key: cord-0826040-pipukd1m authors: Gharaibeh, Abeer; Smith, Richard H.; Conway, Michael J. title: Reducing Spread of Infections with a Photocatalytic Reactor—Potential Applications in Control of Hospital Staphylococcus aureus and Clostridioides difficile Infections and Inactivation of RNA Viruses date: 2021-01-11 journal: Infect Dis Rep DOI: 10.3390/idr13010008 sha: a59aff5a7bc2ea76fce42a365175c4852323b9c4 doc_id: 826040 cord_uid: pipukd1m Contaminated surfaces and indoor environments are important sources of infectious spread within hospital and non-hospital facilities. Bacterial infections such as infections with Clostridioides (formerly Clostridium) difficile (C. difficile) and Staphylococcus aureus (S. aureus) and its antibiotic resistant strains continue to pose a significant risk to healthcare workers and patients. Additionally, the recent emergence of the coronavirus disease 2019 (COVID-19) pandemic, which is caused by the novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), highlights the need for safe and effective methods to decontaminate surfaces to control infection spread in hospitals and the community. To address these critical needs, we tested a photocatalytic reactor decontamination method to disinfect contaminated surfaces in a hospital and a laboratory setting. By placing the reactor in a test hospital room, growth of S. aureus and C. difficile were significantly reduced compared with a control room. Additionally, using a model enveloped positive-sense single-stranded RNA virus, dengue virus type 2 (DENV2), we showed that the use of the photocatalytic reactor reduces viral infectivity. Collectively, the results demonstrate the potential utility of photocatalytic reactors in reducing the spread of highly contagious bacterial and viral infections through contaminated surfaces and environments. The discovery and implementation of novel environmentally friendly technologies for infection control are critically needed [1] . The emerging trends in healthcare-associated infections (HAIs) and the community spread of highly transmissible diseases, such as the new coronavirus disease 2019 (COVID- 19) , necessitates the need for easy-to-use, safe, and economic technologies to prevent the spread of diseases among patients, hospital workers, and in the community [2] . Contaminated surfaces and environments are important sources for the transmission and spread of infections including those caused by Clostridioides difficile (C. difficile), methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), norovirus, and the emerging novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes COVID- 19 [1]. One-day surveys of 11,282 inpatients in 183 hospitals in the US found that 452 of them had one or more HAIs [3] . Pneumonia and surgical site infections were the most common, with each accounting for 21.8% of cases, followed by gastrointestinal infection which constituted 17.1% of cases. C. difficile was the most common causative organism, followed by Staphylococcus aureus Infect. Dis. Rep. 2021, 13 59 (S. aureus), and then Klebsiella pneumoniae, Klebsiella oxytoca, and Escherichia coli (E. coli) [3] . In addition to the health impact, HAIs cause an economic burden with an estimated annual medical cost in the US ranging from $28.4 to $33.8 billion [4] . Improved control and reduction of HAIs are perpetual concerns in hospitals and other healthcare settings, including non-hospital residential facilities such as nursing homes and correctional facilities [5] [6] [7] . Control of C. difficile infection is considered a major challenge in healthcare facilities due to the capability of C. difficile spores to survive on hard surfaces for up to 5 months and their resistance to traditional environmental cleaning [8] . A 10-year review performed on C. difficile patients in acute care hospitals in the US during 2005 to 2014 indicated that the incidence of C. difficile infection is increasing [9] . It is estimated that half a million C. difficile infection cases occur yearly in the US with more than 24% of the cases are in hospital settings [10] . Another study found that 82% of patients with community-associated C. difficile infection reported that they had a history of outpatient or inpatient healthcare exposure without an overnight stay [11] . S. aureus infection as the second most common overall cause of HAIs reported to the National Healthcare Safety Network (NHSN) has also been of a particular concern [12] . Despite the variation in the incidence rates of these infections and the diversity of the causative organisms, broad effective control methods are needed along with comprehensive tracking and monitoring systems that could assess the effectiveness of these interventions [5] . While there has been a significant progress in reducing the standardized infection ratio (SIR) of S. aureus, particularly of its resistant strain (MRSA) [5] , nosocomial infections continue to plague both medical and residential settings [7] . Additionally, despite employing current methods to control staphylococcal bacteremia [13] , serious adverse events among patients remain unsatisfactorily high. A recent review of epidemiological studies on the incidence of MRSA infections has indicated that there is no definitive evidence that the incidence of these infections is declining [5] . The emergence of antibiotic-resistant bacterial strains illustrates pathogens' persistence despite the use of powerful, highly specific chemical agents and disinfectants. Viruses are also considered an important source of HAIs. Patients, doctors, nurses, other staff, students, trainees, and visitors could be potential carriers [14] . Specifically, healthcare-acquired viral respiratory diseases are common among children [15] . Nosocomial virus respiratory infections are an underestimated cause of morbidity and mortality, although studies have showed that viruses are responsible for 20% of nosocomial pneumonia [16] . A retrospective study at a tertiary care hospital estimated an incidence of 5 cases/10,000 admissions and 44 cases/10,000 admissions in adult and pediatric patients, respectively [17] . Moreover, the recent emergence of the COVID-19 pandemic, which is caused by the novel coronavirus, SARS-CoV-2, poses a significant risk to healthcare workers in addition to traditional nosocomial infections. The rapid spread of SARS-CoV-2 led to a global outbreak that has been declared as a pandemic by the World Health Organization (WHO). SARS-CoV-2 virus is a member of the Coronaviridae family of viruses, which are enveloped positive-sense single-stranded RNA viruses [18] . SARS-CoV-2 was found to spread via aerosols, large droplets, or contact with infectious secretions. Although the transmission of SARS-CoV-2 in a healthcare setting has not been linked directly to contaminated surfaces, previous experience with other coronaviruses demonstrates that contaminated surfaces pose an important risk of infection transmission within healthcare environments and in the community [19] . The virus has been shown to survive for up to three hours in aerosols, up to four hours on copper, up to 24 h on cardboard, and up to two to three days on plastic and stainless steel surfaces [19] . Recently, a study showed that with initial viral loads that are equivalent to the highest titers excreted by infectious patients, the virus was isolated viable for up to 28 days at 20 • C from common surfaces such as glass and stainless steel [20] . Environmental contamination with aerosolized droplets containing this pathogen can serve as a reservoir for infection and must be controlled by effective disinfection protocols. Minimizing the degree of environmental contamination with highly effective decontamination measures would aid in the overall containment efforts of the COVID-19 pandemic. Several studies demonstrated that environmental cleaning and surface disinfection strategies reduce contamination and transmission of infections [21] . However, traditional disinfection methods such as chlorination could produce harmful byproducts that could cause toxic adverse events [22] . The most common side effects of using traditional disinfectants according to the Centers for Disease Control and Prevention (CDC) are eye irritation (55%), followed by neurologic manifestations such as headache and dizziness (32%), respiratory symptoms such as throat irritation and cough (30%), and skin irritation (24%) [23] . Water pathogens also pose a health problem and are considered a source for HAIs that are caused by Legionella and Mycobacterium species [24] . Disinfection byproducts resulting from water chlorination are found to be associated with health hazards and increased risk for bladder cancer [25] . There is also a trend toward positive association with small gestational age, intrauterine growth restriction, preterm delivery, and higher frequency of congenital anomalies [25, 26] . Due to the efforts of Medicare to encourage improvements in patient safety in hospitals and other healthcare facilities, these facilities have improved their screening and anti-microbial efforts, including microbial surveillance, testing for antimicrobial resistance [27] , and introduction of comprehensive programs aimed at reducing contamination and cross-transmission. Such efforts are further encouraged to employ multiple simultaneous cleaning measures [28] . The study done by the latter group used multiple detergents, disinfectants, and new technologies, such as ultraviolet disinfection. The results of the outcome questionnaires indicate an incremental benefit over other traditional approaches. Therefore, further studies that aim at identification and validation of alternative effective, safe, and environmentally friendly methods are needed. Several new disinfection technologies have recently emerged for infection control in hospitals and the community [22] . These technologies include new disinfectant liquids such as improved hydrogen peroxide liquids, electrolyzed water, and cold air atmospheric pressure plasma systems [22] . Additionally, self-disinfecting surfaces that are coated with metals, such as copper and silver with innate antimicrobial properties, have been used to prevent the growth of bacteria on surfaces in hospitals [22] . Most recently, photocatalytic disinfection strategies have been developed and showed potential applications that could solve significant health and environmental problems [29] . Photocatalytic technology commonly involves a titanium dioxide semiconductor, which is generally safe, chemically stable, economic, and allows repeated use without substantial loss of its catalytic ability [29] . The antimicrobial effects of photocatalysis are mainly mediated by the induction of air ionization, which produces free electrons and positive ions leading to the formation of the superoxide radical anion O −2 , which forms hydrates. These intermediate species, which are called "cluster ions," react rapidly with particulates and volatile organic species. The mechanism of their bactericidal activity is mediated by a combination of cell membrane damage and induction of oxidation of internal cellular components [29] . In this study we aimed to test the efficacy of photocatalytic reactors in reducing hospital rooms contamination with S. aureus and C. difficile strains. Moreover, we validated the use of the photocatalytic reactor to inactivate enveloped RNA viruses using dengue virus type 2 (DENV2) as an experimental model [30] . The antiviral efficacy of the photocatalytic reactor was determined based on reduced or complete loss of viral infectivity in a cell culture system following exposure of the viral samples to the photocatalytic reactor treatment. 2.1. Assessment of the Effect of the Photocatalytic Reactor on S. aureus and C. difficile Institutional review board (IRB) approval was not required for this study, which was performed in unoccupied patient rooms. Experiments that involved S. aureus were conducted at Pontiac General Hospital (Pontiac, MI, USA) and National Sanitation Foundation (NSF) International laboratories (Ann Arbor, MI, USA). S. aureus (ATCC, BAA-41, Manassas, VA, USA) was cultured from a freezer stock. A total of 100 µL freezer stock was transferred into 10 mL trypticase soy broth (TSB) and incubated for 18-24 h at 35 ± 1 • C. The bacterial culture was vortexed and allowed to settle for 15 min, then the upper two thirds of settled culture were removed. The culture was then centrifuged twice at 3500× g for 15 min and re-suspended in 10 mL of 0.1% peptone water. After that, the cell suspension was diluted in 0.1% peptone water to an organism density of approximately 7.5 × 10 5 colony forming unit (CFU)/mL. The cell density (CFU/mL) was calculated by plating serial dilutions onto Petrifilm Aerobic Count Plates followed by incubation for 18-24 h at 35 ± 1 • C. A stainless steel tray was rinsed with 95% ethanol and then rinsed with deionized water and air-dried. Stainless steel carriers were dipped in 95% ethanol using forceps, rinsed with deionized water, and air-dried. Carriers were then placed in the stainless steel tray, covered with aluminum foil, and autoclaved on dry waste cycle at 121 • C for 30 min. The sterile carriers were individually placed in sterile petri dishes and affixed to the bottom of each petri dish with a sterilized adhesive (Command Brand Damage Free Hanging Strips, Figure 1B ). Fourteen carriers were inoculated with 10 µL of the 7.5 × 10 5 CFU/mL cell suspension. A single droplet was applied without spreading. One additional sterility control carrier with only 10 µL sterile 0.1% peptone water was also prepared. All carriers were allowed to dry for 20-40 min under conditions of 20-25 • C and 40-45% humidity. Institutional review board (IRB) approval was not required for this study, which was performed in unoccupied patient rooms. Experiments that involved S. aureus were conducted at Pontiac General Hospital (Pontiac, MI, USA) and National Sanitation Foundation (NSF) International laboratories (Ann Arbor, MI, USA). S. aureus (ATCC, BAA-41, Manassas, VA, USA) was cultured from a freezer stock. A total of 100 µL freezer stock was transferred into 10 mL trypticase soy broth (TSB) and incubated for 18-24 h at 35 ± 1 °C. The bacterial culture was vortexed and allowed to settle for 15 min, then the upper two thirds of settled culture were removed. The culture was then centrifuged twice at 3500× g for 15 min and re-suspended in 10 mL of 0.1% peptone water. After that, the cell suspension was diluted in 0.1% peptone water to an organism density of approximately 7.5 × 10 5 colony forming unit (CFU)/mL. The cell density (CFU/mL) was calculated by plating serial dilutions onto Petrifilm Aerobic Count Plates followed by incubation for 18-24 h at 35 ± 1 °C. A stainless steel tray was rinsed with 95% ethanol and then rinsed with deionized water and air-dried. Stainless steel carriers were dipped in 95% ethanol using forceps, rinsed with deionized water, and air-dried. Carriers were then placed in the stainless steel tray, covered with aluminum foil, and autoclaved on dry waste cycle at 121 °C for 30 min. The sterile carriers were individually placed in sterile petri dishes and affixed to the bottom of each petri dish with a sterilized adhesive (Command Brand Damage Free Hanging Strips, Figure 1B ). Fourteen carriers were inoculated with 10 µL of the 7.5 × 10 5 CFU/mL cell suspension. A single droplet was applied without spreading. One additional sterility control carrier with only 10 µL sterile 0.1% peptone water was also prepared. All carriers were allowed to dry for 20-40 min under conditions of 20-25 °C and 40-45% humidity. Experiments that involved C. difficile were conducted at Insight Institute of Neurosurgery and Neuroscience (Flint, MI, USA) and the NSF International laboratories (Ann Arbor, MI, USA). C. difficile (ATCC, 43598, Manassas, VA, USA) spores were obtained from the NSF International laboratories; they were prepared based on the published Environmental Protection Agency (EPA) MB-28 protocol [31] . Spore suspension was serially diluted in phosphate-buffered saline (PBS) and plated in duplicate to the Brain Heart Infusion Agar with Horse Blood and Taurocholate agar plates (BHIY-HT) and incubated anaerobically for 120 ± 4 h at 36 ± 1 °C after which the CFU/mL values were calculated. Stainless steel carriers were sterilized prior to use by dipping them in 70 to 95% ethanol, rinsing them with deionized water, and then autoclaving them at 121 °C. Carriers were then aseptically transferred into sterile petri dishes. Eight carriers were inoculated by 10 Experiments that involved C. difficile were conducted at Insight Institute of Neurosurgery and Neuroscience (Flint, MI, USA) and the NSF International laboratories (Ann Arbor, MI, USA). C. difficile (ATCC, 43598, Manassas, VA, USA) spores were obtained from the NSF International laboratories; they were prepared based on the published Environmental Protection Agency (EPA) MB-28 protocol [31] . Spore suspension was serially diluted in phosphate-buffered saline (PBS) and plated in duplicate to the Brain Heart Infusion Agar with Horse Blood and Taurocholate agar plates (BHIY-HT) and incubated anaerobically for 120 ± 4 h at 36 ± 1 • C after which the CFU/mL values were calculated. Stainless steel carriers were sterilized prior to use by dipping them in 70 to 95% ethanol, rinsing them with deionized water, and then autoclaving them at 121 • C. Carriers were then aseptically transferred into sterile petri dishes. Eight carriers were inoculated by 10 µL of inoculum suspension (3.3 × 10 5 CFU/mL) each and were then air-dried in a biosafety cabinet for one hour. The samples were then aseptically transferred into sterile conical tubes and transported under cold conditions to the testing rooms. Two additional sterility control carriers with only 10 µL sterile 0.1% peptone water were prepared. The stainless steel carriers containing S. aureus (ATCC, BAA-41) in the planktonic form were placed in two unoccupied rooms with similar air volume and airflow. One of these rooms served as a control, with no photocatalytic treatment. Eleven carriers were placed in the testing room and three were placed in the control room. Each room contained one attached bathroom with the door that remained closed during testing. Each room contained one large window which remained closed during testing with the blinds left open and lights remained off during testing. Doors remained closed throughout the period of testing. One photocatalytic reactor (Puradigm, Las Vegas, NV, USA) was placed in the testing room for 24 h prior to the samples and then maintained for 24 h during the testing ( Figure 1A and Supplementary 1). The stainless steel coupons inoculated with S. aureus were placed at various locations all over the test and control rooms, with focus on high-touch areas, including the patient bed, vanity, bedside table, windowsill, footboard, room door handle, television remote control, and light switches (Supplementary 1). All coupons were collected after 24 h and returned to the laboratory for processing. Each one was placed into a 50 mL centrifuge tube containing 30 mL of TSB and vortexed for 15 s. Then, 10 −1 dilutions of each sample were plated in duplicate onto Petrifilm Aerobic Count Plates and incubated for 18-24 h at 35 ± 1 • C, after which CFU/mL values for each sample were calculated. The stainless steel carriers containing C. difficile spores were placed in two unoccupied rooms with similar air volume and airflow. One of these rooms served as a control and one as a treatment room. A test chamber was constructed in each of the testing and control rooms by wrapping a plastic sheeting around a table and sealing the seams with duct tape (Supplementary 1). The photocatalytic reactor (Puradigm, Las Vegas, NV, USA) was placed in the testing chamber for 24 h prior to the samples and then maintained for 48 h for the duration of the treatment. Five stainless steel carriers were placed vertically in the secured chamber and exposed to the treatment for 48 h, while three coupons were placed in the control room with no exposure to treatment. Longer duration of treatment (48 h) was considered due to the known resistance of C. difficile spores compared to MRSA [32] . Each carrier was then aseptically placed into 30 mL PBS containing 0.1% Tween 80 (PBS-T) in a 50 mL conical tube. Each tube was vortexed for 30 s and the eluent was serially diluted in PBS, spread in duplicate onto BHIY-HT, and incubated anaerobically for 120 ± 4 h at 36 ± 1 • C, after which CFU/mL values for each sample were calculated. Experiments that included viruses were conducted at Central Michigan University. DENV2 strain New Guinea was obtained from the Connecticut Agricultural Experiment Station. The virus was passaged in C6/36 cells and the stocks were generated 8 days post-infection by harvesting cell-free supernatants. The cells were maintained in DMEM containing 10% fetal bovine serum, tryptose phosphate, and antibiotics at 30 • C. DENV2 was grown to approximately 2 × 10 3 focus forming units (FFU) per mL. FFU assays were performed using Aag2 cells. Each of these reagents were provided by Erol Fikrig at Yale University School of Medicine. Both C6/36 and Aag2 cells were maintained in high-glucose DMEM (Gibco, Waltham, MA, USA) with 10% fetal bovine serum (FBS), 5% penicillin-streptomycin (ThermoFisher, Waltham, MA, USA), and 5% tryptose phosphate (ThermoFisher, Waltham, MA, USA) at 28 • C with 5% CO 2 . Approximately 30 FFU of DENV2 were added to triplicate wells of two tissue culturetreated plastic 96-well plates. The first plate was placed inside of a biosafety cabinet along with the photocatalytic reactor (Puradigm, Las Vegas, NV, USA). The photocatalytic reactor was activated while the biosafety cabinet sash was closed. The second plate was placed in the second room at least 20 feet away from the closed biosafety cabinet. Six hours post-treatment, the triplicate DENV2 samples were transferred to monolayers of Aag2 cells and incubated for one hour. Unbound virus was removed and the cells were maintained in fresh media for 3 days. The cells were then fixed with 4% paraformaldehyde (Sigma, St. Louis, MO, USA), permeabilized with 0.1% Triton X (Sigma, St. Louis, MO, USA), and then stained with anti-dengue virus antibody 3H5.1 (MilliporeSigma, Burlington, MA, USA), followed by treatment with an anti-mouse IgG-HRP secondary antibody (Abcam, Cambridge, UK) and addition of a peroxidase substrate (Vector Laboratories, Burlingame, CA, USA). The number of foci was counted manually using an Evos XL Core Cell Imaging System. Approximately 150 FFU of DENV2 were added to triplicate wells of five tissue culturetreated plastic 96-well plates. Four plates were opened and placed inside of a biosafety cabinet. The biosafety cabinet was powered off while the sash was left open. The photocatalytic reactor (Puradigm, Las Vegas, NV, USA) was placed on the ground in the lab, outside the biosafety cabinet, activated, and set to the second power setting. The room dimensions were 14 feet in length, 9 feet in height, and 10 feet in width. The fifth plate was opened and placed in a drawer in the second room at least 20 feet away from the biosafety cabinet. Plates in the biosafety cabinet were removed and placed along with the fifth plate for 6, 12, 18, and 24 h post-treatment. Triplicate DENV2 samples were resuspended in 100 µL cell culture media by pipetting up and down ten times, and then the virus was transferred to monolayers of Aag2 cells and incubated for one hour. Unbound virus was removed and the cells were maintained in fresh media for 3 days. The cells were then fixed with 4% paraformaldehyde (Sigma, St. Louis, MO, USA), permeabilized with 0.1% Triton X (Sigma, St. Louis, MO, USA), and then stained with anti-DENV2 antibody 3H5.1 (Millipore Sigma, Burlington, MA, USA), followed by treatment with an anti-mouse IgG-HRP secondary antibody (Abcam, Cambridge, UK) and addition of a peroxidase substrate (Vector Laboratories, Burlingame, CA, USA). The number of foci was counted manually using an Evos XL Core Cell Imaging System. Statistical analyses were performed using SPSS v25 (IBM, Armonk, NY, USA). Log number of S. aureus and C. difficile per exposed and unexposed samples (log CFU/carrier) were calculated. Percentages of reduction and log reductions of S. aureus and C. difficile (CFU/mL) after 24 h-or 48 h-exposure, respectively, were calculated. Descriptive statistics and two-sample t-test were used to compare the log CFU/carrier values of the treated and untreated samples after the duration of treatment in each experiment. For the virus experiment, descriptive statistics and multiple two-sample t-tests were used to compare the average FFU/mL values between the treated and control samples in each group. Percentages of reduction in infectivity (FFU/mL) after 6, 12, 18, and 24 h of treatment compared to the control were calculated. The alpha level was set at p < 0.05 for all analyses. To assess the efficacy of photocatalysis in reducing the growth of S. aureus in a hospital room, we used stainless steel carriers inoculated with 10 µL of the 7.5 × 10 5 CFU/mL of S. aureus and placed the samples at multiple locations in an unoccupied patient room (Figure 1 and Supplementary 1) . A hospital room with no exposure to the photocatalytic reactor was used as a control. Based on the calculated CFU of each sample (Figure 2A in unoccupied rooms. We used stainless steel carriers containing C. difficile spores and placed them inside test chambers in treatment and control rooms. Our results ( Figure 2C ,D and Supplementary 1) showed that the growth of C. difficile was significantly reduced in the treated samples compared to the control samples. The average percentage of reduction in growth was 99.2% (95% CI: 98.1 to 99.7%) after 48 h of treatment compared to the control. Two sample t-test analysis showed that the log CFU of C. difficile in the testing room (M = 0.71, SD = 0.51) was significantly smaller (p = 0.0003) compared to the controls (M = 2.8, SD = 0.28), with the 2.1 (95% CI: 1.71 to 2.58) average log reduction in growth in the testing room. The efficacy of photocatalysis in reducing the growth of C. difficile was also assessed in unoccupied rooms. We used stainless steel carriers containing C. difficile spores and placed them inside test chambers in treatment and control rooms. Our results ( Figure 2C ,D and Supplementary 1) showed that the growth of C. difficile was significantly reduced in the treated samples compared to the control samples. The average percentage of reduction in growth was 99.2% (95% CI: 98.1 to 99.7%) after 48 h of treatment compared to the control. Two sample t-test analysis showed that the log CFU of C. difficile in the testing room (M = 0.71, SD = 0.51) was significantly smaller (p = 0.0003) compared to the controls (M = 2.8, SD = 0.28), with the 2.1 (95% CI: 1.71 to 2.58) average log reduction in growth in the testing room. To assess the effects of the photocatalytic reactor on enveloped RNA viruses, we used DENV2 as an experimental model. There was an average of 83.5% (95% CI: 74.5 to 92.5%) decrease in infectivity after 6 h of treatment inside of the biosafety cabinet (Figure 3 and Supplementary 2). Two-sample t-test analysis showed that exposure of DENV2 to the photocatalytic reactor inside a biosafety cabinet for 6 h significantly reduced the number of FFU/mL compared to the control (p = 0.0004). The second set-up experiment, while having the photocatalytic reactor inside the room but outside the biosafety cabinet, showed that the average percentage of reduction was 31.7% (95% CI: 17 to 46.4%), 76.5% (95% CI: 63.8 to 89.2%), 91.2% (95%: CI 84.4 to 98%) and 98.5% (95% CI: 95.7 to 100%) after 6, 12, 18, and 24 h, respectively (Figure 4 and Supplementary 2). Multiple two-sample t-test analyses revealed that there were significant decreases in DENV2 infectivity in the treated samples (p = 0.0326, p = 0.001, p = 0.0002, and p = 0.0001 after 6, 12, 18, and 24 h, respectively) compared to the control (Figure 4 and Supplementary 2). C. difficile spores were placed in the testing room and three samples were placed in the control room. The graph represents the average log CFU/carrier values of the samples in the testing room compared to the control. Two sample t-test analysis data showed that there was a significant reduction in the log CFU of C. difficile in the testing room after 48 h of treatment (M = 0.7, SD = 0.51) compared to the control (M = 2.8, SD = 0.28 * p < 0.001). (D) A representative graph for the percentage of C. difficile reduction in the testing room compared to the control. There was an average 99.2% (95% CI: 98.1 to 99.7%) reduction in bacterial growth in the samples that were placed in the testing room compared to the control. To assess the effects of the photocatalytic reactor on enveloped RNA viruses, we used DENV2 as an experimental model. There was an average of 83.5% (95% CI: 74.5 to 92.5%) decrease in infectivity after 6 h of treatment inside of the biosafety cabinet (Figure 3 and Supplementary 2). Two-sample t-test analysis showed that exposure of DENV2 to the photocatalytic reactor inside a biosafety cabinet for 6 h significantly reduced the number of FFU/mL compared to the control (p = 0.0004). The second set-up experiment, while having the photocatalytic reactor inside the room but outside the biosafety cabinet, showed that the average percentage of reduction was 31.7% (95% CI: 17 to 46.4%), 76.5% (95% CI: 63.8 to 89.2%), 91.2% (95%: CI 84.4 to 98%) and 98.5% (95% CI: 95.7 to 100%) after 6, 12, 18, and 24 h, respectively (Figure 4 and Supplementary 2). Multiple two-sample t-test analyses revealed that there were significant decreases in DENV2 infectivity in the treated samples (p = 0.0326, p = 0.001, p = 0.0002, and p = 0.0001 after 6, 12, 18, and 24 h, respectively) compared to the control (Figure 4 and Supplementary 2). (B) A representative graph for the average percentage of reduction in FFU/mL values after six hours of exposure to the photocatalytic treatment which was 83.5% (95% CI: 74.5 to 92.5%). (C) Representative digital images of DENV2-positive foci from the control and treated samples were taken at 20× magnification using an Evos Core inverted microscope. Contaminated surfaces and environments are an important source of HAIs and infection spread within hospital and non-hospital facilities [22] . Multidrug-resistant bacteria have both economical and health impacts, and it is estimated that by 2050, they will be held responsible for 10 million deaths [33, 34] . Surfaces that are not properly cleaned or disinfected facilitate the transmission of communicable diseases among patients, their families, and the healthcare workers [1]. Despite the use of more effective cleaning and disinfection strategies, the abundance of infective agents is on the rise in many hospital areas including patients' rooms and frequently touched surfaces [27] . Surface decontamination is a basic approach to reduce the spread of infections. With the significant burden of C. difficile and MRSA infections within hospitals and the emergence of highly transmissible pandemic diseases such as COVID-19, there is a pressing need for efficient surface cleaning and decontamination technologies [1, 35] . Our results demonstrated a significant reduction in C. difficile and S. aureus growth in the hospital rooms that were treated with a photocatalytic reactor compared with the control room. Moreover, we tested the efficacy of the photocatalytic reactor in suppressing the infectivity of RNA viruses using DENV2 as the experimental model. Our results demonstrated that the exposure of viruses to the photocatalytic reactor treatment led to a statistically significant and dose-dependent decrease in viral infectivity. The photocatalytic reactors involve a photocatalytic oxidation technology that has been shown to reduce the growth of the microbial organisms on contaminated surfaces and in the surrounding environment [29] . Previous research showed that the antimicrobial mechanism of photocatalytic oxidation depends on the generation of "cluster ions" Contaminated surfaces and environments are an important source of HAIs and infection spread within hospital and non-hospital facilities [22] . Multidrug-resistant bacteria have both economical and health impacts, and it is estimated that by 2050, they will be held responsible for 10 million deaths [33, 34] . Surfaces that are not properly cleaned or disinfected facilitate the transmission of communicable diseases among patients, their families, and the healthcare workers [1]. Despite the use of more effective cleaning and disinfection strategies, the abundance of infective agents is on the rise in many hospital areas including patients' rooms and frequently touched surfaces [27] . Surface decontamination is a basic approach to reduce the spread of infections. With the significant burden of C. difficile and MRSA infections within hospitals and the emergence of highly transmissible pandemic diseases such as COVID-19, there is a pressing need for efficient surface cleaning and decontamination technologies [1, 35] . Our results demonstrated a significant reduction in C. difficile and S. aureus growth in the hospital rooms that were treated with a photocatalytic reactor compared with the control room. Moreover, we tested the efficacy of the photocatalytic reactor in suppressing the infectivity of RNA viruses using DENV2 as the experimental model. Our results demonstrated that the exposure of viruses to the photocatalytic reactor treatment led to a statistically significant and dose-dependent decrease in viral infectivity. The photocatalytic reactors involve a photocatalytic oxidation technology that has been shown to reduce the growth of the microbial organisms on contaminated surfaces and in the surrounding environment [29] . Previous research showed that the antimicrobial mechanism of photocatalytic oxidation depends on the generation of "cluster ions" within the environment. The primary positive ions dinitrogen (N 2 ), dioxygen (O 2 ), nitrogen (N), and oxygen (O) are very rapidly converted, within microseconds, to protonated hydrates, H + (H 2 O), while free electrons quickly attach to oxygen to form the superoxide radical anion O −2 , which also can form hydrates [36] . Ionization of oxygen and formation of reactive oxygen species (ROS) is involved in many applications of air ionization. Previous study showed that superoxide ion clusters that are formed in the air could react rapidly with airborne particulates. ROS react with volatile organic compounds (VOCs) and yield particulates that are more easily removed or tolerated [37] . Several new ultraviolet-based technologies have been reported to effectively control and eliminate airborne contaminants. These include controlling aerosol contaminants and airborne fungal spores and bacteria [38] . Ultraviolet light is used as an internal light source in photocatalytic reactors. Photocatalysis is a branch of chemistry which deals with chemical reactions taking place in the presence of light and a photocatalyst. A photocatalyst is a semiconductor with the electrical conductivity value that falls between that of a conductor and an insulator [39] . In many photocatalytic systems, the semiconductor is composed of titanium dioxide that might be combined with other elements [40] . This combination can produce an ionized cloud of bactericidal and antiviral molecules. When ultraviolet energy strikes the titanium dioxide, it triggers a catalytic reaction that may produce the desired cloud of bactericidal molecules in the air [40] . These molecules, upon contact with any bacteria, mold, or viruses, may cause a robust antimicrobial effect. Semiconductor photocatalysis, with a focus on titanium dioxide as a durable photocatalyst, has been used for potable water treatment, air purification, destruction of microorganisms, inactivation of cancer cells, odor control, photo splitting of water to produce hydrogen fuel, fixation of nitrogen, and clean-up of oil spills [38] . Plethora of evidence showed that photocatalysis can kill and inactivate a lot of microorganisms from different kingdoms. The efficacy of photocatalytic disinfection using titanium dioxide was previously studied on gram-negative bacteria including mainly E. coli, Acinetobacter, Legionella pneumophila, and Pseudomonas aeruginosa [41] [42] [43] [44] [45] [46] . Although gram-positive bacteria were shown to be more resistant than the gram-negative ones [41, 47, 48] , studies on MRSA, S. aureus, and Listeria monocytogenes showed that they are vulnerable to killing by photocatalysis [49] [50] [51] . Dunlop and colleagues also showed that photocatalytic coated surfaces reduce viability of C. difficile spores and cells within biofilms [32] . Interestingly, studies on viruses including SARS, influenza A/H1N1, norovirus, influenza A/H 3 N 2 also showed that photocatalysis has effects on them [52] [53] [54] [55] . Additionally, it was found that photocatalysis inactivates microbial toxins [56] [57] [58] . The mechanism by which photocatalysis kills microbial cells was mainly studied in E. coli [59] . An early suggested mechanism was that oxidation process decreases coenzyme A levels in cells which lead to metabolic reduction [60, 61] . Recent studies have shown that the ROS generated by photocatalysis induce lipid peroxidation of bacterial cell membranes causing increased membrane permeability and cell membrane damage [59] . A strong positive association between potassium leakage, which is caused by increased cell permeability, and bacterial inactivation suggested that depletion of potassium has a main effect on bacterial cells [49] . Moreover, the permeability of cells has been found to be too extensive, allowing even large macromolecules such as beta-D-galactosidase molecules [62] . Additionally, direct effect on intracellular compartments were also noted with observed reduction in enzymatic activity [62] . ROS also trigger oxidative stress within the microorganism causing diminished ability to produce adenosine triphosphate (ATP) [59] . The effect of photocatalysis on the cell wall and membrane was also studied using high resolution image techniques. Kangwansupamonkon and colleagues performed scanning electron microscope (SEM) studies on S. aureus, MRSA, E. coli, and Micrococcus luteus and observed morphological alterations in the cell wall and outer membrane [63] . Cell membrane bubbles and vesicle-containing material detached from the cells were seen also in P. aerugi-nosa examined by SEM and transmission electron microscopy (TEM) [64, 65] . Interestingly, the morphological changes that were seen with photocatalytic treatment were similar to those of antibiotic aminoglycosides [65] . Imaging techniques also help in understanding the sequence of events. Utilizing atomic force microscopy, Sunada and colleagues showed that the outer cell membrane was disrupted first, followed by the cytoplasmic membrane, ultimately leading to cell death [66] . Similar membrane damage was also observed in fungi and members of Kingdom Protozoa, such as Oedogonium species, Chroococcus species, Candida albicans, Giardia lamblia, and Tetrahymena pyriformis [29] . A study on viruses also showed that the photocatalytic treatment of influenza virus A/H1N1 resulted in significant structural damage that involved damage to the H and N projections [53] . Our results showed that the photocatalytic reactor treatment reduced growth of S. aureus and C. difficile, and decreased the infectivity of DENV2. This study was limited to only one bacterial strain of each of C. difficile and S. aureus in addition to an RNA virus (DENV2) as a proof of concept. Our data demonstrate that there is a potential efficacy of using photocatalytic reactors to clean surfaces and environments within hospitals, laboratories, and non-hospital facilities which may reduce spread of infections. Future studies should aim at testing multiple pathogens with focusing on mechanisms and safety and modifying variable factors to optimize the efficacy of photocatalytic treatment. This will further validate the photocatalytic reactor treatment as a method to reduce the spread of bacterial and viral infections and improve containment of pandemics such as COVID-19 among hospital workers, patients, and the community. Controlling Hospital-Acquired Infection: Focus on the Role of the Environment and New Technologies for Decontamination Accuracy of Emergency Department Clinical Findings for Diagnosis of Coronavirus Disease Multistate Point-Prevalence Survey of Health Care-Associated Infections The Direct Medical Costs of Healthcare-Associated Infections in U.S. Hospitals and the Benefits of Prevention The incidence of MRSA infections in the United States: Is a more comprehensive tracking system needed? Identification and Characterization of Failures in Infectious Agent Transmission Precaution Practices in Hospitals: A Qualitative Study A systematic review of transmission dynamic studies of methicillin-resistant Staphylococcus aureus in non-hospital residential facilities Colitis Due to Clostridium difficile Toxins: Underdiagnosed, Highly Virulent, and Nosocomial Ten-Year Review of Clostridium difficile Infection in Acute Care Hospitals in the USA Burden of Clostridium difficile Infection in the United States National Healthcare Safety Network Team and Participating National Healthcare Safety Network Facilities. Antimicrobial-Resistant Pathogens Associated with Healthcare-Associated Infections: Annual Summary of Data Reported to the National Healthcare Safety Network at the Centers for Disease Control and Prevention Effect of Algorithm-Based Therapy vs Usual Care on Clinical Success and Serious Adverse Events in Patients with Staphylococcal Bacteremia: A Randomized Clinical Trial Nosocomial Spread of Viral Disease Health Care-Acquired Viral Respiratory Diseases Nosocomial Viral Infections: I. Epidemiology and Significance Hospital-Acquired Respiratory Viral Infections: Incidence, Morbidity, and Mortality in Pediatric and Adult Patients Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2): An Update Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 SARS-CoV-2 detection, viral load and infectivity over the course of an infection Does improving surface cleaning and disinfection reduce health care-associated infections? Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals Acute antimicrobial pesticide-related illnesses among workers in health-care facilities-California Hospital Water and Opportunities for Infection Prevention Health impacts of long-term exposure to disinfection by-products in drinking water in Europe: HIWATE Trihalomethanes, chlorite, chlorate in drinking water and risk of congenital anomalies: A population-based case-control study in Northern Italy Examining the Association between Surface Bioburden and Frequently Touched Sites in Intensive Care Improving Hospital Environmental Hygiene with the Use of a Targeted Multi-Modal Bundle Strategy Photocatalytic disinfection using titanium dioxide: Spectrum and mechanism of antimicrobial activity Viral Innate Immune Evasion and the Pathogenesis of Emerging RNA Virus Infections. Viruses Procedure for the Production and Storage or Spores of Clostridium difficile for Use in the Efficacy Evaluation of Antimicrobial Agents Inactivation of Clinically Relevant Pathogens by Photocatalytic Coatings Impact of multi-drug resistant bacteria on economic and clinical outcomes of healthcare-associated infections in adults: Systematic review and meta-analysis Tackling Drug-Resistant Infections Globally: Final Report and Recommendations; Review on Antimicrobial Resistance Coronaviruses post-SARS: Update on replication and pathogenesis On the ionization of air for removal of noxious effluvia. In Air ionization of indoor environments for control of volatile and particulate contaminants with nonthermal plasmas generated by dielectric-barrier discharge On the qualities of the air as affected by radiant energies (photocatalytic ionization processes for remediation of indoor environments) Advanced Oxidation Processes for Waste Water Treatment Enhanced Photo-Catalytic Cells Photocatalytic inactivation of Escherichia coli and Lactobacillus helveticus by ZnO and TiO2 activated with ultraviolet light The photocatalytic removal of bacterial pollutants from drinking water Bactericidal effect of an energy storage TiO2-WO3 photocatalyst in dark Abd El-Haleem, D. Reprint from Disinfection of bacterial suspensions by photocatalytic oxidation using TiO2 nanoparticles under ultraviolet illumination Ultraviolet Germicidal Irradiation and Titanium Dioxide Photocatalyst for Controlling Legionella pneumophila Photocatalytic sterilization of TiO2 films coated on Al fiber Photocatalytic Inactivation of Bioaerosols by TiO2 Coated Membrane Photocatalytic inactivation of Gram-positive and Gram-negative bacteria using fluorescent light Photocatalytic Degradation of Pathogenic Bacteria with AgI/TiO 2 under Visible Light Irradiation Efficacy of titanium dioxide photocatalyst for inhibition of bacterial colonization on percutaneous implants Bactericidal effect of TiO2 photocatalyst on selected food-borne pathogenic bacteria The inactivation effect of photocatalytic titanium apatite filter on SARS virus Inactivation Efficiency of TiO~2 on H1N1 Influenza Virus Degradation of norovirus in sewage treatment water by photocatalytic ultraviolet disinfection Inactivation and Mineralization of Aerosol Deposited Model Pathogenic Microorganisms over TiO 2 and Pt/TiO 2 UV and solar TiO2 photocatalysis of brevetoxins (PbTxs) Bactericidal and Detoxification Effects of TiO 2 Thin Film Photocatalysts Kinetic Modeling of TiO 2 -Catalyzed Photodegradation of Trace Levels of Microcystin-LR Bactericidal activity of photocatalytic TiO(2) reaction: Toward an understanding of its killing mechanism Continuous-sterilization system that uses photosemiconductor powders Photoelectrochemical sterilization of microbial cells by semiconductor powders Bactericidal mode of titanium dioxide photocatalysis Antibacterial effect of apatite-coated titanium dioxide for textiles applications Photoinduced bactericidal activity against Pseudomonas aeruginosa by TiO 2 based thin films TEM evidence of ultrastructural alteration on Pseudomonas aeruginosa by photocatalytic TiO2 thin films Studies on photokilling of bacteria on TiO2 thin film The authors would like to thank Yasser Heakal for editing parts of the manuscript. The authors declare no conflict of interest.