key: cord-0823292-y9yeet31 authors: Tharak, Athmakuri; Kopperi, Harishankar; Hemalatha, Manupati; Kiran, Uday; C. G., Gokulan; Moharir, Shivranjani; Mishra, Rakesh K.; Mohan, S. Venkata title: Longitudinal and Long-Term Wastewater Surveillance for COVID-19: Infection Dynamics and Zoning of Urban Community date: 2022-02-25 journal: Int J Environ Res Public Health DOI: 10.3390/ijerph19052697 sha: 48604c31c0d3ac3a34d59a03bb3371270ba3be69 doc_id: 823292 cord_uid: y9yeet31 Wastewater-based epidemiology (WBE) is emerging as a potential approach to study the infection dynamics of SARS-CoV-2 at a community level. Periodic sewage surveillance can act as an indicative tool to predict the early surge of pandemic within the community and understand the dynamics of infection and, thereby, facilitates for proper healthcare management. In this study, we performed a long-term epidemiological surveillance to assess the SARS-CoV-2 spread in domestic sewage over one year (July 2020 to August 2021) by adopting longitudinal sampling to represent a selected community (~2.5 lakhs population). Results indicated temporal dynamics in the viral load. A consistent amount of viral load was observed during the months from July 2020 to November 2020, suggesting a higher spread of the viral infection among the community, followed by a decrease in the subsequent two months (December 2020 and January 2021). A marginal increase was observed during February 2021, hinting at the onset of the second wave (from March 2021) that reached it speak in April 2021. Dynamics of the community infection rates were calculated based on the viral gene copies to assess the severity of COVID-19 spread. With the ability to predict the infection spread, longitudinal WBE studies also offer the prospect of zoning specific areas based on the infection rates. Zoning of the selected community based on the infection rates assists health management to plan and manage the infection in an effective way. WBE promotes clinical inspection with simultaneous disease detection and management, in addition to an advance warning signal to anticipate outbreaks, with respect to the slated community/zones, to tackle, prepare for and manage the pandemic. The diagnostic aids, equipment and medical facilities have phenomenally improved since the emergence of the SARS-CoV-2 pandemic, in addition to the surveillance of SARS-CoV-2 using clinical data. However, employing swab samples obtained from person to person during critical periods of the pandemic is a challenge to understand spread among communities [1] [2] [3] . Wastewater based epidemiological study (WBE) is being conceived as one of the viable protocols that can infer the dynamics and infection rates of SARS-CoV-2 and its state of severity among the community [4] [5] [6] [7] . WBE data will assist in detecting viruses in a community prior to clinical recognition, allowing preventive measure and precautions to be dispersed among the community to resist the outbreak [8] [9] [10] [11] . The design Int. J. Environ. Res. Public Health 2022, 19 , 2697 2 of 20 of the sampling protocol is a crucial factor to detect the COVID-19 genetic material in the wastewater, since SARS-CoV-2 able to infect the gastrointestinal tract (GI) in addition to the bronchial inflammation [12] [13] [14] [15] [16] [17] [18] . A load of viral material temporally alters sewage based on the time of defecation frequencies and sampling [19, 20] . Diverse viral load shedding from the affected community, convergence of household wastewater and industrial effluents and time of sampling could affect the detection of the viral genome in the sewage; however, WBE provides a range of information to predict the dynamics of infection with the design of a sampling protocol [7, [13] [14] [15] [21] [22] [23] [24] [25] . The development of highly sensitive and specific RT-PCR tests to detect SARS-CoV-2 (the corona virus causing the COVID-19 pandemic) in sewage samples presents the potential to use wastewater sampling as a diagnostic test for SARS-CoV-2 in the community [21] [22] [23] [24] . Different independent SARS-CoV-2 WBE studies have followed various sewage sampling and processing methods to detect the SARS-CoV-2 RNA in sewage [7, [23] [24] [25] . The grab sampling method can be used in remote areas and even in poor sewage system conditions, which aids in improving surveillance [22] . These kinds of WBE methods will help to monitor surveillance in the area where proper hospitality infrastructure is lacking. A truly representative sample at the selected station and its load provide information about the spread and impact of the infection that helps to provide early warning signals [25] [26] [27] [28] . The current study made an attempt to investigate the persistence and dynamics of SARS-CoV-2 in wastewater by conducting longitudinal sampling over a period of one year ((July 2020 to August 2021), excluding the rainfall event months, i.e., August 2020 and September 2020) in a selected community representing~2.5 lakhs of population. A total of eight sampling points were selected in the Tarnaka and Nacharam areas of Hyderabad covering both lateral and main drains. Both weekly (during peak infection period) and monthly monitoring was conducted to predict the dynamics of the virus overtime. The study area represents a community with~2.5 lakhs population covering Tarnaka, HMT Nagar, Lalaguda and Nacharam as part of Greater Hyderabad, Telangana (State), India. The selected community discharges~30 MLD of domestic wastewater (sewage) which flows through the main drain starting from Lalaguda and finally covering at sampling point T8 before the STP inlet ( Figure 1 , T8 in our study is considered as the cumulative (composite) representation of all sampling points). Eight sampling points were selected across the drain system to comprehensively represent the majority of lateral drains ( Figure 1 ). Sampling points were selected in such a way as to cover the entire community sewage network. Various lateral drains join the main drain covering the adjoining domestic settlements. Samples were collected at the lateral drain before merging into the main drain. The main sewage drain of the community finally is discharged into the sewage treatment plant (STP) located at Nacharam. An optimized sampling protocol was followed to sample the domestic wastewater at the selected points based on our earlier study [22] . The grab samples were collected in a clean plastic bottle (disposable; 1.2 L) containing 20 mL of sodium hypochlorite (0.1%) to inactivate the pathogens. For sample collection, the sample container was placed slightly lowered in the opposite direction of flow with partial immersion. A grab sample volume of one litre was collected at one time with three replicates. Sample information was noted on the field sheets (date and time) along with position (GPS readings), point codes and observations. Grab samples were collected on a weekly and monthly basis. A total of eight samples were collected for weekly monitoring, starting from 7 October 2020 (Week 1), 28 October 2020 (Week 4), 4 November 2020 (Week 5), 11 November 2020 (Week 6) and 18 November 2020 (Week 7). Samples were not collected during Week 2 and Week 3 due to the heavy rainfall events, leading to the overflow of all sewage drains. Monthly samples Gravity filtration using 1 mm filter papers was conducted for the collected samples to remove the larger debris, followed by secondary filtration with 0.2 µm filtration units (Nalgene ® vacuum filtration system) to remove other fine particles and pathogens [28] . The secondary filtered sample of 60 mL was concentrated to~600 µL by using 15 mL 30 kDa Amicon ® Ultra-15 (Merck Millipore, Burlington, MA, USA) by ultra-filtration (4000 rpm; 4 • C; 10 min). A concentrated 150 µL portion of the sample was used for RNA extraction. All the sample processing and detection experiments were performed in Biosafety level 2 (BSL-2) laboratories. RNA was extracted from the concentrated samples using the Viral RNA isolation kit (Qiagen, Germantown, MD, USA) as per the provided manufacturer's protocol. DNA/RNA cross-contamination was avoided by using sterile equipment and RNase-free water for the RNA extraction [22, 28] . Isolated SARS-CoV-2 RNA was quantified by using the RT-PCR Detection Kit (Shanghai Fosun Long March Medical Science Co., Ltd., Shanghai, China) which is an FDA (Food and Drug Administration, USA Government) approved kit. Fosun RT-PCR (LoD was 300 copies/mL) contained the primers and chromophore probes encoding for the envelope protein-coding gene (E-gene; ROX), nucleocapsid gene (N-gene; JOE), and open reading frame1ab (ORF1ab; FAM) of SARS-CoV-2. In the RT-PCR assay, reverse transcription (50 • C for 15 min) and the initial denaturation (95 • C for 3 min) were followed by 5 cycles at 95 • C for 5 s and 60 • C for 40 s carried out without data acquisition and 40 cycles with acquisition. Signals from the probes (FAM (ORF1ab), JOE (N gene), ROX (E-gene) and CY5 (Internal reference) were collected by the fluorescence channels at 60 • C [28] . Positive and negative controls of the Fosun RT-PCR kit were also placed for the assay in all the amplifications [28] . C T values in the positive controls matched with given manufactured data and no C T was observed in negative control, which confirmed that the samples were free of cross-contamination. Triplicate analysis was carried out for each sample to obtain more accurate results. The E-gene, amplified from SARS-CoV-2 RNA, was cloned with KpnI and HindIII restriction sites into a pcDNA3.1 vector and quantified with Qubit™ dsDNA HS Assay Kit (Invitrogen, Carlsbad, CA, USA) and Qubit™ 4 Fluorometer (Invitrogen, Carlsbad, CA, USA). The number of copies per nanogram were calculated based on E-gene and vector sequences were obtained from https://www.ncbi.nlm.nih.gov/nuccore/NC_04 5512.2?report=fasta&from=26245&to=26472 (accessed on 20 November 2020) and https: //www.addgene.org/browse/sequence_vdb/2093/ (accessed on 20 November 2020). The plasmid was diluted from a number of 9.01 log10 to 0.01 log10 copies and RT-PCR was performed. The C T values were plotted against the log copy number and a linear fit equation (R 2 : 0.9993) was obtained [28] . This was used in calculating the number of RNA copies in wastewater based on E-gene C T values. To assess the performance of the qRT-PCR kit used in this work in terms of viral recovery efficiency, 2.14 × 10 7 pfu/mL viral culture was inactivated at 55 • C for 30 min. RNA was isolated from the heat-inactivated SARS-CoV-2 which was followed by the preparation of log10 dilutions of the RNA. RT-PCR was performed in triplicate for each dilution by following the necessary MIQE guideline. The R2 values obtained from linear regression and efficiency were calculated as described. Detailed data were provided in our previously published study [28] . Inactivated viral culture used in the study was provided to us by Dr. H. H. Krishnan, CSIR-CCMB [28] . RNA copies/L of wastewater were calculated using the linear fit equation of the E-gene (Equation (1)) [28] . The number of infected people in a selected community was calculated by using the two methods in Equations (2) and (3) [12, 29] . Method 1 [12] No.o f in f ected individuals = RN Acopies Lwater * L water day g f aeces day * RN Acopies g f aceces Faeces excreted/person/day = 128 g [30] One positive person can shed 10 7 RNA copies/g of faeces (maximum estimate) [31, 32] . Method 2 [29] No. o f in f ected individuals = Number of RNA copies/mL of faeces = 10 7 . Volume of faeces excreted = 120 mL (calculated by considering that the density of human faeces is 1.07 g/mL) [31] . Relative standard deviation (RSD) was calculated for the C T value of individual genes based on Equation (4), where X the mean of C T value and S is the standard deviation. The active phase of infected individuals in the selected sampling area was calculated by considering the total number of infected individuals (based on RNA copies), window period and infection period In f ected individuals in selected area Window period/In f ection period Window period: 14 days prior to and post sample time (i.e., 29 days in monthly monitoring, including sampling day); Infection period: 14 days (i.e., active symptomatic phase duration). SARS-CoV-2 genetic material was detected in all 40 samples collected at 8 sampling stations over the window period of 5 weeks from 7 October 2020 to 18 November 2020, with variable loads. Amplification of three SARS-CoV-2 target genes, namely, E-gene, N-gene and ORF1ab, was detected in all the samples ( Figure 2 ). Apart from the C T values, to predict the SARS-CoV-2 viral load in domestic sewage, the RNA copy number was calculated considering the linear fit drawn from the standard curve of the E-gene [28] . At the initial sampling point (South Lalaguda lateral drain; T1), RNA copies of 23,470 copies/L are depicted with the five-week average. Extending the point to the T1, which is the T2 sample (North Lalagudamain drain), showed the RNA copy number of 54,135 copies/L. An increase in the RNA copy number at the T2 might be due to the convergence of the lateral drains containing domestic sewage discharge into the main drain. Wastewater from the main drain (T2) flows continuously until the end of the selected longitudinal sampling point (Nacharam Inlet to STP; T8). The third sampling point located at Lalapet Bridge (T3) showed a relatively lower incidence of infection dynamics when compared to T1 and T2, with 17,954 RNA copies/L. Even though the main drain stream continued from the earlier sampling point, the number of RNA copies was reported as less at the T3, which might be due to the conflation of dairy processing effluents with excessive surfactants (chemical) discharged into the drain, that may disintegrate the viral RNA material. Similar observations were reported elsewhere [33] [34] [35] . Downstream from T3, the domestic sewage overflows from Pedda Cheruvu (Lake) and discharges into the main drain (T4). The relative increment in viral load was evident with T4 samples compared to T3, with RNA copies of 45,050 copies/L. In addition to samples collected in the main drain, we have collected samples from lateral drains that were flowing from the set of communities located around the main drain, and this flow finally merged into the main drain. These lateral drain sewage samples depicted marginally lower values of SARS-CoV-2 load than the main drain. RNA copies of the samples collected at T5 (Errakunta lateral drain) showed 21,757 copies/L. Similarly, the two lateral drains, T6 (VST lateral drain) and T7 (Nacharam lateral drain), presented with higher RNA copies of 119,391 and 184,664 RNA copies/L, respectively. T8 samples representing the terminal point of the main drain where the flow of all the previous sampling points converges showed 51,182 RNA copies/L. C T values of E-gene in all the sampling points ranged between 25.41 ± 1.50% and 28.73 ± 1.04% (Figure 2a) . Similarly, the C T values of the N-gene and ORF1ab were observed from 23.37 ± 3.34% to 27.54 ± 1.82% and 19.56 ± 1.33% to 28.72 ± 0.93%, respectively (Figure 2b,c) . Three individual genes' average value of sampling points from T1 to T7 correlated with the C T values observed at the last sampling point, T8. This well-defined correlation indicates the comprehensive epidemiological analysis of the selected community by considering the terminal discharge points of the drain (T8). Longitudinal and long-term sampling provided the information for the zoning of the selected area based on the severity of the viral spread among the community ( Figure 3 ). As lateral drains were coming from the domestic wastewater outlets, we selected points in such a way that each lateral point represented a defined community based on the discharged sewage. Four major lateral sampling points denote the different distinct zones (T1: Zone I, T5: Zone II, T6: Zone III and T7: Zone IV), whereas the rest of the sampling points were at the main drain that represents the extended zones area in relation to Zone I (T2: Extended Zone I, T3: Second Extended Zone I and T4: Third Extended Zone I). Finally, the terminal sampling point (T8) represents the entire study area, considered as the cumulative major zone. Weekly monitoring to each point over the period of five weeks assisted in studying the spread of the viral genome in the wastewater. The viral genome was detected in all points of sampling in all the weeks, with dynamic changes suggesting the active spread of COVID-19 among the communities. Due to the dynamic variations in the infection rates among the eight sampling points, four zones were divided based on the intensity of infection. Infection rates were calculated for all the zones, along with cumulative community rates, by considering 10 6 RNA copies/mL and 10 7 RNA copies/mL shedding per person (Table 1) . For better understanding, we have discussed the infection rates with 10 7 RNA copies/mL. The number of infected individuals per 1MLDof sewage ranges between 15 and 1500 persons/MLD in all the zones, including distinct and extended. All the zones were categorized into three major classes (Red, Orange and Green) based on the severity of infection. Zones with infection rate <20 persons/MLD were considered as Green zones, where the spread of virus among the community was lower. Zones reporting infection rates >50 persons/MLD were categorized in the Red, representing communities that were more prone to infection with COVID-19. Besides the distinct zones of lateral drains, extended zones of main drain sampling points were also considered for calculating the infection rates where the sewages and populations of two or more distinct zones are jointly represented. Zone I, portraying the south Lalaguda (T1), showed an infection rate of 19 and is considered a Green zone. The T1, T2 sampling point was at the mainstream, so that was considered as the first extended area of Zone I. In the first extension of Zone I, the infection rate was reporting with 63. Though there was a lower infection rate in Zone I, coming to the first extended region the infection rate was significantly increased, thus, this zone was considered Orange (because of joint community and sewage merging). After the T2, sampling points T3 and T4 were in same main drain representing the area of Lalapet and PeddaCheruvu (small). Due to the main stream sewage sampling, these areas were considered as the second and third extended areas of Zone I, with infection rates of 77 and 114. Infection rates in the extended areas consistently increased with the longitudinal increment in the sampling. This is due to the merging of the discharged sewage and join representation of the community. Though there was an infection rate that was >50, these extended zones were considered as the Orange zones, with moderate infection rates. Sampling point T7 (Errakunta) at the lateral sewage drain represented the distinct separate zone (Zone II) where the infection rate (18) was more or less similar to Zone I and is considered a Green zone. Similarly, T6 (VST colony) and T7 (Nacharam) sampling points were lateral sewage drains denoting the two separate independent zones (Zone III and Zone IV). Both the zones were considered as Red zones with infection rates of 96 (Zone III) and 149 (Zone IV). After T7, sampling point T8 (STP inlet) represents the all the zones and is considered as the cumulative major zone, as it is placed nearer to the STP, Nacharam and all lateral and main streams enter into it. Infection rate in the complete major zone (study area) is 418, showing the dynamic and extensive spread of the virus among the population. Among all zones, Nacharam PS areas (Zone IV) were more prone to infection, with a higher number of 149 persons/MLD infection rate, followed by Zone III. In Green zones (T1, T5), E-gene C T values were reported~28 and above ( Figure 4 ). Particularly, in first two weeks of analysis, C T values were reported as very high,~31, suggesting the lower spread of the virus, but later on in the third week, higher infections occurred with lower C T values followed by consistent decrease in subsequent weeks. Green zones depicted a similar trend of E-gen C T values over the five weeks of study. Among the eight sampling points, two areas were categorized in the Orange region (T2, T3 and T4) with a greater prone-to-infection rate when compared to the Green regions, with C T of~27. The C T value profile over the period of five weeks was reported in the dynamic way, with increased and decreased values and vice versa. Dynamics in the C T values of the Orange zones indicate the persistent infection among the community in respect to the extended area of Zone I. Lower C T values <27 were reported in regions of T6 and T7, with these sampling points considered as Red zones with severe infection. Zoning of the selected community helps deliver early warning signals of viral spread in the respective community to tackle and prepare for the pandemic. Apart from the weekly monitoring, the dispersive and dynamic viral presence in the domestic sewage was also assessed with long-term (monthly) analysis by selecting the final drain point (T8) as a sampling station, along with a few other stations (T4 to T8). The presence of the three target genes was detected for nine months in one year of monitoring along with samples with variable RNA copy numbers ( Figure 5 ). In July, when the virus was present with 46,527 RNA copies/L after the first month of sampling, multiple rainfall events occurred due to the seasonal monsoon across the Deccan Plateau. Due to the overflow in the drains, sample collections were paused in August and September and were resumed after the flow became normal. In October 2020, 42,772 RNA copies/L were detected, which is more or less similar to July's viral load analysis data. Specifically, the samples collected during November 2020 showed a higher viral load of 61,160 RNA copies/L with lower E-gene C T values (26.99 ± 0.09%) compared to other monthly samples. This suggests the possibility of high infection rates during November 2020. In December 2020, a considerable drop in the viral load with 20,624 RNA copies/L was recorded, indicating the tapering off of viral load within the community and thus suggesting a decrease in the infection rate. To maintain the accuracy of sampling, from January 2021, samples were collected in five (in some cases three) sampling stations among the eight sampling stations. The viral load during January 2021 reported the lowest infection rates, with 2036 RNA copies/L, and had the highest E-gene C T value at 30.44 ± 0.84% compared to nine months of viral detection. However, compared to January 2021, February 2021 samples showed a marginal increase in viral load with 5228 RNA copies/L, which decreased in the subsequent month of March 2021 with 2781 RNA copies/L. In one year study, a greater number of samples were analyzed during the months of October 2020 and November 2020 because of the weekly sampling and monitoring conducted during that period. T3 and T4) with a greater prone-to-infection rate when compared to the Green regions, with CT of ~27. The CT value profile over the period of five weeks was reported in the dynamic way, with increased and decreased values and vice versa. Dynamics in the CT values of the Orange zones indicate the persistent infection among the community in respect to the extended area of Zone I. Lower CT values <27 were reported in regions of T6 and T7, with these sampling points considered as Red zones with severe infection. Zoning of the selected community helps deliver early warning signals of viral spread in the respective community to tackle and prepare for the pandemic. After the early May 2021 analysis, the number of RNA copies again showed the declining trend and did not detect the viral genome in the June, July and August 2021 samples. This might be due to the dissolution period of the second wave and individual immune development. In the detection period, C T values of E-gene ranged from 26.99 ± 0.09% to 31.84 ± 0.83%, whereas N-gene and ORF1ab ranged between 25.99 ± 0.35% to 30.45 ± 2.22% and 26 ± 0.41% to 28.89 ± 2.70%, respectively (Table 2 ). Consistent stabilization of RNA copies from April suggested the decline in the infection rates in the upcoming short time period (~15 to 30 days). Temporal variation in the number of infected individuals was observed in our analysis. Such variation might be caused by various factors including infection rate, loss of viral RNA during transit from the source to the sampling site, presence of deteriorating agents in the wastewater samples, and differences in the amount of virus shed by infected individuals. Reports show a loss of 0.02 to 3000 RNA copies/mL during the passage of faecal matter from the point of defecation to the sewage drain [31] . Based on the RNA copy number detected in the weekly samples, virus spread in the community was predicted by considering the volume of sewage discharge as well as the population of the selected community ( Figure 2 and Table 3 ). Estimated numbers of infected individuals in the selected community were calculated based on two methods [12, 29] . In the present study, 10 7 RNA copies/mL faeces was used for the description of epidemiological spread [22, 28] . The number of infected individuals in the studied community is based on a total window period of 77 days (which includes 14 days each before and after the sampling period combined with 49 days of the sampling period). The window period was selected based on the reports that showed the persistence of SARS-CoV-2 genetic material in the fae-cal matter of infected individuals before, during and after the active infection phase [14, 36] . The probable number of infected individuals in the studied community (77 days window period) was 1567, with 285 people being in the active phase of infection (Table 3 ). The community under study covers a population of~2.5 lakhs, which represents~1.79% of the total Hyderabad city population, considering the number of infected individuals in the selected community with 30 MLD domestic sewage flow (i.e., 1.6% of total sewage flow of 1800 MLD of Hyderabad city) [37] . An extrapolation was performed to arrive at the total number of infected individuals of the city, which was calculated to be 94,018, with about 17,094 active phase individuals. The infection rate of 52 persons/MLD was derived based on infected individuals and population figures ( Table 3) . Using the monthly monitoring data, the number of infected individuals was calculated during each month individually ( Table 4 ). The number of infected individuals in the month of July 2020 was recorded as 1127 (study area) and 67,610 (total city), with active phase individuals of 537 and 32,195. After the rainfall event during the months of August and September, the number of infected individuals reported in October 2020 was more or less similar to that in July 2020, wherein infected/active phase individuals in the study area and the entire city were 1036/493 and 62,153/29,597, respectively. Marginal variation from July to October indicates the consistent spread of the viral load among the community. However, in November 2020, the infection rates rose significantly (infected/active, 1481/705 (study area); 88,873/42,321 (city)). A substantial increase in the number of infected individuals in November 2020 suggests widespread SARS-CoV-2 infection in the community. In subsequent months, December 2020 showed a substantial drop in infection (499/238 study area); (29,969/14,271 city). This decrease was observed in January 2021, with a minimal number of infections ((infected/active, 49/23 (study area); 2959/1409 (Hyderabad)) when compared to the nine months of viral detection in the one-year study. However, February 2021 data indicated a minor increase in infected individuals of 127 and 7597 in the study area and Hyderabad city, respectively, having an active phase individual count of 60 (selected community) and 3618 (Hyderabad) compared to January 2021 and followed by a decrease in March 2021 (67/32 study area; 4041/1924 in city). The WBE tool is one of strategies used to track the disease dynamics of viral infections in a given community with minimal samples. Longitudinal sampling from the different selected points provides an appropriate state of viral infection within the selected community [39, 40] . The number of infected individuals reported in the present study includes pre-and post-symptomatic, asymptomatic and mildly symptomatic individuals. Associated with clinical data, WBE could provide critical monitoring of SARS-CoV-2 transmission within a community including the beginning, tapering off or reemergence of the virus [41] [42] [43] [44] [45] . The WBE studies of infectious pathogens offer unbiased monitoring of infection prevalence, spreading rate and dynamics of infection in terms of special and temporal avenues. Previously, we estimated the percentage of infected population in Hyderabad based on the sewage viral load detected in various sewage treatment plants (STPs) across the city. In view of the fast spreading ability of SARS-CoV-2 over time, it is mandatory to establish the potential surveillance approach to the community level for better management of the infection. In this work, we presented the long-term SARS-CoV-2 sewage surveillance by longitudinal sampling in a selected community. As previously described, we calculated the number of infected individuals based on the viral RNA copies present in sewage water. The viral load in the samples at different time points clearly indicated the infection dynamics during the study time of one year. Our calculation showed the maximum number of infected individuals during the month of November, which is in agreement with the clinical diagnostic data during the same period of time. This observation clearly supports the advantage of sewage surveillance at the community level, which could help in providing better clinical care. In addition, we noticed a pattern in the viral load in sewage samples. It reached a saturation or steady state at some point during the time course and gradually decreased later. The calculated percentage of the infected population from long-term surveillance not only aids in understanding the disease dynamics but also provides an opportunity to predict the establishment of herd immunity among the population. This can be achieved by calculating the number of infected individuals' overtime with respect to the total population. Since the estimations are purely based on the sewage viral load; the sampling conditions play crucial roles. To achieve clear and reliable estimations, it is important to observe the viral load trends for more than onetime point. If there is a sudden rise in the viral load, repeated periodical sampling and assessment would help in reaching better and more comprehensive conclusions. For long term surveillance, sampling and processing shall be performed once or twice every month from different communities or areas. The occurrence of SARS-CoV in sewage originating from the hospital during the SARS-CoV-1 outbreak was tested for its virulence/occurrence before and after disinfection using a symptomatic patient sample [46] . Genomic material of the virus could be detected by targeting the specific coding genes through the RT-PCR. The detection of the virus in sewage when the SARS-CoV-2 prevalence was low indicated the functional role of sewage for surveillance to monitor the circulation of the virus in the population via wastewater-based epidemiology (WBE) [28, 47] . The surveillance/monitoring of SARS-CoV-2 in wastewater could be able to quantify the scale of infection prevailing among the community, with the benefit of detecting the virus from symptomatic, asymptomatic or pre-symptomatic cases which manifest as an early-warning sign ( Table 5 ). The WBE approach will help to minimize the outbreak spread and also serve for future epidemic surveillance. NA-Information not provided. The spread and persistence of SARS-CoV-2 infection was studied by detecting the viral genetic material in the domestic sewage using the longitudinal grab sampling protocol in a selected community through a long-term epidemiological surveillance. Sample collection from the lateral drains along with the mainstream provided information about the dynamics of infection among the community. The detection of viral genetic material in the sewage over the period of nine months indicates the persistence of SARS-CoV-2 among the studied community. Considering the capacity of sewage generation, we have calculated the number of infected peoples along with the active infectious phase. Based on the long-term representative sampling, we have tried to extrapolate data to the total city to understand the dynamics of the outbreak of the virus. Continuous monitoring over the period of nine months, including weekly monitoring, helped to understand the viral load in the selected community based on the discharged domestic wastewater and assisted in determining the infection status of the particular community as well as zoning of the community based on the infection rate. This WBE study offers an early warning system as well as provides a clear view of infection dynamics and immunity status of the population, as asymptomatic, symptomatic and pre-symptomatic individuals shed virus. Moreover, these findings are unbiased. Performing WBE studies can be extended to the surveillance of other infectious pathogens, as the method is simple to perform yet efficient enough to help understand the infection type and dynamics among the population in a temporal manner. Environmental surveillance for polioviruses in the Global Polio Eradication Initiative The challenges of informative wastewater sampling for SARS-CoV-2 must be met: Lessons from polio eradication Novel multiplexed amplicon-based sequencing to quantify SARS-CoV-2 RNA from wastewater Wastewater-Based Epidemiology for Early Detection of Viral Outbreaks Rapid and sensitive direct detection and identification of poliovirus from stool and environmental surveillance samples by use of nanopore sequencing SARS-CoV-2 RNA in wastewater anticipated COVID-19 occurrence in a low prevalence area SARS-CoV-2 in environmental perspective: Occurrence, persistence, surveillance, inactivation and challenges Tracking SARS-CoV-2 RNA through the wastewater treatment process Inactivation of an enveloped surrogate virus in human sewage Censored regression modeling to predict virus inactivation in wastewaters Differences in viral disinfection mechanisms as revealed by quantitative transfection of echovirus 11 genomes Surveillance of SARS-CoV-2 RNA in wastewater: Methods optimization and quality control are crucial for generating reliable public health information First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community SARS-CoV-2 titers in wastewater are higher than expected from clinically confirmed cases Time course quantitative detection of SARS-CoV-2 in Parisian wastewaters correlates with COVID-19 confirmed cases First detection of SARS-CoV-2 in untreated wastewaters in Italy Presence of SARS-Coronavirus-2 RNA in Sewage and Correlation with Reported COVID-19 Prevalence in the Early Stage of the Epidemic in The Netherlands Existence of SARS-CoV-2 in wastewater: Implications for its environmental transmission in developing communities Correlation of SARS-CoV-2 RNA in wastewater with COVID-19 disease burden in sewersheds Environmental surveillance of poliovirus in sewage water around the introduction period for inactivated polio vaccine in Japan Novel wastewater surveillance strategy for early detection of coronavirus disease 2019 hotspots Defining the methodological approach for wastewater-based epidemiological studies-Surveillance of SARS-CoV-2 Monitoring wastewater for assessing community health: Sewage Chemical-Information Mining (SCIM) Collection of SARS-CoV-2 Virus from the Air of a Clinic within a University Student Health Care Center and Analyses of the Viral Genomic Sequence COVID-19: The environmental implications of shedding SARS-CoV-2 in human faeces Can a paper-based device trace COVID-19 sources with wastewater-based epidemiology? Computational analysis of SARS-CoV-2/COVID-19 surveillance by wastewater-based epidemiology locally and globally: Feasibility, economy, opportunities and challenges Surveillance of SARS-CoV-2 spread using wastewater-based epidemiology: Comprehensive study Detection of pathogenic viruses in sewage provided early warnings of hepatitis A virus and norovirus outbreaks The characterization of feces and urine: A review of the literature to inform advanced treatment technology SARS-CoV-2 from faeces to wastewater treatment: What do we know? A review Wastewater-based epidemiology: Global collaborative to maximize contributions in the fight against COVID-19 Physico-chemical treatment of dairy industry wastewaters: A review. Technological Approaches for Novel Applications in Dairy Processing An environmental and health perspective for COVID-19 outbreak: Meteorology and air quality influence, sewage epidemiology indicator, hospitals disinfection, drug therapies and recommendations Detection of SARS-CoV-2 in raw and treated wastewater in Germany-suitability for COVID-19 surveillance and potential transmission risks Measurement of SARS-CoV-2 RNA in wastewater tracks community infection dynamics Understanding SARS-CoV-2 Infection and Dynamics with Long Term Wastewater Based Epidemiological Surveillance Number of People in Hyderabad with Covid Antibodies Could Be Much More than Sero-Survey Results Analytical methodologies for the detection of SARS-CoV-2 in wastewater: Protocols and future perspectives SARS-CoV-2 existence in sewage and wastewater: A global public health concern? Possible transmission of viruses from contaminated human feces and sewage: Implications for SARS-CoV-2 Survival of coronaviruses in water and wastewater Epidemiological evaluation of sewage surveillance as a tool to detect the presence of COVID-19 cases in a low case load setting Tracking COVID-19 via sewage CoV-2: Sewage surveillance as an early warning system and challenges in developing countries Concentration and detection of SARS coronavirus in sewage from Xiao Tang Shan Hospital and the 309th Hospital Comparative study of viromes from freshwater samples of the Ile-Balkhash region of Kazakhstan captured through metagenomic analysis First proof of the capability of wastewater surveillance for COVID-19 in India through detection of genetic material of SARS-CoV-2 Preliminary results of SARS-CoV-2 detection in sewerage system in Niterói municipality SARS-CoV-2 RNA detection of hospital isolation wards hygiene monitoring during the Coronavirus Disease 2019 outbreak in a Chinese hospital Preliminary study of Sars-Cov-2 occurrence in wastewater in the Czech Republic SARS-CoV-2 in wastewater: Potential health risk, but also data source First environmental surveillance for the presence of SARS-CoV-2 RNA in wastewater and river water in Japan First detection of SARS-CoV-2 RNA in wastewater in North America: A study in Louisiana COVID-19 surveillance in Southeastern Virginia using wastewater-based epidemiology Xagoraraki, I. SARS-CoV-2 in Detroit wastewater Tracking COVID-19 with wastewater to understand asymptomatic transmission A novel passive sampling approach for SARS-CoV-2 in wastewater in a Canadian province with low prevalence of COVID-19 Reliability of wastewater analysis for monitoring COVID-19 incidence revealed by a long-term follow-up study. Front. Virol. 2021 Detection of SARs-CoV-2 in wastewater using the existing environmental surveillance network: A potential supplementary system for monitoring COVID-19 transmission Detection of SARS-CoV-2 in wastewater is influenced by sampling time, concentration method, and target analyzed COVID-19 wastewater epidemiology: A model to estimate infected populations Long-term monitoring of SARS-CoV-2 RNA in wastewater of the Frankfurt metropolitan area in Southern Germany Comprehensive and temporal surveillance of SARS-CoV-2 in urban water bodies: Early signal of second wave onset Conflicts of Interest: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.