key: cord-0825614-wboh6dja authors: Rosadas, Carolina; Randell, Paul; Khan, Maryam; McClure, Myra O; Tedder, Richard S title: Testing for responses to the wrong SARS-CoV-2 antigen? date: 2020-08-28 journal: Lancet DOI: 10.1016/s0140-6736(20)31830-4 sha: 0651285910307cb8e6232eacc9b5f0884ae1d64e doc_id: 825614 cord_uid: wboh6dja nan Two commercial antibody tests (Abbott SARS-CoV-2 IgG, Abbott Diagnostics, Abbott Park, IL, USA; and Roche Elecsys Anti-SARS-CoV-2, Roche Diagnostics, Basel, Switzerland), both targeting antibodies to nucleo protein (anti-NP), constitute the corner stone of the UK Government's response to the COVID-19 pandemic. The test manufactured by Abbott, which is widely used in Europe and the USA, claims a specificity and sensitivity of greater than 99% at 14 days or more after symptoms started and has been validated by Public Health England. 1 We received 2204 serum samples from staff and patients previously screened for anti-NP on the Abbott platform as part of the routine diagnostic service by the UK National Health Service. These samples, principally selected in the Abbott binding ratio range of 0·25-2·5, were further tested using an inhouse double binding antigen ELISA (Imperial Hybrid DABA; Imperial College London, London, UK), which detects total antibodies to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) receptor binding domain (RBD). This assay has a specificity of 100% (95% CI 99·6-100), defined by testing 825 serum samples that predated the COVID-19 pandemic, and a sensitivity of 98·9% (96·8-99·8) when evaluating 276 serum samples from individuals with RT-PCR-confirmed SARS-CoV-2 infection. Among 511 samples with Abbott binding ratios of 0·25 to less than 1·4, 294 (58%) had detectable anti-RBD antibodies (ranging from 34% for binding ratios 0·25-0·5 to 94% for binding ratios 1·25-1·4; appendix). Discordant samples were classified into five groups based on their Imperial Hybrid DABA binding ratio. Eight serum samples from each group were randomly selected and assayed by a second in-house assay, an S1 G and M capture ELISA, to verify the anti-RBD findings. Anti-S1 antibodies were detected in 28 (88%) of 32 samples that were reactive for anti-RBD but unreactive for anti-NP. The four serum samples not confirmed by the S1 capture ELISA had low binding ratios in the Imperial Hybrid DABA, the S1 nonreactivity being consistent with the lower sensitivity of the capture assay compared with the Imperial Hybrid DABA. Eight serum samples selected at random from 76 reactive only in the Abbott assay were unreactive for antibody to S1. There are two possible explanations for these findings: either the Abbott assay results constitute falsepositive reactions; 2 or these patients did not mount a detectable humoral response to S1, as can happen with asymptomatic or mild infection. 3, 4 The UK Government's decision to facilitate use of Abbott' assay was intemperate. Anti-NP is insensi tive in the field: why was this insensitivity not recognised by those who validated its use in the UK? Moreover, Abbott's assay does not indicate accurately the presence of neutralising and potentially protective antibodies in the convalescent individual. Those who might still deign to use this assay as the sole marker of past infection would be wise to consider confirmatory algo rithms to better inform individuals investigated for anti-NP. RST Evaluation of the Abbott SARS-CoV-2 IgG for the detection of anti-SARS-CoV-2 antibodies Whole nucleocapsid protein of SARS-CoV-2 may cause false positive results in serological assays Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections Differences in antibody kinetics and functionality between severe and mild SARS-CoV-2 infections