key: cord-0828012-op2r9lz0 authors: Panahi, Abbas; Sadighbayan, Deniz; Forouhi, Saghi; Ghafar-Zadeh, Ebrahim title: Recent Advances of Field-Effect Transistor Technology for Infectious Diseases date: 2021-04-02 journal: Biosensors (Basel) DOI: 10.3390/bios11040103 sha: 8dd59592278ad2651912766a7d84252caad61eec doc_id: 828012 cord_uid: op2r9lz0 Field-effect transistor (FET) biosensors have been intensively researched toward label-free biomolecule sensing for different disease screening applications. High sensitivity, incredible miniaturization capability, promising extremely low minimum limit of detection (LoD) at the molecular level, integration with complementary metal oxide semiconductor (CMOS) technology and last but not least label-free operation were amongst the predominant motives for highlighting these sensors in the biosensor community. Although there are various diseases targeted by FET sensors for detection, infectious diseases are still the most demanding sector that needs higher precision in detection and integration for the realization of the diagnosis at the point of care (PoC). The COVID-19 pandemic, nevertheless, was an example of the escalated situation in terms of worldwide desperate need for fast, specific and reliable home test PoC devices for the timely screening of huge numbers of people to restrict the disease from further spread. This need spawned a wave of innovative approaches for early detection of COVID-19 antibodies in human swab or blood amongst which the FET biosensing gained much more attention due to their extraordinary LoD down to femtomolar (fM) with the comparatively faster response time. As the FET sensors are promising novel PoC devices with application in early diagnosis of various diseases and especially infectious diseases, in this research, we have reviewed the recent progress on developing FET sensors for infectious diseases diagnosis accompanied with a thorough discussion on the structure of Chem/BioFET sensors and the readout circuitry for output signal processing. This approach would help engineers and biologists to gain enough knowledge to initiate their design for accelerated innovations in response to the need for more efficient management of infectious diseases like COVID-19. The recent decade has witnessed significant advancements in the detection and treatment of different diseases that have improved the level of human health globally. However, the COVID-19 pandemic taught us that we are not very well prepared for early diagnostic and management of infectious diseases at the time of pandemics for controlling the further spread of disease [1] . There are many hurdles in front of fast and resourceful management of infectious disease in the time of emergency like what happened during COVID-19 pandemics. The most noteworthy problems associated with current medical procedures for controlling infectious diseases are drug resistance evolution of pathogens and also the possibility of the appearance of new genetically developed agents, which might spread much faster than the previous virus case, as we saw an example of that during COVID-19 pandemic during which a newly evolved version of the virus was spotted in England where α shows a dimensionless sensitivity parameter. The value of α varies between 0 and 1, which highly depends on the intrinsic buffer capacity and the differential capacitance. K is Boltzman constant, and T is the absolute temperature. Furthermore, stands for the surface charge (charge on oxide surface and in general the interface between surface and electrolyte), βint is the ionic capacity and Cdif denotes the differential capacitance. The surface potential will be changed when a small variation takes place in the electrolyte ion concentration that could be the result of either a chemical reaction in a biological sample or simply the existence of charged molecules in the solution. Generally, adding a specific concentration of an analyte varies the pH of the solution, which can be correlated to the potential of the surface through Equation (4) . This potential affects the source-drain current in the conduction channel. So, the threshold voltage of an ISFET is [31] : where γ is a pH-independent grouping of chemical potentials, Vth = kT/q denotes thermal voltage, and Vt(MOS) is the threshold voltage of a conventional MOSFET. Different operational regions of the ISFETs can be used for sensing including (1) Triode (or linear region), (2) strong inversion (or saturation), (3) weak inversion (or subthreshold) and (4) velocity saturation. As aforementioned, Equation (1) describes the drain current in the triode region. Drain current of a saturated ISFET (VDS > VGS − Vt(ISFET)) is obtained by: where λ is the channel length modulation factor. If ID and VDS both are held constant, VGS will adjust to compensate for any changes in Vt(ISFET). By assuming a zero bulk-source voltage and VDS > 4Vth, the operation of an ISFET in weak inversion region can be described by [31] : where I0 is a positive constant current and n stands for the subthreshold slope parameter. In the velocity saturation region, the operation of the device can be expressed by [32] : The potential at the oxide layer and solution interface arises then will be decreased gradually to the solution potential. Adding the sample would manipulate this potential curve influencing the charge transport inside the silicon channel. There are three main capacitances involved in the system consisting of the oxide, channel depletion capacitance, and the solution double layer (C DL ). Biosensors 2021, 11, x FOR PEER REVIEW 6 of 50 where vsat and VD,sat, respectively, stand for the saturated carrier velocity and the point when the drain current saturates. These principles work for semiconductor-oxide-electrolyte Chem/BioFET regardless of their geometries and channel-gates arrangement. However, the principle might not be applied to some specific Chem/BioFETs, which are working based on the sensing properties of nanomaterials like graphene or carbon nanotubes (CNTs). This fact stems from the fact that the ion complexation on these surfaces might not follow the site-bonding theory. Mathematical modeling of the molecular interaction at the surface (oxide or nitride) is extremely difficult, thus prediction of surface potential will be impossible like what sitebonding theory provides. However, in terms of modeling the interaction in BioFET surface complex systems, recently atomistic molecular dynamics simulation has been recruited to analyze the ion complexation on the surface and measure the surface potential on the channel [33] [34] [35] . State-of-the-art molecular analysis has empowered researchers to get insight into the molecular interactions at the channel surface and estimate the doublelayer capacitance considering the interaction of nanomaterials, oxide, ionic solution and proteins on the surface, which is not practical possible with current models. Figure 2a -c represents the surface potential in a very complex system containing ionic solutions. Unravelling the exact physical phenomena taking place at the semiconductor-oxideelectrolyte is of imperative importance when it comes to fabricating BioFET sensors more efficiently. Furthermore, this understanding becomes more important when we scale down to the nano BioFET structures, where the ions and molecular interactions dominate the electron conduction in the channel. This in-depth study would also enable us to decipher and control unexpected and intrinsic interfacial noises. Significant advancements have been made on this matter, which has considerably assisted the multi-scale design of ISFETs and the discovery of novel BioFET sensing materials. As the fabrication of these FETs progressed well, the development of theories to explain the physical phenomena was emerging in parallel to explain noises and some fabrication challenges [26, 27] . The type of ISFETs on which a layer of the ion-sensitive membrane was in interaction with solution have been theorized perfectly. However, the direct interaction of electrolyte with oxide layer was not developed at the same pace [28] . As it is shown in Figure 1 , due to the interaction of ions and the oxide layer, the double-layer capacitance will be created (C DL ) on the proximity of oxide. The oxide layer capacitance, which is a built-in characteristic of this layer, will appear on top of the channel. The channel itself due to the depletion effect of the adsorbed charges on the surface will create another capacitor that will be modulated by the surface charge density and the electron/holes transport in the channel. Charge effects on the surface of the oxide layer would result in the source-drain current, which can be mathematically expressed as follows (we encourage readers to study an in-depth analysis in [28] ): Equation (1) shows the current in the channel when the sensor is exposed to an electrolyte with varying potential and works in the linear operational region (V DS < V GS − V t(ISFET) ). In this equation, the parameters are as follow: µ stands for average mobility in the channel; W and L are the width and the length of the gate, respectively; V DS and V GS are the drain-source voltage and the gate-source voltage, respectively; C ox identifies the capacitance of the gate oxide. V t(ISFET) is the threshold voltage of the ISFET, which can be expressed as follows: where E ref identifies the potential of the reference electrode; Ψ 0 is the insulator-electrolyte potential; χ sol stands for the surface dipole potential of the solution; φ Si is silicon electron work function; q denotes the elementary charge; Q ox , Q ss and Q B are the charges in the oxide, charges in surface states and interface states and the depletion charge, respectively; and φ f is the potential difference between the Fermi levels of doped and intrinsic silicon. All of the parameters in Equations (1) and (2) are constant values except Ψ 0 , which shows the effect of surface potential on the oxide layer and affects V t(BioFET) . This will be changed by the ionic solution and biomolecular content of the solution that directly influences the current in the channel. Through mathematical modelling and using sitebonding theory (please read [29] , and [30] for detailed information) the potential of the surface could be related to the pH of the bulk solution. The corresponding equations for more insight are as follow: where α shows a dimensionless sensitivity parameter. The value of α varies between 0 and 1, which highly depends on the intrinsic buffer capacity and the differential capacitance. K is Boltzman constant, and T is the absolute temperature. Furthermore, σ 0 stands for the surface charge (charge on oxide surface and in general the interface between surface and electrolyte), β int is the ionic capacity and C dif denotes the differential capacitance. The surface potential will be changed when a small variation takes place in the electrolyte ion concentration that could be the result of either a chemical reaction in a biological sample or simply the existence of charged molecules in the solution. Generally, adding a specific concentration of an analyte varies the pH of the solution, which can be correlated to the potential of the surface through Equation (4) . This potential affects the source-drain current in the conduction channel. So, the threshold voltage of an ISFET is [31] : where γ is a pH-independent grouping of chemical potentials, V th = kT/q denotes thermal voltage, and V t(MOS) is the threshold voltage of a conventional MOSFET. Different operational regions of the ISFETs can be used for sensing including (1) Triode (or linear region), (2) strong inversion (or saturation), (3) weak inversion (or subthreshold) and (4) velocity saturation. As aforementioned, Equation (1) describes the drain current in the triode region. Drain current of a saturated ISFET (V DS > V GS − V t(ISFET) ) is obtained by: (1 + λV ds ), (6) where λ is the channel length modulation factor. If I D and V DS both are held constant, V GS will adjust to compensate for any changes in V t(ISFET) . By assuming a zero bulk-source voltage and V DS > 4V th , the operation of an ISFET in weak inversion region can be described by [31] : where I 0 is a positive constant current and n stands for the subthreshold slope parameter. In the velocity saturation region, the operation of the device can be expressed by [32] : where v sat and V D,sat , respectively, stand for the saturated carrier velocity and the point when the drain current saturates. These principles work for semiconductor-oxide-electrolyte Chem/BioFET regardless of their geometries and channel-gates arrangement. However, the principle might not be applied to some specific Chem/BioFETs, which are working based on the sensing properties of nanomaterials like graphene or carbon nanotubes (CNTs). This fact stems from the fact that the ion complexation on these surfaces might not follow the site-bonding theory. Mathematical modeling of the molecular interaction at the surface (oxide or nitride) is extremely difficult, thus prediction of surface potential will be impossible like what sitebonding theory provides. However, in terms of modeling the interaction in BioFET surface complex systems, recently atomistic molecular dynamics simulation has been recruited to analyze the ion complexation on the surface and measure the surface potential on the channel [33] [34] [35] . State-of-the-art molecular analysis has empowered researchers to get insight into the molecular interactions at the channel surface and estimate the double-layer capacitance considering the interaction of nanomaterials, oxide, ionic solution and proteins on the surface, which is not practical possible with current models. Figure 2a -c represents the surface potential in a very complex system containing ionic solutions. In spite of the progresses in surface potential calculation modeling methods, there are still uncertainties in predicting the exact potential on the oxide surface when different "biomolecules" are available that do not affect the pH or ion concentration variations. Although the pH sensing mechanism is based on the detection of [H + ] concentration, with surface modification, we can sense other ions in the solution that introduce other mechanisms of detection that are solely based on variation of specific ion concentration (e.g., [Na + ] or [K + ]) and no longer depend on [H + ] [36] . These chemical FETs could be realized by immobilizing a sensing layer, which is only permeable to one or multiple ions in the solution. Knowing the dependence of sensor response on the concentration of specific ion in the solution (other than [H + ]), we can design a wide range of ChemFETs capable of sensing existence of a biomolecule or chemicals that do not change pH, but the concentration of other ions. Enzymatic reactions can also be another mechanism of detection by which the analyte of interest can be detected by immobilizing surface with specific enzyme that can only react with the targeted protein in the solution. The enzymatic retractions contribute to creation of acidic molecules, which directly affect the pH of solution that can be detected by BioFET sensor [37] . In recent years, oligonucleotides have been introduced and gained a growing popularity in scientific community due to their contribution in direct detection of biomolecules in BioFET. The direct detection mechanism includes functionalization of oligonucleotides on the surface of sensor, which helps to screen the macromolecules in the Debye length on the surface, since they are much smaller than proteins (target molecules) [38] . Generally, the mechanism of detection in BioFET embraces pH variation, reaction-origin detection (e.g., enzymatic or redox), direct sensing of molecule based on Debye length screening and indirect methods such as oligonucleotides functionalization of surface to detect the DNA on the surface. There is still many in-depth studies required to unravel the complex surface phenomena at the interface of electrolyte, oxide and biomolecules. BioFET sensors refer to all family of FETs dedicated to measure charge-induced field effects in different settings of bio-interfaces such as Gene-FETs (DNA-based FETs), Enzyme-FETs (Enzyme reaction detector) and Cell-FETs (FETs with biological cells as their gate). While the biological targets in these sensors are different, the mechanism of their operation is based on ISFETs operation. The invention of ISFETs goes back to 1972 when Piet Bergveld introduced the technology and tested it for pH measurements of NaCl solution. From Piet's ISFET invention in 1972 forward (about 50 years of research works), many geometries of ISFET sensors have been developed that generally can be categorized into six main groups based on their gate operation. These structures are conventional oxide-electrolyte structure (only metal of MOS is removed, and an oxide layer is deposited), unmodified CMOS technology, floating gate, extended gate, double gate structures and top gated structures, which can be modified with different nanostructures and reinforced with materials (See Figure 3 ). These structures specifically or in a combination with other forms have been recognized as the basis for further development of other biological FET sensors such as graphene-FETs (GFETs), CNT-FETs, nanowire FETs (NW-FETs) or other novel sensing materials such as MoS2 and Metal-Organic Frameworks (MOFs) [39] [40] [41] [42] [43] (See Figure 4 ). showing the floating gate structure by which the solution area has been separated from the conduction channel by an internal connection from the oxide layer on top of the channel to the solution and sensing membrane; (c) a demonstration of the integration of a floating gate with control gate, which helps to have more accurate control over the gate operation; (d) shows extended gate structure that allows us to have a bigger sensing area for biosensing purposes. Moreover, an extended gate creates enough room for further integration with the microfluidic system, which in most cases was not applicable to add them to small ISFETs; (e) oxide-electrolyte gate Chem/BioFET with the back gate in which used the back gate in order to manipulate the working point of the sensor by changing the depletion effects in the conductive channel. showing the floating gate structure by which the solution area has been separated from the conduction channel by an internal connection from the oxide layer on top of the channel to the solution and sensing membrane; (c) a demonstration of the integration of a floating gate with control gate, which helps to have more accurate control over the gate operation; (d) shows extended gate structure that allows us to have a bigger sensing area for biosensing purposes. Moreover, an extended gate creates enough room for further integration with the microfluidic system, which in most cases was not applicable to add them to small ISFETs; (e) oxide-electrolyte gate Chem/BioFET with the back gate in which used the back gate in order to manipulate the working point of the sensor by changing the depletion effects in the conductive channel. According to Figure 3a , this category of Chem/BioFET structures has been the same as the early ISFET design. From when it was invented, it has been the most applied Chem/BioFET structure in literature [44] for pH and biological analysis. The metal on the MOS sensors (as the gate) was removed and an oxide layer such as SiO2, Al2O3 or Ta2O5 was deposited on the opened gate area on top of the conductive channel, which could then a layer of nitride be deposited although it is not necessary. This sensing platform has come with different arrangements, but the only difference with the type of sensing mechanism (shown in Figure 3 ) is that the conductive channel here is the silicon itself, and no other materials are used for the enhancement of sensing capabilities. For these sensors (see Figure 3 ) SiO2 and Si3N4 have mostly been used as the oxide and nitrite layer, respectively, which play the role of dielectric. Generally, Si3N4 has been deposited on SiO2 to control the desired dielectric value in sensor. While the deposition of these oxides is completely well established, there are some concerns regarding the usage of these materials for ions sensing, since the oxide sites on the outer surface create a huge number of charge-trapping sites that will not be removed easily and will contribute to unwanted parasitic responses from the sensor [45] . The FET developed in [40] recorded a response against different concentrations of PfGDH protein spiked in buffer and serum with corresponding calibration of source-drain current versus gate voltage for different concentration of Plasmodium falciparum glutamate dehydrogenase. When concentration changed from 100 fM to 10 nM the sensor response changes (current value) changed from 0.5 µA to 0.8 µA in Vgs = 0.88 V. This structure was initially used for detection of Na + and H + ions activity for monitoring of extracellular ion pulses measured with a guinea, pig taenia coli [46] . In their design, the p-type silicon channel was brought in contact with SiO2 layer as the insulator for interaction with electrolyte. Standard oxide-electrolyte gate structure was used for evaluation of the bacterial deposition, which accumulates under conditions normally employed for telemetric monitoring of changes in human dental plaque pH [47] . As an early attempt for neuronal recording, a neuron was mounted on a thin insulating layer of a gate oxide on According to Figure 3a , this category of Chem/BioFET structures has been the same as the early ISFET design. From when it was invented, it has been the most applied Chem/BioFET structure in literature [44] for pH and biological analysis. The metal on the MOS sensors (as the gate) was removed and an oxide layer such as SiO 2 , Al 2 O 3 or Ta 2 O 5 was deposited on the opened gate area on top of the conductive channel, which could then a layer of nitride be deposited although it is not necessary. This sensing platform has come with different arrangements, but the only difference with the type of sensing mechanism (shown in Figure 3 ) is that the conductive channel here is the silicon itself, and no other materials are used for the enhancement of sensing capabilities. For these sensors (see Figure 3 ) SiO 2 and Si 3 N 4 have mostly been used as the oxide and nitrite layer, respectively, which play the role of dielectric. Generally, Si3N4 has been deposited on SiO 2 to control the desired dielectric value in sensor. While the deposition of these oxides is completely well established, there are some concerns regarding the usage of these materials for ions sensing, since the oxide sites on the outer surface create a huge number of charge-trapping sites that will not be removed easily and will contribute to unwanted parasitic responses from the sensor [45] . The FET developed in [40] recorded a response against different concentrations of Pf GDH protein spiked in buffer and serum with corresponding calibration of source-drain current versus gate voltage for different concentration of Plasmodium falciparum glutamate dehydrogenase. When concentration changed from 100 fM to 10 nM the sensor response changes (current value) changed from 0.5 µA to 0.8 µA in V gs = 0.88 V. This structure was initially used for detection of Na + and H + ions activity for monitoring of extracellular ion pulses measured with a guinea, pig taenia coli [46] . In their design, the p-type silicon channel was brought in contact with SiO 2 layer as the insulator for interaction with electrolyte. Standard oxide-electrolyte gate structure was used for evaluation of the bacterial deposition, which accumulates under conditions normally employed for telemetric monitoring of changes in human dental plaque pH [47] . As an early attempt for neuronal recording, a neuron was mounted on a thin insulating layer of a gate oxide on n-type Si in an electrolyte like the one shown in Figure 5a in which a positive bias voltage was applied to the silicon to deliver an accumulation of moveable, positive defect electrons near the surface (strong inversion). [49] , analysis of hybridization of synthetic homo-oligomer DNA sequences [50] , electrogenic cell monitoring [51] , cellular metabolism monitoring [52] , monitoring excitable neurons of rat brain [53] , cardiac muscle [54] , sensor and fluidic packaging for cellular monitoring [55] , cell proton transport mechanism analysis [56] . This structure has been recruited for cellular activity analysis with focusing on local pH measurement near the surface [57, 58] , and the adhesion analysis of cells on the substrate by measuring the pH of cells far from their culture area [59] . In the most recent couple of years, an ISFET sensor with oxide-electrolyte structure has been used for cell analysis and pH measurements. A SiO2-Ta2O5 oxide gated ISFET was used for live-cell monitoring by measuring the pH variations around cells on the gate [60, 61] . In another attempt, Si3N4/Ta2O5 oxide gated ISFET was used for studying the self-assembly of photosynthetic proteins [62] . (b) the stimuli and the sensor response at the same time, which shows the successful loading and recoding a pulse onto/from the cell using ISFET sensor. The FET-response is "current", and the stimulus is voltage. Using the well-matured CMOS technology as the main platform for the development of ISFET was a smart step toward the development of very standard ISFET sensors for biological applications [22, 63] . As an example of the transfer characteristics, the fabricated circuit delivers a linear dynamic range of 2.5 V that allows each individual ISFET to operate as a pH sensor in the array [58] . The ISFETs have a threshold voltage of −1.5 V and a sensitivity of 46 mV/pH [58] . Using unchanged CMOS structures (see Figure 3b ) for ISFET sensors comes with some advantages that make this structure very competitive in comparison to other Chem/BioFET structures. CMOS adaptation makes Chem/BioFET-based sensors very scalable and low-powered, and are being considered as two main demanding characteristics for handheld PoC devices. As shown in Figure 6 , this sensor is fabricated (a) Sensor structure for culturing cell on the oxide layer on top of the conductive channel; (b) the stimuli and the sensor response at the same time, which shows the successful loading and recoding a pulse onto/from the cell using ISFET sensor. The FET-response is "current", and the stimulus is voltage. As it is demonstrated in Figure 5b , when a positive voltage happens in the neurons during a voltage stimulation, the surface potential of silicon in the conduction channel region will be increased, which causes a reduced current in the channel (the curve shows current response). The neuron cells stimulation and recording were perfectly recorded by the oxide-electrolyte gated. This structure was used for different physicochemical settings such as immunodetection of anaerobi bacteria, which has been developed using Clostridium thermocellum cells [48] , adhesion analysis of a single neuron cell on oxidized silicon [49] , analysis of hybridization of synthetic homo-oligomer DNA sequences [50] , electrogenic cell monitoring [51] , cellular metabolism monitoring [52] , monitoring excitable neurons of rat brain [53] , cardiac muscle [54] , sensor and fluidic packaging for cellular monitoring [55] , cell proton transport mechanism analysis [56] . This structure has been recruited for cellular activity analysis with focusing on local pH measurement near the surface [57, 58] , and the adhesion analysis of cells on the substrate by measuring the pH of cells far from their culture area [59] . In the most recent couple of years, an ISFET sensor with oxide-electrolyte structure has been used for cell analysis and pH measurements. A SiO 2 -Ta 2 O 5 oxide gated ISFET was used for live-cell monitoring by measuring the pH variations around cells on the gate [60, 61] . In another attempt, Si 3 N 4 /Ta 2 O 5 oxide gated ISFET was used for studying the self-assembly of photosynthetic proteins [62] . Using the well-matured CMOS technology as the main platform for the development of ISFET was a smart step toward the development of very standard ISFET sensors for biological applications [22, 63] . As an example of the transfer characteristics, the fabricated circuit delivers a linear dynamic range of 2.5 V that allows each individual ISFET to operate as a pH sensor in the array [58] . The ISFETs have a threshold voltage of −1.5 V and a sensitivity of 46 mV/pH [58] . Using unchanged CMOS structures (see Figure 3b ) for ISFET sensors comes with some advantages that make this structure very competitive in comparison to other Chem/BioFET structures. CMOS adaptation makes Chem/BioFETbased sensors very scalable and low-powered, and are being considered as two main demanding characteristics for handheld PoC devices. As shown in Figure 6 , this sensor is fabricated by connecting the elongated gate of a transistor up to the solution that perfectly separates the solution from the sensor area. The gates, through some metal connectors buried in the oxide layer of CMOS, will be connected to the layers of Si 3 N 4 , SiO 2 , etc., which play the role of ion complexation surface for H + sensing [22] . As an example of the unchanged CMOS sensor, Milgrw et al. [63] , used a 16 × 16 array of these sensors for direct extracellular imaging. The structure of this sensor has been shown in Figure 7 . Biosensors 2021, 11, x FOR PEER REVIEW 11 of 50 by connecting the elongated gate of a transistor up to the solution that perfectly separates the solution from the sensor area. The gates, through some metal connectors buried in the oxide layer of CMOS, will be connected to the layers of Si3N4, SiO2, etc., which play the role of ion complexation surface for H + sensing [22] . As an example of the unchanged CMOS sensor, Milgrw et al. [63] , used a 16 × 16 array of these sensors for direct extracellular imaging. The structure of this sensor has been shown in Figure 7 . Along this line, new CMOS-based inventions appeared for chemical sensing. A needle-like ISFET sensor was developed for probing very small spaces in biological and chemical samples with the sensitivity of 45 mV/pH [64] . A commercial 0.25 um CMOS technology was modified as a standard ISFET for pH measurement by Georgiou and Toumazou [65] . The dimensional and shape analysis has been studied by Sohbati et al., by connecting the elongated gate of a transistor up to the solution that perfectly separates the solution from the sensor area. The gates, through some metal connectors buried in the oxide layer of CMOS, will be connected to the layers of Si3N4, SiO2, etc., which play the role of ion complexation surface for H + sensing [22] . As an example of the unchanged CMOS sensor, Milgrw et al. [63] , used a 16 × 16 array of these sensors for direct extracellular imaging. The structure of this sensor has been shown in Figure 7 . Along this line, new CMOS-based inventions appeared for chemical sensing. A needle-like ISFET sensor was developed for probing very small spaces in biological and chemical samples with the sensitivity of 45 mV/pH [64] . A commercial 0.25 um CMOS technology was modified as a standard ISFET for pH measurement by Georgiou and Toumazou [65] . The dimensional and shape analysis has been studied by Sohbati et al., Along this line, new CMOS-based inventions appeared for chemical sensing. A needlelike ISFET sensor was developed for probing very small spaces in biological and chemical samples with the sensitivity of 45 mV/pH [64] . A commercial 0.25 um CMOS technology was modified as a standard ISFET for pH measurement by Georgiou and Toumazou [65] . The dimensional and shape analysis has been studied by Sohbati et al., for taking into account all the important geometrical parameters playing a part in the operation of ISFET based standard CMOS technology [66] . A common feature in the ISFETs based on the CMOS technology is the use of SiO 2 and Si 3 N 4 , or two of them, which create additional capacitance above the silicon channel that affects the ISFET sensitivity (and also the parasitic errors). The coverage of all parts of the sensor with this thick oxide/nitride layer is a disadvantage of the sensor, which results in an unwanted capacitance that affects the threshold voltage of the sensor as the ion complexation/trapping sites on the oxide/nitrite surface will influence the electron current in silicon for next tries [65, 66] . This technology was reflected in successful real applications, working based on pH measurement such as detection of nucleic acid amplification [67] and next-generation genome sequencing [68] . Commonly, a floating electrode is used to protect the oxide sensing region on top of the channel and also provide better control over the sensitivity of the device in different operation settings, which is a preferred condition when it comes to having uniform modulation of the sensor. As shown in Figure 8 , the floating gate-based Chem/BioFET structure includes two gates, one for exposure to biological samples and another one for controlling the gate. This gate structure has been used successfully for the investigation of DNA charges on the surface of oxide as depicted in Figure 8 . for taking into account all the important geometrical parameters playing a part in the operation of ISFET based standard CMOS technology [66] . A common feature in the ISFETs based on the CMOS technology is the use of SiO2 and Si3N4, or two of them, which create additional capacitance above the silicon channel that affects the ISFET sensitivity (and also the parasitic errors). The coverage of all parts of the sensor with this thick oxide/nitride layer is a disadvantage of the sensor, which results in an unwanted capacitance that affects the threshold voltage of the sensor as the ion complexation/trapping sites on the oxide/nitrite surface will influence the electron current in silicon for next tries [65, 66] . This technology was reflected in successful real applications, working based on pH measurement such as detection of nucleic acid amplification [67] and next-generation genome sequencing [68] . Commonly, a floating electrode is used to protect the oxide sensing region on top of the channel and also provide better control over the sensitivity of the device in different operation settings, which is a preferred condition when it comes to having uniform modulation of the sensor. As shown in Figure 8 , the floating gate-based Chem/BioFET structure includes two gates, one for exposure to biological samples and another one for controlling the gate. This gate structure has been used successfully for the investigation of DNA charges on the surface of oxide as depicted in Figure 8 . The sensor illustrated in Figure 8 operates without an RE as the floating gate was used for modulation and control of the gate on oxide in which the threshold voltage varied between −0.8 to 0.8 Volts in different stages of DNA sensing procedures [69] . The floating gate structure has been used in another Chem/BioFET sensor for oxide functionalization of conductive organic electronic [70] . In [70] , the sensor has also been tested without an RE as the tests were performed in dry conditions. In an interesting job, the floating gate structure also was successfully tested for the realization of programmable ISFETs and used that for DNA analysis [71, 72] . In terms of investigation of the neuron interactions, floating gate structure was used as a sensing platform by Cohen et al. [73] . They designed a floating gate structure that provides a wide gate area for monitoring the chemical reactions, which makes it a good sensor for integration with microfluidic [73] . Chemoreceptive neuron MOS (CνMOS) transistors have been used for electrochemical recordings of exocytosis from populations of the mast and chromaffin cells [74] . This sensor arrangement by means of a floating gate structure (coexistence of control gate, sensing gate and floating gates together), allows the simultaneous control of the electrolyte and ions quiescent point to be independently controlled. The sensor is also CMOS-compatible and physically isolates the transistor channel from the electrolyte for stable long-term recordings [74] . The sensor illustrated in Figure 8 operates without an RE as the floating gate was used for modulation and control of the gate on oxide in which the threshold voltage varied between −0.8 to 0.8 Volts in different stages of DNA sensing procedures [69] . The floating gate structure has been used in another Chem/BioFET sensor for oxide functionalization of conductive organic electronic [70] . In [70] , the sensor has also been tested without an RE as the tests were performed in dry conditions. In an interesting job, the floating gate structure also was successfully tested for the realization of programmable ISFETs and used that for DNA analysis [71, 72] . In terms of investigation of the neuron interactions, floating gate structure was used as a sensing platform by Cohen et al. [73] . They designed a floating gate structure that provides a wide gate area for monitoring the chemical reactions, which makes it a good sensor for integration with microfluidic [73] . Chemoreceptive neuron MOS (CνMOS) transistors have been used for electrochemical recordings of exocytosis from populations of the mast and chromaffin cells [74] . This sensor arrangement by means of a floating gate structure (coexistence of control gate, sensing gate and floating gates together), allows the simultaneous control of the electrolyte and ions quiescent point to be independently controlled. The sensor is also CMOS-compatible and physically isolates the transistor channel from the electrolyte for stable long-term recordings [74] . The integration of FET sensors with a microfluidic platform for directing the solution and biomaterials toward the sensor is a big challenge in biosensor integration. However, a good approach for alleviating this issue is to extend the gate of the FET sensor compact area to meet the biological matters [75, 76] . This structure helps to have a much simpler fabrication process, as the sensing area can be fabricated according to the design demand of the fluidic section. Regular FET biosensor designs as discussed in previous sections (oxide-electrode gate and floating gates) come with some challenges mostly associated with the inevitable surface chemistry of ion complexations and the following ion trapping phenomena, which leads to the development of noise in the output signal [75] . Extended gate Chem/BioFETs have been designed to improve these deficiencies, which are investigated in literature with different applications for pH measurement of ion solutions and other bio-interfaces [16] . In comparison with ISFETs, extended gate FETs have shown much better stability in terms of chemical, thermal and incident light disturbances in parallel with greater sensitivity [16, 77] . Figure 9 demonstrates an example of an extended gate FET sensor that has been used as a platform for biochemical analysis [76] Biosensors 2021, 11, x FOR PEER REVIEW 13 of 50 The integration of FET sensors with a microfluidic platform for directing the solution and biomaterials toward the sensor is a big challenge in biosensor integration. However, a good approach for alleviating this issue is to extend the gate of the FET sensor compact area to meet the biological matters [75, 76] . This structure helps to have a much simpler fabrication process, as the sensing area can be fabricated according to the design demand of the fluidic section. Regular FET biosensor designs as discussed in previous sections (oxide-electrode gate and floating gates) come with some challenges mostly associated with the inevitable surface chemistry of ion complexations and the following ion trapping phenomena, which leads to the development of noise in the output signal [75] . Extended gate Chem/BioFETs have been designed to improve these deficiencies, which are investigated in literature with different applications for pH measurement of ion solutions and other bio-interfaces [16] . In comparison with ISFETs, extended gate FETs have shown much better stability in terms of chemical, thermal and incident light disturbances in parallel with greater sensitivity [16, 77] . Figure 9 demonstrates an example of an extended gate FET sensor that has been used as a platform for biochemical analysis [76] Due to the specific characteristics of extended gate FET for biosensing applications, many are designed for various detection applications such as pH, urea, glucose, calcium ion, DNA, and immunosensors, which have been registered. A complete review of these sensors is done in other work by Pullano et al. [75] . An extended gate sensor was used for direct potentiometric serological diagnosis toward detection of Bovine Herpes Virus-1 (BHV-1) pathogen by Tarasov et al. [77] . Their design has been shown in Figure 10 , which demonstrates an extended gate connected to the gate of a MOSFET. In their experiment, concentrations of p53wt changed from 50 pM to 10 nM, whcih resulted in Ids jumps ranging from about −5.0 × 10 −8 A up to about −5.0 × 10 −7 A. Due to the specific characteristics of extended gate FET for biosensing applications, many are designed for various detection applications such as pH, urea, glucose, calcium ion, DNA, and immunosensors, which have been registered. A complete review of these sensors is done in other work by Pullano et al. [75] . An extended gate sensor was used for direct potentiometric serological diagnosis toward detection of Bovine Herpes Virus-1 (BHV-1) pathogen by Tarasov et al. [77] . Their design has been shown in Figure 10 , which demonstrates an extended gate connected to the gate of a MOSFET. In their experiment, concentrations of p53wt changed from 50 pM to 10 nM, whcih resulted in Ids jumps ranging from about −5.0 × 10 −8 A up to about −5.0 × 10 −7 A. Double gate sensors have the same structures, which are presented before in term of the drain/source and channel operation mechanism. These sensors mostly operate un der an RE while another gate at the back of the sensor helps to manipulate the sensors operation point. Due to this further operation control using back gate, they were intende to go beyond the Nernstian limit, which defines the ISFETs sensitivity limit [78] [79] [80] . Spijk man et al., in a very interesting piece of research work, introduced a new configuration o ISFETs using double gate concept in which they could push the Nernstian limit to abou 2.25 V/pH using a self-assembly polymer as the solution interface gate on top of ZnO channel with a back gate that contributes to the creation of bottom capacitance [79,80 ( Figure 11 shows the double gate sensor). The double gate structure was also reported by Huang et al., as an efficient way t improve the performance of standard CMOS-based ISFETs. They reported a dual-gat ISFET sensor structure, as depicted in Figure 12 , which is developed in a standard 0.1 µm SOI-CMOS process followed by an additional backside process [81] . Using poly gat (PG) (see Figure 12 ) as the second gate of double-gated CMOS standard ISFET structure helped them to significantly improve the characteristics of ISFETs such as 155 times im provement in signal-to-noise ratio (SNR), 53 times improvement in drift rates, 3.7 time hysteresis reduction, and last but not least, 7.5 times sensitivity increment [82] . Back gat structure has been used frequently in FET structures in which nanomaterials (please se Figure 3b ) were deposited on the oxide and played the role of main conductive channe The most noteworthy ones are CNT-based FETs [83] , grapheme-FETs [82] , silicon nan Double gate sensors have the same structures, which are presented before in terms of the drain/source and channel operation mechanism. These sensors mostly operate under an RE while another gate at the back of the sensor helps to manipulate the sensors' operation point. Due to this further operation control using back gate, they were intended to go beyond the Nernstian limit, which defines the ISFETs sensitivity limit [78] [79] [80] . Spijkman et al., in a very interesting piece of research work, introduced a new configuration of ISFETs using double gate concept in which they could push the Nernstian limit to about 2.25 V/pH using a self-assembly polymer as the solution interface gate on top of ZnO channel with a back gate that contributes to the creation of bottom capacitance [79, 80] ( Figure 11 shows the double gate sensor). Double gate sensors have the same structures, which are presented before in term of the drain/source and channel operation mechanism. These sensors mostly operate un der an RE while another gate at the back of the sensor helps to manipulate the sensors operation point. Due to this further operation control using back gate, they were intende to go beyond the Nernstian limit, which defines the ISFETs sensitivity limit [78] [79] [80] . Spijk man et al., in a very interesting piece of research work, introduced a new configuration o ISFETs using double gate concept in which they could push the Nernstian limit to abou 2.25 V/pH using a self-assembly polymer as the solution interface gate on top of ZnO channel with a back gate that contributes to the creation of bottom capacitance [79,80 ( Figure 11 shows the double gate sensor). The double gate structure was also reported by Huang et al., as an efficient way t improve the performance of standard CMOS-based ISFETs. They reported a dual-gat ISFET sensor structure, as depicted in Figure 12 , which is developed in a standard 0.1 µm SOI-CMOS process followed by an additional backside process [81] . Using poly gat (PG) (see Figure 12 ) as the second gate of double-gated CMOS standard ISFET structure helped them to significantly improve the characteristics of ISFETs such as 155 times im provement in signal-to-noise ratio (SNR), 53 times improvement in drift rates, 3.7 time hysteresis reduction, and last but not least, 7.5 times sensitivity increment [82] . Back gat structure has been used frequently in FET structures in which nanomaterials (please se Figure 3b ) were deposited on the oxide and played the role of main conductive channe The most noteworthy ones are CNT-based FETs [83] , grapheme-FETs [82] , silicon nan owire (SiNW)-FETs [ The double gate structure was also reported by Huang et al., as an efficient way to improve the performance of standard CMOS-based ISFETs. They reported a dual-gate ISFET sensor structure, as depicted in Figure 12 , which is developed in a standard 0.18 µm SOI-CMOS process followed by an additional backside process [81] . Using poly gate (PG) (see Figure 12 ) as the second gate of double-gated CMOS standard ISFET structure, helped them to significantly improve the characteristics of ISFETs such as 155 times improvement in signal-to-noise ratio (SNR), 53 times improvement in drift rates, 3.7 times hysteresis reduction, and last but not least, 7.5 times sensitivity increment [82] . Back gate structure has been used frequently in FET structures in which nanomaterials (please see Figure 3b ) were deposited on the oxide and played the role of main conductive channel. The most notewor-thy ones are CNT-based FETs [83] , grapheme-FETs [82] , silicon nanowire (SiNW)-FETs [84] , MoS2 FETs [85] , MOF FETs [42] , ZnO FETs [42, 86] and other nanomaterials utilized the double gate and in the form of a solution gate and a back gate for sensing procedures. Dual-gate ISFET sensor structure developed in a standard 0.18 µm SOI-CMOS process and through a backside process the back gate has been developed to make a double-gate structure The sensor completely is working based on the CMOS readout. As previous discussions have shown, various structures of ISFETs have been em ployed in Chem/BioFET biosensing systems. These sensors have also been frequently use for the detection of infectious diseases. Almost all of the Chem/BioFETs used for infectiou diseases have been based on the electrolyte gate on the main channel. However, ther were some examples of other structures as well. For detection of a sequence of Hepatitis C Virus (HCV) at very low concentration down to the pM range, a Peptide Nucleic Acid (PNA) CNT-based FET structure senso was used in which the sensor was working based on the Ag/AgCl solution gate in th electrolyte [87] . The structure of the fabricated sensor is shown in Figure 13 , which con sisted of metallic SWNTs that would lower the sensitivity of the devices for sensing ap plications. In this work, to lessen the effect of contact residence between single wall CNT (SWCNTs) and the metal layer, the contact areas were passivated with microlithograp cally patterned Al2O3 (50 nm) or self-assembled dodecanethiol (DDT) monolayers [87] . Lee et al. [88] developed an extended gate Chem/BioFET structure (see Figure 14 that has been manufactured based on the 0.35 µm CMOS process, which was integrate with working electrodes, an RE and readout circuits into one package. A detectable rang of 88.3 dB and an LoD of 36 µV were reported for this sensor, which led to a successfu Chem/BioFET for the detection of oligonucleotide sequences derived from the H5N Figure 12 . Dual-gate ISFET sensor structure developed in a standard 0.18 µm SOI-CMOS process and through a backside process the back gate has been developed to make a double-gate structure. The sensor completely is working based on the CMOS readout. As previous discussions have shown, various structures of ISFETs have been employed in Chem/BioFET biosensing systems. These sensors have also been frequently used for the detection of infectious diseases. Almost all of the Chem/BioFETs used for infectious diseases have been based on the electrolyte gate on the main channel. However, there were some examples of other structures as well. For detection of a sequence of Hepatitis C Virus (HCV) at very low concentrations down to the pM range, a Peptide Nucleic Acid (PNA) CNT-based FET structure sensor was used in which the sensor was working based on the Ag/AgCl solution gate in the electrolyte [87] . The structure of the fabricated sensor is shown in Figure 13 , which consisted of metallic SWNTs that would lower the sensitivity of the devices for sensing applications. In this work, to lessen the effect of contact residence between single wall CNTs (SWCNTs) and the metal layer, the contact areas were passivated with microlithograpically patterned Al 2 O 3 (50 nm) or self-assembled dodecanethiol (DDT) monolayers [87] . Dual-gate ISFET sensor structure developed in a standard 0.18 µm SOI-CMOS process and through a backside process the back gate has been developed to make a double-gate structure. The sensor completely is working based on the CMOS readout. As previous discussions have shown, various structures of ISFETs have been employed in Chem/BioFET biosensing systems. These sensors have also been frequently used for the detection of infectious diseases. Almost all of the Chem/BioFETs used for infectious diseases have been based on the electrolyte gate on the main channel. However, there were some examples of other structures as well. For detection of a sequence of Hepatitis C Virus (HCV) at very low concentrations down to the pM range, a Peptide Nucleic Acid (PNA) CNT-based FET structure sensor was used in which the sensor was working based on the Ag/AgCl solution gate in the electrolyte [87] . The structure of the fabricated sensor is shown in Figure 13 , which consisted of metallic SWNTs that would lower the sensitivity of the devices for sensing applications. In this work, to lessen the effect of contact residence between single wall CNTs (SWCNTs) and the metal layer, the contact areas were passivated with microlithograpically patterned Al2O3 (50 nm) or self-assembled dodecanethiol (DDT) monolayers [87] . Lee et al. [88] developed an extended gate Chem/BioFET structure (see Figure 14 ) that has been manufactured based on the 0.35 µm CMOS process, which was integrated with working electrodes, an RE and readout circuits into one package. A detectable range of 88.3 dB and an LoD of 36 µV were reported for this sensor, which led to a successful Chem/BioFET for the detection of oligonucleotide sequences derived from the H5N1 avian influenza virus (AIV). The structure of this sensor is introduced in Figure 14a ,b, Figure 13 . FET structure used for detection of RNA. In the figure, Au 1 and Au 2 demonstrate the source and drain pads, respectively. The gate potential has been applied through the Ag/AgCl as RE, and in this picture, the V b is the bias voltage of the source-drain. Lee et al. [88] developed an extended gate Chem/BioFET structure (see Figure 14 ) that has been manufactured based on the 0.35 µm CMOS process, which was integrated with working electrodes, an RE and readout circuits into one package. A detectable range of 88.3 dB and an LoD of 36 µV were reported for this sensor, which led to a successful Chem/BioFET for the detection of oligonucleotide sequences derived from the H5N1 avian influenza virus (AIV). The structure of this sensor is introduced in Figure 14a ,b, which shows a conceptual view of the integration and working principle of the device. All of the electrodes were built in the device area, which included working electrodes, an Au (numbers (1) and (3)) modified along with DNA strands and an RE (Al, number (2)) that determines the potential of the analyte solution. After the introduction of the sample on the functionalized extended gate, the signal will be processed in the CMOS circuitry. (numbers (1) and (3)) modified along with DNA strands and an RE (Al, number (2)) that determines the potential of the analyte solution. After the introduction of the sample on the functionalized extended gate, the signal will be processed in the CMOS circuitry. Another CMOS-based Chem/BioFET platform is shown in Figure 15 that utilizes a gated area on the main channel while the solution is introduced onto the sensor through an underlap region [89] . In the sensor shown in Figure 15 , to examine the effect of hydrophilicity and hydrophobicity on the response of the sensor, a thin film of CYTOP TM and silicon nitride has been used as the hydrophobic and hydrophilic passivation layers, respectively. The sensor finally was tested toward detection of surface antigen and its specific antibody of the AIV. This work introduced a method for enhancement of the sensitivity of CMOS-based Chem/BioFET sensors for better detection of infectious disease and in particular influenza [89] . As it was shown in Figure 2 , many sensors have employed nanomaterials as the sensing element, which are considered as conductive channels. Almost all sorts of these sensors are working based on the back-gate structure. Therefore, double-gated Chem/Bio-FETs considering one of the gates as a RE in the electrolyte solution. One of these structures employing both the back gate and also a solution gate was implemented on the SiNW-based sensor for detection of H5N2 AIV in a very dilute solution [90] . To facilitate the integration of the RE with the SiNW, it was positioned inside the solution where the fluid was directed inside, as shown in Figure 16 . Another CMOS-based Chem/BioFET platform is shown in Figure 15 that utilizes a gated area on the main channel while the solution is introduced onto the sensor through an underlap region [89] . In the sensor shown in Figure 15 , to examine the effect of hydrophilicity and hydrophobicity on the response of the sensor, a thin film of CYTOP TM and silicon nitride has been used as the hydrophobic and hydrophilic passivation layers, respectively. The sensor finally was tested toward detection of surface antigen and its specific antibody of the AIV. This work introduced a method for enhancement of the sensitivity of CMOSbased Chem/BioFET sensors for better detection of infectious disease and in particular influenza [89] . which shows a conceptual view of the integration and working principle of the device. All of the electrodes were built in the device area, which included working electrodes, an Au (numbers (1) and (3)) modified along with DNA strands and an RE (Al, number (2)) that determines the potential of the analyte solution. After the introduction of the sample on the functionalized extended gate, the signal will be processed in the CMOS circuitry. Another CMOS-based Chem/BioFET platform is shown in Figure 15 that utilizes a gated area on the main channel while the solution is introduced onto the sensor through an underlap region [89] . In the sensor shown in Figure 15 , to examine the effect of hydrophilicity and hydrophobicity on the response of the sensor, a thin film of CYTOP TM and silicon nitride has been used as the hydrophobic and hydrophilic passivation layers, respectively. The sensor finally was tested toward detection of surface antigen and its specific antibody of the AIV. This work introduced a method for enhancement of the sensitivity of CMOS-based Chem/BioFET sensors for better detection of infectious disease and in particular influenza [89] . As it was shown in Figure 2 , many sensors have employed nanomaterials as the sensing element, which are considered as conductive channels. Almost all sorts of these sensors are working based on the back-gate structure. Therefore, double-gated Chem/Bio-FETs considering one of the gates as a RE in the electrolyte solution. One of these structures employing both the back gate and also a solution gate was implemented on the SiNW-based sensor for detection of H5N2 AIV in a very dilute solution [90] . To facilitate the integration of the RE with the SiNW, it was positioned inside the solution where the fluid was directed inside, as shown in Figure 16 . As it was shown in Figure 2 , many sensors have employed nanomaterials as the sensing element, which are considered as conductive channels. Almost all sorts of these sensors are working based on the back-gate structure. Therefore, double-gated Chem/BioFETs considering one of the gates as a RE in the electrolyte solution. One of these structures employing both the back gate and also a solution gate was implemented on the SiNW-based sensor for detection of H5N2 AIV in a very dilute solution [90] . To facilitate the integration of the RE with the SiNW, it was positioned inside the solution where the fluid was directed inside, as shown in Figure 16 . The ultrasensitive detection of H5N2 AIV was demonstrated using a reusable SiNW FET, which was made possible by the reversible surface functionalization on the SiNW via a disulphide linker. They reported a successful reversible surface functionalization, which was then examined by electrical and microfluorescence methods. By this innovation, they could reach detections of very dilute H5N2 AIV at 10 −12 -10 −17 M [90] . As a back gated structure for SiNW sensors, based on a CMOS fabrication process, a label-free and specific DNA detector were devised in which by applying rolling circle amplification (RCA) on SiNW-FET, they could get higher sensitivity and better performance. Back gated structure was also used for direct detection of airborne viruses without using any solution and wet fluidic section [91] . According to this method, the virus-antibody connected particles are delivered to the FET during detection in which the regular pretreatment and the antibody binding step on the FET channel are not required. In this method, they have eliminated the washing process for the virus-antibody binding [91] . On top of the sensor area, a layer of CNT was coated, which was used for the detection of virus deposition from the electro-aerodynamics separator (see Figure 17 ). The ultrasensitive detection of H5N2 AIV was demonstrated using a reusable SiNW FET, which was made possible by the reversible surface functionalization on the SiNW via a disulphide linker. They reported a successful reversible surface functionalization, which was then examined by electrical and microfluorescence methods. By this innovation, they could reach detections of very dilute H5N2 AIV at 10 −12 -10 −17 M [90] . As a back gated structure for SiNW sensors, based on a CMOS fabrication process, a label-free and specific DNA detector were devised in which by applying rolling circle amplification (RCA) on SiNW-FET, they could get higher sensitivity and better performance. Back gated structure was also used for direct detection of airborne viruses without using any solution and wet fluidic section [91] . According to this method, the virus-antibody connected particles are delivered to the FET during detection in which the regular pretreatment and the antibody binding step on the FET channel are not required. In this method, they have eliminated the washing process for the virus-antibody binding [91] . On top of the sensor area, a layer of CNT was coated, which was used for the detection of virus deposition from the electro-aerodynamics separator (see Figure 17 ). In another study, the integration of a double gate and extended gate was studied to introduce a new sensor structure (see Figure 18 ). A so-called 'disposable well gate' was connected to the top gate of a channel, which was used to detect AIV [92] . This research reports a FET-based AIV sensor that was capable of detecting nucleoproteins within 30 min, down to an LoD of 10 3 EID 50 mL −1 from a live animal swab sample [92] . The back gate structure in another Chem/BioFET was used for Ebola virus disease (EVD) detection [93] . Reduced graphene oxide (rGO)-FET, which was controlled by a back gate was used for real-time detection of the Ebola virus antigen [93] . The same gating structure was used for developing an indium tin oxide (ITO) NW-based FET for DNA biosensing, which was used in particular for the detection of hepatitis B virus (HBV) based on ITONWs [94] . As a back gated structure for SiNW sensors, based on a CMOS fabrication process, a label-free and specific DNA detector were devised in which by applying rolling circle amplification (RCA) on SiNW-FET, they could get higher sensitivity and better performance. Back gated structure was also used for direct detection of airborne viruses without using any solution and wet fluidic section [91] . According to this method, the virus-antibody connected particles are delivered to the FET during detection in which the regular pretreatment and the antibody binding step on the FET channel are not required. In this method, they have eliminated the washing process for the virus-antibody binding [91] . On top of the sensor area, a layer of CNT was coated, which was used for the detection of virus deposition from the electro-aerodynamics separator (see Figure 17 ). In another study, the integration of a double gate and extended gate was studied to introduce a new sensor structure (see Figure 18) . A so-called 'disposable well gate' was connected to the top gate of a channel, which was used to detect AIV [92] . This research reports a FET-based AIV sensor that was capable of detecting nucleoproteins within 30 min, down to an LoD of 10 3 EID50 mL −1 from a live animal swab sample [92] . The back gate structure in another Chem/BioFET was used for Ebola virus disease (EVD) detection [93] . Reduced graphene oxide (rGO)-FET, which was controlled by a back gate was used for real-time detection of the Ebola virus antigen [93] . The same gating structure was used for developing an indium tin oxide (ITO) NW-based FET for DNA biosensing, which was used in particular for the detection of hepatitis B virus (HBV) based on ITONWs [94] . Based on our review, it seems there were a limited number of papers, which have used standard FET sensor fabricated based on CMOS technology for infectious disease detection. However, many of them have been fabricated based on laboratory microfabrication techniques. As far as the gating structure is concerned, many of Chem/BioFET infectious detector structures have been based on the top-gated type that generally is a solution gate with an RE. In the next chapter, we have reviewed the biological interface of the aforementioned Chem/BioFETs dedicated especially to infectious disease screening. The operation of FET biosensors depends on the bioreactions that occur on their surface [95] . Their efficiency and preciseness are contingent on the selectivity and availability of the bio-recognition elements (BREs). Therefore, proper surface functionalization is imperative for optimizing the BRE immobilization, enhancing the sensitivity, preventing unwanted reactions and minimizing the noise [96] . Additionally, the type of material used to cover the sensor's surface to increase its biocompatibility and surface chemistry play a crucial role in improving the performance of the sensor [97] . As mentioned in the previous section, a wide range of substrates is utilized for this purpose including gold, nanowire (NWs), CNT, graphene, glycan, etc. [98] . The use of nanomaterials with extraordinary characteristics such as small size, high chemical and mechanical stability, considerable electrical conductivity, nontoxicity and high surface-to-volume ratio offers an optimum sensing area for operating an accurate detection [99] . Especially, one-dimensional nanostructures improve the sensor's performance significantly and increase the LoD down to attomolar levels [100] . These structures enable label-free electrical detection of biospecies in a sensitive and precise manner [101] . Table 1 compares some of FET biosensors reported recently for detecting various infectious agents, especially different viruses. Herein, after introducing different materials useful for covering the sensors' surface in Section 3.1, different type of BREs will be reviewed in Section 3.2. Based on our review, it seems there were a limited number of papers, which have used standard FET sensor fabricated based on CMOS technology for infectious disease detection. However, many of them have been fabricated based on laboratory microfabrication techniques. As far as the gating structure is concerned, many of Chem/BioFET infectious detector structures have been based on the top-gated type that generally is a solution gate with an RE. In the next chapter, we have reviewed the biological interface of the aforementioned Chem/BioFETs dedicated especially to infectious disease screening. The operation of FET biosensors depends on the bioreactions that occur on their surface [95] . Their efficiency and preciseness are contingent on the selectivity and availability of the bio-recognition elements (BREs). Therefore, proper surface functionalization is imperative for optimizing the BRE immobilization, enhancing the sensitivity, preventing unwanted reactions and minimizing the noise [96] . Additionally, the type of material used to cover the sensor's surface to increase its biocompatibility and surface chemistry play a crucial role in improving the performance of the sensor [97] . As mentioned in the previous section, a wide range of substrates is utilized for this purpose including gold, nanowire (NWs), CNT, graphene, glycan, etc. [98] . The use of nanomaterials with extraordinary characteristics such as small size, high chemical and mechanical stability, considerable electrical conductivity, nontoxicity and high surface-to-volume ratio offers an optimum sensing area for operating an accurate detection [99] . Especially, one-dimensional nanostructures improve the sensor's performance significantly and increase the LoD down to attomolar levels [100] . These structures enable label-free electrical detection of biospecies in a sensitive and precise manner [101] . Table 1 compares some of FET biosensors reported recently for detecting various infectious agents, especially different viruses. Herein, after introducing different materials useful for covering the sensors' surface in Section 3.1, different type of BREs will be reviewed in Section 3.2. NW-FETs are one of the most used categories of Chem/BioFETs [117] . In these systems, the channel and gate of a standard Chem/BioFET are functionalized with NWs and BREs [118] . Despite their different configuration, they operate through the same procedure. NWs can be fabricated through bottom-up (chemical etching, vapour-liquid-solid, and oxide-assisted growth) or top-down approaches from semiconductor materials [119] . SiNWs are among the commonly preferred alternatives because of their facile fabrication and modification process [120] . Their surface should be functionalized with specific BREs to be sensitive to the target viruses. This can be done through physical adsorption and chemical cross-linking [121] . After exposing the functionalized surface to the sample, an electric field is induced onto the NWs and changes their conductivity as a result of the interaction between the charged target and receptors [122] . Several types of biological interactions such as antibody-antigen, protein-ligand, and oligonucleotide hybridization can be inspected on the surface of NW-FET biosensors [123] . Recently, several studies have focused on developing novel biosensing platforms for detecting viruses. For example, a very recent study was conducted for detecting the influenza virus (IV) using a SiNW-FETbased biosensor, which was fabricated through CMOS technology. This system was able to spot down to 1 fM of the target protein [102] . As illustrated in Figure 19 , another FET genosensor was designed to detect HBV based on ITONWs, which facilitated the surface functionalization and hybridization process significantly. After coating the nanowires with gold, they were modified with single-stranded DNA (ssDNA). This arrangement was successful enough to identify 1 fM of the viral genome in 37 s and discriminate the target from other oligonucleotides [94] . 3.1.1. Nanowires NW-FETs are one of the most used categories of Chem/BioFETs [117] . In these tems, the channel and gate of a standard Chem/BioFET are functionalized with NWs BREs [118] . Despite their different configuration, they operate through the same p dure. NWs can be fabricated through bottom-up (chemical etching, vapour-liquid-s and oxide-assisted growth) or top-down approaches from semiconductor materials [ SiNWs are among the commonly preferred alternatives because of their facile fabrica and modification process [120] . Their surface should be functionalized with specific B to be sensitive to the target viruses. This can be done through physical adsorption chemical cross-linking [121] . After exposing the functionalized surface to the sampl electric field is induced onto the NWs and changes their conductivity as a result o interaction between the charged target and receptors [122] . Several types of biologica teractions such as antibody-antigen, protein-ligand, and oligonucleotide hybridiza can be inspected on the surface of NW-FET biosensors [123] . Recently, several stu have focused on developing novel biosensing platforms for detecting viruses. For e ple, a very recent study was conducted for detecting the influenza virus (IV) usi SiNW-FET-based biosensor, which was fabricated through CMOS technology. This tem was able to spot down to 1 fM of the target protein [102] . As illustrated in Figur another FET genosensor was designed to detect HBV based on ITONWs, which facili the surface functionalization and hybridization process significantly. After coating nanowires with gold, they were modified with single-stranded DNA (ssDNA). Thi rangement was successful enough to identify 1 fM of the viral genome in 37 s and criminate the target from other oligonucleotides [94] . Au-modified surfaces represent a popular approach for surface functionalizatio FET-based sensing systems since they provide a stable platform for immobilizing BREs, boosting the electron shuttle rate, and upgrading the performance of the de [95, 124] . Furthermore, the high biocompatibility of these surfaces preserves the func ality of the BREs and optimizes their efficiency in interacting with target biomolec [125] . More importantly, the wide available area that is provided by gold nanopart enables the immobilization of a large number of receptors and accordingly augment sensitivity of detection [126] . In recent years, several studies employed this strateg designing biosensors for detecting viral particles. For instance, a reusable FET-based vice was fabricated to identify AIV, using aptamer-modified gold microelectrodes Figure 20 ). The hemagglutinin (HA)-specific aptamers' interaction with the target bio ecules alters the surface potential, which is recorded as a signal. The LoD was report 5.9 pM, which shows the preciseness of the detection in chicken serum. The easy cheap fabrication process of this portable platform makes it an ideal approach for Au-modified surfaces represent a popular approach for surface functionalization of FET-based sensing systems since they provide a stable platform for immobilizing the BREs, boosting the electron shuttle rate, and upgrading the performance of the device [95, 124] . Furthermore, the high biocompatibility of these surfaces preserves the functionality of the BREs and optimizes their efficiency in interacting with target biomolecules [125] . More importantly, the wide available area that is provided by gold nanoparticles enables the immobilization of a large number of receptors and accordingly augments the sensitivity of detection [126] . In recent years, several studies employed this strategy for designing biosensors for detecting viral particles. For instance, a reusable FET-based device was fabricated to identify AIV, using aptamer-modified gold microelectrodes (see Figure 20) . The hemagglutinin (HA)-specific aptamers' interaction with the target biomolecules alters the surface potential, which is recorded as a signal. The LoD was reported at 5.9 pM, which shows the preciseness of the detection in chicken serum. The easy and cheap fabrication process of this portable platform makes it an ideal approach for PoC diagnosis of viral particles in biological samples [104] . In another study, an immune-FET was designed for detecting the capsid protein of HIV. The gate of the device was covered by a monolayer of gold to provide a biocompatible area for immobilizing target-specific antibodies. The ultra-sensitive recognition power of this strategy (LoD = 30 × 10 −21 M) enables reliable, economical and portable detection of single molecules [105] (see Table 1 ). Biosensors 2021, 11, x FOR PEER REVIEW 22 diagnosis of viral particles in biological samples [104] . In another study, an immune was designed for detecting the capsid protein of HIV. The gate of the device was cov by a monolayer of gold to provide a biocompatible area for immobilizing target-spe antibodies. The ultra-sensitive recognition power of this strategy (LoD = 30 × 10 −21 M ables reliable, economical and portable detection of single molecules [105] (see Table Figure 20. The illustration of the FET-based aptasensor for detecting AIV in chicken serum. Th surface of the gold electrode was modified with specific DNA aptamers for identifying the su protein of the virus. The interaction between the probe and the target resulted in the structura change of the aptamers which was recorded as the surface potential. Graphene is the other widespread material for surface coating in biosensor des [127] . It has several other forms such as graphene oxide (GO), rGO and graphene n ribbon (GNR), which have been extensively used in the structure of sensing device cause of their chemical, mechanical, and electronic attributions [128, 129] . This biologi friendly carbon-based material provides a wide area with numerous anchor spot functionalizing the surface with diverse nanoparticles, polymers or any other signal plifier before immobilizing the BREs. Additionally, it has exceptional electrical condu ity, high capacitance, low contact resistance and tunable ambipolar field-effect behav Since it increases the electron transfer rate, the response time of the biosensor decre significantly [130, 131] . Besides, its cost-effectiveness, easy fabrication and biocompa ity turn it into one of the most preferred materials for coating the surface of virus-spe FET-based bioassays. As an instance, Jin et al. proposed a FET-based immunosensing vice for the detection of the Ebola virus. As depicted in Figure 21 , the surface of the se was functionalized by rGO before immobilizing antibodies. The LOD was reporte pg·mL −1 of the target glycoprotein in spiked serum samples [93] . Graphene is the other widespread material for surface coating in biosensor designs [127] . It has several other forms such as graphene oxide (GO), rGO and graphene nanoribbon (GNR), which have been extensively used in the structure of sensing devices because of their chemical, mechanical, and electronic attributions [128, 129] . This biologically friendly carbon-based material provides a wide area with numerous anchor spots for functionalizing the surface with diverse nanoparticles, polymers or any other signal amplifier before immobilizing the BREs. Additionally, it has exceptional electrical conductivity, high capacitance, low contact resistance and tunable ambipolar field-effect behaviors. Since it increases the electron transfer rate, the response time of the biosensor decreases significantly [130, 131] . Besides, its cost-effectiveness, easy fabrication and biocompatibility turn it into one of the most preferred materials for coating the surface of virus-specific FET-based bioassays. As an instance, Jin et al. proposed a FET-based immunosensing device for the detection of the Ebola virus. As depicted in Figure 21 , the surface of the sensor was functionalized by rGO before immobilizing antibodies. The LOD was reported 2.4 pg·mL −1 of the target glycoprotein in spiked serum samples [93] . In another study, a GFET system was reported for detecting IV and studying the an tiviral medications' effect on it. Sialic acid was used as a probe for recognizing the HA o the surface of the virus. Besides, the repressive effect of "zanamivir" on this interactio was investigated. This work represented the compatibility of these platforms for quant fying biological reactions in biosensing and drug development applications [113] . Aspe mair and colleagues constructed a FET aptasensor for the identification of human papi lomavirus (HPV). The surface of the sensor was characterized by rGO, pyrene and RN aptamers to spot viral proteins in saliva samples. They successfully detected as low as 1.7 nM of the target molecules, which indicated the competency of the device in real-tim detection of viral infections [109] . CNTs have been the focus of attention from researchers' viewpoint due to their su perior conductivity and exceptional configuration [132, 133] . These hollow carbon-base arrangements might have one (SWCNT) or more walls (multi-walled CNT) consisting hexagonal frames of carbon [134] . In other words, they are rolled graphene sheets th have been capped at both ends. Owing to their systematic and well-organized structur they display high mechanical stamina, which makes them an ideal choice for biosensin applications [135, 136] . In addition, CNTs deliver a broad surface area for immobilizing great number of BREs [137] . Thus, they are being commonly employed in detecting viru related biomarkers in biological samples. For instance, a FET-based assay was develope for recognizing tiny amounts of HCV employing SWCNT. PNA was used as the prob and detected 0.5 pM of the target particles [87] . In a different research work, a simple-t use FET biosensor was projected for the quantification of aerosolized viruses (see Figu 22) . The core strategy of this approach was the higher number of charge carriers and larg sizes of the antibody-antigen complexes compared to unbound antibodies or viruses. Th fact led to the deposition of these big particles on a specific region of the substrate. In th case that this area overlaps with the SWCNT-modified channel of the transistor, a chang will occur in the recorded current that signifies the existence of the virus [91] . In another study, a GFET system was reported for detecting IV and studying the antiviral medications' effect on it. Sialic acid was used as a probe for recognizing the HA on the surface of the virus. Besides, the repressive effect of "zanamivir" on this interaction was investigated. This work represented the compatibility of these platforms for quantifying biological reactions in biosensing and drug development applications [113] . Aspermair and colleagues constructed a FET aptasensor for the identification of human papillomavirus (HPV). The surface of the sensor was characterized by rGO, pyrene and RNA aptamers to spot viral proteins in saliva samples. They successfully detected as low as 1.75 nM of the target molecules, which indicated the competency of the device in real-time detection of viral infections [109] . CNTs have been the focus of attention from researchers' viewpoint due to their superior conductivity and exceptional configuration [132, 133] . These hollow carbon-based arrangements might have one (SWCNT) or more walls (multi-walled CNT) consisting of hexagonal frames of carbon [134] . In other words, they are rolled graphene sheets that have been capped at both ends. Owing to their systematic and well-organized structure, they display high mechanical stamina, which makes them an ideal choice for biosensing applications [135, 136] . In addition, CNTs deliver a broad surface area for immobilizing a great number of BREs [137] . Thus, they are being commonly employed in detecting virusrelated biomarkers in biological samples. For instance, a FET-based assay was developed for recognizing tiny amounts of HCV employing SWCNT. PNA was used as the probe and detected 0.5 pM of the target particles [87] . In a different research work, a simple-to-use FET biosensor was projected for the quantification of aerosolized viruses (see Figure 22 ). The core strategy of this approach was the higher number of charge carriers and larger sizes of the antibody-antigen complexes compared to unbound antibodies or viruses. This fact led to the deposition of these big particles on a specific region of the substrate. In the case that this area overlaps with the SWCNT-modified channel of the transistor, a change will occur in the recorded current that signifies the existence of the virus [91] . The other category of surface functionalization materials is the TMDs [138] . They are single-layer semiconductors that are made up of two chalcogen atoms and a group IV, V, or VI transition metal component [139] . These single-layer hexagonal structures contain a direct bandgap that makes them suitable candidates for electronic applications [140] . One of the most popular two-dimensional TMDs-Molybdenum disulfide (MoS2)-has attracted attention in biomedical fields attributable to its superior electronic, chemical and mechanical characteristics [141] . This graphene-like arrangement has a width equal to a single cell, which results in its ultra-sensitive performance when used in biosensing platforms. They can be easily integrated into biosensors since they do not have any loose bond in their structure [142] . Today, they are broadly being employed especially in Chem/Bio-FETs [143] . For example, an accurate MoS2-FET genosensor was established for detecting Down syndrome. They modified MoS2 with gold nanoparticles in order to facilitate DNA immobilization. The device presented an ultra-sensitive performance by detecting down to 100 aM of the target DNA sequences [144] . Another easy-to-use and the precise system was designed using a MoS2-functionalized FET immunosensor for identifying Fibroblast growth factor 21 (FGF21)-a biomarker for fatty liver disease (NAFLD) detection. After introducing the sample containing the target analyte, and accordingly the production of Ab-Ag complexes, the detection occurred and a LoD of 10 fg·mL −1 was recorded. This device demonstrated a satisfactory selectivity even in complex serum samples [145] . A DNA biosensor based on a MoS2-based FET was introduced which employed phosphorodiamidate morpholino oligos (PMO)-DNA hybridization as their detection strategy. Negatively charged MoS2 was drop-casted on the positive-charge-baring sensing area and attached via electrostatic interactions. Next, the immobilization of PMOs took place, which enabled an ultra-sensitive detection. The low LoD (6 fM) of this device showed the outstanding capability of this structure in biosensing applications [146] . The use of TMDs in Chem/BioFETs is exemplified in these successful studies and many others [147] [148] [149] [150] , which confirms their high performance in detecting tiny biomolecules in complex human biofluids. CPs are one of the other appropriate choices for covering the surface of Chem/Bio-FETs since they are lightweight, cost-effective, highly scalable, easy-to-fabricate and have The other category of surface functionalization materials is the TMDs [138] . They are single-layer semiconductors that are made up of two chalcogen atoms and a group IV, V, or VI transition metal component [139] . These single-layer hexagonal structures contain a direct bandgap that makes them suitable candidates for electronic applications [140] . One of the most popular two-dimensional TMDs-Molybdenum disulfide (MoS 2 )-has attracted attention in biomedical fields attributable to its superior electronic, chemical and mechanical characteristics [141] . This graphene-like arrangement has a width equal to a single cell, which results in its ultra-sensitive performance when used in biosensing platforms. They can be easily integrated into biosensors since they do not have any loose bond in their structure [142] . Today, they are broadly being employed especially in Chem/BioFETs [143] . For example, an accurate MoS 2 -FET genosensor was established for detecting Down syndrome. They modified MoS 2 with gold nanoparticles in order to facilitate DNA immobilization. The device presented an ultra-sensitive performance by detecting down to 100 aM of the target DNA sequences [144] . Another easy-to-use and the precise system was designed using a MoS 2 -functionalized FET immunosensor for identifying Fibroblast growth factor 21 (FGF21)-a biomarker for fatty liver disease (NAFLD) detection. After introducing the sample containing the target analyte, and accordingly the production of Ab-Ag complexes, the detection occurred and a LoD of 10 fg·mL −1 was recorded. This device demonstrated a satisfactory selectivity even in complex serum samples [145] . A DNA biosensor based on a MoS 2 -based FET was introduced which employed phosphorodiamidate morpholino oligos (PMO)-DNA hybridization as their detection strategy. Negatively charged MoS 2 was dropcasted on the positive-charge-baring sensing area and attached via electrostatic interactions. Next, the immobilization of PMOs took place, which enabled an ultra-sensitive detection. The low LoD (6 fM) of this device showed the outstanding capability of this structure in biosensing applications [146] . The use of TMDs in Chem/BioFETs is exemplified in these successful studies and many others [147] [148] [149] [150] , which confirms their high performance in detecting tiny biomolecules in complex human biofluids. CPs are one of the other appropriate choices for covering the surface of Chem/BioFETs since they are lightweight, cost-effective, highly scalable, easy-to-fabricate and have adjustable properties [151] . These functional materials have exceptional electrochemical characteristics, high electrical conductivity, mechanical stamina and thus are suitable for being used in biosensors as transducers [152] . Controlling their configuration and the use of dopants in the structure of CPs can further improve their performance by providing a large surface-to-volume ratio and boosted electrocatalytic behavior [153] . They can be utilized in the form of NWs or nanotubes on the sensing region of biosensors in order to enhance their sensitivity [154] . Modulating the CPs surface for optimized biomolecule linkages make their use in sensing platforms feasible [155] . For example, a very recent study reported the development of a conducting polymer nanotubes-functionalized FET aptasensor for dopamine (DA) recognition. Tailor-made aptamers were immobilized on the surface of carboxylated polypyrrole nanotubes (CPNTs), which resulted in the detection of as low as 100 pM of the DA. Controlling the diameter of CPNTs was an important feature, which the authors took into account while constructing this device. It was reported that the small structures demonstrated higher sensitivity and specificity in comparison to the wider ones since they delivered a large available area [156] . In order for Chem/BioFETs to have a precise and specific detection of antigen, antibody, nucleic acid, etc., their surface should be functionalized with tailored BREs. They operate based on the affinity between the antigen-antibody or DNA hybridization. Immobilizing specific BREs in their optimum arrangement enables the production of complementary complexes, which in turn change the conductance of the channel region. Generally, Chem/BioFETs can be categorized into three main groups of Immuno-, geno and apta-sensors. Antibodies against the viral/bacteria-related antigens, complementary DNA/RNA probes against the genomic material of the pathogen and tailor-made aptamers can be immobilized on the surface of modified FET devices in order to make them capable of capturing the desired target biomolecules. Antibody/antigen-immobilized FET-based biosensors -so-called immunosensors-are one of the most preferred systems for identifying either pathogen-specific antigens or produced antibodies in the host body in response to the pathogen attack. For example, the most recent research work for the identification of SARS-CoV-2 was carried out utilizing a FET-based biosensor decorated with ultra-selective antibodies to capture viral spike proteins. It could recognize as low as 100 fg/mL of the analyte in clinical transport medium [157] . A portable immunosensor was developed for sensing HIV-1. This singlemolecule detection was carried out using an electrolyte-gated FET modified with antibodies against the capsid protein of HIV-1 p24 [105] . In another study, a GFET was designed using 1-pyrenebutanoic acid succinimidyl ester (PBASE) as the linker to immobilize specific antibodies for detecting the whole viruses. This strategy was successful enough to spot down to 47.8 aM of the target biomolecules [111] . The efficiency of these investigations and many others [89, [91] [92] [93] 103, [106] [107] [108] 110, 115] acknowledge the capability of FET-based immunosensors in detecting infectious diseases. Nucleic acid-based sensing systems or genosensors are the next widespread category of FET biosensors. The matching DNA or RNA of the virus, bacteria or any other pathogen is immobilized on the sensing area of the FET, and in the case that the target DNA/RNA is present in the sample, a signal is recorded as an indicator of the detection. For instance, a pioneering DNA biosensor was fabricated employing a SiNW-FET for HBV recognition. The probes were stabilized on the surface of (3-Aminopropyl) triethoxysilane (APTES)-functionalized nanowires. Due to the use of the rolling circle amplification strategy, a long strand of DNA was produced after introducing the targets. Therefore, an amplified electronic signal was recorded which enabled the detection of 1 fM of the target DNAs [90] . Another genosensing platform was proposed by Lee et al. They immobilized oligonucleotides on the surface of gold electrodes in order to detect the attachment of avian influenza virus sequences and achieved an LoD of 100 pM as seen in Table 1 [88] . In another effort, DNA was immobilized on CMOS-based ISFETs as BREs to detect Plasmodium falciparum. In this work, an adapted version of loop-mediated isothermal amplification (LAMP), called pH-LAMP, was employed, which enables ISFETs to detect pH variations during nucleic acid amplification. This CMOS-based device presented an outstanding performance, which shows its potential for being used as a PoC test of malaria [116] . Aptamers are the other group of selective BREs, which have been used in several studies related to FET-biosensor. They are popular for ultra-sensitive sensing, particularly when they are incorporated with nanoparticles. As an example, an aptasensor was established for detecting HPV employing an rGO-FET. The pyrene molecules acted as linkers for the successful immobilization of RNA aptamers on the surface of the sensor. This real-time detection was able to sense down to 1.75 nM of HPV-16 E7 [109] . Another aptamer-functionalized Chem/BioFET was constructed to identify Plasmodium falciparum glutamate dehydrogenase in serum specimens. A specific aptamer was designed to capture the target pathogen precisely. An LoD of 48.6 pM was recorded that demonstrates this device holds the potential for detecting malaria even in asymptomatic patients [45] . Other types of BREs have been used for functionalizing Chem/BioFETs such as PNAs, sialoglycans, sialoglycopeptides, or even bacteriophages. For instance, an on-chip bacteria sensing system was reported, which used bacteriophages as bioreceptors for spotting a particular strain of E. coli. The potassium ions released from inside the bacterial cells due to phage infection was measured by a CMOS-based ISFET with polyvinyl chloride (PVC)-based potassium-sensitive membrane. This sensor could detect as low as 48.6 pM of the target biomolecules in below 30 min [22] (As seen in Table 1 ). PNAs are the other novel type of BREs that have been used in a study for recognizing HCV. This SWNT-FET-based device was able to conduct a pM level detection [158] . Sialoglycans are also one of the desirable BREs that can be used in designing novel pathogen biosensors. They can mimic the natural host-cell surface and enhance the performance of the biosensor. For example, Ono and colleagues developed an influenza GFET-biosensing platform using sialic acid for coating the surface of the sensing region. Owing to the affinity of the virus's HA molecules to this glycoprotein, the HA-sialic acid complexes are generated. Besides, neuraminidase (NA) interacts with these complexes, which result in the detection of the virus [113] . After preparation of the Chem/BioFET structure and modification and functionalization of the sensing surface according to the desired application, the parameters of Chem/BioFETs should be controlled and measured using electrical devices, which might be laboratory equipment like a potentiostat and a semiconductor parameter analyzer [87, 89, 91, 94] or integrated circuits [20, 22, 23, 88, 116] . This section gives an overview of readout techniques. Herein, the main focus is on the CMOS-based integrated circuits, which can pave the way for the development of affordable and handheld PoC devices. If the Chem/BioFETs are adapted to CMOS technology, it would be possible to miniature them together with the circuits of the required signal amplifiers, filters, multiplexers and analog-to-digital converters (ADCs) on a single chip. CMOS technology offers the great advantages of small size, lightweight, low cost, fast response, high spatiotemporal resolution, low power consumption, good noise immunity and high level of integration. Table 2 compares various readout circuits reported for Chem/BioFET sensors, especially CMOS-based ones. In 1999, Bausells et al. [159] focused on the fabrication of ISFETs in an unmodified CMOS process (standard CMOS process following the exact steps for MOSFET fabrication) and showed that it is possible to integrate sensing and electronic functions. They designed an integrated ISFET-amplifier circuit by employing standard cells from the CMOS process. Since many efforts have been made to fabricate ISFETs in CMOS technology, most of the circuits reported in Table 2 take advantage of ISFETs. Although many of them are used for pH measurement using ISFETs, they are potentially useful for reading the output parameters of Chem/BioFETs. Furthermore, as seen in both Tables 1 and 2 , ISFETs [20, 22, 23, 88, 116] are also useful for the detection of infectious agents. For instance, Rothberg et al. [20] presented a scalable CMOS-based ISFET sensor architecture for DNA sequencing of bacterial genomes including V. fischeri, E. coli, and R. palustris by measuring the pH variations during DNA sequencing. In other efforts, Malpartida-Cardenas et al. [116] and Lee et al. [88] reported CMOS-based ISFETs for the diagnosis of P. falciparum and H5N1 AIV through DNA sensing, respectively. As seen in Table 2 , Chem/BioFETs can be biased in different operation regions, which provide various types of readout circuits with different features. So, before introducing the readout circuits, it is required to take a look at the measurement principles in these operation regions. As aforementioned, among various Chem/BioFETs, the equations of ISFETs have been theorized perfectly which were briefly reviewed in Section 2. The output current of ISFET in the linear region was expressed by Equation (1) where the threshold voltage follows Equation (5) . However, Since the gate of ISFET is in contact with electrolyte with no metal in its vicinity, internal source and drain resistances (R s and R d ) are formed based on the actual geometry of the device in such a way that the actual drain-source voltage and the gate-source voltage of the ISFET are equal to V DS,ISFET = V DS − (R s + R d )I D and V GS,ISFET = V GS − R s I D and, consequently, the sensitivity is declined [160] . A technological approach to solve this problem is shortening the length of the source and drain diffusions, which implies new technologies. However, using electronic readout circuits insensitive to series resistances is much easier. By biasing an ISFET at a constant I D with a constant V DS , V GS will adjust to compensate for a change in threshold voltage due to a pH variation [160] . Linear operation mode is one of the operational regions that can be used in currentmode circuits. If the ISFET is biased in the triode region with a low V DS , the output current mentioned by Equation (1) can be approximated by [32] : where V t(ISFET) is dependent on pH based on Equation (5) . So, I D has linear sensitivity to pH [32] : The width of the channel (W) biased in the triode region is determined by the gain requirements but at the expense of the occupied area and array density. Moreover, to reduce the second-order sources of non-linearity (like mobility degradation) as well as short-channel effects, the length of the transistor (L) should be long enough. The principle of measuring the threshold voltage of ISFET in the saturation region is similar to triode ISFET. Furthermore, some low-voltage low-power circuits are reported for the ISFETs operating in weak inversion, as a translinear element. Velocity saturation as a short-channel effect can also be used as a linear mode of operation for current-mode readout circuits. Considering V t(ISFET) follows Equation (5), the sensitivity of I D to pH is linear [32] : By comparing with Equation (10), it can be deduced that, in contrast to the triode region, the operation of the transistor in velocity saturation is insensitive to mobility (µ), V DS , and length (L) mismatches, especially when the minimum length is used. The transistor in velocity saturation naturally needs to be a short-channel device and small width is preferred to limit the biasing current [32] . The following subsections outline different circuits reported for measuring the outputs of Chem/BioFET. Many of the Chem/BioFET readout circuits involve non-differential measurement topology, which can have various configurations as described in the following subsections. One technique is controlling the variations of I D in a feedback loop and automatic adjustment of the potential of the RE, and thus of the liquid, with respect to the source and drain potentials. So, any change in V t will be compensated by the variation of V gs via the reference voltage of RE, V Ref . For instance, an automatically balanced bridge circuit [161] like Figure 23a can compensate a change in V t by changing V gs , via the RE (see Table 2 ). However, this technique forces the liquid sample to a certain potential while the liquid may not be grounded. Moreover, the asymmetrical impedance of the source and drain leads the system sensitive to static electricity and electric fields [160] . Furthermore, this approach is not suitable for measuring multiple ISFETs with one RE [188] . Georgiou et al. [189] in which the current of ISFET is compared and set with a reference current, IRef, in a feedback loop, and VOut is adjusted by the effective gate-source voltage of the ISFET. In another effort, Jamasb et al. [190] reported another circuit in which the voltage reference is set in a feedback loop. Since this biasing is not constant, an array structure with this configuration will require a distinct RE for each pixel leading to a complex setup. So, this technique is not a popular configuration [191] . CVCC configuration is the most popular one for the readout circuits of Chem/BioFET sensors in which Chem/BioFET current and drain voltage are constant and the source voltage varies with pH. This technique, which was proposed by Bergveld [160] , is an automatic adjustment of the source and drain potentials in respect of a constant liquid potential which can be accidentally the ground potential in practice. So, the best way is to ground the liquid utilizing a grounded reference. Source/drain follower circuit can provide these conditions and is the most convenient approach to detect the variations of ISFET threshold voltage [160] . CVCC configuration is immune to capacitive scaling of the pH signal at the floating gate of the ISFET. Moreover, the arrays designed based on this technique are compact and only need a switch and an ISFET for each pixel [191] . Figure 23b shows a programmable gate (PG)-ISFET readout circuit proposed by Georgiou et al. [189] in which the current of ISFET is compared and set with a reference current, I Ref , in a feedback loop, and V Out is adjusted by the effective gate-source voltage of the ISFET. In another effort, Jamasb et al. [190] reported another circuit in which the voltage reference is set in a feedback loop. Since this biasing is not constant, an array structure with this configuration will require a distinct RE for each pixel leading to a complex setup. So, this technique is not a popular configuration [191] . CVCC configuration is the most popular one for the readout circuits of Chem/BioFET sensors in which Chem/BioFET current and drain voltage are constant and the source voltage varies with pH. This technique, which was proposed by Bergveld [160] , is an automatic adjustment of the source and drain potentials in respect of a constant liquid potential which can be accidentally the ground potential in practice. So, the best way is to ground the liquid utilizing a grounded reference. Source/drain follower circuit can provide these conditions and is the most convenient approach to detect the variations of ISFET threshold voltage [160] . CVCC configuration is immune to capacitive scaling of the pH signal at the floating gate of the ISFET. Moreover, the arrays designed based on this technique are compact and only need a switch and an ISFET for each pixel [191] . Figure 24a shows a simple version of a source/drain follower using unsaturated ISFET [188] . The operational amplifier provides equal input voltages and so V R1 = V R3 and V R2 = V ds , which are constant (V R1 and V R2 are parts of constant V ref ). As a result, I d = V R3 /R 3 is also constant. Thus, V gs automatically adapt the source potential with respect to the ground to compensate the variation of ISFET threshold voltage, V t , and the output voltage accurately reproduces the changes in the oxide surface potential. The diodes at the output, which are practically light-emitting diodes (LEDs), provide a limitation of V Out , and thus the source voltage with respect to ground, and light up when the system is out of range. ISFET [188] . The operational amplifier provides equal input voltages and so VR1 = VR3 and VR2 = Vds, which are constant (VR1 and VR2 are parts of constant Vref). As a result, Id = VR3/R3 is also constant. Thus, Vgs automatically adapt the source potential with respect to the ground to compensate the variation of ISFET threshold voltage, Vt, and the output voltage accurately reproduces the changes in the oxide surface potential. The diodes at the output, which are practically light-emitting diodes (LEDs), provide a limitation of VOut, and thus the source voltage with respect to ground, and light up when the system is out of range. Figure 24b shows another source/drain follower that uses the instrumentation amplifier concept and unsaturated ISFET [160] . The inputs of the instrumentation amplifier are connected to a fixed voltage, IR1 and its output voltage is inversely proportional to the channel resistance of the ISFET. An operational amplifier amplifies the difference between the output voltage of the instrumentation amplifier and Vref, which is an adjustable reference voltage. The output of this amplifier injects a feedback current, If, into R2 and provides a constant Id and a constant Vds = IR1 by controlling the source voltage (VR2) and drain voltage (VR1 + R2). If is measured via the adjustable resistor R9. The source and drain potential in respect of ground follow a change in the effective input voltage V1 whose amplified version is available across R9 and is equal to VOut = (R9/R2)V1. The reference voltage, which should be independent of temperature, is adjusted in such a way that If = 0 when the ISFET is placed in a neutral buffer (pH = 7). A circuitry (not shown in Figure 24b ) was also added for temperature measurement and compensation of temperature drift in Vgs(T) for constant Id. As reported by Hammond et al. [192] , two source measure units (SMU1 and SMU2) on a parameter analyzer along with a feedback loop composed of a fixed resistor and two operational amplifiers can provide the bias condition of saturated ISFET and the RE can be biased at a suitable voltage by another SMU (SMU3). Nikkoo et al. [22] integrated a similar source/drain follower along with potassium-sensitive FET using CMOS technology for rapid detection of E. coli bacteria. In another effort, Ravezzi et al. [162] used a structure employing cascode current mirrors with output impedance to provide the ISFET drain current with low dependence on its Vds. Three operational amplifiers were adapted to the structure, two of which biased the ISFET at the triode region and the last one operated in the follower configuration to de-couple the output terminal from the biasing circuit. The infinite input impedance of a source/drain follower leads the circuit to not load the system during measurement. However, op-amps increase area occupation and power consumption. To decrease the power consumption and area occupation of array structures with a large number of pixels that employ op-amps, the readout circuit can be shared between pixels in the same row or column [63, 182, 183, 193, 194] . Figure 25a illustrates a Figure 24b shows another source/drain follower that uses the instrumentation amplifier concept and unsaturated ISFET [160] . The inputs of the instrumentation amplifier are connected to a fixed voltage, IR 1 and its output voltage is inversely proportional to the channel resistance of the ISFET. An operational amplifier amplifies the difference between the output voltage of the instrumentation amplifier and V ref , which is an adjustable reference voltage. The output of this amplifier injects a feedback current, I f , into R 2 and provides a constant I d and a constant V ds = IR 1 by controlling the source voltage (V R2 ) and drain voltage (V R1+R2 ). I f is measured via the adjustable resistor R 9 . The source and drain potential in respect of ground follow a change in the effective input voltage V 1 whose amplified version is available across R 9 and is equal to V Out = (R 9 /R 2 )V 1 . The reference voltage, which should be independent of temperature, is adjusted in such a way that I f = 0 when the ISFET is placed in a neutral buffer (pH = 7). A circuitry (not shown in Figure 24b ) was also added for temperature measurement and compensation of temperature drift in V gs (T) for constant I d . As reported by Hammond et al. [192] , two source measure units (SMU1 and SMU2) on a parameter analyzer along with a feedback loop composed of a fixed resistor and two operational amplifiers can provide the bias condition of saturated ISFET and the RE can be biased at a suitable voltage by another SMU (SMU3). Nikkoo et al. [22] integrated a similar source/drain follower along with potassium-sensitive FET using CMOS technology for rapid detection of E. coli bacteria. In another effort, Ravezzi et al. [162] used a structure employing cascode current mirrors with output impedance to provide the ISFET drain current with low dependence on its V ds . Three operational amplifiers were adapted to the structure, two of which biased the ISFET at the triode region and the last one operated in the follower configuration to de-couple the output terminal from the biasing circuit. The infinite input impedance of a source/drain follower leads the circuit to not load the system during measurement. However, op-amps increase area occupation and power consumption. To decrease the power consumption and area occupation of array structures with a large number of pixels that employ op-amps, the readout circuit can be shared between pixels in the same row or column [63, 182, 183, 193, 194] . Figure 25a illustrates a single column of n half-cells in an n × n array. Milgrew et al. [63] used this architecture and reported a CMOS sensor chip including a 16 × 16 pixel array of ISFETs for direct extracellular imaging. Some array structures [163, 195] are designed based on a standard pixel readout like Figure 25b which is similar to CVCC and consists of an ISFET and two switches. In another effort, as mentioned in Table 2 , Malpartida-Cardenas et al. [116] used a 64 × 64 array whose pixels were implemented as a source follower configuration and convert pH to voltage and employed this sensor for plasmodium falciparum malaria diagnosis and artemisininresistance detection. Several papers integrated active pixel sensors (APS) using ISFETs by employing the ISFETs as the standard buffer [175, 176] or the replacement of the photodiode by the ISFET [164, 165] (by using a charge transfer technique). Huang et al. [176] proposed a dual-mode sensor by integrating a CMOS image sensor with the ISFET as the standard buffer to achieve accurate pH detection towards DNA sequencing. The dual-mode pixel is depicted in Figure 25c . The circuit shown in gray is added to an ISFET pixel to provide optical sensing along with pH measurement. The poly-gate of ISFET (SF) is connected to the top metal and Si3N4 passivation layer (as ion-sensitive membrane of ISFET). They also employed correlated double sampling to mitigate pixel-to-pixel non-uniformity like threshold voltage mismatch. Current-mode readout techniques [31, 32, 172, 196, 197] have also attracted the attention of researchers. In this approach, the output current of ISFET is measured, which can take the advantages of current-mode techniques and is also compatible with weak inversion operation, as well as linear and velocity saturation regions [191] . Rothberg et al. [194] improved FET pixel and array designs to achieve high accuracy and measurement sensitivity as well as small pixel sizes and dense arrays. Different pixel designs are proposed by this group based on both p-channel ISFETs and n-channel ISFETs. The same group [20] fabricated a chip with 1.5 M, 7.2 M and 13 M ISFETs (see Table 2 ) and used it for simultaneous detection of independent DNA sequencing of three bacterial genomes (V. fischeri, E. coli, and R. palustris). There are also some other techniques that are based on CVCC method, but the output node of the circuit is connected to ISFET floating gate through a capacitor or switch. For instance, Hu et al. [167] designed a circuit using feedback and a low-leakage switching scheme and overcame the problems of transconductance reduction due to capacitive division and DC offset due to trapped charge. Chan et al. [169] also used an averaging array based on a global negative current feedback technique to regulate the undefined threshold voltages of ISFETs. Some array structures [163, 195] are designed based on a standard pixel readout like Figure 25b which is similar to CVCC and consists of an ISFET and two switches. In another effort, as mentioned in Table 2 , Malpartida-Cardenas et al. [116] used a 64 × 64 array whose pixels were implemented as a source follower configuration and convert pH to voltage and employed this sensor for plasmodium falciparum malaria diagnosis and artemisinin-resistance detection. Several papers integrated active pixel sensors (APS) using ISFETs by employing the ISFETs as the standard buffer [175, 176] or the replacement of the photodiode by the ISFET [164, 165] (by using a charge transfer technique). Huang et al. [176] proposed a dual-mode sensor by integrating a CMOS image sensor with the ISFET as the standard buffer to achieve accurate pH detection towards DNA sequencing. The dual-mode pixel is depicted in Figure 25c . The circuit shown in gray is added to an ISFET pixel to provide optical sensing along with pH measurement. The poly-gate of ISFET (SF) is connected to the top metal and Si 3 N 4 passivation layer (as ion-sensitive membrane of ISFET). They also employed correlated double sampling to mitigate pixel-to-pixel non-uniformity like threshold voltage mismatch. Current-mode readout techniques [31, 32, 172, 196, 197] have also attracted the attention of researchers. In this approach, the output current of ISFET is measured, which can take the advantages of current-mode techniques and is also compatible with weak inversion operation, as well as linear and velocity saturation regions [191] . The weak inversion region provides drain currents in the order of nano-ampers and below that is suitable for designing low-power circuits. In addition, the region has the highest transconductance to current ratio and so the maximum intrinsic voltage gain [31] . Low V ds required for saturation, minimum gate capacitance and low gate voltage in this region are the other advantages of weak inversion [65] . Moreover, the exponential relationship of V gs -I d allows for using bipolar circuit techniques like log-domain filters and translinear circuits for ISFET applications leading to novel biochemical systems. For example, Figure 26a illustrates a hydrogen cell (Hcell) based on a translinear operation reported by Shepherd et al. [31, 198] whose output current is directly proportional to hydrogen ion [H + ] concentration. By setting I b1 = I b2 and considering K chem = exp(−γ/nV th ) and Equation (7), it can be proved that [31] : ported by Shepherd et al. [31, 198] whose output current is directly proportional to hydrogen ion [H + ] concentration. By setting Ib1 = Ib2 and considering Kchem = exp(−γ/nVth) and Equation (7), it can be proved that [31] : As another technique, Georgiou et al. [197] presented a log domain chemical filter utilizing an ISFET biased in weak inversion. Figure 26b shows a log-domain filter with an ISFET used at its input. The filter parameters like gain and cut-off frequency can be dependent on the ion concentration of the analyte. An array configuration was used by Miscourides et al. [32] in which direct controlling of the Vds of each device gets access to an individual pixel. Each drain row is connected to a generic current conveyor (CC), which leads the voltage of that row to be constant at VDR and guarantees the generation of an output current depending only on Vgs during readout of each pixel. A 128 × 128 current-mode ISFET array with in-pixel calibration is proposed by Zeng et al. [174] , which takes advantage of a CC, auto zeroing technique and sample and hold (see Table 2 ). In another effort, Pookaiyaudom et al. [199] embedded a CC type 2 (CCII + ) with two ISFETs as its input transistors. As another technique, Georgiou et al. [197] presented a log domain chemical filter utilizing an ISFET biased in weak inversion. Figure 26b shows a log-domain filter with an ISFET used at its input. The filter parameters like gain and cut-off frequency can be dependent on the ion concentration of the analyte. An array configuration was used by Miscourides et al. [32] in which direct controlling of the V ds of each device gets access to an individual pixel. Each drain row is connected to a generic current conveyor (CC), which leads the voltage of that row to be constant at V DR and guarantees the generation of an output current depending only on V gs during readout of each pixel. A 128 × 128 current-mode ISFET array with in-pixel calibration is proposed by Zeng et al. [174] , which takes advantage of a CC, auto zeroing technique and sample and hold (see Table 2 ). In another effort, Pookaiyaudom et al. [199] embedded a CC type 2 (CCII + ) with two ISFETs as its input transistors. A configuration was used by Miscourides et al. [32] in which the ISFETs were biased in the velocity saturation region and includes a pixel switch to turn on only one pixel at any time. The higher drain current in the velocity saturation region in comparison to the triode region would make it unsustainable to simultaneously output the currents of all column pixels (see Equations (10) and (11)). To compensate the offset, the same group [200] extended their current-mode array to include a PG inside each pixel. As a continuation of these works, this group compares these two configurations with a voltagemode source-follower configuration. Figure 26d shows the schematic of a system including a current-mode configuration in a 64 × 200 array, current-mode PG pixel architecture in a 64 × 200 array, voltage-mode pixel structure in a 64 × 128 array, current conveyor, transimpedance amplifier, buffer, two on-chip and two off-chip ADC. The two currentmode configurations showed better linearity and smaller size than the voltage-mode circuit and they concluded that the current-mode approach provides the best overall performance [171] . An integrate-and-fire topology with address event representation (AER) was used by Georgiou et al. [166] to encode the pH-sensitive current in frequency. Despite its low power consumption (157 nW at pH = 7), the signal processing using specific ADCs in the spike domain makes this technique complex. The same group [173] used a similar current-mode pixel architecture along with an averaging mirror for robust measurement and a ring oscillator for converting the current to frequency. In some current-mode circuits [172, 201, 202] , a current feedback is used for stable DC operation. For example, Figure 26c shows a current-mode readout with global feedback proposed by Premanode et al. [172] . Juffali et al. [203] proposed another circuit based on translinear operation employing a division circuit and two ISFETs that can directly measure the ratio of urea to creatinine (an important marker for detection of pre-renal failure). Figure 27a illustrates the ISFET based translinear divider. In another effort, Kalofonou et al. [204] proposed a ratiometric approach of DNA methylation using ISFET in a translinear circuit (as depicted in Figure 27b ). This sensor can determine the level of aberrancy of methylation between unmethylated and highly methylated genes and identify early signs of human neoplasias through blood circulation. A configuration was used by Miscourides et al. [32] in which the ISFETs were biased in the velocity saturation region and includes a pixel switch to turn on only one pixel at any time. The higher drain current in the velocity saturation region in comparison to the triode region would make it unsustainable to simultaneously output the currents of all column pixels (see Equations (10) and (11)). To compensate the offset, the same group [200] extended their current-mode array to include a PG inside each pixel. As a continuation of these works, this group compares these two configurations with a voltage-mode source-follower configuration. Figure 26d shows the schematic of a system including a current-mode configuration in a 64 × 200 array, current-mode PG pixel architecture in a 64 × 200 array, voltage-mode pixel structure in a 64 × 128 array, current conveyor, transimpedance amplifier, buffer, two on-chip and two off-chip ADC. The two current-mode configurations showed better linearity and smaller size than the voltage-mode circuit and they concluded that the current-mode approach provides the best overall performance [171] . An integrate-and-fire topology with address event representation (AER) was used by Georgiou et al. [166] to encode the pH-sensitive current in frequency. Despite its low power consumption (157 nW at pH = 7), the signal processing using specific ADCs in the spike domain makes this technique complex. The same group [173] used a similar currentmode pixel architecture along with an averaging mirror for robust measurement and a ring oscillator for converting the current to frequency. In some current-mode circuits [172, 201, 202] , a current feedback is used for stable DC operation. For example, Figure 26c shows a current-mode readout with global feedback proposed by Premanode et al. [172] . Juffali et al. [203] proposed another circuit based on translinear operation employing a division circuit and two ISFETs that can directly measure the ratio of urea to creatinine (an important marker for detection of pre-renal failure). Figure 27a illustrates the ISFET based translinear divider. In another effort, Kalofonou et al. [204] proposed a ratiometric approach of DNA methylation using ISFET in a translinear circuit (as depicted in Figure 27b ). This sensor can determine the level of aberrancy of methylation between unmethylated and highly methylated genes and identify early signs of human neoplasias through blood circulation. In 2009, Wong et al. [205] proposed discrete ISFET logic for the detection of chemical reaction threshold which is useful for applications like detecting a specific gene in a DNA sequence where there is no need to measure the exact value of pH. For example, the switching threshold of an inverter can give a yes/no answer based on the pH variations. Other components like a switch [179, 206] , Schmitt trigger [207] or a NAND gate [40] can also be used as comparators. In 2009, Wong et al. [205] proposed discrete ISFET logic for the detection of chemical reaction threshold which is useful for applications like detecting a specific gene in a DNA sequence where there is no need to measure the exact value of pH. For example, the switching threshold of an inverter can give a yes/no answer based on the pH variations. Other components like a switch [179, 206] , Schmitt trigger [207] or a NAND gate [40] can also be used as comparators. Figure 28a-c illustrates three configurations of an ISFET inverter with only one ntype or p-type ISFET or a pair of both. For example, Al-Ahdal et al. [179, 206] used a complimentary pair of p-type and n-type ISFETs sharing the same ion-sensitive membrane as shown in Figure 28a and formed an ISFET-based chemical switch. Nabovati et al. [180] these switches in each pixel of an 8 × 8 array and achieve a wide pH range from 1 to 14 and the sensitivity of 50 mV/pH (see Table 2 ). Figure 28a-c illustrates three configurations of an ISFET inverter with only one ntype or p-type ISFET or a pair of both. For example, Al-Ahdal et al. [179, 206] used a complimentary pair of p-type and n-type ISFETs sharing the same ion-sensitive membrane as shown in Figure 28a and formed an ISFET-based chemical switch. Nabovati et al. [180] these switches in each pixel of an 8 × 8 array and achieve a wide pH range from 1 to 14 and the sensitivity of 50 mV/pH (see Table 2 ). (a) (b) (c) Figure 28 . Three configurations of ISFET inverters: (a) p-type and n-type ISFET sharing the same membrane; (b) p-type ISFET with membrane and n-type MOSFET; (c) n-type ISFET with membrane and p-type MOSFET. An mentioned above, the inverter with complementary ISFETs [208, 209] can be the core of a compact pH-to-time converter capacitively coupled to a triangular wave whose switching point and, consequently, its output pulse width is modulated with pH. Pulsewidth modulation (PWM)-based topologies is one of the suitable structures that allow inpixel quantization and thus improve the SNR [191] . Wang et al. [178] proposed an ISFET pH-to-time sensor integrated with a fine on-chip time-to-digital converter (TDC) as the ADC with a thermometer-to-binary coder and a delay line. In another effort, Moser et al. [177, 210] reported a pH-to-time converter based on APS as depicted in Figure 29a . This circuit modulates pH to pulse-width by using a periodic reset scheme and discharging a capacitor through the ISFET. Jiang et al. [23, 211] proposed a subthreshold pH-to-time-to-voltage conversion (pH-TVC) readout structure by employing pixel-level calibration and digital double sampling. As a result, the sensor can mitigate non-ideal effects, like passivation attenuation, parasitic capacitance and trapped charge. As demonstrated in Figure 29b , Mn0 and Mn1 are an ISFET and a row-selected transistor, and the other parts are shared by pixels in each column. Mp0 and S0 (including complementary NMOS and PMOS transistor pair) are a pre-charge switch and a transfer switch, respectively. C0, the source follower Mn2 and current source I0 are, in turn, used as integrator, buffer and the biasing circuit. A ramp generator, a singleslope ADC and an SRAM group are also utilized along with the pH-TVC readout circuit. Any change in pH results in a shift in the VOut. It can be proved that ΔVOut is obtained by: where Gm, Δt, ΔVchem, and A stand for the ISFET transistor transconductance, the charge integration time, pH-related potential change, and the attenuation factor, respectively. The amplification factor, (Δt/C0)Gm, is used to compensate the passivation sensitivity attenuation effect. This group [23] used this sensor for E. coli detection and achieved the sensitivity and resolution of 118.7 mV/pH and 0.01 pH, respectively (see Table 2 ). An mentioned above, the inverter with complementary ISFETs [208, 209] can be the core of a compact pH-to-time converter capacitively coupled to a triangular wave whose switching point and, consequently, its output pulse width is modulated with pH. Pulsewidth modulation (PWM)-based topologies is one of the suitable structures that allow in-pixel quantization and thus improve the SNR [191] . Wang et al. [178] proposed an ISFET pH-to-time sensor integrated with a fine on-chip time-to-digital converter (TDC) as the ADC with a thermometer-to-binary coder and a delay line. In another effort, Moser et al. [177, 210] reported a pH-to-time converter based on APS as depicted in Figure 29a . This circuit modulates pH to pulse-width by using a periodic reset scheme and discharging a capacitor through the ISFET. Several differential architectures have been developed that measure the difference of the output signals of two ISFETs with the same REs. Differential techniques offer the advantages of temperature and long-term drift compensation as well as the elimination of common-mode noise. Moreover, these techniques can solve the problems of the unstable electrolyte-RE potential and the instability caused by the membrane layers of the ISFETs. Lack of a solid-state RE is one of the issues in the field of solid-state chemical potentiometric sensors because they need to be combined with a liquid-filled RE whose stable lifetime is limited. Thus, in practice, a small sensor probe and a rather large RE are used together restricting the possibility of measuring in small sample volumes. For this reason, Jiang et al. [23, 211] proposed a subthreshold pH-to-time-to-voltage conversion (pH-TVC) readout structure by employing pixel-level calibration and digital double sampling. As a result, the sensor can mitigate non-ideal effects, like passivation attenuation, parasitic capacitance and trapped charge. As demonstrated in Figure 29b , M n0 and M n1 are an ISFET and a row-selected transistor, and the other parts are shared by pixels in each column. M p0 and S 0 (including complementary NMOS and PMOS transistor pair) are a pre-charge switch and a transfer switch, respectively. C 0 , the source follower M n2 and current source I 0 are, in turn, used as integrator, buffer and the biasing circuit. A ramp generator, a single-slope ADC and an SRAM group are also utilized along with the pH-TVC readout circuit. Any change in pH results in a shift in the V Out . It can be proved that ∆V Out is obtained by: where G m , ∆t, ∆V chem , and A stand for the ISFET transistor transconductance, the charge integration time, pH-related potential change, and the attenuation factor, respectively. The amplification factor, (∆t/C 0 )G m , is used to compensate the passivation sensitivity attenuation effect. This group [23] used this sensor for E. coli detection and achieved the sensitivity and resolution of 118.7 mV/pH and 0.01 pH, respectively (see Table 2 ). Several differential architectures have been developed that measure the difference of the output signals of two ISFETs with the same REs. Differential techniques offer the advantages of temperature and long-term drift compensation as well as the elimination of common-mode noise. Moreover, these techniques can solve the problems of the unstable electrolyte-RE potential and the instability caused by the membrane layers of the ISFETs. Lack of a solid-state RE is one of the issues in the field of solid-state chemical potentiometric sensors because they need to be combined with a liquid-filled RE whose stable lifetime is limited. Thus, in practice, a small sensor probe and a rather large RE are used together restricting the possibility of measuring in small sample volumes. For this reason, many research efforts have been dedicated to a differential measurement between an ISFET and an identical reference FET (REFET), which has a very low (ideally zero) sensitivity to the ion concentration under measurement. In this case, a metal wire can be used for grounding the sample solution [188] . So, a complete integrated ISFET-based sensor can be implemented by a differential structure composed of an ISFET and a REFET biased by a common counter-electrode as a pseudo-reference electrode (PRE) (Figure 30a ) [188] . In this arrangement, the conventional RE is replaced by a PRE made of a noble metal, such as gold and platinum, to define the potential of the electrolyte without the need for any external RE. Covering the gate oxide of an ISFET within an additional ion insensitive membrane like a polymer [212, 213] or chemical modification of the original gate oxide surface sites [214] are the most popular techniques to create a low-sensitive REFET. For practical reasons, bulk and source connections are usually short-circuited [213] . However, Bergveld et al. [46] , in their seminal works, used bulk feedback to control the depletion charge in the bulk. Moreover, drift and different electrical properties of REFET and ISFET are some of the issues of this technique [193, 215, 216] . The DC bias of REFET and ISFET should be the same in such a way that they behave electrically identical. Chudy et al. [217] proposed to use a modified ISFET with additional membranes (CHEMFET) of which the outer membrane comprising a buffer component for the ion measurement. In a differential CHEMFET/REFET system, the electrically identical REFET with the same membrane does not contain such a buffer. ISFETs (see Table 2 ). Chodavarapu et al. [218] proposed another differential architecture for pH measurement including a gold PRE and a pair of ISFET operational transconductance amplifiers (IOTAs), each composed of an ISFET as its input. The ISFETs used in both IOTAs are identical, but different sizes of the p-MOSFET loads used in IOTAs cause variations in the sensitivity of these two IOTAs (50 mV/pH and 30 mV/pH). They could achieve a sensitivity of 40-45 mV/pH. Figure 30 . (a) A differential ISFET/reference FET (REFET) measuring system; (b) a differential pH-measurement pixel with ISFET and REFET for array structure; (c) ISFET/REFET voltage-clamped configuration; (d) a chemical Gilbert cell; (e) a ΣΔ ISFET readout circuit using differential measurement. Hammond et al. [193] reported a system-on-chip (SOC) digital pH meter containing on-chip programmable voltage references and multiplexers controlled by a specially designed 8-bit microcontroller for use in a wireless diagnostic capsule and achieved a sensitivity of 37 bits/pH within an operating range of 7 pH units. Figure 30b shows the analog part of this differential ISFET/REFET pH-measurement circuit with a common PRE that includes two source-drain-follower configurations for the ISFET and REFET whose outputs are given to an instrumentation amplifier. In another effort, a similar differential Figure 30 . (a) A differential ISFET/reference FET (REFET) measuring system; (b) a differential pH-measurement pixel with ISFET and REFET for array structure; (c) ISFET/REFET voltage-clamped configuration; (d) a chemical Gilbert cell; (e) a Σ∆ ISFET readout circuit using differential measurement. In 1989, Wong and White [184] proposed a CMOS-integrated op-amp for pH measurement which had an ISFET input and a feedback loop to a MOSFET. Then, they differentially amplified the outputs of two ISFET operational amplifiers with a PRE. In this primary implementation, a special coating on the gate of ISFETs was used to achieve different sensitivities and an ISFET submerged in a buffer solution of known pH played the role of a reference device. One of these ISFET-op-amps was composed of an ISFET with a Ta 2 O 5 /SiO 2 gate and the other one included a SiO x N y /Si 3 N 4 /SiO 2 -gate ISFET with the sensitivity of 58-59 mV/pH and 18-20 mV/pH, respectively. The whole device could provide 40-43 mV/pH sensitivity and cancel common temperature effects as well as drift in both ISFETs (see Table 2 ). Chodavarapu et al. [218] proposed another differential architecture for pH measurement including a gold PRE and a pair of ISFET operational transconductance amplifiers (IOTAs), each composed of an ISFET as its input. The ISFETs used in both IOTAs are identical, but different sizes of the p-MOSFET loads used in IOTAs cause variations in the sensitivity of these two IOTAs (50 mV/pH and 30 mV/pH). They could achieve a sensitivity of 40-45 mV/pH. Hammond et al. [193] reported a system-on-chip (SOC) digital pH meter containing onchip programmable voltage references and multiplexers controlled by a specially designed 8-bit microcontroller for use in a wireless diagnostic capsule and achieved a sensitivity of 37 bits/pH within an operating range of 7 pH units. Figure 30b shows the analog part of this differential ISFET/REFET pH-measurement circuit with a common PRE that includes two source-drain-follower configurations for the ISFET and REFET whose outputs are given to an instrumentation amplifier. In another effort, a similar differential structure was presented by Palan et al. [185] comprising two sources/drain follower circuits and a voltage-to-current converter (V/I). ISFET 1 and ISFET 2 were composed of Si 3 N 4 and SiO 2 ion-sensitive layers with the sensitivity of 52-58 mV/pH and 24-36 mV/pH, respectively, and implemented in a 2.5 µm CMOS technology. The simulation results showed that this interface circuit could provide a precision of ±0.15 pH (see Table 2 ). An example of a pseudo-differential ISFET-REFET topology is the voltage-clamped circuit showed in Figure 30c [219] , which can provide a fixed electrical bias and can operate in either weak or strong inversion. In another effort, Sohbati et al. [220] implemented an ISFET/REFET sensing front-end as part of an input differential pair. The same group [221] also proposed a pH-to-digital converter using two current comparator-based circuits including ISFET and REFET in each of which the output node is connected to the floating gate of FET. In another work, Liu et al. [181] proposed a differential topology based on the CVCC principle controlled with feedback to the floating gate of ISFET. A Σ∆ ISFET readout circuit using differential current-mode measurement is also reported by Nabovati et al. [186] , which is depicted in Figure 30e . The ISFETs depicted in Figure 30e operate in the linear region and the circuit works in three phases: (1) Reset, (2) evaluation, and (3) sampling. During the reset phase activated by RST and RST, the value of C int capacitor is set to the common-mode voltage, V cm . During the evaluation phase, the clock Φ 1 is activated and the ISFET current charges the C int . Combining Equations (1) and (5), we can deduce that the ISFET current in this region is proportional to the pH value. The current differential scheme increases sensitivity. The second ISFET (IS 2 ) is a reference whose pH value is held at 7. In the sampling phase, the circuit is connected to the output for sampling. A charge to digital converter converts the output voltage to digital. As another technique, a chemical Gilbert cell is demonstrated in Figure 30d . The differential pair includes two ISFETs that can be considered as a chemical translinear circuit [187] . This circuit is appropriate for applications that require differential monitoring in small volumes and several chambers, like studying more than one gene in DNA detection. Lee et al. [88] proposed a CMOS device that directly measures the electrostatic induction of molecular charges in the working electrode with improved SNR and without any conversion loss. As seen in Figure 14 , both working electrodes are connected to a voltage buffer circuit with high input impedance (due to employing a transistor with an isolated gate) and their voltages are within the operating range of the buffer circuit. The buffer transfers the induced charges in working electrodes to a fully differential switched-capacitor integrator followed by an ADC for the accumulation and digitization of the signal. Trapped charges, noise and temperature sensitivity are some of the non-idealities that exist in ISFET measurements. This sub-section reviews some solutions to deal with them. The accumulation of trapped charge on the gate and passivation layer is one of the non-idealities that occurs during the fabrication of floating gate ISFETs in the standard CMOS process and causes a large unpredictable change in the threshold voltage of ISFET. UV radiation and bulk substrate biasing are the most convenient methods for the removal of the excess charge. The UV radiation can reach the inner polysilicon through a small aperture formed on top of the ISFET and excites the trapped charge that charges into the bulk region. This technique does not need any additional circuitry and can be employed for matching the electrical characteristics of ISFET pixels in an array structure. By the elimination of the mismatch between pixels threshold voltage, a single RE can be utilized for biasing the entire array [222] . Another technique is to use hot-electron injection, which can be adapted for threshold voltage programming. The operating point of ISFET can be calibrated by adding the electron to the floating gate and raising the threshold voltage [223] . However, this technique cannot decline the threshold voltage. Thus, electron tunneling is proposed by Al-Ahdal et al. [224] to eliminate electrons from the floating gate of the ISFET. Georgiou et al. [225] reported another approach to program the floating gate of the ISFET by using a capacitively coupled floating gate, which allows the tenability of the operating point and the operation of the device within a tolerable gate voltage range by tuning the operating point. Yan et al. [168] also used two extra programmable nodes driven by a feedback configuration. Another technique is using a switch for extra connections to the floating gate of the ISFET in a feedback loop [167] . The noise performance of the ISFETs is another non-ideality that can directly affect the sensor accuracy and resolution. The dominant low-frequency noise is 1/f noise. The measured noise characteristics in [226] showed that the Si/SiO 2 interface dominates the noise behavior and the interface between the gate insulator and the solution does not contribute to measurable noise. To reduce the noise, the ISFET's based on p-MOSFET can be used rather than n-MOSFET, because it is well established that the noise of p-MOSFET is lower by nearly two orders of magnitude [227] . However, n-type ISFETs have higher mobility and better drift performance. Another factor affecting the performance of the ISFET is temperature sensitivity. Circuit compensation techniques can be used for the alleviation of temperature variations. Wong et al. [184] proposed to use a differential configuration of an operational amplifier to match the ISFET sensor with a MOSFET and eliminate the temperature sensitivity. Equal electrical biases of the two devices are required to both devices have similar temperature characteristics, which might be difficult to be acquired by a differential pair comprising an ISFET and a MOSFET on the same chip [160] because of the differences in V t leading to different bias conditions. In another technique [228] , the ISFET temperature coefficient, which is dependent on the operating point, is cancelled out by choosing a proper bias condition and empirical determination of a thermal operating point. Simultaneous detection and use of the parameters of the measuring device that cause the temperature drift is an unusual approach in conventional electronics. Bergveld et al. [160] used the feedback system of Figure 24b and also inject a sinusoidal signal by employing a transformer connected between the bulk and the source of the ISFET to adjust a certain bias condition and produce sensitivity independent of β = µC ox (W/L) and internal source and drain resistances. Sohbati et al. [221] used a periodic gate reset to accurately set the DC operating point of the ISFET. Chin et al. [229] utilized a p-n diode as a temperature sensor whose negative temperature coefficient can cancel out the positive temperature coefficient of the ISFET by employing a summing circuit. Chung et al. [230] proposed another technique by using a threshold voltage extractor circuit to compensate for the ISFET thermal characteristic. People's health has been always endangered by infectious diseases such as universal viral outbreaks. Considering their significant impact on the fabric of society and the economy in general, the need for an expedited diagnosis for infectious agents (like viruses, bacteria, etc.) to control and limit its further spread into the population is inevitable in every country. We have learned expensive lessons from SARS-CoV-2 pandemic during which there was always a lack of systematic population testing methods by which, on one hand, the human interactions are minimized (a factor that extremely helps the government to curb the spread of disease very fast) and on the other hand, the infected people are treated at early stages at home and not when the situation is out of control and needs hospitalization. Therefore, surging toward the development of the extremely fast, reliable, portable, accurate and economical testing methods for fast detection of infectious agents' fingerprint in the human body is of imperative importance. In this review, however, a detailed demonstration of different FET sensors dedicated to biosensing by precise looking at the pros and cons of every single design has been provided. Furthermore, bio-recognition elements at the surface of these sensors (see part 3, Table 1 ) have been also reviewed and the corresponding structural and bioreceptor functionalization of them are discussed. We have tried to bring all elements of FET-based biosensors dedicated to specific bio-species detection, which enables one to assess the physical structure, bio-recognition surface and circuit design of new concepts. The study on the structural development of FET-based biosensors reveals that relying on the CMOS-based FET sensors enable the further standardization with well matured CMOS circuitry and mass production when scalability of the design is a concern. It has been discussed that integration of Chem/BioFETs with microfluidic chips is a stumbling block in front of successful integration of device with extremely small CMOS-based sensors. However, to address this inherent issue, there has been a tendency to develop extended gate structures for this purpose. Extended gate allows to have more sensing area, which can be integrated with microfluidic chip off the sensing area. Additionally, extended gate FETs would enable us to coat the sensor with novel nanomaterials such as graphene and carbon nanotubes to increase sensitivity and LoD with significantly improved response time. Another arrangement to take advantage of bigger sensing area and customized ion sensitive membrane is using floating membrane structure, which has the privilege of being based on the standard CMOS technology for making the gate off the oxide layer on the conductive channel. To have a better control over the sensitivity of the device, incorporation of double-gate and floating control-gate structures are recommended by researchers. Another spotted avenue for detecting infectious agents using FET structures was using novel nanomaterials like carbon-based and other 2D nanomaterials. Granting that moving toward CMOS technology encompasses various merits that have been discussed above, however, in terms of sensitivity, it appears that nanomaterials like graphene, MoS 2 , SiNW, and CNTs would contribute much more. For instance, recently for COVID-19, a detection graphene-based single-layer FET has been proven to reach fM detection of the virus antibody. The reason seems to not be laid under the structure of the device, yet the inherent conductive channel electron transporting characteristics take the responsibility that arise from the superior surface chemistry of novel nanomaterials when they are in interaction with solution ions and biomolecules. Even though these nanomaterials provide a much faster response time and an extraordinary lower LoD compared to SiO 2 /Si 3 N 4 -onsilicon (which is being used in CMOS-based ISFETs fabrication), there are many scaling issues in the fabrication and integration of these sensors that need much more research and future studies. The infection agent detection can be accomplished by label-free electrical detection of the agent itself, its specific antigens, nucleic acids fingerprint and also antibodies associated with that on FET-based biosensors. Using the multiplexed structure of sensors integrated with microfluidic channels could realize a combination of the detection scenarios mentioned above, which could offer a more robust and reliable design for detection of the targeted infectious agent. While there have been many success stories in published papers, the realworld realization of FET biosensors has a long way to be reliable. For instance, in human samples, there is a myriad of various proteins that in a non-specific attachment on the surface of FET sensor would create a false-positive response or true negatives that hamper the successful translational application of these sensors. Many efforts have been made to overcome the noises associated with unwanted attachment of bio-elements however they are done in very ideal laboratory conditions and very difficult to be used for real human samples. There are numerous hurdles in front of this technology if we want to replace the current gold standard like PCR with them for the detection of infectious agents. Many more studies are needed on the structural improvements, surface modification addressing the surface chemistry challenges and novel circuit designs that can reduce the noises associated with non-specific attachments and device inherent noises. Author Contributions: A.P. writing-original draft preparation, Sections 1, 2 and 5, and abstract; writing-review and editing Sections 3 and 4. D.S. writing-original draft preparation, Section 3; writing-review and editing Sections 1, 2, 4 and 5, and abstract. S.F. writing-original draft preparation, Section 4; writing-review and editing Sections 1-3 and Section 5, and abstract. E.G.-Z. supervision, the conceptualization in writing a comprehensive review paper, the overall organization of the paper; writing-review and editing Sections 1-5, and abstract. All authors have read and agreed to the published version of the manuscript. Funding: This research received no external funding. Rapid SARS-CoV-2 Detection Using Electrochemical Immunosensor Covid-19: What Have We Learnt about the New Variant in the UK? Evaluation of Antibody Response in Symptomatic and Asymptomatic COVID-19 Patients and Diagnostic Assessment of New IgM/IgG ELISA Kits Acute Clinical Syndromes and Suspicion of SARS-CoV-2 Infection: The Experience of a Single Romanian Center in the Early Pandemic Period COVID-19 Impact on Diagnostic Innovations: Emerging Trends and Implications. Diagnostics 2021 Quinacrine, an Antimalarial Drug with Strong Activity Inhibiting SARS-CoV-2 Viral Replication In Vitro. Viruses Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions Point-of-care testing based on smartphone: The current state-of-the-art A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors COVID-19 convalescent plasma: Now is the time for better science Fabrication of a miniature CMOS-based optical biosensor CMOS Based Capacitive Sensors for Life Science Applications: A Review Biosensors and their applications-A review Development of an ion-sensitive solid-state device for neurophysiological measurements Detection principles of biological and chemical FET sensors Automatic smartphone-based microfluidic biosensor system at the point of care Rapid detection of COVID-19 causative virus (SARS-CoV-2) in human nasopharyngeal swab specimens using field-effect transistor-based biosensor Nucleic acid amplification free biosensors for pathogen detection An integrated semiconductor device enabling non-optical genome sequencing Novel pH sensing semiconductor for point-of-care detection of HIV-1 viremia Rapid detection of E. coli bacteria using potassium-sensitive FETs in CMOS Sensitivity Potentiometric 65-nm CMOS ISFET Sensor for Rapid E. coli Screening Transient finite element analysis of electric double layer using Nernst-Planck-Poisson equations with a modified Stern layer Simulation of an electrical double layer model with a low dielectric layer between the electrode and the electrolyte Simulation of ISFET operation based on the site-binding model SPICE macromodel of silicon-on-insulator-field-effect-transistor-based biological sensors A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters Site-binding model of the electrical double layer at the oxide/water interface Molecular dynamics simulations of the electrical double layer on smectite surfaces contacting concentrated mixed electrolyte (NaCl-CaCl2) solutions Weak inversion ISFETs for ultra-low power biochemical sensing and real-time analysis Linear current-mode ISFET arrays Ion-specific hydration effects: Extending the Poisson-Boltzmann theory Parametrizing nonbonded interactions between silica and water from first principles Molecular dynamics simulations of the electric double layer capacitance of graphene electrodes in mono-valent aqueous electrolytes Selective ion sensing with high resolution large area graphene field effect transistor arrays Towards a multi-enzyme capacitive field-effect biosensor by comparative study of drop-coating and nano-spotting technique Label-Free Sensing of Biomolecules with Field-Effect Devices for Clinical Applications. Electroanalysis Two-dimensional nanomaterials for biosensing applications Graphene-based field-effect transistor biosensors for the rapid detection and analysis of viruses: A perspective in view of COVID-19 Recent advances in electrochemical biosensors based on fullerene-C60 nano-structured platforms High-performance field-effect transistor glucose biosensors based on bimetallic Ni/Cu metal-organic frameworks Metal-organic frameworks as active materials in electronic sensor devices Field-effect transistor biosensing: Devices and clinical applications Development of an aptamer-based field effect transistor biosensor for quantitative detection of Plasmodium falciparum glutamate dehydrogenase in serum samples Development, operation, and application of the ion-sensitive field-effect transistor as a tool for electrophysiology Characterization of human dental plaque formed on hydrogen-ionsensitive field-effect transistor electrodes A rapid method for detection of Clostridium thermocellum by field-effect transistor-based immunodetection Neuron adhesion on a silicon chip probed by an array of field-effect transistors Direct detection of the hybridization of synthetic homo-oligomer DNA sequences by field effect Long-term recording system based on field-effect transistor arrays for monitoring electrogenic cells in culture Mikrosensorische Systeme in der zellbiologischen Grundlagenforschung und der medizinischen Diagnostik Monitoring of cellular signalling and metabolism with modular sensor-technique: The PhysioControl-Microsystem (PCM ® ) Transistor records of excitable neurons from rat brain Electrical recordings from rat cardiac muscle cells using field-effect transistors Microelectronic sensor system for microphysiological application on living cells A 128 × 128 CMOS biosensor array for extracellular recording of neural activity Electrical imaging of neuronal activity by multi-transistor-array (MTA) recording at 7.8 µm resolution New insights into the nanometer-scaled cell-surface interspace by cell-sensor measurements Live monitoring of microenvironmental pH based on extracellular acidosis around cancer cells with cell-coupled gate ion-sensitive field-effect transistor Biologically coupled gate field-effect transistors meet in vitro diagnostics Electrochemical Field-Effect Transistor Utilization to Study the Coupling Success Rate of Photosynthetic Protein Complexes to Cytochrome c A large transistor-based sensor array chip for direct extracellular imaging FET-Based Chemical Sensor Systems Fabricated with Standard Technologies ISFET characteristics in CMOS and their application to weak inversion operation Dimension and shape effects on the ISFET performance Label-free, direct DNA detection by means of a standard CMOS electronic chip Mechanism of label-free DNA detection using the floating electrode on pentacene thin film transistor A CMOS, fully integrated sensor for electronic detection of DNA hybridization Surface functionalization of ion-sensitive floating-gate field-effect transistors with organic electronics Programmable ion-sensitive transistor interfaces. I. Electrochemical gating Programmable ion-sensitive transistor interfaces. III. Design considerations, signal generation, and sensitivity enhancement Depletion type floating gate p-channel MOS transistor for recording action potentials generated by cultured neurons EGFET-based sensors for bioanalytical applications: A review A potentiometric biosensor for rapid on-site disease diagnostics A Reliable BioFET Immunosensor for Detection of p53 Tumour Suppressor in Physiological-Like Environment Performance enhancement of capacitive-coupling dual-gate ion-sensitive field-effect transistor in ultra-thinbody Dual-gate thin-film transistors, integrated circuits and sensors Beyond the Nernst-limit with dual-gate ZnO ion-sensitive field-effect transistors High performance dual-gate ISFET with non-ideal effect reduction schemes in a SOI-CMOS bioelectrical SoC Graphene-Based Field Effect Transistor Biosensors for Breast Cancer Detection: A Review on Biosensing Strategies. Carbon Carbon nanotube based biosensors Silicon nanowire field-effect-transistor based biosensors: From sensitive to ultra-sensitive Two-dimensional MoS2: A promising building block for biosensors ZnO nanorods array based field-effect transistor biosensor for phosphate detection Biofunctionalized Zinc Oxide Field Effect Transistors for Selective Sensing of Riboflavin with Current Modulation A CMOS label-free DNA sensor using electrostatic induction of molecular charges Surface engineering for enhancement of sensitivity in an underlap-FET biosensor by control of wettability Signal-to-noise ratio enhancement of silicon nanowires biosensor with rolling circle amplification Detection of airborne viruses using electro-aerodynamic deposition and a field-effect transistor Detection of Avian Influenza Virus from Cloacal Swabs Using a Disposable Well Gate FET Sensor A field effect transistor modified with reduced graphene oxide for immunodetection of Ebola virus The field effect transistor DNA biosensor based on ITO nanowires in label-free hepatitis B virus detecting compatible with CMOS technology Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects Modularized Field-Effect Transistor Biosensors Limit of detection of field effect transistor biosensors: Effects of surface modification and size dependence How to make nanobiosensors: Surface modification and characterisation of nanomaterials for biosensing applications Current Trends of Nanobiosensors for Point-of-Care Diagnostics One-dimensional nanostructures based bio-detection Ultrasensitive Electrical Detection of Hemagglutinin for Point-of-Care Detection of Influenza Virus Based on a CMP-NANA Probe and Top-Down Processed Silicon Nanowire Field-Effect Transistors Nanowire transistor-based ultrasensitive virus detection with reversible surface functionalization Aptamer-Based Field-Effect Transistor for Detection of Avian Influenza Virus in Chicken Serum Ultra-low HIV-1 p24 detection limits with a bioelectronic sensor Graphene Nanogrids FET Immunosensor: Signal to Noise Ratio Enhancement Micropatterned reduced graphene oxide based field-effect transistor for real-time virus detection Detection of Rota Virus with the Help of Nanomaterial Based Field Effect Transistor (BIO-FET) Reduced graphene oxide-based field effect transistors for the detection of E7 protein of human papillomavirus in saliva Field-Effect Transistor Biosensor for Rapid Detection of Ebola Antigen Attomolar detection of virus by liquid coplanar-gate graphene transistor on plastic High-Sensitive and Selective Detection of Human-Infectious Influenza Virus Using Biomimetic Graphene Field-Effect Transistor Lab-on-a-graphene-FET detection of key molecular events underpinning influenza virus infection and effect of antiviral drugs Glycan-immobilized dual-channel field effect transistor biosensor for the rapid identification of pandemic influenza viral particles Zika virus detection using antibody-immobilized disposable cover glass and AlGaN/GaN high electron mobility transistors Quantitative and rapid Plasmodium falciparum malaria diagnosis and artemisinin-resistance detection using a CMOS Lab-on-Chip platform Advances in Silicon Nanowire Biosensors: Synthesis Methods, Properties, and Applications Nanowire biosensors for label-free, real-time, ultrasensitive protein detection Preparation of Silicon Nanowire Field-effect Transistor for Chemical and Biosensing Applications Nanowire sensors for multiplexed detection of biomolecules Preparation, Modification, Characterization, and Biosensing Application of Nanoporous Gold Using Electrochemical Techniques Surface modification of silicon and gold-patterned silicon surfaces for improved biocompatibility and cell patterning selectivity Graphene Field Effect Transistors for Biomedical Applications: Current Status and Future Prospects. Diagnostics Graphene and its derivatives as biomedical materials: Future prospects and challenges. Interface Focus Chemistry of Graphene Derivatives: Synthesis, Applications, and Perspectives Graphene-Based Biosensors for Detection of Biomarkers Graphene-based biosensors Carbon nanomaterials: Controlled growth and field-effect transistor biosensors Multi-walled carbon nanotube films for the measurement of the alcoholic concentration Overview of Carbon Nanotubes for Biomedical Applications Carbon nanotubes: Properties, synthesis, purification, and medical applications Advances on Sensors Based on Carbon Nanotubes Non-Carbon 2D Materials-Based Field-Effect Transistor Biosensors: Recent Advances, Challenges, and Future Perspectives 2D transition metal dichalcogenides Two-Dimensional Transition Metal Dichalcogenides: Synthesis Layered transition-metal dichalcogenides (MoS2 and WS2) for sensing and biosensing 2D layered transition metal dichalcogenides (MoS2): Synthesis, applications and theoretical aspects Two-dimensional transition metal dichalcogenide nanomaterials for biosensing applications Ultrasensitive monolayer MoS2 field-effect transistor based DNA sensors for screening of down syndrome Membraneless reproducible MoS2 fieldeffect transistor biosensor for high sensitive and selective detection of FGF21 Molybdenum disulfide field-effect transistor biosensor for ultrasensitive detection of DNA by employing morpholino as probe Two-dimensional Layered MoS2 Biosensors Enable Highly Sensitive Detection of Biomolecules Fabrication and comparison of MoS2 and WSe2 field-effect transistor biosensors MoS(2) field-effect transistor for next-generation label-free biosensors High-stability pH sensing with a few-layer MoS2 field-effect transistor Conducting polymers: An emerging field of biosensors Application of conducting polymers to biosensors Conducting Polymers and Their Applications to Biosensors: Emphasizing on Foodborne Pathogen Detection Conducting polymer nanowires for chemiresistive and FET-based bio/chemical sensors Conducting Polymer Based Nanobiosensors High-Performance Conducting Polymer Nanotube-based Liquid-Ion Gated Field-Effect Transistor Aptasensor for Dopamine Exocytosis Silicon Nanowire Field-Effect Transistor as Biosensing Platforms for Post-Translational Modification Electrical detection of hepatitis C virus RNA on single wall carbon nanotube-field effect transistors Ion-sensitive field-effect transistors fabricated in a commercial CMOS technology The operation of an ISFET as an electronic device Wheatstone-Bridge readout interface for ISFET/REFET applications ISFET sensor coupled with CMOS read-out circuit microsystem High-resolution real-time ion-camera system using a CMOS-based chemical sensor array for proton imaging Fabrication of a two-dimensional pH image sensor using a charge transfer technique Realization of 1 million pixel charge transfer type ion image sensor with 12 µm pixel pitch An adaptive ISFET chemical imager chip A robust ISFET pH-measuring front-end for chemical reaction monitoring An auto-offset-removal circuit for chemical sensing based on the PG-ISFET An integrated ISFETs instrumentation system in standard CMOS technology A highly miniaturized low-power CMOS-based pH monitoring platform ISFET arrays in CMOS: A head-to-head comparison between voltage and current mode A composite ISFET readout circuit employing current feedback A thermally powered ISFET array for on-body pH measurement A 128 × 128 current-mode ultra-high frame rate ISFET array with in-pixel calibration for real-time ion imaging Live demonstration: A CMOS-based lab-on-chip array for combined magnetic manipulation and opto-chemical sensing A dual-mode large-arrayed CMOS ISFET sensor for accurate and highthroughput pH sensing in biomedical diagnosis A robust ISFET array with in-pixel quantisation and automatic offset calibration A TDC based ISFET readout for large-scale chemical sensing systems High gain ISFET based νMOS chemical inverter A 64 pixel ISFET-based biosensor for extracellular pH gradient monitoring An ISFET based sensing array with sensor offset compensation and pH sensitivity enhancement The development of scalable sensor arrays using standard CMOS technology Design of a single-chip pH sensor using a conventional 0.6 µm CMOS process A CMOS-integrated'ISFET-operational amplifier'chemical sensor employing differential sensing New ISFET sensor interface circuit for biomedical applications A sigma delta ISFET readout circuit for Lab-on-Chip applications A Low Power Sub-µW Chemical Gilbert Cell for ISFET Differential Reaction Monitoring Thirty years of ISFETOLOGY: What happened in the past 30 years and what may happen in the next 30 years An adaptive CMOS-based PG-ISFET for pH sensing An analytical technique for counteracting drift in ion-selective field effect transistors (ISFETs) ISFETs in CMOS and emergent trends in instrumentation: A review Performance and system-on-chip integration of an unmodified CMOS ISFET A system-on-chip digital pH meter for use in a wireless diagnostic capsule Methods and Apparatus for Measuring Analytes Using Large Scale FET Arrays. Google Patents GB2461127B 3-T ISFET front-end utilising parasitic device capacitance A highly sensitive ISFET using pH-to-current conversion for real-time DNA sequencing Chemical log-domain filter A biochemical translinear principle with weak inversion ISFETs The chemical current-conveyor: A new microchip biosensor A linear programmable-gate ISFET array operating in velocity saturation Ultra-low power precision ISFET readout using global current feedback 64 pH-ISFET averaging array employing global negative current feedback ISFET based Urea: Creatinine translinear sensor An ISFET based translinear sensor for DNA methylation detection Towards ISFET based DNA logic for rapid nucleic acid detection ISFET-based chemical switch ISFET-based chemical Schmitt trigger Minimal readout scheme for ISFET sensing arrays based on pulse width modulation Improved inverter-based read-out scheme for low-power ISFET sensing array A novel pH-to-time ISFET pixel architecture with offset compensation Fast food safety screening with CMOS high-sensitivity large-arrayed ISFET sensor The cation concentration response of polymer gate ISFET Characteristics of reference electrodes using a polymer gate ISFET Sensitization of dielectric surfaces by chemical grafting: Application to pH ISFETs and REFETs A simple REFET for pH detection in differential mode How electrical and chemical requirements for REFETs may coincide Differential read-out architecture for CMOS ISFET microsystems A novel voltage-clamped CMOS ISFET sensor interface REFET replication for ISFET-based SNP detection arrays A temperature insensitive continuous time ∆pH to digital converter Matching the transconductance characteristics of CMOS ISFET arrays by removing trapped charge ISFET threshold voltage programming in CMOS using hot-electron injection ISFET threshold voltage programming in CMOS using electron tunnelling CMOS-based programmable gate ISFET Low frequency noise and drift in ion sensitive field effect transistors 1/f noise in ion sensitive field effect transistors from subthreshold to saturation A pH-ISFET sensor with on-chip temperature sensing A novel pH sensitive ISFET with on chip temperature sensing using CMOS standard process New ISFET interface circuit design with temperature compensation A.P. acknowledges the support of the CMC microsystem and Mitacs for the internship award. D.S. acknowledges the support of the York University for Elia scholarship. The authors declare no conflict of interest