly alters the working electrode surface, which may result in the overly-passivated electrode surface and consequently degradation in the sensitivity of detection. In 2019, Layqah and Eissa (2019) to immobilize the recognition element of the spike protein S1. Similar immobilization procedures were previously reported using solid gold electrodes to create the SAMs with a linkage agent (e.g., cysteamine) containing a gold-affinity thiol at one end and a functional group (e.g., amine) for subsequent attachment of recognition element at the other end (Escamilla-Gomez et al., 2008; Feng et al., 2008; Ricci et al., 2012) . Compared with traditional solid gold electrodes, Layqah and Eissa's (2019) immobilization strategy no only allows the formation of SAMs through thiol-gold chemistry in a highly ordered way but also enhance the voltammetric response over the redox couple through the electrodeposited AuNPs. Immobilization of MERS-CoV recombinant spike protein S1 using thiol-gold chemistry (image adapted from Layqah and Eissa (2019)). At the core of the sandwich-type electrochemical immunosensor is the adaptation of the ELISA assay to an electrochemical platform (Ricci et al., 2012) . Several crucial factors J o u r n a l P r e -p r o o f require more thorough consideration and analysis because of the different transducers mechanisms used in an optical ELISA and a sandwich electrochemical immunosensor. The number one key factor lies in selecting an efficient electroactive label to indicate the antigen-antibody reaction (Pei et al., 2013) . According to several recent reviews, two labeling strategies could be conceived, namely the enzyme label and the nanoparticle tag, when designing a sandwich-type electrochemical immunosensor (Pei et al., 2013; Ricci et al., 2012) . A first strategy typically in which the electrochemical signal is derived from the enzymatic reaction between the labeled enzyme (e.g., alkaline phosphatase) on the secondary antibody and the corresponding enzymatic substrate (e.g., 1-naphthyl phosphate) in the solution (Centi et al., 2010; Pandey et al., 2012; Zani et al., 2011) . A second one, using novel nanoparticle tags, such as copper, silver, and Fe 3 O 4 nanoparticles, to first attach to the secondary antibody and then react with a specifically designed electrochemical substrate. The nanomaterial tag is a relatively new technology that has been recently reported in some electrochemical immunoassay studies, which provides a whole new perspective to amplify the electrochemical signal of a sandwich-type immunosensor (Ahmadi et al., 2014; Huang et al., 2016; Zhang et al., 2014) . Unlike the label-free approach, an obvious advantage of the sandwich-type electrochemical immunosensor is that the derived electrochemical response originates directly from the ligand-based biological reaction and does not require a redox couple to indicate the binding of the recognition element and analyte indirectly. However, it should be noted that the preparation of a specific labeled secondary antibody could significantly increase the total workload of developing a sandwich-type immunoassay. For example, the following study is a representative example of how novel nanocomposite J o u r n a l P r e -p r o o f material can significantly improve the voltammetric response of a sandwich-type electrochemical immunosensor while increasing the difficulty in preparation and detection. Zhang et al. (2014) proposed using dual-functional copper-doped titanium dioxide nanoparticle (Cu@TiO 2 ) as signal amplification tag (a comparable technology to the conventional enzymatic label) to develop an electrochemical immunoassay using a carboxyl functionalized graphene oxide (CFGO) modified glassy carbon electrode to detect human IgG in serum samples (see Fig. 3 ). The dual-functional characteristic allows the transducer to freely switch between two electrochemical signals, namely, the square wave voltammetric response derived from the Cu-Cu 2+ oxidation current and the amperometric response due to the TiO 2 catalyzed hydrogen peroxide (H 2 O 2 ) reaction. For the square wave voltammetric method, the linear response range is 0.1 pg.mL -1 to 100 ng.mL -1 , with a limit of detection of 0.052 pg.mL -1 . Meanwhile, the amperometric method obtained a linear range over 0.01 pg.mL -1 to 100 ng.mL -1 , with a limit of detection of 0.0043 pg.mL -1 . In summary, the developed Cu@TiO 2 label did demonstrate excellent detection performance and incredible versatility, but the lengthy preparation process, particularly of which designing and fabricating the Ab1-CFGO modified electrode and the Cu@TiO 2 labeled Ab2 secondary antibody, is still a sore point and does not seem currently feasible for mass production. 2014)). Despite the bright future ahead of the nanomaterial tag approach, the conventional enzyme label approach still represents the mainstream of developing a sandwich-type immunosensor, particularly when the priority comes down to practical application like clinical diagnosis. For example, the selection of lactate oxidase as the enzyme label in a clinical immunosensor development was reported to be used in detecting carcinoma antigen 125 (CA125) in human serum (Samadi Pakchin et al., 2018) . Accordingly, hydrogen peroxide was added into the testing solution as a substrate to demonstrate the enzymatic reaction activity exerted by the lactate oxidase label. Although they used nanocomposites (i.e., gold nanoparticles, multiwall carbon nanotube, and graphene oxide) to enhance the electrochemical platform's sensing performance, the fundamental mechanisms of how the enzymatic reaction was trigged and how the biochemical signal was transduced fell in line with the classic enzyme label design philosophy (see Fig. 4 ). In summary, the sandwich-type electrochemical immunosensor is capable of adapting the conventional optical ELISA to an electrochemical platform with a higher detection sensitivity and better signal-to-interference performance (Pei et al., 2013; Ricci et al., 2012) . However, it should be noted that the sandwich-type immunosensor relies not only on the labeling strategy but also significantly associated with the recognition element immobilization approach, thereby requiring a more comprehensive fabrication process than the label-free format. Consequently, when conceiving a new electrochemical immunoassay, the choice of either using a label-free or sandwich-type type must be carefully weighed to take into account the need of following mass production. Developing fast, reliable, and point-of-care detection technology is one of the most crucial practices to combat global pandemic such as SARS-COV-2. In recent months, there are many research groups worldwide in different fields that aspire to use available resources as effectively as possible to develop novel detection methods for the SARS-COV-2 clinical J o u r n a l P r e -p r o o f Journal Pre-proof diagnosis. For example, one of the most recent SARS-COV-2 electrochemical immunosensor, reported by Fabiani et al. (2021) , was developed and aimed to detect Spike (S1) and Nucleocapsid (N) protein in saliva using magnetic beads (MBs) integrated sandwich-type immunosensor. In their study, the secondary antibody is labeled with the typically used alkaline phosphates (AP) for the enzymatic reaction of 1-naphthyl phosphate to 1-naphthol. As can be seen from the detection mechanism, the authors chose a well-proven approach when conceiving and performing the immunoassay, which is probably due to the urgent need for an immunological method to conduct practical application. This section will focus primarily on the recent electrochemical immunosensor built to detect the virus (e.g., SARS-CoV-2, MERS, HCoV, and influenza) in various testing mediums (e.g., serum, saliva, and nasal fluids), especially their design principles and practical aspects. As shown in Tab. 2, six recent electrochemical immunosensors, including three newly reported SARS-CoV-2 detection studies (Eissa and Zourob, 2021; Fabiani et al., 2021; Rashed et al., 2021) , two previously developed influenza detection studies (Tang and Tang, 2015; Zhou et al., 2013) , and one MERS-CoV and HCoV codetection study (Layqah and Eissa, 2019) . Despite the different detected viruses, all the listed studies, in fact, can still be categorized under two main principles: label-free and sandwich-type. When comparing the limit of detection (LoD), the enzymatic labeled (i.e., sandwich-type) immunosensors did not show superior performance as expected, which is probably due to the use of MBs during the process of immunological chains (Fabiani et al., 2021; Zhou et al., 2013) . It is worth mentioning that the use of MBs could overcome many obstacles in the conventional Journal Pre-proof sandwich-type immunosensors, such as the possibility of passivation of the electrode surface due to the lengthy immunological steps and the confinement of the total recognition elements upon the electrode surface because of the limited space of a working electrode (Ricci et al., 2012) . However, using MBs as support for the immobilization of recognition elements could bring in an obvious drawback that the secondary antibody is not in direct contact with the electrode surface, thereby limiting the overall detection sensitivity. In contrast, some label-free immunosensors demonstrated surprisingly high sensitivity, with LoDs being thousands of times lower than the two sandwich-type studies (Eissa and Zourob, 2021; Jarocka et al., 2016; Layqah and Eissa, 2019) . As a result, due to the relatively simple and straightforward preparation steps, it is reasonable to give priority to the label-free immunosensor when developing a new electrochemical immunosensor for virus detection. Moreover, it can be found that, in most cases, the actual sampling sizes are below the milliliter level (e.g., 10 and 50 μL), and the tested samples are relatively homogeneous and predictable, such as serum and saliva. Hence, before developing a new electrochemical immunosensor for SARS-COV-2 WBE, it is necessary to come up with some countermeasures to be taken when handling wastewater samples with the characters of large sample volume, low virus concentration, and overly-complex testing matrix. The main challenges of adapting electrochemical immunoassay for WBE will be surveyed in more detail in the following section. Journal Pre-proof Tab 2. Development principles and practical aspects of recently reported electrochemical immunosensors for the detection of different types of viruses. As mentioned above, using electrochemical immunosensors to detect the presence of a specific type of virus in wastewater samples is more challenging than in body fluid samples. It can be primarily ascribed to the complex matrix of a typical wastewater sample and its relatively low virus concentration (Pilevar et al., 2020) . Consequently, it is necessary to pretreat, concentrate, or extract the target virion from a wastewater sample before conducting the subsequent immunoassay in a comparatively small-volume test medium. As mentioned, in the recent SARS-COV-2 WBE cases, all of the studies selected RT-qPCR as their virus detection approach. While the PCR-based methods are still the "gold standard" as of now and can offer high sensitivity due to the target genes amplification step, its lengthy processing time, varieties of required internal/external references and kits, and susceptibility to environmental inhibitors together are likely to create bottlenecks in the future development of WBE. In contrast, the electrochemical immunosensor can provide a result within the shortest possible time of 15 minutes and only require a buffer solution for electrochemical reactions to take place (Pilevar et al., 2020) . Based on the recent review by Lu et al. (2020) , almost all published PCR-based SARS-COV-2 WBE studies, to a certain extent, had adopted pretreatment and concentration processes before conducting the PCR test. A relatively low sensitive method could be compensated in part by having a large-volume initial sample and then condensing it into a much smaller final sample through one or multiple concentration steps. Therefore, we believe that if employing pretreatment and concentration steps is a must-have in both PCR-based and immunosensor-based virus detection in wastewater samples, their performance's differences J o u r n a l P r e -p r o o f Journal Pre-proof in terms of the detection sensitivity might not be as significant as we commonly understood. Consequently, choosing appropriate pretreatment and concentration methods during the sample preparation is of vital importance to overcome the challenges regarding using electrochemical immunosensors in SARS-COV-2 WBE. A municipal wastewater sample matrix usually consists of human excrete (i.e., feces and urine), shower/bath water, food waste, household maintenance products, along with a wide variety of trace amounts of organic and inorganic compounds. Some important wastewater constituents, which can potentially affect SARS-CoV-2 detection in wastewater samples, are listed in Tab. 3. For instance, suspended solids, captured by a filter with a nominal pore-size varying from 0.45 μm to about 2.0 μm (Tchobanoglous, 2014) , can attract small virus particles suspended in the wastewater sample (WHO, 2003) . Therefore, employing a relatively large pore-size filter (e.g., 1.0 μm) or relatively slow-speed centrifugation (1,000 × g, 5 min) step to pretreat a wastewater sample may eventually cause a considerable loss of the target virus particles. To avoid such losing, WuZhang et al. (2020) retained the pre-centrifuged pellet and simultaneously eluted it with the subsequent PEG precipitated layer. The presence of biodegradable organics is another factor that can potentially affect the virus concentration efficiency. For example, using electrostatically charged membranes to adsorb viruses from the wastewater can be subject to a significant reduction of virus recovery efficiency due to the presence of organic matter, which can result in a preferential attachment to the charged filters and raise the risk of the membrane-clog situation . For electrochemical immunoassay, crossing-reacting species that may exist in a test sample are the most intractable problem, resulting in both over-or-under-estimation of the detected virus J o u r n a l P r e -p r o o f concentration (Schuurs and Van Weemen, 2006; Tate and Ward, 2004) . It should be noted that clean up all potential crossing-reacting species in a given wastewater sample, no matter how a comprehensive pretreatment is adopted, is neither feasible nor practical. Before preparing an electrochemical immunosensor, selecting a pair of antibody-antigen that contains high specificity is a simple, affordable, and standard approach to solve the problem of crossing-reacting species (Tate and Ward, 2004) . Moreover, carrying out a preemptive blocking test in the antigen-spiked wastewater matrix to validate the specificity before performing the actual test can directly demonstrate the proposed immunoassay's feasibility (Guttman-Bass et al., 1987; Morinet et al., 1984) . For example, Guttman-Bass et al. (1987) evaluated a commercial immunoassay's specificity by incubating the spiked SA-11 rotavirus and rotavirus antiserum for 1 hr at 37 o C before the actual test in the wastewater. To the best of our knowledge, there is no electrochemical immunosensor currently developed to detect the SARS-CoV-2 antigen in the wastewater sample specifically. However, after a comprehensive review, we found several previously reported studies that focused on detecting viral antigens in wastewater samples using immunological-based approaches. As shown in Tab. 4, all these studies adopted preconcentration methods before the subsequent immunoassays, and all of them successfully detected the target viral antigens from raw sewage samples. These three studies chose three different technologies in terms of the preconcentration methods, including the adsorption-elution method (Guttman-Bass et al., 1987) , the filtration method (Palmer et al., 1993) , and the ultracentrifugation method (Calgua et al., 2011) . It is worth noting that two of these studies were published relatively early, and J o u r n a l P r e -p r o o f Journal Pre-proof the sensitivities of both optical immunoassays were considerably lower than today's nanomaterials-integrated immunosensors. Collectively, based on all the information that had been found, it is our confident expectation that the development of a feasible electrochemical immunosensor as the alternative detection approach with an effective concentration method could achieve a fast, sensitive, and cost-effective detection of SARS-CoV-2 in the wastewater, thereby providing critical information for analyzing the prevalence of SARS-COV-2 in a community. Tab. 3. Constituents of concern for virus detection in wastewater. Suspended solids A significant cause of the development of sludge deposits in the sewage system and may lead to the electrostatic attachment of viruses on suspended solids (Tchobanoglous, 2014) . Biodegradable organics (proteins, carbohydrates, and fats) Measured in BOD/COD, the presence can significantly reduce virus concentration efficiency when using the electrostatically charged membrane method due to a preferential attachment of dissolved organic molecules over virus particles (Fout et al., 2015) . Other pathogens (virus, bacteria, protozoa) Other seasonal, infectious diseases with similar symptoms may be transmitted with SARS-CoV-2 simultaneously; the cross-react species may result in the over-or under-estimation of the target virus (Tate and Ward, 2004) . nutrients) The essential nutrients for biofilm growth in the sewage system, the resulted biofilm can be associated with the confinement, retardation, and decay of virus particles during transport in sewage pipes Tchobanoglous, 2014) . Heavy metals (Cr, As, Pb, Hg, etc.) Highly toxic to biological activities when having a high concentration; can lead to antigen denaturation (Tchobanoglous, 2014) . Two available approaches can be referenced regarding the electrochemical immunosensor development: the label-free format and the label-based (sandwich-type) format. Comparing both approaches, the sandwich-type format, in general, is believed to be capable of delivering a better sensitivity (Pei et al., 2013) . However, we found that label-free immunosensors sometimes can offer better sensitivity when detecting viruses through the antigens-antibodies reaction (Jarocka et al., 2016; Layqah and Eissa, 2019) . This phenomenon is in part associated with the rapidly developed nanomaterials technology, which endows the label-free electrode surface with significantly greater sensing capability, while the sensitivity of the J o u r n a l P r e -p r o o f Journal Pre-proof sandwich-type format is subject to the activity of the labeled enzymatic reaction. Besides, the relatively sizeable virus particle, compared with other conventional immunological analytes such as human thyroglobulin (Coscia et al., 2020) , can result in a more remarkable electrode surface change, thereby favoring the detection performance of the label-free format. Moreover, the preparation of a specific labeled secondary antibody could considerably increase the total workload of developing a sandwich-type immunosensor. As of now, two electrochemical immunosensors have been developed to detect SARS-CoV-2 in human body fluids (i.e., saliva and serum), and both showed promising performance (Fabiani et al., 2021; Rashed et al., 2021) . It should be noted that similar to PCR-based studies, the adaptation of clinical diagnosis to wastewater detection requires additional pretreatment and concentration steps to reduce the wastewater matrix's complexity and elevate the diluted virus concentration. Thanks to the numerous reported PCR-based SARS-COV-2 studies and a few early published other virus immunoassays in wastewater, it is not difficult to adopt or refine an existing pretreatment and concentration steps prior to an electrochemical immunoassay based on substantial evidence and reliable results, see Fig. 5 . WBE has a proven track record of being implemented as a large-scale surveillance tool to combat infectious diseases, such as poliovirus (Asghar et al., 2014; Ikner et al., 2012) . It now holds an excellent promise for surveillance of the SARS-COV-2 prevalence at the community level. Yet, the SARS-COV-2 WBE is still in its infancy and remains only a preliminary tested tool in many scientific research articles. In part, this situation is associated with the RT-qPCR assay, which relies on the amplification cycle to achieve the goal of virus quantification. Due to the high variability of wastewater matrix and different concentration methods adopted, the J o u r n a l P r e -p r o o f Journal Pre-proof amplification step could be subject to inhibition and render unreproducible assay performance. For the electrochemical immunosensor, although there are constituents in wastewater that may trigger the non-specific immunological reaction, the mechanism in terms of quantitative measurement is more straightforward. Collectively, we believe the electrochemical immunosensor method has a great potential to cut an outstanding figure regarding the SARS-COV-2 WBE. In the end, based on the previous efforts towards different virus immunoassay studies and new PCR-based COVD-19 WBE works, we present the following concise conclusions for those audiences who aspire to develop new detection or diagnosis methods to protect human society from further damage brought on by the SARS-COV-2 pandemic: 1. Due to the nature of the electrochemical immunosensor, it is possible to demonstrate better feasibility and practicability than the PCR-based approach, especially when considering its fast detection, ease of miniaturization, and potential on-site measurement. 2. Developing electrochemical immunosensors to detect viral antigens' presence has been done primarily in the body fluids, such as nasal fluid and saliva. To the best of our knowledge, only three early works tried immunological-based methods to detect viruses in raw wastewater samples. 3. Two commonly used strategies can be referenced when developing a new electrochemical immunosensor: the label-free and the sandwich-type format. Based J o u r n a l P r e -p r o o f Journal Pre-proof on past performance, the label-free format is relatively straightforward to be prepared. It shows comparable performance as the sandwich-type format in virus detection, sometimes even more sensitive than the sandwich-type immunosensor. No matter what method is chosen for virus detection, it is necessary to pretreat and concentrate the wastewater samples due to the matrix's complexity and the diluted virus concentration. Various pretreatment and concentration methods, such as PEG precipitation, electrostatic membrane adsorption, and ultracentrifugation, are available to be selected, refined, and adapted to electrochemical immunoassay. 5. It is crucial to give equal attention to the detection method's sensitivity and practicability to facilitate future development of SARS-CoV-2 detection in wastewater. Flow chart of the SARS-COV-2 measurement with the proposed electrochemical immunoassay approach as an alternative detection method for future WBE. An electrochemical immunosensor for digoxin using core-shell gold coated magnetic nanoparticles as labels First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community Comparison of virus concentration methods for the RT-qPCR-based recovery of murine hepatitis virus, a surrogate for SARS-CoV-2 from untreated wastewater Environmental surveillance for polioviruses in the Global Polio Eradication Initiative The fate of SARS-COV-2 in WWTPS points out the sludge line as a suitable spot for detection of COVID-19 Regressing SARS-CoV-2 sewage measurements onto COVID-19 burden in the population: a proof-of-concept for quantitative environmental surveillance Electrochemical investigations for COVID-19 detection-A comparison with other viral detection methods Detection and quantitation of infectious human adenoviruses and JC polyomaviruses in water by immunofluorescence assay The structure of human thyroglobulin Development of a Low-Cost Cotton-Tipped Electrochemical Immunosensor for the Detection of SARS-CoV-2 Immunosensor for the determination of Staphylococcus aureus using a tyrosinase-mercaptopropionic acid modified electrode as an amperometric transducer Magnetic beads combined with carbon black-based screen-printed electrodes for COVID-19: A reliable and miniaturized electrochemical immunosensor for SARS-CoV-2 detection in saliva Electrochemical immunosensor with aptamer-based enzymatic amplification EPA Method 1615. Measurement of enterovirus and norovirus occurrence in water by culture and RT-qPCR. I. Collection of virus samples Quantification of SARS-CoV-2 and cross-assembly phage (crAssphage) from wastewater to monitor coronavirus transmission within communities Comparison of methods for rotavirus detection in water and results of a survey of Jerusalem wastewater Simple and effective label free electrochemical immunosensor for Fig mosaic virus detection Wastewater surveillance for SARS-CoV-2: Lessons learnt from recent studies to define future applications First environmental surveillance for the presence of SARS-CoV-2 RNA in wastewater and river water in Japan Silver nanoparticles coated graphene electrochemical sensor for the ultrasensitive analysis of avian influenza virus H7 Concentration and recovery of viruses from water: a comprehensive review An electrochemical immunosensor based on a 4,4′-thiobisbenzenethiol self-assembled monolayer for the detection of hemagglutinin from avian influenza virus H5N1 Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art First Data-Set on SARS-CoV-2 Detection for Istanbul Wastewaters in Turkey First proof of the capability of wastewater surveillance for COVID-19 in India through detection of genetic material of SARS-CoV-2 (reprint at First detection of SARS-CoV-2 in untreated wastewaters in Italy An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes Gold nanoparticles modified electrode via a mercapto-diazoaminobenzene monolayer and its development in DNA electrochemical biosensor Primary concentration -The critical step in implementing the wastewater based epidemiology for the COVID-19 pandemic: A mini-review Biosensors for wastewater-based epidemiology for monitoring public health Label-free electrochemical immunosensor for detection of tumor necrosis factor α based on fullerene-functionalized carbon nanotubes/ionic liquid Presence of SARS-Coronavirus-2 RNA in Sewage and Correlation with Reported COVID-19 Prevalence in the Early Stage of the Epidemic in The Netherlands Comparison of six methods for detecting human rotavirus in J o u r n a l P r e -p r o o f stools Temporal detection and phylogenetic assessment of SARS-CoV-2 in municipal wastewater Detection of Legionella species in sewage and ocean water by polymerase chain reaction, direct fluorescent-antibody, and plate culture methods Nanoporous gold as a solid support for protein immobilization and development of an electrochemical immunoassay for prostate specific antigen and carcinoembryonic antigen SARS-CoV-2 RNA concentrations in primary municipal sewage sludge as a leading indicator of COVID-19 outbreak dynamics Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review Recent advances in biosensors for detecting viruses in water and wastewater Dual-Functional Plasmonic Photothermal Biosensors for Highly Accurate Severe Acute Respiratory Syndrome Coronavirus 2 Detection SARS-CoV-2 RNA in wastewater anticipated COVID-19 occurrence in a low prevalence area Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector A review of experimental aspects of electrochemical immunosensors Presence and Vitality of SARS-CoV-2 Virus inWastewaters and Rivers Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor Detection of SARs-CoV-2 in wastewater, using the existing environmental surveillance network: An epidemiological gateway to an early warning for COVID-19 in communities First detection of SARS-CoV-2 RNA in wastewater in North America: A study in Louisiana Fast, portable tests come online to curb coronavirus pandemic A thiophene-modified screen printed electrode for detection of dengue virus NS1 protein Detection of DNA Hybridization by Methylene Blue Electrochemistry at Activated Nanoelectrode Ensembles Detection of Novel Coronavirus by RT-PCR in Stool Specimen from Asymptomatic Child Non-enzymatic electrochemical immunoassay using noble metal nanoparticles: a review Interferences in immunoassay Wastewater Engineering: Treatment and Resource Recovery-Chap. 2 Detection of SARS-CoV-2 in Different Types of Clinical Specimens Guidelines for environmental surveillance of poliovirus circulation Water, sanitation, hygiene, and waste management for the COVID-19 virus: interim guidance Prolonged presence of SARS-CoV-2 viral RNA in faecal samples Evaluation of lockdown impact on SARS-CoV-2 dynamics through viral genome quantification in Paris wastewaters Singapore Novel Coronavirus Outbreak Research T. Epidemiologic Features and Clinical Course of Patients Infected With SARS-CoV-2 in A New Electrochemical Multiplexed Assay for PSA Cancer Marker Detection Copper-doped titanium dioxide nanoparticles as dual-functional labels for fabrication of electrochemical immunosensors Ultrasensitive supersandwich-type electrochemical sensor for SARS-CoV-2 from the infected COVID-19 patients using a smartphone A magnetic bead-based bienzymatic electrochemical immunosensor for determination of H9N2 avian influenza virus The authors would like to acknowledge the National Natural Science Foundation of China (52070103) for the support of this work. contributed reviewing. DL and DZ contributed corresponding. All authors had final approval of the article. The authors declare no competing interests.