key: cord-0823239-8u93eqne authors: Yan, Ying; Chang, Le; Luo, Wenxin; Liu, Junyi; Guo, Fei; Wang, Lunan title: Comparison of seven commercial SARS-CoV-2 nucleic acid detection reagents with pseudovirus as quality control material date: 2020-12-29 journal: J Mol Diagn DOI: 10.1016/j.jmoldx.2020.12.002 sha: 06c8f6124a33ce2fc42e2be8e4ff746e5ad576c3 doc_id: 823239 cord_uid: 8u93eqne The ongoing pandemic of COVID-19 threats the whole world, which catalyzes a variety of SARS-CoV-2 nucleic acid test (NAT) kits. To monitor test quality and evaluate NAT kits, quality control materials that best simulate real clinical samples are needed in this study, the performance of SARS-CoV-2 cell culture supernatant, PCDH-based pseudovirus, and MS2-based pseudovirus as quality control materials was compared. As a result, PCDH-based pseudovirus was more similar in characteristics to SARS-CoV-2 particle, and was more suitable for evaluating SARS-CoV-2 NAT kits than MS2-based pseudovirus. Proper detection using sensitive and precise NAT kits is essential to guarantee diagnosis. Thus, limit of detection, precision, anti-inference ability and cross-reactivity of NAT kits from PerkinElmer, Wantai, Shanghai Kehua Bio-Engineering (KHB), Sansure, Da An, BioGerm, and Applied Biological Technologies (ABT) were compared using PCDH-based pseudovirus. For the seven kits evaluated, N gene was more sensitive than ORF1ab gene in most kits, while E gene was most sensitive among the three genes in KHB and ABT. PerkinElmer got the lowest LoD for N gene at 11.61 copies/mL, and 34.66 copies/mL for ORF1ab gene. All the kits showed good precision with CV values less than 5%, as well as acceptable anti-interference ability of 2 mg/L human genomic DNA. No cross-reactivity was observed with other respiratory viruses. Rapid and accurate diagnosis of SARS-CoV-2 is essential for early discovery and early treatment. Due to its easy methodology, high sensitivity and specificity, real time reverse transcription-polymerase chain reaction (RT-PCR) is becoming the optimal and most widely used method for detecting nucleic acid, and even the "gold standard" for viral detection 1 . Multiple commercial real time RT-PCR assays have been developed to meet diagnostic needs for SARS-CoV-2. However, clinical confirmed patients with negative nucleic acid test (NAT) results have been reported 2, 3 . Comparing the performance of commonly used NAT kits, and providing evidence for choosing sensitive, specific and precise NAT kits are the key to obtaining reliable test results. Quality control materials are needed for evaluating the performance of SARS-CoV-2 NAT kits. Although patient samples are most in line with the actual situation, difficulty in obtaining samples and the risk of transmission limit their J o u r n a l P r e -p r o o f application as quality control materials. Therefore, construction of pseudoviruses similar to SARS-CoV-2 virus is necessary to evaluate the performance of NAT kits, as well as to control the quality of experimental procedure. Vectors of lentivirus and bacteriophage have been widely used to produce stable quality control materials [4] [5] [6] [7] . These vectors vary in their characteristics including size, packaging capacity, and stability. To best simulate real patient samples, the performance of different quality control materials needs to be compared. In this study, the applicability of MS2-based pseudovirus and PCDH-based pseudovirus containing the amplification regions of SARS-CoV-2 NAT kits was compared with that of SARS-CoV-2 cell culture supernatant. Furthermore, limit of detection, precision, anti-inference ability, and cross-reactivity of seven CE marked and widely used SARS-CoV-2 NAT kits were evaluated using PCDH-based pseudovirus. Three kinds of quality control materials were constructed. SARS-CoV-2 cell culture supernatant was kindly gifted by Chinese Academy of Military Medical Sciences (GenBank, https://www.ncbi.nlm.nih.gov/nuccore; accession number MT135042.1). Briefly, virus was cultured in Vero-E6 cells for 96 hours, then the supernatant was collected and disinfected by heating at 65℃ for 30 minutes 8 . For constructing J o u r n a l P r e -p r o o f PCDH-based pseudovirus ( Figure 1A ), PCDH-CMV-MCS-EF1-copGFP vector was digested with enzymes NotI and SalI, and the product was gel purified. N gene, E gene, and segments of ORF1ab gene were synthesized with overlapping ends by PCR, and further cloned into digested PCDH vector using one step of Gibson assembly (NEB, MA, US) at 50℃ for one hour. The resultant plasmid was electroporated into ER2738 electrocompetent cells (Lucigen, WI). After recovery in SOC medium at 37℃ for one hour, the ER2738 cells were spread onto LB solid medium with 8m/L glucose and 50mg/L ampicillin and incubated at 37 ℃ overnight. Positive clones were sequenced, and successfully constructed plasmid was extracted. Then, HEK293T cells were seeded in 10 cm dish. After 24 h, PCDH plasmid, two packaging plasmids psPAX and pMD2G were transfected at the ration of 4:3:1 using polyethylenimine (Polysciences, PA). Supernatant was gathered 48 hours after transfection, and centrifugated at 2000 rpm for 5 minutes to remove cell debris. For constructing MS2-based pseudovirus ( Figure 1B ), pGSI-MS2 vector was digested with NotI and BamHI, and gel purified. N gene, E gene, and nine segments of ORF1ab gene were synthesized, ligated into MS2 vector respectively, and transformed into competent E. coli cells. Products were harvested, sonicated and purified as before 9 . Finally, MS2-based pseudovirus containing different regions of SARS-CoV-2 genome were mixed together with the same volume ratio so that it can contain all the target sequences of all regents evaluated. After production, materials were stored at -40℃. J o u r n a l P r e -p r o o f Digital PCR Quality control materials were diluted to about 10 5 copies/mL, and sent to reagent manufacturers. Digital PCR was conducted using the same primers and probes as in their NAT kits and the median of all results were taken as the exact concentration of quality control materials. The detail information of digital PCR conducted by each manufacturer were summarized in Supplemental Table S1 . The process of digital PCR was indicated before. 10 Real time RT-PCR Seven SARS-CoV-2 NAT kits were included. They were from PerkinElmer, Inc Table S2 . For stability test, three quality control materials were diluted to about 1000 copies/mL using dulbecco's modified eagle medium (DMEM) (Corning, NY, USA) containing 0.1% ProClin 300. Each material was thoroughly mixed and divided into four groups. Control group was stored at -40℃ for two weeks. To assess freeze-thaw stability, materials were stored at -40℃ for two weeks, during which they were frozen and thawed 3 times repeatedly. To evaluate whether the materials are stable after opening the tubes, materials were stored at -40℃ for a week and tubes were open for a while, then they were stored at 2-8℃ for a week. For fundamental stability, materials were stored at room temperature for a week and then put at 2-8℃ for another week. After processing, the nucleic acids were extracted using PerkinElmer PreNAT II, and tested Quantification of three quality control materials J o u r n a l P r e -p r o o f SARS-CoV-2 cell culture supernatant, MS2-based pseudovirus, and PCDH-based pseudovirus were diluted 10-fold, 1000-fold, and 10000-fold respectively. Digital PCR was performed to quantify N gene, E gene and ORF1ab gene by six reagent manufacturers except BioGerm. As seen in Figure 2 , concentration of quality control materials varied from 4-6 log10 copies/mL, so that median was taken as the final concentration. Among the three quality control materials, PCDH-based pseudovirus showed the smallest variation both among reagents and among genes. Three kinds of quality control materials were processed at four conditions indicated before. Real time RT-PCR using PerkinElmer's kit was performed thereafter. As seen in Figure 3 and supplemental Table S3 , the difference in mean Ct values of ORF1ab gene between each experimental group and control group was all less than 0.5. However, when evaluating fundamental stability of cell culture supernatant, the Ct value of N gene was 0.76 higher than control group, indicating that it might be unstable at this condition. Amplification efficiency among quality control materials Three kinds of quality control materials were diluted in a 5-fold gradient between 100,000 copies/mL to 800 copies/mL, and real time RT-PCR was performed using seven kits evaluated. As seen in Figure 4 , the amplification efficiencies of N gene and J o u r n a l P r e -p r o o f Since low concentration was near the LoD of several reagents, the positive rate was not 100% for all reagents. As seen in Table 3 , 2 mg/L human genomic DNA didn't interfere with the determination of positive results of the Wantai kit. As for PerkinElmer, the positive rate of ORF1ab gene slightly reduced from 100% to 90%. For the kits with less sensitivity, positive rates were compared. For ORF1ab gene of KHB, and both N and ORF1ab gene of ABT, the positive rate of interfering group is a J o u r n a l P r e -p r o o f bit lower than that of control group. For ORF1ab gene of Sansure and BioGerm, the positive rate was higher in interfering group than in control group. As seen in Table 4 produced was about 1×10 9 copies/mL. Since the three regions were inserted together, it is assumed that the concentrations of three regions are the same. However, although ddPCR can precisely quantify nucleic acids, the process is subject to bias and variance. 12 Therefore, the concentrations of three regions are not identical. For N gene, the concentration was 90 copies/mL for PerkinElmer, 180 copies/mL for Wantai and KHB, and 360 copies/mL for other reagents. For ORF1ab gene, the concentration was 76 copies/mL for PerkinElmer, 152 copies/mL for Wantai and KHB, and 304 copies/mL for other reagents. For E gene, the concentration was 134 copies/mL for KHB, and 268 copies/mL for ABT. Undetermined results were excluded. Quantification of mRNA using real-time RT-PCR Negative Nasopharyngeal and Oropharyngeal Swabs Do Not Rule Out COVID-19 Real-time RT-PCR in COVID-19 detection: issues affecting the results Laboratory testing of SARS-CoV, MERS-CoV, and SARS-CoV-2 (2019-nCoV): Current status, challenges, and countermeasures Construction of Lentivirus-Based Reference Material for RT-PCR Detection of Middle East Respiratory Syndrome Coronavirus and Its Application in External Quality Assessment Preparation of MS2-based nanoparticles as control and standard materials for the molecular detection of dengue virus serotypes External quality assessment for the molecular detection of MERS-CoV in China Development of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) thermal inactivation method with preservation of diagnostic sensitivity Armored long non-coding RNA MEG3 targeting EGFR based on recombinant MS2 bacteriophage virus-like particles against hepatocellular carcinoma No Evidence of SARS-CoV-2 RNA among blood donors: A Multicenter Study in Hubei Gene delivery by lentivirus vectors Considerations for digital PCR as an accurate molecular diagnostic tool Armored RNA technology for production of ribonuclease-resistant viral RNA controls and standards RNase-resistant virus-like particles containing long chimeric RNA sequences produced by two-plasmid coexpression system China Novel Coronavirus I, Research T: A Novel Coronavirus from Patients with Pneumonia in China Mass determination of rous sarcoma virus virions by scanning transmission electron microscopy New developments in lentiviral vector design, production and purification A novel delivery platform based on Bacteriophage MS2 virus-like particles Potential false-negative nucleic acid testing results for Severe Acute Respiratory Syndrome Coronavirus 2 from thermal inactivation of samples with low viral loads Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study The Architecture of SARS-CoV-2 Transcriptome The concentration was 900 copies/mL of N gene, 760 copies/mL of ORF1ab gene, and 670 copies/mL of E gene The authors thank Chinese Academy of Military Medical Sciences for providing SARS-CoV-2 cell culture supernatant, thank PerkinElmer, Wantai, KHB, Sansure, Da An, BioGerm and ABT for supplying NAT kits and performing these tests, as well as PerkinElmer and Da An for providing other respiratory viruses.J o u r n a l P r e -p r o o f