key: cord-0822933-nbdv0bna authors: Lin, Po-Ting; Ni, Ting-Yuan; Chen, Tren-Yi; Su, Chih-Pei; Sun, Hsiao-Fen; Chen, Mu-Kuan; Chou, Chu-Chung; Wang, Po-Yu; Lin, Yan-Ren title: Reducing the consumption of personal protective equipment by setting up a multifunctional sampling station in the emergency department to screen for COVID-19 infection in Taiwan date: 2020-07-30 journal: Environ Health Prev Med DOI: 10.1186/s12199-020-00874-5 sha: babd7d9f829656886b9dd16731220105fb35de8d doc_id: 822933 cord_uid: nbdv0bna In Taiwan, high-risk patients have been identified and tested for preventing community spread of COVID-19. Most sample collection was performed in emergency departments (EDs). Traditional sample collection requires substantial personal protective equipment (PPE), healthcare professionals, sanitation workers, and isolation space. To solve this problem, we established a multifunctional sample collection station (MSCS) for COVID-19 testing in front of our ED. The station is composed of a thick and clear acrylic board (2 cm), which completely separates the patient and medical personnel. Three pairs of gloves (length, 45 cm) are attached and fixed on the outside wall of the MSCS. The gloves are used to conduct sampling of throat/nasal swabs, sputum, and blood from patients. The gap between the board and the building is only 0.2 cm (sealed with silicone sealant). ED personnel communicate with patients using a small two-way broadcast system. Medical waste is put in specific trashcans installed in the table outside the MSCS. With full physical protection, the personnel conducting the sampling procedure need to wear only their N95 mask and gloves. After we activated the station, our PPE, sampling time, and sanitization resources were considerably conserved during the 4-week observation period. The MSCS obviously saved time and PPE. It elevated the efficiency and capacity of the ED for handling potential community infections of COVID-19. The outbreak of COVID-19 has devastated the community and health care facilities [1] . Nationwide extensive screening of potential COVID-19 patients might be beneficial for early identification, treatment, and the development of an isolation policy [2] . However, for some countries that are facing potential community infections and are not truly in the epidemic stage, extensive screening might rapidly consume the current personal protective equipment (PPE) and hospital capacity resources and may even result in resource insufficiency in the subsequent epidemic stage [3] . Therefore, tracing and identification of high-risk patients, especially those with positive travel, occupation, contact, and cluster (TOCC) histories, would be very useful before the epidemic stage. More importantly, rapid sample collection and examination without much PPE or hospital capacity consumption would maintain the normal functioning of emergency departments (EDs) and even the whole health care system. In Taiwan, high-risk patients have been identified and tested (by the recommendation of the Taiwan CDC) for preventing potential COVID-19 community spread. Most of the sample collection was performed in EDs. Traditional methods for sample collection require substantial PPE, healthcare professionals, sanitation workers, and isolation space. These methods are also very time consuming, requiring wearing and removing the PPE with repeated sampling and sanitization. To solve this problem, we established a multifunctional sample collection station (MSCS) for COVID-19 testing in front of our ED. This station is composed of a thick and clear acrylic board that completely separates the patient and medical personnel. Detailed information regarding the measurements is provided in Fig. 1 . Three pairs of gloves (length, 45 cm) are attached and fixed on the outside wall of the MSCS. The gloves are used to conduct sampling of throat/nasal swabs, sputum, and blood from patients. The thickness of the acrylic board on the MSCS is 2 cm. The gap between the board and building is only 0.2 cm (sealed with silicone sealant). ED personnel communicate with patients using a small two-way broadcast system (with fixed microphones and speakers on the wall). Medical waste (including alcohol-soaked cotton and tongue depressor) is placed in specific trashcans (15 cm 2 , depth 20 cm), which are installed in the table outside the MSCS. With full physical protection, the personnel who conduct the sampling procedure need to wear only their N95 mask and gloves (Fig. 2) . Each ED patient rapidly received outdoor body temperature measurements and TOCC examinations conducted by machines and triage counter personnel. If they were identified as having a high/moderate risk of COVID-19 infection, they received a quick evaluation in separate risk-associated waiting areas [4] . After initial evaluation of a chest image, virus testing for COVID-19 was performed in the MSCS (including throat/nasal swab, sputum collection, blood testing for antibody). This station served only one patient at a time (reducing the risk of crossinfection). Once the patients completed the tests, they could be discharged directly from station and await their reports at home. After we activated the station, our PPE, sampling time, and sanitization resources were considerably conserved during the 4-week observation period. A comparison between traditional sampling (in a single negative-pressure isolation room) and using the MSCS (outside of the ED) is shown in Table 1 . In conclusion, the MSCS considerably saved time and PPE. It elevated the efficiency and capacity of the ED when handling potential community infections of COVID-19. The impending storm: COVID-19, pandemics and our overwhelmed emergency departments Home care for patients with suspected novel coronavirus (nCoV) infection presenting with mild symptoms and management of contacts Novel coronavirus and old lessons -preparing the health system for the pandemic Buffer areas in emergency department to handle potential COVID-19 community infection in Taiwan None. 1 Department of Emergency and Critical Care Medicine, Changhua Christian Hospital, Changhua, Taiwan. 2 Received: 1 July 2020 Accepted: 22 July 2020 Po-Ting Lin and Yan-Ren Lin conceptualized and designed the study. Po-Ting Lin and Ting-Yuan Ni helped draft the manuscript. Tren-Yi Chen, Chih-Pei Su, and Hsiao-Fen Sun collected the data and prepared the table and figures. Mu-Kuan Chen, Chu-Chung Chou, and Po-Yu Wang reviewed and provided conceptual advice for the manuscript. Yan-Ren Lin and Mu-Kuan Chen revised the manuscript. The authors read and approved the final manuscript. None.Availability of data and materials Not applicable.Ethics approval and consent to participate Institutional Review Board of Changhua Christian Hospital permission number 200409. Not applicable. None.Author details