key: cord-0822219-n32pznu5 authors: Redmond, Sarah N.; Dousa, Khalid M.; Jones, Lucas D.; Li, Daniel F.; Cadnum, Jennifer L.; Navas, Maria E.; Kachaluba, Nataliya M.; Silva, Sandra Y.; Zabarsky, Trina F.; Eckstein, Elizabeth C.; Procop, Gary W.; Donskey, Curtis J. title: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid contamination of surfaces on a coronavirus disease 2019 (COVID-19) ward and intensive care unit date: 2020-08-12 journal: Infection control and hospital epidemiology DOI: 10.1017/ice.2020.416 sha: f5dc08c7fbf84de386e03b1c6b35c74275e4c7be doc_id: 822219 cord_uid: n32pznu5 On coronavirus disease 2019 (COVID-19) wards, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid was frequently detected on high-touch surfaces, floors, and socks inside patient rooms. Contamination of floors and shoes was common outside patient rooms on the COVID-19 wards but decreased after improvements in floor cleaning and disinfection were implemented. Transmission of respiratory viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), commonly occurs through exposure to respiratory droplets. 1, 2 The importance of contaminated surfaces in transmission is uncertain. 2 However, respiratory viruses can survive for hours to days on surfaces. 1, 3 Therefore, minimizing contact with surfaces, hand hygiene after surface contact, and environmental cleaning and disinfection are recommended to reduce risk for acquisition of SARS-CoV-2. 2 In healthcare facilities, surfaces in rooms of patients with coronavirus disease 2019 (COVID-19) are frequently contaminated with SARS-CoV-2 nucleic acid. 4 Widespread SARS-CoV-2 nucleic acid contamination outside the rooms of infected patients has also been reported. 5, 6 To develop effective interventions, there is a need for additional data on environmental contamination. Here, we examined SARS-CoV-2 contamination of surfaces on a COVID-19 ward and intensive care unit (ICU) and used the results to implement cleaning and disinfection interventions. The Cleveland VA Medical Center is a 215-bed hospital with a 22-bed COVID-19 ward and 8-bed COVID-19 ICU. The ICU includes 8 beds for care of non-COVID-19 patients, but with separate primary nursing and physician teams. COVID-19 patients are restricted to their rooms unless they must leave for procedures. Dedicated environmental services personnel are assigned to clean COVID-19 rooms on the ward and in the ICU, and policies and procedures are the same for both units. The study was approved by the Cleveland VA Medical Center Institutional Review Board. We conducted 3 point-prevalence environmental surveys over 5 weeks. Premoistened CLASSIQSwabs with universal transport medium (Copan Diagnostics, Murrieta, CA) were used to sample surfaces in COVID-19 rooms, on the COVID-19 wards outside COVID-19 rooms, and from 2 non-COVID-19 wards. In patient rooms, sites included high-touch surfaces (5 × 20-cm areas of the bed rail and bedside table), floors (5 × 20-cm areas), and socks of COVID-19 patients. Outside patient rooms, sites sampled included portable equipment, nursing stations (eg, telephones, countertops, computers), floors, and shoe soles of personnel. Samples were collected in the late afternoons. The specimens were tested in the Cleveland Clinic Foundation's clinical laboratory using the Centers for Disease Control and Prevention's SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) test. 7 Only positive test results were included in the analysis. A detailed description of the testing methods is included as Supplementary Material (online). At the time of the initial point-prevalence survey, a detergent was used for floors, a sodium hypochlorite disinfectant was used daily and after discharge for nonfloor surfaces in patient rooms, and a hydrogen peroxide disinfectant was used by nursing and environmental services staff for nonfloor surfaces outside patient rooms. Daily disinfection of surfaces in patient rooms was performed in the morning. After review of initial results, a quaternary ammonium-based disinfectant was substituted for the detergent for floors; the second point-prevalence survey occurred 2 weeks after the product substitution. After review of the second set of results, a protocol for increased frequency and thoroughness of cleaning and disinfection of floors was implemented, including intermittent use of a disinfectant containing 2,500 ppm sodium hypochlorite. The third set of samples was collected 1 week after the protocol change. The Fisher exact test was used to compare proportions. The nonparametric Mann-Kendall test was used to detect trends in the frequency of contamination. All analyses were performed using R version 3.5.1 statistical software (The R Foundation for Statistical Computing, Vienna, Austria). In total, 150 sites were sampled: 55 samples inside COVID-19 rooms, 71 samples on the COVID-19 units outside COVID-19 rooms, and 24 samples from areas outside the COVID-19 ward. The frequency of contamination at all sites inside COVID-19 patient rooms did not differ for the 3 periods (P > .05) (Fig. 1) . Overall, contamination was more common on floors than on high-touch surfaces, but the difference was not statistically significant: 6 of 18 (33.3%) versus 3 of 19 (15.8%) (P = .27). Two rooms sampled after postdischarge cleaning had negative results. Figure 2 shows the frequency of contamination on the COVID-19 wards outside of COVID-19 rooms. Trend analysis demonstrated a significant reduction in contamination of all sites from period 1 through period 3 from 36.4% to 20.0% to 3.4% (P = .007). One non-COVID-19 room in the ICU had floor contamination during the initial survey. All 26 samples from high-touch surfaces and portable equipment were negative. All 24 samples collected outside the COVID-19 units were negative, including 3 nursing stations and 21 floor samples including in the hallways exiting the COVID-19 units, non-COVID-19 ward hallways, and elevators. Cycle threshold values were available for the first sampling period. The mean cycle thresholds for the N1, N2, and N3 targets were 30.6 (range, 28.1-33.6), 31.1 (range, 28.7-34.7), and 30.1 (range, 29.6-30.9), respectively. Our results are consistent with previous reports of frequent SARS-CoV-2 nucleic acid contamination in rooms of COVID-19 patients. 4 In contrast to some recent reports, 5,6 we did not detect contamination on high-touch surfaces or portable equipment outside COVID-19 patient rooms. However, SARS-CoV-2 contamination was common on floors and shoes at the time of the initial survey. Interventions to improve floor cleaning and disinfection reduced contamination of floors and shoes outside COVID-19 rooms. The absence of SARS-CoV-2 nucleic acid on high-touch surfaces and equipment outside of COVID-19 rooms suggests that intensive cleaning protocols and use of PPE can minimize the risk for transfer of SARS-CoV-2 from patient rooms to these surfaces. COVID-19 patients were in contact precautions. Nursing and environmental services personnel performed frequent disinfection of high-touch surfaces and equipment. The frequent floor contamination at the time of the initial point-prevalence survey may be attributable to infrequent cleaning and use of a detergent rather than a disinfectant. In that setting, shoes of personnel may serve as a vector for transfer of SARS-CoV-2 from floors in COVID-19 rooms to floors throughout the unit. The importance of floor contamination in SARS-CoV-2 transmission is uncertain. However, in a simulation study, a benign bacteriophage inoculated on floors in patient rooms disseminated widely to surfaces inside and outside the rooms. 8 Also, high-touch objects in hospitals often contact floors and can serve as a source for hand contamination. 9 Based on these findings, it is reasonable to consider measures to minimize dissemination of SARS-CoV-2 from floors. Our study has some limitations. The PCR assay does not distinguish between viable and nonviable viral particles. In a laboratory study, viable influenza viruses inoculated onto surfaces were recovered for up to 2 weeks, but RNA was detected by PCR for 7 weeks. 10 Recent studies have not recovered viable SARS-CoV-2 from environmental sites with positive PCR results. 6 The study was conducted in 1 hospital, and given the small number of COVID-19 rooms sampled, we were unable to assess the impact of factors such as viral load, patient mobility and symptoms, and level of medical care on contamination. Larger studies are therefore needed in other healthcare facilities. The interventions did not result in reduced contamination of floors inside COVID-19 rooms, possibly due to ongoing shedding of virus particles. Finally, we did not evaluate alternative approaches to reduce dissemination from floors such as use of shoe covers inside COVID-19 rooms. In conclusion, SARS-CoV-2 nucleic acid was frequently detected on floors and high-touch surfaces inside COVID-19 rooms and on floors and shoes outside patient rooms on COVID-19 units. Simple modifications of floor cleaning and disinfection protocols could be effective in reducing floor and shoe contamination. Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: possible role of dry surface contamination Interim infection prevention and control recommendations for patients with suspected or confirmed coronavirus disease 2019 (COVID-19) in healthcare settings Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient Environmental contamination of SARS-CoV-2 in healthcare premises Investigating SARS-CoV-2 surface and air contamination in an acute healthcare setting during the peak of the COVID-19 pandemic in London Centers for Disease Control and Prevention Division of Viral Diseases. 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel. US Food and Drug Administration website Evaluation of hospital floors as a potential source of pathogen dissemination using a nonpathogenic virus as a surrogate marker Are hospital floors an underappreciated reservoir for transmission of health care-associated pathogens? Persistence of influenza on surfaces Acknowledgments. We thank the clinical and environmental management services personnel at the Cleveland VA Medical Center for their participation in the study.Financial support. This work was supported by a Merit Review grant (no. 1 I01 BX002944-01A1) from the Department of Veterans' Affairs to C.J.D.Conflicts of interest. C.J.D has received research grants from Clorox, Pfizer, and PDI. All other authors report no conflicts of interest relevant to this article.